Intel Centrino Pro User Manual

Intel® vPro™ and Intel®  
Centrino® Pro  
Guide  
Intel® Centrino® with vPro™ Technology  
Intel® Core™2 Processor with vPro™ Technology  
Processor  
Technology Quick  
Start Guide  
Based on Intel® Active Management Technology and LANDesk®  
Management Suite 8.8  
Version 1.8  
October 2008  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Preface  
This document provides the high level steps required to deploy desktop and notebook PCs with Intel®  
vPro™ technology. It does not provide step-by-step procedures for completing those high level steps,  
but instead provides links to more detailed information where such step-by-step procedures may be  
found.  
Intended Audience  
This Quick Start Guide is intended for Information Technology (IT) professionals, system integrators,  
and other technical specialists with experience deploying computer systems and networking  
technologies in an Information Technology environment. It is not intended for general audiences.  
What This Document Contains  
Section  
Description  
Process Overview  
Provides a brief overview of the overall deployment process; lists high  
level steps, including decisions to be made, which are explained in  
more detail in subsequent sections.  
Deciding Which Provisioning Mode To  
Use  
Provides the necessary information to make the decision as to which  
provisioning mode will best suit your deployment needs based on the  
size and complexity of your IT environment.  
Deploying Intel vPro Using SMB (Basic)  
Mode Provisioning  
Provides the overall steps to deploy Intel vPro based systems into your  
IT environment using SMB (also known as Basic) mode provisioning.  
Deploying Intel vPro Using Enterprise  
(Standard and Advanced) Mode  
Provisioning  
Provides the overall steps to deploy Intel vPro based systems into your  
IT environment using Enterprise (composed of both Standard and  
Advanced) mode provisioning.  
Appendix A: Troubleshooting  
Provides information on correcting problems that may arise during  
deployment.  
Appendix B: Glossary  
Provides a list of terms used in this document and their definitions.  
3
       
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Process Overview  
Intel® Active Management Technology1 (Intel® AMT) provides significant flexibility in order to meet the  
needs of various customer environments. This flexibility requires that customers make a number of  
decisions when planning and implementing their deployment of Intel AMT-enabled systems.  
The overall deployment process is shown below:  
Install the LANDesk Management System (LDMS) agent on each client system. Since you will  
ultimately be utilizing the LANDesk Management Suite to manage your vPro clients the LANDesk  
Client Agent should be installed prior to provisioning Intel vPro. You can either push the client  
agent from the LANDesk Management Console or in the case of the One-Touch provisioning you  
can pull the client agent from the LANDesk Management Console. By having the client agent  
installed prior to provisioning the Intel vPro client you are not subject to your DNS resolving the  
host name and therefore provisioning should be fairly quick and easy.  
Decide which provisioning mode to use (SMB or Enterprise). This decision determines which of  
the subsequent sections of this guide you will use to accomplish the remaining steps (below).  
See Section 1 for information on deciding which provisioning mode to use.  
Install or validate infrastructure components (DNS, DHCP, SQL Server, etc.).  
Ensure required Windows* drivers (for SOL and IDE-R) are installed on vPro clients.  
Configure your management console to manage Intel vPro clients.  
Configure Intel vPro components (Intel ME and Intel AMT) in Intel® Management Engine BIOS  
Extension (Intel® MEBx) on Intel vPro clients.  
Discover Intel vPro clients in your management console.  
Test Intel vPro client management functionality in your management console.  
Perform post configuration steps (IT support process changes, maintenance procedures, etc.).  
For Additional Information: Most sections will have a reference to additional information. Below is the  
URL where you can locate the documents referenced throughout the paper.  
Note: If you decide to use Enterprise mode provisioning, the process described above can vary  
significantly depending on whether or not you plan to use Remote Configuration, which uses Public Key  
Infrastructure (PKI) to authenticate communication between the provisioning server and the Intel vPro  
clients, and automates some of the steps above. See the flow chart in the next section below for a  
visual representation of the overall provisioning process, and the various “paths” through it depending  
on which provisioning mode and method you choose.  
1. Intel® Active Management Technology (Intel® AMT) is a hardware-based technology that facilitates remote out-of-band  
management of computers by use of a small secondary processor located on the motherboard.  
This out of band (OOB) controller has embedded firmware that runs on the Intel® Management Engine (Intel® ME), a separate  
small ARC architecture processor built into either the North Bridge or NIC of the motherboard. The Intel AMT firmware is stored in  
the same SPI flash memory component used to store the BIOS and is generally updated along with the BIOS.  
4
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Section 1: Deciding Which Provisioning Mode to Use  
Before starting the deployment, you must decide which provisioning mode to use: SMB or Enterprise.  
Note: SMB mode, which stands for “Small-Medium Business,” is also known as “Basic” mode, and  
Enterprise mode can be divided into “Standard” and “Advanced” modes, based on whether you require  
Transport Layer Security (TLS) certificate-based encryption for you management traffic.  
Several factors should be considered in deciding which provisioning mode to use, such as security  
requirements, size of organization, and existing IT infrastructure.  
The primary difference between SMB and Enterprise modes is the ability to encrypt management traffic.  
In the Advanced Enterprise mode, all management traffic may be encrypted with Transport Layer  
Security (TLS). In SMB mode and the Standard Enterprise mode the traffic is not encrypted.  
The other major difference in provisioning modes is how the client system receives its configuration  
information. In Enterprise mode, you can use manual, one-touch, or remote configuration options, or  
have your OEM pre-provision the client systems before shipment. In SMB mode, you must manually  
provision each client system.  
The following questions can help you decide which mode to use.  
Question  
Yes  
No  
Do your security needs require that  
all traffic from a management  
console to the Intel vPro machine be  
encrypted?  
You must choose Enterprise  
Advanced mode.  
You may choose either SMB or  
Enterprise  
Is your IT infrastructure set up to  
support either Static IP or Windows  
Workgroups?  
You should choose SMB (Basic)  
mode; manual management of the  
client host list is required.  
You may choose either SMB or  
Enterprise  
Is your organization small enough to You may choose either SMB or  
provision each system manually? Enterprise  
You should choose Enterprise  
Where do I go from here?  
Selected provisioning mode:  
Go to:  
SMB  
page 6  
Enterprise  
5
     
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Section 2 – Deploying Intel® vPro Using SMB (Basic)  
Mode Provisioning  
Process Flowchart  
The following picture shows the overall process flow for provisioning Intel vPro client systems in SMB  
mode. The steps are described in further detail in this section.  
6
     
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 1: Configure Existing IT Infrastructure  
Step 1a: Choose DHCP or Static IP Addressing for Client Systems.  
If your IT environment requires the use of static IP addresses, be aware that the Intel AMT client must  
then have two IP addresses: one for the host OS and one for the Intel Management Engine (Intel ME).  
Use of static IP addresses also requires that the host OS and Intel ME on the client system have  
separate host (computer) names.  
DHCP is recommended if it is supported in your IT environment. This allows the Intel AMT client to  
share a single IP address and hostname with the client OS. If static IP addressing is required for some  
applications, use reserved addresses for those clients that require a static IP address. This allows the  
application that requires a static IP address to meet its requirements, but allows Intel AMT to use one IP  
address and hostname instead of two.  
If using DHCP, configure DHCP to support Option 81 so that the client provides its fully qualified domain  
name (FQDN) to the DHCP server, as well as instructions on how the DHCP server should process DNS  
updates for the client. Option 15 should also be enabled in the DHCP Scope Options to allow the DNS to  
resolve host queries after IP address changes.  
Step 1b: Set Firewall/Router Ports  
Set Firewall/Router Ports 16992 and 16994 to “open” for Intel AMT management traffic.  
Step 2: Verify Intel vPro Client Windows Drivers  
The following Intel AMT drivers, which are digitally signed by Intel and compatible with Microsoft  
Windows* operating systems (including Windows 2000, Windows XP, and Windows Vista*), are required  
on the Intel AMT client platform. Obtain these drivers from your client system manufacturer’s driver and  
download support pages (most client drivers and Intel MEBx updates are contained on the same support  
web page by the OEM).  
Intel® Management Engine Interface (Intel MEI) driver -- Provides a secure local  
communications interface between the host operating system and the Intel ME via the Intel MEI.  
Serial-over-LAN (SoL) driver -- Enables a COM port for VT100 or ANSI remote sessions prior to  
graphic interface when the operating system loads. You can view and send commands to a  
remote client prior to the operating system loading, including entering into the BIOS, viewing  
POST, etc.  
Local Management Service (LMS) driver –Provides an interface enabling local management  
software agents to communicate with the Intel Management Engine using the same high-level  
protocols as those used for remote management (e.g. XML, SOAP). When first loaded, the driver  
will cause a pop-up to occur to confirm that Intel AMT is running. The pop-up can be disabled. As  
the Intel AMT firmware is updated, this driver is most likely to require a coordinated update as  
new features are enabled. The driver also checks for consistency of the Intel AMT hostname and  
the operating system host name.  
7
     
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
It is recommended that the LANDesk client agent also be installed, although it is not required.  
Discovery of the Intel vPro machine will differ depending on whether the client agent is installed. See  
information.  
Step 3: Ensure Management Console Has the Correct Intel AMT  
Support  
The Intel vPro features included in LANDesk System Manager (LSM) are now built into LANDesk  
Management Suite (LDMS) 8.8. This is a change from LDMS 8.7 where both LDMS and LMS were  
required for full Intel vPro functionality. LDMS 8.8 supports all Intel AMT features including System  
Defense and Agent Presence. LDMS 8.8 also supports both the wired and wireless functionality of  
systems based on Intel® Centrino® 2 with vPro™ technology.  
Step 3a: Set Password:  
1. In the LANDesk Configure Services tool, enter a strong password on the Intel vPro  
Configuration tab.  
2. In the Current Intel vPro Credentials area, enter the current name and password for the  
Intel MEBx. This name and password will be used to enter the Intel MEBx after the original  
provisioning process has finished.  
The Intel Management Engine BIOS Extension (Intel MEBx) is an option ROM module extension  
to the system BIOS. It.is provided to the OEM by Intel. The Intel MEBx allows you to  
configure settings that control the operation of the Management Engine which runs on the Intel  
AMT client. For more information on Intel MEBx, see the Intel Management Engine BIOS  
Extension User’s Guide.  
Note: Use the same password in step 4c below when you change the Intel MEBx password on  
the Intel vPro client.  
3. Leave the bottom half of the screen, Provision with new Intel vPro Credentials, blank at  
this time.  
8
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 3b: Select TLS or non-TLS mode.  
Under the Discovery & Provisioning portion of the dialog box you’ll find two options:  
Provision in TLS mode for secure communication  
Provision in non-TLS mode  
Since you have made the choice to use SMB mode, select “Provision in non-TLS mode,” then click  
Apply.  
Step 4: Configure Intel vPro Client BIOS  
Step 4a: Confirm You Have the Latest BIOS and Firmware Version  
Visit your Original Equipment Manufacturer (OEM) website to determine if you have the latest versions  
of BIOS and firmware. If an update is needed, follow the instructions provided by the OEM to  
implement the update.  
Examples of OEM BIOS updates include:  
HP:  
Dell:  
Step 4b: Enter the Intel MEBx  
There are two methods to enter the Intel MEBx.  
Ctrl-P: Start the Intel AMT enabled system. After the BIOS settings screen has passed, another  
screen is displayed prompting you to enter Ctrl-P. Type Ctrl-P to enter the Intel MEBx.  
BIOS: Some local OEMs have chosen to have the Intel MEBx be a portion of their regular BIOS  
menu system. In this case enter the keystrokes to launch their BIOS settings screen (usually F2  
or Del).  
Step 4c: Change the Intel MEBx Password  
Upon entering the Intel MEBx for the first time, you will be required to enter the default password,  
which is “admin.” When you enter the Intel MEBx for the first time, you will be prompted to change the  
password. The Intel MEBx password must meet “strong” password criteria which include:  
Be between 8- and 32-characters long  
9
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Contain both upper and lower case Latin characters  
Have at least one numeric character  
Have at least one ASCII non-alphanumeric character (!, @, #, $, %, ^, &, *)  
Step 4d: Select an IP Addressing Scheme  
SMB mode supports both Static IP and Dynamic Host Protocol Configuration (DHCP). DHCP is the most  
commonly used scheme today and provides the easiest integration with Intel AMT. If DHCP is your  
choice, simply ensure that the DHCP value is set properly in the MEBx (“DHCP Disabled? No”).  
If you choose static IP addressing, the Intel AMT client must have two IP addresses, one for the host OS  
and one for the Intel Management Engine (Intel ME). Static IP addressing also requires a separate host  
(computer) name for the host OS and the Intel ME. To select static IP addressing, select “DHCP  
Disabled? Yes.” You’ll then be prompted to enter the IP information including IP address, subnet  
mask, default gateway, and primary and secondary DNS server.  
A host name must be entered into the Intel MEBx whether you choose static IP or DHCP within SMB  
mode. It is not necessary to enter the Domain name into the Intel MEBx for SMB mode.  
Step 4e: Set Additional Intel MEBx Parameters  
There are a number of parameters that you can change in the Intel MEBx. All fields have a default  
setting that may vary slightly depending on the system’s manufacturer. However, you’ll need to pay  
particular attention to the following settings for SMB mode.  
Setting  
Description or value  
Intel AMT Configuration Mode  
Configuration Server Options  
Intel AMT Hostname  
Set to SMB  
Not needed because these apply only to enterprise mode  
In SMB mode this is required. If you use DHCP, this must match  
computer name in the host OS. If you use static IP addressing, this  
name must be unique from the computer name in the host OS.  
Intel AMT Domain Name  
DHCP Enabled  
This will match the Domain Name in the Host OS  
DHCP is recommended, but in SMB, both DHCP and Static IP addressing  
are supported  
Refer to documentation provided by your hardware manufacturer to determine which settings you need  
to change.  
For an example of an OEM configuration document:  
10  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 5: Discover Intel vPro Clients Through the Management Console  
Discovery of the Intel vPro devices varies depending on whether the latest LANDesk client agent is  
loaded.  
Discovery Without the LANDesk Agent Installed on the Client:  
1. In LANDesk, navigate to the Unmanaged Device Discovery (UDD) tab. The bottom half of the  
UUD tab displays the undiscovered devices,  
2. On the UUD tab, click the Intel AMT category to display the discovered Intel vPro machines.  
Allow a few minutes for the Intel AMT client to display as the LANDesk Core Database must  
complete a refresh before the Intel AMT client appears. If the client still does not display after  
a few minutes, click on the refresh icon in the UDD tool bar (second icon from left).  
3. Move the Intel vPro machines to your management database by right-clicking one of the  
devices and selecting Move to Inventory Database. Repeat for each Intel vPro machine.  
4. Click the All Devices list to see the Intel vPro machines. You may need to click Refresh if the  
All Devices list was already displayed when you moved the Intel vPro machines.  
5. Right click an Intel vPro machine to see all the Intel AMT selections available.  
Discovery With the LANDesk Agent Installed on the Client:  
No explicit action is required to discover Intel vPro client systems if the LANDesk Agent is installed on  
them. If the LANDesk Agent is installed on the client system, then that client system will already be  
listed in the All Devices list in LANDesk.  
However, when you activate the Intel Management Engine (Intel ME) on the client using the process  
described in Steps 3 and 4 on the preceding pages, you will then see the Intel vPro selections available  
for that client when you right click on it in the All Devices list.  
Step 6: Test Intel vPro Client Functionality  
After the device has been discovered and added to the management database, it is a good idea to test  
the functionality of the Intel vPro machine. Perform the following steps to test the Intel AMT client  
functionality.  
Step 6a: Test Intel AMT Client Functionality From LANDesk  
1. In the All Devices list, right-click an Intel AMT device to display the menu of Intel AMT Options.  
2. At a minimum, look at the following Intel AMT Options to test that the Intel AMT configuration  
has been successfully completed:  
o Intel AMT Summary  
11  
     
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
o Remote Boot Manager – Power On/Off  
o Remote Boot Manager using Console Redirection (Serial over LAN /SOL) and IDE  
Redirection  
For further information on testing these features, refer to the following whitepaper:  
Integrating Intel® vPro™ Technology with LANDesk® Management Products  
Step 6b: Test Intel AMT Client Functionality Using Intel AMT Web Console  
1. On the management console system, login as an administrator with user rights.  
2. Open a web browser and enter the IP address and assigned port number (16992) in the  
browser address bar (example, http://192.168.0.1:16992).  
The following web browsers are supported:  
o Internet Explorer* 6.0 SP1  
o Netscape* 7.2 for Windows and Linux  
o Mozilla Firefox* 1.0 for Windows and Linux  
o Mozilla 1.7 for Windows and Linux  
3. Once the Intel AMT Configuration Web Page is displayed, login using ”admin” as the username  
and the Intel MEBx “strong” password you created in Step 4c on page 12. You can then view  
the following client management information:  
o System Status  
o Hardware Information  
o Event Log  
o Remote Control  
o Network Settings  
o User Accounts  
12  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 7: Post Configuration  
Once you’ve deployed and configured your Intel vPro client machines, there are still some additional  
actions you should consider.  
Adding New Devices:  
As new Intel vPro clients are added to the network you will need to perform the deployment process  
described above to activate Intel AMT on the new devices, discover the new devices, and then add them  
to your management database. This procedure should be added to your standard maintenance  
procedures.  
Updating Procedures to Include Intel AMT Features:  
Work with your management console to determine how best to utilize the new capabilities available to  
you through your Intel vPro devices. Further, it is a good idea to update your procedures to utilize Intel  
vPro features, such as those procedures your help desk staff follow when helping users. For example,  
you will want to update the process to re-image a PC that has blue screened at a remote site using the  
new Intel AMT features (i.e., SOL and IDE – Redirection) now available in your management console.  
Using Agent Presence (AP):  
Agent Presence (AP) monitors for the existence of agents. The LANDesk client agents must be installed  
on the client PC in order to use AP. AP is automatically configured when the LANDesk client agents are  
installed. However, you can perform additional configuration in the Configure | Intel vPro Options |  
Agent Presence | Configuration page of the LDMS console.  
Agent Presence is either enabled for all managed Intel AMT 2.x machines or disabled for all machines. It  
cannot be enabled or disabled for specific machines. AP enabling is controlled by the Enable Agent  
Presence Monitoring check-box in the configuration page mentioned above.  
By default, AP monitors the following two processes on the client machine:  
Agent  
Reason for AP Monitoring  
LANDesk Management Agent (RESIDENTAGENT.EXE)  
The LANDesk Management Agent is monitored because  
most of the Client\Server communication between  
LANDesk agents and the LANDesk Core is done through  
this agent.  
LANDesk Monitoring Service (COLLECTOR.EXE)  
The LANDesk Monitoring Service is monitored because  
it is the heart of the LANDesk monitoring system.  
While these agents are running you can monitor any other service on the client machine using the LSM  
service monitoring tool. These agents and their descriptions are defined in AGENTPRESENCE.XML which  
is sent down to the Intel AMT non-volatile memory (NVM) storage area on the client Intel AMT machine  
and subsequently read by the LANDesk agent to determine what it should monitor.  
13  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Once AP starts on the client (default startup time is 6 minutes after the client is powered on), if the  
COLLECTOR.EXE process is killed or the LANDesk Management Agent service is stopped, an AP alert is  
generated. AP start and stop alerts are displayed in the LSM log, not the Intel AMT Event Log.  
Note: If the COLLECTOR.EXE process is killed, restart it by running RESTARTMON.EXE, which is located  
in the LDCLIENT folder on the client system.  
LANDesk Management Suite 8.8 has the ability to have Agent Presence trigger a System Defense policy  
to isolate the client system from the network. This can be done by creating an Intel AMT Agent  
Presence alert in the LSM console (under the Core Ruleset) with the action of “Place in the Intel AMT  
Remediation Queue.” With this alert rule in place, if a monitored process on the client is stopped, an  
Agent Presence alert is generated by Intel AMT and sent to the LANDesk core server. The core server  
will then issue a System Defense policy to the client that will stop all network traffic except for LANDesk  
management traffic, Intel AMT traffic, DNS traffic, and DHCP traffic, thus isolating the client system  
from the network except for system management functions.  
Using LANDesk* Out-of-Band Monitor (AMTMON) Features:  
LANDesk 8.8 has the ability to disable the network on the client at the OS level. This is not done  
through the System Defense feature, but rather through LANDesk agents and communication via the  
Intel AMT non-volatile memory (NVM) area. When you select to disable or enable the network on that  
client, a flag is set in NVM on the client, which is monitored by the service LANDesk* Out-of-Band  
Monitor (AMTMON.EXE). The AMTMON service disables or enables the network on the client based on  
the value of the flag in NVM. AMTMON can also run a vulnerability scan on the client at the next  
restart, if that flag is set. A message dialog is displayed on the client system whenever these three  
operations are performed.  
Note: Do not ping the Intel AMT client to test if the network is disabled. Intel AMT will still respond to  
pings.  
System Defense (SD):  
System Defense (SD) does not require any agents to be installed on the Intel AMT client machine.  
System Defense policies may be configured on a per-machine basis.  
There are four pre-defined SD policies:  
An FTP access policy which will trigger SD if an FTP access is made either to or from the Intel  
AMT client machine.  
A UDP flood policy which will trigger SD if Intel AMT sees at least 20,000 UDP packets per second  
and will monitor for a Denial-of-service attack.  
An SYN flood policy which will trigger SD if Intel AMT sees at least 20,000 IP packets per second  
and will monitor for a Denial-of-service attack.  
14  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
A Kill All NICs policy which will stop all network traffic except for LANDesk management, Intel  
AMT, DNS, and DHCP traffic, thus isolating the client system from the network except for system  
management functions.  
Note: In LANDesk 8.8 there is no GUI to create or modify System Defense filters or policies. Currently  
all modifications have to be made to the XML pages used for System Defense.  
Once SD triggers an alert, the alert is displayed in the LSM log. LANDesk and Intel AMT limit network  
access by replacing the current client policy with the Kill All NICs policy when SD is triggered. The client  
machine is also placed in the Remediation queue, which can be found in Configure | System Defense  
| Remediation. Once the machine is remediated, the Kill All NICs policy is removed and the previous  
policy is re-applied. The administrator must manually perform the actual remediation of removing the  
virus or spyware, or fixing whatever caused the SD to be triggered.  
15  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Section 3 – Deploying Intel vPro Using Enterprise  
(Standard and Advanced) Mode Provisioning  
Process Flowchart  
The following picture shows the overall process flow for provisioning Intel vPro client systems in  
Enterprise (Standard and Advanced) mode. The steps are described in further detail in this section.  
16  
     
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Intel vPro Enterprise Setup and Configuration Flow  
Prior to executing the steps for configuring the Intel vPro components (Intel AMT and Intel ME) in  
Enterprise mode (either Standard or Advanced), it is first important to understand the overall flow of  
the Enterprise mode configuration process (recall that the main difference between Standard and  
Advanced is that if you provision your clients in Advanced mode, all management traffic between the  
management console and the managed clients will be encrypted using cert-based encryption).  
In Enterprise mode, an Intel vPro machine receives its configuration settings over the network, once it  
has been prepared with some initial setup information. The following diagram shows the modes or  
states that an Intel vPro device passes through before it becomes operational.  
Intel vPro Configuration States:  
1. Factory State  
– AMT disabled  
– No network configuration  
– No security credentials  
SETUP  
(Pre-Provisioning)  
2. Setup State  
– AMT enabled  
– Basic network configured  
– Admin credentials loaded  
CONFIGURATION  
(Provisioning)  
3. Configured State  
– AMT fully configured (e.g power policies)  
– Security credentials fully loaded  
– Ready for remote management  
Factory State: An Intel vPro machine comes from the OEM in Factory State. In this state Intel AMT is  
un-configured and not available for use by management applications. When an operator enters  
information via the Intel Management Engine BIOS extension (Intel MEBx) manually or with the aid of a  
USB storage device, the Intel vPro machine makes the transition into the setup state. See Step 3 –  
Configure AMT Client BIOS for instructions on how to prepare an Intel vPro machine to receive its  
configuration settings from a Setup and Configuration Application (SCA) which is inherent in LDMS.  
Setup State: When an Intel vPro machine enters Setup State it waits for delivery of its configuration  
settings from the LDMS core server. After it enters setup mode, the Intel vPro machine periodically  
sends messages to the LDMS core server. When the LDMS core server receives messages from the Intel  
vPro machine, it responds by delivering the configuration settings and placing the device in Operational  
State.  
Operational State: The Intel vPro machine enters Operational State once its configuration settings  
have been supplied and committed. At this point the Intel vPro machine is ready to interact with  
management applications.  
17  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 1: Configure Existing IT Infrastructure  
In order for an Intel vPro machine to be manageable, it must become known to the management  
console. The process by which this occurs is called “provisioning”. Enterprise setup (pre-provisioning)  
requires a series of steps that are performed on both the Intel vPro clients and the LANDesk core server  
in order to prepare the client for provisioning over the network by the LANDesk core server (which acts  
as the provisioning server for the Intel vPro clients).  
Intel vPro Integration Points with IT Infrastructure Components  
The following diagram shows the interaction with the different network elements. Each will be  
discussed briefly in order to understand the integration requirement.  
Manages  
Manages  
Core Server  
Configuration Server  
Intel® vPro™  
CA Server  
Management  
Console  
Clients  
SQL DB  
Updates  
DHCP  
DNS  
DHCP Server: When an Intel vPro machine enters setup state, the default IP addressing scheme is  
DHCP (that is, use DHCP to obtain an IP address). The Intel® Management Engine (Intel® ME) also  
uses the DHCP server to help dynamically update the DNS server with its network address information.  
The DHCP server must support Option 81 to register network address information into the DNS server  
on behalf of the Intel ME. Option 15 should also be enabled in the DHCP Scope Options to allow the  
DNS to resolve host queries after IP address changes.  
DNS Server: The DNS Server is used by network devices such as Management Consoles to locate  
address information for Intel vPro clients in order to contact them and manage them. The Intel vPro  
clients may also use the DNS server during the provisioning configuration phase to locate the provision  
server and request their configuration information, as explained below.  
Once configured to the setup state, Intel AMT makes a DNS request for the name "ProvisionServer"  
(unless you choose to configure the client’s BIOS manually). If the requested name cannot be resolved  
by the DNS server, then a second request is made for "ProvisionServer.DomainName." Intel AMT  
expects to either find the IP address of the provision server in this way, or by having it set explicitly in  
the Intel MEBx configuration process (Step 4: Configure Intel vPro Client Authentication Settings, page  
21). The Intel Management Engine BIOS Extension (Intel MEBx) is an option ROM module extension to  
18  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
the system BIOS.. It.is provided to the OEM by Intel. The Intel MEBx allows you to configure settings  
that control the operation of the Management Engine which runs on the Intel AMT client. For more  
information on Intel MEBx, see the Intel Management Engine BIOS Extension User’s Guide.  
Step 1a: Manually register the “provision server” entry into the DNS server.  
Manually resister the “provision server” entry into the DNS server.  
Step 1b: Set Firewall/Router Ports Open for Management Traffic  
Intel AMT requires certain ports to be “open” in order to allow management traffic through them. The  
Intel AMT ports are 16992 (non-TLS), 16993 (TLS), 16994 (non-TLS redirection), 16995 (TLS  
redirection) – these are IANA-assigned ports which Intel purchased. They cannot be changed. Port  
9971 is used in Enterprise mode to listen for “Hello” packets. This port is configurable in the LDMS  
console.  
To change the port number on the LANDesk core server, do the following:  
1. Go to the following registry key: SOFTWARE\LANDesk\Management Suite and create a key  
named AMTDiscovery.  
2. Create a DWORD with a name of Port and enter the value you would like to assign as the new  
listening port for the discovery of the Intel AMT Hello packets. You will then need to restart  
the LANDesk® Agentless Discovery Service or reboot the server.  
NOTE: Please refer to your LANDesk documentation or contact LANDesk Professional Services for  
details on performing LANDesk operations that affect the computer’s registry.  
Step 1c: Database Server Integration:  
Intel vPro machines will have information about them (inventory) stored in a repository used by the  
management console. With LANDesk management products, Microsoft SQL and Oracle database  
integration is available. Please refer to your LANDesk documentation on how to successfully integrate  
into the database of choice.  
19  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 2: Verify Intel vPro Client Windows Drivers  
The following Intel AMT drivers, which are digitally signed by Intel and compatible with Microsoft  
Windows* operating systems (including Windows 2000, Windows XP, and Windows Vista*), are required  
on the Intel vPro client platform. Obtain these drivers from your client system manufacturer’s driver  
and download support pages (most client drivers and Intel MEBx updates are contained on the same  
support web page by the OEM).  
Intel Management Engine Interface (Intel MEI) driver -- Provides a secure local  
communications interface between the host operating system and the Intel ME via the Intel MEI.  
Serial-over-LAN (SoL) driver -- Enables a COM port for VT100 or ANSI remote sessions prior  
to graphic interface when the operating system loads. You can view and send commands to a  
remote client prior to the operating system loading, including entering into the BIOS, viewing  
POST, etc.  
Local Management Service (LMS) driver –Provides an interface enabling local management  
software agents to communicate with the Intel Management Engine using the same high-level  
protocols as those used for remote management (e.g. XML, SOAP). When first loaded, the driver  
will cause a pop-up to occur to confirm that Intel AMT is running. The pop-up can be disabled. As  
the Intel AMT firmware is updated, this driver is most likely to require a coordinated update as  
new features are enabled. The driver also checks for consistency of the Intel AMT hostname and  
the operating system host name.  
It is recommended that the LANDesk client agent also be installed, although it is not required.  
Discovery of the Intel vPro machine will differ depending on whether the client agent is installed. See  
information.  
Step 3: Set Intel vPro Password and TLS mode in Management  
Console  
The Intel vPro features included in LANDesk System Manager (LSM) are now built into LANDesk  
Management Suite (LDMS) 8.8. This is a change from LDMS 8.7 where both LDMS and LMS were  
required for full Intel vPro functionality. LDMS 8.8 supports all Intel vPro features including System  
Defense and Agent Presence. LDMS 8.8 also supports both the wired and wireless functionality of  
systems based on Intel® Centrino® 2 with vPro™ technology.  
Two pieces of information are required for Intel vPro in LANDesk: a password to access the Intel MEBx,  
where Intel vPro configuration information is set; and the management network traffic security setting,  
either TLS (secured) or non-TLS (unsecured).  
To ensure Intel vPro support in your management console, do the following:  
20  
     
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 3a: Set Intel MEBx Password  
In the LANDesk Configuration Services tool, click the Intel vPro Configuration tab and enter a  
strong password in the Current Intel vPro Credentials (top) portion of the screen. This is the  
password you will use in the future if you need to access the Intel MEBx on any individual client system  
after the initial provisioning process is complete. See the Intel MEBx User Guide for information on  
accessing and using the Intel MEBx on an Intel vPro machine.  
Leave the bottom half of the screen, Provision with new Intel vPro Credentials, blank.  
Step 3b: Select TLS (Advanced mode) or non-TLS (Standard mode)  
In Advanced mode, Transport Layer Security (TLS) is used to provide privacy and data integrity  
between communicating applications. It allows for Client/Server applications to communicate in a way  
to prevent eavesdropping, tampering, or message forgery. With LDMS, TLS is only available in  
Enterprise Advanced mode provisioning with an Intel vPro machine. The LANDesk core server is used  
to issue the certificates to the proper trusted devices within the network.  
Under the Discovery & Provisioning portion of the dialog box you’ll find two options related to  
encryption:  
Provision in TLS mode for secure communication  
Provision in non-TLS mode  
If you are provisioning in Standard mode, select non-TLS mode. For Advanced mode, select TLS mode  
for secure communication. After making this selection, click Apply.  
Step 4: Configure Intel vPro Client Authentication Settings  
In Enterprise mode, configuring the authentication settings on the Intel vPro clients can be performed in  
either of the following three ways:  
Remote Configuration (Intel AMT 3.0 or higher) – Step 4A below  
OEM pre-configuration – Step 4B below  
One-touch configuration (using a USB thumb drive or manual entry) – Step 4C below  
Step 4A: Remote Configuration (Intel AMT 3.0 or higher) – Factory State to Configured  
State  
Remote Configuration uses matching certificate hashes on the Intel vPro clients and the provisioning  
server to authenticate interaction between the clients and the server. Once the client and server  
authenticate each other (i.e., the certificate hashes match), the provisioning server automatically  
begins provisioning the client.  
With Remote Configuration, you have two choices:  
21  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Use your own root certificate, if you already have one  
Use one of the certificate hashes provided with Intel vPro (i.e., already on the client systems)  
Using your own root certificate: If you already have a root certificate on your LANDesk core server  
(the provisioning server), then you need to do one of the following:  
instruct your Intel vPro client manufacturer (OEM) to place a matching certificate hash on each  
Intel vPro client during manufacture  
manually enter the matching certificate hash using the Intel MEBx on each Intel vPro client  
before deployment  
If you instruct your OEM to load the certificate hashes onto your Intel vPro clients, the clients will  
already have a certificate hash that matches the existing root certificate on your provisioning server  
when they arrive. All you need to do is connect them to the network and power them on and they’ll  
automatically provision themselves (assuming you’ve completed Steps 1-3 above). Then they will be in  
a Configured state.  
Using one of the certificates provided with Intel vPro: If you want to use one of the certificates  
provided with Intel vPro, you will need to purchase a matching root certificate, and load it onto your  
LANDesk core server (the provisioning server). Once a matching root certificate is present on the  
provisioning server, the Intel vPro clients will automatically authenticate themselves with the  
provisioning server at power on, and will then automatically be provisioned by the provisioning server.  
The certificates are purchased from one of the approved Certificate Authority (CA) vendors, such as  
VeriSign, Comodo, Go Daddy, and Starfield. Check with your OEM to see which of these CA vendors  
they support. The certificates are placed in C:\Program  
Files\LANDesk\ManagementSuite\amtprov\certStore.  
1. Create a new folder named cert_1.  
2. Copy the three files that were received from the CA vendor (trusted_cert.pem, corecacert.pem,  
corecakey.pem) into the cert_1 directory. You can create up to eight cert folders to hold eight  
different certs from different CAs.  
3. Some CA vendors may name the certificates differently. To be consistent, renamed the files to:  
o trusted_cert.pem (root cert)  
o corecacert.pem (the cert user buys from the CA)  
o corecakey.pem (the private key the administrator generated when they bought the cert).  
o Trusted_cert_intermediate.pem (The certificate that CA’s use to issue the cert you buy.  
This is issued by the root cert from each CA.)  
When your Intel vPro clients arrive, they will already have a certificate hash that matches the new root  
certificate you just installed on your provisioning server. All you need to do is connect them to the  
network and power them on and they’ll automatically provision themselves (assuming you’ve completed  
Steps 1-3 above). Then they will be in a Configured state.  
22  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Note: You can also test Remote Configuration using a LANDesk generated certificate. The appropriate  
server certificates are already in place. However, the client hash needs to be placed into the Intel ME  
BIOS on the Intel AMT 3.0 client. The client hash is automatically generated and stored at the  
beginning of the AMTDiscService.log file. It will look something like this:  
Fri, 30 Nov 2007 11:30:37 InitInstance()  
Fri, 30 Nov 2007 11:30:37 LANDesk(R) Intel AMT Provisioning Service  
Fri, 30 Nov 2007 11:30:45 sha1 hash: (32A1-F117-AB25-0E1B-482B-7EFE-C0BE-92A7-B090-  
D416)  
Fri, 30 Nov 2007 11:30:45 md5 hash: (D29A-E72B-1029-846C-CE50-4C52-82EC-8F24)  
Fri, 30 Nov 2007 11:31:01 Hash added to DB  
Fri, 30 Nov 2007 11:31:01 Server listens for incoming connections.  
The administrator will need to place the sha1 hash in the ME BIOS on the client.  
For further detailed information on obtaining and configuring certificates see file Installing VeriSign  
You can set several Intel ME and Intel AMT parameters in the LANDesk Management Suite (LDSM), just  
as you would manually in the Intel MEBx directly on the individual client. Intel vPro parameters set in  
the management console are applied to all Intel vPro machines being provisioned.  
Step 4B: OEM Pre-configuration – Factory State to Configured State  
Most OEMs are willing to provide the service of changing the Intel vPro client from factory state to setup  
state by entering the password and client authentication information into the Intel MEBx on each client  
system for you. This often requires an additional fee to the OEM. This method is most useful when an  
Intel vPro client machines are to be delivered directly to the end user from the manufacturer.  
The authentication information (security keys) can be provided to the OEM for loading into the client  
system’s BIOS (via the Intel MEBx), or the OEM could provide you with a list of keys they generated.  
The keys must match between the Intel vPro machines and the management console. The  
management consoles have an option to import and export keys to facilitate this transaction.  
If you ordered your Intel vPro client systems pre-configured with Intel MEBx password and client  
authentication information already loaded by the OEM, then they are already in a Setup state. When  
you connect the client systems to the network and power them on they will automatically authenticate  
themselves with the provisioning server and provisioning will occur (assuming you performed Steps 1-3  
above). Then they will be in a Configured state, ready to be discovered and managed by the  
23  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
management console.  
Step 4C: One-Touch Configuration of Intel vPro Client - Factory State to Setup State  
The Intel vPro clients need authentication information configured on them so that they can authenticate  
themselves to the provisioning server; otherwise the server won’t provision them. This authentication  
information is made up of a Provisioning ID (PID) and a Provisioning Pass-phrase (PPS). Together they  
are referred to as a PID-PPS pair. The server maintains a list of valid PID-PPS pairs, which is matched  
against any incoming PID-PPS pair from a client requesting provisioning. If the client’s PID-PPS  
matches one of the entries in the server’s list, that client is provisioned.  
Note. Do not confuse the TLS security keys that are part of management console interaction with the  
Intel vPro machine and the TLS-PSK keys that are used during setup and configuration. These are  
separate keys. Once the TLS-PSK keys are used during the setup and configuration stage, they are not  
used again unless an Intel vPro machine is re-provisioned. Whereas, the other TLS keys are used for all  
communications from the management console to the Intel vPro machine.  
Step 4C-1: Confirm Latest BIOS Version: It is important that you use the latest BIOS and firmware  
version from the Original Equipment Manufacturer (OEM). Please visit their website to determine the  
latest versions. If an update is needed, follow the instructions provided by the OEM to implement the  
update.  
Examples of OEM BIOS updates  
HP:  
Dell:  
Step 4C-2: Create PID-PPS security keys in LANDesk. Before you can configure the PID-PPS  
information on the Intel vPro clients, you need to generate that information in the LANDesk  
management console.  
1. Open the LDMS console.  
2. Open the “Configure” > “Intel vPro options” > “”ID Generation” option. An option to generate  
Intel AMT IDs is displayed.  
3. Generate the IDs. These IDs contain the PID-PPS pairs that you will then load onto your Intel  
vPro client machines.  
24  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
4. The console will display the values for manual entry into the Intel vPro machine, or there is an  
option to export/import (at the bottom of the dialogue box) the security keys to a USB thumb  
drive (filename setup.bin) for one-touch configuration.  
If you want to use a USB thumb drive to easily transfer the Intel MEBx password and PID-PPS  
security key information to the Intel vPro clients, continue to Step 4C-3, Configure Intel  
vPro Clients Using a USB Thumb Drive. To manually configure the clients, go to Step 4C-  
3a, Manually Configuring the Intel vPro Clients.  
Step 4C-3: Configure Intel vPro Clients Using a USB Thumb Drive: In this method, the new  
password and the PID/PPS keys are exported from the management console onto a USB thumb drive.  
1. In LANDesk, select the option to export the PID-PPS security keys to a setup.bin file, then copy  
the setup.bin file to a USB thumb drive.  
2. Once you have exported the setup.bin file to a USB thumb drive, insert the USB drive into each  
Intel vPro client system during boot up and the information is automatically transferred to the  
Intel ME.  
3. Once the authentication information is transferred, restart the system and let it boot to  
Windows. The Intel vPro client will automatically authenticate itself with the provisioning  
server and provisioning will occur.  
4. Repeat for each Intel vPro client system.  
Note: You can only use the USB key to transfer the PID/PPS information to the Intel MEBx one time  
per client system. A bit is set on the client once the transfer has been made and the client will not  
allow an additional transfer to occur unless the bit is reset. To reset this bit, you would need to clear  
the client Intel Management Engine by performing a Full Un-Provision in the Intel MEBx (reset to factory  
defaults).  
USB Thumb Drive Notes: You should use a USB 2.0 thumb drive and 2 GB or less. Format the USB  
drive in FAT 16 through any Windows client. This must be in FAT 16, not FAT 32. The file (setup.bin)  
that is created by the export function noted above MUST be the first file on the drive, to function  
properly. Once this file is on the drive, other files can then be added as needed.  
You may need to try several USB drives to find one that works, and you may need to try both the front  
and back USB ports on the client system. Refer to the USB Provisioning Matrix for a list of tested  
Once you have configured your clients using the USB thumb drive, skip to Step 5: Discover Intel vPro  
Clients through the Management Console, on page 24.  
25  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 4C-3a: Manual Configuration of the Intel vPro Clients (alternative to USB drive  
method): Use this method to manually enter the password and PID-PPS credentials for each Intel vPro  
client machine.  
A minimal amount of information is required to change the Intel vPro client from Factory Mode to Setup  
Mode. The information required includes:  
Change Intel MEBx password (change from factory default). The default password is “admin.”  
The new ME password must meet “strong” password criteria which include:  
Be between 8 and 32 characters long  
Contain both upper and lower case Latin characters  
Have at least one numeric character  
Have at least one ASCII non-alphanumeric character (!, @, #, $, %, ^, &, *)  
Provisioning ID (PID) and Provisioning Pass-Phrase (PPS). These are used to perform the  
necessary steps of authenticating a new client and initiating the provisioning process. This uses  
Transport Layer Security (TLS) Pre-shared Key (PSK) for authentication.  
To manually update the Intel vPro clients with new Intel MEBx passwords and valid PID-PPS security  
keys, do the following on each client system:  
1. Start the client system, then press Ctrl-P during startup to enter the Intel MEBx.  
2. Change the Intel MEBx password to a “strong” password (use the same password for each  
client system).  
3. Select Intel AMT Configuration, then Setup and Configuration, then TLS-PSK, then Set  
PID and PPS.  
4. Enter one of the PID-PPS combinations from the list of PID-PPS pairs you generated in  
LANDesk (Step 4C-2 above).  
5. Exit the Intel MEBx and reboot the client system to the Windows OS.  
6. Repeat for each Intel vPro client.  
Note: Once the client boots to Windows, it will automatically authenticate itself with the provisioning  
server and provisioning will occur.  
See the Intel Management Engine BIOS Extension (Intel MEBx) User’s Guide for detailed information  
about configuring the Intel ME and Intel AMT using the Intel MEBx.  
26  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 5: Discover Intel vPro Clients through the Management Console  
Discovery of the Intel vPro devices varies depending on whether the latest LANDesk client agent is  
loaded.  
Discovery Without the LANDesk Agent Installed on the Client:  
1. In LANDesk, navigate to the Unmanaged Device Discovery (UDD) tab. The bottom half of the  
UUD tab displays the undiscovered devices,  
2. On the UUD tab, click the Intel AMT category to display the discovered Intel vPro machines.  
Allow a few minutes for the Intel AMT client to display as the LANDesk Core Database must  
complete a refresh before the Intel AMT client appears. If the client still does not display after  
a few minutes, click on the refresh icon in the UDD tool bar (second icon from left).  
3. Move the Intel vPro machines to your management database by right-clicking one of the  
devices and selecting Move to Inventory Database. Repeat for each Intel vPro machine.  
4. Click the All Devices list to see the Intel vPro machines. You may need to click Refresh if the  
All Devices list was already displayed when you moved the Intel vPro machines.  
5. Right click an Intel vPro machine to see all the Intel AMT selections available.  
Discovery With the LANDesk Agent Installed on the Client:  
No explicit action is required to discover Intel vPro client systems if the LANDesk Agent is installed on  
them. If the LANDesk Agent is installed on the client system, then that client system will already be  
listed in the All Devices list in LANDesk.  
However, when you activate the Intel Management Engine (Intel ME) on the client using the process  
described in Steps 3 and 4 on the preceding pages, you will then see the Intel vPro selections available  
for that client when you right click on it in the All Devices list.  
27  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Step 6: Test Intel vPro Client Functionality  
After the device has been discovered and added to the management database, it is a good idea to test  
the functionality of the Intel vPro machine. Perform the following steps to test the Intel AMT client  
functionality.  
Step 6a: Test Intel vPro Client Functionality From LANDesk  
1. In the All Devices list, right-click an Intel vPro device to display the menu of Intel AMT Options.  
2. At a minimum, look at the following Intel vPro Options to test that the Intel AMT configuration  
has been successfully completed:  
o Intel vPro Summary  
o Remote Boot Manager – Power On/Off  
o Remote Boot Manager using Console Redirection (Serial over LAN /SOL) and IDE  
Redirection  
For further information on testing these features, refer to the following whitepaper:  
Integrating Intel® vPro™ Technology with LANDesk® Management Products  
Step 6b: Test Intel AMT Client Functionality Using Intel AMT Web Console  
1. On the management console system, login as an administrator with user rights.  
2. Open a web browser and enter the IP address and assigned port number (16992 for non-TLS,  
The following web browsers are supported:  
o Internet Explorer* 6.0 SP1 or later  
o Netscape* 7.2 for Windows and Linux  
o Mozilla Firefox* 1.0 for Windows and Linux  
o Mozilla 1.7 for Windows and Linux  
3. Once the Intel AMT Configuration Web Page is displayed, login using the Intel MEBx username  
and password. You can then view the following client management information:  
o System Status  
o Hardware Information  
o Event Log  
o Remote Control  
28  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
o Network Settings  
o User Accounts  
Step 7: Post Configuration  
Once you’ve deployed and configured your Intel vPro client machines, there are still some additional  
actions you should consider.  
Adding New Devices:  
As new Intel vPro clients are added to the network you will need to perform the deployment process  
described above to activate Intel AMT on the new devices, discover the new devices, and then add them  
to your management database. This procedure should be added to your standard maintenance  
procedures.  
Updating Procedures to Include Intel AMT Features:  
Work with your management console to determine how best to utilize the new capabilities available to  
you through your Intel vPro devices. Further, it is a good idea to update your procedures to utilize Intel  
vPro features, such as those procedures your help desk staff follow when helping users. For example,  
you will want to update the process to re-image a PC that has blue screened at a remote site using the  
new Intel AMT features now available in your management console.  
Using Agent Presence (AP):  
Agent Presence (AP) monitors for the existence of agents. The LANDesk client agents must be installed  
on the client PC in order to use AP. AP is automatically configured when the LANDesk client agents are  
installed. However, you can perform additional configuration in the Configure | Intel Vpro Options |  
Agent Presence | Configuration page of the LDMS console.  
Agent Presence is either enabled for all managed Intel AMT 2.x machines or disabled for all machines. It  
cannot be enabled or disabled for specific machines. AP enabling is controlled by the Enable Agent  
Presence Monitoring check-box in the configuration page mentioned above.  
By default, AP monitors the following two processes on the client machine:  
Agent  
Reason for AP Monitoring  
LANDesk Management Agent (RESIDENTAGENT.EXE)  
The LANDesk Management Agent is monitored because  
most of the Client\Server communication between  
LANDesk agents and the LANDesk Core is done through  
this agent.  
LANDesk Monitoring Service (COLLECTOR.EXE)  
The LANDesk Monitoring Service is monitored because  
it is the heart of the LANDesk monitoring system.  
29  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
While these agents are running you can monitor any other service on the client machine using the LSM  
service monitoring tool. These agents and their descriptions are defined in AGENTPRESENCE.XML which  
is sent down to the Intel AMT non-volatile memory (NVM) storage area on the client Intel AMT machine  
and subsequently read by the LANDesk agent to determine what it should monitor.  
Once AP starts on the client (default startup time is 6 minutes after the client is powered on), if the  
COLLECTOR.EXE process is killed or the LANDesk Management Agent service is stopped, an AP alert is  
generated. AP start and stop alerts are displayed in the LSM log, not the Intel AMT Event Log.  
Note: If the COLLECTOR.EXE process is killed, restart it by running RESTARTMON.EXE, which is located  
in the LDCLIENT folder on the client system.  
LANDesk Management Suite 8.8 has the ability to have Agent Presence trigger a System Defense policy  
to isolate the client system from the network. This can be done by creating an Intel AMT Agent  
Presence alert in the LSM console (under the Core Ruleset) with the action of “Place in the Intel AMT  
Remediation Queue.” With this alert rule in place, if a monitored process on the client is stopped, an  
Agent Presence alert is generated by Intel AMT and sent to the LANDesk core server. The core server  
will then issue a System Defense policy to the client that will stop all network traffic except for LANDesk  
management traffic, Intel AMT traffic, DNS traffic, and DHCP traffic, thus isolating the client system  
from the network except for system management functions.  
Using LANDesk* Out-of-Band Monitor (AMTMON) Features:  
LANDesk 8.8 has the ability to disable the network on the client at the OS level. This is not done  
through the System Defense feature, but rather through LANDesk agents and communication via the  
Intel AMT non-volatile memory (NVM) area. When you select to disable or enable the network on that  
client, a flag is set in NVM on the client, which is monitored by the service LANDesk* Out-of-Band  
Monitor (AMTMON.EXE). The AMTMON service disables or enables the network on the client based on  
the value of the flag in NVM. AMTMON can also run a vulnerability scan on the client at the next  
restart, if that flag is set. A message dialog is displayed on the client system whenever these three  
operations are performed.  
Note: Do not ping the Intel AMT client to test if the network is disabled,; Intel AMT will still respond to  
pings.  
System Defense (SD):  
System Defense (SD) does not require any agents to be installed on the Intel AMT client machine.  
System Defense policies may be configured on a per-machine basis.  
There are four pre-defined SD policies:  
An FTP access policy which will trigger SD if an FTP access is made either to or from the Intel  
AMT client machine.  
30  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
A UDP flood policy which will trigger SD if Intel AMT sees at least 20,000 UDP packets per second  
and will monitor for a Denial-of-service attack.  
An SYN flood policy which will trigger SD if Intel AMT sees at least 20,000 IP packets per second  
and will monitor for a Denial-of-service attack.  
A Kill All NICs policy which will stop all network traffic except for LANDesk management, Intel  
AMT, DNS, and DHCP traffic, thus isolating the client system from the network except for system  
management functions.  
Note: In LANDesk 8.8 there is no GUI to create or modify System Defense filters or policies. Currently  
all modifications have to be made to the XML pages used for System Defense.  
Once SD triggers an alert, the alert is displayed in the LSM log. LANDesk and Intel AMT limit network  
access by replacing the current client policy with the Kill All NICs policy when SD is triggered. The client  
machine is also placed in the Remediation queue, which can be found in Configure | Intel vPro  
Options | System Defense | Remediation. Once the machine is remediated, the Kill All NICs policy  
is removed and the previous policy is re-applied. The administrator must manually perform the actual  
remediation of removing the virus or spyware, or fixing whatever caused the SD to be triggered.  
Congratulations! You are now on your way to more productively managing a powerful computer  
system. This can improve your productivity and provide a valuable return on your investment.  
31  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Appendix A: Troubleshooting  
Additional troubleshooting information can be found at the Known Issues, Best Practices, and  
Intel vPro machine not discovered:  
The Intel vPro machine may not have completed the “provisioning cycle” with the LANDesk core server.  
One way to tell this would be to look into the AMTDiscService.Log (AMT discovery service log) which is  
located in the “Program Files / LANDesk / Management Suite” subdirectory. Note: This log file will not  
refresh dynamically when you have it opened. It must be closed and reopened to refresh. If the client  
has properly provisioned, there will be an entry similar to the following:  
Wed, 27 Jun 2007 15:53:42 Incoming Connection from 192.168.0.101:16994  
Wed, 27 Jun 2007 15:53:42 Hostname: client20  
Wed, 27 Jun 2007 15:53:42 Incoming data (32) is:  
Wed, 27 Jun 2007 15:53:42  
Wed, 27 Jun 2007 15:53:42  
Wed, 27 Jun 2007 15:53:42  
Wed, 27 Jun 2007 15:53:42  
Version: 2  
Count : 0  
UUID : F228CDC0-84FB-11DB-915E-0013D4D07748  
PID : PID0009Q  
Wed, 27 Jun 2007 15:53:45 Added to UDD list  
There are a couple of interesting things to point out in this example. First, note that the incoming  
connection is coming from the device’s DHCP address. Next, the hostname will likely be the hostname  
that is registered in DNS for this client. If the hostname is blank in the Management Engine or a  
different hostname exists (in this example the hostname in the ME was iDBO), the hostname passed to  
the LANDesk core server will likely come from the DNS entry.  
The next thing to note is that the PID entry is shown. This helps you to see that the initial  
authentication has been accepted. Note then that the device was added to the UDD (Unmanaged  
Device Discovery). Another entry you could see instead would be:  
Wed, 27 Jun 2007 15:35:19 already in managed list (nodename), info updated  
If you do not see these entries the most likely causes are:  
You have not matched the PID / PPS pre-shared keys between the Intel AMT client and the LANDesk  
core server. The keys generated through the LANDesk System Manager Configure | Intel vPro Options  
| ID Generation must match those you entered into the Intel MEBx.  
You have a mismatched Management Engine password. The password that you entered into the LDMS  
Configure | Services | Intel vPro Configuration tab must match the strong password entered into the  
Intel MEBx. If you entered this manually, make sure you have matched all capitalization, numerals,  
and special characters. If you have used “one-touch” provisioning via the USB key, make sure when  
you generate the keys to be exported (LANDesk Management Suite | Configure | Intel vPro Options |  
32  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Export or Import Intel AMT IDs) that you enter the same password in the field that says “Specify Intel  
vPro ME password (for Intel AMT 2.5 or greater only)”. This needs to be filled in for any Intel vPro  
machine of 2.1 or greater.  
Intel vPro machine was discovered through UDD (Unmanaged Device Discovery) when a network scan  
was run, but the Intel AMT option and Move to Management Database option are grayed out.  
This error will occur if you run a network scan on the segment the Intel vPro machine resides on and it  
has not completed the provisioning process and does not have a LANDesk client agent installed. Use  
the same troubleshooting techniques as listed in troubleshooting item #1  
Intel vPro machine shows up in my managed device inventory, but none of the Intel AMT options are  
available.  
This is another symptom of the Intel vPro machine not completing the provisioning process. Please  
refer to troubleshooting item #1 to resolve  
A second log file is also available to help understand the link between the Intel AMT client, backend  
services (provision server, DNS, DHCP, LDAP and AD) and also LANDesk Management Suite 8.8. The  
second log file shows the actual process between the Intel AMT client, your Domain services, provision  
server and LDMS. In the examples below you can see exactly what is happening between the Client (in  
the provisioning process with RCT) and the backend infrastructure, the first example shows a successful  
provisioning using the RCT process where the Cert and hash were utilized to do the actual provisioning.  
Note the third and fourth entries where the Domain responded with the FQDN and the actual host name  
of the client being provisioned. The rest of the log shows each action and the response from the client.  
The second log file shows a failed provision process and if you look at the third and fourth entries you  
can see that the Domain did not offer the FQDN in the third entry and the fourth line presents with the  
clients IP address instead of the client name. This is a fairly common situation where the Domain does  
not resolve to the client for some reason. Some of the problems here are multiple client names with  
the same IP address in the DNS forward or reverse lookup zones, other problems can be if the DNS and  
DHCP service do not cleanup or resolve released IP addresses. Poor infrastructure (whether  
maintenance or implementation) is the lions share of why provisioning fails, the log files helps point you  
to where the problems are.  
1. From the LDMS VM open Windows Explorer  
2. Select Program Files>LANDesk>Management Suite>AMTPROV  
3. Open the AMTProvMgr2.log  
33  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
An example of Successful Provisioning  
Thu, 28 Feb 2008 113500 LANDesk Intel AMT Provisioning Manager  
Thu, 28 Feb 2008 113500 IP 192.168.0.100  
UUID 44454C4C-FF00-10FF-80FF-FFC04FFF0000  
Thu, 28 Feb 2008 113500 FQDN name for ZTC client1.vprodemo.com  
Thu, 28 Feb 2008 113501 Host Name client1  
Thu, 28 Feb 2008 113501 UUID 44454C4C-FF00-10FF-80FF-FFC04FFF0000  
Thu, 28 Feb 2008 113501 PID no  
Thu, 28 Feb 2008 113501 IP Address 192.168.0.100  
Thu, 28 Feb 2008 113501 user cert 1 exists  
Thu, 28 Feb 2008 113503 soap_ssl_client_context() return 0  
Thu, 28 Feb 2008 113503 Action getCoreVersion  
Thu, 28 Feb 2008 113506 GetCoreVersion passed  
Thu, 28 Feb 2008 113506 Action getHostname  
Thu, 28 Feb 2008 113506 GetHostName passed  
Thu, 28 Feb 2008 113506 AMT hostname in bios [CLIENT1]  
Thu, 28 Feb 2008 113506 Action getDomainname  
Thu, 28 Feb 2008 113506 GetDomainName passed  
Thu, 28 Feb 2008 113506 Action GetPkiCapabilities  
Thu, 28 Feb 2008 113507 GetPkiCapabilities passed  
Thu, 28 Feb 2008 113507 DHCP mode  
Thu, 28 Feb 2008 113507 SetInterfaceSettings passed  
Thu, 28 Feb 2008 113507 LAN SetInterfaceSettings succeeds  
34  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Thu, 28 Feb 2008 113507 Action SetRngKey  
Thu, 28 Feb 2008 113507 SetRngKey passed  
Thu, 28 Feb 2008 113507 Action SetTLSKeyAndCertificate  
Thu, 28 Feb 2008 113507 To generate keys and certificate  
Thu, 28 Feb 2008 113509 Success to generate keys and certificate  
Thu, 28 Feb 2008 113509 SetTLSKeyAndCertificate passed  
Thu, 28 Feb 2008 113509 Action EnumerateTrustedRootCertificates  
Thu, 28 Feb 2008 113509 EnumerateTrustedRootCertificates passed  
Thu, 28 Feb 2008 113509 No trusted root certificates exist  
Thu, 28 Feb 2008 113509 Action SetTlsOptions  
Thu, 28 Feb 2008 113509 SetTlsOptions passed  
Thu, 28 Feb 2008 113509 Action CommitChanges  
Thu, 28 Feb 2008 113510 CommitChanges passed  
Thu, 28 Feb 2008 113510 ProvisioningUnprovisioning process completed successfuly  
35  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
An example of an unsuccessful Provisioning  
Thu, 06 Mar 2008 11:26:23 LANDesk Intel AMT Provisioning Manager  
Thu, 06 Mar 2008 11:26:23 IP: 192.168.0.100 UUID: 44454C4C-4A00-1032-8038-C6C04F514431  
Thu, 06 Mar 2008 11:26:28 Hostname from DNS:  
Thu, 06 Mar 2008 11:26:29 Host Name: 192.168.0.100  
Thu, 06 Mar 2008 11:26:29 UUID: 44454C4C-4A00-1032-8038-C6C04F514431  
Thu, 06 Mar 2008 11:26:29 PID: no  
Thu, 06 Mar 2008 11:26:29 IP Address: 192.168.0.100  
Thu, 06 Mar 2008 11:26:29 user cert 1 exists  
Thu, 06 Mar 2008 11:26:31 soap_ssl_client_context() return: 0  
Thu, 06 Mar 2008 11:26:31 Action: getCoreVersion  
Thu, 06 Mar 2008 11:26:34 GetCoreVersion passed  
Thu, 06 Mar 2008 11:26:34 Action: GetAdminAclEntryStatus  
Thu, 06 Mar 2008 11:26:34 GetAdminAclEntryStatus passed  
Thu, 06 Mar 2008 11:26:34 MEBx password has already been changed, skipping SetMEBxPassword  
Thu, 06 Mar 2008 11:26:34 Action: GetDigestRealm  
Thu, 06 Mar 2008 11:26:34 GetDigestRealm passed  
Thu, 06 Mar 2008 11:26:35 SetAdminAclEntryEx passed  
Thu, 06 Mar 2008 11:26:35 Action: getHostname  
Thu, 06 Mar 2008 11:26:35 GetHostName passed  
Thu, 06 Mar 2008 11:26:35 AMT hostname is not set in bios. Invalid hostname (192.168.0.100) by  
DNS. Hostname is not set  
36  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Thu, 06 Mar 2008 11:26:35 Action: getDomainname  
Thu, 06 Mar 2008 11:26:35 GetDomainName passed  
Thu, 06 Mar 2008 11:26:35 Action: GetPkiCapabilities  
Thu, 06 Mar 2008 11:26:35 GetPkiCapabilities passed  
Thu, 06 Mar 2008 11:26:35 Action: SetEnabledInterfaces  
Thu, 06 Mar 2008 11:26:35 SetEnabledInterfaces passed  
Thu, 06 Mar 2008 11:26:35 Action: SetRedirectionListenerState  
Thu, 06 Mar 2008 11:26:35 GetRedirectionListenerState passed  
Thu, 06 Mar 2008 11:26:35 Current RedirectionListenerState: Disabled. Enable it now  
Thu, 06 Mar 2008 11:26:35 SetRedirectionListenerState passed  
Thu, 06 Mar 2008 11:26:35 Action: setActivePowerPackage  
Thu, 06 Mar 2008 11:26:35 EnumeratePowerPackages passed  
Thu, 06 Mar 2008 11:26:35 SetActivePowerPackage passed  
Thu, 06 Mar 2008 11:26:35 Action: enumerateInterfaces  
Thu, 06 Mar 2008 11:26:35 EnumerateInterfaces passed  
Thu, 06 Mar 2008 11:26:35 Action: setInterfaceSettings  
Thu, 06 Mar 2008 11:26:35 DHCP mode  
Thu, 06 Mar 2008 11:26:35 SetInterfaceSettings passed  
Thu, 06 Mar 2008 11:26:35 LAN: SetInterfaceSettings succeeds  
Thu, 06 Mar 2008 11:26:35 Action: SetRngKey  
Thu, 06 Mar 2008 11:26:35 SetRngKey passed  
Thu, 06 Mar 2008 11:26:35 Action: SetTLSKeyAndCertificate  
Thu, 06 Mar 2008 11:26:35 To generate keys and certificate  
37  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Thu, 06 Mar 2008 11:26:37 Success to generate keys and certificate  
Thu, 06 Mar 2008 11:26:37 SetTLSKeyAndCertificate passed  
Thu, 06 Mar 2008 11:26:37 Action: setNetworkTime  
Thu, 06 Mar 2008 11:26:37 GetLowAccuracyTimeSynch passed  
Thu, 06 Mar 2008 11:26:37 SetHighAccuracyTimeSynch passed  
Thu, 06 Mar 2008 11:26:37 Action: EnumerateTrustedRootCertificates  
Thu, 06 Mar 2008 11:26:37 EnumerateTrustedRootCertificates passed  
Thu, 06 Mar 2008 11:26:37 No trusted root certificates exist  
Thu, 06 Mar 2008 11:26:37 Action: SetTlsOptions  
Thu, 06 Mar 2008 11:26:37 SetTlsOptions passed  
Thu, 06 Mar 2008 11:26:37 Action: CommitChanges  
Thu, 06 Mar 2008 11:26:37 Error: CommitChanges failed (status: 0x0809 res: 0x0000)  
Thu, 06 Mar 2008 11:26:37 Error: SetProvisioningParameters() failed  
38  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Appendix B: Glossary of Terms used in this guide  
PPS: Provisioning Pass phrase. Pre-shared  
key used in provisioning Intel vPro machines.  
BIOS: Basic Input Output System  
DHCP: Dynamic Host Configuration Protocol  
DNS: Domain Name Service.  
PSK: Pre-shared key  
SMB Mode: Small (and Medium) Business  
model used for provisioning an Intel vPro  
machine  
Enterprise Mode: Provisioning model used  
for larger organizations  
TLS: Transport Layer Security  
Intel® AMT: Intel® Active Management  
Technology allows Web Service calls to Intel  
desktops and notebook clients for out-of-band  
management and services.  
Intel® Centrino® Pro processor  
technology: Intel processor technology that  
provides a higher level of security and  
management to mobile computers.  
Intel® ME: Intel® Management Engine  
Intel® MEBx: Intel® Management Engine  
BIOS Extension  
Intel® vPro™ Processor Technology: Intel  
processor technology that provides a higher  
level of security and management to desktop  
computers.  
ISV: Independent Software Vendor  
LMS: Local Management Service driver.  
Provides an interface enabling local  
management software agents to communicate  
with the Intel Management Engine using the  
same high-level protocols as those used for  
remote management (e.g. XML, SOAP).  
OEM: Original Equipment Manufacturer.  
Notation used to designate the PC  
manufacturer.  
PID: Provisioning ID. First portion of security  
key used in provisioning Intel vPro machines.  
PKI: Public Key Infrastructure  
PKI CH: Public Key Infrastructure –  
Certification Hash  
39  
   
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
Intel® vPro™ and Intel® Centrino® Pro Processor Technology Quick Start Guide  
*Other names and brands may be claimed as the property of  
others.  
Intel® Active Management Technology requires the computer  
system to have an Intel® AMT-enabled chipset, network  
hardware and software, as well as connection with a power  
source and a corporate network connection. Setup requires  
configuration by the purchaser and may require scripting with  
the management console or further integration into existing  
security frameworks to enable certain functionality. It may  
also require modifications of implementation of new business  
processes. With regard to notebooks, Intel AMT may not be  
available or certain capabilities may be limited over a host OS-  
based VPN or when connecting wirelessly, on battery power,  
sleeping, hibernating or powered off. For more information,  
Copyright © 2008 Intel Corporation. All rights reserved.  
Intel®, the Intel logo, Intel. Leap ahead™, the Intel Leap ahead™  
Logo, Centrino®, the Centrino® logo, Intel® Core™, vPro™, the  
vPro™ logo, Intel SpeedStep™, Pentium®, and Celeron® are  
registered trademarks of Intel Corporation in the United States  
and other countries.  
.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN  
Intel Corporation may have patents or pending patent  
applications, trademarks, copyrights, or other intellectual  
property rights that relate to the presented subject matter.  
The furnishing of documents and other materials and  
information does not provide any license, express or implied,  
by estoppel or otherwise, to any such patents, trademarks,  
copyrights, or other intellectual property rights.  
Intel may make changes to specifications and product  
descriptions at any time, without notice.  
CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS  
OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY  
INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS  
DOCUMENT. EXCEPT AS PROVIDED IN INTEL’S TERMS AND  
CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES  
NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY  
EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR  
USE OF INTEL PRODUCTS INCLUDING LIABILITY OR  
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR  
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY  
PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY  
RIGHT. UNLESS OTHERWISE AGREED IN WRITING BY INTEL,  
THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED  
FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL  
PRODUCT COULD CREATE A SITUATION WHERE PERSONAL  
INJURY OR DEATH MAY OCCUR.  
Intel® Active Management Technology requires the platform to  
have an Intel® AMT-enabled chipset, network hardware and  
software, connection with a power source, and a network  
connection.  

ITT 29 100 1 ST User Manual
JVC AV 21VS14 User Manual
JVC AV 28BT80EP User Manual
JVC PD Z42DV4 User Manual
LG Electronics LG Life Good Computer Monitor M198WA User Manual
Magnavox 20MT1336 User Manual
Philips 25PT4632 User Manual
Philips DVP3980 User Manual
Philips LCD Monitors User Manual
Philips MCD750 User Manual