T1 Remote Module Installation
Link Wireless Telephone System
Link 3000 MCU
Part Number: 72-0059-06
Issue E
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Note concerning the Master Control Unit:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Note concerning shielded cable:
SpectraLink recommends the use of shielded cable for all external signal connections in order to maintain
FCC Part 15 emissions requirements.
Note concerning the Wireless Telephone and Base Stations:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
WARNING Changes or modifications to this equipment not approved by SpectraLink Corporation may
cause this equipment to not comply with part 15 of the FCC rules and void the user’s authority to operate
this equipment.
WARNING SpectraLink products contain no user-serviceable parts inside. Refer servicing to qualified
service personnel.
Part Number: 72-0059-06-E.doc
Page 3
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
UL Information
This symbol on the nameplate means the product is listed by Underwriter’s
Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety
standards against X-radiation, fire, casualty, and electrical hazards.
The following are statements required for UL certification, related to safety procedures
that must be adhered to during installation.
Follow these general precautions while installing telephone equipment:
• Never install telephone wiring during a lightning storm.
• Never install telephone jacks in wet locations unless the jack is specifically designed
for wet locations.
• Never touch uninsulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
• Use caution when installing or modifying telephone lines.
When installing Base Stations outside or in buildings other than the one containing the
System Controller, take the following precaution:
If wiring for a Base Station exits a building—whether to reach an outdoor Base Station
location or to reach a Base Station in another building—the wiring must be protected at
both ends by a Quick Clip Fuse from Illinois Tool Works, Linx Division, model number
SCP-2X2. The Quick Clip Fuse replaces the bridging clips on the 66 blocks for all four
connections to the non-internal Base Station.
Part Number: 72-0059-06-E.doc
Page 4
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
FCC Information
The Master Control Unit Complies with Part 68, FCC Rules
FCC Registration Numbers:
Link 3000: IYGUSA-7385Q-PX-T
Ringer Equivalence:
Link 3000: 0.3B
SpectraLink Corporation
Link 3000
Made in the USA
This equipment complies with Part 68 of the FCC Rules. On the back of this equipment is a label that
contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN)
for this equipment. If requested, this information must be given to the telephone company.
This equipment uses RJ-21 connectors.
The REN is useful to determine the quantity of devices you may connect to your telephone line and still
have all of those devices ring when your number is called. In most, but not all, areas, the sum of the RENs
of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices
you may connect to your line, as determined by the REN, you should contact your local telephone company
to determine the maximum REN for your calling area.
If your telephone equipment causes harm to the telephone network, the telephone service may discontinue
your service temporarily. If possible, they will notify you in advance. But if advance notice isn’t practical,
you will be notified as soon as possible. You will be informed of your right to file a complaint with the
FCC.
Your telephone company may make changes in its facilities, equipment, operations or procedures that
could affect the proper functioning of your equipment. If they do, you will be notified in advance to give
you an opportunity to maintain uninterrupted telephone service.
If you experience trouble with this telephone equipment, please contact SpectraLink Corporation for
information on obtaining service or repairs.
SpectraLink Corporation
5755 Central Avenue
Boulder, CO 80301
303-440-5330
The telephone company may ask that you disconnect this equipment from the network until the problem
has been corrected or until you are sure that the equipment is not malfunctioning. There are no user
serviceable parts in this equipment.
This equipment may not be used on coin service provided by the telephone company. Connection to party
lines is subject to state tariffs.
Part Number: 72-0059-06-E.doc
Page 5
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Industry Canada (IC) Notice
Notice:
The Industry Canada (IC) label identifies certified equipment. This certification means that the
equipment meets telecommunications network protective, operational, and safety requirements as
prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The
department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the
facilities of the local telecommunications company. The equipment must also be installed using an
acceptable method of connection. The customer should be aware that compliance with the above
conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the
supplier. Any repairs or alterations made by a user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power
utility, telephone lines and internal metallic water pipe system, if present, are connected together.
This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
Notice: The Ringer Equivalence Number (REN) assigned to each terminal device provides as
indication of the maximum number of terminals allowed to be connected to a telephone interface.
The termination of an interface may consist of any combination of devices.
REN
0.3B
Approval Numbers:
Link 3000: 2128-9508 A
Warranty and Repair Service Center:
SpectraLink Corporation
5755 Central Avenue
Boulder, CO 80301
303-440-5330
DOC Spread Spectrum certification
Base Station
Cert. No.
Cert. No.
2128-K1373
2128-K1374
Wireless Telephone
Part Number: 72-0059-06-E.doc
Page 6
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Table of Contents
Part Number: 72-0059-06-E.doc
Page 7
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
1. About This Document
This document explains installation of the SpectraLink Link Wireless Telephone System
(Link WTS, MCS300) Remote T1 Module. The installation process connects the Link
3000 MCU Primary Shelf in one location with an Expansion Shelf in a remote location,
via T1 facilities.
1.1 Contacting SpectraLink
SpectraLink wants every customer to have a successful installation. Please refer questions
to our Customer Support Hotline at (800) 775-5330. The Hotline is open Monday
through Friday, 7:00 AM to 6:00 PM Mountain Time.
1.2 Icons Used in this Document
This manual uses the following icons and conventions.
Caution! Follow these instructions carefully to avoid danger.
Note these instructions carefully.
ꢀ
NORM
This typeface indicates a key, label, or button.
Part Number: 72-0059-06-E.doc
Page 8
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
1.3 Remote Installation Overview
Networking the Link WTS allows installation of expansion shelves at remote locations.
T1 circuits are used to provide the connection from the System Controller shelf to each
Remote Expansion shelf. As many as 19 expansion shelves may be supported by the
system, and up to 18 of these shelves may be installed in remote locations from the
System Controller shelf. The Link WTS (local site and remote site shelves) is
administered as a single system.
The following diagram shows an overview of a Link WTS with shelves at both a local
and remote site.
Location A - Local
Location B - Remote
CSU
CSU
CSU
CSU
T 1
T 1
1
2
3
4
5
6
7
8
9
10 11 12
1
2
3
4
5
6
7
8
9
10 11 12
Shelf 3 - Expansion Shelf
Shelf 1 - Primary Shelf
CSU
CSU
Intershelf Junction Panel
T 1
CSU
T 1
CSU
1
2
3
4
5
6
7
8
9
10 11 12
Shelf 4 - Expansion Shelf
1
2
3
4
5
6
7
8
9
10 11 12
Shelf 2 - Expansion Shelf
1
2
3
4
5
6
7
8
9
10 11 12
Shelf 20 - Expansion Shelf
Part Number: 72-0059-06-E.doc
Page 9
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
1.4 Remote Installation Steps (Overview)
Follow these steps to install the T1 Remote Module. Detailed instructions for each of
these steps are contained in this document and other relevant documents in the Link 3000
MCU System Documentation.
1. Prepare site and check components.
2. Install T1 Remote Module at the local site (location where the Primary Shelf is
located.)
3. Connect T1 Remote Module at the local site to the Intershelf Junction Panel and
T1 facilities.
4. Install Expansion Shelf at remote site.
5. Install T1 Remote Module, Shelf Controller, and Interface Modules at remote site.
Note that GPS timing may be required when remote and main shelves are within
600-800 feet of one another.
6. Connect T1 Remote Module at the remote site to the Shelf Controller and T1
Facilities.
7. Install any additional Expansion Shelves at remote site, and connect Expansion
Shelves at the site.
8. Connect RJ-21 cables for telephone lines and Base Stations to Interface Modules
at remote site.
9. Configure remote system and register Wireless Telephones.
Part Number: 72-0059-06-E.doc
Page 10
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
2. Site Preparation
The following steps must be completed before installing the system hardware. If the
steps are not already completed refer to each individual section for details.
1. At the local site, install and test Primary Shelf and Expansion Shelves. Refer to
Link WTS – Link 3000 MCU: Installation (72-0059-01) for information.
2. At the remote site:
2.1 Install a two pair cable to each Base Station as designated on the building
floorplans.
2.2 Terminate the Base Station wiring with RJ-45 crimp-on plugs at the
designated Base Station locations.
2.3 Terminate the Base Station wire at the appropriate cross-connect demarc
blocks.
2.4 Terminate the analog or digital phone extensions from the phone system at
the appropriate cross-connect demarc block, and label the block.
2.1 Required Materials Provided by Customer
ꢁRack - the shelves are designed to fit into a 19 inch mounting rack. Each shelf
measures 15” high by 19” wide by 9” deep, and weighs approximately 35 pounds
fully loaded. See Prepare Location for Shelves, in the Link WTS – Link 3000 MCU:
Installation document.
ꢁBackboard space – as an alternative to rack mounting, the shelves can be wall
mounted to ¾” plywood securely screwed to a wall.
ꢁScrews – required to mount the shelves to the wall, or to secure it in the rack. For
wall mount, six #10-5/8” panhead wood screws (or similar device) are required. For
rack mount, screws required are determined by the rack requirements; typically 10-32
or 1/4-20.
ꢁRJ-45 Cable - for network clocked T1 facilities, an RJ-45 cable is required to
connect the designated Master Clock T1 Module to the Intershelf Junction Panel.
Part Number: 72-0059-06-E.doc
Page 11
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
2.2 T1 Configuration Requirements
T1 circuits will connect expansion shelves directly to the System Controller shelf via the
SpectraLink provided Intershelf Junction Panel. The Intershelf Junction Panel is always
co-located with the system controller shelf.
The following configuration requirements apply to the T1 lines connecting the Link 3000
MCU local and remote shelves.
ꢁAll T1 circuits for networking the Link WTS must be Extended Superframe Format
(ESF).
ꢁT1 circuits must be a full T1 (not fractional).
ꢁT1 circuits must be 64Kbps (not 56Kbps) per channel.
ꢁLine coding for the T1 circuits must be Bipolar 8-bit Zero Substitution (B8ZS).
ꢁT1 circuits should be terminated as close to the Link 3000 MCU shelves as possible,
at both the System Controller site and the Expansion Controller site(s).
ꢁOne or two T1 circuits are required per remote Link 3000 MCU Expansion Shelf.
• One T1 circuit is required for the first five Interface Module cards in a Remote
Expansion shelf.
• Two T1 circuits are required for 6 or more Interface Module cards installed in the
remote expansion shelf. Note that 1 - 10 Interface Module cards may be installed
in any expansion shelf.
ꢁThe T1 circuit must be activated and verified to be in proper working order at least
one week in advance of the networked Link WTS scheduled installation.
Channel Service Unit (CSU)
A Channel Service Unit (CSU) must be installed at each end of the T1 circuit.
• The ADC Kentrox T-SERV II or other comparable CSU models are satisfactory.
• From the CSU, the T1 circuit must be provided to the SpectraLink system on an
RJ-48C modular connector.
• The CSU must have an independent power supply, per manufacturer
specifications.
Part Number: 72-0059-06-E.doc
Page 12
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
2.3 Check Components
The following items should be at the installation site.
ꢁLink 3000 MCU Expansion Shelves – (MCS300) – the number of shelves varies
depending on the size of the system.
ꢁGrounding Strap – (in the Link WTS Administration Kit, MKA320) – to protect
cards from electrostatic discharge.
ꢁExpansion Shelf Controller Card – (CSC300) - one card for each Expansion Shelf.
This card is installed in Slot 2.
ꢁT1 Remote Module– (CRC301) - one card for the remote site and one card for the
local site for EACH remote shelf.
ꢁCables – two 12 foot RJ-45 cables with each Expansion Shelf Controller (CSC300).
RJ-45 cable to connect multiple shelves (one for each shelf).
ꢁInterface Modules – the correct number and type of Interface Modules to connect
the Wireless Telephones and the Base Stations to the telphone system. Interface
Modules can support analog (CPA316), Universal digital (CPU316), Mitel
(CPM316), Executone (CPB316), Panasonic (CPP316), and select four-wire
(CPF316) interfaces.
Part Number: 72-0059-06-E.doc
Page 13
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
3. Install T1 Remote Module at Local Site
Before installing the hardware at the remote site, the Primary shelf at the local site must
have a T1 Remote Module (CRC301) installed. Install one Remote Module for each
remote shelf to be installed.
Slide the Remote Module into slot 1 or slot 3-12 of any shelf, until the card clicks into
place. Tighten the screws at the top and bottom of the card to secure it. The Remote
Module can go in any slot, in any shelf of the system, except slot 2.
Cards contain components that may be damaged by electrostatic discharge.
Before handling any of the cards, the installer must attach the grounding
strap (included in the Administration Kit) to his or her wrist, and attach the
other end of the strap to ground. Only handle the cards by their edges. Do
not touch connector contact areas, do not lift cards by any of the components,
and do not lay cards down on their component sides. When laying a card
down, place it component side up on top of the anti-static bag in which it was
shipped.
Connect Intershelf Junction Panel
Connect two RJ-45 cables from the System Controller ports in the T1 Remote Module to
the corresponding shelf ports on the Intershelf Junction Panel (JPI300). Be sure the RJ-
45 cable in Connector A on the Remote Module goes to the A connector on the JPI300,
and that Connector B goes to the B Connector.
The following diagram outlines the ports on the JPI.
SHELF 2-6
SHELF 7-11
SHELF 12-16
SHELF 17-20
A
B
A
B
A
B
A
B
2
7
12
17
3
8
13
18
4
5
6
9
14
15
16
19
20
10
11
AUX
RJ-45 Connectors to
Shelf Controllers
Part Number: 72-0059-06-E.doc
Page 14
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Network Clocked T1 Facilities
If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as
the Master Clock Source. Connect the Sync IN port on this T1 Remote Module to AUX
port A on the Intershelf Junction Panel. Note, this shelf must also be designated as the
Master Clock in the system configuration.
Connect T1 Facilities
Connect the RJ48C jack from the CSU port at the local end to the DS1 A and DS1 B
ports on the T1 Remote Module. Port A controls slots 3-7 on the remote module at the
far end. Port B controls slots 8-12.
The following diagram shows the T1 Remote Module connections at the LOCAL site.
Part Number: 72-0059-06-E.doc
Page 15
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
CRC-301
TIMING
MASTER
IN
SYNC
OUT
To AUX Port on Intershelf
Junction Panel for Net Clocked T1
ALARM
1
2
3
4
5
A
SYSTEM
CONTROLLER
RJ45 to Intershelf Junction Panel
B
SC/A
EXPANSION
SHELF
CONTROLLER
SC/B
LOS
LIKOK
DS1 A
T1 connection Module 3-7
on remote
LOS
LIKOK
DS1 B
T1 connection Module 8-12
on remote
Part Number: 72-0059-06-E.doc
Page 16
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
4. Install System at Remote Site
4.1 Survey Site
Check the site to be sure pre-installation work has been completed correctly. This
includes:
• Location chosen for the shelves is adequate.
• Rack (if rack mounted) is properly secured or backboard (if wall mounted) is properly
prepared.
• Power is available.
• Wiring to Base Station locations has been pulled and correctly terminated.
• Phone lines for the Wireless Telephones are installed and properly terminated.
• Telephone system administrator is available to program the existing telephone
system.
4.2 Install Shelves
Rack Mount
To install shelves in the rack, slide the shelves into the rack and secure them to the rack
using eight screws, 1/4 inch minimum length.
Wall Mount
At this point in the installation process, there should be a backboard securely fastened to
the wall and mounting screws partially inserted into the backboard. See Link WTS – Link
3000 MCU: Installation for more information.
To attach the shelves to the wall:
1. Remove all cards from the shelf. Do not mount the shelf with cards installed.
Cards contain components that may be damaged by electrostatic discharge.
Before handling any of the cards, attach the grounding strap (included in the
Administration Kit) to your wrist, and attach the other end of the strap to
ground. Handle cards only by their edges. Do not touch connector contact
areas. Do not lift cards by any of the components. Do not lay cards down on
their component sides. When laying a card down, place it component side
up, on top of the anti-static bag in which it was shipped.
2. Position the MCS300 so that the six mounting screws are aligned with the six
keyhole openings in the back of the shelf.
3. Slide the shelf down onto the screws to lock the shelf into place. Check that all
six screws are properly locked.
4. Tighten all six screws fully.
Part Number: 72-0059-06-E.doc
Page 17
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Do not install cards until power is connected.
ꢀ
4.3 Connect Power to Shelves
SpectraLink recommends that a licensed electrician install the –48V DC power supply
and connect power to the shelves.
See Link WTS – Link 3000 MCU: Installation, Connect Power to Shelves, for more
information.
4.4 Install Cards
The shelf diagram below shows a fully loaded Expansion Shelf. Any type of Interface
Module can be installed in slots 3-12.
Cards contain components that may be damaged by electrostatic discharge.
Before handling any of the cards, the installer must attach the grounding
strap (included in the Administration Kit) to his or her wrist, and attach the
other end of the strap to ground. Only handle the cards by their edges. Do
not touch connector contact areas, do not lift cards by any of the components,
and do not lay cards down on their component sides. When laying a card
down, place it component side up on top of the anti-static bag in which it was
shipped.
Install T1 Remote Module
1. Slide the T1 Remote Module into Slot 1 of the Expansion Shelf, until the card
clicks into place. Tighten the screws at the top and bottom of the card to secure it.
Install Expansion Shelf Controllers (CSC300)
2. Slide the Expansion Shelf Controller Card into Slot 2 of each shelf (2-20), until
the card clicks into place. Tighten the screws at the top and bottom of the card to
secure it.
3. Slide the Interface Modules into Slots 3-12 of each shelf (2-20) until the card
clicks into place.
Install Interface Modules (CPx316)
4. Slide the first Interface Module into Slot 3 of the Primary Shelf, until the card
clicks into place. Tighten the screws at the top and bottom of the card to secure it.
5. Slide additional Interface Modules into their slots. Slots can be left empty if
desired.
The following diagram shows a sample fully loaded Remote Expansion Shelf.
Part Number: 72-0059-06-E.doc
Page 18
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Expansion Shelf
Controller Slot 2
T1 Remote
Module
Interface Modules
Slots 3-12
RS-232
CRC-301
DISABLE
NORMAL
DISABLE
NORMAL
DISABLE
NORMAL
DISABLE
DISABLE
NORMAL
DISABLE
NORMAL
DISABLE
DISABLE
NORMAL
DISABLE
NORMAL
DISABLE
NORMAL
TIMING
MASTER
NORMAL
NORMAL
SC/A (RJ45)
SC/B (RJ45)
IN
SYNC
OUT
CONN
B
CONN
B
CONN
B
CONN
B
CONN
B
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
A
SYSTEM
CONTROLLER
B
SC/A
EXPANSION
SHELF
CONTROLLER
CONN
A
CONN
A
CONN
A
CONN
A
CONN
A
CONN
A
CONN
A
CONN
A
CONN
A
CONN
A
SC/B
LOS
LNKOK
DS1
A
LOS
LNKOK
DS1
B
1
2
3
4
5
6
7
8
9
10 11 12
Fully Loaded Remote Expansion Shelf
4.5 Connect Cables to T1 Remote Module
Connect T1 Remote Module to Expansion Shelf Controller
1. Using an RJ-45 cable, connect the Expansion Shelf Controller Port SC/A in the
T1 Remote Module (slot 1) to the SC/A port on the Expansion Shelf Controller
(slot 2).
2. Using an RJ-45 cable, connect SC/B in the T1 Remote Module to SC/B in the
Expansion Shelf Controller.
Connect T1 Facilities
3. Connect the T1 (CSU) port to the DS1 A and DS1 B ports on the T1 Remote
Module. Port A controls slots 3-7. Port B controls slots 8-12.
4.6 Connect Multiple Remote Shelves
If the remote site consists of more than one remote shelf, the shelves must be connected
to each other.
Connect the IPC cable from the Sync OUT Port of the T1 Remote Module on the first
shelf to the Sync IN Port of the T1 Remote Module on the next shelf. Repeat until all
shelves are connected.
Note that the IN port of the first module is not used.
Part Number: 72-0059-06-E.doc
Page 19
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
The following diagram shows the T1 Remote Module connections at the REMOTE site.
CRC-301
TIMING
MASTER
IN
SYNC
From sync "Out" if
more than one remote shelf
OUT
To sync "In" if more
than one remote shelf
ALARM
1
2
3
4
5
A
B
SYSTEM
CONTROLLER
SC/A
EXPANSION
SHELF
CONTROLLER
RJ-45 to Expansion Shelf
SC/A and SC/B
SC/B
LOS
LIKOK
DS1 A
T1 connection to local
Module 3-7
LOS
LIKOK
DS1 B
T1 connection to local
Module 8-12
Part Number: 72-0059-06-E.doc
Page 20
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
4.7 Connect Demarc Block RJ-21 Cables to Interface
Modules
Connect the male RJ-21 connector from the appropriate demarcation block to the
designated RJ-21 connector (A or B) on each Interface Module. Secure the cables using
the keeper. Dress the cables by wire wrapping the cable at the rear of the shelf.
Part Number: 72-0059-06-E.doc
Page 21
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
5. Configure Remote System
Use the Operator’s Console to enter configuration information for the Remote Expansion
Shelves.
5.1 Configure Remote Shelf
1. From the Operator’s Console, select F1, Supervisor State Display.
2. Use the arrow keys to highlight the number of the Remote Shelf to be added (2-
20), and press Enter.
3. Select Remote Card Options.
4. Select Edit Remote Cabinet Configuration. The following screen displays.
5. Enter the configuration information for the remote shelf (cabinet). Use the right
arrow or mouse to display options. Use the arrow keys to highlight an option, and
press Enter to select the highlighted option.
T1 A State: select T1 On to turn on T1 A.
T1 B State: select T1 On to turn on T1 B.
Far Sync Source: Leave the default (None) or select External Port if the far
sync source is an external port.
Far Cluster Master: Leave the default (None) if there is only one Expansion
Shelf at the remote location. If there is more than one Expansion Shelf at the
remote location, select a Cabinet (2-20) as the master shelf for this location.
Net Clocked T1: Leave the default (No) if the T1 is not Net Clocked, select Yes
if it is.
Note - enter the name or location of the remote T1 module.
6. Select SAVE to save the information.
Part Number: 72-0059-06-E.doc
Page 22
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
5.2 Master Clock Configuration
If the T1 facilities are Network Clocked, one shelf must be designated as the Master
Clock Source.
1. From the Operator’s Console, select F8, Configuration Display and
Administration. The following screen displays.
2. Select Field 12. Master Clock Cabinet.
3. Enter the shelf number of the Master Clock shelf.
4. Select SAVE to save the information.
5.3 Test System
The system should now be tested to ensure that it is functioning correctly. See Test
System in the Link WTS – Link 3000 MCU: Installation manual for more information.
Part Number: 72-0059-06-E.doc
Page 23
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
6. Site Certification
The installer should not leave the site before contacting SpectraLink to perform
remote install verification.
Before leaving the location where the Primary Shelf is installed, the installer must
complete the following items:
ꢁFrom the Operator’s Console, copy the PCS.CFG file to diskette. From the
Operator’s Console, select F1 (Supervisor State) then select Dump Config to
PCS.CFG. See the Operator’s Console document for more information.
ꢁGive the system administrator a map of the system showing the final Base Station
locations at local and remote sites.
ꢁPerform end user and administrative training.
ꢁGet a signature on the acceptance document. This document confirms that the
installation has been correctly carried out, that the coverage area is correct, and that
the client’s personnel have been trained.
The installation is not complete until all certification steps have been performed.
Wireless Telephones should not be handed out until the site has been certified.
Part Number: 72-0059-06-E.doc
Page 24
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
7. Installation Forms
This section contains the following forms:
ꢁBase Station Locations
ꢁExtension Assignments
ꢁSite Preparation Checklist
ꢁCustomer Acceptance Form
Copy these forms as needed. Be sure to maintain completed forms for future reference.
Part Number: 72-0059-06-E.doc
Page 25
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
7.1 Base Station Location Form
Shelf Number: ________ Interface Module: ________
Location
Interface
Module Circuit #
Base Station #
(e.g.: building, floor #, detailed description)
Base Station 1
Base Station 2
Base Station 3
Base Station 4
Base Station 5
Base Station 6
1
2
3
4
5
6
Shelf Number: ________ Interface Module: ________
Location
Base Station #
Interface
Module Circuit #
(e.g.: building, floor #, detailed description)
Base Station 1
Base Station 2
Base Station 3
Base Station 4
Base Station 5
Base Station 6
1
2
3
4
5
6
Shelf Number: ________ Interface Module: ________
Location
Base Station #
Interface
Module Circuit #
(e.g.: building, floor #, detailed description)
Base Station 1
Base Station 2
Base Station 3
Base Station 4
Base Station 5
Base Station 6
1
2
3
4
5
6
Part Number: 72-0059-06-E.doc
Page 26
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
7.2 Extension Assignments Worksheet
Shelf: _______ Interface Module: _______
Interface
Wireless
Telephone
Serial #
Phone #
Ext. #
Name
Module
Comment
Circuit #
Phone 1
Phone 2
Phone 3
Phone 4
Phone 5
Phone 6
Phone 7
Phone 8
Phone 9
Phone 10
Phone 11
Phone 12
Phone 13
Phone 14
Phone 15
Phone 16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Part Number: 72-0059-06-E.doc
Page 27
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
7.3 Site Preparation Checklist
If upon arrival the SpectraLink installer determines that the pre-installation work has not
been completed correctly, the installer has two options: 1) the installer can leave the site
and reschedule the installation when the action items have been completed or corrected,
or 2) the installer can assist in preparing the site, and thus spend additional time
installing the system. Because of the additional cost incurred by SpectraLink in
executing either option, the customer will be billed for the additional time at our
standard hourly rate plus expenses.
Please be sure the following items are completed.
ꢁMCU location prepared. Typically the MCU is installed in the telephone equipment
room. This location must have sufficient rack or backboard space and power
available.
ꢁTwo-pair wires are run to each of the Base Station locations as designated on the
building floor plans. Use Level 3 cable for lengths up to 3,500'; Level 4 for lengths
up to 6,000'.
ꢁThe Base Station cables are terminated with RJ-45 crimp-on plugs at the designated
locations.
ꢁOne (or two) cross-connect block(s) are installed for every Interface Module and
connected with a 25-pair Telco cable terminated with an RJ-21 male connector at the
MCU location.
ꢁThe Base Station cables are terminated at the appropriate cross-connect blocks.
ꢁAnalog or digital ports, one per Wireless Telephone, from the switch are terminated
at the appropriate cross-connect block and the block is labeled with the extensions.
ꢁA dedicated dial line (MB) is available with an RJ-11 jack for the diagnostic modem.
ꢁAn IBM-compatible PC is available to serve as the Operator’s Console for system
administration.
ꢁA system administrator is designated for the SpectraLink system. This person should
be present for the installation. The SpectraLink installer will provide system training
to the system administrator on the day following the installation.
When this checklist is completed please sign, date, and fax to:
(Install Coordination 303-449-7016)
Signature: _______________________________________ Date: _________________
If you have any questions regarding the installation procedure, please call:
SpectraLink Customer Support Hotline 1-800-775-5330
(Monday through Friday, 7 AM to 6 PM MT).
Part Number: 72-0059-06-E.doc
Page 28
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
7.4 Customer Acceptance Form
Customer Name: _______________________________________________________________________
Lease number (if applicable):___________________ Schedule number (if applicable):_______________
This document certifies that ______________________________________, acting as the representative of
____________________________, accepts the installation of the SpectraLink Wireless Telephone System
as set forth on schedule number________________ completed on ______________________, 200_.
A complete installation includes but is not limited to the following items.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
The Master Control Unit (MCU) was installed.
All the Base Stations were installed.
Conversation was verified on all Base Stations.
Conversation was verified on all Wireless Telephones.
Hand-off was verified on all Base Stations.
Coverage was confirmed for the areas specified at time of facilities analysis.
Software was installed on customer’s PC.
A facilities map of the areas of coverage was given to the customer.
Training class was given on use of Wireless Telephones.
Administrative training was given to at least one user.
The following additional parts that were not part of the original order were installed:
Item
Part #
Description & Serial Number
Qty
1
2
3
4
5
The terms and conditions of original Quotation and Sales Agreement apply to all equipment listed above.
_____ I accept the installation of the SpectraLink system as complete.
_____ I decline to installation of the SpectraLink system because:
Customer Signature: ______________________________ Date:____________________
Customer Name (Printed): __________________________________________________
Installer's Signature: ______________________________ Date:____________________
Part Number: 72-0059-06-E.doc
Page 29
SpectraLink Corporation
T1 Remote Module Installation
Link WTS – Link 3000 MCU
Index
Base station location form, 27
Cards
Master Clock, 24
Network Clocked T1, 16
Configuration, 23, 24
Power, 19
Installing, 15, 19
Channel Service Unit, 13
Configuration Requirements
T1, 13
Remote Installation Diagram, 9
Remote Installation, Steps, 11
Remote Shelf
CSU, 13
Configuring, 23
Customer Acceptance Form, 30
Customer Support Hotline, 8
Demarc block, 22
Remote Site
Surveying, 18
Required Materials, 12
Shelves
Diagram, Remote Installation, 9
Expansion Shelf, 14
Connect multiple, 20
Connect to T1 Module, 20
Installing, 19
Installing, 18
Site Certification, 25
Site preparation, 12
Site preparation checklist, 29
System configuration, 23
Remote shelf, 23
Extension assignment worksheet, 28
Forms
Base station location, 27
Customer Acceptance, 30
Extension assignments, 28
Site preparation checklist, 29
GPS timing, 11
T1
Configuration Requirements, 13
Connect at remote site, 20
Connecting at local site, 16
Network Clocked, 16
T1 Remote Module
Connect to Expansion Shelf, 20
Installing at local site, 15
Installing at remote site, 19
Telephone lines, 22
Testing the system, 24
Grounding Strap, 14
Hotline, 8
Icons, 8
Interface Modules, 14
Installing, 19
Intershelf Junction Panel, 15
JPI300, 15
Part Number: 72-0059-06-E.doc
Page 30
|