		 BenQ RS232 Code   
					Model: SP920   
					1. Connection :   
					The below shows the illustration of connection between control terminal and Projector.   
					<Pin assignment >   
					Pin   
					1 
					Description   
					RX   
					Pin   
					2 
					Description   
					CTS   
					8 
					7 
					4 
					6 
					5 
					3 
					2 
					1 
					3 
					NC   
					4 
					GND   
					5 
					RTS   
					6 
					NC   
					7 
					TX   
					8 
					GND   
					 
					 
					Make sure that your computer and projector are turned off before connection.   
					Power on the computer first, and then plug the power cord of the projector.   
					(It may cause Com port incorrect function, if you do not follow this instruction)   
					Adapters may be necessary depending on the PC connected to this projector. Please contact with   
					your dealer for further details.   
					 
					2. Interface Setting :   
					Baud Rate   
					115200 bps (default)   
					Changeable(2400/4800/9600/14400/19200/38400/57600/115200)   
					Setting in OSD menu   
					Data Length   
					Parity Check   
					Stop Bit   
					8 bit   
					None   
					1 bit   
					None   
					Flow Control   
				Function   
					Type   
					Operation   
					ASCII   
					Write   
					Write   
					Read   
					Zoom out   
					<CR>*zoomO#<CR>   
					<CR>*auto#<CR>   
					Picture Setting   
					Auto   
					Lamp Hour   
					Lamp-2 Hour   
					Dual Brightest   
					Dual Reliable   
					Single Alternative   
					<CR>*ltim=?#<CR>   
					<CR>*ltim2=?#<CR>   
					<CR>*lampm=dualbr#<CR>   
					<CR>*lampm=dualre#<CR>   
					<CR>*lampm=single#<CR>   
					Read   
					Write   
					Write   
					Write   
					Read   
					Lamp Control   
					Lamp Mode Status <CR>*lampm=?#<CR>   
					Write   
					Write   
					Write   
					Write   
					Write   
					Write   
					Write   
					Menu On   
					Menu Off   
					Up   
					<CR>*menu=on#<CR>   
					<CR>*menu=off#<CR>   
					<CR>*up#<CR>   
					Menu Control   
					Down   
					Right   
					<CR>*down#<CR>   
					<CR>*right#<CR>   
					<CR>*left#<CR>   
					Left   
					Enter   
					<CR>*enter#<CR>   
					NOTE :   
					Note1: If the command format is illegal, it will echo “Illegal format”.   
					Note2: If the command is not supported, it will echo “Unsupported item”.   
					Note3: If the command is disabled, it will echo “Block item”.   
					Note4: All the echo text will be same with the command you execute except query command   
				 |