6. Replace the cover.
System Requirements
This board must be installed in an enclosure that
meets the following specifications:
Setting Termination Jumpers
Before installing your board, set termination for the
BRI line if necessary. See Figure 5 for the location of
the termination switches.
7. Turn on your computer.
Note: Dialogic® Brooktrout® boards should not be present in the
computer during the installation of any operating system.
The operating system might misinterpret the board as being
some other device, with unpredictable consequences.
A Pentium or later host processor
A PCI bus slot that runs at least 33 MHz and is
32 or 64 bits wide. See Recognizing PCI Slots for
more information.
Recognizing PCI Slots
The PCI connectors in the computer chassis usually
appear as white slots. The TruFax® BRI board has a
PCI board edge connector. It can be inserted into any
of the PCI slots shown in Figure 3.
Set jumpers as follows (See Figure 2 for details):
Temperature: 0 C - 50 C
Humidity: 10% - 95% (non-condensing)
Power Requirements:
Installing the Dialogic®
Brooktrout® TruFax® BRI
PCI Board
Board
+5 V +3.3 V +12 V -12 V Total Power
0.8A 0A 0A 0A 4.0 W
0.9A 0A 0A 0A 4.5 W
Single channel
Dual channel
Jumper is removed
Jumper is in place
Universal PCI Board Edge Connector
Part Number: 931-107-05
(ISDN BRI line is not terminated)
(ISDN BRI line is terminated)
The Dialogic® Brooktrout® TruFax® BRI
(Basic Rate Interface ISDN) PCI boards are half-
sized, single-slot PCI-bus compatible fax processing
boards. They provide the following:
3.3V 32-Bit Connector
Figure 2. Termination Jumpers
The following is also required:
Telephone service: BRI interface
5V 32-Bit Connector
3.3V 64-Bit Connector
When the jumpers are removed from both
switches for the appropriate port, there is no
termination.
When jumpers are present, the lines are
terminated with 100 ohms (this is how the boards
are shipped).
On-board BRI connections
Up to four V.17 fax channels per board
5V 64-Bit Connector
Setting the Module Number
Set each board to a unique module number to easily
identify the resources associated with a specific board
in a multi-board system.
Insert the connector into any of these slots.
The TruFax® BRI PCI Series boards can be used in
either 3.3V or 5V bus (signaling) slots.
Figure 3. PCI Slots
You need a fax application to use a TruFax® BRI
board. Dialogic does not provide the application or a
driver for this board. A driver comes with the
application that you purchase.
Use the SW-1 rotary switch (Figure 1) to set a unique
module number for each Dialogic® Brooktrout®
board. See Figure 5 for the switch location. Select a
number from 2 - F on the rotary switch. Settings 0 and
1 are reserved and cannot be used.
Connecting the Phone Service
Brooktrout® Board
The appropriate telephone service and hookups must
be installed at your site in order to connect to
telephone service. The following table shows the
channel/port relationship:
This installation guide provides information about:
System Requirements (including telephone
service)
To install your board:
1. Turn off your PC and remove the cover.
Setting the Module Number
Channel Number RJ-45 Port
Type of Service
Caution: A small amount of static electricity can destroy
the sensitive components on your board. To prevent
static damage, always connect yourself to ground using
a ground strap before touching a circuit board. Handle
boards only by the edges or metal mounting brackets
and transport boards in an anti-static bag.
Setting Termination Jumpers for the BRI Line
Installing the Dialogic® Brooktrout® Board
Recognizing PCI Slots
Connecting the Phone Service
Understanding LED Signals
0
1
2
3
A
A
B
B
BRI S/T
BRI S/T
BRI S/T
BRI S/T
Figure 1. Rotary Switch (SW-1)
2. If the system has a PCI expansion hold-down bar,
remove it.
Use the cable supplied with the board. Use these
instructions to connect your board to BRI service:
1. Plug one end of the cable into the telephone
connector on the board.
Using the Dialogic® Brooktrout® TruFax® BRI
Board
3. Locate a free PCI bus slot and remove the slot
cover.
Getting Help
4. Carefully align the board with the slot and firmly
seat the board into the slot.
Connect to Port A for channels 0 and 1 or to
Port B for channels 2 and 3 (see Figure 5 to
locate ports).
5. Tighten the mounting bracket screw to secure the
board to the chassis.
2. Plug the other end into the wall connector for
your BRI service.
Warning: When installing the board, be sure that the
mounting bracket is securely fastened to the chassis and
the chassis is plugged into a grounded three prong plug.
Improper chassis or bracket grounding can result in
harmful or fatal electrical shock as well as component
damage.
Note: Port B is not present on the TruFax® BRI single port
version.
|