T300MVi
4160 V MEDIUM VOLTAGE DRIVE
T300MVi
COMMUNICATION OPTIONS
The T300MVi drive offers a wide array of easily installed option boards.
These boards allow the user to communicate with a wide variety of
systems. Options include:
• DeviceNet
• Profibus
• Modbus RTU
• Modbus TCP/IP
• Tosline-S20
ADDITIONAL OPTIONS
The T300MVi can be supplied with additional options to expand control,
allow greater flexibility, or provide better protection for a user’s application.
These options include:
• Redundant Fans
• Drive & Motor Space Heater
• Communication Cards
• Door-Mounted Equipment: Meters, Pilot Lights,
Speed Potentiometer, & Switches
• Output dV/dT Filters for Up to 2,000 ft. of Motor Cable Length
• Direct Online Bypass
• Sinewave Output Filters
• Solid State Starter Bypass
• Reduced Voltage Autotransformer Bypass
• Sync-Xfer/Capture (Multiple Motors Synchronize Transfer & Capture)
• High Voltage Input Up to 15 kV (Requires Increase in Footprint)
• Synchronous Motor Control (AC Brushless/DC Brush Type)
• Wound Rotor Motor
OTHER SPECIAL FEATURES
• Voltage Source Inverter (VSI) with Simple & Reliable Volts/Hertz
Control or Vector Control (With or Without Encoder)
• Retrofit Ready
• Air-Cooled Solutions from 300 to 10,000 HP
APPLICABLE INDUSTRIES
APPLICABLE APPLICATIONS
• Compressors • Pumps
• Mills
• Fans
• Aggregate
• Chemical
• Mining & Minerals • Water/Wastewater
• Oil & Gas
• Pulp & Paper
• Conveyors
• Extruders
• Blowers
• Mixers
• Test Stands
• Crushers
T300MVi
2250 to
3000 to
300 to 600 HP
700 to 1000 HP
1250 to 2000 HP
4000 to 6000 HP
7000 HP* 8000 to 10000 HP*
MODEL RANGE
Voltage Rating
2500 HP
3500 HP
4160 VAC
103.7 x 164 103.7 x 174
103.7 x 307.5
x 60 in.
103.7 x 402.5
x 60 in.
103.7 x 48 x 48 in.
6,200 lbs.
103.7 x 60 x 48 in. 103.7 x 122 x 43.4 in.
7,600 lbs. 12,500 lbs.
103.7 x 222 x 49.5 in.
27,750 lbs.
Dimensions (H x W x D)
Weight
x 49.5 in.
x 49.5 in.
16,500 lbs.
19,000 lbs.
37,500 lbs.
868
64,800 lbs.
37 50 62 74 87 99 112 124 155 186 217 248 279
310
372
434 496 558 620 682 744
992 1100 1240
8000 9000 10000
Current Rating (A):
Nominal HP** (4160 V)
300 400 500 600 700 800 900 1000 1250 1500 1750 2000 2250 2500 3000 3500 4000 4500 5000 5500 6000
7000
POWER REQUIREMENTS
Input Tolerance
Voltage: 10%; Frequency: 5%
Main Circuit
Three-Phase 4160 V; Integrated 24-Pulse Copper-Wound Isolation Transformer; Five-Level NPC Medium Voltage IGBT Output
Control Circuit
Output Frequency
Integral to Main Transformer; Includes 460 V & PT for 120 V Control
0 to 120 Hz
CONTROL SPECIFICATIONS INPUT
Control Method
Five-Level Pulse-Width Modulation (PWM) Output Control with Neutral-Point Clamping (NPC)
V/Hz Control
V/Hz, Sensorless Vector Control, Variable Torque, Closed-Loop Vector Control, & Constant Torque (Optional)
Fixed at 2 kHz
PWM Carrier Frequency
Frequency Setting
Speed Regulation
4 to 20 mA, 0 to 10 VDC Serial Communication Input, & Rotary Encoder Integrated into EOI
Open Loop: Up to 0.5%; Closed Loop: Up to 0.1%
Main Protective Functions
Overload Current Rating
Current Limit, Overcurrent, Overload, Undervoltage, Overvoltage, Ground Fault, CPU Error, & Soft Stall
100% Continuous; 115% for One Minute Every 20 Minutes (1000, 2000, & 6000 HP at 110%)
CONTROL INTERFACE
Digital Input
Eight Discrete Input Terminals with Programmable Functions
Digital Output
Six Available Digital Programmable Outputs (One Used Internal to Drive)
Analog Input
Two Selectable Currents (0/4 to 20 mA) or Voltage (0 to 10 VDC) Input Signals
Eight Selectable Currents (0/4 to 20 mA) or Voltage (0 to 10 VDC) Output Signals with Programmable Function
Profibus, Modbus RTU, Modbus, TCP/IP, TOSLINE-S20, & DeviceNet
Analog Output
Communication Ports
Standard Pad-Lockable Input Fuse Disconnect Switch with Vacuum Contactor, Interlocked Doors, & Viewing Window
SAFETY FEATURES
ELECTRONIC OPERATOR INTERFACE (EOI)
Display
6-Line x 20-Character Graphical Plain-English Back-Lit LCD Display for Programming, Monitoring, & Diagnostics
LED Indicators
Keys
Run (Red)/Stop (Green) & Local (Green)
Local/Remote, Enter, Mon/Prg, Esc, Run, & Stop/Reset
Monitoring
Frequency Command Screen; Multiple Parameters Displayed: Motor Current, Motor Speed, Motor Voltage, DC Voltage, Input Voltage, Output
Voltage, Run Time, Output Power, Motor kW, Motor kWH, Motor kVAH, Motor kVAR, & On-Time Control Power
CONSTRUCTION
Enclosure
ANSI-61 Gray; NEMA 1 Ventilated, & IP20 Per IEC-60529; Gasket & Filter; Free-Standing; Front-Access Only
Top/Bottom Access for Input/Motor Cables
Power Cables
Cooling
Forced-Air Cooled (Redundant Fan Option)
Standards & Compliances
NEC, NEMA, UL, ULC, ANSI, & American Recovery & Reinvestment Act Compliant
AMBIENT CONDITIONS
Ambient Temperature
Altitude
0 to 40°C (50°C Option Available)
3,281 ft. Above Sea Level (Up to 14,764 ft. Option Available)
95% Maximum (Non-Condensing)
Humidity
Installation
Indoor; No Direct Sunlight; Protect from Corrosive Gases
All Information Subject to Change
*Models Not UL Listed
**Typical HP Rating of a 4-Pole Motor; Contact Factory for Applications on Constant Torque Loads
TOSHIBA INDUSTRIAL PRODUCTS:
• Adjustable Speed Drives
• Motors
• Motor Controls
• Instrumentation & PLCs
• Uninterruptible Power Systems
© 2012 Toshiba International Corporation • Industrial Division • 13131 West Little York Road • Houston, Texas 77041 USA • Tel +713-466-0277 US 1-800-231-1412 • Rev. 120221
|