Visitor and Community
Network Access Point
Service Manual
Release 2.0
http://www.3com.com/
Part No. DSA-3CV1001-02
Published August 2000
Download from Www.Somanuals.com. All Manuals Search And Download.
ABOUT THIS GUIDE
This guide describes the 3Com® Visitor and Community Network Access
Point Release 2.0, its installation, operation, management, and
troubleshooting.
The NAU (Network Access Unit) name has been changed in release II and
is referred to as Visitor and Community Network Access Point.
This guide is intended for technicians who install or service the VCN
Access Point at customer sites.
If release notes are shipped with your product and the information there
differs from the information in this guide, follow the instructions in the
release notes.
Most user guides and release notes are available in Adobe Acrobat
Reader Portable Document Format (PDF) or HTML on the 3Com
World Wide Web site:
http://support.3com.com/
Conventions
Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons
Icon
Notice Type
Description
Information note Information that describes important features or
instructions
Caution
Information that alerts you to potential loss of data or
potential damage to an application, system, or device
Warning
Information that alerts you to potential personal injury
Download from Www.Somanuals.com. All Manuals Search And Download.
4
CHAPTER : ABOUT THIS GUIDE
Table 2 Text Conventions
Convention Description
Screen displays This typeface represents information as it appears on the
screen.
The words “enter”
and “type”
When you see the word “enter” in this guide, you must type
something, and then press Return or Enter. Do not press
Return or Enter when an instruction simply says “type.”
Words in [ ]
Default values are bracketed in “[ ]”.
Keyboard key names If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+). Example:
Press Ctrl+Alt+Del
Words in italics
Italics are used to:
■
Emphasize a point.
■
Denote a new term at the place where it is defined in the
text.
■
Identify menu names, menu commands, and software
button names. Examples:
From the Help menu, select Contents.
Click OK.
Related
Documentation
The Visitor and Community Based Networking System documentation set
includes the following documents:
■
■
■
■
Visitor and Community Based Networking Access Point Service
Manual
Visitor and Community Based Networking Access Concentrator
Service Manual
Visitor and Community Based Networking Access Point Mounting
Guide
Visitor and Community Based Networking Access Concentrator
Installation Guide
Year 2000
Compliance
For information on Year 2000 compliance and 3Com products, visit the
3Com Year 2000 Web page:
http://www.3com.com/products/yr2000.html
Download from Www.Somanuals.com. All Manuals Search And Download.
Conventions
Related Documentation
1 OVERVIEW
Visitor and Community Network Major Features and Benefits
9
Features
9
Operational Controls 14
Safety Precautions 17
Mounting the VCN Access Point Under a Table 27
Placing the VCN AP on Top of a Table 32
Connecting the VCN AP 33
Operating the VCN Access Point 35
Making a Voice Call 35
Sending and Receiving Data Traffic 36
Sending and Receiving Faxes 36
Download from Www.Somanuals.com. All Manuals Search And Download.
AP Version 42
AP Configuration Menu 55
Closing the Local Management Interface 57
Remote Software Download 58
Procedure 58
Power-on Self Test (POST) 69
Using Front Panel LEDs to Solve Problems 70
Using a PC Terminal Emulator to Solve Problems 74
Ethernet Traffic Counts 75
Summary of Abnormal Indications from Traffic Counts 76
Error Messages 76
Download from Www.Somanuals.com. All Manuals Search And Download.
C LOADING SOFTWARE THROUGH LOCAL ACCESS
3Com Knowledgebase Web Services 97
3Com FTP Site 98
3Com Bulletin Board Service 98
3Com Facts Automated Fax Service 99
Support from Your Network Supplier 99
Support from 3Com 99
Returning Products for Repair 101
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
3COM CORPORATION LIMITED WARRANTY
EMC STATEMENTS
SAFETY STATEMENT
Download from Www.Somanuals.com. All Manuals Search And Download.
OVERVIEW
1
Access Point.
The chapter includes the following topics:
■
■
■
Visitor and Community Network Major Features and Benefits
Visitor and Community Network Applications
VCN Access Point Features
Visitor and
Community
Network Major
Features and
Benefits
A Visitor and Community Network system (VCN) consists of a Access
Concentrator (VCN AC) and up to 24 VCN Access Points (VCN AP)
connected by conventional 4-wire telephone cables.
Features The following are the major features of the Visitor and Community
Network system:
■
The Visitor and Community Network system works over existing
cabling infrastructure and supports all Plain Old Telephone Services
(POTS) while simultaneously providing Ethernet connectivity at speeds
up to 10 Mbps full duplex.
■
The Visitor and Community Network system’s geographic range is 4
kilo feet from an VCN AP to an VCN AC over Category 1 to Category
5 cabling.
■
■
The system supports Ethernet 802.1Q frames transparently. The
maximum supported frame length is 1536 bytes.
The customer can simultaneously engage in two analog toll quality
conversations while sending high speed digital data on the POTS
cable.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
CHAPTER 1: OVERVIEW
■
The system provides fast Internet connectivity and fast corporate
access to end-users.
Benefits The Visitor and Community Network system provides the following
benefits:
■
Use existing wiring for simultaneous voice calls and data connections
without the need for re-wiring. The system enables a customer to use
a telephone extension to place calls while sending and receiving digital
data over the same cable. A second extension over the same
telephone cable can be used to place another call, send faxes, or
connect an analog modem.
The customer receives Internet services more conveniently at faster
speeds. Hotel guests traveling on business can access corporate
Intranets and use e-mail over much more convenient connections than
is currently possible.
The system allows a hotel to provide new data communication
services without forfeiting any POTS revenues.
■
■
The system’s ready-to-use, out-of-the-box installation provides easy
and cost-effective setup. Its non-disruptive installation avoids
complete hotel and floor shut downs.
The system is totally manageable and provides real-time status with
troubleshooting tools. Both the VCN AP and VCN AC support local
management through a terminal emulating computer connection. A
Telnet connection in the Internet or Intranet, supports secure remote
management of the VCN AC in addition to software download.
■
The system presents a low cost of ownership while providing
customers with mutiple services over a single wire, and providing
operators of hotels, residential telecommunications, and office towers
a single manageable network. Its low cost derives from the re-use of
common cabling systems, such as Category 5. It offers low cost
maintenance and flexible tracking capabilities and is readily integrated
with existing hotel and multiple dwelling unit (MDU) billing systems.
■
The Visitor and Community Network system provides a foundation for
future services such as IP telephony. The system offers the capability to
present local advertising and local interest information from a Visitor
and Community Network (VCN) server to users on their computer
monitors. Via a VCN server, Internet, video on demand, and gaming
services can be billed.
The system is easily expanded to cover the required number of rooms.
Download from Www.Somanuals.com. All Manuals Search And Download.
Visitor and Community Network Applications
11
Visitor and
Community
Network
The Visitor and Community Network system serves the following
applications:
■
Multiple Dwelling Units (MDU)
Applications
MDUs include apartment houses and hotels.
Multiple Tenant Units (MTU)
■
MTUs comprise mainly office complexes.
Figure 1 shows a typical MTU/MDU application.
Figure 1 MTU/MDU Visitor and Community Network Systems Application
Existing Phone
Lines
Regular
Phone
Cable
Corporate
Intranet
r
3
c
om
e
w
e
o
n
P
Li
dem
-Mo
Fax-Mode
ET
ERN
ETTHHERNET
VCN AP
Ethernet
Punch-Down
Block
Visitor Based
Networking Servers
Corporate
Server
SuperStack II 1100 Switch
Ethernet
Status
Module
Unit
Firewall
green
=
=
=
enabled, link OK
flashing green
off
disabled, link OK
link fail
1
x
6
x
7
x
1
2
x
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12
10 11 12
P
acket
1
3
5
7
2
Status
4
6
8
13 14 15 16 17 18 19 20 21 22 23 24
13 14 15 16 17 18 19 20 21 22 23 24
Packet
P
o
w
e
r
/
S
e
l
f
T
e
s
t
Status
1
3
x
1
8
x
1
9
x
2
4
x
SuperStack II
Switch 3300
3C16980
Ethernet
24 Ports Concentrator
3
Com
VCN Access
Concentrator
VPN Router
T1 to ISP
Internet
Punch-Down
Block
VPN Router
PBX
Phone Line
PSTN
When personal computer equipped with an Ethernet card is plugged into
the Ethernet port of the VCN AP, the system provides fast internet and
Download from Www.Somanuals.com. All Manuals Search And Download.
12
CHAPTER 1: OVERVIEW
other network services for data transmissions while allowing voice
channels to be used simultaneously.
The VCN AP connects to the VCN AC via a standard copper wire pair. The
VCN AC connects to the analog PBX or local telephone exchange and to
a 10 Base-T switch, e.g. 3Com® VCN Services Switch 10.
After connecting the telephone and the computer to the VCN AP, a
person can send data from his computer and speak on the telephone
simultaneously. An additional telephone extension based on the same
cable remains available for conversation but, does not go through the
VCN AC since the two telephones do not share the same wire pair.
Thus a hotel or a residence that installs Visitor and Community Network is
able to add many more communication services without losing any
existing capability.
The VCN AP joins voice and data channels in the direction of the VCN AC
and separates voice and data channels toward the end user.
The Visitor and Community Network System facilitates intra-campus data
communications over a high speed Local Area Network (LAN), i.e.,
Intranet. If the campus is connected to an ISP, the system enables the
users on the campus to use the Internet.
Existing LAN infrastructure can be extended to locations currently lacking
LAN cabling through the Visitor and Community Network system.
Services that do not need the LAN, for example, voice and fax, continue
to operate normally.
VCN Access Point
Features
The VCN Access Point has the following features:
■
The VCN AP is a network access device that allows a user to have an
Ethernet data connection, available in most PCs and laptops, over a
telephone extension line and simultaneously use the same line for
telephone calls.
■
■
Voice traffic is carried in its native frequency band over the copper pair
wire which connects the VCN AP to the VCN AC.
The VCN AP combines voice and data in the direction of the VCN AC,
which separates voice and data, by sending voice to the analog PBX
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Features
13
and data to the SuperStack II 1100 Switch. The VCN AP also splits
voice and data in the direction from the VCN AC. Data is sent up to 10
Mbps full duplex.
The solution also works with the VCN Services Switch 10 and the
SuperStack II Switch 3300.
■
The user’s Ethernet frames are encapsulated in HDLC frames carried in
VDSL. Voice and data traffic are carried in their respective frequency
ranges in the wire pair that connects the VCN AP to the VCN AC.
Voice traffic, including facsimile and analog modem traffic, are not
modified. Refer to Figure 2.
Figure 2 Transfer of Ethernet Frames to VDSL frames in VCN System
PBX
Ethernet fram e
HDLC fram e
VDSL fram e
Voice calls
Ethernet
fram es
Data frequency
PO TS lines
VCN AC
Ports Concentrator
24
3
Voice frequency
Existing PO TS m etallic pair line
VCN AP
Ethernet
fram es
Ethernet
Voice call
Ethernet
PO TS line
J
J
U
U
H
H
H
H
R
Q
Q
#H
#G
Q
D
D
E
E
O
H
OH
OL
G
G
/
/
#
#
OL
OL
Q
Q
N
N
#
#
2
2
.
.
I
O
D
V
K
QL
J
#
L
V
4[
9[
:[
4
5
[
I
I
#O
L
Q
N
#
I
D
4
4
5
6
6
7
7
8
8
9
:
:
;
;
<
<
4
3
4
4
4
5
3D
6WDWX
3D
6WDWX
F
N
H
W
4
6
5
7
5
9
43
44
45
V
46
47
48
49
4:
4;
4<
53
54
55
56
57
F
N
H
W
8
:
9
;
3R
Z
H
U26
H
O
I #7
H
V
W
46
47
48
49
4:
4;
4<
53
54
55
56
57
V
4
6
[
4
;
[
4
<
[
57[
6X
SH
U6WD
F
N
#,
3C1
69
80
6Z
L
WFK#6
63
3
Ethernet switch
■
The VCN AP supports 4-wire telephone cable. The additional 2 wires
which exist in every telephone cable will remain available for an
additional extension. In telephone sets that have two RJ-11 jacks, the
Download from Www.Somanuals.com. All Manuals Search And Download.
14
CHAPTER 1: OVERVIEW
additional line may be used independently of the VCN AP for
connecting an analog modem or facsimile use.
■
The VCN AP supports remote software download of VCN APs and
VCN Access Concentrators through a special download menu and
through a special network configuration—the VCN AP is connected to
the Ethernet switch directly through the VCN AP Ethernet port. Refer
to Figure 3.
Figure 3 VCN AP Software Download Network Configuration
Existing Phone
Lines
User
Computer
Regular
Phone
Cable
VCN
Access Point
Ethernet
Punch-Down
Block
Ethernet
Software Download
VCN Access Point
VCN Services Switch 10
J
UH
H
H
Q
#
#
#
H
Q
D
D
E
O
H
G
/
#
Q
N
#
#
2
2
.
.
I
DO
V
K
L
Q
J
#
J
U
H
R
Q
I
G
L
V
N
E
D
O
H
LO
G
/
#
OL
Q
N
4[
9[
:[
4
5
[
OL
Q
#
I
4
4
5
5
6
6
7
7
8
8
9
:
;
<
4
4
5
5
3
3
5
5
4
4
4
6
6
4
4
5
5
5
5
7
7
3D
F
N
H
W
4
6
8
:
5
7
9
;
9
:
;
<
5
5
4
5
5
6
W
D
W
X
V
4
6
6
4
7
4
8
4
9
4
:
4
;
4
4
<
5
5
3
3
4
4
3D
F
D
N
W
H
W
3R
Z
H
U2
6
H
O
I#
7
H
V
W
4
4
7
4
8
4
9
4
:
4
;
<
6
W
X
V
4
6
[
4
;
[
4
<
[
5
7
[
6X
S
H
U6WD
F
N
#,
3
C
1
6
9
8
0
6ZLWF
K
#6
6
3
3
24
P
or
t
s
C
o
ncent ator
r
3
VCN Access
Concentrator
Management
Computer
Punch-Down
Block
PBX
Phone Line
Operational Controls This section describes the connectors and LED indicators of the VCN AP.
Figure 4 displays the VCN AP Unit Front View.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Features
15
Figure 4 The VCN AP Unit Front View
Local
Management
Connector
(hidden)
ETHERNET
Fax-Modem
Ethernet
LED
Ethernet
port
Fax-Modem
port
Line LED
Power LED
Table 3 describes the LEDs and connectors on the front panel.
Table 3 The VCN Access Point LEDs and Connectors - Front View
Item
Type
State
Used to
Ethernet LED
Green
Indicate connection of the VCN AP to a PC
Connect the VCN AP to a PC
Ethernet RJ-45
-
-
Fax-
RJ-11 port
Connect a fax machine or a fax modem of a PC
for sending/receiving faxes or making dial-up
data transfers.
Modem
Line
LED
LED
OFF
indicate VCN AP is not connected to the line
Green
Indicate connection of the VCN AP to the VCN
AC
Flashing Indicate data transmission to the VCN AP
in Green
Power
LMI
OFF
Indicate that the VCN AP is not powered
Orange
After 30 seconds, indicate that the
power-on-self-test (POST) failed
Green Indicate that the VCN AP is functional
4-pin
-
Connect the ASCII terminal for monitoring and
troubleshooting.
MiniDin
connector
(hidden)
Figure 5 displays the back panel of the VCN AP.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
CHAPTER 1: OVERVIEW
Figure 5 VCN AP Unit Back Panel
LINE
PHONE
DC-IN
5Vdc
Power
Socket
Telephone
port
Line port
Table 4 describes the connectors on the back panel.
Table 4 The VCN AP Unit LEDs and Connectors - Back Panel
Item
Type
State Used to
Telephone RJ-11 port
-
-
Connect the telephone set
Line
RJ-11 port
Connect the VCN AP to the room
telephone socket
DC-IN
8-pin MiniDIN DC Power
port
-
Connect the AC/DC adapter
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY INFORMATION
2
This chapter provides safety information in English, French and German.
The topics covered in this chapter are:
■
■
■
Safety Precautions
Précautions de sécurité concernant le VCN Access Point
Sicherheitsvorkehrungen für den VCN Access Point
Safety Precautions
The following safety precautions should be taken before installing the
VCN Access Point:
To reduce the risk of electrocution and fire:
■
■
■
■
■
All servicing should be undertaken only by qualified service personnel.
There are no user serviceable parts in the unit.
Do not plug in, turn on or attempt to operate an obviously damaged
unit.
DO not operate the unit in a location where the maximum ambient
temperature exceeds 40 degrees C.
Be sure to unplug the power supply cord from the wall socket before
attempting to remove and/or replace the unit.
The power supply provides for automatic selection of either 100-120
Vac or 200-240 Vac, 60/50 Hz, as indicated on the safety label
adjacent to the power inlet. Ensure that the available voltage supply at
the mains is within one of these two ranges.
■
Use only the special power adapter supplied with the unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
CHAPTER 2: SAFETY INFORMATION
Précautions de
sécurité concernant
le VCN Access Point
Attention: Réduisez les risques d'electrocution et d'incendie
■
Toute intervention sera effectuée uniquement par un personnel
qualifié. L'unité ne comporte pas de pièces à remplacer par
l'utilisateur.
■
■
■
Si l'unité est visiblement endommagée ne pas la brancher au secteur,
ni tenter de la mettre en fonction.
Ne pas faire fonctionner l'unité dans un endroit où la température
ambiante dépasse 40 degrés C.
Assurez vous que vous avez bien débranché le câble d'alimentation
électrique de la prise de courant avant d'essayer de déplacer ou de
remplacer l'unité.
■
Le bloc d'alimentation sélectionne automatiquement la tension
d'entrée (soit 100-120 V soit 200-240 V, alternatif 60/50 Hz) comme
indiqué sur l'étiquette de sécurité apposé à côté de la prise.
Assurez-vous que la tension disponible au secteur se trouve dans la
plage appropriée.
■
N'employez que l'adaptateur d'alimentation fourni avec l'unité.
Sicherheitsvorkeh-
rungen für den VCN
Access Point
Warnung: Um das Risiko eines elektrischen Stromschlages mit möglicher
Todesfolge und eines Feuers zu reduzieren:
■
Alle Wartungsdienste sollten nur von qualifiziertem Wartungspersonal
durchgeführt werden. Die Einheit enthält keine Teile, die der Benutzer
selbst warten kann.
■
Schließen Sie die Einheit unter keinen Umständen an das Stromnetz
an, schalten diese ein oder versuchen diese zu benutzen, wenn die
Einheit klar erkennbar beschädigt ist.
■
■
Bedienen Sie die Einheit nicht, wenn die Temperatur am Standort 40
Grad C übersteigt.
Ziehen Sie den Stromstecker aus der Steckdose, bevor Sie die
Energieversorgung entfernen und/oder austauschen.
Download from Www.Somanuals.com. All Manuals Search And Download.
Sicherheitsvorkehrungen für den VCN Access Point
19
■
Die Energieversorgung wählt automatisch entweder 100-120 V WS
oder 200-240 V WS, 60/50 Hz, wie auf dem Sicherheitsaufkleber
neben der Energiezufuhr angegeben. Gewährleisten Sie, daß die
vorhandene Stromleistung des Hauptstromnetzes innerhalb eines
dieser möglichen Bereiche liegt.
■
Verwenden Sie nur den besonderen Adapter, der mit der Einheit
geliefert wird.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
CHAPTER 2: SAFETY INFORMATION
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING AND OPERATING THE
VCN ACCESS POINT
3
This chapter provides the information about installing, setting up,
powering up and operating the VCN Access Point. The following topics
are described:
■
■
■
Prerequisites for Installation
Installing the VCN Access Point
Operating the VCN Access Point
Prerequisites for
Installation
Before installing the VCN AP, check that you have all the necessary
components and accessories listed in Table 5 and that you have the
required outlets in the room where you will be installing the unit.
The initial communications setup in a room is illustrated in the Figure 6.
Figure 6 Initial Room Communications Setup
Telephone
Socket
The accessories needed for installation are included in the package
provided with the VCN AP set. Prior to carrying out installation, compare
the VCN AP package contents with items listed in Table 5:
Table 5 Unpacking List
NO. Item
Quantity Supplied by
1
2
1
1
3Com
VCN AP
PC (desktop, laptop or
palm held) equipped with
Ethernet Card.
End User
Download from Www.Somanuals.com. All Manuals Search And Download.
22
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
Table 5 Unpacking List (continued)
NO. Item
Quantity Supplied by
3
4
5
6
7
ac/dc adapter
1
1
1
1
1
3Com
Line cable (RJ-11)
3Com
Laptop/PC cable (RJ-45)
FAX cable (RJ-11)
End User or Customer on Request
End User or Customer on Request
4-pin MiniDIN Control
Cable
3Com, for Local Management or
Troubleshooting Only
8
9
Long screws1
3
3
3
1
4
3Com
Short screws1,2
3Com.
10 Wall anchors1
11 Template2
12 Rubber pads3
3Com
3Com, for Installation only
3Com
1
For VCN AP wall installation
2
3
For installing VCN AP under the table
The VCN AC must be installed before the VCN AP. Refer to the Visitor
Installing the VCN
Access Point
The VCN AP may be conveniently mounted on one the following:
■
■
■
a wall, see page 23.
under a table, see page 27.
on top of a table, see page 32.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the VCN Access Point
23
Mounting the VCN To mount the VCN AP on a wall perform the following tasks.
Access Point on a
Wall
1 Apply the paper template to the wall as shown in Figure 7.
Figure 7 Using the Paper Template to Mark the Wall
The partially curved edge of the template corresponds to the curved cover
that is part of the VCN AP front panel.
2 Remove the cover by sliding it downward and then pulling it outward.
See Figure 8.
Figure 8 Removing Curved Cover
Screw hole
ETHERNET
Fax-Modem
All three holes in the VCN AP are plugged.
3 Remove the plugs from the two large holes by prying them out with the
tip of your screwdriver.
4 Remove the plug from the small hole by forcing it out from the bottom
with a pointy instrument (for example a nail).
Download from Www.Somanuals.com. All Manuals Search And Download.
24
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
5 Where the three crosshairs of the template holes intersect, indent the
surface with a sharp tool (for example a nail). See Figure 7.
6 Remove the template.
7 Drill the indented holes with a drill bit of the same diameter as the wall
anchors. See Figure 9.
Note: If the provided anchors are not suited to your wall, you must obtain
and insert suitable anchors that match the diameter of the provided
screws.
Figure 9 Drill Holes for Anchors
8 Insert the three anchors. See Figure 10.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the VCN Access Point
25
Figure 10 Inserting Anchors
9 Drive two of the three long screws provided into the bottommost anchors
to the distance indicated in Figure 11. See Figure 12.
Figure 11 Offset of the Screw Head from the Wall
7/64 in
5 - 3m m
.
2
.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
Figure 12 Driving Screws into the Wall
10 Align the two large holes of the VCN AP (see Figure 13) with the two
already driven screws and insert the screw heads into the holes .
Shift the VCN AP downward so that the screw shanks slip into the slots
and the topmost indented hole is aligned with the VCN AP's small screw
hole.
Figure 13 Screw Holes in the Top of the VCN AP
Large hole
Large hole
Small screw hole
11 Drive the last screw into the wall anchor to the full depth.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the VCN Access Point
27
12 Reinsert the curved cover by reversing the sequence of step 2. See
Figure 14 and Figure 15.
Figure 14 VCN AP without Curved Cover
Figure 15 Placing Curved Cover on VCN AP
Mounting the VCN Two screws support the rear side of the VCN AP and an additional screw
Access Point Under a is used to fasten its front. Find an appropriate location for the VCN AP on
Table the lower surface of a table, as in Figure 16.
Download from Www.Somanuals.com. All Manuals Search And Download.
28
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
Figure 16 Mounting Underneath a Table
VCN AP M ounted
to Underside of
Table Top
To mount the VCN AP under a table, perform the following tasks:
1 Tape the paper template (see Figure 17) to the under side of the table.
Make sure that the straight edge is farthest away from you and the
partially curved edge is nearest to you.
Figure 17 Using the Paper Template to Mark the Table
paper
tem plate
The partially curved edge of the template corresponds to the curved cover
that is part of the VCN AP's front panel.
2 Remove the cover by sliding it downward and then pulling it outward.
See Figure 18.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the VCN Access Point
29
Figure 18 Removing Curved Cover
Screw hole
ETHERNET
Fax-Modem
All three holes in the VCN AP are plugged.
tip of your screwdriver.
4 Remove the plug from the small front hole by forcing it out from the
bottom with a pointy instrument (for example, a nail).
5 Where the crosshairs of the template holes intersect, indent the surface
with a sharp tool (for example, a nail).
6 Remove the template. See Figure 17.
Download from Www.Somanuals.com. All Manuals Search And Download.
30
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
7 Insert two of the three short screws provided into the farthest indented
holes (Figure 19) and drive them to the distance indicated in Figure 20.
Figure 19 Driving Two Screws into the Table
Figure 20 Offset of the Screw Head from the Table
8 Align the two large holes of the VCN AP (see Figure 21) with the two
already driven screws.
9 Insert the screw heads into the holes and then shift the VCN AP forward
so that the screw shanks slip into the slots and the closest indented hole
is aligned with the VCN AP's small screw hole. See Figure 22.
Download from Www.Somanuals.com. All Manuals Search And Download.
32
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
10 Drive the last short screw through the small screw hole and into the
surface full depth. See Figure 23.
Figure 23 Completion of Mounting the VCN AP Under the Table
11 Reinsert the curved cover by reversing the sequence of step 2.
Placing the VCN AP Four rubber pads must be attached to the VCN AP bottom to provide
on Top of a Table stability when the VCN AP is used on top of a table.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the VCN Access Point
33
To mount the VCN AP on top of a table perform the following tasks:
1 Stick the four rubber pads to the bottom of the VCN AP as shown in
Figure 24.
Figure 24 Preparing VCN AP for Table Top Use
Attach Four Rubber Pads
Local
M anagem ent
Rear
Panel
Section
2 Turn the VCN AP over and place it on top of a table near the ac power
and telephone sockets in the room.
Connecting the VCN To enable VCN AP operation, connect the following from the rear of the
AP unit:
■
■
■
VCN AP PHONE port at the front.
Connect an RJ-11 cable from the VCN AP LINE port to the wall
telephone socket.
Connect the ac/dc adapter to the DC-IN port in the VCN AP and to the
ac power socket in the room.
The resulting connections are illustrated in Figure 25.
Download from Www.Somanuals.com. All Manuals Search And Download.
34
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
Figure 25 Preparation of the VCN Access Point
telephone
socket
ac/dc
adapter
ac power
socket
LINE
PHONE
DC-IN
V CN A ccess Point
■
Connect an RJ-45 cable from the user’s PC to the Ethernet port at the
front of the VCN AP. The user’s PC must be equipped with an Ethernet
card. If the user’s PC does not have an Ethernet card installed, the
AP. In such case, the data does not go through the VDSL line and
cannot make use of the 10 Mbps full duplex connectivity.
■
If the telephone set has an additional RJ-11 port, it can be used
independently of the VCN AP for fax or modem.
Power and Line LEDs on the VCN AP front panel are green. Refer to
The VCN AP does not have an ON/OFF switch. The unit is powered on as
soon as it is connected to ac power.
If the LEDs on the VCN AP do not turn green, refer to Appendix A
Troubleshooting, section “Power-on Self Test (POST)”.
Figure 26 illustrates the VCN Access Point-VCN Access Concentrator
network after the VCN AP is installed and a user computer is attached to
the VCN AP. The user has both access to the Public Switched Telephone
Network (PSTN) and a high speed connection to an Internet Service
Provider (ISP) as well as an additional connection to a fax or Modem.
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating the VCN Access Point
35
Figure 26 Communications Access via the VCN AP
Room
VCN
Access Point
m
o
c
3
oewr
P
Lnie
Fax-Modem
ETHERNET
Basement
24 Ports Concentrator
3C10BSO24OA-C
LAN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
24 wire pairs
VCN Access
Concentrator
LINE
POWER
3
Com
ISP / INTERNET
24 wire pairs
24 wire pairs
24 wire pairs
NSP / PSTN
PBX
Punch-Down Blocks
Operating the VCN
Access Point
After the installing and mounting the VCN Access Point it is ready for use.
The VCN AP may be used for the following:
■
■
■
Making a Voice Call
Sending and Receiving Data Traffic
Sending and Receiving Faxes
Making a Voice Call You can make a voice call without connecting the VCN AP to power or to
any front panel connection.
To place a voice call:
1 Check that the telephone port is connected to a telephone set and the
LINE port on the rear of the VCN AP is connected to the wall telephone
socket.
2 Use the telephone set as if it were connected directly to the wall socket.
Download from Www.Somanuals.com. All Manuals Search And Download.
36
CHAPTER 3: INSTALLING AND OPERATING THE VCN ACCESS POINT
3 If the telephone set has an additional RJ-11 port, it can be used
independently of the VCN AP for fax. Connect an RJ-11 cable between
the fax machine or the PC fax modem to the PC RJ-11 port on the VCN
AP.
Sending and To send or receive data traffic:
Receiving Data Traffic
1 Connect a RJ-45 cable between the Ethernet port and the PC Ethernet
card.
NOTE: No password or account number specific to the local ISP is
needed, however, your normal log-in procedure should be observed,
including access privileges like user ID, password, etc.
2 Run your network application: browser, e-mail etc.
Sending and You can make a fax call without connecting the VCN AP to power.
Receiving Faxes
To send or receive faxes:
1 Connect a RJ-11 cable between the fax machine or the PC fax modem
and the VCN AP Fax-Modem port.
2 Use the fax machine and the telephone set in accordance with the fax
machine user manual.
3 If the telephone set has an additional RJ-11 port, it can be used
independently of the VCN AP for fax or modem. Connect an RJ-11 cable
between the fax machine or the PC fax modem to the PC RJ-11 port.
Download from Www.Somanuals.com. All Manuals Search And Download.
USING THE LOCAL MANAGEMENT
ACCESS
4
This chapter describes using the Local Management Access (LMA) and
computer connected to the LMA port on the VCN Access Point. The
terminal is used for monitoring and problem solving. Remote software
Access Concentrator from a remote terminal.
The following topics are described:
■
■
■
Using the Management Terminal
VCN Access Point Menus
Remote Software Download
Using the
Management
Terminal
A computer with terminal emulation software provides the user interface
to the local management of the VCN Access Point.
Management For service and maintenance, use a PC equipped with a terminal
Terminal application capable of 115,200 bps serial communication with a VCN AP.
Requirements Refer to Appendix E Terminal Emulation Settings.
The cable for connecting the management computer has a DB 9 pin
connector for the computer and a 4 pin MiniDIN connector for the VCN
AP LMA port. If you do not have the cable, contact your 3Com
representative. Refer to Appendix D Pin Assignments for LMA Cable for a
detailed description of the cable and the LM connectors.
Download from Www.Somanuals.com. All Manuals Search And Download.
38
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Connecting the PC Perform the steps below to connect the PC to the LMA port:
Terminal Emulator
1 Remove the cover from the LMA section of the VCN AP as in the figure
below.
Figure 27 LMA Section of the VCN Access Point
Screw hole
ETHERNET
Fax-Modem
Local
Management Port
2 Connect the LMA port to the PC serial port (COM1 or 2) with the cable
provided you; if you do not have the cable, contact 3Com. Plug the end
of the cable with the a four-pin MiniDIN connector into the VCN AP LMA
port.
VCN Access Point
Menus
This section describes the menus.
Summary and This section provides a menu hierarchy to describe the structure of the
Structure of the menu system and a menu summary to help the network administrator
Menus use the management system efficiently.
The chart in Figure 28 summarizes the menu hierarchy. The abbreviations
next to the menu names are suggestions for how the menus are used.
Most of the menus labeled D are not described further in this chapter
since they are used mainly by developers for debugging. The debug
menus for performing loopbacks are described since loopbacks can be
used by network administrators to solve problems.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
39
Figure 28 Menu Hierarchy
Change
Work Mode
P
Login Process
P
Set Normal Mode
P
M
D
Management
Menu
Ethernet
Menu
Ethernet Status
Set Internal
Loopback Mode
M
Access Point Main Menu
Traffic Counters
Reset Counters
Learning Table
P
D
Set External
Loopback Mode
P
C
D
D
D
Debug Menu
Test Control
Set Full Duplex
Mode
M
D
Change
Work Mode
HDLC Menu
D
Set Normal Mode
D
P
M
P
Set Internal
Loopback Mode
HDLC Status
D
Flash Actions
Tasks Info Menu
Traffic Counters
Reset Counters
S
P
Operation
Mode Selector
S
D
Reset Board
P
Reset All Counters
C
Set Ethernet Half/Full Duplex Mode
Set VLAN ID for Management
C
C
KEY
AP Configuration
Configuration
C
C
C
Change Password
M Monitoring system
operation and problem
reporting
Set to Factory Defaults
D
D
Read BCM6010 register
Write BCM6010 register
I2C control
M
M
P
QAM Channel Status
P
S
D
Problem Solving
VDSL Control
AP Version
Software Download
D
D
Debug, for developers
use only
VDSL print
Table 6 provides a summary of the line card menus, the submenus and
the corresponding number sequence. Click a menu or submenu name to
receive more information.
After typing each number in the number sequence press the <Enter> key.
Download from Www.Somanuals.com. All Manuals Search And Download.
40
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Table 6 Number Sequence Corresponding to Submenus
Number
Sequence
Menu Name
Submenu
Access Point Main Menu
AP Version
1
Management Menu
The Ethernet Menu
3
31
Ethernet Traffic Counters
Ethernet Status
3 1 1
3 1 2
3 1 3
3 1 4
3 2
Reset Counters
Change Ethernet Work Mode Menu
The HDLC Menu
HDLC Traffic Counters
HDLC Status
3 2 1
3 2 2
3 2 3
3 2 4
3 4
Reset Counters
Change HDLC Work Mode
Reset All Counters
Reset the Board
VDSL Menu
3 5
4
VDSL QAM Channel Status Report
4 1
AP Configuration Menu
7
Set VLAN ID for Management
Set Ethernet Half/Full Duplex Mode
Change Password
7 1
7 2
7 3
Set to Factory Defaults
7 4
Login After connecting the management terminal to one of the LMA ports 2
through 24, press any key. The login dialog appears:
Login:
Type your Login ID and press <Enter>.
Password:
Type your password and press <Enter>.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
41
The default login is admin; the default password is null—just press
<Enter>.
If you forget your password, contact technical support. Refer to
Appendix F Technical Support.
login was unsuccessful, the following message appears:
Login incorrect
Access Point Main In reconnecting to the VCN AP, the last used menu often appears. In most
Menu menus, except where indicated, the option labeled 0is for returning to a
higher level menu (Figure 29).
Figure 29 Return to Previous Menu Option
0. Return to previous menu
Press any key to view the Access Point Main Menu on the terminal screen.
If another menu appears, type 0(zero) and press <Enter> repeatedly until
the Access Point Main Menu appears.
Figure 30 VCN AP Main Menu
Access Point Main Menu
----------------------
1. AP Version
2. Debug Menu
3. Management Menu
4. VDSL control
5. Test control
6. Flash actions
7. AP Configuration
8. Software Download Menu
0. Exit
Please enter your choice:
Download from Www.Somanuals.com. All Manuals Search And Download.
42
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
AP Version Confirm VCN AP functionality by checking the software and hardware
versions and dates.
1 To check the software version, enter 1In the Main Menu (Figure 30,
page 41). The following screen appears:
Figure 31 Version Screen
System Display
--------------
HW Version:
SW Version:
SW Date:
1.0
3.5
Jul 23 2000,
15:56:28
SW Time:
Press ENTER to continue ...
2 Press <Enter> to return to the Main Menu.
Management Menu To display the Management Menu, type 3in the Main Menu and press
<Enter>. The Management Menu appears:
Figure 32 VCN AP Management Menu
Management Menu
----------------
1. Ethernet Menu
2. HDLC Menu
3. Tasks Info Menu
4. Reset All Counters
5. Reset Board
0. Return To Previous Menu
Please enter your choice:
The Ethernet Menu To view the Ethernet Menu:
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
43
1 In the VCN AP Main Menu enter 3.
2 In the Management Menu, enter 1. The Ethernet Menu appears
Figure 33 Ethernet Menu.
Ethernet Menu
-------------
1. Traffic Counters
2. Ethernet Status
3. Reset Counters
4. Change Work mode
5 Learning table
0. Return to previous menu
Please Enter your choice:
Ethernet Traffic Counters
The Ethernet traffic counters count normal frames and errored frames
transferred between the user’s PC and the VCN AP.
Download from Www.Somanuals.com. All Manuals Search And Download.
44
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
To check the Ethernet traffic counters, type 1 in the Ethernet Menu and
press <Enter>; the Ethernet Traffic Counters screen appears:
Figure 34 Ethernet Traffic Count Screen
Ethernet traffic counters
-------------------------
transmit counters
Tx frames
Tx error
Discarded
- 6107
- 0
- 0
Receive counters
Rx frames
Crc errors
Discarded
- 159
- 0
- 0
Alignment error - 0
Overrun
Collision
Frame too long
- 0
- 0
- 0
Frame too short - 0
press <Enter> to continue
Ethernet Status
To check Ethernet status, press 2in the Ethernet Menu; the Ethernet
Status screen appears:
Figure 35 Ethernet Status Screen
Ethernet Status
---------------
Scc channel numbers
Work Mode
Transmit enable
Receive Enable
Heartbeat checking
Retry Limit
- 2
- normal mode
- yes
- yes
- no
- 15
Maximum length of rx frame - 1522
Maximum length of tx frame - 64 bytes
press <Enter> to continue...
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
45
Reset Counters
To reset Ethernet counters:
1 In the Ethernet Menu, type 3and press <Enter>. The following message
appears:
Do you want to proceed (Y/[N])? :
appears:
The action has been done !
Learning Table
To view the MAC and IP addresses of the user’s PC, type 5 in the Ethernet
Menu and press <Enter>. If a PC is connected, the Learning Table in
Figure 36 appears.
Figure 36 A Typical MAC Address Display
Learning table:
---------------
MAC address: 00-60-08-BC-F7-7F
IP address : 191.28.68.25
Press <Enter> to continue.......
If a PC is not connected, the message in Figure 37 appears.
Figure 37 Station not Connected Message
Learning table:
---------------
Station not connected
press <Enter> to continue...
Change Ethernet Work Mode Menu
To change the Ethernet loopback mode or the duplex mode, use the
Change Work Mode Menu. In the Ethernet Menu, type 4and press
<Enter>. The options in Figure 38 appear.
Download from Www.Somanuals.com. All Manuals Search And Download.
46
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 38 Change Work Mode Menu
Change Work Mode Menu
---------------------
Current Working Mode of Ethernet: Normal Operation
1. Set Normal Mode
2. Set Internal Loopback Mode
3. Set Extenal Loopback Mode
4. Set Full Duplex Mode
0. Return to Previous Menu
Please enter your choice:
In the Change Work Mode Menu, the current working mode is shown to
be one of:
■
Normal Operation
Internal Loopback Mode
■
■
■
External Loopback Mode
Full Duplex Mode
The full duplex mode is displayed if a previous operation changed the
mode to full duplex.
Refer to Setting Duplex Mode, on page 47, for changing the duplex
mode.
Setting Internal Loopback Mode
To set internal loopback mode, type 2and press <Enter>. The message
appears:
This action will change the working mode of Ethernet!
Do you want to proceed (Y/[N])? :
To confirm type y; to discard, type n; and and press <Enter>.
When you proceed, the message appears:
Action has been done.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
47
When you discard the operation, the message appears:
The action has been canceled
Setting External Loopback Mode
To set external loopback mode, type 3and press <Enter>. The message
appears:
This action will change the working mode of Ethernet!
Do you want to proceed (Y/[N])? :
To confirm type y; to discard, type n; and and press <Enter>.
When you proceed, the message appears:
Action has been done.
When you discard the operation, the message appears:
The action has been canceled
Setting Normal Mode
To set normal mode, type 1and press <Enter>. The message appears:
This action will change the working mode of Ethernet!
Do you want to proceed (Y/[N])? :
To confirm type y; to discard, type n; and and press <Enter>.
When you proceed, the message appears:
Action has been done.
When you discard the operation, the message appears:
The action has been canceled
Normal mode is both lack of loopbacks and half duplex operation.
Setting Duplex Mode
To change the duplex mode to full, type 4in the Change Work Mode
Menu, and press <Enter>. The messages appear:
Download from Www.Somanuals.com. All Manuals Search And Download.
48
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
This action will change the working mode of Ethernet!
Note: the change will NOT be saved after reset.
For changing and saving use the configuration menu
Do you want to proceed (Y/[N])? :
To confirm type y; to discard, type n; and and press <Enter>.
When you proceed, the message appears:
Action has been done.
When you discard the operation, the message appears:
The action has been canceled
The HDLC Menu To view the HDLC Menu,
1 In the Main Menu type 3 and press <Enter>. The Management Menu
appears (Figure 32).
2 In the Management Menu type 2 and press <Enter>. The HDLC Menu
appears (Figure 39).
Figure 39 HDLC Menu.
HDLCMenu
----------
1. Traffic Counters
2. HDLC Status
3. Reset counters
4. Change Work mode
O. Return to previous menu
Please Enter your choice... :
HDLC Traffic Counters
The HDLC traffic counter counts normal frames and errored frames over
the common telephone and data line, thus indicating the behavior of the
connection between the VCN AP and the VCNAC.
To check the HDLC traffic counters, type 1 in the HDLC Menu and press
<Enter>; the HDLC Traffic Counters Screen appears (Figure 40).
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
49
Figure 40 HDLC Traffic Counters Screen
HDLC Traffic Counters
---------------------
Transmit counters
Tx frames
Retransmissions
Tx errors
Discards
- 3
- 0
- 0
- 0
Receive counters
Rx frames
Crc errors
- 6
- 10219
Discards
Abort sequences
Overruns
- 0
- 23017
- 0
Not mine
- 0
- 0
- 0
- 39201
Frames too long
Dpll errors
Frames not aligned
Press ENTER to continue ...
Reset Counters
To reset HDLC counters:
1 In the HDLC Menu, type 3 and press <Enter>. The message appears:
Do you want to proceed(Y/[N])? :
2 Type yand press <Enter> to perform the reset.
HDLC Status
To check HDLC status, enter 2in the HDLC menu; the HDLC Status screen
appears:
Download from Www.Somanuals.com. All Manuals Search And Download.
50
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 41 HDLC Status Screen
HDLC Status
------------
Scc channel numbers
- 3
Work Mode
Transmit enable
Receive Enable
- normal mode
- yes
- yes
Maximum length of rx frame- 1518
press <Enter> to continue...
Change HDLC Work Mode
To change the HDLC loopback mode, use the Change Work Mode Menu.
In the HDLC Menu, type 4and press <Enter>. The options in Figure 42
appear.
Figure 42 Change HDLC Work Mode Menu
Current Working Mode of HDLC: Normal Operation
1. Set Normal Mode
2. Set Internal Loopback Mode
0. Return to Previous Menu
Please enter your choice:
In the Change Work Mode Menu, the current working mode is shown to
be one of:
■
Normal Operation
Normal operation is lack of loopbacks.
Internal Loopback Mode
■
Setting Internal Loopback Mode
To set internal loopback mode, type 2and press <Enter>. The message
appears:
This action will change the working mode of HDLC!
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
51
Do you want to proceed (Y/[N])? :
To confirm type y; to discard, type n; and and press <Enter>.
When you proceed, the message appears:
Action has been done.
When you discard the operation, the message appears:
The action has been canceled
Setting Normal Mode
To set normal mode, type 1and press <Enter>. The message appears:
This action will change the working mode of HDLC!
Do you want to proceed (Y/[N])? :
To confirm type y; to discard, type n; and and press <Enter>.
When you proceed, the message appears:
Action has been done.
When you discard the operation, the message appears:
Normal mode is lack of loopbacks.
Reset All Counters To reset all counters, perform the following steps:
1 In the Main Menu, type 3and press <Enter>; the Management Menu
appears.
2 In the Management Menu, type 4 and press <Enter>; a confirmation
message appears. The counters have been reset.
Reset the Board To reset the VCN AP, type 5in the Management Menu (Figure 32) and
press <Enter>; the messages in Figure 43 appear:
Figure 43 Reset Board Confirmation
This action will reset the whole board
Do you want to proceed (Y/[N])? :
Download from Www.Somanuals.com. All Manuals Search And Download.
52
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
To reject, press <Enter> or type nand press <Enter>. The Management
Menu reappears.
To proceed type yand press <Enter>; the message appears:
The system is going down...
The Operation Mode Selector Menu (Figure 44) appears.
Figure 44 Operation Mode Selector Menu
********************************************************
3Com NCD. (C)
10Base-S Boot loader V2.00
Date: Jun 15 1999, Time: 16:13:31
CPE modem Operation Mode Selector.
Enter:
D - for Debug operation
OR
F - for SW execution from the Flash OR
C - for MAC address programming.
********************************************************
If this menu is ignored for 5 seconds, execution from the flash begins and
the messages in Figure 45 through Figure 47 appear. This is the default
option F.
Option Cis for entering the MAC address. This is normally performed in
the factory.
Option Dis for debugging. This option is for developers only.
Option Sis for downloading software through the LMA port. For more
information see Appendix C Loading Software Through Local Access.
To use an option, type its letter.
To continue with the reset operation without performing the other
options, do one the followin steps:
■
Wait 5 seconds.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
53
■
Enter F.
Figure 45 Reset messages
******************************
SW is being executed from Flash! Please wait...
******************************
SW image is being copied to the SDRAM
Entering BOOT_image_get!
Read FLASH start!
Read address is - 2880008
Read FLASH OK!
SW image validation passed!
SW image is being executed!
*****************************
Figure 46 Start of Software Execution
Start executing main!
Watchdog initialized OK !
Figure 47 Self-test Messages
HDLC selftest passed!
Ethernet selftest passed!
I2C selftest passed!
VDSL selftest passed!
MNG task created!
MNG task started!
LED task created!
LED task started!
DWN task created!
DWN task started!
LMA task created
LMA task started
Then the Login prompt appears.
VDSL Menu To view the VDSL Menu, type 4 in the Main Menu and press <Enter>; the
VDSL Menu appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
54
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 48 VDSL Menu
.
VDSL Menu
---------
1. QAM channel status
2. Read BCM6010 register
3. Write BCM6010 register
4. I2C control
5. VDSL print
0. Return to previous menu
Please Enter your choice:
VDSL QAM Channel Status Report
To check the VDSL parameters, enter 1in the VDSL Control Menu; the
QAM Channel Status report appears:
Figure 49 VDSL QAM Channel Status Report
QAM Channel Status
------------------
QAM status:
In lock
VDSL restarts:
VDSL warm starts:
1
0
Downstream parameters
DS Symbol rate:
DS Constellation:
DS Bit rate:
1.964 Mbaud
2^5
9.820 Mbps
40.30 dB
SNR Estimate:
Upstream parameters
US Symbol rate:
US Constellation:
US Bit rate:
4.910 Mbaud
2^2
9.820 Mbps
Press ENTER to continue ...
Figure 49 contains the following information:
■
QAM Status: In lock—the line to the VCN Access Concentrator (VCN
AC) is connected.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
55
The alternate state is Out of lock—the line to the VCN AC is not
connected.
■
■
■
Restarts, the number of times the line to the VCN AC undergoes a
cold restart. A cold restart occurs when there is a prolonged break in
the line.
Warm restart, a restart using information that existed the previous
time the link was operational. A warm start occurs when the line is
briefly disconnected or line noise occurs over a period of time.
SNR, signal to noise ratio.
AP Configuration To configure the VCN AP, type 7in the Access Point Main Menu and
Menu press <Enter> ; the following options appear (Figure 50):
Figure 50 The AP Configuration Menu
AP Configuration Menu
----------------------
Current VLAN ID for Management:
Current Ethernet mode:
None
Half Duplex
1. Set VLAN ID for Management
2. Set Ethernet Half/Full Duplex Mode
3. Change Password
4. Reset to Factory Defaults
0. Return to Previous Menu
Please enter your choice: 0
Set VLAN ID for Management
To set the VLAN ID perform the following steps:
1 In the AP Configuration Menu enter 1.
2 Enter the VLAN ID number or enter 0for none; a note appears as well as
a confirmation, as shown in Figure 51.
Download from Www.Somanuals.com. All Manuals Search And Download.
56
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 51 Setting VLAN ID Message Screen.
Please enter your choice: 1
Note: In a topology with VCN Concentrator, this setting
may override the concentrator agent settings. For more
information please refer to the service manual.
Enter VLAN ID (1-4094, 0 for none) [none]: 2
Action has been done
Set Ethernet Half/Full Duplex Mode
To set Ethernet half/full duplex mode, perform the following steps:
1 In the AP Configuration Menu enter 2.
2 Enter the desired mode; a confirmation message appears.
Action has been done.
Change Password
To change the password, do as follows:
1 In the AP Configuration Menu, enter 3.
2 You are prompted to enter the old password followed by the new
password and a confirmation, as in Figure 52:
Enter the old password:
Enter the new password (up to 8 characters):
Confirm new password (up to 8 characters):
The password was changed and saved in a non-volatile memory
If you forget your password, contact technical support. Refer to
Appendix F Technical Support.
Download from Www.Somanuals.com. All Manuals Search And Download.
VCN Access Point Menus
57
Set to Factory Defaults
To set VCN AP to factory defaults perform the following steps:
1 In the AP Configuration Menu, type 4and press <Enter>; a warning
message that the action will set the system to their default value appears:
This action will return the system parameters to their
default values!
Do you want to proceed (Y/[N])?:
2 Type yand press <Enter>; the system is set to factory default. The
following messages appear:
The factory’s default settings were written to the
non-volatile memory
Note: some of the changes will take effect after reset
Closing the Local When you are finished using the local management menus, exit your
Management terminal emulation program and disconnect your personal computer
Interface from the Local Management port.
Download from Www.Somanuals.com. All Manuals Search And Download.
58
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Remote Software
Download
This section describes the remote software downloading procedure.
Overview The VCN Access Point is an Ethernet over VDSL modem that combines
the transmission of voice and data in the direction of the VCN Access
Concentrator and separates voice and data in the direction from the VCN
AC towards the user.
A VCN AP can be directly attached to the Ethernet switch for the purpose
of downloading a software release update to other VCN APs and to the
line cards in the VCN ACs. In this application, the VCN AP is connected
directly to the Ethernet network through the Ethernet port and sends and
receives data only. The user is connected to the VCN AP LMA port and
operates a Software Download Menu to perform the software download.
Requirements The following are the requirements for downloading software:
■
■
■
■
The downloading VCN AP software is version 3.5 or later.
The software of the receiving VCN AC LCs is version 3.5 or later.
The software of the recieving VCN APs is version 3.0 or later.
The remaining requirements for the VCN APs and VCN AC are the
same as for all operational units.
If the software requirements are not met, then local downloading
procedures must be used. For the VCN AC, refer to Visitor and
Community Based Networking Access Concentrator Service Manual,
Chapter 3, the section Loading a New Software Release Through the
LMA.
For the VCN AP, refer to Appendix C, Loading Software Through Local
Access in this manual.
Procedure
Recommendation: Prior to performing remote software download,
configure your switch. Perform the procedure in Visitor and Community
Network Access Concentrator Service Manual, Managing the VCN Access
Concentrator, section Configuring the Ethernet Switch for the VCN
Access Concentrator.
To use the VCN AP to download software perform the following steps:
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Software Download
59
Downloading Software to the LCs in the VCN AC
1 Remove the cover of the LMA section of the VCN AP to reveal the LMA
port, as shown in page 38, Figure 27.
2 Connect the management computer to the VCN AP LMA port.
3 Using RJ-45 connectors, connect the Ethernet port of the VCN AP to an
Ethernet switch 10BaseT port; refer to Figure 53. Refer to Figure 54 for
the network configuration.
Recommendation: Attach the downloading VCN AP to port
■
■
■
■
26 in the VCN Services Switch 10.
26 in the the SuperStack II Switch 1100.
24 in the VCN Services Switch 100.
24 in the SuperStack II Switch 3300.
Figure 53 The VCN Service Switch 10 Front Pane
green
flashing green
off
=
=
=
enabled, link
disabled, link OK
link fail
O
K
6x 7x
18x 19x
12x
24x
1x
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12
10 11 12
P acket
S tatus
P acket
S tatus
1
3
5
7
2
4
6
8
TCV
R
13 14 15 16 17 18 19 20 21 22 23 24
13 14 15 16 17 18 19 20 21 22 23 24
25 26 P acket
25 26 S tatus
Power/Self Test
13x
25x 26x
VCN Services
Switch 10
3 C V 2 01 0
Download from Www.Somanuals.com. All Manuals Search And Download.
60
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 54 Software Download Network Configuration
Existing Phone
Lines
User
Computer
Regular
Phone
Cable
VCN
Access Point
Ethernet
Punch-Down
Block
Ethernet
Software Download
VCN Access Point
VCN Services Switch 10
J
UH
H
H
Q
#
#
#
H
Q
D
D
E
O
H
G
/
#
Q
N
#
#
2
2
.
.
I
DO
V
K
L
Q
J
#
J
U
H
Q
G
L
V
E
O
H
LO
<
G
/
#
OL
Q
N
4[
9[
:[
4
5
[
R
I
OL
Q
N
#
I
D
4
4
5
5
6
6
7
7
8
8
9
:
;
4
4
5
5
3
3
5
5
4
4
4
5
3D
F
N
H
W
4
6
8
:
5
7
9
;
9
:
;
<
5
5
4
5
5
4
6
6
4
5
5
5
7
7
6
W
D
W
X
V
4
6
6
4
7
4
8
4
9
4
:
4
;
4
4
<
5
5
3
3
4
4
3D
F
D
N
W
H
W
3R
Z
H
U2
6
H
O
I#
7
H
V
W
4
4
7
4
8
4
9
4
:
4
;
<
6
W
X
V
4
6
[
4
;
[
4
<
[
5
7
[
6X
S
H
U6WD
F
N
#,
3
C
1
6
9
8
0
6ZLWF
K
#6
6
3
3
24
P
or
t
s
C
o
ncent ator
r
3
VCN Access
Concentrator
Management
Computer
Punch-Down
Block
PBX
Phone Line
4 In the VCN AP Main Menu (Figure 30) type 8, and press <Enter> for the
Software Download Menu.
A warning appears, followed by a prompt asking if you want to proceed
(Figure 55).
Figure 55 Remote software Download Warning and Prompt
*Choosing this menu will discontinue normal VCN AP operation.
*
*VDSL line will be stopped. Reset board to renew VDSL connection*
*****************************************************************
Do you want to proceed (YES/[NO])? :
5 To proceed, type yesand press <Enter>; the Software Download Menu
(Figure 56) appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Software Download
61
Figure 56 Software Download Menu
Software Download Menu
----------------------
1. AP Version
2. Download LC
3. Download AP
4. LC Downloading State
5. AP Downloading State
6. Change the VLAN Id for Downloading
7. Reset Board
Please enter your choice:
6 To download software to LCs do as follows:
a Check the VLAN IDs of the VCN AP and the VCN AC.
b To change the VLAN ID of the AP to make it the same as the AC, type
6in the Software Download Menu and press <Enter>. The following
dialog appears:
Current VLAN ID for downloading:
Please enter new VLAN ID (1 - 4094, 0 for none):
c Enter the AC VLAN ID and press <Enter>. The message appears:
Action has been done.
Software Download will not occur if the VCN AP is not in the same VLAN
as the VCN AC.
d In the Software Download Menu, type 2and press <Enter>. The LC
Downloading State Table appears (Figure 57).
Download from Www.Somanuals.com. All Manuals Search And Download.
62
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 57 The LC Downloading State Table
LC downloading state table
------------------------------------------------------
| LC | Downloading || LC | Downloading |
| number |
status
|| number |
status
|
------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
|
|
1 | Not downloaded ||
2 | Not downloaded ||
3 | Not downloaded ||
4 | Not downloaded ||
5 | Not downloaded ||
6 | Not downloaded ||
7 | Not downloaded ||
8 | Not downloaded ||
9 | Not downloaded ||
10 | Not downloaded ||
11 | Not downloaded ||
12 | Not downloaded ||
13 | Not downloaded |
14 | Not downloaded |
15 | Not downloaded |
16 | Not downloaded |
17 | Not downloaded |
18 | Not downloaded |
19 | Not downloaded |
20 | Not downloaded |
21 | Not downloaded |
22 | Not downloaded |
23 | Not downloaded |
24 | Not downloaded |
------------------------------------------------------
Enter LC number (1 - 24, 0 for all, R for return):
e At the end of the LC Downloading State Table, do one of the
following:
■
<Enter>.
(Figure 58).
■
■
Type 0and press <Enter> to download the software to all LC cards.
The downloading messages and the downloading results table appear
(Figure 58).
Type r and press <Enter> to cancel.
The VCN AP Software Download Menu (Figure 56) reappears.
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Software Download
63
Figure 58 LC Downloading Results
Begin sending version...
Sending version complete
Waiting for acknowledge...
Downloading complete.
Downloading complete. See results in the table:
------------------------------------------------------
| LC | Downloading || LC | Downloading |
| number |
status
|| number |
status
|
------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
|
|
1 | Successful
2 | Successful
3 | Successful
4 | Successful
5 | Successful
6 | Successful
7 | Successful
8 | Successful
9 | Successful
10 | Successful
11 | Successful
12 | Successful
||
||
||
||
||
||
||
||
||
||
||
||
13 | Successful
14 | Successful
15 | Successful
16 | Successful
17 | Successful
18 | Successful
19 | Successful
20 | Successful
21 | Successful
22 | Successful
23 | Successful
24 | Successful
|
|
|
|
|
|
|
|
|
|
|
|
------------------------------------------------------
Press ENTER to continue ...
Download from Www.Somanuals.com. All Manuals Search And Download.
64
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Downloading Software to VCN APs:
To download software to VCN APs do as follows:
1 Perform step 1 through step 5 above.
2 Check the VLAN IDs of the downloading VCN AP and the receiving VCN
APs.
3 To change the VLAN ID of the AP to make it the same as the receiving
VCN APs, type 6in the VCN AP Software Download Menu and press
<Enter>. The following dialog appears:
Current VLAN ID for downloading:
Please enter new VLAN ID (1 - 4094, 0 for none):
4 Enter the AP VLAN ID and press <Enter>. The message appears:
Action has been done.
Software Download will not occur if the downloading VCN AP is not in
the same VLAN as the receiving VCN APs.
5 In the Software Download Menu type 3 and press <Enter>. The AP
Downloading State Table appears (Figure 59).
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Software Download
65
Figure 59 AP Downloading State Table
AP downloading state table
------------------------------------------------------
| AP | Downloading || AP | Downloading |
| number |
status
|| number |
status
|
------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
|
|
1 | Not downloaded ||
2 | Not downloaded ||
3 | Not downloaded ||
4 | Not downloaded ||
5 | Not downloaded ||
6 | Not downloaded ||
7 | Not downloaded ||
8 | Not downloaded ||
9 | Not downloaded ||
10 | Not downloaded ||
11 | Not downloaded ||
12 | Not downloaded ||
13 | Not downloaded |
14 | Not downloaded |
15 | Not downloaded |
16 | Not downloaded |
17 | Not downloaded |
18 | Not downloaded |
19 | Not downloaded |
20 | Not downloaded |
21 | Not downloaded |
22 | Not downloaded |
23 | Not downloaded |
24 | Not downloaded |
------------------------------------------------------
Enter AP number (1 - 24, 0 for all, R for return):
6 At the end of the AP Downloading State Table, do one of the following:
■
press <Enter>.
(Figure 60).
■
■
Type 0to download software to all VCN AP cards and press <Enter>.
The downloading messages and the downloading results table appear
(Figure 60).
Type r and press <Enter> to cancel.
The VCN AP Software Download Menu (Figure 56) reappears.
Download from Www.Somanuals.com. All Manuals Search And Download.
66
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Figure 60 AP Downloading Results
Begin sending version...
Sending version complete
Waiting for acknowledge...
Downloading complete.
Downloading complete. See results in the table:
------------------------------------------------------
| AP | Downloading || AP | Downloading |
| number |
status
|| number |
status
|
------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
|
|
1 | Successful
2 | Successful
3 | Successful
4 | Successful
5 | Failed
6 | Failed
7 | Failed
8 | Failed
9 | Failed
||
||
||
||
||
||
||
||
||
||
||
||
13 | Successful
14 | Failed
15 | Failed
16 | Failed
17 | Failed
|
|
|
|
|
|
|
|
|
|
|
|
18 | Successful
19 | Failed
20 | Successful
21 | Successful
22 | Successful
23 | Successful
24 | Successful
10 | Failed
11 | Failed
12 | Failed
------------------------------------------------------
Press ENTER to continue ...
Check Software Download for the LC Cards:
To check the software download results in the LC cards, type 4and press
<Enter> in the Software Download Menu. The LC Downloading State
Table appears.
Check Software Download for the VCN APs:
To check the software download results of the VCN APs, type 5 and press
<Enter> in the Software Download Menu. The VCN AP Downloading
State appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Software Download
67
Solving Problems in If the LC Downloading Results in Figure 58 show download failed for one
Remote Software or more Line Cards or the AP Downloading Results in Figure 60 show
to solve the problems.
Download Failed for all LCs and all VCN APs
Check the following:
■
Downloading VCN AP software version.
If the version is not 3.5 or later, locally download version 3.5 or the
later version to the VCN AP. Refer to Appendix C, Loading Software
Through Local Access.
■
■
Downloading VCN AP connections to the network.
Check the configuration of your switch and perform the following
step:
Run the ConfApp program on the switch or perform manual
configuration according to Visitor and Community Based Networking
Access Concentrator Service Manual, the section Configuring the
Ethernet Switch for the VCN Access Concentrator.
Perform remote software download again.
Download Failed for One or More Line Cards but not All
Check the following:
■
Software version of the failed LCs.
If the version is not 3.5 or later, locally download the current software.
Refer to the Visitor and Community Based Networking Access
Concentrator Service Manual. Remote software download need not
be performed after this step.
■
■
Check the physical path between the downloading VCN AP and the
VCN AC.
Check the configuration of your switch and perform the following
steps:
Run the ConfApp program on the switch or perform manual
configuration according to Visitor and Community Based Networking
Access Concentrator Service Manual, the section Configuring the
Ethernet Switch for the VCN Access Concentrator.
Perform remote software download again.
Download from Www.Somanuals.com. All Manuals Search And Download.
68
CHAPTER 4: USING THE LOCAL MANAGEMENT ACCESS
Download Failed for One or More VCN APs but not All
Check the following:
■
AP software version of the failed APs.
If the version is not 3.0 or later, locally download the current software
version to the VCN AP. Refer to Appendix C, Loading Software
Through Local Access. Remote software download need not be
performed after this step.
■
Check the physical path between the downloading VCN AP and the
VCN APs.
■
■
Check the VDSL connection between the failed APs and the VCN AC.
Check the configuration of your switch and perform the following
steps:
Run the ConfApp program on the switch or perform manual
configuration according to Chapter 2, Using the Local Management
Access, section Configuring the Ethernet Switch for the VCN Access
Concentrator.
Perform remote software download again.
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
A
This appendix explains how to identify and correct problems, and how to
perform related diagnostic tasks.
If you have problems that are not addressed in this chapter, contact
3Com Technical Support or your service person. Refer to Appendix F for
technical support information.
Power-on Self Test
(POST)
When the VCN Access Point is plugged-in, the VCN AP immediately starts
the power-on self test (POST) sequence as indicated by the power LED
flashing in green. If the VCN AP is not powered, the power LED remains
OFF. Check the power connections and the ac/dc adapter.
The power-on self test verifies that every component of the VCN AP is
fully functional. The power-on self test lasts for 30 seconds at the most,
during which time it is orange. If the power-on self test is successfully
completed, the power LED turns green. If the power-on self test detected
a VCN AP failure, the power LED remains orange. In this case, contact
3Com technical support; refer to Appendix F, Technical Support.
Use the front panel LEDs to determine each port’s status:
Table 7 Determining VCN AP Status During POST
State
Ethernet Line
Power Notes
Off VCN AP is not connected to a
power source or failed.
Orange Test is in progress
Off VCN AP failed
Off
-
-
Power-on
Power-on
-
-
-
-
Download from Www.Somanuals.com. All Manuals Search And Download.
70
APPENDIX A: TROUBLESHOOTING
Using Front Panel
LEDs to Solve
Problems
This section describes the use of the LEDs to solve problems. Figure 61
displays the VCN AP LED indicators.
Figure 61 The VCN AP Unit Front View
ETHERNET
Fax-Modem
Ethernet
LED
Line LED
Power LED
Table 8 describes the LEDs.
Table 8 The VCN AP LEDs
LED
State
Indicates
Ethernet Green
VCN AP connected a PC.
Line
OFF
VCN AP is not connected to the line.
VCN AP connected to the VCN AC.
Green
Flashing Data transmission to or from the VCN AC.
Green
Power
OFF
VCN AP is not powered.
Orange
First 30 seconds after connection to the power
main, power-on-self-test (POST) in progress.
After 30 seconds, POST failed.
The VCN AP is functioning.
Green
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Front Panel LEDs to Solve Problems
71
Use the front panel LEDs to determine the VCN AP status after POST.
Table 9 provides detailed information summarized in Table 10.
Table 9 Determining VCN AP status from the LED Indications after POST
State
Ethernet
Line
Power
Notes
OFF
OFF
OFF
OFF
VCN AP is not
connected to a power
source.
Power-on
ON if user
OFF if the line is During
If the Power LED
remains orange after
30 seconds (POST),
the technician uses
the RS-232 LMI
data cable is not connected. POST, the
connected. If the line is LED is
connected, it is orange. If
steady green for the LED
2 minutes after remains
OFF if user
cable is not
connected.
connector and
POST; After 2
minutes it can
orangeafter terminal emulation to
30 seconds, view the VCN AP
be steady green the VCN AP diagnostic messages
if there is no
traffic, and
is faulty and on his terminal screen.
should be
flashing green if replaced.
there is traffic.
The above states
are normal.
If the LED is not
steady green
during the first 2
minutes after
POST, there is a
communication
problem.
Any other
appearance
after the first 2
minutes
indicates the
presence of a
problem.
Voice Call
Not
Applicable
(NA)
NA
NA
Connection to power
is not needed to make
a voice call.
An Ethernet
connection is not
required.
Download from Www.Somanuals.com. All Manuals Search And Download.
72
APPENDIX A: TROUBLESHOOTING
Table 9 Determining VCN AP status from the LED Indications after POST
State
Fax/Modem Not
Call Applicable
(NA)
Ethernet
Line
Power
Notes
NA
NA
No power is needed to
make a fax/modem
call.
An Ethernet
connection is not
required.
DataTransfer ON
from PC
Flashing in
green
ON
Indicates data is
passing through the
VCN AP.
There is a
valid
Data is passing
between the
connection user PC and the
between network
the VCN AP through the
and the user VCN AP.
PC.
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Front Panel LEDs to Solve Problems
73
Table 9 Determining VCN AP status from the LED Indications after POST
State
Ethernet
Line
Power
Notes
Replace ac/dc adapter
VCN AP
Failure
OFF after
connection: and try again. If the
Indicated
Possible
causes:
problem is eliminated,
the problem was the
adapter. If not, the
problem is in the VCN
AP; replace it and
■
■
faulty
power
adapter
send it to 3Com.
problem
in the
VCN AP
OFF and the
user data
cable is
ON (green) One of the items
below failed:
■
■
■
user data cable
user PC NIC
VCN AP
connected.
Try replacing each of
the first 2 items. If the
problem is not
eliminated, the
problem is in the VCN
AP; replace it and
send it to 3Com.
The Line LED
does not turn
steady green
during 2
minutes after
POST
Possible causes are:
■
■
■
■
no connection
wiring
VCN AC
punch down
block/patch panel
Power the VCN AP
OFF, then ON. If the
VCN AP starts
properly, the problem
is solved. If not,
replace it and send it
to 3Com.
Download from Www.Somanuals.com. All Manuals Search And Download.
74
APPENDIX A: TROUBLESHOOTING
Table 10 Summary of VCN AP LED Indications after POST
Problem
Solution
The power LED
remains OFF after
power connection
Check the power connections and the ac/dc adapter. Plug in
the power cable if necessary.
The power LED
remains orange
longer than 30
seconds.
A hardware fault has been detected in the VCN AP.
Power the VCN AP OFF and then ON. If the problem persists,
contact 3Com.
The Line LED is not
green.
Check the line connection. If the line connections are
appropriate, the VCN AP is not functioning.
Power the VCN AP OFF and then ON. If the problem persists,
contact 3Com.
The Ethernet LED is
OFF.
Check the Ethernet cable. The problem could be in your NIC
or in the VCN AP.
Power the VCN AP OFF and then ON. If the problem persists,
contact 3Com.
Using a PC Terminal
Emulator to Solve
Problems
Refer to Appendix E for setting the parameters of a terminal emulation
program. Then refer to Chapter 4 Using the Local Management Accessfor
connecting the management PC to the VCN AP to operate the
management menus.
Download from Www.Somanuals.com. All Manuals Search And Download.
Using a PC Terminal Emulator to Solve Problems
75
Ethernet Traffic The normal frame counters indicate traffic between the VCN AP and user
Counts PC. Some errored frame counters indicate fatal errors, requiring
replacement of the VCN AP, Ethernet cable or the user’s PC Network
Interface Card (NIC).
The following table depicts normal count indications of the Ethernet
traffic counters and probable causes for abnormal indications.
Table 11 Ethernet Traffic Counters
Abnormal Count
Indicates
Counter
Counts the Frames Normal Count
Tx frame
Sent via the Ethernet Increases as traffic is No data transmitted;
Port.
generated
hardware problem:
■
■
■
VCN AP Tx channel
User Ethernet cable
No VCN AP
connection
Rx frame
Received via the
Ethernet port.
Increases as traffic is No data received;
generated hardware problem:
■
■
■
VCN AP Rx channel
User Ethernet cable
No VCN AP
connection
Rx collision
The VCN AP was
unable to receive
Zero or steady. For VCN AP port hardware
non-zero count,
failure.
due to collisions on reset the counter
the line
and wait a
reasonable period
of time to check for
no significant
increase.
CRC error,
overrun,
Alignment
error, frame
too long,
frame too
short
Containing receive
fatal errors.
Zero
Hardware failure: VCN
AP, Ethernet cable or PC
NIC
HDLC Traffic Counts Normal frame counts indicate traffic between the VCN AP and the VCN
AC. Some errored frame counters indicate fatal errors, requiring
replacement of the VCN AP (failure between the analog front-end section
and the CPU section), or handling of environmental noise over the line.
Download from Www.Somanuals.com. All Manuals Search And Download.
76
APPENDIX A: TROUBLESHOOTING
The following table depicts normal counter indications and probable
causes of abnormal counter indications.
Table 12 HDLC Traffic Count Indicators
Abnormal count
indicates
Counter
Counts the Frames Normal Count
Tx frames
Sent via the
telephone line
High
High
Low
No transmit data
Rx frames
Received via
telephone line
No receive data
Tx discarded
Rx discarded
The VCN AP was
unable to send
VCN AP software
failure
The VCN AP was
unable to receive
Low, unless the
traffic is
VCN AP software
limitation
bi-directional
Overrun, Not
mine, DPLL
error, Abort
sequence, Non
aligned, CRC
error, Frame too
long
Containing Receive
fatal errors
Zero/low
VCN AP hardware
failure if abnormal
count is growing
significantly by the
minute
Summary of The following provides a quick reference to problem identification by
Abnormal Indications using frame counts:
from Traffic Counts
Table 13 Summary of Problems Indicated by Counts of Errored Frames
Problem
Solution
The following Ethernet traffic counters are
growing significantly: CRC error, Overrun,
Replace in this order: the VCN AP,
or the Ethernet cable, or the PC
Alignment error, Frame too long, or Frame too NIC.
short.
The following HDLC traffic counters are
growing significantly: Tx error, Overrun, Not
mine, DPLL error, Abort sequence,
Replace the VCN AP.
Nonaligned, CRC error, Frame too long.
Error Messages There are two types of error messages that appear on the management
terminal screen:
■
Advisory
Download from Www.Somanuals.com. All Manuals Search And Download.
Using a PC Terminal Emulator to Solve Problems
77
The only error message of this type is Wrong entry!It appears when
the user enters the wrong response to a menu. The user solves the
problem by re-entering his response.
When a user disconnects the management terminal from the LMI port
and later reconnects, the LMI menu system stays in the same state and
expects the same user input after reconnect. During reconnect the user
may press the wrong sequence of keys and cause Wrong entry!to be
displayed on the screen. Type 0and press <Enter> a few times until the
desired menu appears.
■
Fatal
Almost all error messages that do appear are fatal. Contact Technical
Support when an error message, except for Wrong entry!, appears. The
most common fatal error messages are listed in Table 14.
Table 14 Fatal Error Messages
Error message
FATAL ERROR: SDRAM test Hardware error during Contact Technical Support.
failed! boot-up
FATAL ERROR: failed FLASH Hardware error during Contact Technical Support.
Significance
User Action
access!
boot-up
Ethernet selftest failed!
Hardware error during Contact Technical Support.
initialization
HDLC selftest failed!
I2C selftest failed!
Hardware error during Contact Technical Support.
initialization
Hardware error during Contact Technical Support.
initialization
DRAM data bus test fail!
Hardware error
Contact Technical Support.
Contact Technical Support.
DRAM address bus test fail! Hardware error
Boot-up and initialization are processes that occur when the VCN AP is
reset. Reset occurs when the user selects Reset boardfrom the menu
system.
Download from Www.Somanuals.com. All Manuals Search And Download.
78
APPENDIX A: TROUBLESHOOTING
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATION
B
Line Data Rate
Range
Up to 10 Mbps, symmetric
up to 4000 ft
Cabling
CAT1 to CAT5
Voice
Dial Tone, Toll Quality, PBX features support
Power requirements
VCN AP Mains
ac/dc adapter
Standards Compliance
Safety
90-260 ac, 47-63 Hz, 6 Watt maximum
3.3 Vdc /1.5 A, 5 Vdc /150 mA, -5 Vdc /50 mA
UL 1950
C-UL, CSA22.#950
EN60950
IEC950
TS-001
EMC
FCC Part 15 Class B
AS/NZS 3548
VCCI Class B
CISPR22 Class B
CAN/CSA-CISPR22 Class B
EN 55022 Class B, Amendment A1, Amendment A2
EN 55024
IEC 61000-4-2 through 61000-4-6, IEC 61000-4-11
Ethernet
IEEE 802.3
Management interface
Environmental
1 RS-232 port
Operating Temperature
Relative humidity
0°- 50°C
95% non-condensing
Download from Www.Somanuals.com. All Manuals Search And Download.
80
APPENDIX B: PRODUCT SPECIFICATION
Download from Www.Somanuals.com. All Manuals Search And Download.
LOADING SOFTWARE THROUGH
LOCAL ACCESS
C
This appendix describes how to load a new software release into the VCN
AP through the LMA port.
Loading software requires using a PC in terminal emulation mode. Refer
to Appendix E Terminal Emulation Settings for a description of terminal
emulation procedures.
To load software into an VCN AP, perform the following steps:
1 Attach your terminal emulating PC to the LMA port on the VCN AP.
2 Press any key to view the VCN AP Main Menu on the terminal screen. If
another menu appears, press 0 (zero) and ENTER repeatedly until the
Main Menu appears.
3 In the Main Menu (Figure 62) type 3, and press ENTER.
Download from Www.Somanuals.com. All Manuals Search And Download.
82
APPENDIX C: LOADING SOFTWARE THROUGH LOCAL ACCESS
Figure 62 VCN AP Main Menu
VCN AP Main Menu
------------------
1. VCN AP Version
2. Debug Menu
3. Management Menu
4. VDSL control
5. Test control
6. Flash actions
7. VCN AP Configuration
8. Software Download Menu
0. Exit
Please enter your choice:
The Management Menu appears:
Figure 63 VCN AP Management Menu
Management Menu
-----------------
1. Ethernet menu
2. HDLC menu
4. Reset all counters
5. Reset board
0. Return to main menu
Please enter your choice:
4 In the Management Menu type 5to reset the VCN AP. The dialog in
Figure 64 appears:
Figure 64 Confirm Reset Board
:
This action will reset the whole board!
Do you want to proceed (Y/[N])? :
Download from Www.Somanuals.com. All Manuals Search And Download.
83
5 Type Yto reset. The screen in Figure 65 appears:
Figure 65 Software Download Option
********************************************************
3Com NCD. (C)
10Base-S Boot loader V2.00
Date: Jun 15 1999, Time: 16:13:31
CPE modem Operation Mode Selector.
Enter:
S - for Serial loading
D - for Debug operation
OR
OR
F - for SW execution from the Flash OR
C - for MAC address programming.
********************************************************
6 Type S; the downloading message appears (Figure 71).
The option of Fin the Software Download Menu (Figure 65), is the
default; if the Software Download Menu displays for 5 seconds,
execution from the flash automatically begins. The option of Dis for
debug purposes only and should only be carried out by system
developers. Option Cis for entering the MAC address. This is normally
performed in the factory.
Figure 66 Software Downloading Message
******************************
Load procedure via Serial Line.
******************************
Waiting for downloading...
Download from Www.Somanuals.com. All Manuals Search And Download.
86
APPENDIX C: LOADING SOFTWARE THROUGH LOCAL ACCESS
While the file is downloading, the status window in Figure 70 appears:
Figure 70 Send File Status Window
The VCN AP software is downloaded to the flash memory in the VCN AP,
and the messages in Figure 71 and Figure 72 appear:
Download from Www.Somanuals.com. All Manuals Search And Download.
87
Figure 71 Software Downloading Message
Start saving to the FLASH!
Sector passed number-12
Sector passed number-13
Sector passed number-14
Sector passed number-15
Sector passed number-16
Sector passed number-17
Sector passed number-18
Sector passed number-19
Sector passed number-20
Sector passed number-21
Sector passed number-22
Sector passed number-23
Flash erased OK!
Storage2 has been erased!
Application buffer address - 99e8
Last write address - 2940004
Last write data
Last written data - f
Data counter - 1
- f
Indicator has been written!
Application buffer address - 160000
Last write address - 2940008
Last write data
- 0
Last written data - 0
Data counter
- 393211
SW image has been saved!
Application buffer address - 66d0
Last write address - 2940000
Last write data
Last written data - 55aa
Data counter - 1
- 55aa
Signature has been written!
The SW version has been saved to the FLASH!
SW image is being executed!!!
*****************************
Start executing main!
Watchdog initialized OK !
Download from Www.Somanuals.com. All Manuals Search And Download.
88
APPENDIX C: LOADING SOFTWARE THROUGH LOCAL ACCESS
Figure 72 Self-Test Messages
HDLC selftest passed!
Ethernet selftest passed!
I2C selftest passed!
VDSL selftest passed!
MNG task created!
MNG task started!
LED task created!
LED task started!
DWN task created!
DWN task started!
LMA task created
LMA task started
The Login prompt appears.
After the software download, the unit starts to execute the software from
the flash memory.
If, instead of the messages in Figure 71, one of the following messages
appear, the software load failed:
■
Flash Error
■
SW image validation failed
Action:
Try to load the software again. If the problem persists, replace
the VCN AP.
Download from Www.Somanuals.com. All Manuals Search And Download.
PIN ASSIGNMENTS FOR LMA
CABLE
D
This appendix describes the pin assignments for the LMA cable, see
Figure 73. The cable is used in an RS-232 connection.
Figure 73 Local Management Access Cable
Connector for Local
Management
Terminal
The connector for the local management (LM) terminal emulating
computer is displayed in Figure 74. The connector consists of a DB 9-pin
female connector. Table 15 describes the pin assignments.
Figure 74 DB 9-Pin Female Connector
5
4
3
2
1
9
8
7
6
Table 15 LM Terminal Connector Pin Assignment
Pin No. Assignment
1
2
3
4
5
Not used
Tx
Rx
Not used
Ground (GND)
Download from Www.Somanuals.com. All Manuals Search And Download.
90
APPENDIX D: PIN ASSIGNMENTS FOR LMA CABLE
Table 15 LM Terminal Connector Pin Assignment
Pin No. Assignment
6
7
8
9
Not used
Not used
Not used
Not used
Connector for the The connector for the LMA port of the VCN AP is described below. The
LMA Port of the connector consists of a MiniDIN 4-pin male connector, see Figure 75.
VCN AP Table 16 describes the pin assignments.
Figure 75 MiniDIN 4-Pin Connector Pin Numbering
4
2
3
1
Table 16 LMA Port Connector Pin Assignment
Pin No. Assignment
1
2
3
4
Tx
Rx
GND
GND
Download from Www.Somanuals.com. All Manuals Search And Download.
Local Management Cable Wiring
91
Local Management
Cable Wiring
This section describes the connection of the pins in the LM terminal
connector to the pins in the VCN AP LMA port connector within the
cable. Figure 76 depicts the connections in the cable. Table 17 lists the
pin connections for the wires in the cable. The Tx and Rx directions relate
to the VCN AP, not the LM terminal.
Figure 76 LM Cable Wiring
3
1
4
2
5
4
3
2
1
9
8
7
6
Table 17 LM Cable Connections
MiniDIN
Pin No.
DB-9
Pin No. Assignment
1
2
3
4
2
3
5
5
Tx
Rx
GND
GND
Download from Www.Somanuals.com. All Manuals Search And Download.
92
APPENDIX D: PIN ASSIGNMENTS FOR LMA CABLE
Download from Www.Somanuals.com. All Manuals Search And Download.
TERMINAL EMULATION SETTINGS
E
This appendix describes the terminal emulation settings for Procomm
Plus. Procomm Plus is presented here as an example of a terminal
emulation program; you can use another program with similar settings.
Defining the
Terminal Emulation
Settings
To define the terminal emulation settings:
below:
■
Double-click the Procomm Plus shortcut if it appears on the PC
Desktop.
or
■
Select Start > Programs > Procomm Plus.
The Procomm Plus Terminal screen in Figure 77 appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
94
APPENDIX E: TERMINAL EMULATION SETTINGS
Figure 77 Procomm Plus Terminal Screen
Configuration
Bar
Terminal type
Data Code
PC Communication
Port
Bits per
Second
ASCII
parameters
Establishing
Terminal Settings
Terminal settings can be established in one of two ways:
■
Using the Configuration Bar
Using the Menu Bar
■
Using the To establish terminal settings using the configuration bar:
Configuration Bar
1 From the Configuration Bar, establish the settings listed in Table 18.
Table 18 Procomm Plus Settings
No From Left
Function
Settings
1
Type of Terminal
ANSI BBS
Download from Www.Somanuals.com. All Manuals Search And Download.
Establishing Terminal Settings
95
Table 18 Procomm Plus Settings (continued)
No From Left
Function
Settings
2
3
Data Code
ASCII
PC serial communication COMx
port
4
5
Bits per second
115200
8-N-1:
ASCII parameters
8 bits
No parity
1 stop bit
2 If necessary, click the appropriate button to display a list of all possible
settings and select the required settings.
Using the Menu Bar To establish terminal settings using the menu bar:
1 Select Options > System Options > Modem Connection. The Setup
window as shown in Figure 78 opens.
Figure 78 Procomm Setup Window
2 Select System Tab.
Download from Www.Somanuals.com. All Manuals Search And Download.
96
APPENDIX E: TERMINAL EMULATION SETTINGS
3 From the Current Modem/Connection window, select direct
connect-ComX, where X represents the number of your com port.
4 Click Modem/Connection Properties. The Modem/Connection Properties
window as shown in Figure 79 opens.
Figure 79 Connection Properties Window
5 From the Baud rate window, select 115200.
6 Set the following parameters:
■
■
■
■
Parity: None.
Data bits: 8.
Stop bits: 1.
Flow control
■
Use hardware flow control is the default.
Use software flow control
■
Set Use software flow control if your computer works better with
software flow control.
7 Click OK.
8 Click OK.
Your terminal is now ready for local management functions and for
downloading software.
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SUPPORT
F
3Com provides easy access to technical support information through a
variety of services. This appendix describes these services.
3Com Corporation World Wide Web site.
Online Technical
Services
through the following online systems:
■
■
■
■
■
World Wide Web Site
3Com Knowledgebase Web Services
3Com FTP Site
3Com Bulletin Board Service
3Com Facts Automated Fax Service
World Wide Web Site To access the latest networking information on the 3Com Corporation
World Wide Web site, enter this URL into your Internet browser:
http://www.3com.com/
This service provides access to online support information such as technical
documentation and software, as well as support options that range from
technical education to maintenance and professional services.
3Com This interactive tool contains technical product information compiled by
Knowledgebase Web 3Com expert technical engineers around the globe. Located on the World
Services Wide Web at http://knowledgebase.3com.com, this service gives all
3Com customers and partners complementary, round-the-clock access to
technical information on most 3Com products.
Download from Www.Somanuals.com. All Manuals Search And Download.
98
APPENDIX F: TECHNICAL SUPPORT
3Com FTP Site Download drivers, patches, software, and MIBs across the Internet from the
3Com public FTP site. This service is available 24 hours a day, 7 days a week.
To connect to the 3Com FTP site, enter the following information into
your FTP client:
■
■
■
Hostname: ftp.3com.com
Username: anonymous
Password: <your Internet e-mail address>
You do not need a user name and password with Web browser software
such as Netscape Navigator and Internet Explorer.
3Com Bulletin Board The 3Com BBS contains patches, software, and drivers for 3Com products.
Service This service is available through analog modem or digital modem (ISDN)
24 hours a day, 7 days a week.
Access by Analog Modem
To reach the service by modem, set your modem to 8 data bits, no parity,
and 1 stop bit. Call the telephone number nearest you:
Country
Australia
Brazil
Data Rate
Telephone Number
61 2 9955 2073
55 11 5181 9666
33 1 6986 6954
4989 62732 188
852 2537 5601
39 2 27300680
81 3 5977 7977
52 5 520 7835
Up to 14,400 bps
Up to 28,800 bps
Up to 14,400 bps
Up to 28,800 bps
Up to 14,400 bps
Up to 14,400 bps
Up to 14,400 bps
Up to 28,800 bps
Up to 14,400 bps
Up to 14,400 bps
Up to 28,800 bps
Up to 53,333 bps
France
Germany
Hong Kong
Italy
Japan
Mexico
P.R. of China
Taiwan, R.O.C.
U.K.
86 10 684 92351
886 2 377 5840
44 1442 438278
1 847 262 6000
U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
Support from Your Network Supplier
99
Access by Digital Modem
ISDN users can dial in to the 3Com BBS using a digital modem for fast
access up to 64 Kbps. To access the 3Com BBS using ISDN, call the
following number:
1 847 262 6000
3Com Facts The 3Com Facts automated fax service provides technical articles,
Automated Fax diagrams, and troubleshooting instructions on 3Com products 24 hours a
Service day, 7 days a week.
Call 3Com Facts using your Touch-Tone telephone:
1 408 727 7021
Support from Your
Network Supplier
If you require additional assistance, contact your network supplier. Many
suppliers are authorized 3Com service partners who are qualified to
provide a variety of services, including network planning, installation,
hardware maintenance, application training, and support services.
When you contact your network supplier for assistance, have the
following information ready:
■
■
■
■
Product model name, part number, and serial number
A list of system hardware and software, including revision levels
Diagnostic error messages
Details about recent configuration changes, if applicable
If you are unable to contact your network supplier, see the following
section on how to contact 3Com.
Support from 3Com If you are unable to obtain assistance from the 3Com online technical
resources or from your network supplier, 3Com offers technical telephone
support services. To find out more about your support options, call the
3Com technical telephone support phone number at the location nearest
you.
Download from Www.Somanuals.com. All Manuals Search And Download.
100
APPENDIX F: TECHNICAL SUPPORT
When you contact 3Com for assistance, have the following information
ready:
■
■
■
■
Product model name, part number, and serial number
A list of system hardware and software, including revision levels
Diagnostic error messages
Details about recent configuration changes, if applicable
Here is a list of worldwide technical telephone support numbers:
Country
Telephone Number
Country
Telephone Number
Asia, Pacific Rim
Australia
Hong Kong
India
Indonesia
Japan
Malaysia
New Zealand
Pakistan
Philippines
1 800 678 515
800 933 486
P.R. of China
10800 61 00137 or
021 6350 1590
800 6161 463
+61 2 9937 5085
001 800 61 009
0031 61 6439
1800 801 777
0800 446 398
+61 2 9937 5085
1235 61 266 2602
Singapore
S. Korea
From anywhere in S. Korea: 00798 611 2230
From Seoul:
Taiwan, R.O.C.
Thailand
(0)2 3455 6455
0080 611 261
001 800 611 2000
Europe
From anywhere in Europe, call: +31 (0)30 6029900 phone
+31 (0)30 6029999 fax
Europe, South Africa, and Middle East
From the following countries, you may use the toll-free numbers:
Austria
Belgium
Denmark
Finland
France
Germany
Hungary
Ireland
Israel
0800 297468
0800 71429
800 17309
0800 113153
0800 917959
0800 1821502
00800 12813
1800 553117
1800 9453794
1678 79489
Netherlands
Norway
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
0800 0227788
800 11376
00800 3111206
0800 831416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
Italy
Latin America
Argentina
Brazil
Chile
Colombia
AT&T +800 666 5065
0800 13 3266
1230 020 0645
98012 2127
Mexico
Peru
Puerto Rico
Venezuela
01 800 CARE (01 800 2273)
AT&T +800 666 5065
800 666 5065
AT&T +800 666 5065
North America
1 800 NET 3Com
(1 800 638 3266)
Enterprise Customers:
1 800 876-3266
Download from Www.Somanuals.com. All Manuals Search And Download.
Returning Products for Repair 101
Returning Products
for Repair
Before you send a product directly to 3Com for repair, you must first
obtain an authorization number. Products sent to 3Com without
authorization numbers will be returned to the sender unopened, at the
sender’s expense.
To obtain an authorization number, call or fax:
Country
Telephone Number
+ 65 543 6500
Fax Number
Asia, Pacific Rim
+ 65 543 6348
+ 31 30 6029999
Europe, South Africa, and
Middle East
+ 31 30 6029900
Latin America
1 408 326 2927
1 408 326 3355
From the following countries, you may call the toll-free numbers; select option 2 and
then option 2:
Austria
0800 297468
0800 71429
800 17309
Belgium
Denmark
Finland
France
Germany
Hungary
Ireland
0800 113153
0800 917959
0800 1821502
00800 12813
1800553117
1800 9453794
1678 79489
0800 0227788
800 11376
00800 3111206
0800 831416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
Israel
Italy
Netherlands
Norway
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
U.S.A. and Canada
1 800 NET 3Com
(1 800 638 3266)
1 408 326 7120
(not toll-free)
Enterprise Customers:
1 800 876 3266
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
flash memory 86
3Com Knowledgebase Web Services 97
3Com URL 97
G
3ComFacts 99
guide is intended for 3
A
H
Abnormal Indications from Traffic Counts 76
hardware version 42
HDLC 48
account number 36
applications 12
status 49
traffic counters 48
B
bulletin board service 98
I
intranet 12
ISP 34, 36
C
Calls 35
conventions
L
LAN
Line connector 16
D
LMA
load 81
Loading software 81
loading software 83
local management cable 89
Local Management port 57
LMA port 38
local management terminal 89
local software download 81
local software load fail 88
log-in procedure 36
E
electric connection 33
Ethernet over VDSL 58
Ethernet port 11, 36
Ethernet status 44
Ethernet traffic count 76
Ethernet traffic counts 43
F
fax service (3ComFacts) 99
faxes, sending 36
M
Main Menu 42
Download from Www.Somanuals.com. All Manuals Search And Download.
104
INDEX
Management Menu 42
MIBs 98
MiniDIN connector 90
monitoring 37
T
technical support
3Com Knowledgebase Web Services 97
3Com URL 97
bulletin board service 98
fax service 99
mounting
multiple tenant units 11
network suppliers 99
product repair 101
telephone connection 33
terminal emulation 37
troubleshooting 37
N
O
U
Operation instructions 35
URL 97
V
P
VCN AP
paper template 23
password 36
POTS 9, 10
VCN Services Switch 10 13
VCNAP connections 33
VCNAP LMA port connector 90
VDSL 54
power connector 16
PSTN 34
Q
QAM 54
VDSL Control Menu 53
Version 42
Visitor and Community Based Networking
system 11
voice call 35
R
Remote software download
Requirements 58
reset all counters 51
W
World Wide Web (WWW) 97
returning products for repair 101
RJ-45 cable 36
rubber pads 32
S
Software Download VLAN ID 61
software version 42
solving problem 69
SuperStack II Switch 3300 13
Download from Www.Somanuals.com. All Manuals Search And Download.
3Com Corporation LIMITED WARRANTY
LIMITED WARRANTY
This warranty applies to customers located in the United States, Australia, Canada (except Quebec), Ireland,
New Zealand, U.K., and other English language countries, and countries for which a translation into the local
language is not provided
Visitor and Community Network
HARDWARE:
3Com warrants to the end user (“Customer”) that this hardware product will be free from defects in
workmanship and materials, under normal use and service, for the following length of time from the date of
purchase from 3Com or its authorized reseller:
3Com’s sole obligation under this express warranty shall be, at 3Com’s option and expense, to repair the
defective product or part, deliver to Customer an equivalent product or part to replace the defective item, or
if neither of the two foregoing options is reasonably available, 3Com may, in its sole discretion, refund to
Customer the purchase price paid for the defective product. All products that are replaced will become the
property of 3Com. Replacement products may be new or reconditioned. 3Com warrants any replaced or
repaired product or part for ninety (90) days from shipment, or the remainder of the initial warranty period,
whichever is longer.
SOFTWARE
3Com warrants to Customer that each software program licensed from it will perform in substantial
conformance to its program specifications, for a period of ninety (90) days from the date of purchase from
3Com or its authorized reseller. 3Com warrants the media containing software against failure during the
warranty period. No updates are provided. 3Com’s sole obligation under this express warranty shall be, at
3Com’s option and expense, to refund the purchase price paid by Customer for any defective software
product, or to replace any defective media with software which substantially conforms to applicable 3Com
published specifications. Customer assumes responsibility for the selection of the appropriate applications
program and associated reference materials. 3Com makes no warranty or representation that its software
products will meet Customer’s requirements or work in combination with any hardware or applications
software products provided by third parties, that the operation of the software products will be
uninterrupted or error free, or that all defects in the software products will be corrected. For any third-party
products listed in the 3Com software product documentation or specifications as being compatible, 3Com
will make reasonable efforts to provide compatibility, except where the noncompatibility is caused by a
“bug” or defect in the third party's product or from use of the software product not in accordance with
3Com’s published specifications or User Guide.
THIS 3COM PRODUCT MAY INCLUDE OR BE BUNDLED WITH THIRD-PARTY SOFTWARE, THE USE OF WHICH
IS GOVERNED BY A SEPARATE END-USER LICENSE AGREEMENT. THIS 3COM WARRANTY DOES NOT APPLY
TO SUCH THIRD-PARTY SOFTWARE. FOR THE APPLICABLE WARRANTY, PLEASE REFER TO THE END-USER
LICENSE AGREEMENT GOVERNING THE USE OF SUCH SOFTWARE.
YEAR 2000 WARRANTY
In addition to the Hardware Warranty and Software Warranty stated above, 3Com warrants that each
product sold or licensed to Customer on and after January 1, 1998, that is date sensitive will continue
performing properly with regard to such date data on and after January 1, 2000, provided that all other
products used by Customer in connection or combination with the 3Com product, including hardware,
software, and firmware, accurately exchange date data with the 3Com product, with the exception of those
products identified at 3Com’s Web site, http://www.3com.com/products/yr2000.html, as not meeting this
standard. If it appears that any product that is stated to meet this standard does not perform properly with
regard to such date data on and after January 1, 2000, and Customer notifies 3Com before the later of April
1, 2000, or ninety (90) days after purchase of the product from 3Com or its authorized reseller, 3Com shall,
at its option and expense, provide a software update which would effect the proper performance of such
product, repair such product, deliver to Customer an equivalent product to replace such product, or if none
of the foregoing is feasible, refund to Customer the purchase price paid for such product.
Any software update or replaced or repaired product will carry a Year 2000 Warranty for ninety (90) days
after purchase or until April 1, 2000, whichever is later.
Download from Www.Somanuals.com. All Manuals Search And Download.
OBTAINING WARRANTY
SERVICE
Customer must contact a 3Com Corporate Service Center or an Authorized 3Com Service Center within the
applicable warranty period to obtain warranty service authorization. Dated proof of purchase from 3Com or
its authorized reseller may be required. Products returned to 3Com’s Corporate Service Center must be
preauthorized by 3Com with a Return Material Authorization (RMA) number or User Service Order (USO)
number marked on the outside of the package, and sent prepaid and packaged appropriately for safe
shipment, and it is recommended that they be insured or sent by a method that provides for tracking of the
package. Responsibility for loss or damage does not transfer to 3Com until the returned item is received by
3Com. The repaired or replaced item will be shipped to Customer, at 3Com’s expense, not later than thirty
(30) days after 3Com receives the defective product.
3Com shall not be responsible for any software, firmware, information, or memory data of Customer
contained in, stored on, or integrated with any products returned to 3Com for repair, whether under
warranty or not.
Dead- or Defective-on-Arrival. In the event a product completely fails to function or exhibits a defect in
materials or workmanship within the first forty-eight (48) hours of installation but no later than thirty (30)
days after the date of purchase, and this is verified by 3Com, it will be considered dead- or
defective-on-arrival (DOA) and a replacement shall be provided by advance replacement. The replacement
product will normally be shipped not later than three (3) business days after 3Com’s verification of the DOA
product, but may be delayed due to export or import procedures. The shipment of advance replacement
products is subject to local legal requirements and may not be available in all locations. When an advance
replacement is provided and Customer fails to return the original product to 3Com within fifteen (15) days
after shipment of the replacement, 3Com will charge Customer for the replacement product, at list price.
WARRANTIES EXCLUSIVE
IF A 3COM PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY FOR
BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE
PAID, AT 3COM’S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND
REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS,
EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING
WARRANTIES, TERMS, OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,
SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, AND NONINFRINGEMENT, ALL OF
WHICH ARE EXPRESSLY DISCLAIMED. 3COM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO
ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, OR
USE OF ITS PRODUCTS.
3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT
THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY
CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING,
UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR, OR MODIFY THE PRODUCT, OR ANY OTHER CAUSE BEYOND
THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, POWER CUTS OR OUTAGES,
OTHER HAZARDS, OR ACTS OF GOD.
LIMITATION OF LIABILITY
TO THE FULL EXTENT ALLOWED BY LAW, 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY
LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL,
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE or
profits, LOSS OF BUSINESS, loss of information or data, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN
CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR
INTERRUPTION OF ITS PRODUCTS, EVEN IF 3COM OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE
PURCHASE PRICE paid, AT 3COM’S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE
AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
DISCLAIMER
Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the
limitation of incidental or consequential damages for certain products supplied to consumers, or the
limitation of liability for personal injury, so the above limitations and exclusions may be limited in their
application to you. When the implied warranties are not allowed to be excluded in their entirety, they will be
limited to the duration of the applicable written warranty. This warranty gives you specific legal rights which
may vary depending on local law.
Download from Www.Somanuals.com. All Manuals Search And Download.
GOVERNING LAW
This Limited Warranty shall be governed by the laws of the State of California, U.S.A. excluding its conflicts of
laws principles and excluding the United Nations Convention on Contracts for the International Sale of
Goods.
3Com Corporation
5400 Bayfront Plaza
P.O. Box 58145
Santa Clara, CA 95052-8145
(408) 326-5000
June 7, 1999
Ninety (90) days
INCLUDED SERVICES:
Telephone Support, with coverage for basic troubleshooting only, will be
provided for ninety (90) days from the date of purchase, on a commercially
reasonable efforts basis. Telephone support is available from 3Com only if
Customer purchased this product directly from 3Com, or if Customer’s
reseller is unable to provide telephone support. Please refer to the Technical
Support appendix in the User Guide for telephone numbers.
Software Updates, consisting of software and firmware upgrades, soft-
ware update notifications, and the latest code download through the 3Com
Software Library, will be provided for ninety (90) days from the date of pur-
chase. To qualify for this software updates service, Customer must register
on the 3Com Web site and provide date of product purchase, product num-
ber, and serial number.
Download from Www.Somanuals.com. All Manuals Search And Download.
EMC STATEMENTS
FCC CLASS B VERIFICATION
STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
■
■
■
■
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CSA STATEMENT
VCCI STATEMENT
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
This is a Class B product based on the standard of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic
environment, it may cause radio interference. Install and use the equipment according to the instruction
manual.
EMC DIRECTIVE COMPLIANCE
STATEMENT
This equipment was tested and found to conform to the Council Directive 89/336/EEC for electromagnetic
compatibility. Conformity with this Directive is based upon compliance with the following harmonized
standards:
■
■
EN 55022
Limits and Methods of Measurement of Radio Interference
EN 50082-1 Electromagnetic Compatibility Generic Immunity Standard:
Residential, Commercial, and Light Industry
This equipment conforms to the Class B limits of EN 55022.
AUSTRALIAN COMPLIANCE
This product conforms to the EMC Frameworks and meets the Class B limits of AS3548.
SAFETY STATEMENT
LOW VOLTAGE DIRECTIVE
COMPLIANCE
This equipment was tested and found to conform to the Council Directive 72/23/EEC for safety of electrical
equipment. Conformity with this Directive is based upon compliance with the following harmonized
standard:
EN 60950
Safety of Information Technology Equipment