Preface  
Fujitsu would like to thank you for purchasing our ETERNUS DX80 S2/DX90 S2 Disk storage system.  
The ETERNUS DX80 S2/DX90 S2 Disk storage system is designed to be connected to Fujitsu (PRIMEQUEST or  
PRIMERGY) or non-Fujitsu servers.  
This manual describes the environmental requirements that are necessary to install and use the ETERNUS  
DX80 S2/DX90 S2 Disk storage system.  
This manual is intended for use of ETERNUS DX80 S2/DX90 S2 Disk storage system in regions other than Japan.  
Please carefully review the information outlined in this manual.  
Twelfth Edition  
June 2013  
Microsoft, Windows, Windows Server, and Internet Explorer are either registered trademarks or trademarks of  
Microsoft Corporation in the United States and/or other countries.  
Mozilla, Firefox, and the Mozilla and Firefox logos are trademarks or registered trademarks of the Mozilla  
Foundation in the United States and other countries.  
The company names, product names and service names mentioned in this document are registered  
trademarks or trademarks of their respective companies.  
3
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
About this Manual  
Organization  
This manual is composed of the following four chapters:  
This chapter describes the main components and the relative optional products that are installed in the  
ETERNUS DX80 S2/DX90 S2 Disk storage system.  
This chapter describes the installation specifications, the installation environment, and the power  
requirements.  
This chapter describes the configuration for each interface to connect to the ETERNUS DX80 S2/DX90 S2  
Disk storage system.  
This chapter describes the requirements for rack installation.  
This chapter also describes the standard installation rules (installation locations and installation order) of  
the optional products before shipment from the factory when the optional products are purchased with the  
ETERNUS DX80 S2/DX90 S2 Disk storage system at the same time.  
Naming Conventions  
Abbreviations used in this manual  
"ETERNUS DX Disk storage system" refers to the ETERNUS DX80 S2/DX90 S2 Disk storage system.  
"CA" refers to a host interface module that is used in an ETERNUS DX Disk storage system to connect to a  
server.  
"Host Bus Adapter (HBA)" refers to the interface module that is normally used by the server to connect to  
ETERNUS DX Disk storage systems.  
An "FC card", "LAN card", "Network Interface Card (NIC)", "Converged Network Adapter (CNA)", or "SAS card"  
may be used instead, depending on the server and interface.  
Trademark symbols such as ™ and ® are omitted in this document.  
4
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
About this Manual  
Warning Notations  
Warning signs are shown throughout this manual in order to prevent injury to the user and/or material  
damage. These signs are composed of a symbol and a message describing the recommended level of caution.  
The following explains the symbol, its level of caution, and its meaning as used in this manual.  
This symbol indicates the possibility of minor or moderate personal injury, as well  
as damage to the ETERNUS DX Disk storage system and/or to other users and their  
property, if the ETERNUS DX Disk storage system is not used properly.  
CAUTION  
How Warnings are Presented in this Manual  
A message is written beside the symbol indicating the caution level. This message is marked with a vertical  
ribbon in the left margin, to distinguish this warning from ordinary descriptions.  
An example is shown here.  
Warning Level Indicator  
Example Warning  
Warning Type Indicator  
Warning Details  
To avoid damaging the ETERNUS DX Disk storage system,  
pay attention to the following points when cleaning the ETERNUS DX  
Disk storage system:  
-
Make sure to disconnect the power when cleaning.  
-
Be careful that no liquid seeps into the ETERNUS DX Disk storage  
system when using cleaners, etc.  
-
Do not use alcohol or other solvents to clean the ETERNUS DX Disk  
storage system.  
Warning Layout Ribbon  
5
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Table of Contents  
6
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Table of Contents  
7
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
List of Figures  
Figure 3.7  
Example of non-supported connection configuration (when multiple types of  
Example of supported connection configuration (when multiple types of  
Figure 3.8  
8
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
List of Figures  
9
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
List of Tables  
Table 1.8  
Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection) and  
Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection) and  
Table 1.9  
Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection) and  
Table 1.10  
Specifications for power cords supplied with the ETERNUS DX Disk storage system  
Table 2.4  
Specifications for power cords supplied with the ETERNUS DX Disk storage system  
Table 2.5  
Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U,  
Table 2.7  
Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U,  
Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U,  
Table 2.8  
Table 2.9  
10  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Chapter 1  
Hardware Configurations  
This chapter explains hardware configurations for the ETERNUS DX Disk storage system.  
1.1  
Controller Enclosure  
This section explains the main components in the controller enclosure.  
The controller enclosure contains drives installed in the front, and controllers and power supply units in the  
rear.  
Since the power supply units are redundant, operations can continue even if one of them fails. There are two  
models: a single-controller type and a dual-controller type. For a dual-controller type, operations can continue  
even if one of the controllers fails.  
The single-controller type differs from the dual-controller type by the following features:  
- The controller and I/O module are not duplicated.  
- Hot maintenance or swapping of the controller and I/O module is not possible.  
- Concurrent firmware loading or update of the controller firmware and I/O module firmware is not  
possible.  
- Multipath connection to a single server is not available.  
- The Thin Provisioning function cannot be used.  
- The Flexible Tier function cannot be used.  
Fujitsu recommends that the dual-controller types, in which the controller and I/O module are duplicated,  
be used in a system where a high level of reliability is required.  
External views of a 2.5" type controller enclosure  
Front view  
Figure 1.1 Front view of a 2.5" type controller enclosure  
2.5" disk or 2.5" Solid State Drive (SSD)  
11  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 1 Hardware Configurations  
1.1 Controller Enclosure  
Rear view  
Single-controller type  
Figure 1.2 Rear view of a 2.5" type controller enclosure (single-controller type)  
Host interface (CA#1)  
LAN (RMT) port LAN (MNT) port  
Controller (CM#0)  
PWC port  
Cover  
Power supply unit (PSU#0)  
Drive interface (OUT) port  
Power supply unit (PSU#1)  
Host interface (CA#0)  
Dual-controller type  
Figure 1.3 Rear view of a 2.5" type controller enclosure (dual-controller type)  
Host interface (CA#1)  
Host interface (CA#1)  
LAN (RMT) port LAN (MNT) port  
Controller (CM#1)  
PWC port  
LAN (RMT) port LAN (MNT) port  
Controller (CM#0)  
PWC port  
Power supply unit (PSU#0)  
Power supply unit (PSU#1)  
Drive interface (OUT) port  
Host interface (CA#0)  
Drive interface (OUT) port  
Host interface (CA#0)  
12  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 1 Hardware Configurations  
1.1 Controller Enclosure  
Top view  
Figure 1.4 Top view of a 2.5" type controller enclosure  
Side view  
Figure 1.5 Side view of a 2.5" type controller enclosure  
External views of a 3.5" type controller enclosure  
Front view  
Figure 1.6 Front view of a 3.5" type controller enclosure  
3.5" disk or 3.5" Solid State Drive (SSD)  
13  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.1 Controller Enclosure  
Rear view  
Single-controller type  
Figure 1.7 Rear view of a 3.5" type controller enclosure (single-controller type)  
Host interface (CA#1)  
LAN (RMT) port LAN (MNT) port  
Controller (CM#0)  
PWC port  
Cover  
Power supply unit (PSU#0)  
Drive interface (OUT) port  
Power supply unit (PSU#1)  
Host interface (CA#0)  
Dual-controller type  
Figure 1.8 Rear view of a 3.5" type controller enclosure (dual-controller type)  
Host interface (CA#1)  
Host interface (CA#1)  
LAN (RMT) port LAN (MNT) port  
Controller (CM#1)  
PWC port  
LAN (RMT) port LAN (MNT) port  
Controller (CM#0)  
PWC port  
Power supply unit (PSU#0)  
Power supply unit (PSU#1)  
Drive interface (OUT) port  
Host interface (CA#0)  
Drive interface (OUT) port  
Host interface (CA#0)  
14  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 1 Hardware Configurations  
1.1 Controller Enclosure  
Top view  
Figure 1.9 Top view of a 3.5" type controller enclosure  
Side view  
Figure 1.10 Side view of a 3.5" type controller enclosure  
1.1.1  
Controllers  
The controller contains a CPU, cache memory, System Capacitor Unit (SCU), non-volatile memory, host  
interfaces, drive interface ports, and LAN ports. The controller controls all operations in the ETERNUS DX Disk  
storage system.  
CPU  
A single core processor is installed.  
Cache memory  
Cache memory enables high speed processing by storing frequently used data.  
The cache memory capacity for each controller is 2GB for the ETERNUS DX80 S2 and 4GB for the ETERNUS DX90  
S2.  
15  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.1 Controller Enclosure  
Host interfaces  
A host interface (CA) is a board that has interface ports to connect a controller to a server.  
Up to two host interfaces can be installed in the controller of an ETERNUS DX Disk storage system. Different  
types of host interfaces can exist together in the same controller. For details about the installation rules, refer  
FC, iSCSI, FCoE, and SAS are available as host interface.  
The following table shows the host interface specifications.  
Table 1.1 Host interface specifications  
Interface  
Transfer speed (max.)  
16Gbit/s  
Connector type  
Number of ports for each CA  
FC  
LC  
2
8Gbit/s  
iSCSI  
10Gbit/s  
LC  
2
2
2
2
SFP+  
(direct attach twinax copper)  
1Gbit/s  
RJ-45  
LC  
FCoE  
SAS  
10Gbit/s  
SFP+  
(direct attach twinax copper)  
6Gbit/s  
miniSAS (SFF-8088)  
FC and iSCSI host interfaces can be used as remote interfaces for remote connections by changing the port  
mode. The port mode can be set from ETERNUS Web GUI or ETERNUS CLI.  
There are two types of iSCSI 10Gbit/s and FCoE host interfaces; an interface type with SFP+ modules (LC  
connector for an FC cable connection) and an interface type without SFP+ modules (SPF+ connector for a  
Copper Twinax cable connection).  
For SFP+ modules, Short Wave Length (SWL) or Long Wave Length (LWL) types can be installed in  
16Gbit/s FC interfaces. The default modules that are installed in 16Gbit/s FC interfaces are SWL type SFP+  
modules. To install LWL type SFP+ modules, purchase the Long wave SFP+ modules for the DX80 S2/DX90  
S2 separately.  
Drive interface ports  
A drive interface port is used to connect drive enclosures.  
The following table shows the drive interface port specifications.  
Table 1.2 Drive interface port specifications for controllers  
Interface  
Transfer speed (max.)  
6Gbit/s  
Connector type  
QSFP  
Number of ports for each controller  
1
SAS  
16  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 1 Hardware Configurations  
1.1 Controller Enclosure  
LAN ports  
Two LAN ports (RJ-45) are installed in each controller.  
Each LAN port is used for operation management (MNT port) and for remote support function (RMT port)  
respectively.  
The following table shows the LAN port specifications.  
Table 1.3 LAN port specifications for controllers  
Transfer speed  
(max.)  
Number of ports  
for each controller  
Interface  
Connector type  
RJ-45  
Ethernet  
(1000Base-T/100Base-TX/10Base-T)  
1Gbit/s  
2
SCU  
A System Capacitor Unit (SCU) is installed in a controller as a backup power source in case of power outage.  
The SCU is charged from an external power source while the ETERNUS DX Disk storage system is running nor-  
mally. If a power failure is detected, data in the cache memory is saved to the non-volatile memory in the con-  
troller using the SCU. There is no limit to the post-failure data retention time.  
PWC ports  
A PWC port is installed in a controller.  
The PWC port is used to connect a power synchronized unit to perform power synchronization.  
The following table shows the PWC port specifications.  
Table 1.4 PWC port specifications  
Interface  
Connector type  
PWC  
Number of ports for each controller  
1
RS232C  
1.1.2  
Power Supply Units  
The power supply unit transforms input AC power from a power socket to DC power and supplies power to each  
component. Two power supply units are installed in each controller enclosure.  
Each power supply unit contains fans.  
17  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.2 Drive Enclosures  
1.2  
Drive Enclosures  
This section explains the main components in the drive enclosure.  
The drive enclosure contains drives installed in the front, and I/O modules and power supply units in the rear.  
Up to 24 drives can be installed in a 2.5" type drive enclosure. Up to 12 drives can be installed in a 3.5" type  
drive enclosure.  
Since the power supply units are redundant, operations can continue even if one of them fails.  
When a drive enclosure is connected, a DE-ID (drive enclosure number) is automatically allocated.  
External views of a 2.5" type drive enclosure  
Front view  
Figure 1.11 Front view of a 2.5" type drive enclosure  
2.5" disk or 2.5" Solid State Drive (SSD)  
DE-ID display panel  
Rear view  
Single-IOM type  
Figure 1.12 Rear view of a drive enclosure (single-IOM type)  
Drive interface (OUT) port  
Drive interface (IN) port  
I/O module  
(IOM6#0)  
Cover  
Power supply  
unit (PSU#1)  
Power supply unit (PSU#0)  
18  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.2 Drive Enclosures  
Dual-IOM type  
Figure 1.13 Rear view of a drive enclosure (dual-IOM type)  
Drive interface (OUT) port  
Drive interface (IN) port  
Drive interface (OUT) port  
Drive interface (IN) port  
I/O module  
(IOM6#0)  
I/O module  
(IOM6#1)  
Power supply  
unit (PSU#1)  
Power supply unit (PSU#0)  
Top view  
Figure 1.14 Top view of a 2.5" type drive enclosure  
Side view  
Figure 1.15 Side view of a 2.5" type drive enclosure  
19  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.2 Drive Enclosures  
External views of a 3.5" type drive enclosure  
Front view  
Figure 1.16 Front view of a 3.5" type drive enclosure  
3.5" disk or 3.5" Solid State Drive (SSD)  
DE-ID display panel  
Rear view  
Single-IOM type  
Figure 1.17 Rear view of a drive enclosure (single-IOM type)  
Drive interface (OUT) port  
Drive interface (IN) port  
I/O module  
(IOM6#0)  
Cover  
Power supply  
unit (PSU#1)  
Power supply unit (PSU#0)  
Dual-IOM type  
Figure 1.18 Rear view of a drive enclosure (dual-IOM type)  
Drive interface (OUT) port  
Drive interface (IN) port  
Drive interface (OUT) port  
Drive interface (IN) port  
I/O module  
(IOM6#0)  
I/O module  
(IOM6#1)  
Power supply  
unit (PSU#1)  
Power supply unit (PSU#0)  
20  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.2 Drive Enclosures  
Top view  
Figure 1.19 Top view of a 3.5" type drive enclosure  
Side view  
Figure 1.20 Side view of a 3.5" type drive enclosure  
1.2.1  
I/O Modules  
The I/O module is a component that controls the interaction between the controller and the drives.  
The I/O module is connected to the controller or an I/O module on another drive enclosure.  
Drive interface ports  
A drive interface port is used to connect a controller enclosure or drive enclosures.  
The drive interface port has an IN port and an OUT port.  
The following table shows the drive interface port specifications.  
Table 1.5 Drive interface port specifications for I/O modules  
Interface  
Transfer speed (max.)  
6Gbit/s  
Connector type  
QSFP  
Number of ports for each I/O module  
1 (IN)  
1 (OUT)  
SAS  
21  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 1 Hardware Configurations  
1.3 Enclosure Connection Path  
1.2.2  
Power Supply Units  
The power supply unit transforms input AC power from a power socket to DC power and supplies power to each  
component. Two power supply units are installed in each drive enclosure.  
Each power supply unit contains fans.  
1.3  
Enclosure Connection Path  
For a dual-controller type, a controller enclosure (CE) is connected to drive enclosures (DE) with multiple  
paths.  
A drive enclosure has two independent drive interface ports. Path redundancy is maintained by connecting  
the drive enclosure to two controllers directly. This configuration allows operation to continue even if one of  
the connection paths fails.  
Up to nine drive enclosures can be connected to a controller enclosure as shown in the figures below.  
Figure 1.21 Enclosure connection path (dual-controller type)  
DE #09  
DI  
DI  
DE #0x  
DE #02  
DI  
DI  
DI  
DI  
DI  
DI  
DI  
DI  
DE #01  
CE  
DI  
DI  
DI: Drive interface port  
22  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.4 Drives  
A connection path is not duplicated in a single-controller type.  
Figure 1.22 Enclosure connection path (single-controller type)  
DE #09  
DI  
DE #0x  
DI  
DE #02  
DI  
DI  
DE #01  
DI  
DI  
CE  
DI: Drive interface port  
1.4  
Drives  
The following drives can be installed in a controller enclosure and drive enclosure.  
1.4.1  
2.5" Drives  
The following table shows the 2.5" drive specifications.  
Table 1.6 2.5" drive specifications  
Drive name  
SAS disks  
Drive interface  
Storage media  
Hard disk  
Storage capacity  
300GB  
Speed  
15,000rpm  
10,000rpm  
300GB, 450GB, 600GB,  
900GB  
SAS self encrypting  
disks (SEDs)  
Serial Attached  
SCSI (6Gbit/s)  
Hard disk  
300GB, 450GB, 600GB,  
900GB  
10,000rpm  
Nearline SAS disks  
SSDs  
Hard disk  
1TB  
7,200rpm  
Flash memory  
100GB, 200GB, 400GB,  
800GB  
23  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 1 Hardware Configurations  
1.5 Power Distribution Units (Only for Regions Other than EMEA&I)  
1.4.2  
3.5" Drives  
The following table shows the 3.5" drive specifications.  
Table 1.7 3.5" drive specifications  
Drive name  
SAS disks  
Drive interface  
Storage media  
Hard disk  
Storage capacity  
300GB, 450GB, 600GB  
1TB, 2TB, 3TB, 4TB  
Speed  
15,000rpm  
7,200rpm  
Nearline SAS disks  
SSDs  
Serial Attached  
SCSI (6Gbit/s)  
Hard disk  
Flash memory  
100GB, 200GB, 400GB,  
800GB  
1.5  
Power Distribution Units (Only for Regions Other than  
EMEA&I)  
There are two sizes for power distribution units: 1U and 2U.  
A power distribution unit is an option to connect power supply units to power outlets when power sockets are  
limited.  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2 enclosures  
connection)  
There are four outlets and two inlets.  
Figure 1.23 Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection)  
Outlets (OUTPUT)  
Inlets (INPUT)  
24  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 1 Hardware Configurations  
1.5 Power Distribution Units (Only for Regions Other than EMEA&I)  
The following table shows the specifications of a power distribution unit and the AC cables that are provided.  
Table 1.8 Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection) and provided AC cable  
specifications  
Item  
Specifications  
Power  
Voltage  
AC200 - 240V  
Single  
Phase  
Frequency  
Connection type  
Length  
50Hz/60Hz  
Input cable  
Output cable  
IEC60320-C13 NEMA L6-15P  
4m  
Quantity  
2
Connection type  
Length  
IEC60320-C13 IEC60320-C14  
3m  
4
Quantity  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures  
connection)  
There are 12 outlets.  
Figure 1.24 Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection)  
Outlets (OUTPUT)  
The following table shows the specifications of a power distribution unit and the AC cables that are provided.  
Table 1.9 Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection) and provided AC cable  
specifications  
Item  
Specifications  
Power  
Voltage  
AC200 - 240V  
Single  
Phase  
Frequency  
Connection type  
Length  
50Hz/60Hz  
Input cable  
Output cable  
Straight-through NEMA L6-20P  
4m  
Quantity  
2
Connection type  
Length  
IEC60320-C13 IEC60320-C14  
3m  
12  
Quantity  
25  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 1 Hardware Configurations  
1.5 Power Distribution Units (Only for Regions Other than EMEA&I)  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8 enclosures  
connection)  
There are 16 outlets.  
Figure 1.25 Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection)  
Outlets (OUTPUT)  
The following table shows the specifications of a power distribution unit and the AC cables that are provided.  
Table 1.10 Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection) and provided AC cable  
specifications  
Item  
Specifications  
Power  
Voltage  
AC200 - 240V  
Single  
Phase  
Frequency  
Connection type  
Length  
50Hz/60Hz  
Input cable  
Output cable  
Straight-through NEMA L6-30P  
4m  
Quantity  
2
Connection type  
Length  
IEC60320-C13 IEC60320-C14  
3m  
16  
Quantity  
26  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 2  
ETERNUS DX Disk Storage System Installation  
This chapter explains the installation of the ETERNUS DX Disk storage system.  
2.1  
Installation Specifications  
2.1.1  
ETERNUS DX80 S2  
The following table shows the specifications of the ETERNUS DX80 S2.  
Table 2.1 ETERNUS DX80 S2 installation specifications  
ETERNUS DX80 S2  
Item  
2.5" drive configuration  
482 × 645 × 88mm (2U)  
482 × 540 × 88mm (2U)  
435 × 148 × 38mm  
(485 × 280 × 43mm) × 2 (*1)  
35kg  
3.5" drive configuration  
482 × 670 × 88mm (2U)  
482 × 555 × 88mm (2U)  
Controller enclosure  
Drive enclosure  
Dimensions  
(W × D × H)  
1U  
2U  
Power  
distribution unit  
Controller enclosure  
Drive enclosure  
35kg  
Maximum  
weight (*2)  
1U  
2U  
2kg  
Power  
distribution unit  
(6kg) × 2 (*1)  
Service area  
Front: 800mm, Rear: 800mm  
AC 100 – 120V, AC 200 – 240V  
Single  
Voltage  
Phase  
Frequency  
50Hz/60Hz  
Number of power supply units  
2 (for each enclosure)  
For AC200V connections:  
IEC60320-C14G (supplied as standard)  
Power  
EMEA&I region  
For AC200V connections:  
Plug type  
Regions other  
than EMEA&I  
NEMA L6-15P (supplied as standard)  
For AC100V/AC200V connections:  
IEC60320-C14 (optional)  
AC 100 – 120V  
AC 200 – 240V  
AC 100 – 120V  
AC 200 – 240V  
630W (640VA)  
630W (640VA)  
570W (580VA)  
570W (580VA)  
620W (630VA)  
Controller  
enclosure  
Maximum power  
requirements  
(*2)  
610W (620VA)  
550W (560VA)  
550W (560VA)  
Drive  
enclosure  
27  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
           
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.1 Installation Specifications  
ETERNUS DX80 S2  
2.5" drive configuration 3.5" drive configuration  
Item  
AC 100 – 120V  
AC 200 – 240V  
AC 100 – 120V  
AC 200 – 240V  
2300kJ/h  
2300kJ/h  
2100kJ/h  
2100kJ/h  
2300kJ/h  
2200kJ/h  
2000kJ/h  
2000kJ/h  
Controller  
enclosure  
Maximum heat  
generation (*2)  
Drive  
enclosure  
3
Maximum  
amount of  
exhaust air  
Controller enclosure  
Drive enclosure  
4.0m /min  
3
4.0m /min  
Operating  
Not operating  
Shipping  
10 – 40°C  
Temperature  
0 – 50°C  
-40 – 60°C  
15°C/Hr or less  
20 – 80%RH  
8 – 80%RH  
8 – 90%RH  
30%/day or less  
29°C  
Temperature gradient  
Operating  
Humidity  
Not operating  
Shipping  
Humidity gradient  
Maximum wet bulb temperature  
Altitude above sea level  
Airborne dust  
Environmental  
conditions  
0 – 3000m  
3
0.15mg/m or less  
Cl2: 3.4ppb or less, H2S: 7.1ppb or less  
SO2: 37ppb or less, NH3: 420ppb or less  
NO2: 52ppb or less, O3: 5ppb or less  
HCl: 6.6ppb or less, HF: 3.6ppb or less  
Gas concentration tolerance level  
3
Oil vapor  
0.2mg/m or less  
If the ETERNUS DX Disk storage system is installed on the  
ocean or premises within 0.5km from the coast, necessary  
measures must be taken to prevent salt corrosion.  
Seawater (salt corrosion)  
Operating  
400gal  
1000gal  
49dB (A)  
6.6B  
Vibration limit  
Not operating  
Sound Pressure Level (LpAm)  
Sound Power Level (LWAd)  
Noise emission  
(*3)  
*1: A 2U power distribution unit is composed of two 1U power distribution units.  
*2: These values are for when each enclosure has twenty-four drives in a 2.5" drive configuration or when each enclo-  
sure has twelve drives in a 3.5" drive configuration.  
*3: These values are measured when a single controller enclosure and drive enclosure are configured in an environment  
in which the temperature is 23 ± 2°C.  
28  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.1 Installation Specifications  
2.1.2  
ETERNUS DX90 S2  
The following table shows the specifications of the ETERNUS DX90 S2.  
Table 2.2 ETERNUS DX90 S2 installation specifications  
ETERNUS DX90 S2  
2.5" drive configuration 3.5" drive configuration  
Item  
Controller enclosure  
Drive enclosure  
482 × 645 × 88mm (2U)  
482 × 540 × 88mm (2U)  
435 × 148 × 38mm  
(485 × 280 × 43mm) × 2 (*1)  
35kg  
482 × 670 × 88mm (2U)  
482 × 555 × 88mm (2U)  
Dimensions  
(W × D × H)  
1U  
2U  
Power  
distribution unit  
Controller enclosure  
Drive enclosure  
35kg  
Maximum  
weight (*2)  
1U  
2U  
2kg  
Power  
distribution unit  
(6kg) × 2 (*1)  
Service area  
Front: 800mm, Rear: 800mm  
AC 100 – 120V, AC 200 – 240V  
Single  
Voltage  
Phase  
Frequency  
50Hz/60Hz  
Number of power supply units  
2 (for each enclosure)  
For AC200V connections:  
IEC60320-C14G (supplied as standard)  
Power  
EMEA&I region  
For AC200V connections:  
Plug type  
Regions other  
than EMEA&I  
NEMA L6-15P (supplied as standard)  
For AC100V/AC200V connections:  
IEC60320-C14 (optional)  
AC 100 – 120V  
AC 200 – 240V  
AC 100 – 120V  
AC 200 – 240V  
AC 100 – 120V  
AC 200 – 240V  
AC 100 – 120V  
AC 200 – 240V  
630W (640VA)  
630W (640VA)  
570W (580VA)  
570W (580VA)  
2300kJ/h  
620W (630VA)  
Controller  
enclosure  
Maximum power  
requirements  
(*2)  
610W (620VA)  
550W (560VA)  
550W (560VA)  
2300kJ/h  
Drive  
enclosure  
Controller  
enclosure  
2300kJ/h  
2200kJ/h  
Maximum heat  
generation (*2)  
2100kJ/h  
2000kJ/h  
Drive  
enclosure  
2100kJ/h  
2000kJ/h  
3
Maximum  
amount of  
exhaust air  
Controller enclosure  
Drive enclosure  
4.0m /min  
3
4.0m /min  
29  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.1 Installation Specifications  
ETERNUS DX90 S2  
2.5" drive configuration 3.5" drive configuration  
Item  
Operating  
Not operating  
Shipping  
10 – 40°C  
Temperature  
0 – 50°C  
-40 – 60°C  
15°C/Hr or less  
20 – 80%RH  
8 – 80%RH  
8 – 90%RH  
30%/day or less  
29°C  
Temperature gradient  
Operating  
Humidity  
Not operating  
Shipping  
Humidity gradient  
Maximum wet bulb temperature  
Altitude above sea level  
Airborne dust  
Environmental  
conditions  
0 – 3000m  
3
0.15mg/m or less  
Cl2: 3.4ppb or less, H2S: 7.1ppb or less  
SO2: 37ppb or less, NH3: 420ppb or less  
NO2: 52ppb or less, O3: 5ppb or less  
HCl: 6.6ppb or less, HF: 3.6ppb or less  
Gas concentration tolerance level  
3
Oil vapor  
0.2mg/m or less  
If the ETERNUS DX Disk storage system is installed on the  
ocean or premises within 0.5km from the coast, necessary  
measures must be taken to prevent salt corrosion.  
Seawater (salt corrosion)  
Operating  
400gal  
1000gal  
49dB (A)  
6.6B  
Vibration limit  
Not operating  
Sound Pressure Level (LpAm)  
Sound Power Level (LWAd)  
Noise emission  
(*3)  
*1: A 2U power distribution unit is composed of two 1U power distribution units.  
*2: These values are for when each enclosure has twenty-four drives in a 2.5" drive configuration or when each enclo-  
sure has twelve drives in a 3.5" drive configuration.  
*3: These values are measured when a single controller enclosure and drive enclosure are configured in an environment  
in which the temperature is 23 ± 2°C.  
30  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.2 Storage System Dimensions  
2.2  
Storage System Dimensions  
2.2.1  
Controller Enclosure Dimensions  
2.5" type controller enclosure  
The following diagrams show the dimensions of a 2.5" type controller enclosure.  
The dimension values do not include any protruding parts (approximation).  
Figure 2.1 2.5" type controller enclosure dimensions  
Side  
482mm  
Top  
Front  
31  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.2 Storage System Dimensions  
3.5" type controller enclosure  
The following diagrams show the dimensions of a 3.5" type controller enclosure.  
The dimension values do not include any protruding parts (approximation).  
Figure 2.2 3.5" type controller enclosure dimensions  
Side  
482mm  
Top  
Front  
32  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.2 Storage System Dimensions  
2.2.2  
Drive Enclosure Dimensions  
2.5" type drive enclosure  
The following diagrams show the dimensions of a 2.5" type drive enclosure.  
The dimension values do not include any protruding parts (approximation).  
Figure 2.3 2.5" type drive enclosure dimensions  
Side  
482mm  
Top  
Front  
33  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.2 Storage System Dimensions  
3.5" type drive enclosure  
The following diagrams show the dimensions of a 3.5" type drive enclosure.  
The dimension values do not include any protruding parts (approximation).  
Figure 2.4 3.5" type drive enclosure dimensions  
Side  
482mm  
Top  
Front  
34  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.3 Package Size  
2.3  
Package Size  
The ETERNUS DX Disk storage system is shipped in cardboard boxes. These boxes may not fit through some  
doorways or elevators. To make sure that the ETERNUS DX Disk storage system can be moved to the  
installation site, carefully check the transport route information. Refer to "2.1 Installation Specifications"  
(page 27) for the maximum weight of each enclosure.  
The following table shows the package size and the maximum package weight of each component for regions  
other than EMEA&I.  
Table 2.3 Package size (for regions other than EMEA&I)  
Component  
Controller enclosure  
Package size (W × D × H)  
600 × 760 × 240mm  
Maximum weight (approx.)  
40kg  
2.5" type  
3.5" type  
2.5" type  
3.5" type  
2.5"  
600 × 780 × 240mm  
600 × 660 × 240mm  
600 × 670 × 240mm  
160 × 278 × 106mm  
189 × 300 × 116mm  
570 × 710 × 160mm  
(390 × 590 × 180mm) × 2  
40kg  
40kg  
Drive enclosure  
Drive (*1)  
40kg  
0.5kg  
1.0kg  
4kg  
3.5"  
1U  
Power distribution unit  
2U  
(7kg) × 2  
*1: When an order for optional drives to be installed in the factory is placed, enclosures are shipped with the drives  
preinstalled. When optional drives are ordered without preinstallation, each drive is shipped in an individual  
package.  
35  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.4 Installation Area  
2.4  
Installation Area  
This section explains the installation area and the service area that are required for an ETERNUS DX Disk  
storage system that is installed in a Fujitsu 19-inch rack.  
Secure service areas that are 800mm or more in the front and rear of the ETERNUS DX Disk storage system.  
The size of the side areas varies depending on the rack specifications.  
Figure 2.5 Installation area and service area  
800mm or more  
Rear service area  
ETERNUS DX  
Disk storage system  
800mm or more  
Front service area  
2.5  
Installation Environment  
Sufficient consideration of the installation environment should be taken to ensure proper use of the ETERNUS  
DX Disk storage system. Using the ETERNUS DX Disk storage system in an environment that does not satisfy  
the installation environment requirements may cause a failure to occur with the ETERNUS DX Disk storage  
system.  
2.5.1  
Air Conditioning  
It is important to consider the flows of cooling air (intake air) and exhaust air for the installation location. The  
temperature in some ETERNUS DX Disk storage systems may rise when exhaust air is taken in from other  
ETERNUS DX Disk storage systems. In addition, check other factors that might affect the usage environment  
temperature, such as the room size, whether other ETERNUS DX Disk storage systems are installed, and how  
many people are present in the room.  
When installing air conditioning, the ambient temperature should be considered.  
36  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
         
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.6 Outlet/Socket Specifications  
Ambient temperature  
An ETERNUS DX Disk storage system is cooled by taking in air through the front intakes and pushing out  
the exhaust air through the rear of the ETERNUS DX Disk storage system. If the intake air temperature does  
not meet the ambient environment conditions, a temperature error occurs and the power of the ETERNUS  
DX Disk storage system is shut down.  
- Front intake air temperature  
Make sure that the front intake air temperature is between 10 and 40°C.  
- Rear exhaust air temperature  
For example, when the intake air temperature is 40°C, the exhaust air temperature is 50°C or higher.  
The necessary cooling capacity of air conditioning must be checked.  
Check the heat generation amount and the exhaust air amount that are listed in "2.1 Installation  
Specifications" (page 27) to cool the exhaust air from the ETERNUS DX Disk storage system.  
2.5.2  
2.5.3  
Earthquake Resistance  
Take the necessary measures (e.g. secure the rack to the floor or wall) to prevent a rack in which an ETERNUS  
DX Disk storage system is installed from falling down when earthquakes occur.  
Earthquake countermeasures vary depending on the installation location, the floor conditions, and the type  
of rack that is used. Contact your installation contractor for more details regarding earthquake  
countermeasure methods and how work should be conducted.  
Load Bearing Capacity for Floors  
Make sure that the following relationship between the load bearing capacity of the floor and the weight of  
the ETERNUS DX Disk storage system is maintained.  
(Load bearing capacity of the floor) > (ETERNUS DX Disk storage system weight ÷ Installation area that  
includes service areas)  
If the condition above is not satisfied, additional measures are required to ensure sufficient load bearing  
capacity. Contact your installation contractor for details about the necessary measures that must be taken.  
2.6  
Outlet/Socket Specifications  
Power can be supplied to the ETERNUS DX Disk storage system from two power sources because each  
enclosure has two power supply units.  
During normal operation, each of the power sources supplies half of the necessary power.  
When one of the power supply lines fails, all of the necessary power is supplied from only one power source.  
Using the same power supply condition for all of the power supply units is recommended so that different  
power supply conditions (such as whether power distribution units are used or not and input voltage) are not  
used for the ETERNUS DX Disk storage system.  
This section explains the power connection specifications of the ETERNUS DX Disk storage systems.  
37  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.6 Outlet/Socket Specifications  
2.6.1  
Specifications for Optional Power Supply Products  
This section explains the specifications of optional power cords and power related optional products.  
When using power distribution units, the number of outlets that are required to connect the controller  
enclosure and drive enclosures should be taken into consideration.  
In addition, make sure that the plug type of the power distribution unit fits the power socket when using an  
existing power socket. If the plug type does not fit the power socket, replace the socket.  
Power cords  
Power cords supplied with the ETERNUS DX Disk storage system (for the EMEA&I region)  
Table 2.4 Specifications for power cords supplied with the ETERNUS DX Disk storage system (for the  
EMEA&I region)  
Usage  
Plug type  
Socket type  
Cable length  
2.5m  
Remarks  
250V 10A  
IEC60320-C14G  
IEC60320-C13  
Used for connection between the  
ETERNUS DX Disk storage system  
and the socket (IEC60320-C13 ↔  
IEC60320-C14G)  
Power cords supplied with the ETERNUS DX Disk storage system (for regions other than EMEA&I)  
Table 2.5 Specifications for power cords supplied with the ETERNUS DX Disk storage system (for regions  
other than EMEA&I)  
Usage  
Plug type  
Socket type  
Cable length  
4.0m  
Remarks  
250V 15A  
(Normal usage  
<12A)  
NEMA L6-15P  
NEMA L6-15R  
Used for connection between the  
ETERNUS DX Disk storage system  
and the socket  
(IEC60320-C13 ↔  
NEMA L6-15P)  
Optional AC100V and AC200V power cords (for regions other than EMEA&I)  
Optional power cords are used to connect devices with the IEC60320-C13 power socket type. These power  
cords can be used to connect devices with the AC100V and AC200V specifications.  
Table 2.6 Specifications for optional power cords (for regions other than EMEA&I)  
Usage  
Plug type  
Socket type  
Cable length  
3.0m  
Remarks  
250V 10A  
(Normal usage <8A)  
Used for connection between the  
ETERNUS DX Disk storage system  
and the socket  
IEC60320-C14  
IEC60320-C13  
(IEC60320-C13 ↔  
IEC 60320-C14)  
38  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.6 Outlet/Socket Specifications  
Power distribution units (only for regions other than EMEA&I)  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2 enclosures connection)  
Table 2.7 Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2  
enclosures connection)  
Output  
Input  
Remarks  
250V 15A  
Outlet type  
IEC60320-C13  
Plug type  
Socket type  
NEMA L6-15R  
Cable length  
4.0m  
NEMA L6-15P  
(Normal usage  
<12A)  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures connection)  
Table 2.8 Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6  
enclosures connection)  
Output  
Input  
Remarks  
250V 20A  
Outlet type  
IEC60320-C13  
Plug type  
Socket type  
NEMA L6-20R  
Cable length  
4.0m  
NEMA L6-20P  
(Normal usage  
<16A)  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8 enclosures connection)  
Table 2.9 Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8  
enclosures connection)  
Output  
Input  
Remarks  
250V 30A  
Outlet type  
IEC60320-C13  
Plug type  
Socket type  
NEMA L6-30R  
Cable length  
4.0m  
NEMA L6-30P  
(Normal usage  
<24A)  
39  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.6 Outlet/Socket Specifications  
2.6.2  
Required Number of Outlets/Sockets  
The number of power outlets/sockets required to install the ETERNUS DX Disk storage system depends on the  
number of drive enclosures and power distribution units.  
It is recommended that the power cords of the drive enclosures are connected to the power distribution units  
that are installed in the same rack. Secure the necessary number of power outlets within the same rack to  
avoid connecting power cords to power outlets in different racks. It may be necessary to purchase additional  
power distribution units depending on the installation locations of enclosures.  
Without power distribution units  
Two power sockets are required for each enclosure (controller enclosure and drive enclosure).  
With power distribution units  
Two power sockets are required for each power distribution unit. There are three types of power distribution  
units. The size and number of outlets are different for each type.  
Table 2.10 Required number of outlets and sockets to install power distribution units  
Product name  
Number of outlets  
4
Number of sockets  
2
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2  
enclosures connection)  
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6  
enclosures connection)  
12  
16  
2
2
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8  
enclosures connection)  
Power distribution unit (1U)  
Up to two enclosures can be connected to a single power distribution unit (1U).  
Figure 2.6 Power distribution unit (1U)  
Output (4 outlets)  
Input (2 sockets)  
40  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.7 Circuit Protectors  
Power distribution unit (2U)  
- Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures connection)  
Up to six enclosures can be connected.  
- Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8 enclosures connection)  
Up to eight enclosures can be connected.  
Figure 2.7 Power distribution unit (2U)  
Input (2 sockets)  
Output (12 or 16 outlets)  
2.7  
Circuit Protectors  
Protection coordination must be secured between the distribution board circuit protectors and the ETERNUS  
DX Disk storage system or power distribution units to protect the ETERNUS DX Disk storage system by blocking  
the failed circuit immediately when a power supply input error occurs.  
Distribution board circuit protectors must satisfy the following required conditions and breaking  
characteristics.  
Required conditions  
The distribution board circuit protectors must satisfy the required conditions that are listed in Table 2.11.  
Table 2.11 Required conditions for distribution board circuit protectors  
Current capacity  
Power supply  
Connected device  
Regions other  
than EMEA&I  
voltage  
EMEA&I region  
Power distribution unit for DX80 S2/DX90 S2 (AC200-  
240V, 1U, Max 2 enclosures connection)  
AC200 – 240V  
AC200 – 240V  
AC200 – 240V  
15A  
20A  
30A  
15A  
Power distribution unit for DX80 S2/DX90 S2 (AC200-  
240V, 2U, Max 6 enclosures connection)  
Power distribution unit for DX80 S2/DX90 S2 (AC200-  
240V, 2U, Max 8 enclosures connection)  
ETERNUS DX Disk storage system  
(without power distribution units)  
AC100 120V  
AC200 – 240V  
16A  
41  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.7 Circuit Protectors  
Breaking characteristics  
The breaking characteristics (*1) of distribution board circuit protectors must be equivalent to or slower than  
D (IEC898), which is shown in Figure 2.8.  
*1: Relationship between the size of excess current and operation time  
Figure 2.8 Breaking characteristics of distribution board circuit protectors  
180  
120  
60  
40  
20  
10  
6
4
2
1
40  
20  
10  
6
4
2
1
0.6  
0.4  
0.2  
B
C
D
0.1  
~
~
~
0.06  
0.04  
0.02  
0.01  
1
1.5 2  
3
4
5
6 7 8 10 15 20 30 40 50 80 100  
Current (ratio for the current rating)  
42  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.7 Circuit Protectors  
Connection diagrams  
The following diagrams show connections between the power distribution units, the ETERNUS DX Disk storage  
system, and the power sockets of the distribution boards.  
For power distribution unit (1U) connection  
The following diagram shows a power supply connection example when a power distribution unit for DX80  
S2/DX90 S2 (AC200-240V, 1U, Max 2 enclosures connection) is used.  
Figure 2.9 Example of a power supply connection using a power distribution unit (1U)  
ETERNUS DX Disk storage system  
DE #01  
CE  
CP  
CP  
Power distribution unit  
Line 0  
Line 1  
CP  
Distribution  
board  
CP  
Distribution  
board  
To power supply facility  
To power supply facility  
CP: Circuit Protector  
43  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.7 Circuit Protectors  
For power distribution unit (2U) connection  
The following diagram shows a power supply connection example when a power distribution unit for DX80  
S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures connection) or a power distribution unit for DX80 S2/DX90  
S2 (AC200-240V, 2U, Max 8 enclosures connection) is used.  
Figure 2.10 Example of a power supply connection using a power distribution unit (2U)  
ETERNUS DX Disk storage system  
DE #xx  
...  
DE #00  
CE  
CP  
CP  
CP  
CP  
Power distribution unit  
Line 0  
Line 1  
CP  
Distribution  
CP  
Distribution  
board  
board  
To power supply facility  
To power supply facility  
CP: Circuit Protector  
44  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 2 ETERNUS DX Disk Storage System Installation  
2.7 Circuit Protectors  
For direct (no power distribution unit) connection  
The following diagram shows a power supply connection example when no power distribution units are  
used.  
Figure 2.11 Example of a power supply connection without power distribution units  
ETERNUS DX Disk storage system  
DE #02  
CP  
CP  
DE #01  
CE  
Line 0  
Line 1  
CP: Circuit Protector  
Do  
CAUTION  
Only connect the ETERNUS DX Disk storage system to circuit protectors.  
45  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3  
Connections  
This chapter explains connections for the ETERNUS DX Disk storage system.  
3.1  
Host Connections  
FC, iSCSI, FCoE, and SAS are available as host interfaces. The server and the ETERNUS DX Disk storage system  
can be connected directly or via a switch.  
3.1.1  
Host Interfaces  
This section describes each host interface.  
FC (Fibre Channel)  
FC supports two connection topologies: Fibre Channel Arbitrated Loop (FC-AL) and Fabric. Direct connections  
and switch connections to servers are available.  
Two types of host interfaces with a maximum transfer speed of either 16Gbit/s or 8Gbit/s are available.  
When FC switches are used, zoning should be set for the FC switches to ensure the security of data.  
iSCSI  
Direct connections and switch connections to servers are available. Two types of host interfaces with a  
maximum transfer speed of either 10Gbit/s or 1Gbit/s are available.  
In order to maintain iSCSI performance, the iSCSI network should be physically separated from other types of  
networks (such as networks for Internet access and file transfers).  
CHAP  
CHAP authentication can prevent unauthorized access. The following CHAP authentication methods are  
supported:  
- Unidirectional CHAP  
- Bidirectional CHAP  
46  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 3 Connections  
3.1 Host Connections  
Virtual Local Area Network (VLAN tagging)  
The VLAN tagging function is supported. A tag (VLAN ID) can be used for each port.  
When the ETERNUS DX Disk storage system is connected to multiple servers, use a LAN switch that has  
the VLAN function and allocate a separate segment to each server so that security can be maintained.  
Jumbo Frame  
Enabling Jumbo Frame makes data transfer more efficient by increasing the amount of data that can be  
transferred for each Frame.  
Table 3.1 Ethernet frame capacity (Jumbo Frame settings)  
Jumbo Frame settings  
Ethernet frame capacity  
Up to 9000 bytes  
Enabled  
Disabled  
Up to 1500 bytes  
Confirm that the connected device supports Jumbo Frame before enabling Jumbo Frame.  
Server-side CPU load can be reduced by using Jumbo Frame. However, I/O performance may be  
reduced by 10% to 30%.  
Security Architecture for Internet Protocol (IPsec)  
The IPsec function is not supported. Connect the server using a LAN switch that has the IPsec function as  
required.  
Internet Protocol  
IPv4 and IPv6 are supported.  
IPv6 is supported in firmware version V10L35 or later.  
FCoE  
Fabric is supported as a connection topology. The maximum transfer speed is 10Gbit/s. When using an FCoE  
interface, connect the ETERNUS DX Disk storage system to the FCoE switch. Direct connections to servers are  
not supported.  
Perform zoning settings for FCoE switches.  
When an FCoE interface is used for the HBA of the server, use FCoE for the host interface of the ETERNUS  
DX Disk storage system.  
47  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.1 Host Connections  
SAS  
Simple, cost effective, and high performance network storage environment can be configured.  
Direct connections and switch connections to servers are available.  
The maximum transfer speed is 6Gbit/s.  
When SAS switches are used, zoning should be set for the SAS switches to ensure the security of data.  
3.1.2  
Host Connection Path  
This section explains the connection configuration between server Host Bus Adapters (HBAs) and ETERNUS DX  
Disk storage system host interface ports.  
Single path configuration  
A single path configuration connects the ETERNUS DX Disk storage system to a server via a single path.  
The server cannot access an ETERNUS DX Disk storage system when a component (such as a controller, HBA,  
switch, or cable) on the path has a problem. The system must be stopped during the replacement of failed  
components and controller firmware.  
In a single path connection configuration, the path failover and load balancing functions are not supported.  
A multipath connection configuration is recommended to maintain availability when a problem occurs.  
Figure 3.1 Single path connection (direct connection)  
Server  
Server  
HBA  
HBA  
Port Port  
CA  
Port Port  
CA  
CM#0  
CM#1  
ETERNUS DX Disk storage system  
48  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 3 Connections  
3.1 Host Connections  
Figure 3.2 Single path connection (switch connection)  
Server  
Server  
Server  
HBA  
HBA  
HBA  
Switch  
Port Port  
CA  
Port Port  
CA  
CM#0  
CM#1  
ETERNUS DX Disk storage system  
Multipath configuration  
A multipath configuration connects the ETERNUS DX Disk storage system to a server via multiple paths  
(multipath). System reliability is improved due to the path redundancy. For multipath connections, driver  
software to control multipathing is required.  
If a path fails, access can continue by using the path failover function that switches access from the failed path  
to another path. The performance of the system can be improved by using the load balancing function to  
spread the access load over multiple paths.  
Figure 3.3 Multipath connection (direct connection)  
Server  
Server  
HBA  
HBA  
HBA  
HBA  
Port Port Port Port  
CA CA  
Port Port Port Port  
CA CA  
CM#0  
CM#1  
ETERNUS DX Disk storage system  
49  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 3 Connections  
3.1 Host Connections  
Figure 3.4 Multipath connection (switch connection)  
Server  
Server  
Server  
HBA  
HBA  
HBA  
HBA  
HBA  
HBA  
Switch  
Switch  
Port Port  
CA  
Port Port  
CA  
CM#0  
CM#1  
ETERNUS DX Disk storage system  
When configuring multipathing for reliability, make sure to configure a redundant connection for the  
controllers of the ETERNUS DX Disk storage system. Configure paths to connect to different controllers  
(CM#0 and CM#1). Combinations of host interface numbers (CA#0 and CA#1) in controllers do not need  
to be taken into consideration.  
Paths from a single server should be separately connected to a different host interface in case of host  
interface failure.  
Cluster configuration  
When a server is duplicated in a cluster configuration and the ETERNUS DX Disk storage system is shared by  
multiple servers, software to control the cluster configuration is required.  
50  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.1 Host Connections  
Configurations that satisfy the system requirements  
System requirements should be taken into consideration for a connection configuration between the HBAs on  
the server and the host interface ports on the ETERNUS DX Disk storage system.  
The following figure shows a connection configuration for availability:  
Figure 3.5 Connection that satisfies the system requirements (for availability)  
Server  
Server  
HBA  
HBA  
HBA  
HBA  
Port Port  
CA#0  
Port Port  
CA#0  
CM#0  
CM#1  
ETERNUS DX Disk storage system  
The following figure shows a connection configuration for enhanced performance:  
Figure 3.6 Connection that satisfies the system requirements (for enhanced performance)  
Server  
Server  
HBA  
HBA  
HBA  
HBA  
Port Port Port Port  
CA#0 CA#1  
Port Port Port Port  
CA#0 CA#1  
CM#0  
CM#1  
ETERNUS DX Disk storage system  
When the ETERNUS DX Disk storage system is accessed from both of the servers, performance can be secured  
by connecting to the ETERNUS DX Disk storage system using one host interface port on each of the four host  
interfaces.  
51  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 3 Connections  
3.2 Remote Connections  
3.2  
Remote Connections  
An FC or iSCSI interface is available for a remote connection.  
For remote connections, different types of interfaces (FC, iSCSI 10Gbit/s, iSCSI 1Gbit/s) cannot exist together  
on a REC path (connection between a local ETERNUS DX Disk storage system and a remote ETERNUS DX Disk  
storage system).  
When different types of remote interfaces exist in the same ETERNUS DX Disk storage system, make sure to  
use the same type of interface for each REC path.  
For example, the following configuration is not supported because different types of interfaces (FC/iSCSI)  
exist together on a REC path.  
Figure 3.7 Example of non-supported connection configuration (when multiple types of remote interfaces  
are installed in the same ETERNUS DX Disk storage system)  
ETERNUS DX  
Disk storage  
system  
ETERNUS DX  
Disk storage  
system  
FC-RA  
FC-RA  
REC path  
iSCSI-RA  
iSCSI-RA  
The following configuration is supported because the same type of interface is used for each REC path.  
Figure 3.8 Example of supported connection configuration (when multiple types of remote interfaces are  
installed in the same ETERNUS DX Disk storage system)  
ETERNUS DX  
Disk storage  
system  
ETERNUS DX  
Disk storage  
system  
ETERNUS DX  
Disk storage  
system  
FC-RA  
FC-RA  
FC-RA  
iSCSI-RA  
iSCSI-RA  
iSCSI-RA  
iSCSI-RA  
REC path  
REC path  
FC-RA  
52  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 3 Connections  
3.2 Remote Connections  
3.2.1  
Remote Interfaces  
This section describes each remote interface.  
FC (Fibre Channel)  
Data is transferred between multiple ETERNUS DX Disk storage systems by using host interfaces. The ETERNUS  
DX Disk storage system can be connected to the destination storage system directly or via switch. A digital  
service unit is required for a remote connection that is using a line. Two types of host interfaces with a  
maximum transfer speed of either 16Gbit/s or 8Gbit/s are available.  
Figure 3.9 FC connection for remote copy (redundant path)  
ETERNUS DX Disk storage system  
ETERNUS DX Disk storage system  
FC switch  
FC switch  
FC-RA  
Copy  
source  
FC-RA  
Copy  
destination  
SAN (FC)  
FC-RA  
FC-RA  
FC switch  
FC switch  
Figure 3.10 FC connection for remote copy (using lines)  
ETERNUS DX Disk storage system  
ETERNUS DX Disk storage system  
Copy  
destination  
Copy  
source  
WAN (IP line)  
FC-RA  
FC-RA  
Digital service unit  
Digital service unit  
iSCSI  
Data is transferred between multiple ETERNUS DX Disk storage systems by using host interfaces. Direct  
connection to a WAN is possible.  
Two types of host interfaces with a maximum transfer speed of either 10Gbit/s or 1Gbit/s are available.  
Figure 3.11 iSCSI connection for remote copy (using lines)  
ETERNUS DX Disk storage system  
ETERNUS DX Disk storage system  
Copy  
destination  
Copy  
source  
WAN (IP line)  
iSCSI-RA  
iSCSI-RA  
Switch  
Switch  
53  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 3 Connections  
3.2 Remote Connections  
The IPsec function is not supported for iSCSI interfaces. To use the IPsec function when performing a remote  
copy with the ETERNUS DX90 S2, the ETERNUS DX410 S2/DX440 S2, or the ETERNUS DX8100 S2/DX8700 S2,  
use a LAN switch that has the IPsec function.  
3.2.2  
Connectable Models  
Remote copy is available for the ETERNUS DX90 S2. The ETERNUS DX90 S2 can be connected to not only the  
same model, it can also be connected to the ETERNUS DX410 S2/DX440 S2, the ETERNUS DX8100 S2/DX8700  
S2, and older ETERNUS Disk storage system models. The following table shows the models that can be  
connected and the interfaces that are available.  
Table 3.2 Connectable models and available remote interfaces  
Remote interface  
Connectable model (*1)  
FC  
FC  
iSCSI 10Gbit/s  
iSCSI  
16Gbit/s  
8Gbit/s  
1Gbit/s  
ETERNUS DX90 S2  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
Available  
ETERNUS DX410 S2/DX440 S2  
ETERNUS DX8100 S2/DX8700 S2  
Available  
(*2)  
ETERNUS DX90  
ETERNUS DX410/DX440  
ETERNUS DX8100/DX8400/DX8700  
Available  
(*2)  
Available  
Available  
ETERNUS4000 models 400, 600  
ETERNUS8000 models 800, 1200, 2200  
Available  
(*2)  
ETERNUS4000 models 300, 500  
ETERNUS8000 models 700, 900, 1100, 2100  
Available  
(*3)  
Available  
(*4)  
Available  
(*5) (*6)  
Available  
(*6)  
ETERNUS6000  
*1: Firmware upgrade may be required to connect to the ETERNUS DX90 S2. For information about firmware versions,  
contact your sales representative.  
*2: The transfer speed is 8Gbit/s or 4Gbit/s.  
*3: The transfer speed is 4Gbit/s.  
*4: The transfer speed is 4Gbit/s or 2Gbit/s.  
*5: Connections are available via switches. Direct connections are not supported.  
*6: The transfer speed is FC 2Gbit/s. Remote connections are available only when data is migrated.  
Stack mode or Through mode can be used as the transfer mode.  
54  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 3 Connections  
3.3 LAN Connection  
3.3  
LAN Connection  
The ETERNUS DX Disk storage system requires a LAN connection for operation management.  
In addition, information such as ETERNUS DX Disk storage system failures is notified to the remote support  
center.  
Make sure to connect each controller to the LAN for operation management.  
Figure 3.12 Example of a LAN connection  
Administration terminal  
SNMP  
manager  
- Operation  
management/setting  
- Wake On LAN  
NTP server  
Mail server  
Authentication  
server  
Syslog server  
Remote support  
center  
ETERNUS DX  
Disk storage system  
When using ETERNUS Web GUI to manage operations, prepare a Web browser in the administration terminal.  
The following table shows the supported Web browsers.  
Table 3.3 ETERNUS Web GUI operating environment  
Software  
Guaranteed operating environment  
Web browser  
Microsoft Internet Explorer 7.0, 8.0, 9.0, 10.0 (desktop version)  
Mozilla Firefox 3.6.x, ESR 10.0.x, ESR 17.0.x  
When using ETERNUS Web GUI to connect the ETERNUS DX Disk storage system, the default port number is 80  
for http.  
The LAN port for operation management on the ETERNUS DX Disk storage system uses Ethernet (1000Base-T /  
100Base-TX / 10Base-T) for the interface. IPv4 and IPv6 are supported as Internet Protocols.  
55  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 3 Connections  
3.4 Power Supply Connection  
The following items are supported in firmware version V10L30 or later:  
Internet Explorer 9.0  
Firefox ESR 10.0.x  
IPv6  
The following item is supported in firmware version V10L40 or later:  
Internet Explorer 10.0 (desktop version)  
The following item is supported in firmware version V10L45 or later:  
Firefox ESR 17.0.x  
LAN for operation management  
In an ETERNUS DX Disk storage system, the system administrator logs on to the ETERNUS DX Disk storage  
system via a LAN to set the RAID configuration, manage operations, and perform maintenance. The computer  
for operation management that is used for accessing the ETERNUS DX Disk storage system via ETERNUS Web  
GUI or ETERNUS CLI is called an administration terminal.  
In addition, the functions that are provided by the management/monitoring server on the LAN can be used.  
These functions include SNMP (device monitoring), SMTP (e-mail sending), NTP (time correction), syslog  
(event notification and audit log sending), RADIUS (user authentication), and KMIP(key management).  
LAN for remote support  
Various failures that occur in the ETERNUS DX Disk storage system are notified to the remote support center.  
Remote support connection can be separated from the LAN for operation management.  
3.4  
Power Supply Connection  
Connect the power cords (AC cables) of the ETERNUS DX Disk storage system to the power sockets, the UPS  
sockets, or the power control unit sockets.  
Refer to "2.6 Outlet/Socket Specifications" (page 37) for details about the types and the number of power  
outlets/sockets.  
Two power supply units (PSU#0 and PSU#1) are installed in each enclosure. Make sure that power cords are  
connected to both of the power supply units.  
56  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.4 Power Supply Connection  
3.4.1  
Input Power Supply Lines  
Multiple power supply facilities in the building or UPS units are recommended for power supply redundancy.  
When the ETERNUS DX Disk storage system power supply is redundantly configured, business can continue  
even if one of the power lines fails.  
Alternatively, optimal system design (including the server) may instead lead to the ETERNUS DX Disk storage  
system being configured with only a single power supply facility or UPS unit. Which configuration is selected  
will depend on system availability requirement considerations.  
Figure 3.13 Dual-line power supply when connecting to power sockets  
ETERNUS DX  
Power distribution unit  
Disk storage system  
Line 1  
PSU  
PSU  
Line 0  
Figure 3.14 Dual-line power supply when connecting to UPS units  
ETERNUS DX  
Power distribution unit  
Disk storage system  
UPS  
PSU  
Line 1  
UPS  
PSU  
Line 0  
Figure 3.15 Single-line power supply when connecting to power sockets  
ETERNUS DX  
Disk storage system  
Power distribution unit  
PSU  
Line 0  
PSU  
57  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 3 Connections  
3.4 Power Supply Connection  
Figure 3.16 Single-line power supply when connecting to a UPS unit  
ETERNUS DX  
Disk storage system  
Power distribution unit  
UPS  
PSU  
Line 0  
PSU  
Figure 3.17 Single-line power supply when connecting to a power socket and a UPS unit  
ETERNUS DX  
Power distribution unit  
Disk storage system  
PSU  
Line 0  
UPS  
PSU  
When the power distribution units are separately connected to line 0 (PSU#0) and line 1 (PSU#1), the  
availability of the power supply facilities is improved.  
ETERNUS DX  
Disk storage system  
Power distribution unit  
Power distribution unit  
DE #0x  
...  
DE #01  
CE  
Line 0  
Line 1  
58  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 3 Connections  
3.4 Power Supply Connection  
3.4.2  
UPS Connection  
It is recommended that an Uninterruptible Power Supply System (UPS) be used as the power supply source for  
the ETERNUS DX Disk storage system to cope with power outages and momentary voltage drops in the normal  
power supply.  
Note that when connecting an ETERNUS DX Disk storage system to a UPS with one power supply line, the total  
value of the power requirements for all the enclosures must not exceed the UPS output capacity.  
When one of the power supply lines fails for redundantly configured UPS units with two power supply lines, all  
of the power for the ETERNUS DX Disk storage system must be supplied from the other line. Select a UPS that  
can supply sufficient power so that the total value of the power requirements does not exceed the UPS output  
capacity in case only one power supply line is available.  
For details about the necessary UPS output capacity, refer to the specifications of the UPS that is used.  
A UPS must satisfy the following conditions:  
Rating capacity  
Secure a sufficient rating capacity for the total value of the maximum power requirements for the  
enclosures that are to be installed.  
For the maximum power requirements of each enclosure, refer to "2.1 Installation Specifications" (page  
27).  
Supply time  
The total time for the server to shut down and for the ETERNUS DX Disk storage system to power off  
(maximum of six minutes) must be taken into consideration for the power supply time of the battery.  
Switching time during power failure  
The normal power supply must be switched to UPS output within 11ms after a power failure occurs.  
Socket type  
If the power plug type and the socket type of the UPS do not match, it is necessary to equip the UPS (AC  
output) with an appropriate type of socket. Request a qualified electrician to perform the necessary work to  
make terminal block connections available.  
Power supply configuration  
If a UPS is used, make sure that it supplies power to all the enclosures.  
Configurations where the controller enclosure is powered by the UPS while the drive enclosures are  
powered directly from AC are not supported.  
59  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.5 Power Synchronized Connections  
3.5  
Power Synchronized Connections  
This section describes connections to automatically control powering the ETERNUS DX Disk storage system on  
and off with a server.  
Do  
WARNING  
In order to control powering the ETERNUS DX Disk storage system on and off  
with servers, the power control of the ETERNUS DX Disk storage system must  
be linked with all of the connected servers. If some of the servers are not  
linked, data errors may occur in these servers when the ETERNUS DX Disk  
storage system is turned off by using power control from the other linked  
servers.  
Power synchronized unit  
A power synchronized unit enables the ETERNUS DX Disk storage system to be powered on and off with a  
server. The power synchronized unit detects changes in the AC power output of a UPS unit that is connected to  
a server (server UPS unit) and automatically turns on and off the ETERNUS DX Disk storage system. In addition  
to server UPS units, units that control the AC socket power output can also be connected. When three or more  
servers are connected, power can be synchronized by adding an AC sensor unit.  
The power synchronized unit detects the AC power output of the target devices for power synchronization and  
commands the ETERNUS DX Disk storage system to synchronize the power with the target devices.  
When the power synchronized unit detects the AC power output of any server UPS unit, the power  
synchronized unit commands the ETERNUS DX Disk storage system to turn on.  
When the power synchronized unit does not detect AC power output in any of the server UPS units, the power  
synchronized unit commands the ETERNUS DX Disk storage system to turn off.  
The server UPS unit must have a function in the management software that controls the AC power output  
according to when the server powers on and off. The server UPS unit must have one unused outlet to connect  
to the power synchronized unit.  
60  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.5 Power Synchronized Connections  
When connecting one or two servers  
Figure 3.18 Power control using a power synchronized unit (when connecting one or two servers)  
UPS setting  
Turns on: 1  
Turns off: 2  
Turns on: 2  
Turns off: 1  
Server  
UPS  
management  
software  
UPS  
Power synchronized unit  
PWC  
4
ETERNUS DX  
Disk storage system  
RS232C cable  
PWC  
An instruction is  
issued to turn on/off  
the ETERNUS DX  
Disk storage  
3
system when AC  
output/no AC output  
is detected.  
Powering on sequence  
1
2
Power on of all the server UPS units  
Server startup  
The server OS startup is suspended until the ETERNUS DX Disk storage system startup is complete  
(*1).  
3
4
Issuance of command to turn on the ETERNUS DX Disk storage system from the power synchronized  
unit  
ETERNUS DX Disk storage system startup  
*1: The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is  
complete.  
61  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.5 Power Synchronized Connections  
Powering off sequence  
1
2
3
Shutdown of all the servers  
Shutdown of all the server UPS units  
Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized  
unit  
4
ETERNUS DX Disk storage system shutdown  
When connecting three or more servers  
Figure 3.19 Power control using a power synchronized unit (when connecting three or more servers)  
Turns on: 1  
Turns off: 2  
Turns on: 2  
Turns off: 1  
Server#1  
UPS unit for  
Server#1  
Server#3  
UPS unit for  
Server#3  
AC sensor  
unit#1  
Server#0  
UPS unit for  
Server#0  
Server#2  
UPS unit for  
Server#2  
AC sensor  
unit#0  
Power synchronized  
unit#0  
PWC PWC  
ETERNUS DX  
4
Disk storage system  
PWC  
3
ETERNUS DX  
4
Disk storage system  
PWC  
62  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 3 Connections  
3.5 Power Synchronized Connections  
Powering on sequence  
1
2
Power on of all the server UPS units  
Server startup  
The server OS startup is suspended until the ETERNUS DX Disk storage system startup is complete  
(*1).  
3
4
Issuance of command to turn on the ETERNUS DX Disk storage system from the power synchronized  
unit  
ETERNUS DX Disk storage system startup  
*1: The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is  
complete.  
Powering off sequence  
1
2
3
Shutdown of all the servers  
Shutdown of all the server UPS units  
Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized  
unit  
4
ETERNUS DX Disk storage system shutdown  
Refer to the manual that is provided with a power synchronized unit for details about connection  
configurations with power synchronized units and required settings.  
63  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Chapter 4  
Rack and Optional Product Installation  
This chapter explains the requirements for installation of racks and the optional products for an ETERNUS DX  
Disk storage system.  
4.1  
Rack Installation Requirements  
This section explains the requirements for installing the ETERNUS DX Disk storage system in a 19-inch rack.  
4.1.1  
Placement in the Rack  
Note the following when installing the ETERNUS DX Disk storage system in the rack.  
The center of gravity must be taken into consideration to prevent a rack from toppling over. Enclosures  
should generally be installed from bottom to top to lower the center of gravity and to ensure the safe use  
of racks.  
Enclosures are installed in the following order (from bottom to top).  
Table 4.1 Enclosure installation order  
Order  
Enclosure  
Power distribution unit (PDU)  
Controller enclosure (CE)  
Drive enclosure (DE)  
Size (height)  
1
2
3
1U/2U  
2U  
2U  
Install drive enclosures in order of DE-IDs (drive enclosure numbers)  
.
When determining the rack-mounting layout, consider the placement of each enclosure and the power  
distribution unit in the rack and the length of each cable. For example, if the ETERNUS DX Disk storage  
system is installed at the top of a 1800mm rack, the surplus length of the power cord at the bottom of a  
rack should be about 2m.  
If the storage system is installed at the bottom of a rack, a space for the surplus of cables may not be  
available in some racks, preventing the storage system from being pulled out when maintenance work is  
required.  
In this case, secure a space of 1U or more at the bottom when installing the storage system.  
If drive enclosures are to be added in the future, securing sufficient space for power distribution units in  
the bottom of the rack is recommended.  
64  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
         
Chapter 4 Rack and Optional Product Installation  
4.1 Rack Installation Requirements  
4.1.2  
Cable Connection  
Power supply connection  
It is recommended that the power cords (AC cables) of the enclosures are connected to the power distribution  
units that are installed in the same rack. Secure the necessary number of power outlets within the same rack  
to avoid connecting power cords to power outlets in different racks.  
It may be necessary to purchase additional power distribution units depending on the installation locations of  
enclosures.  
The length of the AC output cable that is supplied with the power distribution unit is 3m.  
Figure 4.1 AC cable connection  
Rack-1  
Rack-2  
DE  
DE  
DE  
DE  
DE  
DE  
DE  
DE  
CE  
PDU  
PDU  
An AC cable should not be  
connected to a power  
: AC cable  
distribution unit that is installed  
in a different rack.  
65  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 4 Rack and Optional Product Installation  
4.1 Rack Installation Requirements  
Connections between enclosures  
If enclosures are installed in multiple racks or are installed with space in the same rack, the QSFP cables  
(0.75m) that are included with the ETERNUS DX Disk storage system may be too short for connections  
between enclosures.  
In this case, use the Extension cable between enclosures. The length of the Extension cable between  
enclosures that is provided is 3m or 6m. Enclosures in different racks can be installed within this length.  
Figure 4.2 QSFP cable connection (single-controller type)  
Rack-1  
Rack-2  
DE  
DE  
DE  
DE  
DE  
DE  
DE  
DE  
CE  
PDU  
PDU  
: Cable supplied as standard  
: Extension cable between enclosures  
66  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 4 Rack and Optional Product Installation  
4.2 Installable Racks  
Figure 4.3 QSFP cable connection (dual-controller type)  
Rack-1  
Rack-2  
DE  
DE  
DE  
DE  
DE  
DE  
CE  
ACS  
DE  
DE  
ACS  
: Cable supplied as standard  
: Extension cable between enclosures  
4.2  
Installable Racks  
This section explains the racks in which the ETERNUS DX Disk storage system can be installed.  
4.2.1  
Fujitsu Racks  
The ETERNUS DX Disk storage system can be installed in a Fujitsu 19-inch rack. For information about whether  
the ETERNUS DX Disk storage system can be installed in an EOLed rack or not, contact your sales  
representative.  
67  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
     
Chapter 4 Rack and Optional Product Installation  
4.2 Installable Racks  
4.2.2  
Non-Fujitsu Racks  
ETERNUS DX Disk storage systems are developed and their operation is guaranteed on the assumption that  
they are installed in Fujitsu 19-inch racks. Since the ETERNUS DX Disk storage system cannot be tested (for  
cooling and strength) in non-Fujitsu 19-inch racks, the operations of ETERNUS DX Disk storage systems cannot  
be guaranteed. Any problem that may occur by installing the ETERNUS DX Disk storage system in non-Fujitsu  
racks is not covered by the warranty.  
If the ETERNUS DX Disk storage system needs to be installed in a non-Fujitsu rack, the following conditions  
must be satisfied.  
Rack specifications  
Use the rack mount kit supplied with the product to install the ETERNUS DX Disk storage system in the rack.  
The rack specifications must satisfy the conditions listed below. For rack specifications, refer to the manual  
that is supplied with the rack that is used.  
Pitch for mounting holes  
EIA Standard Universal pitch  
Size for mounting holes  
The size must be 9mm or more.  
Load bearing capacity  
The load bearing capacity must be equal to or larger than the total weight of the ETERNUS DX Disk storage  
system.  
Unit installation area  
The dimensions of the area shown in Figure 4.4 must match the conditions described in Table 4.2.  
Figure 4.4 Unit installation area  
(1)  
(2)  
(3)  
Rack rails  
ETERNUS DX  
Disk storage system  
(4)  
Rack front door  
Rack pillars  
Rack rear door  
68  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
Table 4.2 Specifications for the unit installation area  
Specification  
Condition  
40mm or more  
(1)  
Rack front space  
(Space between the fixed part of the ETERNUS DX Disk storage system on  
the front side and the front of the rack)  
(2)  
(3)  
Mount bracket length  
(Size between each end of the front and rear rack pillars)  
685mm to 775mm  
830mm or more  
Rack space  
(Space between the fixed part of the ETERNUS DX Disk storage system on  
the front side and the rear of the rack)  
(4)  
Rack mount kit installation area  
482mm or more  
(recommended)  
Placement conditions  
When determining service areas, refer to the installation document of the rack to be used.  
Install air conditioning in order to ensure that the interior temperature of the rack satisfies the temperature  
4.3  
Standard Installation Rules Before Shipment  
(Only for Regions Other than EMEA&I)  
This section explains the rules for combining the following optional products and standard installation rules  
that apply before shipment from the factory.  
Host interfaces  
Drive enclosures  
Drives  
69  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
4.3.1  
Host Interfaces  
This section explains the installation rules for host interfaces.  
The following types of host interfaces (CA) are available:  
FC 16Gbit/s (dual port type)  
FC 8Gbit/s (dual port type)  
iSCSI 10Gbit/s (dual port type)  
iSCSI 10Gbit/s (dual port type, without SFP+ modules)  
iSCSI 1Gbit/s (dual port type)  
FCoE 10Gbit/s (dual port type)  
FCoE 10Gbit/s (dual port type, without SFP+ modules)  
SAS 6Gbit/s (dual port type)  
Different types of interfaces can be mixed for the same ETERNUS DX Disk storage system.  
Install the host interfaces for CA#0 first, and then CA#1 according to Table 4.3.  
For a dual-controller type, the configuration is the same for Controller 0 (CM#0) and Controller 1 (CM#1).  
The following table shows the priority order of host interface installation.  
Table 4.3 Priority order of host interface installation  
Priority order  
Type  
Interface  
1
2
3
4
5
6
7
8
FC 16Gbit/s  
FC 8Gbit/s  
iSCSI 10Gbit/s  
iSCSI 10Gbit/s (without SFP+ modules)  
iSCSI 1Gbit/s  
Host interface (2port)  
FCoE 10Gbit/s  
FCoE 10Gbit/s (without SFP+ modules)  
SAS 6Gbit/s  
For a single-controller type  
Figure 4.5 Installation diagram for a host interface (single-controller type)  
Port  
#0  
Port  
#1  
Port  
#0  
Port  
#1  
CA#0  
CA#1  
Expansion  
Controller 0 (CM#0)  
70  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
For a dual-controller type  
Figure 4.6 Installation diagram for host interfaces (dual-controller type)  
Port  
#0  
Port  
#1  
Port  
#0  
Port  
#1  
Port  
#0  
Port  
#1  
Port  
#0  
Port  
#1  
CA#0  
CA#1  
CA#0  
CA#1  
Expansion  
Expansion  
Controller 0 (CM#0)  
Controller 1 (CM#1)  
4.3.2  
Drive Enclosures  
This section explains the installation rules for drive enclosures. 2.5" type and 3.5" type drive enclosures can be  
installed together in the ETERNUS DX Disk storage system.  
The priority order of drive enclosure installation varies depending on the controller enclosure type.  
2.5" type controller enclosure  
Table 4.4 Priority order of drive enclosure installation (for 2.5" type controller enclosure)  
Priority order  
Type  
1
2
Drive enclosure (2.5inch)  
Drive enclosure (3.5inch)  
3.5" type controller enclosure  
Table 4.5 Priority order of drive enclosure installation (for 3.5" type controller enclosure)  
Priority order  
Type  
1
2
Drive enclosure (3.5inch)  
Drive enclosure (2.5inch)  
For the ETERNUS DX80 S2/DX90 S2, up to nine drive enclosures can be installed.  
When only 2.5" type enclosures are used for the ETERNUS DX80 S2, up to four drive enclosures can be  
installed.  
DE-IDs are automatically assigned for a drive enclosure based on the installation order.  
71  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
       
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
4.3.3  
Drives  
This section explains the installation rules for drives.  
2.5" drives  
The following table shows the priority order of 2.5" drive installation.  
Table 4.6 Priority order of 2.5" drive installation  
Priority order  
Type  
Drive capacity/quantity  
100GB (SLC) x 2  
RAID level  
1
2
RAID1  
100GB (SLC) x 6  
100GB (SLC) x 4  
100GB (SLC) x 1  
200GB (SLC) x 2  
200GB (SLC) x 6  
200GB (SLC) x 4  
200GB (SLC) x 1  
400GB (SLC) x 2  
400GB (SLC) x 6  
400GB (SLC) x 4  
400GB (SLC) x 1  
400GB (MLC) x 6  
400GB (MLC) x 4  
400GB (MLC) x 1  
800GB (MLC) x 2  
800GB (MLC) x 6  
800GB (MLC) x 4  
800GB (MLC) x 1  
RAID1+0  
RAID5  
3
4
Hot spare  
RAID1  
5
6
RAID1+0  
RAID5  
7
8
Hot spare  
RAID1  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
SSD (2.5inch)  
RAID1+0  
RAID5  
Hot spare  
RAID1+0  
RAID5  
Hot spare  
RAID1  
RAID1+0  
RAID5  
Hot spare  
72  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
Priority order  
Type  
Drive capacity/quantity  
300GB/15krpm x 2  
300GB/15krpm x 6  
300GB/15krpm x 6  
300GB/15krpm x 6  
300GB/15krpm x 1  
300GB/10krpm x 2  
300GB/10krpm x 6  
300GB/10krpm x 6  
300GB/10krpm x 6  
300GB/10krpm x 1  
450GB/10krpm x 2  
450GB/10krpm x 6  
450GB/10krpm x 6  
450GB/10krpm x 6  
450GB/10krpm x 1  
600GB/10krpm x 2  
600GB/10krpm x 6  
600GB/10krpm x 6  
600GB/10krpm x 6  
600GB/10krpm x 1  
900GB/10krpm x 2  
900GB/10krpm x 6  
900GB/10krpm x 6  
900GB/10krpm x 6  
900GB/10krpm x 1  
RAID level  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
Disk Drive (2.5inch)  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
Disk Drive (2.5inch)  
RAID1+0  
RAID5  
RAID6  
Hot spare  
73  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
Priority order  
Type  
Drive capacity/quantity  
300GB/10krpm x 2  
300GB/10krpm x 6  
300GB/10krpm x 6  
300GB/10krpm x 6  
300GB/10krpm x 1  
450GB/10krpm x 2  
450GB/10krpm x 6  
450GB/10krpm x 6  
450GB/10krpm x 6  
450GB/10krpm x 1  
600GB/10krpm x 2  
600GB/10krpm x 6  
600GB/10krpm x 6  
600GB/10krpm x 6  
600GB/10krpm x 1  
900GB/10krpm x 2  
900GB/10krpm x 6  
900GB/10krpm x 6  
900GB/10krpm x 6  
900GB/10krpm x 1  
1TB/7.2krpm x 2  
RAID level  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
Self Encrypting Disk Drive  
(2.5inch)  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
1TB/7.2krpm x 6  
RAID1+0  
RAID5  
Disk Drive (2.5inch)  
1TB/7.2krpm x 6  
1TB/7.2krpm x 6  
RAID6  
1TB/7.2krpm x 1  
Hot spare  
Up to twenty-four 2.5" drives can be installed in a controller enclosure or a drive enclosure (2.5" type). Drives  
with different types can be installed in a single enclosure.  
Install drives in the slots of a controller enclosure from Slot#0 to Slot#23 in ascending order according to the  
installation order in Table 4.6. Then, install drives in the slots of a drive enclosure from Slot#0 to Slot#23 in  
ascending order.  
Figure 4.7 Installation diagram for 2.5" drives  
74  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
3.5" drives  
The following table shows the priority order of 3.5" drive installation.  
Table 4.7 Priority order of 3.5" drive installation  
Priority order  
Type  
Drive capacity/quantity  
100GB (SLC) x 2  
RAID level  
1
RAID1  
2
100GB (SLC) x 6  
100GB (SLC)x 4  
RAID1+0  
RAID5  
3
4
100GB (SLC) x 1  
200GB (SLC) x 2  
200GB (SLC) x 6  
200GB (SLC) x 4  
200GB (SLC) x 1  
400GB (SLC) x 2  
400GB (SLC) x 6  
400GB (SLC) x 4  
400GB (SLC) x 1  
400GB (MLC) x 6  
400GB (MLC) x 4  
400GB (MLC) x 1  
800GB (MLC) x 2  
800GB (MLC) x 6  
800GB (MLC) x 4  
800GB (MLC) x 1  
300GB/15krpm x 2  
300GB/15krpm x 6  
300GB/15krpm x 6  
300GB/15krpm x 6  
300GB/15krpm x 1  
450GB/15krpm x 2  
450GB/15krpm x 6  
450GB/15krpm x 6  
450GB/15krpm x 6  
450GB/15krpm x 1  
Hot spare  
RAID1  
5
6
RAID1+0  
RAID5  
7
8
Hot spare  
RAID1  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
SSD (3.5inch)  
RAID1+0  
RAID5  
Hot spare  
RAID1+0  
RAID5  
Hot spare  
RAID1  
RAID1+0  
RAID5  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
Disk Drive (3.5inch)  
RAID1+0  
RAID5  
RAID6  
Hot spare  
75  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
Priority order  
Type  
Drive capacity/quantity  
600GB/15krpm x 2  
600GB/15krpm x 6  
600GB/15krpm x 6  
600GB/15krpm x 6  
600GB/15krpm x 1  
1TB/7.2krpm x 2  
1TB/7.2krpm x 6  
1TB/7.2krpm x 6  
1TB/7.2krpm x 6  
1TB/7.2krpm x 1  
2TB/7.2krpm x 2  
2TB/7.2krpm x 6  
2TB/7.2krpm x 6  
2TB/7.2krpm x 6  
2TB/7.2krpm x 1  
3TB/7.2krpm x 2  
3TB/7.2krpm x 6  
3TB/7.2krpm x 6  
3TB/7.2krpm x 6  
3TB/7.2krpm x 1  
4TB/7.2krpm x 2  
4TB/7.2krpm x 6  
4TB/7.2krpm x 6  
4TB/7.2krpm x 6  
4TB/7.2krpm x 1  
RAID level  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
Disk Drive (3.5inch)  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
RAID1  
RAID1+0  
RAID5  
RAID6  
Hot spare  
Up to twelve 3.5" drives can be installed in a controller enclosure or a drive enclosure (3.5" type).  
Drives with different types can be installed in a single enclosure.  
Install drives in the slots of a controller enclosure from Slot#0 to Slot#11 in ascending order according to the  
installation order in Table 4.7. Then, install drives in the slots of a drive enclosure from Slot#0 to Slot#11 in  
ascending order.  
Figure 4.8 Installation diagram for 3.5" drives  
Slot#11  
Slot#8  
Slot#4  
Slot#0  
Slot#9  
Slot#5  
Slot#1  
Slot#10  
Slot#6  
Slot#2  
Slot#7  
Slot#3  
76  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
4.3.4  
Drive Installation Examples  
This section provides examples of drive installation at shipment.  
2.5" type controller enclosure  
For a 2.5" type controller enclosure, 2.5" type drive enclosures are installed before 3.5" type drive enclosures.  
2.5" drives are installed in the 2.5" type controller enclosure and drive enclosures, and 3.5" drives are installed  
in the 3.5" type drive enclosures.  
Figure 4.9 Drive installation example at shipment (2.5" type controller enclosure)  
DE#2  
F
F
F
F
H3  
F
F
DE#1  
H
1
H
1
H
2
C
C
D
D
D
D
D
D
E
E
E
E
E
E
CE#0  
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
Installation order  
A: 2.5" SSD (100GB, RAID5) x 3  
B: 2.5" SSD (200GB, RAID1+0) x 2  
H1: 2.5" SSD (200GB, hot spare) x 2  
C: 2.5" SAS (450GB, RAID1)  
D: 2.5" SAS (450GB, RAID6)  
E: 2.5" SAS (600GB, RAID5)  
H2: 2.5" SAS (600GB, hot spare)  
F: 3.5" Nearline SAS (2TB, RAID5)  
H3: 3.5" Nearline SAS (2TB, hot spare)  
77  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
   
Chapter 4 Rack and Optional Product Installation  
4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)  
3.5" type controller enclosure  
For a 3.5" type controller enclosure, 3.5" type drive enclosures are installed before 2.5" type drive enclosures.  
3.5" drives are installed in the 3.5" type controller enclosure and drive enclosures, and 2.5" drives are installed  
in the 2.5" type drive enclosures.  
Figure 4.10 Drive installation example at shipment (3.5" type controller enclosure)  
DE#2  
H
2
H
3
C
C
C
C
D
D
DE#1  
B
B
B
H1  
B
B
B
CE#0  
A
A
A
A
A
A
A
A
A
A
A
A
Installation order  
A: 3.5" Nearline SAS (1TB, RAID1+0) x 2  
B: 3.5" Nearline SAS (2TB, RAID5)  
H1: 3.5" Nearline SAS (2TB, hot spare)  
C: 2.5" SSD (200GB, RAID5)  
H2: 2.5" SSD (200GB, hot spare)  
D: 2.5" SAS (300GB, RAID1)  
H3: 2.5" SAS (300GB, hot spare)  
78  
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-  
Copyright 2013 FUJITSU LIMITED  
P3AM-4822-12ENZ0  
 
ETERNUS DX80 S2/DX90 S2 Disk storage system  
User's Guide -Site Planning-  
P3AM-4822-12ENZ0  
Date of issuance: June 2013  
Issuance responsibility: FUJITSU LIMITED  
The content of this manual is subject to change without notice.  
This manual was prepared with the utmost attention to detail.  
However, Fujitsu shall assume no responsibility for any operational problems as the result of  
errors, omissions, or the use of information in this manual.  
Fujitsu assumes no liability for damages to third party copyrights or other rights arising from  
the use of any information in this manual.  
The content of this manual may not be reproduced or distributed in part or in its entirety  
without prior permission from Fujitsu.  

Hobart CG831 User Manual
Event electronic PS6 User Manual
Electrolux EEKG5048 User Manual
Diamond Multimedia XtremeTV PVR660 User Manual
Dell Flat Panel Monitor U3014 User Manual
Dell E173FP User Manual
Calphalon xl convention oven he650co User Manual
B B Electronics Computer Hardware 232CC2B User Manual
Avery MONARCH 939I User Manual
Analog Devices AD9272 User Manual