Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Information in this document is subject to change without notice.
© 2007-2009 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, and Dell OpenManage are trademarks of Dell Inc.; AMD and AMD Opteron are registered trademarks and AMD PowerNow!
is a trademark of Advanced Micro Devices; Microsoft, Windows, Windows Server, and MS-DOS are either trademarks or registered trademarks of Microsoft Corporation in the United
States and/or other countries; EMC is a registered trademark of EMC Corporation; Red Hat and Red Hat Linux are registered trademarks of Red Hat Inc.; UNIX is a registered
trademark of The Open Group in the United States and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
June 2009 P/N TT864 Rev. A01
the remote access controller (RAC) card. See the BMC User's Guide for more information on setup and use of BMC.
<Ctrl><C> This keystroke enters the SAS Configuration Utility. See your SAS controller User's Guide for more information.
<Ctrl><R> If you have the optional battery-cached SAS RAID controller, this keystroke enters the RAID configuration utility. For more information, see the
documentation for your SAS controller card.
<Ctrl><S> If you have PXE support enabled through the System Setup Program (see Integrated Devices Screen), this keystroke allows you to configure
NIC settings for PXE boot. For more information, see the documentation for your integrated NIC.
Front-Panel Features and Indicators
Figure 1-1 shows the controls, indicators, and connectors located behind the optional rack bezel on the system's front panel.
Figure 1-1. Front-Panel Features and Indicators
Table 1-2. Front-Panel LED Indicators, Buttons, and Connectors
Item Indicator, Button, or Icon
Connector
Description
1
Power-on indicator,
power button
The power-on indicator lights when the system power is on.
The power button controls the DC power supply output to the system. When the system bezel is installed, the power
button is not accessible.
NOTE: When powering on the system, the video monitor can take from several seconds to over 2 minutes to display
an image, depending on the amount of memory installed in the system.
NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to
perform a graceful shutdown before power to the system is turned off.
2
NMI button
Used to troubleshoot software and device driver errors when using certain operating systems. This button can be
pressed using the end of a paper clip.
Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.
3
4
System identification
button
The identification buttons on the front and back panels can be used to locate a particular system within a rack. When
one of these buttons is pushed, the LCD panel on the front and the blue system status indicator on the back blink
until one of the buttons is pushed again.
LCD panel
Provides system ID, status information, and system error messages.
The LCD lights during normal system operation. Both the systems management software and the identification
buttons located on the front and back of the system can cause the LCD to flash blue to identify a particular system.
The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by
descriptive text.
NOTE: If the system is connected to AC power and an error has been detected, the LCD lights amber regardless of
whether the system has been powered on.
5
6
USB connectors (2)
Connects USB devices to the system. The ports are USB 2.0-complaint.
Video connector
Hard drives (2)
Connects a monitor to the system.
7
8
One or two 2.5-inch hot plug
Optical drive
(optional)
One optional slim-line SATA DVD-ROM drive or DVD-RW drive, or combination CD-RW/DVD drive (when available).
NOTE: DVD devices are data only.
Hard-Drive Indicator Codes
The hard-drive carriers have two indicators—the drive-activity indicator and the drive-status indicator. See Figure 1-2. In RAID configurations, the drive-status
indicator lights to indicate the status of the drive. In non-RAID configurations, only the drive-activity indicator lights; the drive-status indicator is off.
Figure 1-2. Hard-Drive Indicators
1
drive-status indicator (green and amber)
2
green drive-activity indicator
Table 1-3 lists the drive indicator patterns for RAID hard drives. Different patterns are displayed as drive events occur in the system. For example, if a hard
drive fails, the "drive failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the
"drive ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" pattern appears, followed by
the "drive online" pattern.
NOTE: For non-RAID configurations, only the drive-activity indicator is active. The drive-status indicator is off.
Table 1-3. Hard-Drive Indicator Patterns for RAID
Condition
Drive-Status Indicator Pattern
Identify drive/preparing for removal Blinks green two times per second
Drive ready for insertion or removal Off
Drive predicted failure
Drive failed
Blinks green, amber, and off.
Blinks amber four times per second.
Blinks green slowly.
Drive rebuilding
Drive online
Steady green.
Rebuild aborted
Blinks green three seconds, amber three seconds, and off six seconds.
Back-Panel Features and Indicators
Figure 1-3. Back-Panel Features and Indicators
1
3
5
PCIe slot 1
2
4
6
PCIe slot 2
PCIe slot 3
PCIe slot 4
power supply bay 1 (PS1)
power supply bay 2 (PS2)
7
9
system identification button
8
system status indicator
system status indicator connector
10 LOM4 connector (Gb/10Gb)1
12 LOM2 connector (Gb)
11 LOM3 connector (Gb/10Gb)a
13 LOM1 connector (Gb)
14 2.0-compliant USB connectors (2)
16 serial connector
15 video connector
17 remote access controller (RAC) connector (optional)
Connecting External Devices
When connecting external devices to your system, follow these guidelines:
l
Most devices must be connected to a specific connector and device drivers must be installed before the device operates properly. (Device drivers are
normally included with your operating system software or with the device itself.) See the documentation that accompanied the device for specific
installation and configuration instructions.
l
Always attach external devices while your system and the device are turned off. Next, turn on any external devices before turning on the system
(unless the documentation for the device specifies otherwise).
For information about individual connectors, see Jumpers and Connectors. For information about enabling, disabling, and configuring I/O ports and connectors,
Power Indicator Codes
The power button on the front panel controls the power to the system from the system's power supplies. The power indicator lights green when the system is
on.
The indicators on the redundant power supplies show whether power is present or whether a power fault has occurred (see Figure 1-4). Table 1-4 lists the
power supply indicator codes.
Table 1-4. Redundant Power Supply Indicators
Indicator
Function
Power supply status Green indicates that the power supply is operational and providing DC power to the system.
Power supply fault
AC line status
Amber indicates a problem with the power supply.
Green indicates that a valid AC source is connected to the power supply and is operational.
Figure 1-4. Redundant Power Supply Indicators
1
3
power supply status
(DC out is operational)
2
power supply fault
AC line status (AC in is operational)
NIC Indicator Codes
Each NIC on the back panel has an indicator that provides information on network activity and link status. See Figure 1-5. Table 1-5 lists the NIC indicator
codes.
Figure 1-5. NIC Indicators
1
link indicator
2
activity indicator
Table 1-5. NIC Indicator Codes
Indicator
Indicator Code
Link and activity indicators are off The NIC is not connected to the network.
Link indicator is green
The NIC is connected to a valid link partner on the network.
Activity indicator is amber blinking Network data is being sent or received.
LCD Status Messages
The system's control panel LCD provides status messages to signify when the system is operating correctly or when the system needs attention.
The LCD lights blue to indicate a normal operating condition, and lights amber to indicate an error condition. The LCD scrolls a message that includes a status
code followed by descriptive text. Table 1-6 lists the LCD status messages that can occur and the probable cause for each message. The LCD messages refer
to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management
software documentation.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE: If your system fails to boot, press the System ID button for at least five seconds until an error code appears on the LCD. Record the code, then
Table 1-6. LCD Status Messages
Code Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that can be defined by the user This message is for information only.
in the System Setup program.
You can change the system ID and name in the System Setup program. See
The SYSTEM NAME displays under the following
conditions:
l
l
The system is powered on.
The power is off and active errors are
displayed.
E1000 FAILSAFE, Call
Support
Check the system event log for critical failure
events.
E1114 Temp Ambient
Ambient system temperature is out of acceptable
range.
E1118 CPU Temp
The BMC is unable to determine the CPU(s)
temperature status. Consequently, the BMC
increases the CPU fan speed to maximum
as a precautionary measure.
Turn off power to the system and restart the system. If the problem
Interface
E1210 CMOS Batt
E1211 ROMB Batt
CMOS battery is missing, or the voltage is out of
acceptable range.
RAID battery is either missing, bad, or unable to
recharge due to thermal issues.
E1214 ## PwrGd
Specified voltage regulator has failed.
E1216
E1217
E1218 PCI Rsr 5V PwrGd
The 5V voltage regulator on the PCI riser has
failed.
E121A 8V PwrGd
8V voltage regulator has failed.
Recycle power to the system or clear the SEL. If the problem persists, see
E121D 1.2V VM Dual
PwrGd
1.2V voltage regulator for the VM dual signal has
failed.
Recycle power to the system or clear the SEL. If the problem persists, see
E1226 PCI Rsr 1.5V
PwrGd
The 1.5V voltage regulator on the PCI riser has
failed.
E1227 Linear PwrGd
Linear voltage regulator(s) has failed. Represents
status of multiple voltage regulators used in the
video and LOM circuitry.
E1229 CPU # VCORE
Processor # VCORE voltage regulator has failed.
E122A CPU VTT PwrGd
Processor # VTT voltage has exceeded the
allowable voltage range
E122D CPU # VDDIO
Processor # VDDIO voltage has exceeded the
allowable voltage range
1.0V PwrGd
E122E CPU # VDDA
Processor # VDDA voltage has exceeded the
allowable voltage range
E122F 2.5V PwrGd
2.5V voltage regulator has failed.
E1231 1.2V HTCORE PwrGd 1.2V HTCORE voltage regulator has failed.
E1232 VDD 12V PS# PwrGd The specified power supply has failed or has been If removed, reinsert the power supply into the bay and reconnect to power.
removed from the bay while the system was on.
E123B LOM Mezz PwrGd
E123C Planar LOM PwrGd
E1310 RPM Fan ##
Voltage regulator for the LOM daughter card has
failed.
Recycle power to the system or clear the SEL. If the problem persists, see
Voltage regulator for the integrated LOM has
failed.
Recycle power to the system or clear the SEL. If the problem persists, see
RPM of specified cooling fan is out of acceptable
operating range.
E1313 Fan Redundancy
The system is no longer fan-redundant. Another
fan failure will put the system at risk of over-
heating.
Check control panel LCD for additional scrolling messages. See
E1414 CPU # Thermtrip
Specified microprocessor is out of acceptable
temperature range and has halted operation.
ensure that the microprocessor heat sinks are properly installed. See
NOTE: The LCD continues to display this message until the system's power
cord is disconnected and reconnected to the AC power source, or the SEL is
cleared using either Server Assistant or the BMC Management Utility. See
the Dell OpenManageâ„¢ Baseboard Management Controller User's Guide for
information about these utilities.
E1418 CPU # Presence
E141C CPU Mismatch
Specified processor is missing or bad, and the
system is in an unsupported configuration.
Processors are in a configuration unsupported by
Dell.
Ensure that your processors match and conform to the type described in
the Microprocessor Technical Specifications outlined in your system's Getting
Started Guide.
E141F CPU Protocol
E1421 CPU Init
The system BIOS has reported a processor
protocol error.
The system BIOS has reported a processor
initialization error.
E1422 CPU Machine Chk
E1610 PS # Missing
The system BIOS has reported a machine check
error.
No power is available from the specified power
supply; specified power supply is improperly
installed or faulty.
E1614 PS # Status
No power is available from the specified power
supply; specified power supply is improperly
installed or faulty.
E1618 PS # Predictive
Power supply voltage is out of acceptable range;
specified power supply is improperly installed or
faulty.
E161C PS # Input Lost
E1620 PS # Input Range
E1624 PS Redundancy
Power source for specified power supply is
unavailable, or out of acceptable range.
Check the AC power source for the specified power supply. If the problem
Power source for specified power supply is
unavailable, or out of acceptable range.
Check the AC power source for the specified power supply. If the problem
The power supply subsystem is no longer
redundant. If the last supply fails, the system will
go down.
E1625 PS AC Current
Power source is out of acceptable range.
Check the AC power source.
E1710 I/O Channel Chk
The system BIOS has reported an I/O channel
check.
E1711 PCI PERR B## D##
F##
The system BIOS has reported a PCI parity error
on a component that resides in PCI configuration
space at bus ##, device ##, function ##.
Remove and reseat the PCIe expansion cards. If the problem persists, see
PCI PERR Slot #
The system BIOS has reported a PCI parity error
on a component that resides in the specified PCIe
slot.
E1712 PCI SERR B## D##
F##
The system BIOS has reported a PCI system error Remove and reseat the PCIe expansion cards. If the problem persists, see
on a component that resides in PCI configuration
space at bus ##, device ##, function ##.
PCI SERR Slot #
The system BIOS has reported a PCI system error Reinstall the expansion-card riser. See Expansion-Card Risers.
on a component that resides in the specified slot.
E1714 Unknown Err
The system BIOS has determined that there has
been an error in the system, but is unable to
determine its origin.
E171F PCIE Fatal Err
B## D## F##
The system BIOS has reported a PCIe fatal error
space at bus ##, device ##, function ##.
Remove and reseat the PCIe expansion cards. If the problem persists, see
PCIE Fatal Err
Slot #
The system BIOS has reported a PCIe fatal error
on a component that resides in the specified slot.
E1810 HDD ## Fault
The SAS subsystem has determined that hard
drive ## has experienced a fault.
E1811 HDD ## Rbld Abrt
E1812 HDD ## Removed
E1914 DRAC5 Conn2 Cbl
The specified hard drive has experienced a rebuild See Troubleshooting a Hard Drive. If the problem persists, see your RAID
abort.
documentation.
The specified hard drive has been removed from
the system.
Information only.
DRAC 5 cable is missing or disconnected.
E1915 IO55 HTSink
Missing
Heatsink sensor reports that the chipset IO55
heatsink is missing.
Heatsink sensor reports that the chipset MCP
heatsink heatsink is missing.
MCP55 Htsink
Missing
E1A12 PCI Rsr Missing
One or all of the PCIe risers is missing, preventing Reinstall the missing riser card(s).
the system from powering on.
E1A14 SAS Cable A
SAS cable A is missing or bad.
SAS cable B is missing or bad.
LOM daughter card is missing.
E1A15 SAS Cable B
E1A1C LOM Mezz Missing
E1B01 USB# Overcurrent
Install or reseat the LOM daughter card. If the problem persists, replace the
Device plugged in the specified USB port caused
an overcurrent condition.
Reseat the device cable. If the problem persists, replace or remove the
device.
E2010 No Memory
No memory is installed in the system.
E2011 Mem Config Err
Memory detected, but is not configurable. Error
detected during memory configuration.
E2012 Unusable Memory
E2013 Shadow BIOS Fail
Memory is configured, but not usable. Memory
subsystem failure.
memory.
E2014 CMOS Fail
CMOS failure. CMOS RAM not functioning properly.
DMA controller failure.
E2015 DMA Controller
E2016 Int Controller
E2017 Timer Fail
E2018 Prog Timer
E2019 Parity Error
E201A SIO Err
Interrupt controller failure.
Timer refresh failure.
Programmable interval timer error.
Parity error.
SIO failure.
E201B Kybd Controller
E201C SMI Init
Keyboard controller failure.
System management interrupt (SMI) initialization
failure.
E201D Shutdown Test
E201E POST Mem Test
E201F DRAC Config
BIOS shutdown test failure.
BIOS POST memory test failure.
Dell remote access controller (DRAC) configuration Check screen for specific error messages.
failure.
Ensure that DRAC cables and connectors are properly seated. If problem
persists, see your DRAC documentation.
E2020 CPU Config
CPU configuration failure.
Check screen for specific error messages.
E2021 Memory Population Incorrect memory configuration. Memory
population order incorrect.
E2022 POST Fail
General failure after video.
Check screen for specific error messages.
E2110 MBE DIMM # & #
has had a memory multi-bit error (MBE).
E2111 SBE Log Disable
DIMM #
The system BIOS has disabled memory single-bit
error (SBE) logging, and will not resume logging
further SBEs until the system is rebooted. "#"
represents the DIMM implicated by the BIOS.
E2112 Mem Spare DIMM #
it has determined that the memory had too many
errors. "# & #" represents the DIMM pair
implicated by the BIOS.
I1910 Intrusion
System cover has been removed.
LCD overflow message.
Information only.
I1911 >3 ERRs Chk Log
Check the SEL for details on the events.
A maximum of three error messages can display
sequentially on the LCD. The fourth message
displays as the standard overflow message.
I1912 SEL Full
I1915 Video Off
System Event Log is full of events, and is unable
to log any more events.
Clear the log by deleting event entries.
Information only.
The video has been turned off by the RAC remote
user.
(LCD lights with a
blue or amber
background.)
I1916 Video Off in ##
The video will be turned off in xx seconds by the
Information only.
RAC remote user.
(LCD lights with a
blue or amber
background.)
W1228 ROMB Batt < 24hr
Warns predictively that the RAID battery has less
than 24 hours of charge left.
Solving Problems Described by LCD Status Messages
The code and text on the LCD can often specify a very precise fault condition that is easily corrected. For example, if the code E1418 CPU_1_Presence
appears, you know that a microprocessor is not installed in socket 1.
In contrast, you might be able to determine the problem if multiple related errors occur. For example, if you receive a series of messages indicating multiple
voltage faults, you might determine that the problem is a failing power supply.
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a
normal state. For example, if temperature for a component goes out of range, the LCD displays the fault; when the temperature returns to the acceptable
range, the message is removed from the LCD. For other faults, you must take action to remove the message from the display:
l
l
Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.
Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately ten seconds, reconnect the power cable, and restart
the system.
Any of these actions will remove fault messages, and return the status indicators and LCD colors to the normal state. Messages will reappear under the
following conditions:
l
l
l
The sensor returns to a normal state but fails again, resulting in a new SEL entry.
The system is reset and new error events are detected.
A failure is recorded from another source that maps to the same display entry.
System Messages
System messages appear on the screen to notify you of a possible problem with the system. Table 1-3 lists the system messages that can occur and the
probable cause and corrective action for each message.
NOTE: If you receive a system message that is not listed in Table 1-3, check the documentation for the application that is running when the message
appears or the operating system's documentation for an explanation of the message and recommended action.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Table 1-7. System Messages
Message
Causes
Corrective Actions
Alert! Node Interleaving disabled!
Memory configuration does not support
Node Interleaving.
The memory configuration does not support
node interleaving, or the configuration has
changed (for example, a failed DIMM) so that
node interleaving cannot be supported. The
system will run but with reduced functionality.
Ensure that the memory modules are installed in a
configuration that supports node interleaving. Check other
system messages for additional information for possible
Attempting to update Remote
Remote Configuration request has been
Wait until the process is complete.
detected and is being processed.
Remote BIOS update attempt failed.
Configuration. Please wait...
BIOS Update Attempt Failed!
Caution! NVRAM_CLR jumper is installed NVRAM_CLR jumper is installed. CMOS has
location.
been cleared.
on system board.
CPUs with different cache sizes
detected!
Microprocessors with different cache sizes are
installed.
Ensure that all microprocessors have the same cache size and
Decreasing available memory
Error: Incorrect memory configuration
The DIMM group for CPU n is incorrectly
configured and caused the system to halt.
configuration information. If the problem persists, see
CPU n
!!*** Error: Remote Access Controller
initialization failure *** RAC virtual
USB devices may not be available...
Remote Access Controller initialization failure
Ensure that the Remote Access Controller is properly installed.
Gate A20 failure
Faulty keyboard controller; faulty system
board.
General failure
The operating system is unable to carry out
the command.
This message is usually followed by specific information. Note
the information, and take the appropriate action to resolve the
problem.
HyperTransport error caused a system
reset! Please check the system event
log for details!
A fatal system error occurred and caused the
system to reboot.
Check the SEL for information that was logged during the
error. See the applicable troubleshooting section in
Troubleshooting Your System for any faulty components
specified in the SEL.
Invalid NVRAM configuration, Resource
Re-allocated
System detected and corrected a resource
conflict.
No action is required.
Invalid PCIe card found in the
Internal_Storage slot!
The system halted because an invalid PCIe
expansion card is installed in the dedicated
storage controller slot.
Remove the PCIe expansion card and install either the internal
SAS controller in the dedicated slot.
Keyboard Controller failure
Manufacturing mode detected
System is in manufacturing mode. Reboot to take the system out of manufacturing mode.
Memory address line failure at address, Faulty or improperly installed memory modules. See Troubleshooting System Memory.
read value expecting value
Memory double word logic failure at
address, read value expecting value
Memory odd/even logic failure at
address, read value expecting value
Memory write/read failure at address,
read value expecting value
Memory tests terminated by keystroke.
No boot device available
POST memory test terminated by pressing the
spacebar.
Information only.
Faulty or missing optical drive subsystem, hard Use a bootable USB key, CD, or hard drive. If the problem
drive, or hard-drive subsystem, or no bootable persists, see Troubleshooting an SD Card or Internal USB Key
USB key installed.
No boot sector on hard drive
Incorrect configuration settings in System
Setup program, or no operating system on
hard drive.
Check the hard-drive configuration settings in the System
necessary, install the operating system on your hard drive.
See your operating system documentation.
No timer tick interrupt
Optical drive not found
Faulty system board.
Cable is not properly seated, or drive missing.
PCI BIOS failed to install
PCIe device BIOS (Option ROM) checksum
failure detected during shadowing.
Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s). If the
Cables to expansion card(s) loose; faulty or
improperly installed expansion card(s).
PCIe Degraded Link Width Error:
Faulty system board or riser board.
Embedded device
Expected Link Width is n
Actual Link Width is n
PCIe Degraded Link Width Error:
Integrated device
The specified PCIe device is faulty or
improperly installed.
For a SAS controller daughter card, reseat the card in the
Expected Link Width is n
Actual Link Width is n
PCIe Degraded Link Width Error: Slot n Faulty or improperly installed PCIe card in the
Reseat the PCIe card in the specified slot number. See
specified slot.
Expected Link Width is n
Actual Link Width is n
PCIe Training Error: Embedded device
Faulty system board or riser board.
PCIe Training Error: Integrated device The specified PCIe device is faulty or
For a SAS controller daughter card, reseat the card in the
improperly installed.
PCIe Training Error: Slot n
Faulty or improperly installed PCIe card in the
specified slot.
Reseat the PCIe card in the specified slot number. See
Plug & Play Configuration Error
Error encountered in initializing PCIe device;
faulty system board.
Install the NVRAM_CLR jumper and reboot the system. See
Read fault
The operating system cannot read from the
Replace the USB medium or device. Ensure that the USB or
hard drive or USB device, the system could not hard drive cables are properly connected. See Troubleshooting
find a particular sector on the disk, or the
requested sector is defective.
appropriate drive(s) installed in your system.
Requested sector not found
Remote Access Controller cable error or
incorrect card in the RAC slot.
RAC cables not connected, or RAC card
installed in wrong expansion slot.
Check that the RAC cables are connected, and that the RAC
Remote configuration update attempt
failed
System unable to process Remote
Configuration request
Retry Remote Configuration.
ROM bad checksum = address
Expansion card improperly installed or faulty.
Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s). If the
Sector not found
Seek error
Faulty hard drive, USB device, or. USB medium. See Troubleshooting a USB Device or Troubleshooting a Hard
Seek operation failed
Shutdown failure
Shutdown test failure.
The amount of system memory has changed Memory has been added or removed or a
If memory has been added or removed, this message is
informative and can be ignored. If memory has not been added
or removed, check the SEL to determine if single-bit or multi-bit
errors were detected and replace the faulty memory module.
memory module may be faulty.
This system supports only Opteron(TM)
2000 series processors.
Microprocessor(s) is not supported by the
system.
Install a supported microprocessor or microprocessor
Time-of-day clock stopped
Faulty battery or faulty chip.
Time-of-day not set - please run SETUP Incorrect Time or Date settings; faulty system
battery.
program
Timer chip counter 2 failed
Unsupported CPU combination
Faulty system board.
Microprocessor(s) is not supported by the
system.
Install a supported microprocessor or microprocessor
Unsupported CPU stepping detected
TPM failure
A Trusted Platform Module (TPM) function has
failed.
Utility partition not available
The <F10> key was pressed during POST, but
no utility partition exists on the boot hard
drive.
Create a utility partition on the boot hard drive. See the CDs
that came with your system.
Warning: Following faulty DIMMs are
disabled:
DIMMs are disabled in pairs, as indicated by
the n1 and n2. Check both DIMMs for a
possible fault.
DIMM n1 n2
Total memory size is reduced.
Warning: A fatal error has caused
system reset! Please check the system
event log!
A fatal system error occurred and caused the
system to reboot.
Check the SEL for information that was logged during the
error. See the applicable troubleshooting section in
Troubleshooting Your System for any faulty components
specified in the SEL.
Warning! No micro code update loaded
Micro code update failed.
for processor n
Warning: One or more faulty DIMMs found
on CPUn
used by CPUn.
Warning: The installed memory
configuration is not optimal. For more
information on valid memory
configurations, please see the system
documentation on the technical support
web site.
Invalid memory configuration. The system will
run but with reduced functionality.
Ensure that the memory modules are installed in a valid
Write fault
Faulty USB device, USB medium, optical drive
assembly, hard drive, or hard-drive subsystem. Card or Internal USB Key, and Troubleshooting a Hard Drive.
Write fault on selected drive
Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard
drive, a message will warn you that you may lose all data on the hard drive. Warning messages usually interrupt the task and require you to respond by
typing y(yes) or n(no).
NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that
accompanied the operating system or application.
Diagnostics Messages
When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of
the Diagnostics Checklist in Getting Help, and then follow the instructions in that section for obtaining technical assistance.
Alert Messages
Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for
drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Information in this document is subject to change without notice.
© 2007-2009 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, and Dell OpenManage are trademarks of Dell Inc.; AMD and AMD Opteron are registered trademarks and AMD PowerNow!
is a trademark of Advanced Micro Devices; Microsoft, Windows, Windows Server, and MS-DOS are either trademarks or registered trademarks of Microsoft Corporation in the United
States and/or other countries; EMC is a registered trademark of EMC Corporation; Red Hat and Red Hat Linux are registered trademarks of Red Hat Inc.; UNIX is a registered
trademark of The Open Group in the United States and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
June 2009 P/N TT864 Rev. A01
Running the System Diagnostics
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your
system's hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can
use diagnostics test results to help you solve the problem.
Using Server Administrator Diagnostics
To assess a system problem, first use the online Server Administrator diagnostics. If you are unable to identify the problem, then use the system diagnostics.
To access the online diagnostics, log into the Server Administrator home page, and then click the Diagnostics tab. For information about using diagnostics, see
the online help. For additional information, see the Server Administrator User's Guide.
System Diagnostics Features
The system diagnostics provides a series of menus and options for particular device groups or devices. The system diagnostics menus and options allow you
to:
l
l
l
l
l
l
l
l
Run tests individually or collectively.
Control the sequence of tests.
Repeat tests.
Display, print, or save test results.
Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is reached.
View help messages that briefly describe each test and its parameters.
View status messages that inform you if tests are completed successfully.
View error messages that inform you of problems encountered during testing.
When to Use the System Diagnostics
If a major component or device in the system does not operate properly, component failure may be indicated. As long as the microprocessor and the system's
input/output devices (monitor, keyboard, and diskette drive) are functioning, you can use the system diagnostics to help identify the problem.
Running the System Diagnostics
The system diagnostics is run from the utility partition on your hard drive.
NOTICE: Use the system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages. In
addition, use only the program that came with your system (or an updated version of that program).
1. As the system boots, press <F10> during POST.
2. From the utility partition main menu, select Run System Diagnostics, or select Run Memory Diagnostics if you are troubleshooting memory.
When you start the system diagnostics, a message is displayed stating that the diagnostics are initializing. Next, the Diagnostics menu appears. The menu
allows you to run all or specific diagnostics tests or to exit the system diagnostics.
NOTE: Before you read the rest of this section, start the system diagnostics so that you can see the utility on your screen.
System Diagnostics Testing Options
Click the testing option in the Main Menu window. Table 5-1 provides a brief explanation of testing options.
Table 5-1. System Diagnostics Testing Options
Testing
Option
Function
Express Test
Performs a quick check of the system. This option runs device tests that do not require user interaction. Use this option to quickly identify the
source of your problem.
Extended Test Performs a more thorough check of the system. This test can take an hour or longer.
Custom Test
Information
Tests a particular device.
Displays test results.
Using the Custom Test Options
When you select Custom Test in the Main Menu window, the Customize window appears and allows you to select the device(s) to be tested, select specific
options for testing, and view the test results.
Selecting Devices for Testing
The left side of the Customize window lists devices that can be tested. Devices are grouped by device type or by module, depending on the option you select.
Click the (+) next to a device or module to view its components. Click (+) on any component to view the tests that are available. Clicking a device, rather
than its components, selects all of the components of the device for testing.
Selecting Diagnostics Options
Use the Diagnostics Options area to select how you want to test a device. You can set the following options:
l
l
l
l
l
Non-Interactive Tests Only — When checked, runs only tests that require no user intervention.
Quick Tests Only — When checked, runs only the quick tests on the device. Extended tests will not run when you select this option.
Show Ending Timestamp — When checked, time stamps the test log.
Test Iterations — Selects the number of times the test is run.
Log output file pathname — When checked, enables you to specify where the test log file is saved.
Viewing Information and Results
The tabs in the Customize window provide information about the test and the test results. The following tabs are available:
l
l
l
l
l
Results — Displays the test that ran and the result.
Errors — Displays any errors that occurred during the test.
Help — Displays information about the currently selected device, component, or test.
Configuration — Displays basic configuration information about the currently selected device.
Parameters — If applicable, displays parameters that you can set for the test.
Getting Help
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
Contacting Dell
For customers in the United States, call 800-WWW-DELL (800-999-3355).
NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product
catalog.
Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be
available in your area. To contact Dell for sales, technical support, or customer service issues:
1. Visit support.dell.com.
2. Verify your country or region in the Choose A Country/Region drop-down menu at the bottom of the page.
3. Click Contact Us on the left side of the page.
4. Select the appropriate service or support link based on your need.
Choose the method of contacting Dell that is convenient for you.
Glossary
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
This section defines or identifies technical terms, abbreviations, and acronyms used in your system documents.
A — Ampere(s).
AC — Alternating current.
ACPI — Advanced Configuration and Power Interface. A standard interface for enabling the operating system to direct configuration and power
management.
ambient temperature — The temperature of the area or room where the system is located.
ANSI — American National Standards Institute. The primary organization for developing technology standards in the U.S.
application — Software designed to help you perform a specific task or series of tasks. Applications run from the operating system.
ASCII — American Standard Code for Information Interchange.
asset tag — An individual code assigned to a system, usually by an administrator, for security or tracking purposes.
backup — A copy of a program or data file. As a precaution, back up your system's hard drive on a regular basis. Before making a change to the
configuration of your system, back up important start-up files from your operating system.
backup battery — A battery that maintains system configuration, date, and time information in a special section of memory when the system is turned off.
beep code — A diagnostic message in the form of a pattern of beeps from your system's speaker. For example, one beep, followed by a second beep, and
then a burst of three beeps is beep code 1-1-3.
BIOS — Basic input/output system. Your system's BIOS contains programs stored on a flash memory chip. The BIOS controls the following:
l
l
Communications between the processor and peripheral devices
Miscellaneous functions, such as system messages
bit — The smallest unit of information interpreted by your system.
blade — A module that contains a processor, memory, and a hard drive. The modules are mounted into a chassis that includes power supplies and fans.
BMC — Baseboard management controller.
boot routine — A program that clears all memory, initializes devices, and loads the operating system when you start your system. Unless the operating
system fails to respond, you can reboot (also called warm boot) your system by pressing <Ctrl><Alt><Del>. Otherwise, you must restart the system by
pressing the reset button or by turning the system off and then back on.
bootable diskette — A diskette that is used to start your system if the system will not boot from the hard drive.
BTU — British thermal unit.
bus — An information pathway between the components of a system. Your system contains an expansion bus that allows the processor to communicate
with controllers for the peripheral devices connected to the system. Your system also contains an address bus and a data bus for communications between
the processor and RAM.
C — Celsius.
cache — A fast storage area that keeps a copy of data or instructions for quick data retrieval. When a program makes a request to a disk drive for data that
is in the cache, the disk-cache utility can retrieve the data from RAM faster than from the disk drive.
CD — Compact disc. CD drives use optical technology to read data from CDs.
cm — Centimeter(s).
cmos — Complementary metal-oxide semiconductor.
component — As they relate to DMI, components include operating systems, computer systems, expansion cards, and peripherals that are compatible with
DMI. Each component is made up of groups and attributes that are defined as relevant to that component.
COMn — The device names for the serial ports on your system.
control panel — The part of the system that contains indicators and controls, such as the power button and power indicator.
controller — A chip that controls the transfer of data between the processor and memory or between the processor and a peripheral.
conventional memory — The first 640 KB of RAM. Conventional memory is found in all systems. Unless they are specially designed, MS-DOS® programs are
limited to running in conventional memory.
coprocessor — A chip that relieves the system's processor of specific processing tasks. A math coprocessor, for example, handles numeric processing.
CPU — Central processing unit. See processor.
DC — Direct current.
DDR — Double-data rate. A technology in memory modules that potentially doubles the output.
device driver — A program that allows the operating system or some other program to interface correctly with a peripheral. Some device drivers—such as
network drivers—must be loaded from the config.sys file or as memory-resident programs (usually, from the autoexec.bat file). Others must load when you
start the program for which they were designed.
DHCP — Dynamic Host Configuration Protocol. A method of automatically assigning an IP address to a client system.
diagnostics — A comprehensive set of tests for your system.
DIMM — Dual in-line memory module. See also memory module.
DIN — Deutsche Industrie Norm.
directory — Directories help keep related files organized on a disk in a hierarchical, "inverted tree" structure. Each disk has a "root" directory. Additional
directories that branch off the root directory are called subdirectories. Subdirectories may contain additional directories branching off them.
DMA — Direct memory access. A DMA channel allows certain types of data transfer between RAM and a device to bypass the processor.
DMI — Desktop Management Interface. DMI enables the management of your system's software and hardware by collecting information about the system's
components, such as the operating system, memory, peripherals, expansion cards, and asset tag.
DNS — Domain Name System. A method of translating Internet domain names, such as www.dell.com, into IP addresses, such as 143.166.83.200.
DRAM — Dynamic random-access memory. A system's RAM is usually made up entirely of DRAM chips.
DVD — Digital versatile disc.
ECC — Error checking and correction.
EEPROM — Electronically erasable programmable read-only memory.
EMC — Electromagnetic compatibility.
EMI — Electromagnetic interference.
ERA — Embedded remote access. ERA allows you to perform remote, or "out-of-band," server management on your network server using a remote access
controller.
ESD — Electrostatic discharge.
ESM — Embedded server management.
expansion bus — Your system contains an expansion bus that allows the processor to communicate with controllers for peripherals, such as NICs.
expansion card — An add-in card, such as a NIC or SCSI adapter, that plugs into an expansion-card connector on the system board. An expansion card adds
some specialized function to the system by providing an interface between the expansion bus and a peripheral.
expansion-card connector — A connector on the system board or riser board for plugging in an expansion card.
F — Fahrenheit.
FAT — File allocation table. The file system structure used by MS-DOS to organize and keep track of file storage. The Microsoft® Windows® operating
systems can optionally use a FAT file system structure.
flash memory — A type of EEPROM chip that can be reprogrammed from a utility on diskette while still installed in a system; most EEPROM chips can only be
rewritten with special programming equipment.
format — To prepare a hard drive or diskette for storing files. An unconditional format deletes all data stored on the disk.
FSB — Front-side bus. The FSB is the data path and physical interface between the processor and the main memory (RAM).
ft — Feet.
FTP — File transfer protocol.
g — Gram(s).
G — Gravities.
Gb — Gigabit(s); 1024 megabits or 1,073,741,824 bits.
GB — Gigabyte(s); 1024 megabytes or 1,073,741,824 bytes. However, when referring to hard-drive capacity, the term is usually rounded to 1,000,000,000
bytes.
graphics mode — A video mode that can be defined as x horizontal by y vertical pixels by z colors.
group — As it relates to DMI, a group is a data structure that defines common information, or attributes, about a manageable component.
guarding — A type of data redundancy in which a set of physical drives stores data and an additional drive stores parity data. See also mirroring, striping,
and RAID.
h — Hexadecimal. A base-16 numbering system, often used in programming to identify addresses in the system's RAM and I/O memory addresses for
devices. In text, hexadecimal numbers are often followed by h.
headless system — A system or device that functions without having a keyboard, mouse, or monitor attached. Normally, headless systems are managed
over a network using an Internet browser.
host adapter — A host adapter implements communication between the system's bus and the controller for a peripheral device. (Hard-drive controller
subsystems include integrated host adapter circuitry.) To add a SCSI expansion bus to your system, you must install or connect the appropriate host
adapter.
Hz — Hertz.
I/O — Input/output. A keyboard is an input device, and a monitor is an output device. In general, I/O activity can be differentiated from computational
activity.
ID — Identification.
IDE — Integrated drive electronics. A standard interface between the system board and storage devices.
integrated mirroring — Provides simultaneous physical mirroring of two drives. Integrated mirroring functionality is provided by the system's hardware. See
also mirroring.
internal processor cache — An instruction and data cache built into the processor.
IP — Internet Protocol.
IPX — Internet package exchange.
IRQ — Interrupt request. A signal that data is about to be sent to or received by a peripheral device travels by an IRQ line to the processor. Each peripheral
connection must be assigned an IRQ number. Two devices can share the same IRQ assignment, but you cannot operate both devices simultaneously.
jumper — Small blocks on a circuit board with two or more pins emerging from them. Plastic plugs containing a wire fit down over the pins. The wire connects
the pins and creates a circuit, providing a simple and reversible method of changing the circuitry in a board.
K — Kilo-; 1000.
Kb — Kilobit(s); 1024 bits.
KB — Kilobyte(s); 1024 bytes.
Kbps — Kilobit(s) per second.
KBps — Kilobyte(s) per second.
key combination — A command requiring you to press multiple keys at the same time (for example, <Ctrl><Alt><Del>).
kg — Kilogram(s); 1000 grams.
kHz — Kilohertz.
KMM — Keyboard/monitor/mouse.
KVM — Keyboard/video/mouse. KVM refers to a switch that allows selection of the system from which the video
is displayed and for which the keyboard and mouse are used.
LAN — Local area network. A LAN is usually confined to the same building or a few nearby buildings, with all equipment linked by wiring dedicated specifically
to the LAN.
lb — Pound(s).
LCD — Liquid crystal display.
LED — Light-emitting diode. An electronic device that lights up when a current is passed through it.
LGA—Land grid array. A type of processor socket. Unlike the PGA, the LGA interface has no pins on the chip; instead, the chip has pads that contact pins on
the system board.
Linux — An operating system similar to the UNIX® operating system that runs on a variety of hardware systems. Linux is open source software, which is
freely available; however, the full distribution of Linux along with technical support and training are available for a fee from vendors such as Red Hat®
Linux® software.
local bus — On a system with local-bus expansion capability, certain peripheral devices (such as the video adapter circuitry) can be designed to run much
faster than they would with a traditional expansion bus. See also bus.
LVD — Low voltage differential.
m — Meter(s).
mA — Milliampere(s).
MAC address — Media Access Control address. Your system's unique hardware number on a network.
mAh — Milliampere-hour(s).
Mb — Megabit(s); 1,048,576 bits.
MB — Megabyte(s); 1,048,576 bytes. However, when referring to hard-drive capacity, the term is often rounded to mean 1,000,000 bytes.
Mbps — Megabits per second.
MBps — Megabytes per second.
MBR — Master boot record.
memory address — A specific location, usually expressed as a hexadecimal number, in the system's RAM.
memory module — A small circuit board containing DRAM chips that connects to the system board.
memory — An area in your system that stores basic system data. A system can contain several different forms of memory, such as integrated memory (ROM
and RAM) and add-in memory modules (DIMMs).
MHz — Megahertz.
mirroring — A type of data redundancy in which a set of physical drives stores data and one or more sets of additional drives stores duplicate copies of the
data. Mirroring functionality is provided by software. See also guarding, integrated mirroring, striping, and RAID.
mm — Millimeter(s).
ms — Millisecond(s).
NAS — Network Attached Storage. NAS is one of the concepts used for implementing shared storage on a network. NAS systems have their own operating
systems, integrated hardware, and software that are optimized to serve specific storage needs.
NIC — Network interface controller. A device that is installed or integrated in a system to allow connection to a network.
NMI — Nonmaskable interrupt. A device sends an NMI to signal the processor about hardware errors.
ns — Nanosecond(s).
NTFS — The NT File System option in the Windows 2000 operating system.
NVRAM — Nonvolatile random-access memory. Memory that does not lose its contents when you turn off your system. NVRAM is used for maintaining the
date, time, and system configuration information.
parity — Redundant information that is associated with a block of data.
partition — You can divide a hard drive into multiple physical sections called partitions with the fdisk command. Each partition can contain multiple logical
drives. You must format each logical drive with the format command.
PCI — Peripheral Component Interconnect. A standard for local-bus implementation.
PDU — Power distribution unit. A power source with multiple power outlets that provides electrical power to servers and storage systems in a rack.
peripheral — An internal or external device, such as a diskette drive or keyboard, connected to a system.
PGA — Pin grid array. A type of processor socket that allows you to remove the processor chip.
pixel — A single point on a video display. Pixels are arranged in rows and columns to create an image. A video resolution, such as 640 x 480, is expressed
as the number of pixels across by the number of pixels up and down.
POST — Power-on self-test. Before the operating system loads when you turn on your system, the POST tests various system components such as RAM and
hard drives.
processor — The primary computational chip inside the system that controls the interpretation and execution of arithmetic and logic functions. Software
written for one processor must usually be revised to run on another processor. CPU is a synonym for processor.
protected mode — An operating mode that allows operating systems to implement:
l
l
l
A memory address space of 16 MB to 4 GB
Multitasking
Virtual memory, a method for increasing addressable memory by using the hard drive
The Windows 2000 and UNIX 32-bit operating systems run in protected mode. MS-DOS cannot run in protected mode.
PS/2 — Personal System/2.
PXE — Preboot eXecution Environment. A way of booting a system via a LAN (without a hard drive or bootable diskette).
RAC — Remote access controller.
RAID — Redundant array of independent disks. A method of providing data redundancy. Some common implementations of RAID include RAID 0, RAID 1,
RAID 5, RAID 10, and RAID 50. See also guarding, mirroring, and striping.
RAM — Random-access memory. The system's primary temporary storage area for program instructions and data. Any information stored in RAM is lost when
you turn off your system.
RAS — Remote Access Service. This service allows users running the Windows operating system to remotely access a network from their system using a
modem.
readme file — A text file, usually shipped with software or hardware, that contains information supplementing or updating the product's documentation.
read-only file — A read-only file is one that you are prohibited from editing or deleting.
ROM — Read-only memory. Your system contains some programs essential to its operation in ROM code. A ROM chip retains its contents even after you turn
off your system. Examples of code in ROM include the program that initiates your system's boot routine and the POST.
ROMB — RAID on motherboard.
rpm — Revolutions per minute.
RTC — Real-time clock.
SAS — Serial-attached SCSI.
SATA — Serial Advanced Technology Attachment. A standard interface between the system board and storage devices.
SCSI — Small computer system interface. An I/O bus interface with faster data transmission rates than standard ports.
SDRAM — Synchronous dynamic random-access memory.
sec — Second(s).
serial port — An I/O port used most often to connect a modem to your system. You can usually identify a serial port on your system by its 9-pin connector.
service tag — A bar code label on the system used to identify it when you call Dell™ for technical support.
simple disk volume — The volume of free space on a single dynamic, physical disk.
SMART — Self-Monitoring Analysis and Reporting Technology. Allows hard drives to report errors and failures to the system BIOS and then display an error
message on the screen.
SMP — Symmetric multiprocessing. Used to describe a system that has two or more processors connected via a high-bandwidth link and managed by an
operating system, where each processor has equal access to I/O devices.
SNMP — Simple Network Management Protocol. A standard interface that allows a network manager to remotely monitor and manage workstations.
spanning — Spanning, or concatenating, disk volumes combines unallocated space from multiple disks into one logical volume, allowing more efficient use of
all the space and all drive letters on a multiple-disk system.
striping — Disk striping writes data across three or more disks in an array, but only uses a portion of the space on each disk. The amount of space used by a
"stripe" is the same on each disk used. A virtual disk may use several stripes on the same set of disks in an array. See also guarding, mirroring, and RAID.
SVGA — Super video graphics array. VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than
previous standards.
system board — As the main circuit board, the system board usually contains most of your system's integral components, such as the processor, RAM,
controllers for peripherals, and various ROM chips.
system configuration information — Data stored in memory that tells a system what hardware is installed and how the system should be configured for
operation.
system diskette — See bootable diskette.
system memory — See RAM.
System Setup program — A BIOS-based program that allows you to configure your system's hardware and customize the system's operation by setting
features such as password protection. Because the System Setup program is stored in NVRAM, any settings remain in effect until you change them again.
system.ini file — A start-up file for the Windows operating system. When you start Windows, it consults the system.ini file to determine a variety of options
for the Windows operating environment. Among other things, the system.ini file records which video, mouse, and keyboard drivers are installed for
Windows.
TCP/IP — Transmission Control Protocol/Internet Protocol.
termination — Some devices (such as the last device at each end of a SCSI cable) must be terminated to prevent reflections and spurious signals in the
cable. When such devices are connected in a series, you may need to enable or disable the termination on these devices by changing jumper or switch
settings on the devices or by changing settings in the configuration software for the devices.
UNIX — Universal Internet Exchange. UNIX, the precursor to Linux, is an operating system written in the C programming language.
uplink port — A port on a network hub or switch used to connect to other hubs or switches without requiring a crossover cable.
UPS — Uninterruptible power supply. A battery-powered unit that automatically supplies power to your system in the event of an electrical failure.
USB — Universal Serial Bus. A USB connector provides a single connection point for multiple USB-compliant devices, such as mice and keyboards. USB devices
can be connected and disconnected while the system is running.
utility — A program used to manage system resources—memory, disk drives, or printers, for example.
UTP — Unshielded twisted pair. A type of wiring used to connect systems in a business or home to a telephone line.
V — Volt(s).
VAC — Volt(s) alternating current.
VDC — Volt(s) direct current.
VGA — Video graphics array. VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than previous
standards.
video adapter — The logical circuitry that provides (in combination with the monitor) your system's video capabilities. A video adapter may be integrated into
the system board or may be an expansion card that plugs into an expansion slot.
video driver — A program that allows graphics-mode application programs and operating systems to display at a chosen resolution with the desired number
of colors. Video drivers may need to match the video adapter installed in the system.
video memory — Most VGA and SVGA video adapters include memory chips in addition to your system's RAM. The amount of video memory installed primarily
influences the number of colors that a program can display (with the appropriate video drivers and monitor capabilities).
video resolution — Video resolution (800 x 600, for example) is expressed as the number of pixels across by the number of pixels up and down. To display a
program at a specific graphics resolution, you must install the appropriate video drivers and your monitor must support the resolution.
W — Watt(s).
WH — Watt-hour(s).
win.ini file — A start-up file for the Windows operating system. When you start Windows, it consults the win.ini file to determine a variety of options for the
Windows operating environment. The win.ini file also usually includes sections that contain optional settings for Windows application programs that are
installed on the hard drive.
Windows 2000 — An integrated and complete Microsoft Windows operating system that does not require MS-DOS and that provides advanced operating
system performance, improved ease of use, enhanced workgroup functionality, and simplified file management and browsing.
Windows Powered — A Windows operating system designed for use on NAS systems. For NAS systems, the Windows Powered operating system is
dedicated to file service for network clients.
Windows Server 2003 — A set of Microsoft software technologies that enable software integration through the use of XML Web services. XML Web services
are small reusable applications written in XML that allow data to be communicated between otherwise unconnected sources.
XML — Extensible Markup Language. XML is a way to create common information formats and to share both the format and the data on the World Wide
Web, intranets, and elsewhere.
ZIF — Zero insertion force.
Installing System Components
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
This section describes how to install the following system components:
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Front bezel
Hard drives and hard-drive carriers
Power supplies
Internal SD card
System fans
SAS controller daughter card
RAID battery
Internal USB memory key
Expansion cards
Cooling shrouds
Fan brackets
Expansion-card risers
RAC card
LOM daughter card
Optical drive
System memory
Processors
System battery
Sideplane board
SAS/SATA backplane board
Control panel assembly
System board
Recommended Tools
You may need the following items to perform the procedures in this section:
l
l
l
l
Key to the system keylock
#1 and #2 Phillips screwdrivers
T-10 Torx driver
Wrist grounding strap
Inside the System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Figure 3-1. Inside the System
1
3
5
7
9
SAS controller daughter card
memory modules (up to 16)
cooling shrouds (3)
2
4
6
8
sideplane
hot-pluggable power supply cooling fans (2)
riser 2 (PCIe slots 3 and 4)
LOM daughter card
power supplies (1 or 2)
RAC daughter card
10 riser 1 (PCIe slots 1 and 2)
12 hot-pluggable processor fans (4)
14 SAS/SATA backplane
11 heatsinks/microprocessors (2)
13 slimline optical drive (optional)
15 RAID battery (optional battery-cached SAS RAID controller only) 16 SAS or SATA hard drives (1 or 2)
17 control panel
The system board holds the system's control circuitry and other electronic components. Several hardware options, such as the microprocessors and memory,
are installed directly on the system board. Each expansion-card riser accommodates one full-length and one half-length PCIe expansion card.
The system provides space for an optional optical drive. The optical drive connects to the SATA controller on the system board. For more information, see
The hard-drive bays provide space for up to two 2.5-inch SAS or two 2.5-inch SATA hard drives. The hard drives connect to a SAS controller card through the
During an installation or troubleshooting procedure, you may be required to change a jumper setting. For more information, see System Board Jumpers.
Front Bezel
A lock on the bezel restricts access to the power button, optical drive, and hard drive(s). A control panel LCD located on the front panel and accessible through
Figure 3-2. Control Panel LCD With Bezel Installed
1
bezel
2
control panel LCD
Removing the Front Bezel
1. Using the system key, unlock the bezel.
2. Press the tab at the left end of the bezel.
3. Rotate the left end of the bezel away from the system to release the right end of the bezel.
Figure 3-3. Removing the Front Bezel
1
bezel lock
2
bezel
Replacing the Front Bezel
To replace the front bezel, perform the above steps in reverse.
Opening and Closing the System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Opening the System
To upgrade or troubleshoot the system, remove the system cover to gain access to internal components.
1. Unless you are installing a hot-plug component such as a cooling fan or power supply, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet and peripherals.
2. To remove the system cover, turn the latch release lock counter-clockwise to the unlocked position. See Figure 3-4.
4. Grasp the cover on both sides and carefully lift the cover away from the system.
Closing the System
1. Lift up the latch on the cover.
2. Place the cover on top of the system and offset the cover slightly back so that it clears the chassis J hooks and lays flush on the system chassis. See
3. Push down the latch to lever the cover into the closed position.
4. Rotate the latch release lock in a clockwise direction to secure the cover.
Figure 3-4. Removing the Cover
1
3
latch
2
latch release lock
alignment J hooks
Hard Drives
This subsection describes how to install and configure SAS or SATA hard drives in the system's internal hard-drive bays. Your system features up to two 2.5-
inch SAS or SATA hard drives. All drives connect to the system board through the SAS/SATA backplane board. See Figure 6-3. Hard drives are supplied in
special hot-pluggable drive carriers that fit in the hard-drive bays.
NOTICE: Before attempting to remove or install a drive while the system is running, see the documentation for the SAS controller daughter card to
ensure that the host adapter is configured correctly to support hot-plug drive removal and insertion.
NOTE: All installed drives must be either SAS or SATA. Mixed drive configurations are not supported.
NOTE: It is recommended that you use only drives that have been tested and approved for use with the SAS/SATA backplane board.
You may need to use different programs than those provided with the operating system to partition and format SAS or SATA hard drives.
NOTICE: Do not turn off or reboot your system while the drive is being formatted. Doing so can cause a drive failure.
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to
format.
Removing a Drive Blank
NOTICE: To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed. If you remove a hard-drive carrier from the
system and do not reinstall it, you must replace the carrier with a drive blank.
Remove the drive blank as you would the 2.5-inch hard drive carrier:
3. Slide the drive blank out until it is free of the drive bay.
Installing a Drive Blank
Install the hard drive blank as you would a 2.5-inch hard drive carrier:
2. Open the handle on the drive blank.
3. Insert the drive blank into the drive bay until the blank is fully seated.
4. Close the handle to lock the blank in place.
Removing a Hot-Plug Hard Drive
2. From the RAID management software, prepare the drive for removal and wait until the hard-drive indicators on the drive carrier signal that the drive can
be removed safely. See your SAS controller documentation for information about hot-plug drive removal.
If the drive has been online, the green activity/fault indicator will flash as the drive is powered down. When both drive indicators are off, the drive is
ready for removal.
4. Slide the hard drive out until it is free of the drive bay.
5. If you do not replace the hard drive, insert a drive blank in the vacated drive bay. See Installing a Drive Blank.
NOTICE: To maintain proper system cooling, all empty hard-drive bays must have drive blanks installed.
Installing a Hot-Plug Hard Drive
NOTICE: When installing a hard drive, ensure that the adjacent drives are fully installed. Inserting a hard-drive carrier and attempting to lock its handle
next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable.
NOTICE: Not all operating systems support hot-plug drive installation. See the documentation supplied with your operating system.
Figure 3-5. Installing a Hot-Plug Hard Drive
1
3
hard drive
2
drive carrier
drive carrier release handle
3. Install the hot-plug hard drive.
a. Open the handle on the hard-drive carrier.
b. Insert the hard-drive carrier into the drive bay until the carrier contacts the backplane.
c. Close the handle to lock the drive in place.
Replacing a Hard-Drive Carrier
Two versions of hard-drive carriers are used with your system. The version for SATA hard drives has a single set of (four) mounting holes on the side rails. The
second version, called a SAS/SATAu hard-drive carrier, has an extra four mounting holes to enable either a "SAS" and "SATAu" mounting position. When using
the SAS/SATAu hard-drive carrier, observe these rules with regard to your system:
l
l
Use only SAS hard drives with SAS/SATAu drive carriers.
Use only the "SAS" mounting position on the carrier. (The SATAu position is reserved.)
Removing a Hard Drive From a Hard-Drive Carrier
Remove the four screws from the slide rails on the hard-drive carrier and separate the hard drive from the carrier.
Installing a Hard Drive Into a Drive Carrier
1. Insert the hard drive into the hard-drive carrier with the connector end of the drive at the rear. See Figure 3-6.
2. Viewing the assembly as shown in Figure 3-6, align the screw holes on the hard drive with the rear set of holes on the hard drive carrier.
When aligned correctly, the rear of the hard drive will be flush with the rear of the hard-drive carrier.
Figure 3-6. Installing a SAS Hard Drive Into a SAS/SATAu Drive Carrier
1
3
screws (4)
hard drive
2
drive carrier
Power Supplies
Your system supports one or two power supplies rated at an output of 700 W. If only one power supply is installed, it must be installed in the left power
supply bay (PS1). If two power supplies are installed, the second power supply provides hot-pluggable power redundancy. In redundant mode, the system
distributes the power load across both power supplies to maximize efficiency. When a power supply is removed with the system powered on, the full power
load is picked up by the remaining power supply.
NOTICE: To ensure proper system cooling, the power supply blank must be installed on the unoccupied power supply bay in a non-redundant
Removing a Power Supply
NOTICE: The system requires one power supply to operate the system normally. On power-redundant systems, remove and replace only one power
supply at a time in a system that is powered on.
NOTE: On your rack system, you may have to unlatch and lift the optional cable management arm if it interferes with power supply removal. For
information about the cable management arm, see the system's Rack Installation Guide.
1. If your system has a single power supply, turn off the system and all attached peripherals. For a redundant system, you can leave the system running
and proceed to the next step.
2. Disconnect the power cable from the power source.
3. Disconnect the power cable from the power supply and remove the cable from the cable retention bracket.
4. Release the locking tab on the left side of the power supply by pressing in toward the right, and rotate the power-supply handle up until the power
5. Pull the power supply straight out to clear the chassis.
Figure 3-7. Removing and Installing a Power Supply
1
locking tab
2
cable retention bracket
3
power-supply handle
Replacing a Power Supply
1. With the power-supply handle in the extended position, slide the new power supply into the chassis. See Figure 3-7.
2. Rotate the handle down until it is completely flush with the power-supply faceplate and the orange snap engages. See Figure 3-7.
3. Connect the power cable to the power supply.
a. Route the power cable into the cable retention bracket from the power supply side of the bracket (see Figure 3-7).
b. Loop the cable from the cable retention bracket up to the power plug at the back of the power supply, and connect the cable.
c. Plug the other end of the cable into a power distribution unit (PDU) or power outlet.
NOTE: After installing a new power supply, allow several seconds for the system to recognize the power supply and determine whether it is working
properly. The power supply status indicator will turn green to signify that the power supply is functioning properly. See Figure 1-4.
Removing the Power Supply Blank
If you are installing a second power supply, remove the power supply blank in the bay by pulling outward on the blank handle, rotate the blank slightly to
clear the bay, and remove from the chassis.
NOTICE: To ensure proper system cooling, the power supply blank must be installed in the second power supply bay in a non-redundant configuration.
Remove the power supply blank only if you are installing a second power supply.
Installing the Power Supply Blank
NOTE: Install the power supply blank only in the second power supply bay.
To install the power supply blank, insert the tab on the right edge of the blank into the slot in the power supply bay wall. Rotate the blank into the power
supply bay.
Internal SD Card
The system provides a slot on top of the expansion-card riser 1 for an internal SD card.
NOTE: To use an SD card with your system, ensure that the SD card port is enabled in the System Setup program. See Using the System Setup
Removing the SD Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Locate the SD card at the top of riser 1, push down on the card to release it, and pull the card from the card slot. See Figure 3-8.
Figure 3-8. Removing or Installing an Internal SD Card
1
3
riser 1
2
SD card slot (SD connector)
SD card
Installing the SD Card
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Locate the SD card slot at the top of riser 1 and insert the contact-pin end of the card into the slot with the label on the card facing outward from the
NOTE: The slot is keyed to ensure correct insertion of the card.
4. Press down on the card to lock it into the slot.
System Fans
The system includes six hot-pluggable fans to provide cooling to the system's interior components. Fans 1 through 4, located behind the optical drive and SAS
backplane, provide airflow over the processors and the "B" memory modules. Fans 5 and 6, located near the power supply bays, draw air over the "A" memory
Removing a System Fan
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTICE: The system fans are hot-pluggable. To maintain proper cooling while the system is on, replace only one fan at a time.
Use caution when handling the fan until the fan blades stop spinning.
2. Raise the fan handle and pull the fan straight up from the fan bracket to clear the chassis. See Figure 3-9.
Figure 3-9. Removing and Installing a Cooling Fan
1
3
fan 1
2
4
fan 4
fan release handle
fan bracket
Replacing a Cooling Fan
1. Ensure that the fan handle is upright and lower the fan into its fan bracket until the fan is fully seated. Then lower the fan handle until it snaps into
SAS Controller Daughter Card
Your system includes a dedicated slot on the sideplane for an internal SAS controller daughter card that provides the SAS storage subsystem for your system's
internal hard drives. The controller supports either all-SAS or all-SATA hard drive configurations and also enables you to set up the hard drives in RAID
configurations as supported by the version of the SAS controller included with your system.
Installing a SAS Controller Daughter Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Place the SAS daughter card tray on the SAS card bay on top of the hard drive bay and align the card connector with the slot on the sideplane board.
4. With the hooks on the SAS card bay inserted into the cutouts on the SAS daughter card tray, push the card edge connector into the card slot on the
Figure 3-10. Installing a SAS Controller Daughter Card
1
3
5
7
SAS controller daughter card
2
4
6
8
sideplane
SAS controller daughter card socket
RAID battery connector (battery-cached SAS RAID controller only)
SAS cable (1)
release tab
cutout
SAS connector(s) (1 or 2) (only SAS 0 used)
5. Attach one end of the interface cable to connector 0 on the SAS controller and the other end to the backplane SAS connector. See Figure 3-11.
NOTE: Be sure to connect the cable according to the connector labels on the cable. The cable is not operational if reversed.
Figure 3-11. SAS Controller Daughter Card Cabling
1
3
SAS controller daughter card
2
4
SAS 0 connector
SAS cable (1)
SAS_A connector (below BKPLN connector)
6. For battery-cached SAS RAID controllers, install the RAID battery. See Installing a RAID Battery.
Removing a SAS Controller Daughter Card
1. Disconnect the SAS cable from the SAS controller daughter card.
2. Press down on the blue release tab and push the SAS controller daughter card out of the sideplane connector. See Figure 3-10.
3. Remove the card tray from the chassis hooks and lift the card from the system.
4. If applicable, remove the RAID battery from the battery holder.
RAID Battery
The information in this section applies only to systems with the optional battery-cached SAS controller daughter card.
Installing a RAID Battery
2. Locate the battery bay to the right of the SAS daughter card on top of the hard drive bays.
3. Insert the battery carrier and RAID battery into the system's battery carrier slots and connect the battery cable to the storage daughter card, ensuring
that the battery carrier is aligned and fully seated in the slots.
Removing a RAID Battery
1. Disconnect the cable between the RAID battery and the SAS controller daughter card. See Figure 3-12.
2. Press down and to the left on the battery carrier to disengage the carrier from the chassis battery carrier slots.
3. Pull back gently on the two guides holding the RAID battery in the battery carrier and draw out the RAID battery from the battery carrier.
Figure 3-12. Installing a RAID Battery
1
3
RAID battery connector (RAID_BATT)
RAID battery
2
4
battery carrier
chassis battery carrier slot (2)
Configuring the Boot Device
NOTE: System boot is not supported from an external device attached to a SAS or SCSI adapter. See support.dell.com for the latest support
information about booting from external devices.
If you plan to boot the system from a hard drive, the drive must be attached to the primary (or boot) controller. The device that the system boots from is
determined by the boot order specified in the System Setup program.
The System Setup program provides options that the system uses to scan for installed boot devices. See Using the System Setup Program for information
about the System Setup program.
Internal USB Memory Key Connector
The system provides an internal USB connector located on the expansion-card riser 2 board for use with a USB flash memory key (see Figure 6-4). The USB
memory key can be used as a boot device, security key, or mass storage device. To use the internal USB connector, the Internal USB Port option must be
enabled in the Integrated Devices screen of the System Setup program.
To boot from the USB memory key, you must configure the USB memory key with a boot image and then specify the USB memory key in the boot sequence in
the System Setup program. See System Setup Options. For information on creating a bootable file on the USB memory key, see the user documentation that
accompanied the USB memory key.
Installing the Optional Internal USB Memory Key
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
If you have full-length expansion card in slot 3, you may have to remove the card to install the USB key. See Removing an Expansion Card.
7. Reconnect the system to power and restart the system.
8. Enter the System Setup program and verify that the USB key has been detected by the system. See Using the System Setup Program.
Figure 3-13. Installing an Internal USB Key
1
3
USB memory key
2
internal USB connector
expansion-card riser 2
Expansion Cards
The system supports up to four PCI Express (PCIe) expansion cards.
l
Expansion-card riser 1 provides two slots:
¡
¡
Slot 1 is a full-length PCIe x8-lane expansion slot.
Slot 2 is a half-length PCIe x4-lane expansion slot.
l
Expansion-card riser 2 provides two slots:
¡
¡
Slot 3 is a full-length PCIe x8-lane expansion slot.
Slot 4 is a half-length PCIe x8-lane expansion slot.
The expansion card slots are on separate buses. To identify expansion slots, see Expansion-Card Riser-Board Components and PCIe Buses.
Expansion Card Installation Guidelines
Observe the following notes and guidelines regarding the expansion-card slots:
l
l
l
l
The expansion-card slots are not hot-pluggable.
Although slot 2 is physically a PCIe x8 connector, it functions only as a PCIe x4 lane slot.
Slots 1 and 3 support full-length expansion cards; slots 2 and 4 support half-length expansion cards.
The system supports up to two RAID expansion cards to manage external storage.
Installing an Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE: The procedure for installing expansion cards into risers 1 and 2 is the same except that slot 3 on riser 2 has a card guide for installing a full-
1. Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
4. Open the expansion-card guide latch and remove the filler bracket at the back of the system. See Figure 3-14.
5. Install the expansion card:
a. If the expansion card is full length, align its front edge with the front card guide. See Figure 3-14.
b. Position the expansion card so that the card-edge connector aligns with the expansion-card connector on the expansion-card riser board.
c. Insert the card-edge connector firmly into the PCIe card connector until the card is fully seated.
6. Connect any expansion-card cables for the new card.
See the documentation that came with the card for information about its cable connections.
Removing an Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Disconnect any cables connected to the expansion card.
Figure 3-14. Removing or Installing an Expansion Card
1
3
5
front card guide
2
4
expansion card
expansion-card connector
expansion-card guide latch
card-edge connector
4. Remove the expansion card:
b. Grasp the expansion card by its top corners, and carefully pull the card from the expansion-card connector.
5. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.
NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications Commission (FCC) certification of the
system. The brackets also aid in proper cooling and airflow inside the system.
Cooling Shrouds
The system provides three cooling shrouds that direct airflow from the cooling fans over the system processors (processor cooling shroud) and memory
modules (memory module cooling shrouds "A" and "B").
CAUTION: The DIMMs are hot to the touch for some time after the system has been powered down. Allow the DIMMs to cool before handling
them.
NOTICE: Never operate your system with the memory cooling shroud removed. Overheating of the system can develop quickly resulting in a shutdown
of the system and the loss of data.
Removing the Memory Module Cooling Shrouds
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Squeeze the blue release latches located on top of the memory module cooling shroud and lift the shroud out of the system. See Figure 3-15.
4. Repeat the previous step for the other memory module cooling shroud.
Figure 3-15. Removing and Installing the Cooling Shrouds
1
3
5
7
pin collar (2)
2
4
6
8
processor cooling shroud
release tabs
memory module cooling shroud ("A")
memory module cooling shroud ("B")
mounting pins (6)
pin collar (2)
mounting pins on fan brackets (2)
Removing the Processor Cooling Shroud
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Detach and remove the two memory module cooling shrouds on each side of the processor cooling shroud.
Installing the Processor Cooling Shroud
1. Align the pin collars at the bottom of the processor cooling shroud with the pins located on the two fan brackets. See Figure 3-15.
2. Lower the processor cooling shroud straight down onto the pins.
Installing the Memory Module Cooling Shrouds
1. Align the pin collars at the bottom of the right ("B") memory module cooling shroud with the pins located on the right side of the "B" memory module
2. Lower the shroud straight down onto the pins and press down lightly to latch the shroud to the processor cooling shroud.
3. Lower the left ("A") memory module shroud over the "A" memory modules and press down lightly to latch the shroud to the processor cooling shroud.
5. Reconnect the system to the electrical outlet and turn on the system and attached peripherals.
Fan Brackets
Removing the Fan Brackets
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
7. For the processor fan bracket only: Remove the SAS controller daughter card. See Removing a SAS Controller Daughter Card.
8. Remove the fan bracket from the system:
b. Slide the fan bracket toward the release latch to disengage from the system board tray. See Figure 3-16.
c. Lift the bracket out of the system.
Figure 3-16. Removing and Installing the Processor Fan Bracket
1
release latch
2
fan bracket
Replacing the Fan Bracket
1. Lower the fan bracket down onto the bracket base so that the tabs and hooks under the bracket fit correctly into the bracket base. See Figure 3-16.
2. With the bracket properly engaged, slide the bracket to lock it in place.
7. If applicable, reinstall the SAS controller daughter card. See Installing a SAS Controller Daughter Card.
Expansion-Card Risers
Removing Expansion-Card Riser 1
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE: You must remove all expansion cards from the expansion-card riser before removing the riser from the system.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Disconnect all cables connected to the expansion card.
5. Press the tab at the bottom of the riser to release the board from the card slot and lift expansion-card riser 1 off of the mounting pins and out of the
Replacing Expansion-Card Riser 1
Aligning the two pin collars over the mounting pins on the system board, gently lower the center riser board until the board connector is firmly seated into the
Figure 3-17. Removing and Replacing Expansion-Card Riser 1
1
3
5
pin collars (2)
2
4
release tab
expansion-card riser 1
system board socket
mounting pins (2)
Removing Expansion-Card Riser 2
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTE: You must remove all expansion cards from the expansion-card riser before removing the riser from the system.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Disconnect all cables connected to the expansion card.
5. Press the two blue release latches on expansion-card riser 2 and lift the riser straight up to clear the chassis. See Figure 3-18.
Replacing Expansion-Card Riser 2
1. Align the guides on each end of expansion-card riser 2 with the mounting pins on the system board, and lower the riser into the system until the latches
2. Reinstall any expansion cards.
3. Reconnect all expansion-card cables.
Figure 3-18. Removing and Replacing Expansion-Card Riser 2
1
3
expansion-card riser 2
pin collars (2)
2
4
release latches (2)
mounting pins (2)
Removing the Riser 2 Board From the Expansion-Card Bracket
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
Figure 3-19. Removing and Replacing the Riser 2 Board
1
3
5
expansion-card bracket
Phillips screw
2
4
riser 2 board
tab slot (4)
tab hook (4)
5. Remove the expansion-card riser board:
b. Slide the riser board off of the four securing tab hooks.
c. Lift the riser board from the bracket.
Replacing the Riser 2 Board on the Expansion-Card Bracket
1. Place the riser board in the expansion-card bracket so that the four tab hooks are fully inserted through the tab slots on the riser board. See Figure 3-
2. Slide the riser board into the tab hooks.
3. Using a Phillips screwdriver, secure the board with the Phillips screw.
RAC Card
The optional Remote Access Controller (RAC) provides a set of advanced features for managing the server remotely.
Removing the RAC Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
Figure 3-20. Removing and Installing a RAC Card
1
3
5
7
standoff holes (2)
RAC-card cables (2)
support standoff
2
4
6
RAC-card connectors (2)
RAC card
cutout
retention standoffs (2)
6. Pull back slightly on one of the blue retention standoff tabs and gently work the edge of RAC card off of the standoff. Repeat for the other retention
standoff.
7. Angle the free end of the RAC card up and pull the card away from the support standoff.
8. If you are not replacing the RAC card, disconnect and remove the ribbon cables from the system board and insert the plastic filler plug in the system
back panel.
NOTICE: When detaching the RAC cables from the system board, squeeze the metal ends of the cable connectors and gently work the connector out of
the socket. Do not pull on the cable to unseat the connector. Doing so can damage the cable.
Installing a RAC Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
5. If you are installing a RAC card for the first time, remove the plastic filler plug from the system back panel. See Figure 3-20.
6. Angle the RAC card so that its NIC connector inserts through the back- panel RAC card opening, and then straighten the card.
7. Position the back edge of the card so that the cutout on the edge of the card inserts into the support standoff. See Figure 3-20.
When the front of the card is fully seated, the plastic standoff snaps over the edge of the card.
9. Connect the two short ribbon cables to the RAC card and the system board. See Figure 6-2 for the connector locations
NOTICE: Be careful when attaching cables to the system board that you do not damage the surrounding system board components.
a. Connect one cable to connector 1 on the RAC card and to RAC_CONN1 on the system board.
b. Connect the second cable to connector 2 on the RAC card and to RAC_CONN2 on the system board.
See the RAC card documentation for information on configuring and using the RAC card.
LOM Daughter Card
The LAN-on-motherboard (LOM) NIC daughter card provides two additional NIC LOMs. The two daughter card LOMs are upgradeable to 10Gbps data rate
capability, when available.
Removing the LOM Daughter Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
Figure 3-21. Installing and Removing a LOM Daughter Card
1
3
5
retention standoff (2)
retention standoff holes (2)
support standoff
2
4
6
LOM daughter card connector
LOM daughter card
cutout
4. Pull back slightly on the two blue retention standoff tabs at the front edge of the card and gently work the edge of LOM card off of the standoffs.
As the card releases from the standoffs, the connector under the LOM card disengages from the system board.
5. Slide the card back to release the back edge of the card from the two support standoffs and lift the card out of the system.
Replacing the LOM Daughter Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Angle the LOM card so that its NIC connectors are positioned toward the back-panel LOM card opening.
2. Straighten the card so that the cutouts on the side edges of the card insert into the two support standoffs. See Figure 3-21.
3. Slide the card back slightly and align the front edge of the LOM card with the two front plastic retention standoffs adjacent to the LOM system board
When the front of the card is fully seated, the plastic standoff snaps over the edge of the card.
Optical Drive
An optional slimline DVD or CD-RW/DVD-RW optical drive is mounted on a tray that slides in the front panel and connects to the controller on the system board.
NOTE: DVD devices are data only.
Removing the Optical Drive from the System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
3. Disconnect the optical drive cable from the back of the optical drive tray.
4. To remove the optical drive, pull up on the blue release tab at the back of the optical drive tray and push the tray out of the system. See Figure 3-24.
Installing the Optical Drive
2. Slide in the drive tray until the tray snaps into place.
3. Connect the optical drive cable to the back of the drive tray.
4. If not already done, connect the power and interface cables from the optical drive to the SAS/SATA backplane and system board connectors.
a. Connect the power cable to the CD_PWR connector on the backplane board. See Figure 6-3 for the location of the connector and Figure 3-22 for
the routing of the cable.
b. Route the interface cable along the inside right chassis side panel, inserting the cable under each of the cable routing tabs. See Figure 3-23.
c. Connect the cable to the SATA_A connector on the system board. See Figure 6-2 for the location of the connector.
7. Reconnect your system and peripherals to their electrical outlets, and turn on the system.
Figure 3-22. Removing and Installing the Optical Drive Tray
1
3
5
optical drive
2
4
optical-drive interface cable
optical-drive release tab
power cable
optical-drive tray
Figure 3-23. Cabling the Optical Drive
1
3
5
SATA connector (SATA_A) on system board
routing tabs in chassis side wall
optical drive power cable
2
4
6
SATA interface cable
optical-drive SATA connector
CD_PWR connector on backplane
Removing the Optical Drive From the Optical Drive Tray
Pull outward on the tab at the back of the carrier on the left side and simultaneously pull up on the left side of the optical drive to separate the drive from the
Figure 3-24. Removing and Installing the Optical Drive in the Optical Drive Carrier
1
optical drive
2
optical drive carrier
Installing an Optical Drive Into the Optical Drive Tray
1. With the optical drive at a slight angle to the drive tray, lower the right side of the optical drive down onto the right side of the drive tray. See Figure 3-
2. Lower the left side of the optical drive and press the drive down into the tray until it snaps into place.
System Memory
You can upgrade your system memory to a maximum of 128 GB by installing 667-MHz registered parity DDR2 memory modules (DIMMs) in sets of 512-MB, 1-GB,
2-GB, 4-GB, or 8-GB single- or dual-ranked modules (quad-ranked modules are not supported). The memory sockets are located on the system board under
the memory module cooling shrouds and are split into two separate groups of eight sockets each. Each eight-socket group is adjacent to its respective
processor.
Your system hardware supports Non-Uniform Memory Architecture (NUMA). Each processor has its own memory controller and local memory for reduced access
times, but it can also access memory from another processor. This architecture improves system performance if an operating system is installed that supports
this feature.
NOTICE: To enable NUMA, run the System Setup program and disable the Node Interleaving option. See Using the System Setup Program.
General Memory Module Installation Guidelines
To ensure optimal performance of your system, observe the following guidelines when configuring your system memory.
l
l
Memory must be installed in configurations of four, eight, or sixteen DIMMs. The minimum configuration is four 512-MB DIMMs.
DIMMs must be installed in matched sets of identical speed, technology, and size in the following sockets:
¡
¡
¡
A1, A2, B1, and B2 — four identical DIMMs in this set
A3, A4, B3, and B4 — four identical DIMMs in this set
A5 through A8 and B5 through B8 — eight identical DIMMs in this set
l
l
Minimum configurations (four DIMMs) must occupy sockets A1, A2, B1, and B2.
A matched DIMM set can be mixed with another matched DIMM set of the next smaller size. For example, a DIMM set containing 2-GB DIMMs can be
mixed with another DIMM set containing 1-GB DIMMs, but not a set containing 512-MB DIMMs. The larger capacity DIMMs must occupy the lower-
numbered DIMM sockets.
Table 3-1. Memory Configurations
DIMM Sets (Size Per Socket)
Total Memory
DIMM Set
DIMM Set
DIMM Set
A1, A2, B1, B2 A3, A4, B3, B4 A5, A6, A7, A8, B5, B6, B7, B8
2 GB
4 GB
8 GB
4 GB
6 GB
8 GB
12 GB
16 GB
512 MB
512 MB
512 MB
1 GB
512 MB
512 MB
512 MB
1 GB
512 MB
1 GB
1 GB
1 GB
1 GB
512 MB
1 GB
1 GB
1 GB
8 GB
2 GB
2 GB
2 GB
2 GB
2 GB
4 GB
4 GB
4 GB
4 GB
4 GB
8 GB
8 GB
8 GB
8 GB
8 GB
12 GB
16 GB
24 GB
32 GB
16 GB
24 GB
32 GB
48 GB
64 GB
32 GB
48 GB
64 GB
96 GB
128 GB
1 GB
2 GB
2 GB
2 GB
1 GB
2 GB
2 GB
4 GB
4 GB
4 GB
2 GB
4 GB
4 GB
8 GB
8 GB
8 GB
4 GB
8 GB
Memory Sparing Support
Memory sparing is supported in systems that have one of the fully populated memory configurations shown in Table 3-1. The memory sparing feature must be
enabled in the Memory Information screen of the System Setup program. See Using the System Setup Program.
NOTE: The Memory sparing and node interleaving features cannot be used at the same time. To use memory sparing, you must disable the Node
Interleaving option in the System Setup program.
Memory sparing is applied independently to the two groups of DIMMs on opposite sides of the processor sockets. To support memory sparing, all DIMM
sockets within a DIMM group must be populated.
When enabled, memory sparing allocates and reserves ranks of memory from the installed DIMMs to act as spare memory in the event of a memory channel
failure. A memory channel uses paired DIMMs; for memory sparing to work, DIMMs must be paired as spares also.
Memory sparing allocates only the first rank of memory of a DIMM. For a single-rank DIMM, the entire capacity of the DIMM must be allocated for sparing along
with the adjacent single-rank DIMM to spare a memory channel. For dual-rank DIMMs, two DIMMs are also required for sparing, but as only the first rank of
each DIMM is allocated, only half of a dual-rank DIMM's capacity is allocated for sparing. The second ranks on both DIMMs are available memory.
Memory sparing calculates the appropriate DIMMs to spare by searching the DIMM sockets, starting with the higher-numbered socket pair (specifically, sockets
3 and 4 or sockets 7 and 8), for an amount of memory large enough to spare one of the available channels of memory. If the DIMMs in these sockets are
sufficient to spare a channel of the available memory, the first rank of each of those two DIMMs are spared. If the amount of memory is not large enough to
spare an available memory channel, the system spares the DIMM ranks in the lower-numbered sockets. Table 3-2 shows how memory sparing works in
various memory configurations.
Table 3-2. Memory Sparing Configurations
DIMMs
Available Memory
Spared
Memory
A1, A2, B1, B2
A3, A4, B3, B4
512 MB
A5, A6, B5, B6
512 MB
A7, A8, B7, B8
512 MB
512 MB
1 GB
6 GB
2 GB
4 GB
4 GB
8 GB
16 GB
1 GB
2 GB
4 GB
8 GB
1 GB
2 GB
4 GB
8 GB
1 GB
2 GB
4 GB
8 GB
12 GB
28 GB
56 GB
112 GB
2 GB
4 GB
8 GB
Indicates a spared single-rank DIMM (512-MB or 1-GB). The entire capacity of this DIMM is reserved for sparing.
Indicates a spared dual-rank DIMM (2-GB and higher). One-half of this DIMM's capacity is reserved for sparing.
Installing Memory Modules
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
NOTICE: Never remove the memory cooling shroud without first powering down the system. Overheating of the system can develop quickly resulting in
a shutdown of the system and the loss of data.
CAUTION: The DIMMs are hot to the touch for some time after the system has been powered down. Allow time for the DIMMs to cool before
handling them. Handle the DIMMs by the card edges and avoid touching the DIMM components.
5. Press the ejectors on the memory module socket down and out, as shown in Figure 3-25, to allow the memory module to be inserted into the socket.
6. Align the memory module's edge connector with the alignment key on the memory module socket, and insert the memory module in the socket.
NOTE: The memory module socket has two alignment keys that allows you to install the memory module in the socket in only one way.
Figure 3-25. Installing and Removing a Memory Module
1
3
memory module
socket
2
4
memory module socket ejectors (2)
alignment keys (2)
7. Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the socket.
When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that
have memory modules installed.
NOTICE: Never operate your system with the memory cooling shroud removed. Overheating of the system can develop quickly resulting in a shutdown
of the system and the loss of data.
11. (Optional) Enter the System Setup program, and check the System Memory setting on the main System Setup screen. See Entering the System Setup
The system should have already changed the value to reflect the newly installed memory.
12. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 2 through step 11 of this procedure, checking to
ensure that the memory modules are firmly seated in their sockets.
Removing Memory Modules
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
NOTICE: Never remove the memory cooling shroud without first powering down the system. Overheating of the system can develop quickly resulting in
a shutdown of the system and the loss of data.
CAUTION: The DIMMs are hot to the touch for some time after the system has been powered down. Allow the DIMMs to cool before handling
them. Handle the DIMMs by the card edges, and avoid touching the DIMM components.
5. Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 3-25.
NOTICE: Never operate your system with the memory cooling shroud removed. Overheating of the system can develop quickly resulting in a shutdown
of the system and the loss of data.
Integrated NIC TOE
The TCP/IP Offload Engine (TOE) functionality of the system's integrated NIC is activated by the LOM NIC hardware key installed in the TOE_KEY socket on the
system board (see Figure 6-2.) See the user documentation that came with this system for information on how to set up and configure the TOE feature.
Processors
You can upgrade your processors to take advantage of future options in speed and functionality. Each processor and its associated internal cache memory are
contained in a land grid array (LGA) package that is installed in a ZIF socket on the system board.
Removing a Processor
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Prior to upgrading your system, download the latest system BIOS version on support.dell.com.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
NOTICE: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper
thermal conditions.
8. Using a #2 Phillips screwdriver, loosen one of the two heat-sink retention screws. See Figure 3-26.
9. Wait 30 seconds for the heat sink to loosen from the processor.
10. Loosen the other heat-sink retention screw.
11. Gently lift the heat sink off of the processor and set the heat sink aside.
NOTICE: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped.
12. Position your thumb firmly over the socket-release lever and release the lever from the locked position. Rotate the lever 90 degrees upward until the
Figure 3-26. Installing and Removing the Heat Sink
1
heat sink
2
heat-sink retention screws (2)
13. Rotate the processor shield upward and out of the way.
14. Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor.
NOTICE: Be careful not to bend any of the pins on the ZIF socket when removing the processor. Bending the pins can permanently damage the system
board.
Figure 3-27. Installing and Removing a Processor
1
3
5
notch in processor (2)
socket-release lever
processor shield
2
4
6
processor
ZIF socket
socket key (2)
Installing a Processor
1. Unpack the new processor.
3. Install the processor in the socket.
NOTICE: Positioning the processor incorrectly can permanently damage the system board or the processor when you turn it on. When placing the
processor in the socket, be careful not to bend the pins in the socket. Avoid touching the socket pins or the pads on the processor when handling the
processor or the system board.
a. If the release lever on the processor socket is not positioned all the way up, move it to that position.
b. With the processor and the socket keys aligned, set the processor lightly in the socket.
NOTICE: Do not use force to seat the processor. When the processor is positioned correctly, it engages easily into the socket.
d. When the processor is fully seated in the socket, rotate the socket release lever back down until it snaps into place, securing the processor. See
4. Install the heat sink.
a. Using a clean lint-free cloth, remove the thermal grease from the heat sink removed from the old processor.
b. Open the grease packet included with your processor kit and apply thermal grease evenly to the top of the new processor.
As the system boots, it detects the presence of the new processor and automatically changes the system configuration information in the System Setup
program.
10. Press <F2> to enter the System Setup program, and check that the processor information matches the new system configuration. See Entering the
11. Run the system diagnostics to verify that the new processor operates correctly.
System Battery
The system battery is a 3.0-volt (V), coin-cell battery.
Replacing the System Battery
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type
recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. See your System Information Guide for
additional information.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
Figure 3-28. Replacing the System Battery
1
3
positive side of battery connector
negative side of battery connector
2
system battery
NOTICE: If you pry the battery out of its socket with a blunt object, be careful not to touch the system board with the object. Ensure that the object is
inserted between the battery and the socket before you attempt to pry out the battery. Otherwise, you may damage the system board by prying off
the socket or by breaking circuit traces on the system board.
NOTICE: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.
4. Remove the system battery.
a. Support the battery connector by pressing down firmly on the positive side of the connector.
b. While supporting the battery connector, press the battery toward the positive side of the connector and pry it up out of the securing tabs at the
negative side of the connector.
NOTICE: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery.
5. Install the new system battery.
a. Support the battery connector by pressing down firmly on the positive side of the connector.
b. Hold the battery with the "+" facing up, and slide it under the securing tabs at the positive side of the connector.
c. Press the battery straight down into the connector until it snaps into place.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
8. Enter the System Setup program to confirm that the battery is operating properly. See Entering the System Setup Program.
9. Enter the correct time and date in the System Setup program's Time and Date fields.
10. Exit the System Setup program.
11. To test the newly installed battery, turn off the system and disconnect it from the electrical outlet for at least an hour.
12. After an hour, reconnect the system to its electrical outlet and turn it on.
13. Enter the System Setup program and if the time and date are still incorrect, see Getting Help for instructions on obtaining technical assistance.
Sideplane Board
Removing the Sideplane Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
4. Remove any cables from the sideplane board.
NOTICE: When detaching the control panel cable from the sideplane board, squeeze the metal ends of the cable connectors and gently work the
connector out of the socket. Do not pull on the cable to unseat the connector. Doing so can damage the cable.
5. Pressing inward on the sideplane release tabs, lift the sideplane up and away from the system. See Figure 3-29
Installing the Sideplane Board
1. Insert the sideplane board into sideplane slots along the left wall of the chassis and lower the sideplane board so that the pin collars connect with the
two pins on the system board. Press the sideplane down until sideplane connector is fully seated into the system board connector. See Figure 3-29.
2. Reattach the control panel cable to the sideplane board.
Figure 3-29. Sideplane Removal and Installation
1
3
5
7
9
sideplane
2
4
6
8
control panel connector
sideplane release tab (2)
chassis pin (2)
control panel cable
pin collar (2)
sideplane connector
SAS controller daughter card
system board
10 SAS controller daughter card release handle
11 SAS controller daughter card socket
SAS/SATA Backplane Board
Removing the SAS/SATA Backplane Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. If present, disconnect the optical drive power cable from the SAS/SATA backplane board. See Removing the Optical Drive from the System.
4. Open the drive-carrier release handle on each hard drive and partially extend the drive(s) out of their drive bays. See Removing a Hot-Plug Hard Drive.
6. Disconnect the SAS cable from the backplane connector.
7. Disconnect the power cable from the backplane connector.
8. Disconnect the optical drive power cable from the backplane connector.
10. Remove the SAS/SATA backplane board:
b. While pulling the release pin, tilt the backplane board toward the back of the system.
c. Lift the backplane board from its securing tabs and remove the backplane board from the chassis.
Figure 3-30. SAS/SATA Backplane Board Removal
1
3
5
7
drive carrier
2
4
6
SAS backplane board release pin
power cable from system board
securing slots (7)
SAS/SATA backplane board
optical drive power connector
securing tabs (7)
Installing the SAS/SATA Backplane Board
1. Position the SAS/SATA backplane board so that the securing tabs on the chassis are fully inserted into the securing slots on the backplane board. See
2. Pull and hold the release pin, and then tilt the backplane board toward the front of the system until it stops, then release the release pin and ensure
that it snaps into place.
4. Reconnect the power cable to the backplane board.
5. If applicable, reconnect the optical drive power cable to the backplane board. See Installing the Optical Drive.
7. Reattach the SAS controller daughter card cable.
NOTE: Reinstall the hard drives in the same drive bays from which they were removed.
Control Panel Assembly
NOTE: The control panel assembly consists of two separate modules—the display module and the control panel circuit board. Use the following
instructions to remove and install either module.
Removing the Control Panel Assembly
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals.
NOTICE: Do not pull on the cable to unseat the connector. Doing so can damage the cable.
a. Squeeze the metal tabs on the ends of the cable connector.
b. Gently work the connector out of the socket.
Figure 3-31. Control Panel Removal
1
3
5
7
display module label
display module
2
4
6
display module securing screws (2)
display module cable
control panel cable
control panel circuit board
control-panel circuit board securing screws (3)
6. Remove the three screws that secure the control panel board to the system chassis and remove the board. See Figure 3-31.
7. Remove the display module:
a. Insert the end of paper clip into the hole on the right side of the display module and gently pry off the label.
b. Using a T10 Torx driver, remove the two screws that secure the display module to the system chassis.
c. Remove the display module from the chassis cutout.
Installing the Control Panel Assembly
1. Insert the display module into the chassis cutout and secure with the two Torx screws.
2. Affix the display module label to the display module.
3. Install the control panel board in the system chassis and secure with the three Phillips screws. See Figure 3-31.
7. Reconnect the system to the power source and turn on the system and attached peripherals.
8. If applicable, install the bezel.
System Board
Removing the System Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
CAUTION: The DIMMs are hot to the touch for some time after the system has been powered down. Allow time for the DIMMs to cool before
handling them. Handle the DIMMs by the card edges and avoid touching the DIMM components.
NOTE: While removing the memory modules, record the memory module socket locations to ensure proper installation.
NOTE: If the board is to be returned for repair, remove the protective ZIF socket shields from the new system board and install them over the
processor sockets on the removed system board to prevent damage to the pins during shipping.
13. Remove the LOM NIC hardware key, if present. See Figure 6-2 for the location of the TOE_KEY socket.
16. Remove the system board:
b. While pulling the release pin, slide the system-board tray toward the front of the chassis.
c. Lift up the system-board tray and remove it from the chassis.
Figure 3-32. System Board Removal
1
3
system-board tray riser release pin
system-board tray
2
4
system board
system-board securing tabs
Installing the System Board
1. Lower the system-board tray until the tray sits flat on the bottom of the chassis.
2. Align the back connectors on the system board with the cutouts in the back of the chassis, and ensure the system-board tray is square with the chassis
so that the securing tabs on the chassis fully insert into system- board securing slots. See Figure 3-32.
3. Slide the system-board tray toward the back of the chassis until it locks into position.
6. Reinstall the LOM NIC hardware key, if applicable. See Figure 6-2 for the TOE_KEY socket location.
Jumpers and Connectors
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
This section provides specific information about the system jumpers and describes the connectors on the various boards in the system.
System Board Jumpers
Figure 6-1 shows the location of the configuration jumpers on the system board. Table 6-1 lists the jumper settings.
NOTE: To access the jumpers, you must remove the expansion cards from expansion-card riser 1. See Removing an Expansion Card.
Figure 6-1. System Board Jumpers
Table 6-1. System Board Jumper Settings
Jumper
Setting
Description
The configuration settings are retained at system boot.
NVRAM_CLR
(default)
The configuration settings are cleared at the next system boot. (If the configuration settings become corrupted to the point
where the system will not boot, install the jumper and boot the system. Remove the jumper before restoring the configuration
information.)
PWRD_EN
The password feature is enabled.
(default)
The password feature is disabled.
System Board Connectors
Figure 6-2. System Board Connectors
Table 6-2. System Board Connectors
Connector
Description
1
2
3
4
5
6
7
8
9
RISER2
expansion-card riser 2 connector
MEZ_CONN LOM daughter card
RISER1
Left riser board connector
RAC_CONN2 Remote Access Control (RAC) card 2
RAC_CONN1 Remote Access Control (RAC) card 1
BATTERY
TOE_KEY
SATA_A
B1
System battery
TCP/IP Offload Engine Key
SATA A connector
First memory module slot (processor 2)
Second memory module slot (processor 2)
Third memory module slot (processor 2)
Fourth memory module slot (processor 2)
Fifth memory module slot (processor 2)
Sixth memory module slot (processor 2)
Seventh memory module slot (processor 2)
Eighth memory module slot (processor 2)
System cooling fan
10 B2
11 B3
12 B4
13 B5
14 B6
15 B7
16 B8
17 FAN4
18 CPU2
19 FAN3
20 CPU1
21 FAN2
22 FAN1
Microprocessor 2
System cooling fan
Microprocessor 1
System cooling fan
System cooling fan
23 BACKPLANE Backplane power connector
24 SIDEPLANE Sideplane connector
25 A1
26 A2
27 A3
28 A4
29 A5
30 A6
31 A7
32 A8
33 FAN5
34 FAN6
First memory module slot (processor 1)
Second memory module slot (processor 1)
Third memory module slot (processor 1)
Fourth memory module slot (processor 1)
Fifth memory module slot (processor 1)
Sixth memory module slot (processor 1)
Seventh memory module slot (processor 1)
Eighth memory module slot (processor 1)
System cooling fan
System cooling fan
SAS/SATA Backplane Board Connectors
Figure 6-3. SAS/SATA Backplane Board Components
1
3
5
drive 0 connector
2
4
drive 1 connector
optical drive power (CD_PWR)
SAS connector (SAS)
backplane power (BKPLN)
Sideplane Board Connectors
Figure 6-4. Sideplane Board Connectors
1
3
5
control panel (CTR_PNL)
2
4
SAS controller daughter card (INT_STORAGE)
pin collars (2)
chassis intrusion switch (INTRUSION)
system board connector
Expansion-Card Riser-Board Components and PCIe Buses
Figure 6-5 and Figure 6-6 show the components on the PCIe expansion-card riser boards, including the expansion-card slots and buses.
Figure 6-5. PCIe Expansion-Card Center Riser 1 Components
1
3
internal SD card slot
2
4
slot 1 PCIe - x8 lane width (full-length)
system board connector
slot 2 PCIe - x8 lane width (half-length)
Figure 6-6. PCIe Expansion-Card Riser 2 Components
1
3
5
Phillips screw
2
4
slot 3 PCIe x8 lane width (full-length)
pin collars (2)
slot 4 PCIe x8 lane width (half-length)
system board connector
Disabling a Forgotten Password
The system's software security features include a system password and a setup password, which are discussed in detail in Using the System Setup Program.
The password jumper enables these password features or disables them and clears any password(s) currently in use.
NOTICE: See "Protecting Against Electrostatic Discharge" in the safety instructions in your Product Information Guide.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the jumper plug from the password jumper.
4. Close the system.
5. Reconnect your system and peripherals to their electrical outlets, and turn on the system.
The existing passwords are not disabled (erased) until the system boots with the password jumper plug removed. However, before you assign a new
system and/or setup password, you must install the jumper plug.
NOTE: If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next
time it boots.
6. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
8. Install the jumper plug on the password jumper.
9. Lower the memory module shroud.
10. Close the system.
11. Reconnect your system and peripherals to their electrical outlets, and turn on the system.
12. Assign a new system and/or setup password.
Using the System Setup Program
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
After you set up your system, run the System Setup program to familiarize yourself with your system configuration and optional settings. Record the
information for future reference.
You can use the System Setup program to:
l
l
l
l
Change the system configuration stored in NVRAM after you add, change, or remove hardware
Set or change user-selectable options—for example, the time or date
Enable or disable integrated devices
Correct discrepancies between the installed hardware and configuration settings
Entering the System Setup Program
1. Turn on or restart your system.
2. Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart your system and try again.
NOTE: To ensure an orderly system shutdown, see the documentation that accompanied your operating system.
Responding to Error Messages
You can enter the System Setup program by responding to certain error messages. If an error message appears while the system is booting, make a note of
the message. Before entering the System Setup program, see System Messages for an explanation of the message and suggestions for correcting errors.
NOTE: After installing a memory upgrade, it is normal for your system to send a message the first time you start your system.
Using the System Setup Program
Table 2-1 lists the keys that you use to view or change information on the System Setup program screens and to exit the program.
Table 2-1. System Setup Program Navigation Keys
Keys
Action
Up arrow or <Shift><Tab>
Down arrow or <Tab>
Moves to the previous field.
Moves to the next field.
Spacebar, <+>, <–>, left and right arrows Cycles through the settings in a field. In many fields, you can also type the appropriate value.
<Esc>
<F1>
Exits the System Setup program and restarts the system if any changes were made.
Displays the System Setup program's help file.
NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the system.
System Setup Options
Main Screen
When you enter the System Setup program, the main System Setup program screen appears (see Figure 2-1).
Figure 2-1. Main System Setup Program Screen
Table 2-2 lists the options and descriptions for the information fields that appear on the main System Setup program screen.
NOTE: The options for the System Setup program change based on the system configuration.
NOTE: The System Setup program defaults are listed under their respective options, where applicable.
Table 2-2. System Setup Program Options
Option
Description
System Time
Sets the time on the system's internal clock.
System Date
Memory Information
CPU Information
Boot Sequence
Sets the date on the system's internal calendar.
Displays a screen to view memory information and to configure certain memory features. See Table 2-3.
Determines the order in which the system searches for boot devices during system startup. Available options can include the
diskette drive, CD drive, hard drives, and network. If you have installed a RAC, additional options such as virtual floppy and virtual
CD-ROM may be present.
NOTE: System boot is not supported from an external device attached to a SAS or SCSI adapter. See support.dell.com for the
latest support information about booting from external devices
Hard-Disk Drive
Sequence
Determines the order in which the system searches the hard drives during system startup. The selections depend on the hard
drives installed in your system.
USB Flash Drive
Emulation Type
(Auto default)
Determines the emulation type for a USB flash drive. Hard disk allows the USB flash drive to act as a hard drive. Floppy allows the
USB flash drive to act as a removal diskette drive. Auto automatically chooses an emulation type.
Boot Sequence Retry
(Disabled default)
Enables or disables the Boot Sequence Retry feature. When set to Enabled, the system re-attempts the boot sequence after a 30-
second timeout if the previous boot attempt failed.
Integrated Devices
PCI IRQ Assignment
Displays a screen to configure the system's integrated devices.
Displays a screen to change the IRQ assigned to each of the integrated devices on the PCI bus, and any installed expansion cards
that require an IRQ.
Serial Communication
Displays a screen to configure serial communication, external serial connector, fail-safe baud rate, remote terminal type, and
redirection after boot.
Embedded Server
Management
Displays a screen to configure the front-panel LCD options and to set a user-defined LCD string.
System Security
Displays a screen to configure the system password and setup password features. See Table 2-7. For further information, see
Keyboard NumLock
(On default)
Determines whether your system starts up with the NumLock mode activated on 101- or 102-key keyboards (does not apply to 84-
key keyboards).
Report Keyboard Errors Enables or disables reporting of keyboard errors during the POST. Select Report for host systems that have keyboards attached.
(Report default)
Select Do Not Report to suppress all error messages relating to the keyboard or keyboard controller during POST. This setting does
not affect the operation of the keyboard itself if a keyboard is attached to the system.
Memory Information Screen
Table 2-3 lists the descriptions for the information fields that appear on the Memory Information screen.
Table 2-3. Memory Information Screen
Option
Description
System Memory
Size
Displays the amount of system memory.
System Memory
Type
Displays the type of system memory.
Displays the system memory speed.
System Memory
Speed
Video Memory
Displays the amount of video memory.
System Memory
Testing
Specifies whether system memory tests are run at system boot. Options are Enabled and Disabled.
Redundant Memory Enables or disables the redundant memory feature. When set to Spare Mode, the first rank of memory on each DIMM is reserved for
(Disabled default)
memory sparing. See Memory Sparing Support. Redundant memory feature is disabled if the Node Interleaving field is enabled.
Node Interleaving
If this field is enabled, memory interleaving is supported if a symmetric memory configuration is installed. If this field is set to disabled
(the default), the system can support Non-Uniform Memory architecture (NUMA) (asymmetric) memory configurations.
NOTE: The Node Interleaving field must be set to Disabled when using the redundant memory feature.
Memory Optimizer
Technology
(Enabled default)
Sets the behavior of the two DRAM controllers for memory optimization. When set to Enabled, the two controllers run in parallel 64-bit
mode for improved memory performance (running single-bit ECC).When set to Disabled, the controllers are joined in 128-bit mode
running multi-bit Advanced ECC.
Low Power Mode
(Disabled default)
Enables or disables the low power mode of the memory. When set to Disabled, the memory runs at full speed. When set to Enabled,
the memory runs at a reduced speed to conserve energy.
CPU Information Screen
Table 2-4 lists the options and descriptions for the information fields that appear on the CPU Information screen.
Table 2-4. CPU Information Screen
Option
Description
64-bit
Specifies if the installed processors support 64-bit extensions.
Displays the clock speed of the processors.
Displays the bus speed of the processors.
Core Speed
Bus Speed
Virtualization
Technology
(Enabled default)
NOTE: Disable this feature if your system will not be running virtualization software.
Displays when the processors support Virtualization Technology. Enabled permits virtualization software to use Virtualization
Technology incorporated in the processor design. This feature can only be used by software that supports Virtualization Technology.
Demand-Based
Power Management
(Enabled default)
NOTE: Check your operating system documentation to verify if the operating system supports this feature.
Enables or disables demand-based power management. When enabled, the CPU Performance State tables will be reported to the
operating system; when disabled, the CPU Performance State tables will not be reported to the operating system. If any of the CPUs
do not support demand-based power management, the field will become read-only, and automatically set to Disabled.
Processor X ID
Displays the family, model, and stepping of the specified processor.
Enabling AMD PowerNow!â„¢ Technology
AMD PowerNow! technology controls your system's processor performance automatically, dynamically adjusting the operating frequency and voltage according
to the task at hand. When an application does not require full performance, significant amounts of power can be saved. Performance is designed to still be
responsive, with maximum processor performance being delivered when required, and automatic power savings when possible.
NOTE: AMD PowerNow! support is dependent on the operating system and version used on your system. Disable AMD PowerNow! if your operating
system does not fully support this feature. See your operating system user guide for more information.
To disable the AMD PowerNow! feature, run the System Setup Program and disable the Demand-Based Power Management option on the CPU Information
screen.
®
®
Additionally, for Microsoft Windows operating systems, you will need to install the AMD PowerNow!â„¢ driver to enable this feature. The driver is available on
the Dell OpenManageâ„¢ Service and Diagnostic CD provided with your system, and at support.dell.com.
Integrated Devices Screen
Table 2-5 lists the options and descriptions for the information fields that appear on the Integrated Devices screen.
Table 2-5. Integrated Devices Screen Options
Option
Description
Integrated SAS/RAID
Controller
Enables or disables the integrated SAS controller.
(Enabled default)
Optical Drive
Controller
Enables or disables the integrated optical drive controller.
(On default)
User Accessible USB
Ports
Enables or disables the system's user accessible USB ports. Options are All Ports On, Only Back Ports On, and All Ports Off.
(All Ports On default)
Internal USB Port
(On default)
Enables or disables the system's internal USB port.
Enables or disables the system's internal SD card port.
SD Card Port
Embedded Gb NICx
(NIC1 default:
Enables or disables the system's integrated NIC. Options are Enabled, Enabled with PXE, Enabled with iSCSI Boot, and Disabled.
PXE support allows the system to boot from the network. Changes take effect after the system reboots.
Enabled with PXE;
Other NICs: Enabled)
MAC Address
Displays the MAC address for the integrated 10/100/1000 NIC. This field does not have user-selectable settings.
Displays the NIC features provided by the LOM NIC hardware key installed in the TOE_KEY socket on the system board.
Capability Detected
NOTE: Some LOM features may require the installation of an additional driver.
OS Watchdog Timer
(Disabled default)
NOTE: This feature is usable only with operating systems that support WDAT implementations of the Advanced Configuration and
Power Interface (ACPI) 3.0b specification.
Sets a timer that monitors the operating system for activity and aids in recovery if the system stops responding. When this field is
set to Enabled, the operating system is allowed to initialize the timer. When set to Disabled, the timer is not initialized.
Serial Communication Screen
Table 2-6 lists the options and descriptions for the information fields that appear on the Serial Communication screen.
Table 2-6. Serial Communication Screen Options
Option
Description
Serial Communication
(On without Console
Redirection default)
Options are On without Console Redirection, On with Console Redirection via COM1, On with Console Redirection via
COM2, and Off.
External Serial Connector
(COM1 default)
Specifies whether COM1, COM2, or Remote Access Device has access to the external serial connector for serial
communications.
Failsafe Baud Rate
(115200 default)
Displays the failsafe baud rate used for console redirection when the baud rate cannot be negotiated automatically with
the remote terminal. This rate should not be adjusted.
Remote Terminal Type
Select either VT 100/VT 220 or ANSI.
(VT 100/VT 220 default)
Redirection After Boot
Enables or disables BIOS console redirection after your system boots to the operating system.
(Enabled default)
System Security Screen
Table 2-7 lists the options and descriptions for the information fields that appear on the System Security screen.
Table 2-7. System Security Screen Options
Option
Description
System
Displays the current status of your system's password security feature and allows you to assign and verify a new system password.
Password
NOTE: See Using the System Password for instructions on assigning a system password and using or changing an existing system password.
Setup
Restricts access to the System Setup program in the same way that you restrict access to your system using the system password feature.
Password
NOTE: See Using the Setup Password for instructions on assigning a setup password and using or changing an existing setup password.
Password
Status
Setting the Setup Password option to Enabled prevents the system password from being changed or disabled at system start-up.
To lock the system password, assign a setup password in the Setup Password option and then change the Password Status option to
Locked. In this state, you cannot change the system password using the System Password option and cannot be disabled at system start-
up by pressing <Ctrl><Enter>.
To unlock the system password, enter the setup password in the Setup Password field and then change the Password Status option to
Unlocked. In this state, you can disable the system password at system start-up by pressing <Ctrl><Enter> and then change the password
using the System Password option.
TPM Security
Sets the reporting of the Trusted Platform Module (TPM) in the system.
(Off default)
When set to Off (default), presence of the TPM is not reported to the operating system.
When set to On with Pre-boot Measurements, the system reports the TPM to the operating system and stores the pre-boot measurements
(compliant with Trusted Computing Group standards) to the TPM during POST.
When set to On without Pre-boot Measurements, the system reports the TPM to the operating system and bypasses pre-boot
measurements.
TPM
Changes the operational state of the TPM.
Activation
When set to Activate, the TPM is enabled and activated at default settings.
When set to Deactivate, the TPM is disabled and deactivated.
The No Change state initiates no action. The operational state of the TPM remains unchanged (all user settings for the TPM are preserved).
NOTE: This field is read-only when TPM Security is set to Off.
TPM Clear
(No default)
NOTICE: Clearing the TPM will cause loss of all encryption keys in the TPM. This option will prevent booting to the operating system and will
result in loss of data if the encryption keys cannot be restored. Be sure to back up the TPM keys prior to enabling this option.
When set to Yes, all the contents of the TPM are cleared.
NOTE: This field is read-only when TPM Security is set to Off.
Power Button Turns system's power off and on. On an ACPI-compliant operating system, the system performs an orderly shutdown before power is turned
(Enabled
off.
default)
The button is enabled in the System Setup program. When disabled, the button can only turn on system power.
NOTE: You can still turn on the system by using the power button, even if the Power Button option is set to Disabled.
NMI Button
(Disabled
default)
NOTICE: Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing
this button halts the operating system and displays a diagnostic screen.
Sets the NMI feature On or Off.
AC Power
Recovery
Determines how the system reacts when power is restored to the system. If system is set to Last, the system returns to the last power
state. On turns on the system after power is restored. When set to Off, the system remains off after power is restored.
(Last default)
Exit Screen
After you press <Esc> to exit the System Setup program, the Exit screen displays the following options:
l
l
l
Save Changes and Exit
Discard Changes and Exit
Return to Setup
System and Setup Password Features
NOTICE: The password features provide a basic level of security for the data on your system. If your data requires more security, use additional forms
of protection, such as data encryption programs.
NOTICE: Anyone can access the data stored on your system if you leave the system running and unattended without having a system password
assigned or if you leave your system unlocked so that someone can disable the password by changing a jumper setting.
Your system is shipped to you without the system password feature enabled. If system security is a concern, operate your system only with system password
protection.
To change or delete an existing password, you must know the password (see Deleting or Changing an Existing System Password). If you forget your
password, you cannot operate your system or change settings in the System Setup program until a trained service technician changes the password jumper
setting to disable the passwords, and erases the existing passwords. This procedure is described in Disabling a Forgotten Password.
Using the System Password
After a system password is assigned, only those who know the password have full use of the system. When the System Password option is set to Enabled,
the system prompts you for the system password after the system starts.
Assigning a System Password
Before you assign a system password, enter the System Setup program and check the System Password option.
When a system password is assigned, the setting shown for the System Password option is Enabled. If the setting shown for the Password Status is
Unlocked, you can change the system password. If the Password Status option is Locked, you cannot change the system password. When the system
password feature is disabled by a jumper setting, the system password is Disabled, and you cannot change or enter a new system password.
When a system password is not assigned and the password jumper on the system board is in the enabled (default) position, the setting shown for the
System Password option is Not Enabled and the Password Status field is Unlocked. To assign a system password:
1. Verify that the Password Status option is set to Unlocked.
2. Highlight the System Password option and press <Enter>.
3. Type your new system password.
You can use up to 32 characters in your password.
As you press each character key (or the spacebar for a blank space), a placeholder appears in the field.
The password assignment is not case-sensitive. However, certain key combinations are not valid. If you enter one of these combinations, the system
beeps. To erase a character when entering your password, press <Backspace> or the left-arrow key.
NOTE: To escape from the field without assigning a system password, press <Enter> to move to another field, or press <Esc> at any time prior to
completing step 5.
4. Press <Enter>.
5. To confirm your password, type it a second time and press <Enter>.
The setting shown for the System Password changes to Enabled. Exit the System Setup program and begin using your system.
6. Either reboot your system now for your password protection to take effect or continue working.
NOTE: Password protection does not take effect until you reboot the system.
Using Your System Password to Secure Your System
NOTE: If you have assigned a setup password (see Using the Setup Password), the system accepts your setup password as an alternate system
password.
When the Password Status option is set to Unlocked, you have the option to leave the password security enabled or to disable the password security.
To leave the password security enabled:
1. Turn on or reboot your system by pressing <Ctrl><Alt><Del>.
2. Type your password and press <Enter>.
To disable the password security:
1. Turn on or reboot your system by pressing <Ctrl><Alt><Del>.
2. Type your password and press <Ctrl><Enter>.
When the Password Status option is set to Locked whenever you turn on your system or reboot your system by pressing <Ctrl><Alt><Del>, type your
password and press <Enter> at the prompt.
After you type the correct system password and press <Enter>, your system operates as usual.
If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the
correct password. After the third unsuccessful attempt, the system displays an error message showing the number of unsuccessful attempts and that the
system has halted and will shut down. This message can alert you to an unauthorized person attempting to use your system.
Even after you shut down and restart the system, the error message continues to be displayed until the correct password is entered.
NOTE: You can use the Password Status option in conjunction with the System Password and Setup Password options to further protect your system
from unauthorized changes.
Deleting or Changing an Existing System Password
1. When prompted, press <Ctrl><Enter> to disable the existing system password.
If you are asked to enter your setup password, contact your network administrator.
2. Enter the System Setup program by pressing <F2> during POST.
3. Select the System Security screen field to verify that the Password Status option is set to Unlocked.
4. When prompted, type the system password.
5. Confirm that Not Enabled is displayed for the System Password option.
If Not Enabled is displayed for the System Password option, the system password has been deleted. If Enabled is displayed for the System Password
option, press the <Alt><b> key combination to restart the system, and then repeat steps 2 through 5.
Using the Setup Password
Assigning a Setup Password
You can assign (or change) a setup password only when the Setup Password option is set to Not Enabled. To assign a setup password, highlight the Setup
Password option and press the <+> or <–> key. The system prompts you to enter and verify the password. If a character is illegal for password use, the
system beeps.
NOTE: The setup password can be the same as the system password. If the two passwords are different, the setup password can be used as an
alternate system password. However, the system password cannot be used in place of the setup password.
You can use up to 32 characters in your password.
As you press each character key (or the spacebar for a blank space), a placeholder appears in the field.
The password assignment is not case-sensitive. However, certain key combinations are not valid. If you enter one of these combinations, the system beeps.
To erase a character when entering your password, press <Backspace> or the left-arrow key.
After you verify the password, the Setup Password setting changes to Enabled. The next time you enter the System Setup program, the system prompts you
for the setup password.
A change to the Setup Password option becomes effective immediately (restarting the system is not required).
Operating With a Setup Password Enabled
If Setup Password is set to Enabled, you must enter the correct setup password before you can modify most of the System Setup options. When you start
the System Setup program, the program prompts you to enter a password.
If you do not enter the correct password in three attempts, the system lets you view, but not modify, the System Setup screens—with the following exception:
If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password (however, you cannot
disable or change an existing system password).
NOTE: You can use the Password Status option in conjunction with the Setup Password option to protect the system password from unauthorized
changes.
Deleting or Changing an Existing Setup Password
1. Enter the System Setup program and select the System Security option.
2. Highlight the Setup Password option, press <Enter> to access the setup password window, and press <Enter> twice to clear the existing setup
password.
The setting changes to Not Enabled.
Disabling a Forgotten Password
Baseboard Management Controller Configuration
The Baseboard Management Controller (BMC) enables configuring, monitoring, and recovery of systems remotely. BMC provides the following features:
l
l
l
l
l
l
Uses the system's integrated NIC
Enables fault logging and SNMP alerting
Provides access to system event log and sensor status
Allows control of system functions including power on and off
Functions independently of the system's power state or the system's operating system
Provides text console redirection for system setup, text-based utilities, and operating system consoles
NOTE: To remotely access the BMC through the integrated NIC, you must connect the network connection to integrated NIC1.
For additional information on using BMC, see the documentation for the BMC and systems management applications.
Entering the BMC Setup Module
1. Turn on or restart your system.
2. Press <Ctrl-E> when prompted after POST.
If your operating system begins to load before you press <Crtl-E>, allow the system to finish booting, and then restart your system and try again.
BMC Setup Module Options
For information about the BMC Setup Module options and how to configure the emergency management port (EMP), see the BMC User's Guide.
Troubleshooting Your System
Dellâ„¢ PowerEdgeâ„¢ R805 Systems Hardware Owner's Manual
Safety First—For You and Your System
To perform certain procedures in this document, you must remove the system cover and work inside the system. While working inside the system, do not
attempt to service the system except as explained in this guide and elsewhere in your system documentation.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Start-Up Routine
Table 4-1. Start-Up Routine Indications
Look/listen for:
Action
A status or error message displayed on the front-panel LCD.
An error message displayed on the monitor.
Alert messages from the systems management software.
The monitor's power indicator.
See the systems management software documentation.
The keyboard indicators.
The USB diskette drive activity indicator.
The USB CD drive activity indicator.
The CD drive activity indicator.
The hard-drive activity indicator.
Checking the Equipment
This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perform
Troubleshooting IRQ Assignment Conflicts
Most PCI devices can share an IRQ with another device, but they cannot use an IRQ simultaneously. To avoid this type of conflict, see the documentation for
Table 4-2. IRQ Assignment Defaults
IRQ Line Assignment
IRQ0
IRQ1
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
IRQ8
IRQ9
IRQ10
IRQ11
IRQ12
IRQ13
IRQ14
IRQ15
System timer
Keyboard controller
Interrupt controller 1 to enable IRQ8 through IRQ15
Serial port 2 (COM2 and COM4)
Serial port 1 (COM1 and COM3)
Remote access controller
Reserved
Reserved
Real-time clock
ACPI functions (used for power management)
Available
Available
Reserved
Math coprocessor
IDE CD drive controller
Available
Troubleshooting External Connections
Loose or improperly connected cables are the most likely source of problems for the system, monitor, and other peripherals (such as a printer, keyboard,
mouse, or other external device). Ensure that all external cables are securely attached to the external connectors on your system. See Front-Panel Features
and Indicators and Back-Panel Features and Indicators for the front- and back-panel connectors on your system.
Troubleshooting the Video Subsystem
Problem
l
l
Monitor is not working properly.
Video memory is faulty.
Action
1. Check the system and power connections to the monitor.
2. Swap the monitor with another working monitor to see if this resolves the problem.
3. Determine whether the system has an expansion card with a video output connector.
In this system configuration, the monitor cable should normally be connected to the connector on the expansion card, not to the system's integrated
video connector.
To verify that the monitor is connected to the correct video connector, turn off the system and wait for 1 minute, then connect the monitor to the other
video connector and turn the system on again.
4. Determine whether the system has monitors attached to both the front and rear video connectors.
The system supports only one monitor attached to either the front or rear video connector. When a monitor is connected to the front panel, the back-
panel video, keyboard, and mouse connectors are disabled.
If two monitors are attached to the system, disconnect one monitor. If the problem is not resolved, continue to the next step.
5. If possible, run the appropriate online diagnostic test. See Using Server Administrator Diagnostics.
If the tests run successfully, the problem is not related to video hardware.
Troubleshooting the Keyboard
Problem
l
l
System message indicates a problem with the keyboard
Keyboard is not functioning properly
Action
1. Enter the System Setup program and ensure that the USB ports are enabled. See Using the System Setup Program.
2. Examine the keyboard and its cable for signs of damage.
3. Swap the faulty keyboard with a working keyboard.
If the problem is resolved, replace the faulty keyboard.
Troubleshooting the Mouse
Problem
l
l
System message indicates a problem with the mouse.
Mouse is not functioning properly.
Action
If the test fails, continue to the next step.
2. Examine the mouse and its cable for signs of damage.
If the mouse is damaged, continue to the next step.
3. Swap the faulty mouse with a working mouse.
If the problem is resolved, replace the faulty mouse.
4. Enter the System Setup program and ensure that the USB port is enabled. See Using the System Setup Program.
Troubleshooting Basic I/O Functions
Problem
l
l
Error message indicates a problem with a serial port.
Device connected to a serial port is not operating properly.
Action
1. Enter the System Setup program and ensure that the serial port is enabled, and the serial port/COM ports are configured appropriately for any
2. If the problem is confined to a particular application, see the application documentation for specific port configuration requirements that the program
may require.
Troubleshooting a Serial I/O Device
Problem
l
Device connected to the serial port is not operating properly.
Action
1. Turn off the system and any peripheral devices connected to the serial port.
2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.
If the problem is resolved, replace the interface cable.
3. Turn off the system and the serial device, and swap the device with a comparable device.
4. Turn on the system and the serial device.
If the problem is resolved, replace the serial device.
Troubleshooting a USB Device
Problem
l
l
System message indicates a problem with a USB device.
Device connected to a USB port is not operating properly.
Action
1. Enter the System Setup program, and ensure that the USB ports are enabled. See Using the System Setup Program.
2. Turn off the system and any USB devices.
3. Disconnect the USB devices, and connect the malfunctioning device to the other USB connector.
4. Turn on the system and the reconnected device.
5. If possible, swap the interface cable with a working cable.
If the problem is resolved, replace the interface cable.
6. Turn off the system and the USB device, and swap the device with a comparable device.
7. Turn on the system and the USB device.
If the problem is resolved, replace the USB device.
Troubleshooting a NIC
Problem
l
NIC cannot communicate with network.
Action
l
l
If the link indicator does not light, check all cable connections.
If the activity indicator does not light, the network driver files might be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC's documentation.
l
l
Change the autonegotiation setting, if possible.
Use another connector on the switch or hub.
If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.
3. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.
4. Enter the System Setup program and confirm that the NICs are enabled. See Using the System Setup Program.
5. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed. See the network equipment documentation.
6. Ensure that all network cables are of the proper type and do not exceed the maximum length. See Network Cable Requirements in your Getting Started
Guide.
Troubleshooting a Wet System
Problem
l
l
Liquid spilled on the system.
Excessive humidity.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
4. Let the system dry thoroughly for at least 24 hours.
6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
7. If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed. See Installing an Expansion Card.
Troubleshooting a Damaged System
Problem
l
System was dropped or damaged.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
2. Ensure that the following components are properly installed:
l
l
l
l
l
l
Expansion cards and risers
Power supplies
Fans
Processors and heat sinks
Memory modules
Drive-carrier connections to the SAS/SATA backplane board, if applicable
3. Ensure that all cables are properly connected.
Troubleshooting the System Battery
Problem
l
l
l
System message indicates a problem with the battery.
System Setup program loses system configuration information.
System date and time do not remain current.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation
is caused by a defective battery.
Action
2. Turn off the system and disconnect it from the electrical outlet for at least one hour.
3. Reconnect the system to the electrical outlet and turn on the system.
4. Enter the System Setup program.
If the date and time are not correct in the System Setup program, replace the battery. See System Battery.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the
System Setup program, the problem may be caused by software rather than by a defective battery.
Troubleshooting Power Supplies
Problem
l
l
l
System-status indicators are amber.
Power-supply fault indicators are amber.
Front-panel status LCD indicates a problem with the power supplies.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
2. Locate the faulty power supply.
NOTICE: You can hot-plug the power supplies. One power supply must be installed for the system to operate. The system is in the redundant mode
when two power supplies are installed. Remove and install only one power supply at a time in a system that is powered on. Operating the system for
extended periods of time with only one power supply installed, without a power supply blank installed, can cause the system to overheat.
3. Ensure that the power supply is properly installed by removing and reinstalling it. See Replacing a Power Supply.
NOTE: After installing a power supply, allow several seconds for the system to recognize the power supply and to determine if it is working
properly. The power indicator turns green to signify that the power supply is functioning properly. See Power Indicator Codes.
4. Check the indicators to see if the problem is resolved. If not, remove the faulty power supply. See Removing a Power Supply.
Troubleshooting System Cooling Problems
Problem
l
Systems management software issues a fan-related error message.
Action
Ensure that none of the following conditions exist:
l
l
l
l
Ambient temperature is too high.
External airflow is obstructed.
Cables inside the system obstruct airflow.
Troubleshooting a Fan
Problem
l
l
l
System-status indicator is amber.
Systems management software issues a fan-related error message.
Front panel LCD indicates a problem with the fan.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: The cooling fans are hot-pluggable. To maintain proper cooling while the system is on, only replace one fan at a time.
3. Locate the faulty fan indicated by the LCD display or diagnostic software. For the identification number of each fan, see Figure 3-9.
4. Ensure that the faulty fan is fully seated in the fan bracket and attached to the power connector. See System Fans.
NOTE: Wait 30 seconds for the system to recognize the fan and determine whether it is working properly.
Troubleshooting System Memory
Problem
l
l
l
Faulty memory module.
Faulty system board.
Front-panel status LCD indicates a problem with system memory.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. If the system is operational, run the appropriate online diagnostic test. See Using Server Administrator Diagnostics.
If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program. If the problem is not resolved or if the system is not
operational, continue to the next step.
2. Turn off the system and attached peripherals, unplug the system from the power source and press the power button, and then reconnect the system to
power.
3. Turn on the system and attached peripherals and, as the system boots, note the messages on the screen.
If you receive any other system message that indicates a nonspecific memory problem, continue to the next step.
4. Enter the System Setup program and check the system memory setting. See Using the System Setup Program. Make any changes to the memory
settings, if needed.
If the installed memory does not match the amount of memory shown in the System Setup program, proceed to the next step.
5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
7. Check the memory banks and ensure that they are populated correctly. See General Memory Module Installation Guidelines. Make any necessary
changes.
If the memory modules are populated correctly, continue to the next step.
10. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
11. Enter the System Setup program and check the system memory setting. See Using the System Setup Program.
If the amount of memory installed still does not match the system memory setting, then proceed to the next step.
12. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
14. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module. Otherwise, swap the memory module in
the first DIMM socket with a module of the same type and capacity that is known to be good. See Installing Memory Modules.
16. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
17. As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system.
18. If the memory problem is still indicated, repeat step 12 through step 17 for each memory module installed.
Troubleshooting an SD Card or Internal USB Key
Problem
l
System cannot read data from an SD card or USB key.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Enter the System Setup program and ensure that the SD card or USB key port is enabled. See Using the System Setup Program.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
4. Reseat the SD card or USB key.
6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, proceed to the next step.
8. Insert a different SD card or USB key that you know works properly.
10. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Troubleshooting an Optical Drive
Problem
l
l
System cannot read data from a CD or DVD in an optical drive.
Optical drive indicator does not blink during boot.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
1. Try using a different CD or DVD that you know works properly.
2. Enter the System Setup program and ensure that the optical drive controller is enabled. See Using the System Setup Program.
4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6. Ensure that the interface cable is securely connected to the optical drive and to the system board.
7. Ensure that a power cable is properly connected to the drive.
9. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Troubleshooting an External Tape Drive
Problem
l
l
l
l
Defective tape drive
Defective tape cartridge
Missing or corrupted tape-backup software or tape drive device driver
Defective tape drive controller
Action
1. Remove the tape cartridge you were using when the problem occurred, and replace it with a tape cartridge that you know works.
2. Ensure that the SCSI or SAS device drivers for the tape drive are installed and are configured correctly. See your tape drive documentation for more
information about device drivers.
3. Reinstall the tape-backup software as instructed in the tape-backup software documentation.
4. Ensure that the tape drive's interface cable is fully connected to the tape drive and the external port on the SCSI or SAS controller card.
5. For SCSI tape drives, verify that the tape drive is configured for a unique SCSI ID number and that the tape drive is terminated or not terminated, based
on the interface cable used to connect the drive.
See the documentation for the tape drive for instructions on selecting the SCSI ID number and enabling or disabling termination.
8. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
10. Reseat the SAS or SCSI controller card in the expansion card slot.
12. Reconnect the system to the electrical outlet, and turn on the system, including attached peripherals.
13. If the problem is not resolved, see the documentation for the tape drive for additional troubleshooting instructions.
14. If you cannot resolve the problem, see Getting Help for information on obtaining technical assistance.
Troubleshooting a Hard Drive
Problem
l
l
Device driver error.
One or more hard drives not recognized by the system.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
3. If you are experiencing problems with multiple hard drives, skip to step 8. For a problem with a single hard drive, continue to the next step.
4. Turn off your system, reseat the hard drive, and restart the system.
5. If your system has the optional battery-cached SAS RAID controller daughter card, perform the following steps.
a. Restart the system and press <Ctrl><R> to enter the host adapter configuration utility program.
See the documentation supplied with the host adapter for information about the configuration utility.
b. Ensure that the hard drive has been configured correctly for the RAID.
c. Exit the configuration utility and allow the system to boot to the operating system.
6. Ensure that the required device drivers for your controller daughter card are installed and are configured correctly. See the operating system
documentation for more information.
NOTICE: Skip the following step if your hard drives are in a RAID configuration.
7. For non-RAID configurations only, remove the hard drive and swap its drive bay location with another hard drive that is functioning properly.
If the problem is resolved, reinstall the hard drive in the original bay. See Installing a Hot-Plug Hard Drive.
If the hard drive functions properly in the original bay, the drive carrier could have intermittent problems. Replace the hard-drive carrier. See Getting
If the hard drive functioned properly in another bay but does not function in the original bay, the SAS/SATA backplane has a defective connector. See
8. Check the cable connections inside the system:
a. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
c. Verify that the cable connections between SAS/SATA backplane(s) and the SAS daughter card are correct. See Installing a SAS Controller
d. Verify that the SAS cables are securely seated in their connectors.
e. Verify that the power connectors on the SAS/SATA backplane(s) are securely seated in their connectors.
g. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
Troubleshooting a SAS Controller Daughter Card
NOTE: When troubleshooting a SAS controller daughter card, also see the documentation for your operating system and the controller daughter card.
Problem
l
l
Error message indicates a problem with the SAS controller daughter card.
SAS controller daughter card performs incorrectly or not at all.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
2. Enter the System Setup program and ensure that the SAS controller daughter card is enabled. See Using the System Setup Program.
3. Restart the system and press one of the following applicable key sequences to enter the configuration utility program:
l
l
<Ctrl><C> for a SAS controller
<Ctrl><R> for the optional battery-cached SAS RAID controller
See the controller's documentation for information about configuration settings.
4. Check the configuration settings, make any necessary corrections, and restart the system.
If the problem is not resolved, continue to the next step.
6. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
8. Ensure that the controller card is firmly seated in its connector. See SAS Controller Daughter Card.
9. If present, ensure that the RAID battery is properly installed and connected.
10. Verify that the cable connections between the SAS/SATA backplane(s) and the SAS controller daughter card are correct. See Installing a SAS Controller
11. Ensure that the cables are firmly connected to the SAS controller daughter card and the SAS/SATA backplane board.
13. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. If the problem persists, see Getting Help.
Troubleshooting Expansion Cards
NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.
Problem
l
l
Error message indicates a problem with an expansion card.
Expansion card performs incorrectly or not at all.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
5. Ensure that each expansion card is firmly seated in its connector. See Installing an Expansion Card.
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem persists, go to the next step.
8. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13. Run the appropriate online diagnostic test.
a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
c. Reinstall one of the expansion cards.
e. Run the appropriate diagnostic test.
Troubleshooting the Microprocessors
Problem
l
l
l
Error message indicates a processor problem.
Front-panel status LCD indicates a problem with the processors or system board.
A heat sink is not installed for each processor.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as
authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
4. Inspect each processor and heat sink and ensure that they are properly installed.
6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
7. Run the appropriate online diagnostic test.
|
HP Hewlett Packard Hewlett Packard Computer Monitor 2209T User Manual
Hanns G HW192 User Manual
Garland SUME 100D1 User Manual
Eizo EIZO FlexScan S1501 User Manual
Dialogic Brooktrout 931 107 05 User Manual
Daewoo DP SP22 User Manual
Black Decker CTO800 User Manual
Avaya 38DHB0002UKFD User Manual
American Dynamics Tyco AD9410 User Manual
ADC MLN7400 User Manual