TEXAS MEMORY SYSTEMS, INC.
RamSan-210 User’s Manual
Version 1.1
- i -
Table of Contents
Preface................................................................................................................................. 1
Document Overview....................................................................................................... 1
Conventions .................................................................................................................... 1
Chapter 1 – Introduction.................................................................................................. 2
1.1
1.2
1.3
1.4
Overview............................................................................................................. 2
System Components............................................................................................ 2
Power Requirements ........................................................................................... 3
Non-Volatility..................................................................................................... 3
Chapter 2 – Installation.................................................................................................... 5
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
Electro-Static Discharge Warning ...................................................................... 5
Battery Warning.................................................................................................. 5
System Inspection............................................................................................... 5
Rack Mounting.................................................................................................... 7
Connecting the Fibre Channel Ports ................................................................... 7
Connecting the Power Supplies .......................................................................... 7
Turning on the System........................................................................................ 9
System Initialization........................................................................................... 9
Chapter 3 – Using the Front Panel................................................................................. 10
3.1
3.2
3.3
3.4
3.5
Overview........................................................................................................... 10
Menu System Layout ........................................................................................ 11
Ethernet Setup ................................................................................................... 11
Manual Shutdown............................................................................................. 12
System Monitoring............................................................................................ 13
Chapter 4 The Management Control Port (MCP) ......................................................... 15
4.1
4.1.1
4.1.2
4.2
4.3
4.4
4.5
Connecting to the MCP..................................................................................... 15
RS232 Serial Port...................................................................................... 15
Ethernet ..................................................................................................... 15
Connecting using a terminal program............................................................... 15
Connecting using telnet..................................................................................... 15
Logging into the system.................................................................................... 15
MCP Commands............................................................................................... 16
EXIT.......................................................................................................... 16
HELP......................................................................................................... 16
CONFIGSYS ............................................................................................ 16
FIRMWARE............................................................................................. 16
IPCONFIG................................................................................................ 16
LUNCONFIG............................................................................................ 18
MANAGE................................................................................................. 18
PASSWORD............................................................................................. 18
PERFORMANCE..................................................................................... 19
4.5.1
4.5.2
4.5.3
4.5.4
4.5.5
4.5.6
4.5.7
4.5.8
4.5.9
4.5.10
4.5.11
4.5.12
PORTCONFIG ......................................................................................... 19
POWEROFF ............................................................................................. 19
REBOOT................................................................................................... 19
- iii -
4.5.13
4.5.14
RESET ...................................................................................................... 19
STATUS.................................................................................................... 20
Chapter 5 Chapter 5– Hot Swap Components............................................................... 21
5.1
5.2
5.3
Hot Swapping Power Supplies.......................................................................... 21
Hot Swapping Disk Drives ............................................................................... 22
Hot Swapping Fans ........................................................................................... 22
Chapter 6 – Batteries ..................................................................................................... 24
Chapter 7 – Troubleshooting ......................................................................................... 25
Chapter 8 – Specifications............................................................................................. 26
8.1
8.2
8.3
8.4
Physical Characteristics .................................................................................... 26
Operating Environment..................................................................................... 26
Non-operating Environment ............................................................................. 26
Warranty............................................................................................................ 26
Appendix A – RamSan-210 Replacement Parts ............................................................... 27
- iv -
Figures
Figure 1 RamSan-210 Layout............................................................................................. 6
Figure 3-2 RamSan-210 Front Panel................................................................................ 10
Figure 5-3 Default LUN configuration............................................................................. 21
Figure 5-4 Reconfigured LUN mapping........................................................................... 21
- v -
Preface
Document Overview
This document provides operating procedures for the RamSan-210. It covers installation,
management, and troubling shooting issues.
Conventions
The following textual conventions are used in this document:
Select
Front panel button descriptions
Ethernet Setup
lunconfig
Front panel text (menu items)
Management port (serial/telnet) commands and text.
- 1 -
Chapter 1 – Introduction
1.1 Overview
The RamSan-210 is a solid-state disk. The system uses SDRAM (memory) as primary
storage. The system is non-volatile because all writes are mirrored to two internal hard
disk drives and stored in memory. All reads occur from memory. This architecture
provides uncompromised performance and security.
The RamSan-210 is designed to be highly available and fault tolerant. The system is
more highly available than RAID or JBOD systems because the primary storage media is
SDRAM. There are no moving parts required to store data on SDRAM. Additionally,
SDRAM has a very high mean time between failures (as high as several hundred years)
according to some studies. The mechanical components in the RamSan-210 are
redundant and hot swappable.
The RamSan-210 is a complement to existing disk drives, JBOD or RAID in performance
sensitive applications. The RamSan-210 appears as another SCSI disk drive that has
been attached to the server. For some applications, the RamSan-210 is the only storage
system that will be required. For applications that store terabytes of data, the RamSan-
210 will be added to a system that includes RAID or JBOD.
The RamSan-210 can be connected via Fibre Channel to host servers, NAS filers or to
storage network switches and hubs. If you have specific questions about compatibility,
please see or contact Texas Memory Systems directly.
The RamSan-210 can be used in a variety of applications. If your application is slowed
down by hard disk drives, there is a good chance that the RamSan-210 can speed it up.
1.2 System Components
The system components for the RamSan-210 include:
·
·
·
·
·
·
·
·
·
·
Main system memory ranging from four gigabytes to thirty-two gigabytes
Either two or four one gigabit Fibre Channel ports
Dual, redundant hot-swappable power supplies
Dual, redundant hot-swappable 10,000 RPM hard drives
Dual, redundant batteries
Dual, redundant hot-swappable fans
Ethernet monitoring port
Serial monitoring port
Front panel display for monitoring and configuration
SNMP based monitoring
- 2 -
1.3 Power Requirements
The RamSan-210 requires 150 watts of power for a fully loaded system. The RamSan-
210 includes two power supplies. Only one power supply is needed to run the system.
The power supplies are auto-ranging (they will accept either 110 or 220 power).
Each power supply is connected to an internal battery. The batteries provide at least one
hour of operation after a power failure. The power supplies and the batteries are linked.
In other words, if a power supply is not plugged into the system, its attached battery will
not work. If the power supply is broken its attached battery will not work. If the power
supply is plugged in and functional, the battery should operate properly. In the event one
battery or power supply is disabled, the other functional power supply and battery
combination will be able to handle system operation. Power supply temperature can be
monitored from the system monitoring software.
If power is lost, the system will operate for a user-defined number of minutes before
shutting down. When the system shuts down it will clear the write buffers by writing to
the mirrored internal disk drives.
When power is restored, the RamSan-210 will resume normal operations after restoring
system memory with the data from the disk drives. The system will also begin
recharging the batteries. Battery charge levels can be monitored using the bundled
remote monitoring software.
1.4 Non-Volatility
By utilizing internal hard drives and batteries, the RamSan-210 combines the
performance of SDRAM storage with the non-volatile nature of hard disk drives. The
RamSan-210 is equipped with dual, redundant, hot-swappable hard drives. Each of these
drives is able to operate at about 30 MB/sec during operation. RAID-1 is implemented
on this drive array to provide a redundant configuration for the non-volatile storage. In
order to operate the drives after a power failure occurs, the RamSan-210 contains dual
redundant batteries. When fully functional and fully charged, the batteries are able to
provide about one hour of operation.
The management control port (MCP) monitors the internal disks and batteries for a
failure condition. In such an event, the management card will notify the operator of an
error through the front panel display and over the Ethernet.
The RamSan-210 operates in mirrored write mode. All data written to the RamSan-210
system memory is also automatically mirrored to the internal disk drives. An internal
cache is used to allow for write bursts to occur without incurring a delay for each write.
Since all write operations are synchronous in this mode, there is no need to copy data
from memory to disk when a power failure occurs. The system simply waits a user
selectable amount of time (default of 5 minutes) before the RamSan-210 is powered off.
While writes are made to both disks and memory, all reads are done directly from
memory. Therefore, the RamSan-210 is an excellent solution for applications that are
- 3 -
read intensive. Statistically, most applications have 80% reads and 20% writes. For
systems that are write intensive, please contact Texas Memory Systems to discuss
configuration alternatives.
The RamSan-210 with two FC32 Fibre Channel controllers should be able to provide
very close to 400MB/second of read performance.
The system will automatically conduct all reads and writes from the disk drives in the
event of a main memory failure (this type of failure is not expected). This fault tolerant
approach is designed into the system in order to provide the ultimate in data availability.
- 4 -
Chapter 2 – Installation
2.1 Electro-Static Discharge Warning
Important:
Please take full E.S.D. precautions if it is necessary at any time to come into contact with
any circuit boards, components or connectors. The components used in the RamSan-210
and its interfaces can be damaged by electrostatic discharge.
2.2 Battery Warning
The internal batteries in the RamSan-210 are charged with enough voltage to power a
fully loaded system for approximately one hour. However, the batteries may not be fully
charged when you install your system. Therefore, be sure your batteries are fully charged
before you use the system where there is risk of power failure.
2.3 System Inspection
The RamSan-210 should be shipped complete with a packing list. Make sure you have
received all of the components listed.
1. Examine the external chassis for any damage that might have occurred during
shipping.
2. Make sure that both power supplies are locked securely in place and that both
backup drives have not come loose.
3. Inspect the interface plate for any screws that might have loosen during shipping.
4. Inspect both the front and rear fans to make sure they are locked in place.
5. Inspect the front panel screen for damage.
6. Report any meaningful damage to Texas Memory Systems.
Figure 1 shows an overhead view of the layout of the RAM-SAN system components.
- 5 -
Figure 1 RamSan-210 Layout
- 6 -
2.4 Rack Mounting
The RamSan-210 is a 2U rack-mountable system. The system is shipped with the slides
and equipment needed to install it into a standard 19” rack.
2.5 Connecting the Fibre Channel Ports
After you have inspected the system and properly mounted it, connect the Fibre Channel
ports on the RamSan-210 to either your server or to a Fibre Channel switch. See for a
list of TMS approved SAN hardware.
Controller 1
Controller 2
Figure 2-2 RamSan-210 Interface Plate
Your system will be equipped with either one or two FC32 Fibre Channel controllers.
Figure 2- shows the port layout for the RamSan-210. Each controller has two Fibre
Channel ports A and B, on the left and right respectfully. These port numbers have no
correlation to the port identifiers assigned during port login. They are only used in the
management utilities for identification and LUN assignments. The interface plate also
has a DB-9 RS-232 serial connection and an RJ-45 Ethernet port. These ports are used
for local and remote management of the system. The FC32 ports on the system are
capable of connecting to point-to-point, arbitrated loop, and switched fabric topologies.
2.6 Connecting the Power Supplies
The RamSan-210 is equipped with dual redundant hot-swappable power supplies that
operate on 110/220 VAC line power. Using the provided AC power cords, connect both
power supplies to a source of power.
For normal system operation make sure both power supplies are connected to an external
power source. Since the power supplies are redundant, you may remove line power from
- 7 -
one without any interruption in Fibre Channel service. However, if external power is
completely lost, all Fibre Channel ports will go into a standby mode after a short user-
defined timeout period because the system will power off.
Warning:
Do not remove both power supplies from the system at the same time. This will cause
system failure since the internal batteries require that at least 1 power supply be present
in the system at all times. If both supplies are physically removed from the chassis,
possible data loss may occur.
“On” switch
Low Voltage
Battery
Figure 2-3 RamSan-210 Power Supply Modules
The following buttons and indicators are on the power supply:
·
The top button provides a means to activate the power supplies (turn them on)
after a user-initiated system shutdown. When a user initiates a shutdown of the
system, the power supplies are typically still connected. Therefore, the system
cannot use the presence or absence of AC to know whether to operate. In order
for the power to come on after a user initiated shut down, the top button must be
pressed on either of the power supplies. If power is restored after a power failure
or a power cord is reinserted, the system will automatically power on.
Low Voltage indicator light. The top indicator light shows when the power
supply is operating below the voltage necessary to power the entire system. Low
voltage indications are a sign that the power supply needs to be monitored and
possibly replaced.
·
·
Battery Operation indicator light. The bottom indicator light shows when the
system is operating from battery power. The system should only operate from
battery power when external AC power has failed.
Warning:
The power supply modules maintain high voltage levels during normal operation. To
prevent the risk of electrical shock, remove the power cord and wait 15 seconds before
removing a power supply module.
- 8 -
2.7 Turning on the System
The RamSan-210 will automatically power on when power is connected to the system.
The only time the system will not automatically power on is when a user has initiated a
Manual Shutdown of the system. In the event this has happened, it is necessary to press
the top button on either power supply. Please see 2.6 Connecting the Power Supplies.
2.8 System Initialization
The front panel display shows the current state of the boot process. Once the power is
connected, the system will turn on automatically and the front panel will begin the power
on sequence. The following will happen automatically (this boot sequence can also be
monitored externally through the serial port or Ethernet port):
1. After approximately seven seconds, the RamSan-210 will power-up.
2. You should see “Texas Memory
Systems” appear on the front panel, as
well as “RamSan-210”. Soon after
that you will see “Booting” and
“Initializing RamSan”.
3. After the firmware has finished booting, the front panel display will indicate
“Bringing Disks Online”. The system disks take approximately 10
seconds each to spin-up.
4. The front panel will indicate
“Restoring” and show a progress bar
and give an estimated time till
completion. Administrators may use this
to determine how much time before the
system is on-line. This information is
also available through the telnet remote
monitoring software in the status
command. This process will take
approximately 2 minutes 15 seconds for every 4 gigabytes of memory in the
system.
5. Once the system has restored data, the system will display “Status Good” and
show the performance bars for each Fibre Channel port.
The system is now ready for normal operation.
Please see Chapter 7 – Troubleshooting for possible error conditions during start-up.
Please see Chapter 3 – Using the Front Panel for more information on configuring the
Ethernet and monitoring system health.
- 9 -
Chapter 3 – Using the Front Panel
3.1 Overview
The front panel for the RamSan-210 allows you to inspect the state of the system, change
the method of IP address assignment, and shutdown the system. Four buttons located to
the left of the panel are used to make selections. Figure 4.1 is a picture of the front of the
system.
Figure 3-2 RamSan-210 Front Panel
The buttons on the front panel serve the following functions:
·
Menu. The Menu button has two functions:
o Function 1: On any of the status or performance displays, pressing the
“Menu” button will launch the RamSan-210 Main Menu.
o Function 2: Escape function. Pressing “Menu” once the menu is open
returns the user to the prior screen.
·
·
·
Select. If “Select” is pressed when a menu item is on the screen, the system will
either: execute that menu option or proceed to the next layer in the menu. This
button is disabled if the menu is not selected.
••. The “••” button scrolls up through the menu. The “••” is also used cancel
certain commands, as indicated on the display. This button is disabled if the
menu is not selected.
¯¯. The “¯¯” button scrolls down through the menu. The “¯¯” is also used confirm
certain commands, as indicated on the display. This button is disabled if the
menu is not selected.
- 10 -
3.2 Menu System Layout
The front panel menu system is as follows:
RS-210 Main Menu
· Ethernet Setup
§ Set IP Config
§ Static
§ IP
§ Subnet Mask
§ Gateway
§ DHCP
§ BOOTP
§ RARP
§ None
§ No Change (Exit)
§ Restart Network
§ Show Current Config
§ Exit Menu
· Manual Shutdown
§ Power off System?
· Exit Menu
3.3 Ethernet Setup
The RamSan-210 uses both a serial port and an Ethernet port to allow you to monitor and
configure the system. To access the system’s Ethernet port, the RamSan must be
assigned an IP address, subnet mask, and possibly a gateway. The IP address may be
assigned in one of five ways: Static IP, DHCP, BOOTP, RARP, or No Ethernet.
To setup the Ethernet, use the arrow buttons to cycle through the top-level menu options
until “Ethernet Setup” is showing on the display. Use the “Select” button to
choose this option and continue with the configuration. You may now use the arrow
buttons to scroll through the following menu options: “Set IP Config”, “Restart
Network”, “Show Current Config”, and “Exit Menu”. “Restart
Network” will shutdown and restart the Ethernet port using the current IP assignment
configuration. Selecting “Show Current Config” will display a list of the current
IP configuration, hostname, IP address, subnet mask, gateway address (if applicable), and
hardware Ethernet address. Use the arrow buttons to scroll up and down through the list.
Pressing the “Menu” button will return to the previous menu, and pressing the “Select”
button will exit the menu system. To continue setting up the Ethernet configuration,
select “Set IP Config”.
- 11 -
After selecting “Set IP Config”, you may use the arrow buttons to cycle though
“Static IP”, “DHCP”, “BOOTP”, “RARP”, “None”, and “No Change”. Talk to
your system administrator for the proper IP assignment type. Use the “Select” button to
select the desired method of IP assignment. If you did not choose “Static IP” you
are asked to confirm the selection with the “¯¯” button.
If you are setting up the RamSan-210 with a static IP, you need to have the Ethernet IP,
subnet mask, and a gateway address if you need to access the device from a different
network. After you have chosen “Static IP”, “Ethernet IP” replaces the top line
of the display, and you will be prompted to enter an IP. The “••” or “¯¯” buttons cycle
through the numbers “0” through “9”. To select the value, use the “Select” button. The
input prompt will move to the next character position. To back up a space, press the “••
”
and “¯¯” button simultaneously. You can press the “Menu” button at any time to cancel
the Static IP assignment. Repeat this procedure until the 4-byte address has been entered.
After you have finished entering the IP, the top line of the front panel will change to
“Subnet Mask”. Using the same procedure as entering the IP address, enter the subnet
mask. The final value you must enter is the “Gateway Address”. If the RamSan-210
is on a private network and this value is not needed, enter the value “0.0.0.0” to tell
the RamSan-210 to ignore this entry. After entering all three values, you will be
prompted to confirm the command with the “¯¯” button.
After confirming the new IP assignment mode, the display will indicate “Shutting
Down Network…” followed by a success or failure message. The display will then
indicate “Saving IP Config…” followed by a success or failure message. Next, the
RamSan-210 will attempt to start the network with the new settings, indicated on the
front panel display with “Restarting Network…”. Upon success, the new IP
address is displayed on the front panel for 15 seconds or until any button is pressed. If
the network fails to start, check the Ethernet connection and contact your system
administrator. If the IP configuration was successfully saved, you may simply select the
“Restart Network” option from the “Ethernet Setup” menu instead of re-
selecting the same IP configuration.
For any questions regarding IP assignment values, please consult with your network
administrator.
3.4 Manual Shutdown
The RamSan-210 may be shut down from the front panel. This procedure will safely
synchronize all data in RAM to the internal disk drive storage.
To shut down the system using the front panel, use the arrow buttons to cycle through the
top-level menu to select “Manual Shutdown”. Use the “Select” button to select this
menu item. You will be prompted to confirm that you wish to “Power Off System”.
To cancel the shutdown, use the “••” button again to return to the main menu. To proceed
with the shutdown, use the “¯¯” button to confirm the system power off. The front panel
- 12 -
display will now indicate that the system is powering off. This will typically take
between 5 and 15 seconds to complete.
As a reminder, in order to turn the RamSan-210 back on after a manual shutdown it is
necessary to press the top button on either power supply.
3.5 System Monitoring
When the menu on the front panel is not in use, it is possible to monitor various aspects
of the system. The following information is presented:
·
Fibre Channel port bandwidth. The front panel displays the Read and Write
performance of each Fibre Channel port. As seen in the picture, the indicator
lights correspond to the actual location of the ports on the RamSan-210. The top
indicators are for the top Fibre Channel interface board. The bottom indicators
are for the bottom Fibre Channel interface board. The left and right indicators
map to the left and right sides of the interface boards when you look at them from
behind. For each channel, the top half of the graph represents read megabytes per
second in 10 megabyte per second increments. The bottom half represents write
bandwidth.
·
·
Restore/Backup Progress. During any backup or restore, the front panel will
display the operation progress and estimated time remaining until completion.
Status. The following status levels are possible:
o “Good”. This is normal
operation.
o “*WARN*”. This indicates that a
System Warning has been
detected. Possible warnings
include:
– Front or rear fan trays
removed
– Power supply removed
– AC Lost at one or both
power supplies
– One or both batteries have been removed
– Temperature warning
– One or both disks removed
- 13 -
o “*FAIL*”. This indicated that a System Failure has been detected.
Possible failures include:
– Front or rear fan trays have a failed fan
– Power supply failed
– One or both batteries have failed
– System overheated
– One or both disks have failed
In the case of either System Warnings or Failures, the front panel display will
alternate between displaying status information and Warning/Failure messages
every 10 seconds.
- 14 -
Chapter 4 The Management Control Port (MCP)
4.1 Connecting to the MCP
The management port on the RamSan-210 allows you to manage, configure, and monitor
system behavior. This includes obtaining status information about internal hardware,
configuring the LUNs, and obtaining data rates of the system.
You may connect to the management port using either a DB-9 serial cable or an RJ-45
Ethernet cable.
4.1.1 RS232 Serial Port
To connect to the serial port use the DB-9 non-null serial cable supplied with the
system. You need to set your terminal program to 9600 baud, 8 data bits, no
parity, and 1 stop bit.
4.1.2 Ethernet
In order to use the Ethernet port, you must first configure the IP address for the
RAM-SAN. You may configure the IP using the front panel display or from the
serial port. For a complete description for configuring the Ethernet using the front
panel, please refer to Section 3.3 of this manual. If you are configuring the
Ethernet using the serial port refer to Section 4.5.5 of this manual.
4.2 Connecting using a terminal program
To connect to the RamSan-210 using a serial port connection, you must use a dumb
terminal or a terminal emulation program such as Windows™ HyperTerminal. Your
baud rate should be set to 9600 with 8 data bits, 1 stop bit, no parity, and no flow control.
4.3 Connecting using telnet
Once the Ethernet port on the RamSan-210 has been configured using either the front
panel or the serial port, you may remotely monitor the system using a telnet session.
Your terminal settings should be set to VT100 mode.
4.4 Logging into the system
The RamSan-210 has two login accounts, “root” and “user”. Default passwords for both
accounts have been left blank.
- 15 -
4.5 MCP Commands
4.5.1
EXIT
The exit command is used to close a monitor session. The “QUIT” command also
performs the same action.
4.5.2
HELP
The “HELP” command provides a brief online description of each command that is
available. Commands that require parameters are listed with the “<parameters>” as
options. Commands with optional parameters are listed with the “[parameters]” as
options.
4.5.3
CONFIGSYS
The system configuration utility allows you to configure various system dependant
options. Currently, the only option available is the amount of time the management
controller waits after power loss before it initiates an automatic shutdown.
** Ethernet configuration utility **
1. Set time to wait after losing power before system shutdown
Q. Exit
Select:
By selecting option “1” you may set the power down delay to be between 1 and 15
minutes. The default value is 5 minutes.
4.5.4
FIRMWARE
The “FIRMWARE” command shows the firmware revision levels for various components
in the RamSan-210. This command is mainly for internal use for tracking firmware
revision levels.
4.5.5
IPCONFIG
The Ethernet monitor port is configured using the “IPCONFIG” command. The
RamSan-210 supports IP assignment through DHCP, BOOTP, RARP, or setting a static
IP. This command may only be used from the serial port since it involves changing the
network settings. Here is a demonstration of the command:
ram-san> ipconfig
** Ethernet configuration utility **
IP assignment mode = RARP
Hostname
= ram-san
Ethernet MAC Address = 00:20:c2:00:08:05
- 16 -
IP Address
Netmask
= 192.94.231.206
= 255.255.255.0
Select option:
1. Change IP assignment mode
2. Change hostname
S. Save changes, restart the network, and exit
Q. Cancel (No changes)
Enter selection:
To change the IP assignment mode enter “1”. This will present the following screen:
** Ethernet configuration utility **
Current IP assignment: RARP
Select option:
1. Select static
2. Select DHCP
3. Select BOOTP
4. Select RARP
5. Disable Ethernet
Enter selection:
To set the RamSan-210 up with a static IP, type “1” and press enter. You will then be
prompted for IP address, subnet mask, and gateway address. If your network does not
use a gateway, use the gateway address of 0.0.0.0 to disable this feature. The output will
look like:
Ethernet IP address [255.255.255.255]: 192.168.0.100
Ethernet subnet mask [255.255.255.0]: 255.255.255.0
Ethernet gateway [0.0.0.0]: <enter>
All other options set the assignment mode and return you to the main menu immediately.
You may cancel from this menu by selecting the same assignment mode as the current IP
assignment value.
The option “2. Change hostname” from the main menu allows you to change the
hostname associated with the RamSan-210.
If you are configuring your system with a static IP address, you will be presented with
options 3, 4, and 5 on the main menu. These options allow you to change the IP, subnet
and gateway values for the Ethernet.
- 17 -
To exit the IP configuration utility, select “S” to save the changes you have made. The
network will be reconfigured to use the new Ethernet settings you have chosen. To
discard any changes you have made, use the “Q” option.
4.5.6
LUNCONFIG
This command is a memory-partitioning tool that allows the administrator to configure
system memory into LUNs that may be assigned to specific Fibre Channel ports in the
RamSan-210. The LUNs may also be assigned access lists that mask the visibility to
specific servers.
4.5.7
MANAGE
The manage command allows the user to enable or disable network management
methods. The Manage command also supports configuration of SNMP. When option
“1” is selected, it toggles the current value. For example, if the current value is disabled,
then selecting “1” will change the value to “enabled”.
The following screen displays show the output from the SNMP commands:
ram-san> manage
** Management configuration utility **
Telnet = enabled
SNMP = disabled
Select option:
1. Disable telnet management
2. Configure SNMP
S: Save changes and exit
Q: Discard changes and exit
Enter selection:
4.5.8
PASSWORD
Since it is possible to access the RamSan-210 remotely through the management port, a
password feature has been included for system security. By default, the root and user
passwords are left blank. In order to change the password, the current password must be
entered first. However, on the console, the password may be overridden without
requiring the current password.
- 18 -
The password feature is automatically bypassed when logging in on the serial console.
This feature allows a system administrator access to the RamSan-210 if the password is
forgotten or lost.
4.5.9
PERFORMANCE
The “PERFORMANCE” command may be used to view the bandwidth of each port. The
monitor shows the average bandwidth of each port over a period of one second. This
performance view shows only DMA activity and does not show other Fibre Channel
activity. To stop the output from this command, press “Q”.
ram-san> perf
Press ‘s’ to toggle scroll mode, ‘q’ to quit.
-- Controller 1 --
I/O B: Band
-- Controller 2 --
I/O B: Band
A: Band
93.2
I/O A: Band
I/O
350
337
345
356
97.2
97.1
370
369
96.6
97.0
359
367
95.2
92.8
96.5
4.5.10 PORTCONFIG
The “PORTCONFIG” command is used to configure the Fibre Channel controllers. After
the “PORTCONFIG” command is entered, the current configuration is listed and the
available options are listed.
4.5.11 POWEROFF
The “POWEROFF” command is equivalent to a front panel “Manual Shutdown”.
This will power off the system. Before powering off the system, all writes will be
completed. Note: To resume operation, it is necessary to press the top button on either
power supply.
4.5.12 REBOOT
The Reboot command allows a system administrator to reboot the management
controller. This command should only be needed under rare circumstances.
4.5.13 RESET
The “RESET” command allows the administrator to reset individual ports on the
RamSan-210. This command should only be needed under rare circumstances since the
Fibre Channel ports handle the appropriate reset protocol. To issue this command, a port
number is specified as a parameter to the command.
- 19 -
4.5.14 STATUS
The “STATUS” command provides a variety of configuration details for the MCP and the
Fibre Channel controllers.
ram-san> status
Texas Memory Systems, Inc.
RamSan-210 Monitor
Software Version: 1.0.1
Ethernet address: 00:20:c2:00:08:05
Ethernet IP:
Capacity:
192.94.231.206
4096 Megabytes
System Status:System Idle
FC32 Controller 1 -- Not installed
FC32 Controller 2 - Firmware version: 0.9d
Channel A: 10:02:00:20:c2:00:08:03
Channel B: 11:02:00:20:c2:00:08:03
offline
offline
- 20 -
Chapter 5– Hot Swap Components
One of the main features of the RamSan-210 is the ability to hot swap many of the
system components. The power supplies, fans and disk drives can all be hot swapped;
meaning that these components can be removed and replacement components reinserted
while the system is running.
5.1 Hot Swapping Power Supplies
The RamSan-210 includes two power supplies. The system only requires one
functioning power supply to run. Texas Memory Systems has taken special care to
enclose the RamSan-210 power supplies in a protective case in order to minimize the
electrical risks for users. It is critical, however, that users follow the following steps
when removing and replacing the power supplies:
Warning:
The power supply modules maintain high voltage levels during normal operation. To
prevent the risk of electrical shock, remove the power cord and wait 15 seconds before
removing a power supply module.
·
·
·
Disconnect the power cord from the power supply that needs to be replaced.
Wait 15 seconds.
Remove the power supply from the RamSan-210 chassis by pressing the release
switch and pulling squarely on the power supply handle. DO NOT REACH
INSIDE THE PROTECTIVE ENCLOSURE AFTER REMOVING THE
POWER SUPPLY.
·
·
Insert the replacement power supply in the RamSan-210 chassis. Make sure to
insert the power supply squarely and press firmly until the power supply is fully
inserted into the system.
The new power supply will begin to operate within a couple of seconds.
Important:
The power supply modules are linked to the batteries. If a power supply module is
removed, the battery that feeds it will not provide power to the system. In other words,
the batteries only work when attached to a functional power supply. Never
simultaneously remove both power supplies while the system is running. The system will
cease operation.
Important:
Failed power supplies should be replaced as soon as possible.
- 21 -
5.2 Hot Swapping Disk Drives
The RamSan-210 includes two mirrored hard disk drives. The system can operate with
two disks operational, one disk operational or no disks operational. Normal operation
mirrors writes to both disk drives.
If a single disk drive fails, the system will continue to write to the available disk drive.
At this point, it is desirable to replace the malfunctioning disk with a new disk drive.
Once inserted, the system will rebuild the disk by executing a disk-to-disk copy. Overall
system write performance will be degraded during the restore, but read operations will
continue uninterrupted.
Important:
Do not remove either disk drive during a disk-to-disk copy. Removing either disk drive
will destroy data on both disks. This will then require both drives to be removed and
replaced for a memory to disk resynchronization.
If both disks fail, the system will perform all operations from memory. This is a volatile
state. When functional disks are inserted, the system takes the Fibre Channel interfaces
off-line and executes a memory to disk copy.
The following steps should be used to replace bad disk drives:
1. Verify that a disk-to-disk copy is not in progress. If it is in progress, then wait for
the disk-to-disk copy to complete.
2. Slide the disk eject latch to the right.
3. Remove the disk by pulling squarely on the handle.
4. Insert new disk squarely into the available slot. Make sure the disk drive is
completely inserted into the system and flush with the chassis.
Important:
Failed disk drives should be replaced as soon as possible. You should only use TMS
factory certified disk drives for replacement.
Important:
It is not advised to remove disks that are functional. The action should be perfectly safe,
unless a disk-to-disk copy is in progress, but will impact system performance as the new
disk drive is rebuilt from the mirror.
5.3 Hot Swapping Fans
The fans in the RamSan-210 can be removed and replaced during system operation.
There are two blocks of three fans each. The blocks are accessed from different
locations. The rear fan block is easily accessed from the rear of the chassis. Removing
the front panel from the RamSan-210 provides access the front fan block.
- 22 -
The following steps should be performed to hot swap a fan block:
1. Slide the latch on the fans to the left and simultaneously pull firmly on the fan
handle. The unit will slide out from the chassis. Use caution to avoid hitting the
spinning fan blades once removed.
2. Firmly insert the new fan block into the RamSan-210 chassis. The fans will begin
immediate operation once inserted into the chassis.
Important:
Failed fans should be replaced as soon as possible.
- 23 -
Chapter 6 – Batteries
The RamSan-210 is equipped with two redundant one-hour Lithium Ion batteries. The
batteries are designed to support the RamSan’s operational modes. Specifically, if
external power to the RamSan-210 is lost, the system will continue to function running
on the internal batteries.
The batteries in the RamSan-210 are linked to the power supply units. In the event a
power supply is removed or broken its attached battery will not work. The batteries are
designed to provide power for the system in the event external power is lost, not in case
both power supplies fail.
The RamSan-210 can be configured to run on battery power for up to fifteen minutes
after external power is lost. The system default is to stay on for five minutes after power
fails. Because the RamSan-210 uses a mirrored writes mode, the system only has to stay
on for one minute in order to clear the disk buffer and disk cache. The amount of time
that the RamSan-210 stays on line can be user defined from one to fifteen minutes. If
power is restored within this time period, the system will stay online.
- 24 -
Chapter 7 – Troubleshooting
After the system runs short self-tests on each internal component, the hardware initiates
synchronization between disk and memory. To obtain further information about the
failing location, the management port must be used.
Contact Information:
Texas Memory System, Inc.
11200 Westheimer Suite #1000
Houston, Texas 77042
713-266-3200
- 25 -
Chapter 8 – Specifications
8.1 Physical Characteristics
Rack Mount Size:
Weight:
2U (3.5”) x 25” deep
50 lbs.
Voltage:
Ventilation:
110 or 220 VAC
Side to side airflow
Rear exhaust for power supplies
8.2 Operating Environment
Temperature:
32-85 °F (0-30 °C)
Max relative humidity:
(non-condensing)
Max heat dissipation:
Power consumption:
80%
512 Btu/hr (150 W)
100-150 W
8.3 Non-operating Environment
Temperature:
Relative Humidity:
32-150 °F (0-65 °C)
10-90%
(non-condensing)
8.4 Warranty
1 year FOB
Texas Memory Systems, Inc.
Houston, Texas
- 26 -
Appendix A – RamSan-210 Replacement Parts
Figure B-1 MCP31 Management Control Processor
Figure B-2 FC32 Dual channel 1 gigabit Fibre Channel controller
- 27 -
Figure B-3 PWR21 Power Supply Module
Figure B-4 FAN21 Hot swappable fan tray
- 28 -
Figure B-5 MEMG41 4 Gigabyte memory blade
Figure B-6 TDD21 18 gigabyte replacement hard drive
- 29 -
|
Toshiba Protege PT311U0DH02V User Manual
Toastmaster ME8TPB User Manual
Tascam cdrw 402 User Manual
Sungale CA700VCR User Manual
Sony Ericsson Z780i User Manual
Sony Ericsson S80 User Manual
Sony 1261 4178 User Manual
Silvercrest KH 2289 User Manual
Samsung Cell Phone SGH S275 User Manual
Philips FM01SW80 User Manual