SPECIFICATIONS  
Standards  
IMO Resolution A.817(19), IEC 61174 ed2  
Power Supply  
Display Unit:  
Display Unit  
FEA-2107: MU-201CE, 20.1" color LCD, SXGA (1280 x 1024 pixels)  
FEA-2807: MU-231CE, 23.1" color LCD, UXGA (1600 x 1200 pixels)  
Windows XP  
IHO/S-57 v.3 vector chart, ARCS raster chart, C-MAP CM93 ed3*  
*available in the near future  
100 - 230 VAC, 1 ø, 50/60 Hz  
100 - 230 VAC, 1 ø, 50/60 Hz  
24 VDC  
Processor Unit:  
LAN Adapter:  
B Adapter:  
Operating System  
Useable Charts  
24 VDC  
Environment (IEC 60945 test method)  
Presentation Modes  
True/Relative Motion Noth-up, True/Relative Motion Course-up  
Relative Motion Head-up, Relative Motion Route-up  
Temperature  
-
+
All Units:  
15˚C to 55˚C  
Display of data  
Own ship :  
Route :  
Equipment List  
Position, SOG, COG, Heading  
Planned route, Monitoring route  
Standard  
1. Display Unit FEA-2107: MU201CE, FEA-2807: MU-231CE 1 unit  
2. Control Head RCU-018 or  
Trackball Control Unit RCU-015 (Specify when ordering) 1 unit  
3. Processor Unit EC-1000C  
ARPA targets :  
Others :  
Range, Bearing, Speed, Course, CPA and TCPA  
EBL, VRM, Parallel index line, Cursor position, Navigation  
and pilot data notebook  
1 unit  
1 unit  
1 pc  
1 pc  
1 pc  
1 pc  
1 pc  
1 set  
Route/Waypoint  
Route: more than 100 routes  
4. LAN Adapter EC-1010  
Waypoints: 200 waypoints /route  
5. Power Supply Cable for Processor Unit, 1.5 m  
6. Power Supply Cable for Display Unit, 1.5 m  
7. DVI Cable between Display Unit and Processor Unit, 5 m  
8. Cable between Control Unit and Processor Unit, 10 m  
9. LAN Cable, 2 m  
10. Standard Spare Parts and Installation Materials  
Option  
1. LAN Adapter EC-1010  
2. B Adapter EC-1020 for equipment with analog interface  
3. Remote Control Unit RCU-016  
4. Cable between Control Unit and  
Remote Control Unit 03S9610, 1.5/10/20/30 m  
5. Hub HUB-100  
6. Radar Overlay Kit for FAR-21x5 series and FAR-28x5 series  
7. Video Card for Conning Display Unit  
8. Cable between Control Unit and Processor Unit, 20/30 m  
9. DVI Cable between Display Unit and Processor Unit, 10 m  
10. Armored LAN Cable OP03-186-10/20/30  
11. Printer PP-510  
Voyage Calculation  
The following data can be calculated  
Range/Bearing to destination, TTG, ETA, Fuel consumption  
Route Navigation Monitoring Off track, Waypoint, Arrival, Grounding, Depth  
Alarms  
Off track, Channel limit, Waypoint approach, Depth  
Other Functions  
Night/day presentation colors, ARPA target display, Radar overlay,  
User chart function, Position optimization, MOB, Log book,  
Pilot data function, Track control system (TCS)*  
* Please contact the local dealers in your area for details.  
Interface  
Input/output  
AIS :  
IEC 61162-2 (ABM, BBM)  
Radar signal :  
Input  
Ethernet 100 Base-TX or RAW Video  
Gyrocompass :  
IEC 61162-1 (HDT) or Synchro  
SDME (Speed log) : IEC 61162-1 (VBW) or Pulse type  
EPFS :  
Echo Sounder :  
Anemometer :  
IEC 61162-1 (GLL, GGA, VTG, ZDA, DTM)  
IEC 61162-1 (DBT, DPT)  
IEC 61162-1 (MWV)  
Water temp Indicator : IEC 61162-1 (MTW)  
12. USB-Parallel Printer Cable for PP-510  
13. Hand Grip  
14. Bracket  
Current Indicator :  
Output  
IEC 61162-1 (VDR)  
15. Connection Stand  
16. Pedestal slim/standard Type  
Alarms :  
Printer :  
Relay output  
Parallel  
Option  
Shipyard Supply  
INTERCONNECTION DIAGRAM  
AIS  
Control Unit  
Display Unit  
MU-201CE/  
231CE  
LAN Adapter  
EC-1010  
Serial  
Track Pilot *  
250V-TTYCS  
AMWSS  
Route Backup  
GPS Navigator  
Anemometer  
Echo Sounder  
Log/Dual Axis Log  
Gyrocompass  
Engine Control  
Water Temp Indicator  
Alarms  
Ethernet 2.5 m  
RCU-018  
or  
With 8 ports  
5/10 m  
Processor Unit  
EC-1000C  
Ethernet  
10/20/30m  
*
Up to two LAN  
adapters connectable  
HUB  
HUB-100  
24 VDC  
10/20/30 m  
1.5 m  
10/20/30m  
250V-TTYCS-1T  
RCU-015  
x2  
HUB  
HUB-100  
Gyrocompass (Synchro)  
Log (200 p/nm)  
Alarms  
ECDIS for 2nd station  
B Adapter  
1.5 m  
250V-  
5 m  
x8  
x8  
EC-1020  
Radar/ARPA*  
FAR-21x7series  
FAR-28x7series  
Conning Monitor  
TTYCS-1  
20.1" color LCD  
23.1" color LCD  
With18 ports  
Printer  
PP-510  
Analog Sensors  
Remote Control Unit  
RCU-016  
250V-TTYCS/  
MPYC  
*Up to four systems can  
be connected  
24 VDC  
100-230 VAC  
Digitizer  
*Please contact the local dealers in your area for details.  
Display Unit  
Processor Unit  
Trackball Control Unit  
MU-201CE 18.3 kg 40.4 lb  
EC-1000C 15 kg 33.1 lb  
RCU-015 2.4 kg 5.3 lb  
6-  
8
534 21.0"  
506 19.9"  
110 4.3"  
4-  
4
Bracket  
(option)  
35 1.4"  
50 2.0"  
160 6.3"  
526 20.7"  
Hand Grip  
(option)  
287 11.3"  
352 13.9"  
490 19.3"  
570 22.4"  
440 17.3"  
470 18.5"  
89 3.5"  
179 7.1"  
Control Head  
Remote Control Unit  
MU-231CE 23.5 kg 51.8 lb  
RCU-018 3.7 kg 8.2 lb  
RCU-016 2.4 kg 5.3 lb  
598 23.5"  
110 4.3"  
4-  
4
Bracket  
(option)  
308 12.1"  
398 15.7"  
4-  
4
39 1.5"  
54 2.1"  
92 3.6"  
35 1.4"  
50 2.0"  
89 3.5"  
160 6.3"  
287 11.3"  
352 13.9"  
590 23.2"  
Hand Grip  
(option)  
554 21.8"  
TRADE MARK REGISTERED MARCA REGISTRADA  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  
05015U Printed in Japan  
FURUNO U.S.A., INC.  
Camas, Washington, U.S.A.  
Phone: +1 360-834-9300  
Fax: +1 360-834-9400  
FURUNO ESPAÑA S.A.  
Madrid, Spain  
Phone: +34 91-725-90-88  
Fax: +34 91-725-98-97  
FURUNO SVERIGE AB  
Västra Frölunda, Sweden  
Phone: +46 31-7098940  
Fax: +46 31-497093  
FURUNO (UK) LIMITED  
Denmead, Hampshire, U.K.  
Phone: +44 2392-230303  
Fax: +44 2392-230101  
FURUNO DANMARK AS  
Hvidovre, Denmark  
Phone: +45 36 77 45 00  
Fax: +45 36 77 45 01  
FURUNO FINLAND OY  
Espoo, Finland  
Phone: +358 9 4355 670  
Fax: +358 9 4355 6710  
The future today with FURUNO's electronics technology.  
Catalogue No. L-161b  
FURUNO FRANCE S.A.  
Bordeaux-Mérignac, France  
Phone: +33 5 56 13 48 00  
Fax: +33 5 56 13 48 01  
FURUNO NORGE A/S  
Ålesund, Norway  
Phone: +47 70 102950  
Fax: +47 70 127021  
FURUNO POLSKA Sp. Z o.o.  
Gdynia, Poland  
Phone: +48 58 669 02 20  
Fax: +48 58 669 02 21  
9-52 Ashihara-cho, Nishinomiya City, Japan Phone: +81 (0)798 65-2111  
Fax: +81 (0)798 65-4200, 66-4622 URL: www.furuno.co.jp  
TRADE MARK REGISTERED  
MARCA REGISTRADA  
F
E
A T  
U
R
E
S
o
f
E
C
D
I
S
sThe electronic chart can be overlaid with a variety of navigation data such as Radar echo  
images, ship’s position, heading, speed and others to facilitate safe and efficient navigation.  
sCompatible with ENC (S57 Edition 3) charts, ARCS charts and C-MAP CM93 ed3*  
*available in the near future  
sComplies with the following IMO and IEC regulations:  
• IMO A.817(19)  
• IMO MSC.64(67) Annex 5  
• IMO A.694(17)  
• IEC 60945 edition 4  
• IEC 61162-2 edition 1  
• IMO MSC.86(70) Annex 4  
• IEC 61174 edition 2  
• IEC 61162-1 edition 2  
ENC IHO S57 Edition 3  
sFlexible expandability allows the ECDIS to be networked with radar/ARPA, positioning  
equipment, autopilot and others to consolidate the navigation system  
sDisplays 200 AIS targets  
sHigh-resolution color LCD  
When connected to an optional AIS transponder,  
the FEA-2107/2807 can store up to 1,000 AIS  
targets information in its storage buffer, and  
displays up to 200 AIS targets within the user-  
defined range on the display. This provides  
operators with another solution for observation  
of other craft.  
The use of 20.1"/23.1" high-resolution SXGA/UXGA LCDs  
provide crystal clear presentations of navigation  
information, such as marks, lines and waypoints.  
The LCDs also allows for installation where space is limited.  
sErgonomically designed control panel provides  
ease-of-use  
The ergonomically designed control panel consists of  
a trackball, a thumbwheel and a keyboard. The logically  
arranged keyboard provides intuitive operation. Optionally,  
the compact control head only with a trackball and  
a thumbwheel is available for space-saving installation.  
Sleeping AIS Target Activated Target Selected Target  
Lost Target  
Dangerous Target  
sStreamlined design  
A f l e x i b l e E t h e r n e t n e t w o r k  
a l l o w s f o r f u t u r e e x p a n d a b i l i t y  
The color scheme of the optional  
pedestal is a stylish pearl white and  
gray.The streamline design fits  
perfectly in the modern bridge.  
Optional pedestal  
Palm control unit  
sUser-customizable chart drawing function sNavigation data for the past 12 hours  
can be recorded  
(The data to be recorded includes: time, ship’s position,  
GPS correction data, ship’s heading, ship’s speed)  
sRoute planning applicable to both  
Mercator’s sailing and great-circle sailing  
sTrue Motion and Relative Motion modes are  
available  
sTrack Control System when connected  
with autopilot (Option)  
sNavigation data is shared within an Ethernet network  
The 100 Base-T Ethernet is utilized to link  
this ECDIS with up to four sets of radar/ARPA  
FAR-21x7/28x7. This link gives high-speed  
navigational data sharing within the system  
and allows operators to choose either a single  
station system or a total Integrated Navigation  
System (INS).  
Ethernet 100 Base-TX  
Autopilot  
SDME  
GPS Navigator  
P
R
E
S
E
N
T A T  
I
O
N
S
o
f
E
C
D
I
S
N a v i g a t e s a f e l y a n d e f f i c i e n t l y w i t h  
t h e E C D I S r o u t e p l a n n i n g a n d m o n i t o r i n g  
Status bar  
Presentation mode  
Own ships information  
Ships position  
Heading  
Course over ground (COG)  
Speed over ground (SOG)  
Vector mode and vector time  
Planned route, chart name  
Name of pilot data  
Radar overlay  
Radar echo image overlay is optionally available in  
the FEA-2107/2807. This function gives the exact match in  
scale and presentation of the chart and radar echo image.  
This greatly helps the operators observation and enhances  
their accuracy.  
Source of target data  
Predictor time  
AIS information  
Heading  
Cursor  
Name  
Course  
IMO MMSI number CPA  
Position  
Speed  
TCPA  
Range  
Own ships marker  
AIS symbol  
UTC  
(coordinated universal time)  
Planned route  
Cursor information,  
Distance and bearing  
between own ship  
and cursor  
WTP  
(Waypoint)  
Buoy  
Route planning  
The operators can plan and  
determine the precise route with  
ease, while studying the chart  
data on the screen. A route can  
be altered in minute detail, and  
the changed route can be saved  
for later use.  
Radar overlay dialog box  
Operators can have controls for  
adjustment of the radar image - gain, sea  
clutter, rain clutter, echo trail, interference  
rejector, echo stretch and noise rejector.  
Conning display  
A variety of navigation  
information, which is input  
from up to sixteen onboard  
sensors, can be graphically  
displayed on thee screen.  
Up to eight sensors provide  
the analog data, and the other  
eight provide the serial data.  
The information is displayed in six predefined place  
where the operators can arrange the layout.  
Typically, information on the conning display is received  
from the following sensors:  
sPosition sensors sRate of turn gyro sRudder  
sWind sensor  
sGyro  
sLog/Dual-axis log sPropellers  
sEcho sounder sThrusters  
Day/night presentation  
Data display  
Antigrounding  
When the cursor is placed upon any mark on the electronic  
chart, related information about the object such as a buoy,  
lighthouse, sunken vessel, etc., will be shown in the data  
cell. Additionally, other navigational information including  
both own ships navigational as well as other ships  
information from ARPA can also be presented.  
This function informs the operator beforehand of shallow  
coastal water and other sea conditions that could  
contribute to the ship going aground.  
The information about the sea areas is acquired from  
the electronic chart and ships draft data is preset in own  
ships information so that possible strand can be avoided.  

Hotpoint GW38P User Manual
Hitachi PW1 User Manual
Heath Zenith SL 4300 User Manual
GE EPM 5300 User Manual
GEA Nu Con Cooktop JGP656 User Manual
Fujitsu Mainboard D1562 User Manual
Electra Accessories EL 305C User Manual
Dell E207WFP User Manual
Cypress NoBL CY7C1472BV25 User Manual
Asus P5N7A VM User Manual