Installation and Operation Manual
Celerity FC host adapters
Celerity FC-41EN
4-Gb FC single channel host adapter
Celerity FC-42EN
4-Gb FC dual channel host adapter
Celerity FC-44ES
4-Gb FC quad channel host adapter
Celerity FC-42ES
4-Gb FC dual channel host adapter
Celerity FC-41ES
4-Gb FC single channel host adapter
Celerity FC-42XS
4-Gb FC dual channel host adapter
Celerity FC-41XS
4-Gb FC single channel host adapter
Celerity FC-21PS
2-Gb FC single channel host adapter
© 2007 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective
holders. No part of this manual may be reproduced in any form or by any means without the express written
permission of ATTO Technology, Inc.
3/2007
Document Control Number: PRMA-0344-000
Contents
3 Installing and updating drivers .........................................................13
4 Hardware installation ..........................................................................17
ATTO Technology Inc.Celerity FC Storage Adapters Installation and Operation Manual
1 ATTO provides Fibre Channel solutions
The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and
scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching,
backup and data management. Specifically designed to enhance the functionality of third party fabric
hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.
Celerity FC-41EN Adapter
The Celerity FC-41EN is a single-channel host
adapter. With 4-Gb FC speeds of up to 800 MB/sec.,
the FC-41EN supports the most demanding
application requirements.
Environmental & physical specifications
•
Conforms to PCIe low profile form factor
specifications
•
•
•
•
•
Operating temperature: 0 to 45º C (32-113º F)
Storage temperature: -40 to 70ºC (-40 to 158º F)
Relative humidity: 10 to 90% non-condensing
100 lf/m (minimum) airflow recommended
Conforms to PCI Express low-profile form-factor
specification
The FC-41EN takes advantage of the latest in host
interconnect technology, PCI Express, a serial, high-
speed connection that supports aggregate throughout
up to 2 GB/sec.full-duplex. The FC-41EN is software
compatible with existing PCI and PCI-X products
using the same device drivers as other Celerity FC
family products, simplifying user installation and
support. It is backward compatible with existing 2-Gb
and 1-Gb FC infrastructures, protecting existing
technology investments.
•
•
•
•
12V @ 0.5A (max)
Length: 5.600 inches
Height: 2.712 inches
RoHS compliant
External connectivity
•
Easy-to-install full and low-profile connection
plates
Hardware specifications
•
•
External LEDs for on-line and speed status
A pluggable optical LC SFP transceiver included
•
•
•
•
1 Fibre Channel port
4-Gigabit data transfer rate
800 MB/sec. maximum full-duplex throughput
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,
FC-AL2, FC-PLDA, FC-FLA
Software specifications
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Mac® OS X (10.4.x or later)
Red Hat Linux (2.4 and 2.6 kernels)
SUSE Linux (2.6 kernel)
•
•
•
•
•
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 4
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand automatic negotiation between 4-
Gb, 2-Gb and 1-Gb Fibre Channel
Supports initiator and target modes
Supports Windows® FDMI and WMI
Supports exclusive ATTO Advanced Data
Streaming (ADS™) technology
•
•
•
Host bus specifications
•
x4 mechanical and x4 electrical PCI Express
interconnect
•
•
Conforms to PCI Express Base Spec 1.0a
Conforms to PCI Express CEM Spec 1.0a
1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-42EN Adapter
•
•
•
Supports initiator and target modes
Supports Windows FDMI and WMI
Supports exclusive ATTO Advanced Data
Streaming (ADS) technology
The Celerity FC-42EN is a dual-channel host adapter,
providing port density for Enterprise server and
workstation applications. With 4-Gb FC speeds of up
to 800 MB/sec.full-duplex per channel, the FC-42EN
supports the most demanding application
requirements.
Host bus specifications
•
x4 mechanical and x4 electrical PCI Express
interconnect
Conforms to PCI Express Base Spec 1.0a
Conforms to PCI Express CEM Spec 1.0a
The FC-42EN takes advantage of the latest in host
interconnect technology, PCI Express, a serial, high-
speed connection that supports aggregate throughout
up to 2 GB/sec. The FC-42EN is software compatible
with existing PCI and PCI-X products using the same
device drivers as other Celerity FC family products,
simplifying user installation and support. It is
backward compatible with existing 2-Gb and 1-Gb FC
infrastructures, protecting existing technology
investments.
•
•
Environmental & physical specifications
•
•
•
•
•
Operating temperature: 0-45º C (32º to 113º F)
Storage temperature:-40 to 70ºC (-40º to 158º F)
Relative humidity: 10 to 90% non-condensing
100 lf/m (minimum) airflow recommended
Conforms to PCI Express low-profile form-factor
specification
12V @ 0.5A (max)
Length: 5.600 inches
Height: 2.712 inches
RoHS compliant
•
•
•
•
Hardware specifications
•
•
•
2 independent Fibre Channel ports
4-Gigabit data transfer rates per channel
800 MB/sec. maximum full-duplex throughput
per channel
External connectivity
•
•
•
Easy-to-install full and low-profile connection
plates
External LEDs for on-line and speed status for
each channel
2 pluggable optical LC SFP transceivers
included
•
•
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,
FC-AL2, FC-PLDA, FC-FLA
•
•
•
•
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 4
Software specifications
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Mac OS X (10.4.x or later)
Red Hat Linux (2.4 and 2.6 kernels)
SUSE Linux (2.6 kernel)
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand automatic negotiation between 4-
Gb, 2-Gb and 1-Gb Fibre Channel
2
Celerity FC-44ES Adapter
•
•
Conforms to PCI Express CEM Spec 1.0a
PCI Express to PCI/PCI-X Bridge spec 1.0
The Celerity FC-44ES uses PCI Express Interconnect
and 4-Gigabit Fibre Channel to provide 4-Gb FC
speeds of up to 800 MB/sec. per channel. The FC-
44ES supports high-definition video, rich content
databases and other high bandwidth environments.
Environmental & physical specifications
•
Conforms to PCI standard height, half length
form-factor specifications
•
•
•
•
•
•
•
•
•
Length: 6.525 inches
Height: 3.81 inches
Operating temperature: 0-45ºC (32-113ºF)
Storage temperature: -40 to 70ºC (-40 to 158ºF)
Relative humidity: 5 to 95% non-condensing
12V@ 2.1A (max.)
3.3V @ 3.0A (max.)
100 lf/m (minimum) airflow recommended
RoHS compliant
The FC-44ES uses PCI Express, a serial, high-speed
connection that supports aggregate throughput up to 4
GB/sec. (x8 PCIe) full-duplex. With software
compatible with existing PCI and PCI-X products, the
FC-44ES uses the same device drivers as other
Celerity FC family products, simplifying installation
and support.
Hardware specifications
•
•
•
4 independent Fibre Channel ports
4-Gigabit data transfer rates per channel
800 MB/sec. maximum full-duplex throughput
per channel
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP,
FC-AL2, FC-PLDA, FC-FLA
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
External connectivity
•
•
Easy-to-install full height connection plate
External LEDs for on-line and speed status for
each channel
•
•
•
4 pluggable optical LC SFP transceivers
included
Software specifications
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Mac OS X (10.4.x or later)
Red Hat Linux (2.4 and 2.6 kernel)
SUSE Linux (2.6 kernel)
•
•
•
•
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
•
•
•
Supports target and initiator modes
Supports Windows FDMI and WMI
Supports exclusive ATTO Advanced Data
Streaming (ADS) Technology
Host bus specifications
•
x8 mechanical and x8 electrical PCI Express
Interconnect
•
Conforms to PCI Express Base Spec 1.0a
3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-42ES Adapter
•
PCI Express to PCI/PCI-X Bridge spec 1.0
The Celerity FC-42ES is a dual-channel host adapter
providing port density for Enterprise server and
workstation applications. With 4-Gb FC speeds of up
to 800 MB/sec. per channel, the FC-42ES supports the
most demanding application requirements.
Environmental & physical specifications
•
•
Operating temperature: 0-45ºC (32º-113ºF)
Storage temperature: -40º to 70ºC (-40º to
158ºF)
•
•
•
Relative humidity: 5 to 95% non-condensing
100 lf/m (minimum) airflow recommended
Conforms to PCI half height, half length form-
factor specifications
12V@ 04A (max.); 3.3V @ 1.5A (max.)
Length: 5.6 inches
Additionally the FC-42ES takes advantage of the latest
in host interconnect technology, PCI Express, a serial,
high-speed connection that supports aggregate
throughput up to 4 GB/sec. (x8 PCIe) full-duplex. The
FC-42ES is software compatible with existing PCI and
PCI-X products using the same device drivers as other
Celerity FC family products, simplifying user
installation and support. It is backward compatible
with existing 2-Gb and 1-Gb Fibre Channel
•
•
•
•
Height: 2.712 inches
RoHS compliant
External connectivity
•
•
Easy-to-install full height connection plate
External LEDs for on-line and speed status for
each channel
2 pluggable optical LC SFP transceivers
included
infrastructure, protecting existing technology.
Hardware specifications
•
•
•
2 independent Fibre Channel ports
4-Gigabit data transfer rates per channel
800 MB/sec. maximum full-duplex throughput
per channel
•
Software specifications
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Mac OS X (10.4.x or later)
Red Hat Linux (2.4 and 2.6 kernel)
SUSE Linux (2.6 kernel)
•
•
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-AL, FC-AL2,
FC-FCP, FC-PLDA, FC-FLA
•
•
•
•
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
•
•
•
Supports target and initiator modes
Supports Windows FDMI and WMI
Supports exclusive ATTO Advanced Data
Streaming (ADS) Technology
Host bus specifications
•
x4 mechanical and x4 electrical PCI Express
interconnect (RoHS compliant)
•
•
Conforms to PCI Express Base Spec 1.0a
Conforms to PCI Express CEM Spec 1.0a
4
Celerity FC-41ES Adapter
The Celerity FC-41ES is a single-channel host adapter
providing support for the most demanding application
requirements. With 4-Gb FC speeds of up to 800
MB/sec. per channel, the FC-41ES is a cost effective
connectivity solution for environments requiring
maximum throughput.
Environmental & physical specifications
•
Conforms to PCIe low profile form factor
specifications
•
•
•
•
Length: 5.600 inches
Height: 2.712 inches
Operating temperature: 0-45ºC (32º-113ºF)
Storage temperature: -40º to 70ºC (-40º to
158ºF)
The FC-41ES also takes advantage of the latest in host
interconnect technology: PCI Express, a serial, high-
speed connection that supports aggregate throughput
up to 2 GB/sec. (x4 PCIe) full-duplex. The FC-41ES is
software compatible with existing PCI and PCI-X
products using the same device drivers as other
Celerity FC products, simplifying user installation and
support. It is backward compatible with existing 2-Gb
and 1-Gb Fibre Channel infrastructure, protecting
existing technology investments.
•
•
•
•
Relative humidity: 5 to 95% non-condensing
100 lf/m (minimum) airflow recommended
Power: 12V@ 0.4A max; 3.3V@1.0A max.
RoHS compliant
External connectivity
•
•
•
Easy-to-install full height connection bracket
External LEDs for on-line and speed status
Pluggable optical LC SFP transceiver included
Software specifications
Hardware specifications
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Red Hat Linux (2.4 and 2.6 kernel)
SUSE Linux (2.6 kernel)
•
•
•
•
1 Fibre Channel port
4-Gigabit FC data transfer rates
800 MB/sec. maximum full-duplex throughput
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-AL, FC-FCP,
FC-AL2, FC-PLDA, FC-FLA
Mac OS X (10.4.x or later)
•
•
•
•
•
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
•
•
•
Supports target and initiator modes
Supports Windows FDMI and WMI
Features exclusive Advanced Data Streaming
(ADS) Technology
Host bus specifications
•
•
•
x4 mechanical and x4 electrical PCI Express
interconnect
Supports PCI Express Base Spec 1.0a and
CEM Spec 1.0a
Supports PCI Express to PCI/PCI-X bridge spec
1.0
5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-42XS Adapter
•
•
•
Height: 2.536 inches
The dual-channel Celerity FC-42XS host adapter
provides the highest available throughput for Fibre
Channel applications while protecting technology
investments via backward compatibility with existing
infrastructure.
Operating temperature: 0-45ºC (32º-113ºF)
Storage temperature: -40º to 70ºC (-40º to
158ºF)
Relative humidity: 5 to 95% non-condensing
3.3V@ 1.5A (max.)
•
•
•
•
With speeds of up to 800 MB/sec. per channel, the FC-
42XS is capable of supporting the most intensive data
applications.
100 lf/m (minimum) airflow recommended
RoHS compliant
External connectivity
•
•
To ensure a smooth transition path, the FC-42XS
leverages the existing Celerity FC software hardware
architecture, allowing ATTO to deliver industry-
leading quality and stable software architecture.
Easy-to-install full height connection plate
External LEDs for on-line and speed status for
each channel
•
2 optical LC SFP transceivers included
Hardware specifications
Software specifications
•
•
•
2 independent Fibre Channel ports
4-Gigabit data transfer rates per channel
800 MB/sec. maximum full-duplex throughput
per channel
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Red Hat Linux (2.4 and 2.6 kernel)
SUSE Linux (2.6 kernel)
Mac OS X
•
•
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,
FC-AL2, FC-PLDA, FC-FLA
•
•
•
•
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
•
•
•
Supports target and initiator modes
Supports Windows FDMI and WMI
Includes exclusive ATTO Advanced Data
Streaming (ADS) Technology
PCI bus specifications
•
•
•
•
64-bit, 133 MHz PCI-X
PCI-X 1.0a compliant
PCI 2.2 compliant
3.3V PCI signaling only
Environmental & physical specifications
•
Conforms to PCI low profile form factor
standards
•
Length: 6.600 inches
6
Celerity FC-41XS Adapter
The single-channel Celerity FC-41XS provides speeds
of up to 800 MB/sec. using full 4-Gigabit Fibre
Channel performance while being fully backward-
compatible with existing 2-GB and 1-Gb Fibre
Channel infrastructure, protecting existing technology
investments. It is capable of supporting the most data-
intense applications.
Environmental & physical specifications
•
Conforms to PCI low profile form factor
standards
•
•
•
•
Length: 6.600 inches
Height: 2.536 inches
Operating temperature: 0-45ºC (32º-113ºF)
Storage temperature: -40º to 70ºC (-40º to
158ºF)
Hardware specifications
•
•
•
•
Relative humidity: 5 to 95% non-condensing
3.3V@ 1.5A (max.)
100 lf/m (minimum) airflow recommended
RoHS compliant
•
•
•
•
1 Fibre Channel port
4-Gigabit data transfer rates
800 MB/sec. maximum full-duplex throughput
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,
FC-AL2, FC-PLDA, FC-FLA
External connectivity
•
•
•
Easy-to-install full height connection plate
External LEDs for on-line and speed status
Optical LC SFP transceiver included
•
•
•
•
•
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes
Software specifications
•
•
•
•
Windows XP, 2000, Server 2003 and Vista
Red Hat Linux (2.4 and 2.6 kernel)
SUSE Linux (2.6 kernel)
Advanced FC capabilities
Mac OS X
•
•
Supports SNIA HBA API
On-demand automatic
negotiation among 4-Gb, 2-
Gb and 1-Gb Fibre Channel
Supports target and initiator
modes
Supports Windows FDMI and
WMI
Includes exclusive ATTO
Advanced Data Streaming
(ADS) Technology
•
•
•
PCI bus specifications
•
•
•
•
64-bit, 133 MHz PCI-X
PCI-X 1.0a compliant
PCI 2.2 compliant
3.3V PCI signaling only
7 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-21PS Adapter
•
Includes exclusive ATTO Advanced Data
Streaming (ADS) Technology
The Celerity FC-21PS Fibre Channel host adapter
provides a single 2-Gb Fibre Channel connection from
host devices to the Storage Area Network (SAN)
fabric.
PCI bus specifications
•
•
•
64-bit/32-bit, 66/33 MHz PCI compatible
PCI 2.3 compliant
3.3V and 5V PCI signaling with universal
connector
The FC-21PS supports the leading operating systems,
providing a single solution for all connectivity needs.
As with all Celerity FC products, the FC-21PS is
designed for high-quality data transmission, ensuring
that critical information is delivered correctly the first
time to reduce fabric traffic and improve overall fabric
efficiency.
Environmental & physical specifications
•
Conforms to PCI low profile form factor
standards
Length: 6.600 inches
•
•
•
•
Height: 2.536 inches
Hardware specifications
Operating temperature: 0-45ºC (32º-113ºF)
Storage temperature: -40º to 70ºC (-40º to
158ºF)
Relative humidity: 5 to 95% non-condensing
5V@ 1.5A (max.)
•
•
•
1 Fibre Channel port
400 MB/sec. throughput full-duplex
Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
Flash ROM for easy field upgrades
Simultaneous multi-protocol support
ANSI Fibre Channel: FC-PH, FC-FCP, FC-AL,
FC-AL2, FC-PLDA, FC-FLA, IETF-IPFC
•
•
•
•
•
•
100 lf/m (minimum) airflow recommended
External connectivity
•
•
•
Easy-to-install full height connection plate
Integrated optical LC SFF fixed transceiver
External LEDs for on-line and speed status
Advanced FC capabilities
•
•
Supports SNIA HBA API
On-demand, automatic negotiation between 2-
Gb and 1-Gb Fibre Channel
Software specifications
•
•
Supports target and initiator modes
Supports Windows FDMI and WMI
8
Celerity selection guide
Celerity
FC-42ES
FC-42EN
Celerity
FC-41ES
FC-41EN
Celerity
FC-44ES
Celerity
FC-42XS
Celerity
FC-41XS
Celerity
FC-21PS
Product Features
4
2
1
2
1
1
Fibre Channel Ports
FC protocol
4-Gb
4-Gb
4-Gb
4-Gb
4-Gb
2-Gb
Maximum Transfer Rate (half
duplex)
1.6 GB/sec
2 GB/sec
800 MB/sec
400 MB/sec
800 MB/sec
800 MB/sec
400 MB/sec
800 MB/sec
200 MB/sec
400 MB/sec
Maximum Transfer Rate (full-
duplex)
1 GB/sec (ES)
1.6 GB/sec (EN)
1
1 GB/sec
PCIe
8 lane
PCIe
4 lane
PCIe
4 lane
PCI-X
64-bit
PCI-X
64-bit
PCI-X
64-bit
Bus Type
3
Bus Characteristics
2
2
2
133 MHz
133 MHz
133 MHz
SFP LC
SFP LC
SFP LC
SFP LC
SFP LC
SFF LC
Optical Interface
300m@2-Gb
150m@4-Gb
300m@2-Gb
150m@4-Gb
300m@2-Gb
150m@4-Gb
300m@2-Gb
150m@4-Gb
300m@2-Gb
150m@4-Gb
500m@1-Gb
300m@2-Gb
Maximum Cable Length
Low Profile form factor
•
•
•
•
•
•
•
•
•
•
•
ATTO Advanced Data Streaming
(ADS) Technology
3
•
•
•
•
•
•
•
•
•
•
•
•
Software RAID support
Developer's Kit (Target Mode &
API)
•
•
•
•
•
•
Windows XP, 2000, Server 2003
and Vista support
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Linux (Red Hat, SUSE) driver
Macintosh OS X driver
Novell Netware support
Solaris support
Free BSD
RoHS compliant
1
2
3
Performance ceiling is constrained by 133 MHz PCI-X bus transfer speed
Backward compatible to 32-bit and 33 MHz PCI; FC-21PS is 3.3V/5V Universal
ATTO ExpressStripe for OS X available; Express Power Center and other software RAID supported for Windows
9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
10
2 Fibre Channel is a key technology for storage
Fibre Channel is a serial communications technology designed to transfer large amounts of data among
a variety of hardware systems over long distances. It is a key technology for applications that require
shared, high bandwidth access to storage.
Fibre Channel provides a logical, point-to-point,
serial channel for the transfer of data between a
buffer at a source device and a buffer at a
destination device. It moves buffer contents from
one port to another, without regard to the format
or meaning of the data so different upper level
protocols are able to run over Fibre Channel
hardware.
The Fibre Channel architecture is structured as a
hierarchical set of protocol layers. Defined within
these layers are rules for signal interfaces, serial
encoding and decoding, error control, frame
format and communications protocols.
Glossary
Some terms used in the Fibre Channel industry are defined below. More information is available through
.
Term
Definition
ANSI
American National Standards Institute
arbitrate
process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop
at the same time
arbitrated loop
a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can
communicate at one time; low-cost solution which may or may not use hubs and switches
auto negotiation
hardware senses and automatically responds depending on configuration
BER
bit
Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent
smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1
bus
a collection of unbroken signal lines used to transmit information from one part of a computer
system to another; taps on the lines connect devices to the bus
byte
an ordered set of 8 bits
channel
CPU
a point-to-point link which transports data from one point to another
Central Processing Unit: the portion of the computer that actually performs computations
CRC
Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received
and transmitted data; if no error has occurred during transmission, the CRC for both received and
transmitted data should be the same
destination
address
a value in the frame header of each frame which identifies the port in the node where the frame is
being sent
device driver
DMA
a program that allows a microprocessor to direct the operation of a peripheral device
Direct Memory Access: a way to move data from a storage device directly to RAM without using
the CPU’s resources
DMA bus master allows a peripheral to control the flow of data to and from system memory by block as opposed to
allowing the processor to control the data by bytes (PIO or programmed I/O)
11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Term
Definition
fabric
a Fibre Channel switch of two or more Fibre Channel switches interconnected to physically
transmit data between any two N_Ports on the switch or switches
FC
Fibre Channel
F_port
a port in the Fibre Channel fabric where a N_port may attach
a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop
an indivisible unit for transfer of information in Fibre Channel
FL_port
frame
frame header
full-duplex
half duplex
the first field in the frame containing the address and other control information about the frame
a communication protocol which allows transmission in both directions at the same time
a communication protocol which allows transmission in both directions, but only one direction at a
time
host
a processor, usually a CPU and memory, which communicates with devices over an interface
a component which originates a command
initiator device
L_port
a port in an arbitrated loop, either a NL_port or a FL_port
LED
Light-emitting diode: a type of diode that emits light when current passes through it; visible LEDs
are used as indicator lights on all sorts of electronic devices
LUN
Logical Unit Number: an identifier for a logical unit (0-7)
multi-mode fiber an optical fiber which can carry several beams of light at once
N_port
a port attached to a node used with point to point or fabric configurations
a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration
an initiating device; a component which originates a command
NL_ port
originator
parity checking
a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in
the transfer to make the sum of all the bits either odd or even (for odd or even parity); an error
message occurs if the sum is not correct
PCI
Peripheral Component Interconnect. Allows peripherals to be connected directly to computer
memory, bypassing the slower ISA and EISA busses
point-to-point
port
a topology where two ports communicate
an access point in a device: see N_port, NL_port, etc.
port address
also port number; the address, assigned by the PCI bus, through which commands are sent to a
host adapter board
port number
receiver
see port address
the ultimate destination of data transmission; a terminal device
scatter/gather
a device driver feature which allows the host adapter to modify a transfer data pointer so that a
single host adapter can access many segments of memory, minimizing interrupts and transfer
overhead
SCSI
Small Computer Systems Interface: a processor-independent standard for system-level interface
between a computer and intelligent devices including hard disks, floppy disks, CD-ROM, printers,
scanners, etc.
single-mode fiber an optical fiber with a small core which supports one wavelength (ray of light); the core radius is
nearly equal to the wavelength of the source
topology
logical layout of the parts of a computer system or network and their interconnections
a transmitter/receiver module
transceiver
transfer rate
the rate at which bytes or bits are transferred, as in megabytes or gigabits per second
12
3 Installing and updating drivers
Before installing your Celerity adapter, you must configure your system to recognize and use it by
installing drivers for your operating system.
Configure your system to recognize and use your
Celerity adapter by
ATTO Celerity adapters ship with the latest
firmware installed.
•
•
installing drivers for your operating system
updating the adapter firmware if necessary (refer
The Celerity FC Installation CD shipped with
your adapter contains the latest driver.
The Installation CD automatically starts when
inserted in the system CD-ROM drive. Navigate
the easy-to-use HTML-based menu to find the
driver that you want to install.
Note
If you already have one or more Celerity
adapters installed and you are installing
additional adapter(s), you do not need to
perform any of these procedures unless you
are updating a previously installed driver.
If the CD does not automatically start, open the
CD and click on autorun.bat
.
Specialized configurations
Some specialized applications may benefit from
modification of adapter settings. The ATTO
Utilities Installation and Operation Manual
provides detailed information on using ATTO
Technology configuration utilities found on the
ATTO Utilities CD or downloaded from the
ATTO website. For best performance, use the
most recent device driver and flash version.
Note
Windows NT is only supported with Celerity
driver version 1.31 or earlier. If you are using
Windows NT, contact your service
representative.
Mac OS X: Use the ATTO Configuration Tool on
the ATTO Utilities CD, or download it from
www.attotech.com, or use the Apple System
Profiler.
Verify the version based on your operating
system.
Linux: Use the ATTO Configuration Tool on the
ATTO Utilities CD, or download it from
www.attotech.com, or to find the driver version,
examine /proc/scsi/celerityfc/X, where
adapter’s host number.
Windows: Use the ATTO Configuration Tool
from the ATTO Utilities CD, or download it from
www.attotech.com, or view the adapter boot
string during system boot or look in the Device
X
is the
Manager
.
Windows 2000/XP/Server 2003/Vista
Five procedures are described below. Review
each thoroughly to ensure that you are using the
one that best fits your needs. If you have one or
more Celerity FC adapters installed in your
system and you are installing additional
these procedures unless you are updating a
previously installed driver.
The Celerity FC Installation Disk can be the
Installation CD shipped with your adapter, a
folder containing the latest downloaded and
expanded driver, or a Celerity FC installation
floppy disk.
adapter(s), you do not need to perform any of
13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
the wizard default settings to complete the
installation.
Upgrading an existing Celerity FC driver
1
2
3
4
Log on to Windows as the System
Administrator.
Creating a boot disk
Insert your Celerity FC Installation Disk and run
autorun.bat
Note
In Windows Drivers, select your operating
system version.
The procedure described below does not
apply to Windows Server 2003 for Itanium
systems because the Celerity FC driver does
not support boot functionality on Itanium
systems.
Click on Install Driver.
Adding a Celerity FC adapter to an
existing installation
1
2
Start Windows text mode setup as found in the
instructions provided with Windows.
Note
Press F6 when Windows Setup, displays. The
setup program displays a prompt in the status
window on the bottom left of the monitor. Setup
continues to load files after you press F6.
Complete this installation procedure before
attaching any devices to the adapter.
1
2
3
Complete the steps in Updating hardware flash
on page 24 to pre-install the driver.
3
A new window displays instructions to specify
additional mass storage devices. Press S to
install the ATTO Celerity as a storage device.
Close Windows and turn off power to your PC
when Setup prompts you to do so.
4
5
6
Insert the Celerity FC installation diskette in
drive A and press Enter.
Install your new Celerity FC adapter into an
available PCI expansion slot.
a. If the Celerity FC adapter is replacing
another adapter in the system, disconnect
the FC cables from the adapter and
remove the adapter from the system, or
move the Celerity FC adapter to the PCI
slot that the previous adapter occupied.
b. Attach the appropriate FC cables to the
Celerity FC adapter.
A screen displays a list of Celerity FC adapters.
Select your adapter and press Enter.
Windows Setup loads the files from the floppy
and then displays the screen described in Step
2. The ATTO Celerity FC device should now be
listed as detected.
7
8
supplied driver installation disks.
4
5
6
Close the computer chassis
After all other drivers have been processed,
press Enter and proceed with the rest of the
Windows installation procedure.
Turn on the power and restart Windows.
During the boot process, Windows detects your
Celerity FC adapter and the Found New
Hardware Wizard is displayed.
Note
When Windows begins copying files to your
hard disk, a display prompts you to insert the
Celerity FC installation disk and any other
vendor-supplied disks you used during
custom installation. This is normal. The first
time you inserted the disks, Windows loads
the drivers into memory; the second time you
insert the disk(s), Windows copies the driver
to your hard disk.
Follow the directions in the Found New
Hardware Wizard, selecting the default
settings for each adapter channel.
7
8
Insert the Celerity FC Installation disk when
asked to do so.
When adapter installation is complete, the
Found New Hardware Wizard displays an
ATTO Phantom Device for each channel. Use
14
Creating a Celerity FC installation floppy
Creating a floppy disk from a download
1
Download the latest driver software from the
The download is a self-extracting executable
that expands the driver software package. Run
the self-extracting executable and select a
folder to place the expanded software package.
Note
You must have a floppy disk with the Celerity
FC driver software to install a fresh copy of
the Windows OS onto a disk attached to a
Celerity FC adapter.
2
1
Insert the Installation CD into a CD-ROM. The
installation starts automatically.
3
Navigate to the folder with the desired Celerity
FC driver.
If the Celerity FC installation does not start,
navigate to the root of the CD and run
autorun.bat
Note
The expanded software package contains a
Miniport driver and may contain a StorPort
driver. The Celerity FC Windows Miniport
driver is in the base directory of the
expanded software package. The Celerity
FC Windows StorPort driver is in the
StorPort subdirectory.
2
3
4
Select Windows Drivers from the items on the
left side of the screen.
Select the appropriate CPU-based operating
system from operating system choices.
Select Create Miniport Driver Diskette or
Create StorPort Driver Diskette for the
desired operating system.
4
Run makedisk.bat and follow the instructions
for creating the floppy disk.
5
Follow the instructions for creating the floppy
disk.
Mac OS X driver installation, update
1
Extract the latest version of the device driver file
to your desktop.
3
Reboot your system for the changes to take
effect.
2
Double click the installer icon and follow the on
screen prompts.
Linux driver installation, update
2
3
4
Download the appropriate version of the device
driver from the ATTO website.
Note
You must have kernel header files for the
appropriate kernel installed.
At the command prompt, extract the file using
the command tar -xfz <filename.tgz>
You must be logged in as root
.
Enter the directory created in the above step
and type make install to overwrite any
previously-installed driver.
1
At the command prompt type rmmod
celerityfc
5
Start the driver by typing modprobe celerityfc
15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
16
4 Hardware installation
You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please
refer to Fibre Channel is a key technology for storage on page 11 for a list of related websites.
WWN 0 all adapters
CAUTION
WWN 1: 44ES, 42ES, 42XS, 42EN
Back up your system data before changing
or installing any hardware.
WWN 2 44ES
WWN 3 44ES
System requirements
Installation
The Celerity FC host adapter package contains the
host adapter, the ATTO Utilities CD and a
CAUTION
Celerity FC host adapters contain
components that are sensitive to
electrostatic discharge (ESD). ESD can
cause damage to the Celerity FC host
adapter. Please follow standard methods to
avoid ESD.
warranty and registration card. If any of these
items are missing, contact your ATTO authorized
sales representative.
To install and use the Celerity Fibre Channel host
adapter you need
•
A computer with an available PCI, PCI-X or PCI
Express expansion slot
1
2
Install the latest drivers. Refer to Installing and
•
The complete Celerity FC host adapter package
Power down the computer and unplug the
computer from all power sources.
Fibre Channel address
3
4
Open the case.
Install the Celerity FC host adapter in any open
PCI, PCI-X or PCI Express expansion slot. If
you have questions about how to install an
expansion card in your system, consult your
computer’s documentation.
Celerity FC adapters are configured with a unique
address designated by the Institute of Electrical
and Electronic Engineers. The WorldWide Port
Name (WWN) and Node Name are the two
components of the address assigned to Fibre
Channel products. This address, stored in flash
memory, allows the system to recognize the
Celerity host adapter as a unique part of your
configuration. The address is clearly marked on
the back of the board for easy identification.
Please keep a reference copy of the number in a
safe place or write in the space provided on this
page.
Drawings of Celerity brackets begin on page 18
Note
The Celerity FC-41XS, and FC-42XS host
adapters only fit in 3.3V slots.
The Celerity FC-42ES, FC-41ES, FC-41EN
and FC-42EN fit into x4, x8, or x16 mechanical
PCI Express slots.
If you have trouble seating your adapter in a 32-
bit PCI bus computer, check to make sure the
connector can accommodate 64-bit host
adapters.
Celerity FC host adapter WWNs are assigned for
each channel. The WWN listed on your host
adapter is assigned to the first channel (0).
Sequential WWNs apply for additional channels.
5
6
Connect Fibre Channel devices by inserting a
Fibre Channel cable from the devices to the
connectors on the Celerity FC host adapter until
you hear a click.
Close the case on the computer and power it
up.
17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Exhibit 4-5 FC-41ES low profile and full height
adapters
Exhibit 4-7 FC-41XS low profile and full height
adapters
Exhibit 4-8 FC-21PS Adapter
Exhibit 4-6 FC-42XS low profile and full height
adapters
19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Exhibit 4-11 FC-44ES
Exhibit 4-12 FC-42ES
21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Exhibit 4-13 FC-41ES
Exhibit 4-14 FC-42XS
22
Exhibit 4-15 FC-41XS
Exhibit 4-16 FC-21PS
23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
5 Updating hardware flash
Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be
updated as new versions become available or if the factory-installed version becomes corrupt. Visit the
2
The download is a self-extracting executable
that expands the driver software package. Run
the self-extracting executable and select a
folder in which to place the expanded software
package.
Hardware flash memory may need to be updated
as new versions become available or if the
factory-installed version becomes corrupt.
Updating flash in all operating systems
The expanded software package contains a
Miniport driver and may contain a StorPort
driver. The Celerity FC Windows Miniport driver
is in the base directory of the expanded
software package. The Celerity FC Windows
StorPort driver is in the StorPort subdirectory.
1
Download the most recent version of the
Configuration Tool from the ATTO website.
Refer to the ATTO Utilities Installation and
Operation Manual for additional information on
downloading and using the Configuration Tool.
2
Download the proper flash bundle (adapter
specific) from the ATTO website.
3
4
Navigate to the folder with the desired Celerity
FC driver.
3
4
5
6
Extract these files to your desktop.
Run makedisk.bat and follow the instructions
for creating the floppy disk.
Install the Configuration Tool on your system.
Launch the Configuration Tool.
Note
In the Device window, select the adapter that
needs to be updated.
The flash update must be loaded from a
floppy because CD-ROM drivers are not
loaded at this point in the system boot
process.
7
In the Flash window, click on the Browse
button to find the flash bundle that you
previously downloaded to your desktop.
5
6
Reboot the PC.
8
9
Click Update to update your flash ROM.
During the reboot, an ATTO Technology
banner displays that the host adapter was
detected.
Reboot your system for the changes to take
effect.
7
Enter Control-F when prompted to begin the
set-up utility within a few seconds after the
banner appears.
Updating flash on a PC
You may update hardware flash on a PC using
BIOS utilities.
If you do not enter Control-F soon enough after
the banner appears, repeat steps 5 and 6.
Note
8
9
In the utility, select the Upgrade Flash ROM
option.
BIOS utilities do not work on Itanium
systems. Use the ATTO Configuration Tool
to update flash on Itanium systems.
Insert the disk into the drive slot.
10 Follow the on-screen instructions.
1
Download the latest driver software from the
ATTO Technology website.
11 Remove the disk and reboot your system for
the flash ROM changes to take effect
24
6 Troubleshooting
This chapter contains solutions for the most common problems you might encounter. If you need
authorized ATTO Technology representative.
•
Check that Fibre Channel devices are plugged
into an AC outlet and are turned on before you
add power to your computer.
General suggestions
•
•
Check each cable connection on every device.
Verify all cables are in proper working condition.
Loose or broken cables are often the cause of
errors or problems.
Mac OS X
3
Verify the driver is loaded.
Note
a. Click on the adapter name in the
Device Listing to view the Basic Info
screen.
The Celerity FC supports Mac OS X versions
10.3 and later.
b. If the Driver Information section
indicates Unknown: driver not
loaded, reinstall the driver. Refer to
13.
c. If reinstalling the driver does not fix the
problem, contact an authorized ATTO
representative.
1
2
Open the ATTO Configuration Tool from the
ATTO Utilities CD or download from the ATTO
website. Refer to the ATTO Utilities Installation
and Operation Manual for additional
information.
If the adapter does not appear in the Device
Listing, make sure it is properly seated in the
PCI slot.
4
Reset the NVRAM for all channels to defaults
and reboot. If the problem persists, contact an
authorized ATTO representative.
a. Remove power from the PC.
b. Remove the case.
c. Check the PCI slot.
d. Replace the case.
e. Apply power.
Note
When calling ATTO Technical Support,
please have a printout of the IOreg listing
and output from the Apple System Profiler
available.
Note
If the Celerity adapter is properly seated and
devices are still not accessible, contact an
authorized ATTO representative.
Windows 2000/XP/Server 2003/Vista
•
If the card has been recently re-flashed, the new
Windows driver must be installed. Follow the
•
•
•
Procedures vary greatly: refer to the manual
supplied with your system or call the computer
supplier for configuration assistance.
Windows 2000/XP/Server 2003/Vista are Plug-
n-Play operating systems: be sure your
computer’s BIOS is set accordingly.
•
All of the external devices connected to the host
adapter should be identified. If they do not
appear in the Device Manager, the external
devices or connection may not be working
properly.
If these do not solve the problem, re-flash the
host adapter and re-install the Windows
2000/XP/Server 2003/Vista driver. See
•
For Intel-based PCs, check the computer CMOS
setup and verify that the PCI slots are configured
correctly.
25 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
•
If the adapter has been identified but there is an
exclamation point (!) on the listing, right click on
the listing and select Uninstall.
If the devices connected to the Celerity FC host
adapter are not accessible
1
2
3
4
•
Right-click My Computer.
Select Properties.
5
6
7
Reload the driver (see Installing and updating
Select the Hardware tab.
Select Device Manager.
Reboot the system and repeat the installation
process.
If the Celerity FC host adapter does not appear
under the SCSI and RAID controllers, remove
power from the PC, open the case, and check
that the Celerity FC adapter is properly seated in
the PCI slot. Replace the case and apply power.
If problems persist, contact your authorized
ATTO Technology representative.
Linux
1
Verify the celerityfc driver is loaded with the
3
Examine the contents of the file(s)
/proc/scsi/celerityfc/X, where X is the
adapter’s host number. This file contains details
such as link status, connection speed and
discovered devices.
lsmod command. If lsmod does not show the
driver, refer to the installation instructions to
install and load the driver in Installing and
2
Check the system log with the command
dmesg. The celerityfc driver creates status
messages during initialization. Make sure that
all installed cards are properly detected and
initialized.
Note
Advanced users only. Modify the driver
makefile to enable debugging information.
Upon loading, the celerityfc driverdisplays
detailed debugging information which may
help troubleshoot the problem.
26
Appendix A Standards and compliances
The equipment described in this manual generates and uses radio frequency energy. The Technical
Specification sheet for a particular Celerity FC host adapter list certifications for that model.
FCC standards: radio and television interference
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
•
•
•
•
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Canadian standards
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
European standards
Declaration of Conformity
This following statement applies to the Celerity FC host adapter.
This device has been tested in the basic operating configuration and found to be compliant with the
following European Union standards: Application of Council Directive: 89/336/EEC
Standard(s) to which conformity is declared: EN55024:2002; EN55022:2002 CLASS B
This Declaration will only be valid when this product is used in conjunction with other CE approved
devices and when the entire system is tested to the applicable CE standards and found to be compliant.
Some ATTO Celerity cards comply with Directive 2002/95/EC on the Restriction of
the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS).
Contact your ATTO representative regarding RoHS compliant products.
i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Usage restrictions
The use of optical instruments with this product will increase eye hazard.
The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR
1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum
ratings. The laser is non-OFC compliant as it is a Class 1 device.
The optical ports of the modules must be terminated with an optical connector or with a dust plug.
CAUTION
Failure to adhere to the above restrictions could result in a modification that is considered an act of
“manufacturing” and will require, under law, recertification of the modified product with the U.S. Food
and Drug Administration (ref. 21 CFR 1040.10(i)).
The following apply to the Celerity FC-42XS host adapter only
This is a Class B product based on the standard of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a
domestic environment, it may cause radio interference. Install and use the equipment according to the
instruction manual.
ii
Appendix B Accessories
The following Fibre Channel accessories are available through ATTO Technology and authorized
resellers. Contact an ATTO Technology authorized sales representative to order.
Optical Cables
CBL-FCFI-05x
CBL-LCSC-003
CBL-LCSC-010
5 m. cable– Duplex 50 Micron Multi-mode FC/Optical
3 m. 50/125 optical cable (LC to SC)
10 m. 50/125 optical cable (LC to SC)
A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology.
Please contact your ATTO sales representative for product descriptions and part number information.
Fibre Channel and iSCSI solutions
TM
ATTO FibreBridge
ATTO iPBridge
Fibre Channel-to-SCSI bridge
iSCSI to SCSI, iSCSI to Fibre Channel bridges
SCSI solutions
ATTO ExpressPCI Family of SCSI Host Adapters (see Appendix C)
SAS/SATA Solutions
ATTO ExpressSAS family of SAS Adapters (see Appendix D)
Software
ATTO Utilities
ATTO ExpressStripe
Configuration and management software
Mac OS X RAID and benchmark software
ATTO Express Power CenterWindows-based striping utility
iii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Appendix C SCSI adapter selection guide
Ultra 320 SCSI
Product Features
UL5D
640
UL5D LP
640
UL4D
640
UL4S
320
Max. transfer rate (MB/sec.)
Low Voltage Differential
•
•
•
•
Single-ended SCSI
•
•
0/2
30
•
•
•
Number of SCSI Channels
Number of SCSI IDs supported
Low profile
2/2
30
2/2
30
1/1
30
Large file transfers
•
•
•
•
Cable distances (m)
32-bit PCI compatible
12.5
12.5
12.5
12.5
•
•
•
•
•
•
•
•
•
•
64-bit PCI compatible
33 MHZ PCI
133 MHZ PCI-X
66 MHz PCI
x4 PCI Express
•
•
•
•
•
•
•
•
•
•
•
•
Windows 2000/XP, Server 2003/Vista support
Linux support
•
•
•
•
•
•
•
•
•
•
Mac OS X support
Novell Netware support
RoHS compliant
iv
Appendix D SAS adapter selection guide
ATTO ExpressSAS RAID Adapters
Product Features
R348
R380
1
Max.transfer rate (full duplex)
4 GB/sec.
4 GB/sec.
x8 PCI Express
Number of ports
•
•
8
8
Port configuration
external/internal
4/8
8/0
user selectable 4/4 or 0/8
Connector type
1 mini SAS (x4) SFF-8088 external 2 mini SAS (x4) SFF-8088 external
2 mini SAS (x4) SFF-8087 internal
Number of devices supported
64 SAS/SATA targets
128 virtual devices
64 SAS/SATA targets
128 virtual devices
1.5 Gb SATA support
3 Gb SATA II support
3 Gb SAS support
•
•
•
•
•
•
Cable distances
Integrated RAID
up to 8m
up to 8m
2
2
2
2
0, 1, 4, 5, 6 , 10, 50, 60 , JBOD,
DVRAID
0, 1, 4, 5, 6 , 10, 50, 60 , JBOD,
DVRAID
RAID Management Utility
Global Hot Spares
•
•
•
•
Event notification
Memory (ECC)
E-mail, pop-up, log file
E-mail, pop-up, log file
258 MB standard
258 MB standard
512 upgradeable (OEM)
512 upgradeable (OEM)
Advanced Data Streaming™
•
•
Battery backup
32-bit support
optional
optional
•
•
•
•
•
•
64-bit support
Windows 2000/CP, Server
2003/Vista support
Linux (Red Hat, SUSE) support
Mac OS X support
•
•
•
•
•
•
•
•
RoHS compliant
Low profile
1
Performance ceiling constrained by PCIe bus transfer speed
Future support
2
v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Appendix E Contact ATTO Technology, Inc.
Customer service, sales information and technical support are available by phone Monday through Friday,
Eastern Standard Time 8:00 a.m. to 8:00 p.m., or by e-mail and website 24-hours a day.
ATTO Technology, Inc.
155 CrossPoint Parkway
Amherst, New York 14068
(716) 691-1999 • voice
(716) 691-9353 • fax
ATTO Technology can also be reached via e-mail at the following addresses:
Sales Support:
Technical Support:
vi
|
Hood 2520 User Manual
Haier HTAF21B User Manual
Electrolux E36IC75FSS User Manual
Eizo LA 120 D User Manual
Cypress enCoRe CY7C604XX User Manual
Cypress CY7C1380DV25 User Manual
Cypress CY7C024BV User Manual
Blue Sea Systems BLUE SEAL EVOLUTION G518D LS User Manual
Asus P4BGV MX User Manual
Asus Motherboard 90MB0DR0M0AAY0 User Manual