NOTICE
Every effort was made to ensure that the information in this manual was complete and accurate at the
time of printing. However, information is subject to change.
COMPATIBILITY
The AT&T Door Phone Controller is recommended for use with any AT&T business telephone system.
It is also intended to be used with the AT&T Door Phone Speaker.
WARRANTY INFORMATION
Partner, Spirit, Merlin, System, Dimension, Horizon, Touch-Tone and Comkey are registered trademarks
of AT&T.
VG
ii
Application Notes (for Compatibility Chart)
1. When used in any mode of a System 25, if the user initi-
ates a call to the door and he wishes to enter the
Option Selection mode, pressing three pound keys fol-
lowed by the digit 3 (i.e., # # # 3, not # # 3) must be
entered. Actually, the first # does not seem to be recog-
nized at any time during the call. However, it should be
noted that only # # 3 is needed to enter the Option Se-
lection mode when the call is initiated from the door
button press.
When sharing a trunk port on a System 25, that port
must be configured as an “805” PBX/Centrex, not an
“801” Loop trunk. This is the only way to transmit a
hook flash to that port.
2.
3. On the Merlin 1030/3070 tip and ring station application,
there is a preset delay such that the Merlin system will
disregard DTMF for the first 12 seconds of the connec-
tion. In this mode, users have the choice of either
changing that time period or waiting for it to time out for
each call.
4. In general, the ring-cadence option selection applies
only if there is an auxiliary alert device connected. All
of the EKTS/PBX’s will “absorb” the ringing signal from
the AT&T Door Phone Controller and generate their
own ring cadence to the telephone sets.
When using the AT&T Door Phone Controller in any con-
figuration with a Merlin System, the pound key must be
pressed twice (##) for each pound (#) sent to the unit
when dialing from a multi-button set.
5.
Port Saver/Trunk Saver operation will not work for
Tip/Ring sets. A switch-hook flash is not passed to the
trunk port from these sets.
6.
7. A trunk shared with the AT&T Door Phone Controller
should not be placed in a trunk pool with other trunks.
When the AT&T Door Phone Controller shares a C.O.
trunk, Trunk Saver operation is recommended.
8.
iv
Application Notes (for Compatibility Chart) continued
Tip/Ring telephone sets connected to the Merlin System
through a BTMI cannot use Port Saver/ Trunk Saver op-
eration. The BTMI wiII not transmit the required
hook-flash signal.
9.
10.
System 75 requires a pound (#) to be dialed at the end
of every dial string. This is required to send the dialed
number to the trunk port.
11. Tip/Ring telephone sets cannot be used in this mode to
access the AT&T Door Phone.
12. For PARTNER telephone sets not equipped with a Re-
call button, “FEATURE 03” must be dialed to send a
hook-flash signal to the trunk port.
13.
In the Ringdown mode, no number should be pro-
grammed in the AT&T Door Phone for it to dial when
the door button is pressed. The PARTNER Plus system
should be programmed to alert the desired stations
when the door phone goes off-hook on its station port.
14.
The information for this system is based on engineering
judgment.
v
Contents
1
2
3
vii
4
5
6
7
viii
Figures
1
2
3
x
4
5
6
D
E
xi
Tables
3
4
5
6
7
xii
Using This Manual
This manual will help you install, program and operate the
AT&T Door Phone Controller. It contains important information
on what features are available and how to use them. We urge
you to read this manual prior to installing the AT&T Door
Phone Controller; this will ensure that you are using the
product to its fullest capability.
Section 1 (this section) provides basic information on what the
AT&T Door Phone Controller is and what are its features. Also
included is a GIossary of Terms, a necessity for persons not
familiar with telephone equipment operation and installation.
Section 2, Installation, provides important installation
information. This section has step-by-step procedures for
connecting the AT&T Door Phone Controller to such optional
equipment as
■
■
■
■
Remote door unlocking devices
Door ajar switch
Auxiliary alert device
Remote open button
Section 2 also provides an easy to use flow chart, which directs
the installer to the next appropriate section, depending on what
type of telephone equipment (residential, PBX, etc.) will be
used along with your AT&T Door Phone Controller.
chart at the end of that section, the installer is referred to one
of these sections. Depending on which section is referenced,
all the necessary programming, switch setting and operating
information will also be included.
Section 7 provides troubleshooting tips for when installation is
complete and the AT&T Door Phone Controller is not operating
correctly.
Tear-out Reference Card at the end of this manual provides
all the necessary option selection information along with
complete DIP switch settings and their definitions.
1-2
Introduction
The AT&T Door Phone Controller
The AT&T Door Phone Controller provides multi-functional
control for communications to a dedicated door-speaker unit
and a remote door-unlocking device. The AT&T Door Phone
used along with a PBX (Private Branch Exchange) or
communications system to alert personnel within a residence or
building that someone is requesting attention at the entrance.
Operating the unit is simple: when the push button on the door
speaker is pressed, the AT&T Door Phone Controller unit
signals a telephone station(s) and can activate an auxiliary
alerting device (such as a door bell, chime, or tone generator)
within the home or building. Upon hearing the ringing telephone
and/or alerting device, answer the phone and have a two-way
phone conversation with the person at the door. The person
inside the building can also remotely unlock the door, either by
entering a numeric code (Door Code) on the telephone’s
touch-tone keypad, or by pressing a button.
Features
■ Control for remote door unlocking
■ Voice communications with door speaker
■ Door ajar detect
■ Interface for door bell, chime, or tone generator
■ Selectable option functions (from touch tone telephone)
Introduction
1-3
Terms You Should Know
—A door speaker’s push button can activate a
AuxiliaryAlert
bell/chime within the building.
Cadence —Telephone Ringing cycle, i.e., 2 second ringing,
4 second no ringing.
C.O. line —Central Office telephone line carrier into building.
EKTS (Electronic Key Telephone System) —Small business
telephone communications system.
Ground Start —One method by which a business telephone
system (PBX) signals the telephone company that you have
gone off-hook. Used in most business applications – contact
your telephone company to determine if you have Ground or
Loop Start.
Loop Start —One method of signaling the telephone company
that your telephone has gone off-hook – used for most
residential and communication system applications. Contact
your telephone company to determine if you have Ground or
Loop Start.
PBX (Private Branch Exchange) —Business telephone
system.
—In Station mode, the activation of the door
Ringdown
speaker’s push button will cause the AT&T Door Phone
Controller to dial the number of a predetermined telephone
station number (PBX or EKTS must be installed). When the
telephone is answered, there is direct two-way communication
with the door speaker.
Trunk Port —PBX connection for Central Office or trunk lines.
Station Port —PBX connection for station sets.
Hook-Flash —This causes telephone equipment to go “on
hook” for a duration usually less than a second (not long
enough to be considered as calling for the circuit to be
released.)
Introduction
1-5
2-2 Installation Procedures
Important Safety Instructions
When using your telephone equipment, basic safety
precautions should always be followed to reduce the risk of fire,
electric shock and injury to persons, including the following:
Read and understand all instructions.
1.
2. Follow all warnings and instructions marked on the
product.
3. Unplug this product from the wall outlet before cleaning.
Do not use liquid cleaners or aerosol cleaners. Use a
damp cloth for cleaning.
4.
Do not use this product near water, for example, near a
bath tub, wash bowl, kitchen sink, or laundry tub, in a
wet basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or
table. The product may fall, causing serious damage to
the product.
6.
Slots and openings in the cabinet and the back or bot-
tom are provided for ventilation. To avoid overheating,
these openings must not be blocked or covered. The
openings should never be blocked by placing the
product on the bed, sofa, rug, or other similar surface.
This product should never be placed near or over a
radiator or heat register. This product should not be
placed in a built-in installation unless proper ventilation
is provided.
This product should be operated only from the type of
power source indicated on the marking label. If you are
not sure of the type of power supply to your home, con-
sult your dealer or local power company.
7.
Installation Procedures
2-3
WARNING: RISK OF ELECTRICAL SHOCK –
EQUIPMENT MUST BE PROPERLY GROUNDED.
Your AT&T equipment requires a properly grounded
three-prong power receptacle for safe operation. Have
the receptacle checked by a qualified electrician before
connecting this equipment. Do not cut or remove the
third (ground) prong from the power transformer. Do
not use two-prong extension cords or adapters to
defeat the safety features of this equipment. If you
have a two-prong receptacle, it must be replaced with
a three-prong receptacle, installed by a qualified
electrician.
8.
9. Do not allow anything to rest on the power cord. Do not
locate this product where the cord will be abused by per-
sons walking on it.
10. Do not overload wall outlets and extension cords as this
can result in the risk of fire or electric shock.
11.
Never push objects of any kind into this product through
cabinet slots as they may touch dangerous voltage
points or short out parts that could result in a risk of fire
or electric shock. Never spill liquid of any kind on the
product.
12. To reduce the risk of electric shock, do not disassemble
this product, but take it to a qualified serviceman when
some service or repair work is required. Opening or
removing covers may expose you to dangerous voltages
or other risks. Incorrect reassembly can cause electric
shock when the appliance is subsequently used.
13. Unplug this product from the wall outlet and refer servic-
ing to qualified service personnel under the following
conditions:
A. When the power supply cord or plug is damaged or
frayed.
B. If liquid has been spilled into the product.
2-4
Installation Procedures
C. If the product has been exposed to rain or water.
D. If the product does not operate normally by following
the operating instructions. Adjust only those controls
that are covered by the operating instructions, because
improper adjustment of other controls may result in
damage and will often require extensive work by a
qualified technician to restore the product to normal
operation.
E. If the product has been dropped or the cabinet has
been damaged.
F. If the product exhibits a distinct change in performance.
14. Avoid using a telephone (other than a cordless type)
during an electrical storm. There may be a remote risk
of electric shock from lightning.
15. Do not use the telephone to report a gas leak in the
vicinity of the leak.
SAVE THESE INSTRUCTIONS.
General Information
Please adhere to the following precautions:
1. Never install telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the
jack is specifically designed for wet locations.
3. Never touch uninsulated telephone wires or terminals un-
less the telephone line has been disconnected at the
network interface.
4. Use caution when installing or modifying telephone lines.
Installation Procedures
2-5
Introduction
This section provides instructions for installing your AT&T Door
Phone Controller. Provided are installation instructions for an
optional electric door strike plate, door ajar contacts, and an
auxiliary alert device. These optional components must be
installed prior to the installation of your AT&T Door Phone
Controller. (Refer to the respective installation manuals for
specific mounting and wiring instructions.) The flow-chart
appropriate section for attaching the AT&T Door Phone
Controller to the telephone equipment in your home or
Contact a licensed electrician
for installation of optional
devices such as an electric
strike plate and auxiliary alert
device which may require
electrical wiring. For the electric
strikeplate, a low voltage device
(24 volts or less) is
recommended.
Inside the AT&T Door Phone Controller shipping carton
you will find:
■ The AT&T Door Phone Controller unit
■ Mounting template (along the edge of the Tear-out
Reference Card)
■ Power cord and attached transformer
■ Two mounting screws
■ Two 6-conductor modular-to-modular 6 foot long cables
■ Terminal strip connector
■ Instruction Manual (this manual)
Door Phone Controller Back Panel Connections
has two RJ11 modular connectors and one 14-contact “hard
wire” terminal strip. These connections provide:
The 14-contact terminal strip
can be unplugged from the back
panel.
■ Auxiliary Alert Contacts (2) – output to optional door
bell/chime device.
■ Door Latch Contacts (3) – output to an electric door strike.
■ Remote Open Button Contacts (2) – input from a remote
(inside) door open button.
2-6
Installation Procedures
■ Door Ajar Switch Contacts (2) – input from door ajar device.
■ Door Bell Button Contacts (2) – input from door bell/chime
button.
■ Shield Contact (1) – used for shielding audio speaker wires.
■ Speaker Contacts (2) – provides audio connection to door
speaker(s).
Host system RJ11 (J1 Host) modular jack interface —This
jack is provided for connection to your own telephone set, or
business telephone system (PBX or EKTS) (the host system).
Central Office RJ11 (J2) modular jack interface —This jack is
provided for connection to a C.O. telephone line (from
telephone company’s central office).
WARNING: RISK OF ELECTRICAL SHOCK —
EQUIPMENT MUST BE PROPERLY GROUNDED.
Your AT&T equipment requires a properly grounded
three-prong power receptacle for safe operation. Have
the receptacle checked by a qualified electrician before
connecting this equipment. Do not cut or remove the
third (ground) prong from the power transformer. Do
not use two-prong extension cords or adapters to
defeat the safety features of this equipment. If you
have a two-prong receptacle, it must be replaced with
a three-prong receptacle, installed by a qualified
electrician.
Installation Procedures
2-7
AT&T DOOR PHONE
CONTROLLER
BACK PANEL
RJ11
14-POSITION
CONNECTORS
TERMINAL STRIP
(REMOVABLE)
Figure 2-1. Door Phone Controller Back Panel Connections
Prior To Installation
NOTE: Consider the following items before installation:
1. Never install telephone wiring during a lightning storm.
telephone jacks in wet locations unless the
2. Never install
jack is specifically designed for wet locations.
3. Never touch uninsulated telephone wires or terminals un-
line has been disconnected at the
less the telephone
network interface.
4.
installing or modifying
telephone lines.
Use caution when
2-8
Installation Procedures
AT&T Door Phone Controller Location
You need to determine exactly where you want the unit
installed and how you want it configured. Another consideration
is what components will be used with the AT&T Door Phone
Controller. Here are some questions that must be answered
prior to installation:
■ Do you currently have a door speaker installed?
■ Do you have a business telephone system (PBX or EKTS)?
■ Do you have a remote door unlock mechanism (electric
door strike) installed?
■ Do you have an auxiliary alert system (door chime) currently
installed?
■ Do you have a door ajar switch installed?
The AT&T Door Phone Controller is designed to control the
functions of the components mentioned above, and how you
answer these questions will determine how the AT&T Door
Phone Controller will be installed, optioned, and operated.
When selecting options for your AT&T Door Phone Controller,
e.g., to change the door-unlock security code, the AT&T Door
Phone Controller unit must be DIP switch selected to Option
Selection mode. For this reason you may want to install the
AT&T Door Phone Controller unit in a secure area which has
access only by authorized personnel. If you are installing the
unit in a business environment (currently have PBX/EKTS), you
may wish to install the unit along with the telephone equipment.
Installation Procedures
2-9
22-24 GAUGE
WIRE
AUX. ALERT DEVICE
TELEPHONE
EXTENSION
AT&T DOOR PHONE
CONTROLLER
22-24 GAUGE
WIRE
(Secure Location)
DOOR AJAR
SWITCH
EXISTING
PHONE
LINES
DOOR SPEAKER
W/ PUSH BUTTON
MODULAR
PHONE
CABLE
SHIELDED TWISTED
PAIR SPEAKER
WIRES
ATTENDENT
POSITION
TELEPHONE
EQUIP.
ELECTRIC
DOOR STRIKE
PLATE DEVICE
22-24 GAUGE
WIRE
Figure 2-2. Typical AT&T Door Phone Controller Installation
2-10
Installation Procedures
Installation
Mounting Instructions
The AT&T Door Phone Controller can be placed on a flat table
or shelf, or mounted to a wall.
Wall Mount Instructions
The AT&T Door Phone Controller is shipped with a keyhole
mounting template and mounting screws. Follow the steps
below to mount the Door Phone Controller to a wall.
When moving AT&T Door
Phone Controller or adding/
removing cables from back
panel, unplug transformer from
120V outlet.
1. Place template (tear-out page at end of manual) over
desired wall mounting location and mark screw positions.
2. Use a Philips screwdriver to screw each of the two
screws into the marked screw positions.
IMPORTANT: Do not drive screws all the way into
wall; adequate space (5/16'') must be left to position
the AT&T Door Phone Controller bottom panel
keyholes over screw heads.
Also unplug the terminal strip
and modular phone connectors
on the back panel.
3. Mount the AT&T Door Phone Controller over the protrud-
ing screw heads and seat unit firmly to the wall. See
WARNING: RISK OF ELECTRICAL SHOCK —
EQUIPMENT MUST BE PROPERLY GROUNDED.
Your AT&T equipment requires a properly grounded
three-prong power receptacle for safe operation. Have
the receptacle checked by a qualified electrician before
connecting this equipment. Do not cut or remove the
third (ground) prong from the power transformer. Do
not use two-prong extension cords or adapters to
defeat the safety features of this equipment. If you
have a two-prong receptacle, it must be replaced with
a three-prong receptacle, installed by a qualified
electrician.
Installation Procedures
2-11
4. When the AT&T Door Phone Controller is securely
mounted to the wall, then all cables and wires can be
connected to the terminal strip and then plugged into
the back panel.
DOOR PHONE
CONTROLLER
BACK PANEL
KEYHOLE
MOUNTING
SLOTS
5/16'' TYPICAL
8.1''
MOUNTING SCREWS
Figure 2-3. Mounting AT&T Door Phone Controller to
Wall
2-12
Installation Procedures
Connecting Door Speaker, Door Button, and Door
Ajar Switch to the AT&T Door Phone Controller
Polarity of wires is not important.
1.
Run shielded twisted pair wires (22–24AWG) from the
“Speaker” terminals on the rear panel of the AT&T Door
Phone Controller (13 & 14) to the installed Door
Speaker (1 & 2). Connect the shield to the “Shield” ter-
minal on the controller (12).
Total wire length should not
exceed 1500 feet.
Door Ajar switch should be
closed when door is closed. If a
door ajar switch will not be
used, you must leave a jumper
installed across the two “Door
Ajar Switch” terminals.
2. Run 2 wires (22–24AWG) from the “Door Bell Button”
terminals (10 & 11) to the door bell push button on the
installed door speaker/push button assembly (3 & 4).
3. Run 2 wires (22-24AWG) from the optional “Door Ajar
Switch” terminals (8 & 9) to the installed door ajar
switch.
Remote Door Open Switch (optional)
A remote door open switch (normally-open contact) provides
additional means for opening an electric door opening device.
To connect wires for a remote door open switch use the
1. Install the remote door open button in desired location
using manufacturer’s installation instructions.
2. Run 2 wires (22–24AWG) from the installed (normally-
open contact) remote door open switch to the “Remote
Door Open” terminals (6 & 7) on the AT&T Door Phone
Controller back panel (polarity of wires is not important).
Installation Procedures
2-13
AT&T DOOR PHONE CONTROLLER
BACK PANEL
AT&T DOOR SPEAKER
AND DOOR BELL
BUTTON
SHIELDED, TWISTED PAIR, 24 AWG.
APPROX. 1500 FT. MAXIMUM LENGTH
JUMPER THE TWO DOOR AJAR SWITCH TERMINALS
IF DOOR AJAR DEVICE IS NOT USED
DOOR AJAR SWITCH
NOTE: MAGNETIC SWITCH
IS CLOSED WHEN DOOR
IS CLOSED
Figure 2-4. Connections for AT&T Door Phone Speaker, Door Button and Door
Ajar Devices
2-14
Installation Procedures
AT&T DOOR PHONE
CONTROLLER BACK PANEL
MOMENTARY
PUSH BUTTON
NORMALLY OPEN
Figure 2-5. Connections for Remote Door Open Switch (optional)
Electric Door Strike Plate Device (optional)
An electric door strike plate is used to automatically open a
closed or locked door. A low-voltage device (24V or less) is
recommended. The AT&T Door Phone Controller can provide
an open or closed contact when requested to interface to and
to operate your electric door strike plate device. Once an
electric door strike plate has been installed, it can be controlled
by the AT&T Door Phone Controller unit, either from entering
the appropriate digits from a touch tone phone or from the
Remote Open switch (push button).
If your Electric Door Strike Plate
has more than a 1 Amp current
draw, then an external relay
arrangement is required.
door strike plate device to the AT&T Door Phone Controller.
Installation Procedures
2-15
1. Have the electric door strike pIate device installed as in-
structed by the manufacturers installation manual.
Check electric installation codes and local ordinances
for exact wiring requirements in your area.
2. Normally Open (N.O.), Normally Closed (N.C.), and
Common (C.) relay contacts are accessible at the Door
Phone Controller terminal block. Wire these to the door
strike plate device and its power source as instructed by
your manufacturer’s installation manual. If no instruc-
tions exist, wire the above relay contacts to the existing
door open button (see #3 below).
Do not include strike plate wires
within the same cable as others
wires connecting to the AT&T
Door Phone Controller.
AT&T DOOR PHONE
CONTROLLER BACK PANEL
ELECTRIC
DOOR STRIKE
PLATE DEVICE
WITH POWER
SOURCE
Figure 2-6. Connections for Electric Door Strike Plate (optional)
2-16
Installation Procedures
3. Verify all connections when connecting the door strike
contacts on the AT&T Door Phone Controller to existing
door open buttons. Make sure of the following:
■
The NO and C contacts are connected in parallel to a
normally-open button.
NOTE: One or the other will
apply, not both.
■
The NC and C contacts are connected in series to a
normally-closed button.
(optional)
Auxiliary Alert Device
In most configurations, the Door Phone Controller will cause a
telephone to ring when the doorbell button is pushed. An aux-
iliary alert device (chime, bell, horn, tone generator, etc.) can
also be used as an alert to notify the person inside the building
that the doorbell button has been pushed (Auxiliary Alert
Mode). A low-voltage device (24V or less) is recommended.
alert device (door bell/chime) to the Door Phone Controller:
If the Auxiliary Alert Device has
more than a 1 Amp draw, then
an external relay arrangement
will be required.
Install the auxiliary alert device (door bell/chime) as in-
structed by the manufacturer’s installation manual.
1.
2. The Normally Open (N.O.) and Common (C.) relay con-
tact, located on the Door Phone Controller back panel
troller terminal block. Wire these to the auxiliary alert
device and it’s power source as instructed by the
manufacturer’s installation manual.
auxiliary alert device installation
information.
Connecting Power
When the Door Phone Controller has been mounted to a wall
or placed on a shelf and all cables and wires have been
connected to the back panel, plug the transformer into a 120
Installation Procedures
2-17
Operation and Controls Information
Door Ajar Function
Default Condition —After the door has been opened by the
four digit code or the remote push button, the Door Phone
Controller will wait for the Door Ajar Call-back time-out to
elapse. At this point if the door is still open, the Door Phone
Controller will call back the phone/chime for the duration of the
ring/chime duration and then repeat after the Door Ajar
Call-back time-out has elapsed again. If the phone is answered
during that time, a Door Ajar Tone will be heard. The Door Ajar
Tone will cease when any DTMF Digit is pressed, or the user
speaks or hangs-up.
Alternate Condition —If the door is ever opened and the Door
Ajar Call-back time-out has elapsed, the Door Phone Controller
will call back the phone/chime for the duration of the ring/chime
duration and then repeat after the Door Ajar Call-back time-out
has elapsed again. If the phone is answered during that time, a
Door Ajar Tone will be heard. The Door Ajar Tone will cease
when any DTMF digit is pressed, or the user speaks or
hangs-up.
Speaker Volume Control
You can adjust the volume level of the door speaker by
adjusting the Speaker Volume Control on the Door Phone
Talk Back Volume Control
You can adjust the volume level from the door speaker to an
inside telephone extension by adjusting the Talk Back Volume
2-20
Installation Procedures
LED
When the AT&T Door Phone Controller is powered on and
blink 2.5 times a second. If there is a malfunction the LED will
section) or go out completely. If the LED is not lit, check power
to unit first before calling for repair.
Installation Procedures
2-21
Connecting the AT&T Door Phone Controller to
Your Telephone Equipment
AT&T Door Phone Controller to your residential or
business-type telephone equipment. Answer each appropriate
question in the flow chart and refer to the section specified
within this manual. Then proceed with the necessary
installation and option selection requirements. NOTE: If you
are installing the AT&T Door Phone Controller into a
typical Home/Residential environment (no PBX) refer to
REFER TO
RESIDENTIAL INSTALLATION
NO
Do
you have a
Business
REFER TO
Telephone
PBX WITH DEDICATED
System
?
YES
Spare
TRUNK PORT
YES
Trunk Port
Available*
?
REFER TO
YES
Spare
PBX WITH STATION PORT
NO
Station Port
Available*
?
REFER TO
NO
*You must refer to your telephone system
owner manual for description of this
port.
PBX WITHOUT DEDICATED
TRUNK OR STATION PORT
Figure 2-9. Configuration of Telephone Equipment Flow Chart
2-22
Installation Procedures
Overview
This section provides installation and operation information for
applications such as residences or small businesses which do
not have a telephone system.
When your AT&T Door Phone Controller is installed with
standard telephone equipment (no PBX), the unit may operate
in Shared Line Mode which permits a single telephone set to
be shared between the AT&T Door Phone Controller and an
outside line (to a Central Office). Thus, the standard telephone
equipment can be used for normal call operations as well as
servicing the door.
You may also use the AT&T
Door Phone Controller with a
dedicated phone.
DIP Switch Selections
To customize the AT&T Door Phone Controller to your specific
installation and option requirements, you must properly set the
8 position DIP switch located on the AT&T Door Phone
CAUTION: Do not connect to the modular jacks on
the AT&T Door Phone Controller until after the DIP
switches have been properly set.
When using the Door Phone Controller with a small business or
residential telephone equipment (no PBX installed), the DIP
Complete information about the
DIP switch settings can be
Home/Residential
Installation —
3-2
LEGEND
1
2
3
4
5
6
7
8
ON
Off
On
I
—
NOTE: The Forced Disconnect
Timeout option does not apply
when DIP switch position 8 is ON.
ON for
Option Selection
Mode Only
I
—
Figure 3-1
.
Home/Residential DIP Switch Settings
Installation
Connect the Door Phone Controller using the information in
When moving the Door Phone
Controller or adding or removing
cables from the back panel,
unplug the transformer from
120V outlet. Also unplug the
terminal strip and modular
phone connectors on the back
panel.
Installation — Home/Residential
3-3
AT&T DOOR PHONE CONTROLLER
BACK PANEL
TO DOOR SPEAKER
TO DOORBELL BUTTON
TO DOOR AJAR SWITCH
TO REMOTE DOOR OPEN SWITCH
OPTIONAL
TO DOOR STRIKE PLATE DEVICE
TO C.O.
TO AUXILIARY ALERT DEVICE (DOOR BELL/CHIME)
(Outside Line)
TO TELEPHONES
Figure 3-2. Connecting AT&T Door Phone Controller to Standard Telephone
Equipment
3-4
Installation — Home/Residential
Option Selection
The final step of the installation procedure is selecting options
for your AT&T Door Phone Controller. The selection of these
options must be done while in the Option Selection Mode. This
mode lets you control such things as:
detailed explanation of each of
these options.
■
■
■
■
■
■
■
■
■
Delay Before Door Ajar Call-Back
Ring/Chime Cadence
Ring/Chime Duration
Door Unlock Code
Door Unlock Duration
Enable Door Code
Door Ajar Mode
Forced Disconnect
Time-Out
Reset Options to Factory Defaults
Follow the steps below to select options for the Door Phone
Controller.
1.
Select Option Selection Mode by setting position 8
of the Door Phone Controller DIP switch to the ON
2. Once the DIP switch has been set, you must make con-
nection to the door speaker by “hook-flashing” the
phone (within 5 seconds) and entering “##3” on the
telephone keypad (option selection mode is active as
soon as you hear a distinctive dial tone).
Any or all options may be
reselected in any order.
Installation — Home/Residential
3-5
Table 3-1. AT&T Door Phone Controller Option Selection Information
Mode Option/
Verify
Listen
Listen
For
Options
Press
Press
Default
To Select Option
To Verify
00
01
Delay Before
Door Ajar
Call-back
Single 000 to 255 for 0 to 255
Double
Beep
30 sec.
Beep
seconds of delay after strike
plate release stops until
AT&T Door Phone Controller
calls back to indicate that
door is ajar
To Select Option
To Verify
10
Ring/Chime
Cadence
Single 24 (for 2 sec. on 4 sec. off
o r
Double
Beep
2 sec./
4 sec.
Beep
cadence)
11
15 (for 1 sec. on 5 sec. off
cadence)
Ring/Chime
Duration
To Select Option
To Verify
20
21
Single 00 to 99 (0 to 99 second(s)
ring/chime)
Double
Beep
30 sec.
Beep
To Select Option
To Verify
30
31
Door Unlock
Code
Single 4 digits (first digit must be
Double
Beep
6736
“OPEN”
Beep
0,3,4,5,6,7 or 8
remaining digits can be set
from 0 to 9)
To Select Option
To Verify
40
41
Door Unlock
Duration
Single 00 to 99 (door lock active
Double
Beep
4 sec.
Beep
time in sec.)
To Select Option
To Verify
50
51
Enable Door
Code
Single
Beep
1
0
Enable door code
Disable door code
Double
Beep
1
(Enabled)
Door Ajar
Mode
To Select Option
To Verify
50
51
Single
Beep
2
3
For callback after strike
plate release only
For callback anytime
door is opened
Double
Beep
2
To Select Option
To Verify
60
61
Forced
Disconnect
Time-Out
Single 010 to 255 (unit disconnects
in 10 to 255 sec.)
Double
Beep
120 sec.
N/A
Beep
To Select Option
To Verify
70
71
Reset Options
to Factory
Defaults
Single ## (to restore factory default
Beep
Double
Beep
conditions)
NOTE: The Door Ajar Delay (Option Selection) will begin when the call to the door speaker is disconnected.
.
Home/Residential
Installation —
3-6
The Forced Disconnect
4. To exit option selection mode, press “##3” on the
telephone keypad (you will hear 2 beeps). Hang up the
phone.
Time-out option does not apply
when setting options (unless 2
minutes elapse without a
Touch-Tone selection)
Phone Controller DIP
5. Set position 8 of the AT&T Door
switch back to the OFF position.
Basic Door Answer Function
Operation –
Visitor Presses Door Speaker Button
When a visitor presses the door speaker push button, the
AT&T Door Phone Controller will signal the telephone
equipment inside your home or building to ring, and activate a
door-bell/chime device (optional). Any additional presses on the
door speaker push button will be ignored until the option
selected ring/chime duration has expired (with the exception
that a confirmation tone will still be sent to the speaker when
the door button is pressed).
Answering a Call from the Door Speaker
The person inside the building can simply answer the ringing
phone and establish two-way communications with the door
speaker. To open the door, the person inside the building either
enters the Door Code on the telephone’s keypad or presses
the customer provided door-unlock push button. Either of these
actions will activate the customer provided electric door strike
plate device.
Home/Residential
3-7
Installation —
As an alternative response when the telephone or door
bell/chime is heard, the person inside the building can press
the door-unlock push button, which will stop the ringing and will
open the door. This allows the door to be unlatched without the
use of a phone.
Calling the Door Speaker from Inside the Building
To initiate a call to the door, the person within the building
simply takes the telephone off-hook and hook-flashes the
telephone within the first 4 seconds. At this point, there will be
direct two-way communication from within the building to the
door speaker.
Telephone Line In Use When Visitor Presses Door
Speaker Button
If a visitor presses the door speaker button while an existing
call is already taking place on the C.O. line, the AT&T Door
Phone Controller will generate a “door alert” signal to indicate
Once the push button is
a visitor needs attention at the entrance. The person inside the
building can hook-flash the phone and be in direct two-way
communication to the door speaker. Then normal AT&T Door
Phone Controller functions can take place. When door phone
functions have been completed, i.e., door has been remotely
opened, hook-flashing the phone again within the forced
disconnect timeout (or pressing 9) will return the line back to
the original call. This feature operates much like a call-waiting
function.
pressed, you can “Hook Flash”
to the door speaker and then
back to the original call only
once, unless the push button is
pressed again.
If you forget to hook-flash back
to the original call, the AT&T
Door Phone Controller will call
you back.
3-8
Installation — Home/Residential
Telephone Line In Use With Door When Incoming Call
Arrives
If there is a call in progress between the door speaker and a
person inside the building and a C.O. call comes in, the person
inside the building (not the door speaker) will hear a call
waiting tone. The person inside the building can hook-flash the
phone (or dial 9) and communicate with the incoming caller.
When the call is complete, the person inside the building hangs
up the phone or to speak with the person at the door speaker
again, the person inside the building must hook-flash the phone
(within 4 seconds after picking up the receiver).
Home/Residential
3-9
Installation —
Overview
This section provides installation and operation information for
installations with a telephone system that has an available
Dedicated Trunk port.
DIP Switch Selections
Complete information about the
DIP switch settings can be
To customize the AT&T Door Phone Controller to your specific
installation and option requirements, you must properly set the
8-position DIP switch located on the AT&T Door Phone
CAUTION: Do not connect to the modular jacks on the
AT&T Door Phone Controller until after the DIP switches
have been properly set.
When using the AT&T Door Phone Controller with a telephone
system which has an available dedicated trunk, set the DIP
switch.
Prior to setting this DIP switch,
you must know if the dedicated trunk is Loop Start or Ground
Start; this information can be obtained from your local
telephone company.
4-2
Installation - Dedicated Trunk Port
1
2
3
4
5
6
7
8
LEGEND
ON
LOOP START
. . . The C.O.
(Trunk Saver Mode)
Off
On
Immediately
ON for
Option Selection
Mode Only
after cut-thru
(Dialing Trunk) to AT&T
Door Phone Controller,
what do you want to
be connected
to...?
.
. . The DOOR
(Port Saver Mode)
1
2
3
4
5
6
7
8
ON
LOOP START
Figure 4-1. DIP Switch Setting for PBX with Dedicated Trunk Port
Installation
When moving the AT&T Door
To customize the AT&T Door Phone Controller use the
phone connectors on the back panel.
Phone Controller or adding or
removing cables from the back
panel, unplug transformer from
120V outlet. Also unplug the
terminal strip and modular
cords.
Install the AT&T Door Phone Controller using the information
Complete information regarding
each DIP switch position can be
Installation - Dedicated Trunk Port 4-3
AT&T DOOR PHONE
CONTROLLER BACK PANEL
TERMINAL BLOCK “HARD
WIRE” CONNECTOR
NOT USED
TO DOOR SPEAKER
TO DOOR BELL BUTTON
TO DOOR AJAR SWITCH
TO REMOTE DOOR OPEN SWITCH
OPTIONAL
TO DOOR STRIKE PLATE DEVICE
TO AUXILIARY ALERT DEVICE (DOOR BELL/CHIME)
TELEPHONE SYSTEM
STATION
PORT
TRUNK PORT
TO C.O.
TO C.O.
TRUNK PORT
TRUNK PORT
NOTE: For Ground Start installations
STATION
PORT
Figure 4-2a. Connecting Door Phone Controller to Standard Telephone Equipment
4-4
Installation - Dedicated Trunk Port
TO AT&T DOOR PHONE CONTROLLER
J1 CONNECTORS
TO “SHIELD” TERMINAL (12) ON AT&T
NE CONTROLLER
DOOR PHO
TELEPHONE SYSTEM
GROUND TERMINAL
TRUNK PORT STATION
PORT
TRUNK PORT
TO C.O.
STATION
PORT
TRUNK PORT
NOTE: For Ground Start installations:
TELEPHONE SYSTEM
Connect the green wire to Tip
and the red wire to Ring.
Figure 4-2b. Ground Start Installations
Installation - Dedicated Trunk Port 4-5
Option Selection
The final step of the installation procedure is selecting options
for your AT&T Door Phone Controller. The selection of these
options must be done while in the Option Selection Mode. This
mode lets you control such things as:
detailed explanation of each of
these options.
■
■
■
■
■
■
■
■
■
Delay Before Door Ajar Call-Back
Ring/Chime Cadence
Ring/Chime Duration
Door Unlock Code
Door Unlock Duration
Enable Door Code
Door Ajar Mode
Forced Disconnect Time-Out
Reset Options to Factory Defaults
4-6
Installation - Dedicated Trunk Port
Follow the steps below to select options for your AT&T Door
Phone Controller.
CAUTION: Never connect an AT&T DOOR PHONE
CONTROLLER with the DIP Switches optioned for TRUNK
access to a STATION LINE! Doing so may cause damage
to the STATION LINE and/or the AT&T DOOR PHONE
CONTROLLER!
1. Select Option Selection Mode by setting position 8
of the AT&T Door Phone Controller DIP switch to
2. Once the DIP switch has been set, you must make con-
nection to the door speaker by accessing the trunk
connected to the AT&T Door Phone Controller. At this
point you must enter “##3” on the telephone keypad (op-
tion selection mode is active as soon as you hear a
distinctive dial tone).
Any or all options may be
reselected in any order,
The Forced Disconnect
4. To exit option selection mode, press “##3” on the
telephone keypad, you will hear 2 beeps. Hang up the
phone.
Time-out option does not apply
when setting options (unless 2
minutes elapse without a
Touch-Tone selection).
5. Set position 8 of the AT&T
Door Phone Controller DIP
the OFF position.
Installation - Dedicated Trunk Port 4-7
Operation –
Basic Door Answer Function
Table 4-1. AT&T Door Phone Controller Option Selection Information
Mode Option/
Verify
Listen
For
Listen
For
Options
Press
Press
Default
Delay Before
Door Ajar
Call-back
To Select Option
To Verify
00
01
Single 000 to 255 for 0 to 255
Double
Beep
30 sec.
Beep
seconds of delay after strike
plate release stops until
AT&T Door Phone Controller
calls back to indicate that
door is ajar
Ring/Chime
Cadence
To Select Option
To Verify
10
11
Single 24 (for 2 sec. on 4 sec. off
or
Double
Beep
2 sec./
4 sec.
Beep
cadence)
15 (for 1 sec. on 5 sec. off
cadence)
Ring/Chime
Duration
To Select Option
To Verify
20
21
Single 00 to 99 (0 to 99 second(s)
Beep
Double
Beep
30 sec.
ring/chime)
Door Unlock
Code
To Select Option
To Verify
30
31
Single 4 digits (first digit must be
Double
Beep
6736
“OPEN”
Beep
0,3,4,5,6,7 or 8
remaining digits can be set
from 0 to 9)
Door Unlock
Duration
To Select Option
To Verify
40
41
Single
Beep
00 to 99 (door lock active
time in sec.)
4 sec.
Double
Beep
Enable Door
Code
To Select Option
To Verify
50
51
Single
Beep
1
0
Enable door code
Disable door code
Double
Beep
1
(Enabled)
Door Ajar
Mode
To Select Option
To Verify
50
51
Single
Beep
2
3
For callback after strike
plate release only
For callback anytime
door is opened
Double
Beep
2
Forced
Disconnect
Time-Out
To Select Option
To Verify
60
61
Single
010 to 255 (unit disconnects
Double 120 sec.
Beep
Beep in 10 to 255 sec.)
Reset Options
to Factory
Defaults
To Select Option
To Verify
70
71
Single ## (to restore factory default
Double
Beep
N/A
Beep
conditions)
NOTE: The Door Ajar Delay (Option Selection) will begin when the call to the door speaker is disconnected.
4-8
Installation - Dedicated Trunk Port
Visitor Presses Door Speaker Button
When a visitor presses the door speaker push button, the
AT&T Door Phone Controller will signal the telephone
equipment inside your building to ring and activate a
door-bell/chime (optional). Any additional presses on the door
speaker push button will be ignored (with the exception that a
confirmation tone will still be sent to the speaker when the door
button is pressed).
Answering a Call From the Door Speaker
When a person inside the building hears the telephone ring
and/or the door bell/chime sound, he can simply respond by
answering the ringing phone. At this point, the AT&T Door
Phone Controller will establish two-way communication with the
door speaker. To open the door, the person inside the building
either enters the Door Code on the telephone’s keypad or
presses the door-unlock push button. Either of these actions
will activate the customer provided electric door strike plate
device.
As an alternative response to hearing the telephone or door
bell/chime, the person inside the building can press the
door-unlock push button which will stop the ringing and will
open the door. This allows the door to be unlatched without the
use of a phone.
Calling the Door Speaker
To initiate a call to the Door Speaker, the person inside the
building simply takes the telephone off-hook and accesses the
trunk connected to the AT&T Door Phone Controller.
Installation - Dedicated Trunk Port 4-9
Overview
This section provides installation and operation information for
installations which use on-premise telephone system that has
an available Dedicated Analog Station Port.
DIP Switch Selections
To customize the AT&T Door Phone Controller to your specific
Complete information about the
DIP switch settings can be
installation and option requirements, you must properly set the
8-position DIP switch located on the AT&T Door Phone
CAUTION: Do NOT connect to the modular jacks on
the AT&T Door Phone Controller until after the DIP
switches have been properly set.
When using the AT&T Door Phone Controller with a telephone
system which has an available dedicated station port, set the
switch, you must know if the telephone system is configured for
explanation of ringdown and auxiliary modes).
to properly set the DIP switch.
5-2
Installation - Dedicated Station Port
AUX. ALERT
MODE
LEGEND
1
2
3
4
5
6
7
8
ON
O n
Off
N O
Will you
ON for
configure your
telephone system
for Ringdown
?
Option Selection
Mode Only
YES
1
2
3
4
5
6
7
8
ON
R I N G D O W N
M O D E
Figure 5-1 DIP Switch Configuration for Telephone System with Dedicated
.
Station Access, Station Mode
Installation
To customize the AT&T Door Phone Controller for this type of
installation, you must properly configure the 8-position DIP
switch located on the Door Phone Controller front panel (see
the DIP switch.
When moving the AT&T Door
Phone Controller or adding or
removing cables from the back
panel, unplug transformer from
120V outlet. Also unplug the
terminal strip and modular
phone connectors on the back
panel.
Installation - Dedicated Station Port
5-3
Install the AT&T Door Phone Controller using the information in
AT&T DOOR PHONE
CONTROLLER BACK PANEL
TERMINAL BLOCK “HARD
WIRE” CONNECTOR
NOT USED
TO DOOR SPEAKER
TO DOOR BELL BUTTON
TO DOOR AJAR SWITCH
TO REMOTE DOOR OPEN SWITCH
OPTIONAL
TO DOOR STRIKE PLATE DEVICE
TO AUXILIARY ALERT DEVICE (DOOR BELL/CHIME)
TELEPHONE SYSTEM
ANALOG
STATION PORT
TO C.O.
TRUNK PORT STATION
P O R T
Figure 5-2. Connecting the AT&T Door Phone Controller to a Telephone System
with Dedicated Analog Station Port
5-4
Installation - Dedicated Station Port
Option Selection
The final step of the installation procedure is selecting options
for your AT&T Door Phone Controller. The selection of these
options must be done while in the Option Selection Mode. This
mode lets you control such things as:
detailed explanation of each of
these options.
■ Delay before Door Ajar Call-Back
■
■
■
■
■
■
■
■
■
■
Ring/Chime Cadence
Ring/Chime Duration
Door Unlock Code
Door Unlock Duration
Enable Door Code
Door Ajar Mode
Forced Disconnect Time-Out
Reset Options to Factory Defaults
Phone Number Storage Memory 1
Phone Number Storage Memory 2
Installation - Dedicated Station Port
5-5
Follow the steps below to select options for the AT&T Door
Phone Controller.
CAUTION: Never connect an AT&T DOOR PHONE
CONTROLLER with the DIP Switches optioned for TRUNK
access to a STATION LINE! Doing so may cause damage
to the STATION LINE and/or the AT&T DOOR PHONE
CONTROLLER!
Select Option Selection Mode by setting position 8
of the AT&T Door Phone Controller DIP switch (see
1.
2. Once the DIP switch has been set, you must make con-
nection to the door speaker by calling the extension
number assigned to the Door Phone Station Port. At
this point you must enter “##3” on the telephone
keypad (option selection mode is active as soon as you
hear a dial tone).
Any or all options may be
reselected in any order.
The Forced Disconnect
4. To exit option selection mode, press “##3” on the
telephone keypad. You will hear 2 beeps. Hang up the
phone.
Time-out option does not apply
when setting options (unless 2
minutes elapse without a
Touch-Tone selection).
5. Set position 8 of the AT&T Door Phone Controller DIP
switch back to the OFF position.
5-6
Installation - Dedicated Station Port
Table 5-1. AT&T Door Phone Controller Option Selection Information
Mode Option/
Verify
Listen
Press For
Listen
For
Default
Options
Press
To Select Option
To Verify
00
01
Single 000 to 255 for 0 to 255 seconds
Double
Beep
30 sec.
Delay Before Door
Ajar Call-back
Beep
of delay after strike plate
release stops until AT&T Door
Phone Controller calls back to
indicate that door is ajar
To Select Option
To Verify
10
Single 24 (for 2 sec. on 4 sec. off
or
Double
Beep
2 sec./
4 sec.
Ring/Chime
Cadence
cadence)
Beep
15 (for 1 sec. on 5 sec. off
cadence)
11
To Select Option
To Verify
20
21
30
31
Single 00 to 99 (0 to 99 second(s)
ring/chime)
Double
Beep
30 sec.
Ring/Chime
Duration
Beep
To Select Option
To Verify
Single 4 digits (first digit must be
Double
Beep
6736
“OPEN”
Door Unlock Code
0,3,4,5,6,7 or 8;
Beep
remaining digits can be set from
0 to 9)
To Select Option
To Verify
40
41
50
51
50
51
Single 00 to 99 (door lock active time
in sec.)
Double
Beep
4 sec.
Door Unlock
Duration
Beep
To Select Option
To Verify
Single 1 Enable door code
Double
Beep
1
Enable Door Code
Door Ajar Mode
Beep
0 Disable door code
(Enabled)
To Select Option
To Verify
Single
Beep
2
3
For callback after strike
plate release only
For callback anytime
door is opened
Double
Beep
2
To Select Option
To Verify
60
6 1
7 0
71
80
Single 10 to 255 (unit disconnects in
10 to 255 sec.)
Double
Beep
120 sec.
Forced Disconnect
Time-Out
Beep
To Select Option
To Verify
Single ## (to restore factory default
Beep conditions)
Double
Beep
N/A
#
Reset Options to
Factory Defaults
To Select Option
To Verify
Single 0 to 20 numerical digits and
Double
Beep
Phone Number
Storage Memory 1
❊ ( ❊ = 2 second pause) #
terminates entry
Beep
81
90
91
To Select Option
To Verify
Single 0 to 20 numerical digits and
Double
Beep
#
Phone Number
Storage Memory 2
❊ ( ❊ = 2 second pause) #
terminates entry
Beep
Installation - Dedicated Station Port
5-7
Operation
– Basic Door Answer Function
Auxiliary Alert Mode
When a visitor presses the door speaker push button, the Door
Phone Controller will activate an auxiliary alert
Visitor Presses Door
Speaker Button
(door-bell/chime). Any additional presses on the door speaker
push button will be ignored (with the exception that a
the door
confirmation tone will still be sent to the speaker when
button is pressed).
When a person inside the building hears the door bell/chime
sound, he can simply respond by dialing the Door Phone
Controller station number. At this point, the AT&T Door Phone
Controller will establish two-way communications with the door
speaker.
Answering a Call Sent
From the Door Phone
To open the door, the person inside the building either enters
The telephone system must
pass Touch Tones to the station
port connected to the AT&T
Door Phone Controller in order
for the Door Code to be
recognized.
the Door Code on the telephone’s keypad or presses the
,
customer provided door-unlock push button. Either of these
actions will activate the customer provided electric door
release.
As an alternative response to hearing the door bell/chime, the
person inside the building can press the door-unlock push
button which will stop the auxiliary contacts and will open the
door. This allows the door to be unlatched without the use of a
phone.
Complete installation
instructions for adding an
Auxiliary Alert option can be
To initiate a call to the Door Speaker, the person inside the
building simply takes the telephone off-hook and dials the
station phone number of the door speaker.
Calling the Door
Speaker
Ringdown Mode – Basic Door Answer Function
When a visitor presses the door speaker push button, the
AT&T Door Phone Controller will activate a door-bell/chime
(optional), go off-hook, and dial the pre-selected stored phone
Visitor Presses Door
Speaker Button
5-8
Installation - Dedicated Station Port
number, 1 or 2 (these can be selected by pressing ##1 or ##2
once connection to the speaker has been made). Any
additional presses on the door speaker push button will be
ignored while the Door Phone Controller is off-hook.
When a person answers the ringing telephone, the Door Phone
Controller will establish two-way communications with the door
speaker.
Answering a Call Sent
From the Door Phone
To open the door, the person inside the building either enters
the Door Code on the telephone’s keypad or presses the
customer provided door-unlock push button.
Opening door will terminate
station mode access.
Either of these actions will close the metallic contacts which
activate the customer provided electric door release.
To initiate a call to the Door Speaker, the person inside the
building simply takes the telephone off-hook and dials the
station phone number of the door speaker.
Calling the Door
Speaker
Installation - Dedicated Station Port
5-9
Overview
This section provides installation and operation information for
installations which use a telephone system that does not have
an available Dedicated Trunk or Station Port. By configuring
the telephone system to the instructions in this section, your
telephone system equipment will operate in Trunk/Port share
mode.
Ground start trunks will NOT
operate properly with this
shared trunk installation.
DIP Switch Selections
To customize the AT&T Door Phone Controller to your specific
Complete information about the
DIP switch settings can be
installation and option requirements, you must properly set the
8-position DIP switch located on the AT&T Door Phone
Saver or Port Saver Mode.
A trunk shared with the AT&T Door Phone should never be
configured in a telephone system with other trunks in a
common pool or group.
6-2
Installation - No Dedicated Trunk/Station Port
1
2
3
4
5
6
7
8
LEGEND
LOOP START
ON
.
. . The C.O.
(Trunk Saver Mode)
O f f
O n
Immediately
after cut-thru
ON for
Option Selection
Mode Only
(Dialing Trunk) to AT&T
Door Phone Controller,
what do you want to
be connected
to...?
.
. . The DOOR
(Port Saver Mode)
1
2
3
4
5
6
7
8
ON
LOOP START
Figure 6-1. DIP Switch Setting for PBX With Shared Trunk Port
Installation
When moving the AT& T Door
Phone Controller or adding or
removing cables from the back
panel, unplug transformer from
120V outlet, Also unplug the
terminal strip and modular
phone connectors on the back
panel.
Install the AT&T Door Phone Controller using the information in
To customize the AT&T Door Phone Controller for this type of
installation, you must properly set the 8-position DIP switch
located on the AT&T Door Phone Controller front panel (see
the DIP switch.
Complete information regarding
each of the DIP switch positions
CAUTION: Do NOT connect to the modular jacks on
the AT&T Door Phone Controller until after the DIP
have been properly set.
switches
Installation - No Dedicated Trunk/Station Port
6-3
AT&T DOOR PHONE
CONTROLLER BACK PANEL
TERMINAL BLOCK "HARD
WIRE" CONNECTOR
TO DOOR SPEAKER
TO DOOR BELL BUTTON
TO DOOR AJAR SWITCH
TO REMOTE DOOR OPEN SWITCH
OPTIONAL
TO DOOR STRIKE PLATE DEVICE
TO AUXILIARY ALERT DEVICE (DOOR BELL/CHIME)
TELEPHONE SYSTEM
TO C.O.
(TELEPHONE LINE)
TRUNK PORT
(LOOP START)
STATION
P O R T
TO C.O.
TRUNK PORT
STATION
PORT
Figure 6-2. Connecting the AT&T Door Phone Controller to a Telephone System
With Shared Trunk Port
6-4
Installation - No Dedicated Trunk/Station Port
Option Selection
The final step of the installation procedure is selecting options
for your AT&T Door Phone Controller. The selection of these
options must be done while in the Option Selection Mode. This
mode lets you control such things as:
detailed explanation of each of
these options.
■ Delay Before Door Ajar Call-Back
■ Ring/Chime Cadence
■ Ring/Chime Duration
■ Door Unlock Code
■ Door Unlock Duration
■ Enable Door Code
■ Door Ajar Mode
■ Forced Disconnect Time-Out
■ Reset Options to Factory Defaults
Installation - No Dedicated Trunk/Station Port
6-5
Port Saver or Trunk Saver Mode Installation
Refer to the following instructions for Port Saver Mode or Trunk
Saver Mode installation.
Port Saver Mode
Follow the steps below to set the AT&T Door Phone Controller
for Port Saver Mode.
CAUTION: Never connect an AT&T DOOR PHONE
CONTROLLER with the DIP Switches optioned for TRUNK
access to a STATION LINE! Doing so may cause damage
to the STATION LINE and/or the AT&T DOOR PHONE
CONTROLLER!
1.
Select Option Selection Mode by setting position 8
of the AT&T Door Phone Controller DIP switch (see
Access the trunk (allocated for the AT&T Door Phone
Controller), and make connection to the door speaker by
dialing “1” or “2” within 4 seconds. At this point you
must enter “##3” on the telephone keypad (Option
Selection Mode is active as soon as you hear a distinc-
tive dial tone – if you don’t hear a distinctive dial tone,
check to see if switch 8 is DOWN).
2.
Any or all options may be
reselected in any order.
The Forced Disconnect
Time-out option does not apply
when setting options (unless 2
minutes elapse without a
Touch-Tone selection).
4. To exit Option Selection Mode, press “##3” on the
telephone keypad. You will hear 2 beeps. Hang up
phone.
5. Set position 8 of the AT&T Door Phone Controller DIP
switch back to the OFF position.
6-6
Installation - No Dedicated Trunk/Station Port
Trunk Saver Mode
Follow the steps below to set the AT&T Door Phone Controller
for Trunk Saver Mode.
CAUTION: Never connect an AT&T DOOR PHONE
CONTROLLER with the DIP Switches optioned for TRUNK
access to a STATION LINE! Doing so may cause damage
to the STATION LINE and/or the AT&T DOOR PHONE
CONTROLLER!
1. Select Option Selection Mode by setting position 8
of the AT&T Door Phone Controller DIP switch (see
Access the Trunk (allocated for AT&T Door Phone Con-
troller) and make connection to the door speaker by
“Hook-Flashing” the phone. At this point you must enter
“##3” on the telephone keypad (Option Selection Mode
is active as soon as you hear a distinctive dial tone – if
you don’t hear a distinctive dial tone, check to see if
switch 8 is DOWN).
2.
Any or all options may be
reselected in any order.
The Forced Disconnect
Time-out option does not apply
when setting options (unless 2
minutes elapse without a
Touch-Tone selection).
To exit Option Selection Mode, press “##3” on the
telephone keypad, you will hear 2 beeps. Hang up
phone.
4.
5. Set position 8 of the AT&T Door Phone Controller DIP
switch back to the OFF position.
Installation - No Dedicated Trunk/Station Port
6-7
Table 6-1. AT&T Door Phone Controller Option Selection Information
Mode Option/
Verify
Listen
For
Listen
For
Options
Press
Press
Default
To Select Option
To Verify
Single 000 to 255 for 0 to 255
Double
Beep
30 sec.
Delay Before
Door Ajar
Call-back
00
01
seconds of delay after strike
Beep
plate release stops until
AT&T Door Phone Controller
calls back to indicate door is
ajar
To Select Option
To Verify
Single 24 (for 2 sec. on 4 sec. off
Double
Beep
Ring/Chime
Cadence
10
2 sec./
4 sec.
Beep
cadence)
or
11
15 (for 1 sec. on 5 sec. off
cadence)
To Select Option
To Verify
Ring/Chime
Duration
20
21
Single 00 to 99 (0 to 99 second(s)
ring/chime)
Beep
Double
Beep
30 sec.
To Select Option
To Verify
Single 4 digits (first digit must be
Door Unlock
Code
30
31
Double
Beep
6736
“OPEN”
0,3,4,5,6,7 or 8;
Beep
remaining digits can be set
from 0 to 9)
To Select Option
To Verify
Door Unlock
Duration
40
41
Single 00 to 99 (door lock active
Beep time in sec.)
4 sec.
Double
Beep
To Select Option
To Verify
1
0
Enable door code
Disable door code
Enable Door
Code
50
51
Single
Beep
Double
Beep
1
(Enabled)
For callback after strike
plate release only
For callback anytime
door is opened
To Select Option
To Verify
Door Ajar
Mode
50
51
Single
Beep
2
3
Double
Beep
2
Forced
Disconnect
Time-Out
To Select Option
To Verify
60
61
Single 010 to 255 (unit disconnects
in 10 to 255 sec.)
Double 120 sec.
Beep
Beep
To Select Option
To Verify
Single ## (to restore factory default
conditions)
Reset Options
to Factory
Defaults
70
71
Double
Beep
N/A
Beep
NOTE: The Door Ajar Delay (Option Selection) will begin when the call to the door speaker is disconnected.
6-8
Installation - No Dedicated Trunk/Station Port
Operation – Basic Door Answer Function
Visitor Presses Door Speaker Button
When a visitor presses the door speaker push button, the
AT&T Door Phone Controller will signal the telephone
equipment inside your building to ring, and activate an auxiliary
alert (door-bell/chime) (optional). Any additional presses on the
door speaker push button will be ignored (with the exception
that a confirmation tone will still be sent to the speaker when
the door button is pressed).
Answering a Call From the Door Speaker
When a person inside the building hears the telephone ring
and/or the door bell/chime sound, he can respond by answer-
ing the ringing phone. At this point, the AT&T Door Phone
Controller will establish two-way communication with the door
speaker. To open the door, the person inside the building either
enters the Door Code on the telephone’s keypad or presses
the customer provided door-unlock push button. Either of these
actions will activate the customer provided electric door strike
plate device.
As an alternative response to hearing the telephone or door
bell/chime, the person inside the building can press the door-
unlock push button which will stop the ringing and will open the
door. This allows the door to be unlatched without the use of a
phone.
Installation - No Dedicated Trunk/Station Port
6-9
Calling the Door Speaker From Inside the Building
Your PBX must be capable of
relaying the hook-flash from the
station set to the trunk port.
To initiate a call to the door in the Trunk Saver mode, the
person within the building simply takes the telephone off-hook,
accesses the trunk connected to the AT&T Door Phone
Controller, and hook-flashes the telephone within the first
5 seconds. At this point, there will be direct two-way
communication from within the building to the door speaker.
To initiate a call to the door in the Port Saver mode, the person
within the building simply takes the telephone off-hook,
accesses the trunk connected to the AT&T Door Phone
Controller, and dials “1” within the first 4 seconds. At this point,
there will be direct two-way communication from within the
building to the door speaker. (Alternatively, the person may dial
a “9” within the first 4 seconds after accessing the trunk in
order to be immediately connected to the C.O. line.)
Telephone Line In Use When a Visitor Presses Door
Speaker Button
If a visitor presses the door speaker button while an existing
Once the doorbell push button
is pressed, you can "Hook-
Flash" to the door speaker and
then back to the original call
call is already taking place on the line, the AT&T Door Phone
Controller will generate a “door alert” signal to indicate a visitor
needs attention at the entrance. The person using the line can
only once, unless the push
button is pressed again.
hook-flash the phone and be in direct two-way communication
to the door speaker. The other party will be placed on hold. At
this point, normal AT&T Door Phone Controller functions can
take place. When the door phone functions have been
If you forget to hook-flash back
to the original call, the AT&T
Door Phone Controller will call
you back.
completed, i.e., door has been remotely opened, hook-flashing
phone again (or pressing 9) will return line to original call. This
feature operates much like a call-waiting function.
6-10
Installation - No Dedicated Trunk/Station Port
Telephone Line In Use With Door When a Call Arrives
If there is a call in progress between the door speaker and a
station user and a call (C.O.) comes in, the person inside the
building (not the door speaker) will hear a call waiting tone. The
station user can hook-flash the phone (or dial 9) and
communicate with the incoming caller. When the call is
complete, the station user hangs up the phone. To speak with
the door phone again, the station user must either hook-flash
the phone (within 4 seconds of picking up the receiver) if
installed for Trunk Saver Mode or dial “1” if installed for Port
Saver Mode.
Placing a Call Through the C.O. From Inside Building
To initiate a call through the C.O. in the Trunk Saver Mode, the
person within the building simply takes the telephone off-hook,
accesses the trunk connected to the AT&T Door Phone
controller, and then dials the desired phone number. This is
normal procedure for placing an outside call.
To initiate a call through the C.O. in the Port Saver Mode, the
person within the building simply takes the telephone off-hook,
then accesses the trunk connected to the AT&T Door Phone
Controller. At this point the caller will hear a dial tone from the
Door Phone Controller. Dialing a “9”, or waiting 4 seconds, will
switch the caller to the C.O. and the regular phone number is
dialed.
Installation - No Dedicated Trunk/Station Port
6-11
Troubleshooting Procedures
Table 7-1. Troubleshooting Procedures
Possible Cause
Trouble
Possible Solution
Check power connection.
If power connection is good,
then return for repair.
LED “off” constantly
Brown-out condition or software
frozen.
LED “on” constantly
Unplug and plug back in.
Internal software error; may still
work.
LED blinking more than four
times a second
Unplug and plug back in; if
problem continues return for
repair.
Volume control turned down or
DIP switches incorrectly set for
mode of operation.
Talkback volume, but no
speaker volume
Verify setting of controls and
DIP switches.
Volume control turned down.
Speaker volume, but no
talkback volume
Verify setting.
Shorted or open speaker lead
connection.
No page or talkback volume
Remove short or open.
Check forced disconnect
time-out selection.
Unit disconnects after a
certain time
Change time-out (option
selection).
DIP switches incorrect for mode
of operation. Telephone system
returns dial tone after Door
Phone goes on-hook.
Verify Mode of operation.
Program telephone system for
no dial tone on this extension.
Dial tone heard from the
speaker
DIP switch incorrect.
Cannot hear your own voice
in telephone ear piece
Correct.
Correct.
Plugged wires into wrong jack.
Forced disconnect timeout set
to low.
Station mode seizes line then
disconnects before AT&T
Door Phone Controller is
accessed
Enter Option Selection Mode
(##3), and enter new Forced
Disconnect Timeout Duration.
Station line plugged into J2.
J1 and J2 swapped.
Correct, move to J1.
Cannot access AT&T Door
Phone Controller in trunk
saver mode
Check connections and correct
if needed.
Bad door ajar switch.
Fix or adjust.
Fix.
Getting door-ajar callback
when door is actually closed
Open door ajar switch wiring.
7-2
Troubleshooting and Maintenance
Table 7-1. Troubleshooting Procedures (Continued)
Trouble
Possible Cause
Possible Solution
Getting door-ajar callback
when door ajar switch is not
used
Missing jumper on terminal
block.
Jumper pins 8 & 9 of terminal
block.
Receive C.O. call waiting
tone when accessing the
Door Phone Controller but
cannot dial and/or hook-flash
to connect to call
Door Phone Controller optioned
for dedicated mode instead of
Trunk Saver or Port Saver Mode.
Verify DIP switch positions.
Use in dedicated mode.
PBX does not relay the hook-
flash.
Cannot open door remotely
using Touch Tone door
unlatch function
Door Unlock option disabled
If error tone, verify Door Open
Code and Door Unlock enable
option.
or
Wrong Door Code.
Check all wiring from AT&T
Door Phone Controller to electric
strike plate device (see
Disconnect wires from the
terminal block “Door Unlatch
Contacts.” Use volt/ohm meter
to check continuity between
NO and C terminals while
activating Touch-Tone door
unlatch function. If continuity
test fails, return AT&T Door
Phone Controller for repair.
manufacturer’s instructions).
Cannot open door remotely
using remote door open
button
Check all wiring from AT&T
Door Phone Controller to electric
strike plate device, also check
operation of electric strike plate
device (see manufacturer’s
instructions).
Disconnect wires from the
terminal block “Remote Open
Button” and “Door Unlatch
Contacts.” Use volt/ohm meter
to check continuity between
both wires from the remote
open button while activating
the button. If continuity test of
button is good, button is OK.
Now reconnect button wires to
“Remote Button Contacts,”
and check continuity of “Door
Unlatch Contacts” (between
NO and C) while activating
remote door open button. If
continuity test fails, return
AT&T Door Phone Controller
for repair.
Troubleshooting and Maintenance
7-3
Table 7-1. Troubleshooting Procedures (Continued)
Trouble
Possible Cause
Possible Solution
Improper wiring to existing door
strike device. May be caused
by improper connection and use
of NO (Normally-Open), NC
(Normally Closed), and C
Cannot open door remotely
using either Remote Door
Open Button or the Door
Code
Verify all connections when
connecting the door strike
contacts on the AT&T Door
Phone Controller to existing
door open buttons. Make sure
of the following:
(Common) door latch relay
contacts, especially when
interfacing these contacts to
existing door configurations.
1. The NO and C contacts
are connected in parallel to a
normally-open button.
2. The NC and C contacts
are connected in series to a
normally-open button.
Incorrect or inappropriate values
were entered.
Selected options are not
operating as expected
Use Verify mode to confirm
selected options without
changing the values.
Carefully consider the
“consequences” of options
chosen.
Maintenance
Periodic maintenance is not required.
Units requiring repair are returned to AT&T for service.
7-4
Troubleshooting and Maintenance
Appendix A—DIP Switch Settings
Positions
the DIP
Switch
Setting
The AT&T Door Phone Controller’s basic operating modes are
selected on the 8-position DIP switch at the front of the unit
way the AT&T Door Phone Controller will interface with your
telephone equipment. Position 8 is used to access Option
Selection Mode. Positions 6 & 7 are not used. The definition of
each switch position is given below:
NOTE: All switches are OFF
when shipped from the
factory.
Switch 1
Selects between Trunk Access and Station Access. Trunk
Access = OFF; Station Access = ON.
Switch 2
Selects between Dedicated Trunk or Shared Trunk. This switch
only has meaning when Trunk Access is selected with
Switch 1. Shared Trunk = OFF; Dedicated Trunk = ON.
Switch 3
Selects between Trunk Saver or Port Saver. This switch only
has meaning when Trunk Access is selected with Switch 1 and
Shared Trunk is selected with Switch 2. Trunk Saver= OFF;
Port Saver = ON.
Switch 4
Selects between Loop Start and Ground Start. This switch only
has meaning when Trunk Access is selected with Switch 1.
Loop Start = OFF; Ground Start = ON.
Switch 5
Selects between Auxiliary Alert or Ringdown. This switch only
has meaning when Station Access is selected with Switch 1.
Auxiliary Alert = OFF; Ringdown = ON.
DIP Switch Settings A-1
Switch 6
Not used.
Switch 7
Not used.
Switch 8
Selects between Option Selection Mode and Normal Operation.
This switch acts as a Option Selection security switch. If this
switch is ON, any user can activate Option Selection Mode by
keying in “##3” on a touch-tone telephone set which connects
directly to the AT&T Door Phone Controller. When this switch is
OFF, Option Selection Mode cannot be activated. Normal
Mode = OFF; Option Selection Mode = ON.
A-2
DIP Switch Settings
Appendix B—Option Selection Mode Definitions
The information below provides detailed information regarding
each of the settable options for the AT&T Door Phone
Controller.
Provides an alternate ring (on/off) cycle from how it would ring
for a normal call. For instance, you can configure the telephone
to ring for 2 seconds and then be silent for 4 seconds, or ring
for 1 second and then be silent for 5 seconds.
Ring/Chime Cadence
This option provides a maximum duration of telephone ringing
cycles (in seconds) before the AT&T Door Phone Controller will
disconnect.
Ring/Chime Duration
Door Unlock Code
This option determines what your door unlock combination will
is
be. The default is set for 6736, but for security reasons it
recommended you change this to your own four-number
combination.
This option determines the amount of time the door unlock
function will be activated. The default is 4 seconds.
Door Unlock Duration
Enable Door Code
This option can be set so the door access code is disabled.
Once it is disabled, entering the door unlock code will not
provide a door unlock function.
This option provides the choice of either having the Door Ajar
call back any time the door is opened, or only after it has been
opened via the strike plate release. Note: When the Door Ajar
switch senses that the door has been opened and closed
again, the door open relay will cease being energized.
Door Ajar Mode
This option sets the maximum time in which two-way
communications can take place between the door speaker and
the telephone. Setting this option to less than 30 seconds is not
advised.
Forced Disconnect
Timeout
Option Selection Mode Definitions
B-1
This option is useful when current option selections are
unknown. Note that this function will reset the Door Unlock
Code to the default value, but it will not reset “Phone Number
Storage Memory 1” or “Phone Number Storage Memory 2”
(see below). Defaults to dialing phone number #1.
Reset Option
Selections to Factory
Defaults
This option is used in what is called “Ringdown Mode” to
auto-dial a particular extension or outside-line phone number.
The AT&T Door Phone Controller has two memory locations for
holding user stored telephone numbers. Phone numbers can
be for telephones within the same building or off-premises.
These memory locations are used exclusively in Ringdown
Mode. Only one memory location is active at a time. To select
the active location for the phone number, a telephone
Phone Number
Storage Memory 1
connection to the AT&T Door Phone Controller must be made
(by calling the extension number of the Door Phone). Once
connected dial in “##1”, this selects Memory Location 1; if you
were to dial in “##2”, you would select Memory Location 2.
See above explanation.
Phone Number
Storage Memory 2
This option determines the length of time allowed for the door
to shut after it has been opened by the strike plate release. If
the door is still ajar at the end of this period, the controller will
call back and an alarm tone will be heard in the receiver when
the phone is answered.
Delay Before Door
Ajar Call Back
B-2
Option Selection Mode Definitions
Appendix C—Specifications
Electrical
The Door Answer Controller meets:
Standards
■ U.L. listing requirements
■ F.C.C. part 15, class B requirements
■ F.C.C. part 68 requirements
Your AT&T Door Phone Controller complies with the ESD
requirements in BELL Pub 48002.
Electrostatic Discharge
Power Supply
All user accessible connectors and controls have electrostatic
discharge protection.
The AT&T Door Phone Controller is powered by an UL listed
wall mount transformer with a strain relieved cord.
It functions over an input power range of 96 VAC to 129 VAC.
Your AT&T Door Phone Controller has a green LED power
indicator.
A flashing state of 2.5 per second indicates normal power to
the unit and normal microprocessor operation.
■
■
■
A constant ON state indicates a brown-out condition or
microprocessor failure.
A constant OFF state indicates there is no power to the unit.
Page and Talk-Back
Amplifier
Paging output power is 2 watts (continuous) @ 3.35 Vrms (sine
wave). Talk-back input sensitivity:
speaker leads, tip and ring output
with 600 microVrms at the
level will be -17 dBm.
Auxiliary Alert
Relay Contact Closures rated at 1
Relay Contact Closures rated at 2
amp.
Door Latch Contacts
amps.
Specifications
C-1
Your AT&T Door Phone Controller provides a ring generator
signal which can ring devices that respond to either 20 Hz or
60 Hz frequencies. The ringer will automatically adapt to a 50
Hz line by ringing at 25 Hz.
Ring Generator
A Ringer Equivalence (REN) of 2 is supported by the AT&T
Door Phone Controller.
Input has a REN of 0.5, Type B.
C.O. Line Jack
Mechanical
The AT&T Door Phone Controller’s control unit PCB is
mounted in a molded plastic enclosure with a metal back panel.
The front panel is protected by a flip down cover. You have
access to controls and connections on the front panel and back
panel.
The front panel controls and indicators consist of:
■ one page volume control
Front Panel
Back Panel
■ one talkback volume control
■ one 8 position DIP switch
■ one power indicator (green LED)
The back panel connections consist of:
■ one strain relieved cord approximately 6 feet in length
attached to a wall mount transformer
■ one RJ11 jack for the telephone/PBX interface
■ one RJ11 jack for Central Office interface
■ one connector mounted terminal strip.
Length: 10.5'', Width: 9.5'', Height: 2.5'', Weight: 5.5 Lbs.
Dimensions and Weight
C-2
Specifications
Appendix D—Using the Door Phone Controller With
An Answering Machine
Installation Information
This Appendix provides two methods for configuring an
answering machine to the AT&T Door Phone Controller. The
first method diagrams how to connect the AT&T Door Phone
Controller with an answering machine so that only regular
telephone calls are answered by the answering machine (see
answering machine to answer both regular telephone calls and
When configuring the AT&T
Door Phone Controller to
answer both the door and
telephone calls, be sure to
change your outgoing message
CAUTION: When using your answering machine to
answer both door and telephone calls, make sure to set
your answering machine to allow for a limited length in-
coming message. Do not use an answering machine that
cannot limit the incoming message length.
accordingly.
Using With an Answering Machine
D-1
AT&T DOOR PHONE CONTROLLER
(SHARED TRUNK MODE)
TYPICAL
ANSWERING MACHINE
TO J2
CONNECTOR
TO J1
CONNECTOR
TO TEL.
LINE JACK
TO TEL.
SET JACK
TO PHONE C.O.
TELEPHONE OR
TELEPHONE SYSTEM TRUNK
Figure D-1. Installation Method Used For Answering Only Telephone Calls
AT&T DOOR PHONE CONTROLLER
TYPICAL
(SHARED TRUNK MODE)
ANSWERING MACHINE
TO J2
CONNECTOR
TO J1
CONNECTOR
TO TEL.
LINE JACK
TO TEL.
SET JACK
CAUTION: SET
ANSWERING MACHINE
FOR A LIMITED LENGTH
INCOMMING MESSAGE
ONLY!
TO
PHONE C.O.
TELEPHONE OR
TELEPHONE SYSTEM
TRUNK
Figure D-2 Installation Method Used For Answering Both Door and Telephone Calls
.
D-2
Using With an Answering Machine
Appendix E—Auxiliary Alert Option
Installation Instructions
The following instructions utilize the WP91683 L1 Power
Supply for the AT&T Door Phone Controller external alert
feature.
for providing
The WP91683 L1 Power Supply is the interface
48VDC to operate external alert features for the
APPLICATION
INFORMATION
AT&T Door
Phone Controller such as bells, horns, lamps, strobes, and
chimes.
The WP91683 L1 Power Supply is a plug-in power supply
capable of providing 48VDC at up to 200 milliamps. The power
supply operates from a 115/120 volt AC standard single or
duplex receptacle.
The AT&T Door Phone, in conjunction with a telephone system,
provides a means to alert a customer that a doorbell button has
been pressed. In response the customer can answer and talk
to the door from a telephone within the customers premises.
HOW IT WORKS
The alerting device function can be provided by an external
alert device powered by the WP91683 L1 Power Supply. The
AT&T Door Phone’s AUX. ALERT contact closure is used by
the WP91683 L1 Power Supply to provide 48 Volts DC to
activate the external alert device.
These instructions apply to the use of a four-conductor modular
INSTALLATION
cord
only.
1.
Locate the WP91683 L1 Power Supply as close as pos-
sible to the AT&T Door Phone Controller (the nearest
wall receptacle, DO NOT PLUG IN YET).
2. Run a standard 2-pair wire DIW or equivalent between
the AT&T Door Phone Controller and a 103A connect-
ing block. Connect jack on the 103A block to the jack
Auxiliary Alert Device Connections
E-1
marked “Control” on the WP91683 L1 Power Supply
A) Connect one end of the wire to the AT&T Door Phone
Controller as follows:
Connect the black and yellow leads to the Aux. Alert
terminals of the Door Phone Controller.
B) Connect the other end of the wire to the 103A
connecting block. Connect the leads as follows:
On the 110-type connector, connect Terminal 2 to the
black wire, and connect Terminal 6 to the yellow wire
Place alerter where desired. Run 2-pair DIW from
alerter (signal) to power supply. Connect 4-conductor
modular plugs to both ends of 2-pair wire DIW as fol-
lows:
A standard 4-conductor modular
cord set can be used for limited
distances (25 feet and under)
for connections between the
WP91683 L1 Power Supply
power jack and alerter (signal)
only.
3.
Position 1 - Black Wire
Position 2 - Red Wire
Position 3 - Green Wire
Position 4 - Yellow Wire
4. Place one modular plug into modular jack on alerter
(SIGNAL).
5. Place the second modular plug into the WP91683 L1
Power Supply jack marked “POWER”.
Plug WP91683 L1 Power Supply into wall receptacle.
6.
7. Test to see that external alert is operating by pressing
the button on the AT&T Door Phone Speaker.
E-2
Auxiliary Alert Device Connections
AT&T DOOR
PHONE CONTROLLER
BACK PANEL
103A
2 PAIR DIW
OR EQUIVALENT
22-26 AWG.
CONECTOR BLOCK
CONNECTOR
1
JACK
1
2
2
BLACK
3
4
3
4
YELLOW
5
6
5
6
7
8
7
8
AT&T AUXILIARY
ALERT DEVICE
48VDC
DW4A CORD
(OR EQUIVALENT)
EXTERNAL
ALERT
SIGNAL
DW4A CORD
(OR EQUIVALENT)
POWER CONTROL
PEC 60314
COMCODE 405712928
Figure E-1. Connections For Auxiliary Alert Device
Auxiliary Alert Device Connections
E-3
—FCC Regulations and Warranty
Appendix F
FCC Regulations Pertaining to this Equipment
The AT&T Door Phone Controller generates and uses radio frequency
FCC (PART 15)
Radio Frequency
Interference
energy and if not installed and used in strict accordance with the
manufacturer’s instructions, may cause interference to radio and
television reception.
NOTE: The AT&T Door Phone Controller has been tested and
found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a
residential installation. The AT&T Door Phone Controller
generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If the AT&T Door Phone Controller does
cause interference to radio or television reception, which can be
determined by turning the AT&T Door Phone Controller unit off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
●
Reorient or relocate the radio or TV receiving antenna.
●
Relocate the unit to increase the separation with respect to the
radio or TV receiver or vice-versa.
●
Plug the unit into a different outlet so that it and the radio or TV
receiver are on different branch circuits.
●
If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user
may find the following booklet, “How To Identify and Resolve
Radio-TV Interference Problems,” helpful. This booklet was
prepared by the Federal Government Printing Office, Washington,
DC 20402. Stock order No. 004-000-00345-4.
This equipment is registered with the Federal Communications
FCC (PART 68)
Commission (FCC) in accordance with Part 68 of its Rules. The FCC
requires that the manufacturer provide you with the following
information:
FCC Regulations and Warranty
F-1
1. Connection and Use with Nationwide Telephone Network
The FCC requires that you connect your telephone equipment to the
nationwide telephone network through a modular telephone outlet or
jack. The modular telephone outlet or jack to which the equipment
must be connected is a USOC RJ11C.
If this equipment causes harm to the telephone network, the telephone
company will notify you in advance that temporary discontinuance of
service may be required. If advance notice isn’t practical, the
telephone company will notify the customer as soon as possible. Also,
you will be advised of your right to file a complaint with the FCC if you
believe it is necessary.
The telephone company may make changes in its facilities, equipment,
operations, or procedures that could affect the operation of the
equipment. If this happens, the telephone company will provide
advance notice in order for you to make the necessary modifications in
order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact your
dealer for repair and(or) warranty information. If the trouble is causing
harm to the telephone network, the telephone company may request
you remove the equipment from the network until the problem is
resolved.
Registered equipment may not be used on telephone company Coin
Telephone Lines. Equipment may be used with Party Lines in areas
where state tariffs permit such connections and when equipment is
adaptable for such use.
2. Information You May Need to Supply the Telephone Company
Upon request of your local telephone company, you are required to
provide them with the following information:
A. The lines to which you will connect the telephone equipment.
B. The FCC registration number and Ringer Equivalence Number
(REN). Both numbers are listed on the equipment label. The REN is
useful to determine how many devices you may connect to your
telephone line and still have them ring when your telephone line is
called. In most, but not all areas, the sum of all RENs per line should
be 5 or less. You may want to contact your local telephone company.
The local telephone company must also be notified upon final
disconnection of the equipment from the local telephone company
lines.
F-2
FCC Regulations and Warranty
Warranty Information
Limited Warranty and Limitation of Liability
AT&T warrants to you that the product will be free from defects
in material and workmanship when title passes to you. If you
notify AT&T that the product has failed to operate as warranted
within one year of the date title passes to you, AT&T will, at its
option, repair or replace the component or components of the
product that failed to operate as warranted. Any repair or
replacement components may be new or refurbished and will
be provided on an exchange basis. If AT&T determines that the
product cannot be replaced, AT&T will refund the purchase
price to you.
If you purchased the product directly from AT&T, AT&T will
perform warranty repair on your premises in accordance with
the terms and conditions of AT&T’s “Business Day” or
“Around-the-Clock” warranty plans. The details of AT&T’s
warranty plans may be obtained from AT&T. If you purchased
the product from an authorized dealer, you will be covered by
AT&T’s authorized dealer warranty plan during the warranty
period. Contact your authorized dealer for details of AT&T’s
authorized dealer warranty plan. AT&T’s obligation to repair,
replace or refund as set forth above is your exclusive
remedy.
The limited warranties provided above do not cover damages,
defects, malfunctions or product failures caused by:
■
■
■
■
Failure to follow AT&T’s installation, operation or
maintenance instructions;
Unauthorized modification or alteration of the product or its
components;
acts of persons not
Product abuse, misuse or the negligent
under the reasonable control of AT&T;
Actions of third parties and acts of God other than power
surges (e.g., lightning).
FCC Regulations and Warranty
F-3
This limited warranty applies only to the product purchased
directly from AT&T or purchased directly from an authorized
AT&T dealer. This limited warranty does not apply to products
purchased or operated outside the United States.
You may be required to provide AT&T with proof of purchase
before AT&T will perform any warranty repair or provide any
warranty replacements.
EXCEPT AS SPECIFICALLY SET FORTH ABOVE, AT&T, ITS
AFFILIATES, SUPPLIERS AND DEALERS MAKE NO
WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY
DISCLAIM ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
EXCEPT FOR PERSONAL INJURY, THE LIABILITY OF AT&T,
ITS AFFILIATES, SUPPLIERS AND DEALERS FOR ANY
CLAIM, LOSS, DAMAGE OR EXPENSE FROM ANY CAUSE
WHATSOEVER, REGARDLESS OF THE FORM OF THE
ACTION, WHETHER IN CONTRACT, TORT OR OTHERWISE,
SHALL NOT EXCEED THE LESSER OF DIRECT DAMAGES
PROVEN OR THE REPAIR OR REPLACEMENT COST OF
THE SYSTEM OR THE SYSTEM’S PURCHASE PRICE. IN
NO EVENT SHALL AT&T, ITS AFFILIATES, SUPPLIERS AND
DEALERS BE LIABLE FOR INCIDENTAL, RELIANCE,
CONSEQUENTIAL OR ANY OTHER INDIRECT LOSS OR
DAMAGE (INCLUDING LOST PROFITS OR REVENUES
SUSTAINED OR INCURRED IN CONNECTION WITH THE
SYSTEM). THIS LIMITATION OF LIABILITY SHALL SURVIVE
FAILURE OF THE EXCLUSIVE REMEDY SET FORTH IN THE
LIMITED WARRANTY ABOVE.
F-4
FCC Regulations and Warranty
— Option Selection
AT&T
Door Phone Controller
To Select Options: (1) Set DIP switch location 8 to the ON position. (2) Dial door speaker phone number or
extension. (3) Dial ##3. (4) Program any or all of the following functions, in any order:
Listen
For
Listen
For
Mode Option/
Verify
Default
Press
Options
Press
Single 000 to 255 for 0 to 255
Double
Beep
30 sec.
To Select Option
To Verify
00
01
Delay Before
Door Ajar
Call-back
Beep
seconds of delay after strike
plate release stops until
Door Phone Controller calls
back to indicate that door is
ajar
2 sec./
4 sec.
Double
Beep
Single 24 (for 2 sec. on 4 sec. off
Ring/Chime
Cadence
To Select Option
To Verify
10
11
or
cadence)
Beep
15 (for 1 sec. on 5 sec. off
cadence)
Double
Beep
30 sec.
Single 00 to 99 (0 to 99 second(s)
ring/chime)
Ring/Chime
Duration
To Select Option
To Verify
20
21
Beep
6736
“OPEN”
Double
Beep
To Select Option
To Verify
30
31
Single 4 digits (first digit must be
Door Unlock
Code
Beep
0,3,4,5,6,7 or 8;
remaining digits can be set
from 0 to 9)
4 sec.
Double
Beep
Single 00 to 99 (door lock active
Beep
To Select Option
To Verify
40
41
Door Unlock
Duration
time in sec.)
1
Single
Beep
1
0
Enable door code
Disable door code
Double
Beep
Enable Door
Code
To Select Option
To Verify
50
51
(Enabled)
For callback after strike
plate release only
For callback anytime
door is opened
To Select Option
To Verify
50
51
Single
Beep
2
3
Double
Beep
2
Door Ajar
Mode
Single 010 to 255 (unit disconnects
Beep in 10 to 255 sec.)
Double 120 sec.
Beep
Forced
Disconnect
Time-Out
To Select Option
To Verify
60
61
Single ## (to restore factory default Double
N/A
#
Reset Options
to Factory
Defaults
To Select Option
To Verify
70
71
Beep
conditions)
Beep
To Select Option
To Verify
80
81
Single 0 to 20 numerical digits and
Double
Beep
Phone
Beep
❊ ( ❊ = 2 second pause) #
Number
Storage
Memory 1
terminates entry
Phone
To Select Option
To Verify
90
91
Single 0 to 20 numerical digits and
Double
Beep
#
Beep
❊ ( ❊ = 2 second pause) #
Number
Storage
Memory 2
terminates entry
After Selecting Options: (1) Press ##3. (2) Hang up after hearing a double beep confirmation. (3) Set DIP
AT&T
Door Phone Controller
DIP Switch Settings
NOTE: All switches are OFF
when shipped from the factory.
The Door Phone Controller’s operating modes are selected on the
8-position DIP switch at the front of the unit. Positions 1 through 5 are
used to set up the way the Door Phone Controller will interface with
your telephone equipment. Position 8 is used to access Option Selec-
tion Mode. Positions 6 & 7 are not used. Definition are given below:
Selects between Trunk Access and Station Access.
Trunk Access
Switch 1
= OFF, Station Access = ON.
CAUTION: Damage to the PBX Station Card may result if
switch position #1 is incorrectly set. Double check that switch
#1 is set to ON for Station Port Access.
position
Selects between Dedicated Trunk or Shared Trunk.
This switch only has meaning when Trunk Access
is selected with Switch 1. Shared Trunk = OFF,
Dedicated Trunk = ON.
Switch 2
Selects between Trunk Savor or Port Saver. This
switch only has meaning when Trunk Access is
selected with Switch 1 and Shared Trunk is
selected with Switch 2. Trunk Saver = OFF, Port
Saver = ON.
Switch 3
Selects between Loop Start and Ground Start. This
switch only has meaning when Trunk Access is
selected with Switch 1. Loop Start = OFF, Ground
Start = ON.
Switch 4
Switch 5
Selects between Auxiliary Alert or Ringdown. This
switch only has meaning when Station Access is
selected with Switch 1. Auxiliary Alert = OFF,
Ringdown = ON.
Not used.
Not used.
Switch 6
Switch 7
Switch 8
Selects between Option Selection Mode and Normal
Operation. This switch acts as a Option Selection
security switch. If this switch is ON, any user can
activate Option Selection Mode by keying in “##3”
on a touch-tone telephone set which connects
directly to the Door Phone Controller. When this
switch is OFF, Option Selection Mode cannot be
activated. Normal Mode = OFF, Option Selection
Mode = ON.
(See other side for DTMF Option Selection.)
© 1992 AT&T
CIC# 999-500-315
0II722050-055
All rights reserved. Printed in U.S.A.
Issue 3, November 1992
Graphics © AT&T 1988
|