4-663-202-81(1)
AIT Library
Operating Instructions
Before operating the unit, please read this manual
thoroughly and retain it for future reference.
LIB-81
© 2002 Sony Corporation
ATTENTION
According to the EU Directives related to product safety, EMC and R&TTE the manufacturer of this product is Sony
Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan. The Authorised Representative is Sony Deutschland
GmbH, Hedelfinger Strasse 61,70327 Stuttgart, Germany. For any service or guarantee matters please refer to the
addresses given in separate service or guarantee documents.
AUFMERKSAMKEIT
Im Sinne der EU Richtlinien bezüglich Produktsicherheit, EMV und R&TTE ist Sony Corporation, 1-7-1 Konan
Minato-ku Tokyo, 108-0075 Japan der Hersteller dieses Produktes. Bevollmächtigter ist Sony Deutschland GmbH,
Hedelfinger Strasse 61,D-70327 Stuttgart. Für Service oder Garantieangelegenheiten wenden Sie sich bitte an die in
separaten Service oder Garantiedokumenten angegebenen Adressen.
European Union Restriction of Hazardous Substances Directive compliant.
Entspricht der Richtlinie der Europäischen Union zur Beschränkung der Verwendung
gefährlicher Stoffe.
Für Kunden in Deutschland
Diese Ausrüstung erfüllt die Europäischen EMC-
Bestimmungen für die Verwendung in folgender/
folgenden Umgebung(en):
·Wohngegenden
·Gewerbegebiete
·Leichtindustriegebiete
(Diese Ausrüstung erfüllt die Bestimmungen der Norm
EN55022, Klasse B.)
Betriebsumgebung
Installation
Horizontal
Temperatur
10 °C bis 35 °C
Relative Luftfeuchtigkeit
20% bis 80%
(nicht kondensierend)
Elektrische Eingangsspannung 100 V - 240 V
Daten
Frequenz
Strom
50 / 60 Hz
Modell AIT-5
Modell AIT-4
55W (max.)
55W (max.)
Modell AIT-3 Ex 55W (max.)
ACHTUNG
Modell AIT-3
Modell AIT-2
Modell AIT-1
55W (max.)
50W (max.)
50W (max.)
Zur Trennung vom Netz ist der Netzstecker aus der
Steckdose zu ziehen, welche sich in der Nähe des Gerätes
befinden muß und leicht zugänglich sein soll.
Masse
ca. 13,5 kg
HINWEISE
• Maschinenlärminformations-Verordnung - 3. GPSGV,
der höchste Schalldruckpegel beträgt 70 dB(A) oder
weniger gemäss EN ISO 7779.
• Die 3-adrige Geräteanschlußleitung muß Typ H05VV-F
oder H05VVH2-F sein und nach DIN VDE 0625 geprüft
sein. Der Stecker und die Gerätesteckdose müssen nach
DIN VDE 0620 bzw DIN VDE 0625 geprüft sein. Der
LED Notice:
This product is classified as a CLASS 1 LED
PRODUCT.
Bei diesem Laufwerk handelt es sich um ein LED-
Produkt der Klasse 1.
2
Leitungsquerschnitt kann 0,5 mm betragen wenn die
Anschlußleitung eine Länge von 2 m nicht
überschreitet. Anderenfalls muß der
2
Leitungsquerschnitt mindestens 0,75 mm betragen.
The LED of the barcode reader incorporated inside this
product complies with IEC 60825-1.
LED (barcode reader)
Operating environment
Installation
Horizontal
Temperature
Relative Humidity
10 °C to 35 °C
Wavelength: 630-660 nm
20% to 80% (no condensation)
Ratings Input Voltage 100 V - 240 V
Frequency
Current
50 / 60 Hz
AIT-5 Model
AIT-4 Model
55W (Max)
55W (Max)
AIT-3 Ex Model 55W (Max)
AIT-3 Model
AIT-2 Model
AIT-1 Model
55W (Max)
50W (Max)
50W (Max)
Mass
approx. 13.5 kg
3
Table of Contents
4
5
© 2002 Sony Corporation. All rights reserved.
Trademarks
• Sony, StorStation and Advanced Intelligent Tape are trademarks or registered trademarks of Sony Corporation in this
country, other countries, or both.
• Other product names are trademarks or registered trademarks of their respective owners in this country, other countries,
or both.
6
Introduction
Chapter
Overview
The LIB-81 is an AIT (Advanced Intelligent Tape) library with a built-in AIT
drive. Up to 8 cartridges can be set and used. The unit can also be connected to,
and used with, a workstation or server.
Up to 8 cartridges can be set
Up to 8 AIT cartridges can be set. Cartridges can be replaced from the front
panel. When the AIT library is equipped with a bar code reader, bar code labels
can be used to manage cartridges. The following types of cartridges can be used
in this library:
LIB-81/A5 models
• AIT-5 cartridge:
• AIT-4 cartridge:
• AIT-3 Ex cartridge:
• AIT-3 cartridge:
can record up to 3200 GB of data
can record up to 1600 GB of data
can record up to 1200 GB of data
can record up to 800 GB of data
LIB-81/A4 models
• AIT-4 cartridge:
• AIT-3 Ex cartridge:
can record up to 1600 GB of data
can record up to 1200 GB of data
LIB-81/A3X models
• AIT-3 Ex cartridge:
• AIT-3 cartridge:
can record up to 1200 GB of data
can record up to 800 GB of data
• AIT-2 Turbo cartridge: can record up to 640 GB of data
LIB-81/A3 models
• AIT-3 cartridge:
• AIT-2 cartridge:
• AIT-1 cartridge:
can record up to 800 GB of data
can record up to 400 GB of data
can record up to 280 GB of data
LIB-81/A2 models
• AIT-2 cartridge:
• AIT-1 cartridge:
can record up to 400 GB of data
can record up to 280 GB of data
LIB-81/A1 models
• AIT-1 cartridge:
can record up to 280 GB of data
7
Chapter 1 Introduction
Notes
• Cartridges that can be used vary according to the type of built-in drive.
• The memory capacity mentioned above assumes the use of all 8 AIT
cartridges, no compression.
• For combinations other than those mentioned above, refer to the attached
sheet.
The AIT library can be remotely controlled
A browser can be used to configure individual settings. It can also be used to
view library and maintenance information.
LVD SCSI compliant
The LIB-81/A5, LIB-81/A4, LIB-81/A3X, and LIB-81/A3 models are Ultra
160 LVD SCSI-compliant, whereas the LIB-81/A2 and LIB-81/A1 models are
Wide Ultra LVD SCSI-compliant.
Suitable for rack mounting
With the ACY-RK81 rack mounting kit (sold separately), the AIT library can
be installed on an EIA-standard, universal pitch 19-inch rack. Contact your
dealer for information about the rack mounting kit.
Product Features and Functions
Front
1 2
3
4
5
7
6
1
2
3
4
5
7
6
8
Chapter 1 Introduction
A Front Panel
There are two shapes for the front panel.
B Power Indicator LED
This LED light is on when the power is turned on.
C Cartridge Dock
Load and exchange cartridges in the cartridge dock. When the cartridge dock is
specified using the control buttons, its shutter opens automatically. The library
does not operate while the cartridge dock shutter is open, so close the shutter
using the control buttons after loading or exchanging cartridges.
D Liquid Crystal Display
The LCD panel displays information such as the operating status. When in
normal standby state, it displays the status of the AIT library.
E Control Buttons
These buttons are used to control operations through the Control Panel Menu.
F Error LED
This LED light is on when an error occurs.
G Ventilation Holes
Please be careful not to block the ventilation holes. If the ventilation holes are
blocked, the AIT library may overheat, resulting in fire or other damage.
Rear
1
2
3
4
5
67
A Power Supply Connector
Plug the provided power cord into this connector.
B Power Switch
Press this switch to turn the library on and off.
C Fan Unit
Please be careful not to block the ventilation holes. If the ventilation holes are
blocked, the AIT library may overheat, resulting in fire or other damage.
D Transport Screw
During installation, remove the transport screw and set it in the bottom hole
(Operation position). Before transport, make sure that you read “Transporting
transport screw is in the upper hole (Shipping position).
9
Chapter 1 Introduction
E SCSI connector 1 6 SCSI connector 2
For information about connecting the SCSI connectors, refer to “Connecting to
G LAN Connector
Connect a 10Base-T/100Base-TX network cable here.
Bottom
DIP Switches for Setup
The default setting of the DIP switches is as follows. Use the DIP switches as is.
System Structure
Generally, the library is connected to the host computer and used to control the
library from the host computer. Also, you can connect the library to the network
so that it can be configured and maintained through a browser.
Make library settings and
perform maintenance.
Ethernet
Control the
library.
SCSI
Host computer
LIB-81
Notes
• A SCSI host adapter card must be installed in the host computer.
• In order to configure and maintain the library through a browser, browser
software must be installed in the computer. The following operating systems
and browsers are compatible with the library.
10
Chapter 1 Introduction
Operating systems:
- Microsoft Windows 95, Microsoft Windows 98, Microsoft Windows Me,
and Microsoft Windows 2000
Browsers:
- Microsoft Internet Explorer 5.01 or later
- Netscape Communicator 4.7 or later
Compatible Data Cartridges
This section describes data cartridges used in the AIT library.
AIT Cartridges
AIT cartridges for use with your built-in AIT drive can be used in the AIT
library. To achieve the maximum transfer rate and recording capacity, use the
optimum cartridges for your type of AIT drive. For information on recording
chapter.
Built-in AIT-5 drive (LIB-81/A5 models)
AIT-3 mark
AIT-5 mark
AIT-4 mark
AIT-3 Ex mark
Built-in AIT-4 drive (LIB-81/A4 models)
AIT-4 mark
AIT-3 Ex mark
Built-in AIT-3 Ex drive (LIB-81/A3X models)
AIT-3 Ex mark
AIT-3 mark
AIT-2 Turbo mark
AIT-2 mark*
AIT-1 Turbo mark*
AIT-1 mark*
AIT-E Turbo mark*
* Only supports read operations
Built-in AIT-3 drive (LIB-81/A3 models)
AIT-3 mark
AIT-2 mark
AIT-1 mark
Built-in AIT-2 drive (LIB-81/A2 models)
AIT-2 mark
AIT-1 mark
11
Chapter 1 Introduction
Built-in AIT-1 drive (LIB-81/A1 models)
AIT-1 mark
Caution
• Do not use 8 mm video tapes sold at stores. An 8 mm video tape looks a lot
like an AIT cartridge, but has different specifications. Do not use any
cartridge other than those listed above. Use only designated AIT data
cartridges.
• For combinations other than those mentioned above, refer to the attached
sheet.
Cleaning Cartridges
To clean the AIT drive, use an AIT Cleaning cartridge. There are four types of
cleaning cartridges: the SDX5-CL for use with AIT-5 drives; SDX4-CL or
SDX4-CLL for use with AIT-4 drives; SDX3X-CL for use with AIT-3 Ex
drives; and SDX1-CL for use with AIT-3, AIT-2, and AIT-1 drives. Make sure
that you use the cleaning cartridge appropriate for your drive. For information
Software
For guidance on application software that can be used with the AIT library and
supported operating systems, contact your dealer.
Precautions
• In the cartridge slots, use the optimum cartridges for your type of AIT drive.
Using cartridges other than AIT cartridges may cause malfunctions. For
information about cartridges that can be used with the AIT library, refer to
• Do not insert anything except AIT cartridges in the cartridge dock, as doing
so may result in damage.
• If the unit is suddenly taken from a cold to a warm location, or if ambient
temperature suddenly rises, moisture may form on the outer surface and/or
inside of the unit. This is known as condensation. If condensation occurs, put
the unit aside without turning it on and wait until the condensation clears. Do
not use the unit in such a state, as this may damage it.
12
Chapter 1 Introduction
Installation
Chapter
Overview
This chapter explains general procedures for positioning the AIT library,
connecting it to the host computer and turning on the library power. This chapter
also explains initial setup. Installation and setup steps may vary depending on
your system.
After turning on the power, make settings required to use the unit as explained
Unpacking
Note
You will need the box, packing materials and transport screw if you wish to
move or transport the AIT library in the future. Retain them for future use.
1
Remove the AIT library from the box as indicated on the box.
Remove the packing materials, such as plastic covers and tapes.
13
Chapter 2 Installation
2
Remove the transport screw (turn counterclockwise) from the Shipping
position (upper hole) at the rear of the library, and then set it in the
Operation position (lower hole) with a screw driver or coin.
Transport screw
Operation position
Checking the Package Contents
After opening the package, make sure all of the following items are present.
Contact your dealer if anything is missing.
• LIB-81 AIT Library (1)
• Power cable (1)
• SCSI terminator (1)
• Quick Start Guide (1)
• Air Filter (ACY-FL81) (4)
• Bar code labels (1 sheet; only supplied with models equipped with a bar code
reader)
• Safety Notice (1)
Note
In addition to the above, other documentation, cables, and cleaning cartridges
may also be included.
Preparing the Host Computer
To prepare the host computer before installing the AIT library:
1
2
Make sure that a SCSI host adapter card is installed in the host computer.
Install the application software supporting the library on the host computer.
For guidance on application software that can be used with the AIT library
and supported operating systems, contact your dealer.
14
Chapter 2 Installation
Installing the AIT Library
The library weighs about 13.5 kg (29.8 lb.) and has the following dimensions.
Before installing the library, make sure that the surface on which you are placing
it is large and strong enough.
43 mm
(1.75 in.)
(1U)
Also, set the library horizontally so that its front and sides are inclined by no
more than 1 degree in any direction.
Front
Side
15
Chapter 2 Installation
With the ACY-RK81 rack mounting kit (sold separately), the AIT library can
be installed on an EIA-standard, universal pitch 19-inch rack. Contact your
dealer for information about the rack mounting kit.
Note
Install the AIT library on a horizontal surface near an AC power outlet. Also,
leave a gap of about 150 mm (5.9 in.) behind the rear of the unit to allow air to
circulate.
Rear
150 mm
(5.9 in.)
Front
430 mm (16.9 in.)
660 mm (26.0 in.)
Connecting the Power Cable
1
Confirm that the power switch on the rear of the AIT library is turned off
(a is pressed).
2
Connect one end of the power cable to the power supply connector and the
other end to the power outlet.
16
Chapter 2 Installation
Connecting to the Host Computer
Connect the AIT library and the host computer with a SCSI cable. This section
explains general connecting steps. Connect the library with the appropriate
SCSI cable, depending on the AIT drive.
• When the library is equipped with the AIT-5, AIT-4, AIT-3 Ex, or AIT-3
drive, use a generic Ultra 160 cable.
• When the library is equipped with the AIT-2 or AIT-1 drive, use a generic
Wide Ultra LVD SCSI cable that conforms to SCSI-3.
The library side uses the 68-pin half pitch connector.
When connecting other SCSI devices together with the AIT library, see
Caution
• Do not connect the AIT library to an HVD (High Voltage Differential) SCSI
bus. If connected, the library or other devices on the SCSI bus may be
damaged.
• When connecting the SCSI cable, turn off all of the connecting devices,
including the AIT library and the host computer.
• When connecting the AIT library as the last device on the SCSI bus, be sure
to attach the provided terminator.
• In LVD (Low Voltage Differential) SCSI, make the total length of the SCSI
cable (internal and external), which connects the host computer and the device
at the end of the SCSI bus, shorter than 12 meters (39 ft. 4.4 in). (The length
of the AIT library internal cable is 2 meters (78.7 in.).)
• SCSI cables cannot be branched.
Notes
• Prepare the necessary SCSI cables. For information about SCSI cable
specifications, refer to “SCSI Cable and Terminator Specifications” (page 96)
1
2
Confirm that the host computer and AIT library are turned off.
Attach the SCSI cable and terminator as shown in the figure below.
1 Use a SCSI cable (sold in stores) to connect the AIT library to the host
computer.
17
Chapter 2 Installation
2 Attach the provided terminator to the other connector.
Host computer
1
2
Terminator
Setting the DIP Switches
DIP switch settings determine whether electric power is supplied to the SCSI
terminator (when multiple SCSI devices are connected).
DIP Switches for Setup
Bottom
The default factory setting of the DIP switches is as follows.
1-7: On (Do not change this default setting.)
Used for expansion purposes
8: On
ON: SCSI TERM POWER ON
OFF: SCSI TERM POWER OFF
To set the DIP switches:
18
Chapter 2 Installation
1
2
Press the power switch to turn off the power.
Use a pointed object such as a machinist’s screwdriver to change the
settings of the DIP switches.
3
Press the power switch to turn on the power.
Connecting SCSI Peripheral Devices
SCSI peripheral devices can be connected to the SCSI connectors of the AIT
library. The SCSI configuration of the library is as shown below. Connect the
devices according to the system environment.
Library
SCSI Connector 2
SCSI Connector 1
AIT Drive
Library
Controller
Notes
• The default factory settings of the SCSI IDs are as follows.
- Library:
0
- AIT Drive: 1
• Do not use repetitive SCSI IDs.
Turning the Power On/Off
Turn the Power On
Turn on the AIT library power, then turn on the host computer power.
19
Chapter 2 Installation
1
Press the power switch on the rear of the library.
The messages on the right appears
and the startup process begins.
(Startup takes several minutes.)
LIB-81
Initializing
When the startup process ends, the
library enters the time setting mode.
Jan/01/2001 12:00:00
[ENTER] to set the
Date and Time
[CANCEL] to exit
Caution
Models equipped with a bar code
reader
By default, the library is not set to
read bar codes. If you modify this
setting so that the library can read
bar codes and use cartridges without
bar code labels, initialization after
turning on the library takes
unusually long. For details about
how to set the library to read bar
Models without a bar code reader
Modifying the default setting so that
the library can read bar codes
generates an error. You should not
modify this setting.
2
If you want to change the date and time, press the [ENTER] button. If you
do not want to make changes, press the [CANCEL] button.
For details about the date and time settings, see “Setting the Date and
Once the library is started, the status
display on the right appears.
READY
AIT3
1 2 3 4
5 6 7 8
20
Chapter 2 Installation
Notes
• The date and time cannot be updated when the AIT library is off. For this
reason we recommend that you set the date and time each time you turn
on the library.
• If the library is left idle for five minutes, the status display appears
automatically.
3
After pressing the standby switch on the library's front panel, wait at least
10 seconds before turning on the host computer.
When using DHCP, wait at least 30 seconds.
Then, go to “Initial Setup” (page 22).
Notes
• If you start the host computer before the library, the SCSI ID is not
detected correctly. Therefore, always start the library before starting the
host computer.
Turn the Power Off
Before turning off the library, perform the system shutdown procedure from the
control panel. After you have performed the procedure, you can turn off the
library.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select
“9. System Down,” then press the
[ENTER] button.
Menu
12:34
12:34
7.Tape Inventory
8.Password
9.System Down
3
4
Select “2. Shutdown,” then press
the [ENTER] button.
System Down
1.Reset
2.Shutdown
When “[ENTER] to activate”
appears, press the [ENTER] button.
Shutdown
[ENTER] to activate
The system performs the shutdown
procedure.
Shutdown
*** Wait a minute ***
5
When the message on the right
appears, turn off the library by
pressing the power switch on the
rear.
Ready for shutdown
Press the power
switch on the rear
of the Library
Caution
• Even though pressing the rear power switch can turn off the library power,
following the above steps is recommended.
21
Chapter 2 Installation
• After turning the AIT library power off, wait at least 10 seconds before
turning it on again.
• Before transport make sure that you turn off the AIT library using the
procedure above, and that the transport screw is in the Shipping position.
Note
To avoid pressing the control buttons by accident, you can disable the control
buttons. For information on how to disable the switch, refer to “Disabling the
Initial Setup
Once the library has started, perform the initial setup as follows:
1
2
3
4
Set the date and time. (page 22)
Set the SCSI IDs of the AIT library and AIT drives if necessary. (page 23)
Set the cartridges. (page 25)
Configure the application programs on the host computer for use with the
unit.
Follow the instructions given in the application software manual to set up
the software for the library.
5
Connect to a network if necessary. (page 29)
Setting the Date and Time
Use the Configuration Menu of the control panel to set the date and time.
Notes
• The date and time can also be set through a browser.
• The date and time cannot be updated when the AIT library is off.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “5.Configuration”, then press the
[ENTER] button.
3
Select “1.Date & Time”, then press
the [ENTER] button.
Configuration 12:34
1.Date & Time
2.Warning
3.Barcode
Date and Time appears.
Jan/01/2001 12:00:00
Japan
(GMT+ 9:00)
22
Chapter 2 Installation
4
5
Set the month, day, and year.
1 When the month digits flash, use the V and v buttons to set the month,
then press the [ENTER] button.
2 When the day digits flash, use the V and v buttons to set the day, then
press the [ENTER] button.
3 When the year digits flash, use the V and v buttons to set the year then
press the [ENTER] button.
Set the hour, minute, and second.
1 When the hour digits flash, use the V and v buttons to set the hour, then
press the [ENTER] button.
2 When the minute digits flash, use the V and v buttons to set the minute,
then press the [ENTER] button.
3 When the second digits flash, use the V and v buttons to set the second
then press the [ENTER] button.
6
7
When the country flashes, use the V and v buttons to set the country, then
press the [ENTER] button.
When “[ENTER] to activate”
appears, press the [ENTER] button.
Jan/01/2001 12:00:00
Japan
(GMT+ 9:00)
[ENTER] to activate
The date and time and the country
are now set. The display returns to
the menu.
8
Press the [CANCEL] button twice to return to the status display.
Setting the SCSI ID
Use the SCSI Menu of the control panel to set the SCSI IDs and SCSI parity of
the AIT library and AIT drives.
Library
SCSI Connector 2
AIT Drive
SCSI Connector 1
Library
Controller
About SCSI ID
For each SCSI bus, a unique SCSI ID must be set for the AIT library and AIT
drives. The default factory settings of SCSI IDs are as follows:
• Library:
• AIT Drive:
0
1
23
Chapter 2 Installation
About SCSI parity
When the SCSI parity function is enabled, parity checks are performed on all
data passing through the SCSI bus. The factory default settings for SCSI parity
are as follows:
• Library:
• AIT Drive:
Enabled (YES)
Enabled (YES)
Caution
Do not duplicate SCSI IDs.
Note
The SCSI IDs can also be set through a browser.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “4.SCSI”, then press the [ENTER]
button.
3
Set the SCSI ID and SCSI parity of
the library.
ID Parity
Library 01 YES
Drive
02 NO
1 When the “ID” of “Library” setting flashes, use the V and v buttons to
set the SCSI ID, then press the [ENTER] button.
2 When the “Parity” setting flashes, use the V and v buttons to set the SCSI
parity, then press the [ENTER] button.
Select “YES” to enable the SCSI parity function.
4
5
In the same manner, set the AIT Drive.
When “[ENTER] to activate”
ID Parity
appears, press the [ENTER] button.
Library 01 YES
Drive
02 NO
[ENTER] to activate
6
When “[Enter] to reset” appears,
press the [ENTER] button.
Warning
12:34
Reboot the system to
activate the setting
[ENTER] to reset
The system reboots.
Caution
If you change the SCSI ID while the library is connected to the host
computer, you must also restart the host computer.
24
Chapter 2 Installation
Setting the Cartridges
Prepare a cartridge and set it into the AIT library.
Preparing the Cartridge
Check the erase-protection tab and prepare your cartridge for use. If you are
using a model equipped with a bar code reader, you can manage cartridges with
bar code labels. Affix bar code labels to your cartridges as necessary. If you are
using a model without a bar code reader, proceed to step 2.
Note
The type of bar code is fixed to Code 39 with check digit for models equipped
with a bar code reader. We recommend that you use Sony bar code labels for the
AIT library (sold separately). If you use other types of bar code labels, you may
encounter recognition problems. For details about Sony bar code labels, see
1
Affix bar code labels as necessary.
Affix the barcode label in the position shown in the figure, orienting it so
that the numbers are at the top.
Bar code label
Caution
Models equipped with a bar code reader
By default, the library is not set to read bar codes. If you modify this setting
so that the library can read bar codes and use cartridges without bar code
labels, initialization after turning on the library becomes unusually long.
For details about how to set the library to read bar codes, see Chapter 3,
Models without a bar code reader
Modifying the default setting so that the library can read bar codes
generates an error. You should not modify this setting.
25
Chapter 2 Installation
2
Check whether the erase-protection tab is set to the write-enable position.
If the tab is orange, data can be written to the cartridge.
AIT-1
AIT-5, AIT-4, AIT-3 Ex, AIT-3, AIT-2 Turbo,
AIT-2, AIT-1 Turbo, AIT-E Turbo
Lid
Lid
If the tab is moved to the left, data
can be written to and erased from
the cartridge.K
If the tab is moved to the right, data
cannot be written or accidentally
erased from the cartridge.k
If the tab is lowered, data can be
written to and erased from the
cartridge.j
If the tab is raised, data cannot be
written to or accidentally erased
from the cartridge.J
Setting the Cartridge
Set the cartridge into the AIT library. When setting the cartridge, specify the slot
by its element address. For information about element addresses, refer to
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “2.Eject/Insert”, then press the [ENTER]
button.
“Eject/Insert” appears.
3
4
Select “3.Insert Into Library”, then
press the [ENTER] button.
Eject/Insert
12:34
1.Eject From Library
2.Eject From Drive
3.Insert Into Library
Select the cartridge insertion
method, then press the [ENTER]
button.
Insert
1.Single Mode
2.Multiple Mode
12:34
• When you want to specify a slot
and insert the cartridge in it, select
“1. Single Mode”.
• When you want to insert several
cartridges consecutively, select
“2. Multiple Mode”. In this case,
you only need to specify the first slot.
5
Use the V and v buttons to set the
Slot 01
element address of the slot where
the cartridge is going to be set, then
press the [ENTER] button.
26
Chapter 2 Installation
6
When “[ENTER] to activate”
appears, press the [ENTER] button.
Slot 01
[ENTER] to activate
The cartridge dock shutter opens.
7
Insert the cartridge in the slot.
Be sure to insert it all the way.
27
Chapter 2 Installation
8
If you selected “1. Single Mode” in
step 4, press the [CANCEL] button.
Slot 01
Insert Tape
[CANCEL] to exit
Note
Even if you selected “1. Single
Mode” in step 4, you can insert a
different cartridge by using the V
and v buttons to select the slot
element address, and then pressing
the [ENTER] button. Because you
did not select “2. Multiple Mode” in
step 4, the cartridge dock shutter
closes and reopens. When it does,
you can insert another cartridge as
explained above. If you do so, when
you are done inserting cartridges
press the [CANCEL] button and
proceed to step 10.
9
If you selected “2. Multiple Mode” in step 4, perform the following
depending on the number of open slots.
Two or more open slots
Insert Tape Slot 01
The slot moves to the next one.
When it stops, insert another
cartridge and press the [ENTER]
button again. Repeat until all the
cartridges are inserted, then press
the [CANCEL] button.
Next Slot 02
[CANCEL] to exit
[ENTER] to next slot
1 Insert a cartridge and press the
[ENTER] button.
2 The slot moves to the next. Insert
another cartridge in the same
manner and press the [ENTER]
button.
When you press the [ENTER]
button, the slot moves to the next.
3 Repeat until all the cartridges are
inserted, and then press the
[CANCEL] button.
Only one open slot
The element address of the front
slot appears on the first line.
(Nothing appears on the second
line.)
Insert Tape Slot 01
[CANCEL] to exit
1 Insert a cartridge and press the
[CANCEL] button.
Caution
Do not put your fingers in the slot when it is moving, as this could result in
injuries.
28
Chapter 2 Installation
10 When “[ENTER] to activate” appears, press the [ENTER] button.
If you selected “1. Single Mode” in
step 4, the display on the right
appears.
Slot 01
Exit ?
[ENTER] to activate
If you selected “2. Multiple Mode”
in step 4, the display on the right
appears.
Insert Tape Slot 01
Exit ?
[ENTER] to activate
The shutter closes and the
initialization is performed.
Slot 01
Initializing
11 When the initialization ends, press the [CANCEL] button three times to
return to the status display.
Connecting to the Network
If the AIT library is connected to the network, a browser can be used to
configure the library and view status information.
Connect the AIT library to the network as follows.
1
Setup the network.
2
3
4
Connect a network cable.
Restart the library.
Access the library from a browser.
Notes
• For information about how to use the browser to configure individual settings
and view status information, refer to Chapter 6, “Library Administration
• In order to configure and maintain the library through a browser, browser
software must be installed in the computer. The following operating systems
and browsers are compatible with the library.
Operating systems:
- Microsoft Windows 95, Microsoft Windows 98, Microsoft Windows Me,
and Microsoft Windows 2000
Browsers:
- Microsoft Internet Explorer 5.01 or later
- Netscape Communicator 4.7 or later
Setting the Network
In order to connect to the network, use the Network Menu of the control panel
to configure the necessary settings, such as the IP address setting.
29
Chapter 2 Installation
Notes
• After connecting to the network, a browser can be used to change network
settings.
• The AIT library does not support DNS. (You do not need to set the [Host],
[Domain], or [DNS] settings in the procedure below.)
• You can obtain the AIT library’s MAC address from the Network Menu.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select
“6.Network”, then press the
[ENTER] button.
Menu
12:34
12:34
4.SCSI
5.Configuration
6.Network
“Network” appears.
3
4
When you want to set the host
name, select “1.Host”, then press
the [ENTER] button. (However, the
AIT library does not support DNS,
therefore this setting is
Network
1.Host
2.Domain
3.IP Address
unnecessary.)
When the “Host” setting flashes, set
the host name. (However, the AIT
library does not support DNS,
therefore this setting is
Host
■
unnecessary.)
If no setting has been made, a flashing rectangle appears.
• In order to change the host name, use the V button, the v button, the
[ENTER] button and the [CANCEL] button to enter the new host name,
then press the [ENTER] button. First, make sure that the same host name
does not exist in the same network, then enter the host name.
- Enter the host name up to 63 alphanumeric characters and symbols ( -
. ).
- To delete a character, use space (“ ”).
5
When [[ENTER] to activate]
appears, press the [ENTER] button.
Host
LIB-81
[ENTER] to activate
The display returns to “Network”.
6
7
When you want to set the domain name, select “2.Domain”, then press the
[ENTER] button. (However, the AIT library does not support DNS,
therefore this setting is unnecessary.)
When the “Domain” setting flashes, set the domain name.
If no setting has been made, a flashing rectangle appears.
• In order to change the domain name, use the V button, the v button, the
[ENTER] button and the [CANCEL] button to enter the new domain
name, then press the [ENTER] button.
- Enter the domain name up to 63 alphanumeric characters and symbols
( - . ).
- To delete a character, use space (“ ”).
30
Chapter 2 Installation
8
9
When [[ENTER] to activate]
appears, press the [ENTER] button.
Domain
XXX
[ENTER] to activate
The display returns to “Network”.
When you want to set the IP address, select “3.IP Address”, then press the
[ENTER] button.
• Select “YES” to use the IP address assigned to the DHCP server. Then
proceed to step 12.
• Select “NO” to use the fixed IP address. Then proceed to step 10.
10 When the “IP” setting flashes, use the V button, the v button, the [ENTER]
button and the [CANCEL] button to set the IP Address, then press the
[ENTER] button.
11 When the “Mask” setting flashes, use the V button, the v button, the
[ENTER] button and the [CANCEL] button to set the subnet mask, then
press the [ENTER] button.
12 When [[ENTER] to activate]
DHCP YES
appears, press the [ENTER] button.
IP 000.000.000.000
Mask 000.000.000.000
[ENTER] to activate
The display returns to “Network”.
13 When you want to set the default gateway, select “5.Gateway”, then press
the [ENTER] button. (However, the AIT library does not support the
default gateway setting.)
14 When the “Gateway” setting flashes, use the V button, the v button, the
[ENTER] button and the [CANCEL] button to set the IP address for the
default gateway, then press the [ENTER] button.
15 When [[ENTER] to activate]
Gateway
appears, press the [ENTER] button.
000.000.000.000
[ENTER] to activate
The display returns to “Network”.
16 When you want to obtain the MAC address, select “6.MAC Information”,
then press the [ENTER] button.
The MAC address is displayed.
MAC Address
00-00-00-00-00-00
17 Press the [CANCEL] button twice to return to the status display.
18 Use the V and v buttons to select
Menu
12:34
“9. System Down”, then press the
[ENTER] button.
7.Tape Inventory
8.Password
9.System Down
31
Chapter 2 Installation
19 Select “2. Shutdown”, then press
System Down
1.Reset
2.Shutdown
12:34
the [ENTER] button.
20 When “[ENTER] to activate”
Shutdown
appears, press the [ENTER] button.
[ENTER] to activate
The system performs the shutdown
procedure
Shutdown
*** Wait a minute ***
21 When the message on the right
appears, turn off the library by
pressing the power switch on the
rear.
Ready for shutdown
Press the power
switch on the rear
of the Library
Connecting a Network Cable
When the network settings are done and the library turned off, connect the
network cable.
1
Connect a network cable from the hub to the Ethernet connector on the
library.
2
Turn on the library power.
Accessing the AIT Library From a Browser
Use a browser to check whether the library is connected to the network.
1
2
Launch a browser on a client computer.
Enter “http://XXX.XXX.XXX.XXX/” in the “Address” or “Location”
field.
For “XXX.XXX.XXX.XXX”, enter the IP address set in the library.
(e.g., 192.168.0.1)
Note
If the IP address assigned by a DHCP server is being used, enter the current
IP address in the “Address” field of the browser. The current IP address can
be checked with [IP Address] of the Network Menu of the control panel.
The top page of the Library Administration Menu appears.
32
Chapter 2 Installation
(Example) When using Microsoft Internet Explorer
33
Chapter 2 Installation
Basic Usage
Chapter
Overview
This chapter explains the control panel, basic settings, handling the cartridges,
element addresses assignments and daily maintenance.
Control Panel
The control panel can be used to configure the AIT library settings, the AIT
drive settings and the network settings. It can also be used to display individual
information about the AIT library.
This section explains operation of the control panel, the control buttons and
menu items.
For details on the menu and how to configure the settings, see each related
reference.
Caution
This document contains explanations for all LIB-81 models (A5, A4, A3X, A3,
A2, and A1). We have used LIB-81/A3 displays to illustrate the explanations.
The display of models other than the LIB-81/A3 differs slightly, but operation
is similar to the LIB-81/A3.
Usage of the Control Panel
The following tasks can be accomplished using the control panel:
• Configure AIT library and AIT drive-related settings
• Configure network related settings
• Display information related to the AIT library
• Test hardware
Note
Some of the setups and operations can be performed through a browser.
34
Chapter 3 Basic Usage
Viewing the Status Display
During the normal active state, the status information is displayed on the LCD
panel of the AIT library.
READY
1 2 3 4
AIT3
5 6 7 8
A Current operation of the library and AIT drive
The meanings of the messages displayed for the AIT library are:
“READY”: Waiting
“PICK”:
“MOVE”:
“PUT”:
The picker has gone after the cartridge
The cartridge is moving
The cartridge is being set into the AIT drive or slot
The meanings of the messages displayed for the AIT drive are:
“WRITE”: The AIT drive is writing data
“READ”:
The AIT drive is reading data
“ERASE”: The AIT drive is erasing data
“SPACE”: The AIT drive is reorganizing data
“RWND”: The AIT drive is rewinding the cartridge
“CLEAN”: The AIT drive is cleaning the drum head
“LOAD”:
“UNLD”:
The AIT drive is being loaded
The AIT drive is being unloaded
Caution
There may be a lag between the actual operational status of the drive and the
information on the LCD panel.
B Type of AIT drive
The type of AIT drive appears at the bottom left of the display. When setting
cartridges, check this display and make sure the cartridges are of the same type.
C Position of cartridges set in slots
If cartridges are set in the AIT library slots, the numbers of the corresponding
slots are displayed in reverse video.
D Position of cartridges set in the AIT drive
If a cartridge is present inside the AIT drive or its cartridge slot,
is
displayed.
If a cartridge is not present inside the AIT drive or its cartridge slot,
displayed.
is
(Example) If cartridges are set in slots 1 and 8, and AIT Drive
READY
1 2 3 4
AIT3
5 6 7 8
E Picker
The picker is displayed as V.
When the picker has picked up and is conveying a cartridge,
is displayed.
35
Chapter 3 Basic Usage
Note
The status information can be viewed through a browser. Refer to Chapter 6,
Menu Items
The following menus are in the control panel.
MENU
Information
System Down
Password
Eject / Insert
Move Tape
SCSI
Tape Inventory
Network
Configuration
Information Menu
The AIT library and AIT drive information can be displayed.
The following submenus are in the Information Menu.
MENU
Information
ENTER
Library
Drive
• Library Menu
Displays information related to the AIT library.
• Drive Menu
Displays information related to the AIT drives.
36
Chapter 3 Basic Usage
Eject/Insert Menu
Use this menu to set and replace the cartridges.
The following submenus are in the Eject/Insert Menu.
MENU
Eject / Insert
ENTER
Eject From
Library
Insert Into
Eject From Drive
Library
• “Eject From Library”
Ejects the cartridge from the AIT library.
• “Eject From Drive”
Ejects the cartridge from the AIT drive, but does not move it to a slot.
• “Insert Into Library”
Loads a cartridge into the AIT library.
Move Tape Menu
SCSI Menu
This menu moves the cartridges.
The SCSI IDs and SCSI parities of the AIT library and AIT drives can be set.
37
Chapter 3 Basic Usage
Configuration Menu
The date and time, warning message displayed, bar code, R-MIC and brightness
of the LCD panel can be configured.
The following submenus are in the Configuration Menu.
MENU
Configuration
ENTER
Date & Time
Sequential Mode
LCD Contrast
Warning
Bar Code
R-MIC
• “Date & Time”
Set the date and time.
• “Warning”
Set whether or not to display the life warning (given when a specific part has
been operated more times than the specified number of times).
• “Barcode”
If you are using a model equipped with a bar code reader, configure so that the
bar codes affixed to cartridges can be read.
• “R-MIC”
If you are using a model equipped with an R-MIC reader, only enable the
R-MIC function if you use AIT-5, AIT-4, AIT-3 Ex, or AIT-3 cartridges, or
AIT cartridges with R-MIC.
• “LCD Contrast”
Set the brightness of the LCD panel.
• “Sequential Mode”
Activate the sequential mode.
Caution
There exist LIB-81 AIT library models without bar code or R-MIC readers.
Make sure that your library is equipped with a bar code and/or R-MIC reader
before modifying the “Barcode” or “R-MIC” setting. Modifying these settings
when using LIB-81 AIT library models that are not equipped with the
appropriate readers generates errors.
38
Chapter 3 Basic Usage
Network Menu
Necessary settings can be configured in order to connect to the network.
Tape Inventory Menu
Information related to the cartridges can be displayed.
The following submenus are in the Tape Inventory Menu.
MENU
Tape Inventory
ENTER
Barcode
R-MIC
• “Barcode”
Displays the bar code information.
• “R-MIC”
Displays the R-MIC information.
Password Menu
A password can be assigned to the AIT library. The password is used when
accessing certain menus through your network.
System Down Menu
This menu is used when shutting down and restarting the system. It is essential
to perform the shutdown procedure before turning off the AIT library with the
power switch.
Control Buttons
The following buttons are on the control panel. Use these buttons to operate the
Control Panel Menu.
[MENU] button
The Control Panel Menu appears.
v button, V button
These buttons are used to select a menu and to input letters and numbers.
• Press v to move to the previous menu, and V to move to the next menu.
39
Chapter 3 Basic Usage
• Press v to cycle forward through letters and numbers one at a time, and V to
cycle backwards.
[ENTER] button
This button is used to finalize the displayed menu or value, set alphanumerical
characters, and perform operations.
• Finalizes or executes the displayed menu or operation.
• Moves the cursor right.
• Saves the values.
• Input a space (“ ”) to delete unwanted character.
[CANCEL] button
Used to cancel the current operation and set alphanumerical characters.
• Returns to the previous menu.
• Moves the cursor left.
(Operation example) Set the host name
1
2
When the server is in the normal standby state, press the [MENU] button
for two seconds.
Use the V and v buttons to select
“6.Network”, then press the
[ENTER] button.
Menu
4.SCSI
12:34
5.Configuration
6.Network
“Network” appears.
3
Select “1.Host”, then press the
[ENTER] button.
Network
1.Host
12:34
2.Domain
3.IP Address
“Host” appears, and the first
character of the host name flashes.
Host
LIB-81
4
5
Use the V and v buttons to input the first character.
Press the [ENTER] button to flash the next character, then input the
character.
6
Repeat Step 5 to input the rest of the
characters.
Host
MACHINE-NAME
7
8
Press the [ENTER] button.
When [[ENTER] to activate]
appears, press the [ENTER] button.
HOST
MACHINE_NAME
Host name is now set, and the
display returns to “Network”.
[ENTER] to activate
9
Press the [CANCEL] button twice to return to the status display.
40
Chapter 3 Basic Usage
Warnings
When the AIT drive needs cleaning or a specific part needs to be replaced upon
reaching its periodic replacement time, a warning message is displayed on the
LCD panel.
Warning
Cleaning request
12:34
The warning messages and their solutions are as follows:
“Cleaning Request”:
The AIT drive needs to be cleaned.
Clean the AIT drive. For information about how to clean the drive,
“Threshold Condition Met”:
The specific part has operated more than the specified number of
times.
Since the specific part has reached the periodic exchange time,
contact the service and support center.
“Drive Information”:
An error occurred in the AIT drive. A two-digit error code appears
after the warning message. For details about these codes, see “Other
“FanX trouble”:
An anomaly has occurred at fan X (where X is the fan number).
Contact your nearest Sony Service Support Center.
“Cleaning Tape at EOM”:
The spent cleaning cartridge is set. Replace the spent cleaning
cartridge with a new one.
“Clean failure”:
Cleaning failed. Repeat the cleaning procedure.
Errors
When an error occurs in the AIT library, an error code appears on the LCD
panel.
the “Appendix” chapter.
Error
********
12:34
41
Chapter 3 Basic Usage
Setting or Changing the Password
A password can be set on the AIT library. The password is used when accessing
certain menus via Ethernet.
This section explains the steps required to set or change the password from the
control panel.
The password is extremely important to the security of the library. Closely
guard the password.
Note
The password can also be set through a browser.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select
“8.Password”, then press the
[ENTER] button.
Menu
12:34
7.Tape Inventory
8.Password
9.System Down
3
When “Enter Password” appears,
enter the first character of the
current password in the following
manner:
Enter Password
?
• Use the V and v buttons to select
a letter. The prospective letter is
displayed in the “?” field.
• After displaying the prospective
letter, press the [ENTER] button.
“*” will be displayed.
• Press the [CANCEL] button to
erase one “*”.
• If you are setting the password for
the first time, enter “LIB-81A”.
4
When “Enter New Password” appears, enter the new password up to eight
alphanumeric characters and symbols (! @ # $ % ( ) - { } ~ ").
The maximum number of characters that can be set for a password is eight.
You can not enter more than eight characters.
5
6
7
8
Press the [ENTER] button.
Re-enter the new password.
Press the [ENTER] button.
When “[ENTER] to activate”
appears, press the [ENTER] button.
Enter New Password
? ********
? ********
[ENTER] to activate
The password is now set or changed.
The display returns to the menu.
9
Press the [CANCEL] button to return to the status display.
42
Chapter 3 Basic Usage
Basic Settings
This section explains the steps required to configure the warning message
display, bar code, R-MIC and brightness of the LCD panel using the
Configuration Menu on the control panel.
Caution
There exist LIB-81 AIT library models without bar code or R-MIC readers.
Make sure that your library is equipped with a bar code and/or R-MIC reader
before modifying the “Barcode” or “R-MIC” setting. Modifying these settings
when using LIB-81 AIT library models that are not equipped with the
appropriate readers generates errors.
Note
For information about “Date & Time” of the Configuration Menu, refer to
Disabling the Life Warning Display
When the device is shipped from the factory, the life warning is set to display.
This default setting is recommended. (Thus the following setup is unnecessary.)
Change this setting in “Warning” of the Configuration Menu.
Note
The displaying of the life warning can also be set through a browser.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “5.Configuration”, then press the
[ENTER] button.
3
Select “2.Warning”, then press the
[ENTER] button.
Configuration 12:34
1.Date & Time
2.Warning
3.Barcode
4
Use the V and v buttons to select
“YES”, then press the [ENTER]
button.
Warning
Enable YES
The default factory setting is
“YES”.
Select “NO” to not display the warning.
5
6
When “[ENTER] to activate”
appears, press the [ENTER] button.
Warning
Enable YES
[ENTER] to activate
The life warning is now set.
The display returns to the menu.
Press the [CANCEL] button twice to return to the status display.
43
Chapter 3 Basic Usage
Setting the Bar Code
You should only configure “Barcode” of the Configuration Menu so that the bar
code labels affixed to cartridges can be read when your AIT library is equipped
with a bar code reader. Before modifying this setting, make sure that your
LIB-81 AIT library is equipped with a bar code reader.
Caution
When your library is not equipped with a bar code reader, leave this setting to
“NO”. If you change the setting to “YES”, “No barcode reader installed” is
displayed.
When the AIT library is equipped with a bar code reader but you do not want to
use bar codes, leave this setting to “NO”. If you change the setting to “YES”, it
will take longer for the inventory to be completed when the AIT library starts or
a cartridge is set.
Note
The setting of the bar code can also be configured through a browser.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “5.Configuration”, then press the
[ENTER] button.
3
Select “3.Barcode”, then press the
[ENTER] button.
Configuration 12:34
1.Date & Time
2.Warning
3.Barcode
4
Use the V and v buttons to select
“YES”, then press the [ENTER]
button.
Barcode
Enable YES
The default factory setting is “NO”.
Select “YES” to read the bar code.
5
6
When “[ENTER] to activate”
appears, press the [ENTER] button.
Barcode
Enable YES
[ENTER] to activate
When the bar code is read, the
library returns to the menu display.
Press the [CANCEL] button twice to return to the status display.
Setting the R-MIC Function
If you are using a model equipped with an R-MIC reader, only enable “R-MIC”
of the Configuration Menu if you use AIT-5, AIT-4, AIT-3 Ex, or AIT-3
cartridges, or AIT cartridges with R-MIC. Before modifying this setting, make
sure that your LIB-81 AIT library is equipped with an R-MIC reader.
Caution
If your library is not equipped with an R-MIC reader, you are using AIT-2
cartridges without R-MIC, or using AIT-1 cartridges, leave this setting to “NO”.
44
Chapter 3 Basic Usage
If you change this setting to “YES”, it will take longer for the inventory to be
completed when the AIT library starts or when you set a cartridge.
Note
The R-MIC function can also be set through a browser.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “5.Configuration”, then press the
[ENTER] button.
3
Select “4.R-MIC”, then press the
[ENTER] button.
Configuration 12:34
4.R-MIC
5.LCD Contrast
6.Sequential Mode
4
Use the V and v buttons to select
“YES”, then press the [ENTER]
button.
R-MIC
Enable YES
The default factory setting is “NO”.
Select “NO” to not use the R-MIC
function.
5
6
When “[ENTER] to activate”
appears, press the [ENTER] button.
R-MIC
Enable YES
[ENTER] to activate
The R-MIC function is now set.
The display returns to the menu.
Press the [CANCEL] button twice to return to the status display.
Adjusting the Brightness of the LCD Panel
In “LCD Contrast” of the Configuration Menu, adjust the brightness of the LCD
panel.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “5.Configuration”, then press the
[ENTER] button.
3
Select “5.LCD Contrast”, then press
the [ENTER] button.
Configuration 12:34
4.R-MIC
5.LCD Contrast
6.Sequential Mode
4
Press the V and v buttons to adjust
LCD contrast, then press the
[ENTER] button.
LCD Contrast
Pressing the V button darkens the
LCD panel, while pressing the v
button makes it brighter.
45
Chapter 3 Basic Usage
5
6
When “[ENTER] to activate”
appears, press the [ENTER] button.
LCD Contrast
■■■■
[ENTER] to activate
The brightness of the LCD panel is
now set. The display returns to the
menu.
Press the [CANCEL] button twice to return to the status display.
Using the Sequential Mode
Depending on your software, you can elect to activate the sequential mode in
“Sequential Mode” of the Configuration Menu.
By activating the sequential mode, you can use the software to automatically
instruct the library to return an ejected cartridge to its original slot and insert the
next cartridge into the AIT drive. You can also adjust the settings so that if the
library finds no cartridge in the next slot it inserts the next cartridge in the
sequence into the AIT drive. It is also possible to make continuous unloading
settings.
Caution
• You must use customized software to be able to use this function. Under
normal circumstances, do not use the sequential mode.
• You can only make continuous unloading settings when the sequential mode
is active.
1
At the status display, press the [MENU] button for 2 second.
2
3
4
Use the V and v buttons to select
“5. Configuration”, then press the
[ENTER] button.
Configuration 12:34
4.R-MIC
5.LCD Contrast
6.Sequential Mode
Select “6. Sequential Mode”, then
press the [ENTER] button.
Sequential Mode 12:34
Sequential Mode NO
Unload Continue NO
“Sequential Mode” appears.
When the “Sequential Mode” setting blinks, use the V and v buttons to
select “YES”, then press the [ENTER] button.
By default, this is “NO”. If you do not want use the sequential mode, leave
this setting to “NO”.
5
When the “Unload Continue” setting blinks, use the V and v buttons to
select “YES”, then press the [ENTER] button.
By default, this is “NO”. If you do not want use the continuous unloading
function, leave this setting to “NO”.
Note
If you do not set “Sequential Mode” in step 4 to “YES”, you cannot change
the “Unload Continue” setting.
6
When “[ENTER] to activate” appears, press the [ENTER] button.
Press the [CANCEL] button twice to return to the status display.
46
Chapter 3 Basic Usage
Disabling the Buttons on the Front Panel
To prevent accidentally pressing the control buttons, you can disable the buttons
on the front panel. Use a browser to disable the buttons in the Library
Administration Menu.
For details on the Library Administration Menu, refer to Chapter 6, “Library
1
2
Launch a browser, then access the Library Administration Menu.
Click “System Configuration”.
The “Configuration” page appears.
3
4
At “Key Operation”, click “Disable” to select.
Click “Submit”.
The library is configured.
Note
If the library power is turned off, the “Key Operation” setting is returned to
“Enable”.
47
Chapter 3 Basic Usage
Assigned Element Addresses
An element is a physical location where a cartridge can be kept. Applications
use element addresses to differentiate between the elements of the AIT library.
In this library, the element addresses are assigned to the cartridge slots and the
AIT drives in the following manner.
Notes
• Since the element addresses of the library are fixed numbers, they cannot be
reassigned.
• The element addresses of the drive appears as DR on the LCD of the library.
For details about how to use element addresses to manipulate cartridges, see
5
6
4
Cartridge
AIT Drive
7
3
82
8
2
1
Handling the Cartridges
When handling or storing the cartridges, note the following cautions.
Handling
• Do not subject the cartridges to strong vibrations. Do not drop the cartridges.
• When loading a cartridge into the AIT library, the lid of the cartridge opens
up automatically. Do not manually open the lid and touch the interior tape.
• The cartridge is preadjusted at the factory, so do not disassemble it.
• The tab of a cartridge is used to prevent writing to the cartridge by accident.
• If the cartridge does not need to be written, move the tab to write protect it.
• If the AIT library is used in a high-humidity environment or a location that is
subject to wide variations in temperature, condensation may prevent cartridge
read/write operation.
• If the cartridge needs not be written to or read from, do not insert or eject it
too often.
48
Chapter 3 Basic Usage
Storing
• Store cartridges in an appropriate environment.
Store cartridges according to the temperature and other surrounding
conditions written on the package. Also, try to keep the temperature and
humidity of the environment constant. Store cartridges out of the direct sun
rays. Do not store them near heating systems. Never place cartridges on a
dashboard or in the glove compartment of a car.
• Store cartridges where there is little dust.
Eliminate sources of dust. Prohibit eating, drinking and smoking near the
storage location. Also, do not store cartridges near copying machines or
printers that emit toner and paper dust.
• When storing cartridge, set the erase-protection tab so that the data cannot be
over written.
• After removing a cartridge from the library, store it in an appropriate location
as soon as possible.
Avoid, as much as possible, changes of temperature and humidity,
contamination by dust and scratches made by touching the interior tape.
Daily Maintenance
Perform the following periodically.
• Clean the air filter.
If the front panel air filter is clogged with dust, the AIT library may overheat,
resulting in fire or other damage. Periodically clean the air filter. For
information about how to remove the air filter, refer to “Changing the Air
• Change the air filter.
Change the front panel air filter once a year. For information about how to
49
Chapter 3 Basic Usage
Operating the
AIT Library
Chapter
Overview
This chapter explains how to take out, change and move the cartridges, how to
view information about the AIT library, cartridges and errors, and how to test
the hardware.
Using the Cartridges
This section explains steps to take out, change and move the cartridges.
For information about how to prepare and load the cartridges, refer to “Setting
Taking Out the Cartridges
To take out a cartridge set in the AIT library or AIT drives specify the slot with
the element address.
For information about element addresses, refer to “Assigned Element
To take a cartridge out of the AIT library:
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “2.Eject/Insert”, then press the [ENTER]
button.
“Eject/Insert” appears.
3
Select “1.Eject From Library”, then
press the [ENTER] button.
Eject/Insert
12:34
1.Eject From Library
2.Eject From Drive
3.Insert Into Library
50
Chapter 4 Operating the AIT Library
4
Select the cartridge ejection
method, then press the [ENTER]
button.
Eject
1.Single Mode
2.Multiple Mode
12:34
• When you want to specify one
slot and eject its cartridge, select
“1. Single Mode”.
• When you want to eject several
cartridges consecutively, select
“2. Multiple Mode”. In this case,
you only need to specify the first slot.
5
6
Use the V and v buttons to set the
Slot 01
element address of the slot where
the cartridge to be taken out is set,
then press the [ENTER] button.
When “[ENTER] to activate”
appears, press the [ENTER] button.
Slot 01
[ENTER] to activate
The cartridge dock shutter opens.
51
Chapter 4 Operating the AIT Library
7
Remove the cartridge from the slot.
Raise the cartridge about 1 mm and pull it out.
8
If you selected “1. Single Mode” in
step 4, press the [CANCEL] button.
Slot 01
Eject Tape
[CANCEL] to exit
Note
Even if you selected “1. Single
Mode” in step 4, you can remove a
different cartridge by using the V
and v buttons to select the slot
element address, and then pressing
the [ENTER] button. Because you
did not select “2. Multiple Mode” in
step 4, the cartridge dock shutter
closes and reopens. When it does,
you can remove another cartridge as
explained above. If you do so, when
you are done removing cartridges
press the [CANCEL] button and
proceed to step 10.
9
If you selected “2. Multiple Mode” in step 4, perform the following
depending on the number of inserted cartridges.
52
Chapter 4 Operating the AIT Library
Two or more inserted
cartridges
Eject Tape Slot 01
Next Slot 02
The element address of the front
slot appears on the first line. The
element address of the next slot
appears on the second line.
1 Eject the cartridge and press the
[ENTER] button.
[CANCEL] to exit
[ENTER] to next slot
2 The slot moves to the next. Eject
the cartridge in the same manner
and press the [ENTER] button.
When you press the [ENTER]
button, the slot moves to the next.
3 Repeat until all the cartridges are
ejected, and then press the
[CANCEL] button.
Only one inserted cartridge
The element address of the front
slot appears on the first line.
(Nothing appears on the second
line.)
Eject Tape Slot 01
[CANCEL] to exit
1 Eject the cartridge and press the
[CANCEL] button.
Caution
Do not put your fingers in the slot
when it is moving, as this could
result in injuries.
10 When “[ENTER] to activate” appears, press the [ENTER] button.
If you selected “1. Single Mode” in
step 4, the display on the right
appears.
Slot 01
Exit ?
[ENTER] to activate
If you selected “2. Multiple Mode”
in step 4, the display on the right
appears.
Eject Tape Slot 01
Exit ?
[ENTER] to activate
The shutter closes and the
initialization is performed.
Slot 01
Initializing
Caution
Keep your fingers clear of the
shutter when it closes.
11 When the initialization ends, press the [CANCEL] button three times to
return to the status display.
Replacing the Cartridges
When replacing a cartridge, specify the slot using the element address. For
information about element addresses, refer to “Assigned Element Addresses”
53
Chapter 4 Operating the AIT Library
To replace a cartridge set in the AIT library:
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “2.Eject/Insert”, then press the [ENTER]
button.
“Eject/Insert” appears.
3
4
Select “1.Eject From Library”, then
press the [ENTER] button.
Eject/Insert
12:34
1.Eject From Library
2.Eject From Drive
3.Insert Into Library
Select the cartridge ejection
method, then press the [ENTER]
button.
Eject
1.Single Mode
2.Multiple Mode
12:34
• When you want to specify one
slot and eject its cartridge, select
“1. Single Mode”.
• When you want to eject several
cartridges consecutively, select
“2. Multiple Mode”. In this case,
you only need to specify the first slot.
5
6
Use the V and v buttons to set the
Slot 01
element address of the slot where
the cartridge to replace is set, then
press the [ENTER] button.
When “[ENTER] to activate”
appears, press the [ENTER] button.
Slot 01
[ENTER] to activate
The cartridge dock shutter opens.
7
Remove the cartridge from the slot.
54
Chapter 4 Operating the AIT Library
Raise the cartridge about 1 mm and pull it out.
8
If you selected “1. Single Mode” in
step 4, press the [CANCEL] button.
Slot 01
Eject Tape
[CANCEL] to exit
Note
Even if you selected “1. Single
Mode” in step 4, you can remove a
different cartridge by using the V
and v buttons to select the slot
element address, and then pressing
the [ENTER] button. Because you
did not select “2. Multiple Mode” in
step 4, the cartridge dock shutter
closes and reopens. When it does,
you can remove another cartridge as
explained above. If you do so, when
you are done removing cartridges
press the [CANCEL] button and
proceed to step 10.
9
If you selected “2. Multiple Mode” in step 4, perform the following
depending on the number of inserted cartridges.
Two or more inserted
cartridges
Eject Tape Slot 01
Next Slot 02
The element address of the front
slot appears on the first line. The
element address of the next slot
appears on the second line.
1 Eject the cartridge and press the
[ENTER] button.
[CANCEL] to exit
[ENTER] to next slot
2 The slot moves to the next. Eject
the cartridge in the same manner
and press the [ENTER] button.
When you press the [ENTER]
button, the slot moves to the next.
3 Repeat until all the cartridges are
ejected, and then press the
[CANCEL] button.
55
Chapter 4 Operating the AIT Library
Only one inserted cartridge
The element address of the front
slot appears on the first line.
(Nothing appears on the second
line.)
Eject Tape Slot 01
[CANCEL] to exit
1 Eject the cartridge and press the
[CANCEL] button.
Caution
Do not put your fingers in the slot
when it is moving, as this could
result in injuries.
10 When “[ENTER] to activate” appears, press the [ENTER] button.
If you selected “1. Single Mode” in
step 4, the display on the right
appears.
Slot 01
Exit ?
[ENTER] to activate
If you selected “2. Multiple Mode”
in step 4, the display on the right
appears.
Eject Tape Slot 01
Exit ?
[ENTER] to activate
The shutter closes and the
initialization is performed.
Slot 01
Initializing
Caution
Keep your fingers clear of the
shutter when it closes.
11 When the initialization ends, press the [CANCEL] button to return to
“Eject/Insert” display.
12 Select “3.Insert Into Library”, then
Eject/Insert
12:34
press the [ENTER] button.
1.Eject From Library
2.Eject From Drive
3.Insert Into Library
13 Select the cartridge insertion
method, then press the [ENTER]
button.
Insert
1.Single Mode
2.Multiple Mode
12:34
• When you want to specify a slot
and insert cartridge in it, select
“1. Single Mode”.
• When you want to insert several
cartridges consecutively, select
“2. Multiple Mode”. In this case,
you only need to specify the first slot.
14 Use the V and v buttons to set the
Slot 01
element address of the slot where
the cartridge is going to be set, then
press the [ENTER] button.
56
Chapter 4 Operating the AIT Library
15 When “[ENTER] to activate”
Slot 01
appears, press the [ENTER] button.
[ENTER] to activate
The cartridge dock shutter opens.
16 Insert the cartridge into the slot.
Be sure to insert it all the way.
17 If you selected “1. Single Mode” in
step 13, press the [CANCEL]
button.
Slot 01
Insert Tape
[CANCEL] to exit
Note
Even if you selected “1. Single
Mode” in step 13, you can insert a
different cartridge by using the V
and v buttons to select the slot
element address, and then pressing
the [ENTER] button. Because you
did not select “2. Multiple Mode” in
step 13, the cartridge dock shutter
closes and reopens. When it does,
you can insert another cartridge as
explained above. If you do so, when
you are done inserting cartridges
press the [CANCEL] button and
proceed to step 19.
57
Chapter 4 Operating the AIT Library
18 If you selected “2. Multiple Mode” in step 4, perform the following
depending on the number of open slots.
Two or more open slots
Insert Tape Slot 01
The slot moves to the next one.
When it stops, insert another
cartridge and press the [ENTER]
button again. Repeat until all the
cartridges are inserted, then press
the [CANCEL] button.
Next Slot 02
[CANCEL] to exit
[ENTER] to next slot
1 Insert a cartridge and press the
[ENTER] button.
2 The slot moves to the next. Insert
another cartridge in the same
manner and press the [ENTER]
button.
When you press the [ENTER]
button, the slot moves to the next.
3 Repeat until all the cartridges are
inserted, and then press the
[CANCEL] button.
Only one open slot
The element address of the front
slot appears on the first line.
(Nothing appears on the second
line.)
Insert Tape Slot 01
[CANCEL] to exit
1 Insert a cartridge and press the
[CANCEL] button.
Caution
Do not put your fingers in the slot
when it is moving, as this could
result in injuries.
19 When “[ENTER] to activate” appears, press the [ENTER] button.
If you selected “1. Single Mode” in
step 4, the display on the right
appears.
Slot 01
Exit ?
[ENTER] to activate
If you selected “2. Multiple Mode”
in step 4, the display on the right
appears.
Insert Tape Slot 01
Exit ?
[ENTER] to activate
The shutter closes and the
initialization is performed.
Slot 01
Initializing
Caution
Keep your fingers clear of the
shutter when it closes.
20 When the initialization ends, press the [CANCEL] button three times to
return to the menu display.
58
Chapter 4 Operating the AIT Library
Moving the Cartridges
It is possible to move a cartridge from a slot to the AIT drive or vice versa. Set
the cartridge in the slot before performing the procedure below. When moving
a cartridge, specify the slot with the element address. For information about
Notes
• It is not possible to move a cartridge between slots. When you want to set a
cartridge in a different slot, first remove the cartridge, then set it in a different
slot.
• It is not possible to remove a cartridge directly from the AIT drive. Perform
the procedure below, move the cartridge to the desired slot, and then remove
it.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “3.Move Tape”, then press the [ENTER]
button.
3
Use the V and v buttons to set the
Source
DR
element address of the slot that has
the moving source cartridge, then
press the [ENTER] button.
Destination 01
Note
“DR” indicates an AIT drive.
4
5
Use the V and v buttons to set the element address of the destination slot,
then press the [ENTER] button.
When “[ENTER] to activate”
appears, press the [ENTER] button.
Source
DR
Destination 01
[ENTER] to activate
The cartridge moves to a new slot,
and the display returns to the menu.
6
Press the [CANCEL] button to return to the status display.
Viewing Information Related to the AIT Library
Using the Information Menu of the control panel, the following information
related to the AIT library can be viewed:
• Vendor ID
• Product name
• Serial number
• Version
Note
Information related to the AIT library can also be viewed through a browser.
59
Chapter 4 Operating the AIT Library
1
At the status display, press the [MENU] button for two seconds.
“Information” appears.
2
3
Select “1.Information”, then press the [ENTER] button.
Select “1.Library”, then press the
[ENTER] button.
Information
12:34
1.Library
2.Drive
The library information is
displayed.
V/ID SONY
Name LIB-81
S/N 12345678
Version 0100
4
Press the [CANCEL] button three times to return to the status display.
Viewing Cartridge Information
Using the Tape Inventory Menu of the control panel, the following information
related to the cartridges can be viewed:
• Bar code information
When the AIT library is equipped with a bar code reader, you can view the bar
code information about the set cartridges by element addresses.
• R-MIC information
When the AIT library is equipped with an R-MIC reader, you can view the
R-MIC information of set AIT-5, AIT-4, AIT-3 Ex, and AIT-3 cartridges, and
AIT-2 cartridges with R-MIC by element address.
Notes
• The bar code information and R-MIC information can be viewed through a
browser.
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “7.Tape Inventory”, then press the
[ENTER] button.
“Tape Inventory” appears.
3
To view the bar code information,
select “1.Barcode”, then press the
[ENTER] button.
Tape Inventory 12:34
1.Barcode
2.R-MIC
60
Chapter 4 Operating the AIT Library
When the AIT library is equipped
with a bar code reader, the bar code
information is only displayed when
the bar code setting is “YES” or
“Enable”.
01:12345678
02:No Tape
• When a cartridge is not set, “No
Tape” is displayed.
• If a cartridge with no bar code
information is set, nothing is
displayed.
• Press the V button to view the
next elementaddress information,
and press the v button to return to
the previous display.
4
To view the R-MIC information, select “2.R-MIC”, then press the
[ENTER] button.
The R-MIC information is only
displayed if you are using an AIT-3,
01:12345678
AIT-3 Ex, or AIT-4 model and the
R-MIC setting is “YES” or
“Enable”.
02:No Tape
• When a cartridge is not set, “No
Tape” is displayed.
• If a cartridge with no R-MIC
information is set, nothing is
displayed.
• Press the V button to view the
next elementaddress information,
and press the v button to return to the previous display.
5
Press the [CANCEL] button three times to return to the status display.
61
Chapter 4 Operating the AIT Library
Operating the AIT Drive
Chapter
Overview
This chapter explains how to view information related to the AIT drive and how
to clean the AIT Drive.
Viewing Information Related to the AIT Drive
Using the Information Menu of the control panel, the following information
related to the AIT drive can be viewed:
• Vendor ID
• Product name
• Serial number
• Version
Note
Information related to the AIT drives can also be viewed through a browser.
1
2
At the status display, press the [MENU] button for two seconds.
Select “1.Information”, then press the [ENTER] button.
“Information” appears.
3
Select “2.Drive”, then press the
[ENTER] button.
Information
1.Library
2.Drive
12:34
The AIT drive information is
displayed.
V/ID SONY
Name SDX-700C
S/N 12345678
Version 0100
4
Press the [CANCEL] button three times to return to the status display.
62
Chapter 5 Operating the AIT Drive
Cleaning the AIT Drive
When the AIT drive needs to be cleaned, the following message appears on the
LCD panel:
Warning
Cleaning request
12:34
Clean the drive by setting the Cleaning cartridge (sold separately) in the AIT
drive. To set the cleaning cartridge, specify the slot and the AIT drive with an
element address. For information about element addresses, refer to “Assigned
There are four types of cleaning cartridges: the SDX5-CL for use with AIT-5
drives; SDX4-CL or SDX4-CLL for use with AIT-4 drives; SDX3X-CL for use
with AIT-3 Ex drives; and SDX1-CL for use with AIT-3, AIT-2, and AIT-1
drives. Make sure that you use the cleaning cartridge appropriate for your drive.
Note
First set the cleaning cartridge in the AIT library, then move it to the AIT drive.
Check in advance which slot is not occupied. For information about how to
1
2
At the status display, press the [MENU] button for two seconds.
Use the V and v buttons to select “2.Eject/Insert”, then press the [ENTER]
button.
“Eject/Insert” appears.
3
4
5
Select “3.Insert Into Library”, then
press the [ENTER] button.
Eject/Insert
12:34
1.Eject From Library
2.Eject From Drive
3.Insert Into Library
Select “1. Single Mode”, then press
the [ENTER] button.
Insert
1.Single Mode
2.Multiple Mode
12:34
Use the V and v buttons to set the
element address of the slot where
the cleaning cartridge is going to be
set, then press the [ENTER] button.
Slot 01
6
When “[ENTER] to activate”
appears, press the [ENTER] button.
Slot 01
[ENTER] to activate
63
Chapter 5 Operating the AIT Drive
The shutter of the cartridge dock opens.
7
Insert the cleaning cartridge into the slot.
Be sure it insert it all the way.
8
9
Press the [CANCEL] button.
Slot 01
Insert Tape
[CANCEL] to exit
When “[ENTER] to activate”
appears, press the [ENTER] button.
Slot 01
Exit ?
[ENTER] to activate
The shutter closes and the
initialization is performed.
Slot 01
Initializing
Caution
Keep your fingers clear of the
shutter when it closes.
64
Chapter 5 Operating the AIT Drive
10 When the initialization ends, press the [CANCEL] button twice to return to
the menu, select “7.Move Tape”, then press the [ENTER] button.
11 Use the V and v buttons to set the
Source
01
element address of the slot where
the cleaning cartridge is set, then
press the [ENTER] button.
Destination DR
12 Make sure that “DR” is selected, then press the [ENTER] button.
13 When “[ENTER] to activate”
Source
01
appears, press the [ENTER] button.
Destination DR
[ENTER] to activate
The cleaning cartridge moves to the AIT drive, and cleaning begins.
Cleaning takes about 30 seconds. (No message is displayed to indicate that
cleaning is completed. Please wait for about 30 seconds.)
14 When cleaning is finished, use the Move Tape Menu to move the cleaning
cartridge form the AIT drive to the AIT library.
15 Use the “Eject From Library” of the Eject/Insert Menu to take out the
cleaning cartridge.
16 Press the [CANCEL] button three times to return to the status display.
Note
If an error message appears, perform one of the following.
• When “Cleaning Tape at EOM” is displayed, a spent cleaning cartridge is set
in the AIT drive. Replace the spent cleaning cartridge with a new one.
• When “Clean failure” is displayed, cleaning failed. Repeat the cleaning
procedure.
65
Chapter 5 Operating the AIT Drive
Using the Library
Administration Menu
Chapter
Overview
This chapter explains what you can do with the Library Administration Menu,
and how you can operate it. It also explains details about menus. Use the Library
Administration Menu through a browser to manipulate objects and configure
settings related to the system, the network and the SCSI IDs. It can also check
the operation condition and view the AIT library and AIT drive information.
Notes
In order to configure and maintain the library through a browser, browser
software must be installed in the computer. The following operating systems
and browsers are compatible with the library.
Operating systems:
• Microsoft Windows 95, Microsoft Windows 98, Microsoft Windows Me, and
Microsoft Windows 2000
Browsers:
• Microsoft Internet Explorer 5.01 or later
• Netscape Communicator 4.7 or later
Precautions when using the Library Administration Menu
When using the Library Administration Menu, note the following browser
settings.
• If “Enable or disable JavaScript” is not set to “Enable”, the time in “Date &
Time” will not advance.
• If “Do not use the font size (style) specified in the Web page” is set, the
display layout may collapse.
• When the pages are viewed using the “Back” button, the newest information
may not be displayed because this operation displays the screens saved in a
cache of the browser.
• If an incorrect parameter is entered, you may not be able to return display to
the former settings by using the browser's cache function. In that case, return
display to the former setting by using the browser's Back button.
• When using Netscape 6.0, set the font size to “100%” or the display layout
may collapse. If “Always use user fonts” is selected, the display layout may
collapse.
66
Chapter 6 Using the Library Administration Menu
Library Administration Menu
When the Library Administration Menu is accessed using a browser, the
following objects can be accomplished through the browser:
• Configure system-related settings
• Configure network-related settings
• Configure SCSI ID-related settings
• Set or change the password
• Update the firmware
• Check the operation condition
• Check the AIT library
• View the AIT library and AIT drive information
• View logs
Accessing Library Administration Menu
Use the browser to operate the Library Administration Menu.
Note
The Library Administration Menu contains English and Japanese pages.
Clicking
in the upper-right corner of the page allows you to
alternate between the English and Japanese pages.
1
2
Launch a browser on a client computer.
Enter “http://XXX.XXX.XXX.XXX/” in the “Address” or “Location”
field.
For “XXX.XXX.XXX.XXX”, enter the IP address set in the server.
(e.g., 192.168.0.1)
Note
If the IP address assigned by a DHCP server is being used, enter the current
IP address in the “Address” field of the browser. The current IP address can
be checked with “IP Address” of the Network Menu of the control panel.
The top page of the Library Administration Menu appears.
67
Chapter 6 Using the Library Administration Menu
(Example) When using Microsoft Internet Explorer
3
Click the button of the menu to operate.
The page corresponding to the selected menu appears.
(Example) “System Configuration” page
68
Chapter 6 Using the Library Administration Menu
4
To return to the top page, click
.
Note
When accessing the Library Administration Menu, we strongly recommend
that you change the password before configuring the settings. For
information about how to set the password, refer to “Password” (page 75)
Menu Items
The following menus are included in the Library Administration Menu.
Note
The Library Administration Menu contains English and Japanese pages.
Clicking
in the upper-right corner of the page allows you to
alternate between the English and Japanese pages.
• System Configuration Menu
You can operate and configure settings related to the system, the network and
the SCSI IDs.
• Maintenance Menu
You can check the operation condition, the AIT library and upload the
firmware of this library.
• Information Menu
You can view information about the AIT library, the AIT drives and the
cartridges.
The rest of this chapter explains what each menu can do.
System Configuration Menu
In the System Configuration Menu, objects related to the system and network
can be configured, and settings related to the system and network can be
changed.
The following items are in the System Configuration Menu.
• Configuration
System objects such of the date and time, the life warning display, the R-MIC
function, and the bar code can be configured.
• Network
Network related settings can be configured.
• SCSI ID
The SCSI IDs of the AIT library and AIT drives can be set.
• Password
The password can be set or changed.
69
Chapter 6 Using the Library Administration Menu
Configuration
In “Configuration”, such objects of the system as the date and time, the life
warning display and the R-MIC function can be configured.
Note
In “Configuration”, some of the items can be set in the Configuration Menu of
the control panel.
1
Click “System Configuration” on the Library Administration Menu. You
can also directly click “Configuration” which is located below “System
Configuration”.
The “Configuration” page appears.
2
Set the following items.
Date & time
Set the date and time of the AIT library. For date, enter in “year/month/
day” format and for time, enter in “hour:minute:second” format. By
default, this setting is “2001/1/1 12:00:00” (January 1st, 2001, 12 noon).
Set this to the current date and time.
Note
The date and time cannot be updated when the AIT library is off.
Life Warning
Click to select whether or not to display the warning given when a specific
part has been operated more times than the specified number of times. The
warning is displayed on the LCD panel of the library. If “Disable” is
selected, the warning will not be displayed.
70
Chapter 6 Using the Library Administration Menu
Key Operation
Click to select whether or not to enable the buttons (the power standby
switch and control buttons) on the front panel. If “Disable” is selected, the
buttons will not function.
Note
If the library power is turned off, the “Key Operation” setting is returned to
“Enable”.
R-MIC
If you are using a model equipped with an R-MIC reader, set whether to
enable to enable the R-MIC function when using an AIT-5, AIT-4,
AIT-3 Ex, or AIT-3 cartridge, or AIT-2 cartridge with R-MIC. When using
AIT-2 cartridges without R-MIC or AIT-1 cartridges, select “Disable”.
Barcode
When the AIT library is equipped with a bar code reader, set whether or not
to read the bar code affixed to the cartridge. If “Disable” is selected, the bar
code will not be read.
Caution
• When the AIT library is not equipped with a bar code reader, do not
change the setting to “Enable” as this causes an error to be displayed
when the library starts or when a cartridge is set.
• If you selected “Enable” for the R-MIC setting and use cartridges without
R-MIC, or if you selected “Enable” for the bar code setting and use
cartridges without bar code labels, initialization after turning on the
library or using the cartridges becomes unusually long. Make sure that
you use appropriate cartridges and settings.
3
Click “Submit”.
The library is configured.
Network
In “Network”, network-related settings can be configured. After configuring,
the AIT library must be restarted.
Note
The network settings can also be configured with the Network Menu of the
control panel.
1
Click “System Configuration” on the Library Administration Menu, then
click “Network”. You can also directly click “Network” which is located
below “System Configuration”.
The page to enter the password appears.
71
Chapter 6 Using the Library Administration Menu
2
Enter the password, then click “OK”.
Note
Each access to the “Network” requires the password to be entered. For
the password is “LIB-81A”.
3
When the following screen appears, enter “LIB81” for “User Name” and
“SONY” for “Password”, then click “OK”.
Note
This screen appears only when you start you browser and access the
Library Administration Menu. The confirmation performed in this screen
is effective until you close your browser.
72
Chapter 6 Using the Library Administration Menu
The “Network” page appears.
4
Set the following items.
Host Name
Enter the host name up to 63 alphanumeric characters and symbols ( - ).
(However, the AIT library does not support DNS.)
Domain Name
Enter the domain name up to 63 alphanumeric characters and symbols ( - .).
(However, the AIT library does not support DNS.)
DHCP
Click to choose whether or not to use an IP address assigned by the network
DHCP server. The following settings are not required if you click
“Enable”.
IP Address
Enter the IP address.
Subnet Mask
Enter the subnet mask.
Gateway
Enter the default gateway address.
DNS (Primary)
“DNS (Primary)” is not supported.
DNS (Secondary)
“DNS (Secondary)” is not supported.
5
Click “Submit”.
73
Chapter 6 Using the Library Administration Menu
6
When “Reboot now?” appears, click “OK”.
The settings become effective when the library restarts.
After the library has restarted, if the screen displayed by your browser is
not correct, click “Refresh”.
Note
If the IP address assigned by a DHCP server is being used, enter the current
IP address in the “Address” field of the browser, and then click “Submit”.
The current IP address can be checked with “IP Address” of the Network
Menu of the control panel.
SCSI ID
In “SCSI ID”, the SCSI IDs and SCSI parities of the AIT library and AIT drives
can be set. After configuring, the AIT library must be restarted.
Caution
Do not use the same SCSI IDs on a same SCSI bus.
Note
The SCSI IDs and SCSI parities can also be set using the SCSI Menu of the
control panel.
1
Click “System Configuration” on the Library Administration Menu, then
click “SCSI ID”. You can also directly click “SCSI ID” which is located
below “System Configuration”.
The “SCSI ID” page appears.
74
Chapter 6 Using the Library Administration Menu
2
Set the following items.
Library
Enter whether or not to enable SCSI ID and SCSI parity of the AIT library.
Drive
Enter whether or not to enable SCSI ID and SCSI parity of Drive.
3
4
Click “Submit”.
When “Reboot now?” appears, click “OK”.
The settings become effective when the library restarts.
After the library has restarted, if the screen displayed by your browser is
not correct, click “Refresh”.
Password
In “Password”, the password can be set or changed. The password is extremely
important for the security of the library. When accessing the Library
Administration Menu, be sure to change the password before configuring the
settings. Furthermore, closely guard the password.
Notes
• Because the password and control panel password are the same, the password
can also be set using the Password Menu of the control panel.
• The network password and user name are separate, therefore cannot be
changed.
1
Click “System Configuration” on the Library Administration Menu, then
click “Password”. You can also directly click “Password” which is located
below “System Configuration”.
The “Password” page appears.
75
Chapter 6 Using the Library Administration Menu
2
3
In the “Current Password” box, enter the current password.
If you are setting the password for the first time, enter “LIB-81A”.
In the “New Password” box, enter the new password up to eight
alphanumeric characters and symbols (! @ # $ % ( ) - { } ~ ").
4
5
In the next “Confirm New Password” box, re-enter the same password.
Click “Submit”.
A message that indicates the completion of setting is displayed.
Caution
The maximum number of characters that can be set for the password is
eight. It is not possible to input more than eight characters.
Maintenance Menu
In the Maintenance Menu, the condition of the AIT library can be checked, and
the firmware of this library can be updated.
Note
Each access to the Maintenance Menu requires the password to be entered.
Enter “LIB-81A” in the “Password” box, then click “OK”. For information
about the password, refer to “Password” (page 75).
The following items are in the Maintenance Menu.
• Life Count
Displays the number of times a specific part has been operated.
• Error Count
Displays the number of times an operation was tried or an error occurred in a
specific part.
• Sensor
Displays information about the individual sensors, DIP switches and encoder
values.
• History
Logs can be viewed.
• Diagnostic
You can check whether or not the AIT library is functioning normally.
• Firmware Upload
The firmware of the AIT library can be uploaded.
76
Chapter 6 Using the Library Administration Menu
Life Count
In “Life Count”, the number of times a specific part has been operated is
displayed.
1
2
In the Library Administration Menu, click “Maintenance”. You can also
directly click “Life Count”, which is located above “Maintenance”.
Enter the password, then click “OK”.
Note
Each access to the Maintenance Menu requires the password to be entered.
For information about the password, refer to “Password” (page 75).
77
Chapter 6 Using the Library Administration Menu
The “Life Count” page appears.
In the “Life Count” page, the numbers of times the following specific parts
have been operated are displayed.
• Slider
• Picker
• Turn Table
• Shutter
• Fan (During operation)
• Drive
• Boot
• Flash
Error Count
In “Error Count”, the number of times an operation was tried or an error
occurred in a specific part is displayed.
1
In the Library Administration Menu, click “Maintenance”, then click
“Error Count”. You can also directly click “Error Count”, which is located
above “Maintenance”.
Note
Each access to the Maintenance Menu requires the password to be entered.
Enter the password, then click “OK”. For information about the password,
78
Chapter 6 Using the Library Administration Menu
The “Error Count” page appears.
In the “Error Count” page, the number of times an operation was tried or
an error occurred in the following specific parts are displayed.
• Slider
• Picker
• Turn Table
• Shutter
• Fan
• Drive
Sensor
In “Sensor”, information about the individual sensors, DIP switches and
encoder values are displayed.
1
In the Library Administration Menu, click “Maintenance”, then click
“Sensor”. You can also directly click “Sensor”, which is located above
“Maintenance”.
Note
Each access to the Maintenance Menu requires the password to be entered.
Enter the password, then click “OK”. For information about the password,
79
Chapter 6 Using the Library Administration Menu
The “Sensor” page appears.
In the “Sensor” page, information about the following specific parts are
displayed.
Sensor
• Turn Table Ref
• Turn Table Index
• Slider Ref
• Slider Pos
• Picker Open
• Picker Close
• Shutter Open
• Shutter Close
• Tape In (Slot)
• Tape In (Picker)
Switch
• switch01
• switch02
• switch03
• switch04
• switch05
• switch06
• switch07
• switch08
Encoder
• Turn Table
• Slider
80
Chapter 6 Using the Library Administration Menu
History
In “History”, the following logs can be viewed.
• Mechanical log
• SCSI log
• Error log
1
In the Library Administration Menu, click “Maintenance”, then click
“History”. You can also directly click “History”, which is located above
“Maintenance”.
Note
Each access to the Maintenance Menu requires the password to be entered.
Enter the password box, then click “OK”. For information about the
password, refer to “Password” (page 75).
The “History” page appears.
2
Click
of the log you want to view.
Mechanical
Displays the Mechanical log. A maximum of 128 entries are displayed in
this log.
SCSI
Displays the SCSI log. A maximum of 128 entries are displayed in this log.
Error
Displays the Error log. A maximum of 32 entries are displayed in this log.
The selected log page appears.
81
Chapter 6 Using the Library Administration Menu
(Example) When the “Mechanical” page is selected
• Click
• Click
to display the next log, and
to display the previous log.
to return to the [History] page.
Diagnostic
In “Diagnostic”, you can check whether or not the AIT library is functioning
normally.
1
In the Library Administration Menu, click “Maintenance”, then click
“Diagnostic”. You can also directly click “Diagnostic”, which is located
above “Maintenance”.
Note
Each access to the Maintenance Menu requires the password to be entered.
Enter the password, then click “OK”. For information about the password,
82
Chapter 6 Using the Library Administration Menu
The “Diagnostic” page appears.
2
Click “Execute”.
Starts diagnosing the library.
When diagnosing is completed, the result of the diagnosis is displayed on
“Result”.
Firmware Upload
In “Firmware Upload”, the firmware of the AIT library can be uploaded.
Please consult your dealer about uploading firmware.
1
In the Library Administration Menu, click “Maintenance”, then click
“Firmware Upload”. You can also directly click “Firmware Upload”,
which is located above “Maintenance”.
When you access the Maintenance Menu, the page to enter the password
appears.
83
Chapter 6 Using the Library Administration Menu
2
Enter the password, then click “OK” .
Note
Each access to the “Maintenance” requires the password to be entered. For
information about the password, refer to “Password” (page 75).
3
When the following screen appears, enter “LIB81” for “User Name” and
“SONY” for “Password”, then click “OK”.
Note
This screen appears only when you start you browser and access the
Library Administration Menu. The confirmation performed in this screen
is effective until you close your browser.
84
Chapter 6 Using the Library Administration Menu
The “Firmware Upload” page appears.
4
5
In the “File Name” box, enter the file name (in full path) of the firmware.
Also, you can click the “Browse” button to specify the file.
Click “Upload”.
A confirmation message appears.
6
Click “OK”.
Starts to upload the firmware.
When the upload is finished, the AIT library restarts automatically.
85
Chapter 6 Using the Library Administration Menu
7
When the AIT library has restarted, click “Refresh” in your browser, and
then make sure that the Library Administration Menu appears normally.
If the Library Administration Menu appears normally, the upload is
complete.
When the firmware upload is finished, it is recommended to restart the
library.
If the Library Administration Menu does not appear normally, restart the
library again.
Caution
• Do not turn off the power of the AIT library while the firmware is being
updated.
• The Library Administration Menu cannot be operated while the firmware
is being updated.
Information Menu
In the Information Menu, information about the AIT library, the AIT drives and
the cartridges can be viewed.
The following items are in the Information Menu:
• Information
Displays information related to the AIT library and AIT drives.
• Inventory
Displays information related to the cartridges.
Information
In “Information”, the following information related to the AIT library and AIT
drives is displayed:
• Vendor ID
• Product ID
• Revision
• Serial number
Note
Information related to the AIT library and the AIT drives can also be viewed in
the Information Menu of the control panel.
1
In the Library Administration Menu, click “Information”. You can also
directly click “Information”, which is located above “Information”.
86
Chapter 6 Using the Library Administration Menu
The “Information” page appears.
Inventory
In “Inventory”, the following information related to the cartridges is displayed:
• The setting condition of the cartridges
You can find out in which slot or AIT drive the cartridge is set.
• Bar code information
When the AIT library is equipped with a bar code reader, you can view the bar
code information about the set cartridges by slots and AIT drives.
• R-MIC information
For AIT-5, AIT-4, AIT-3 Ex, and AIT-3 cartridges, you can view the R-MIC
information about the set cartridges by slots and AIT drives.
Note
Information related to the cartridges can also be viewed in the Tape Inventory
Menu of the control panel.
1
In the Library Administration Menu, click “Information”, then click
“Inventory”. You can also directly click “Inventory”, which is located
above “Information”.
87
Chapter 6 Using the Library Administration Menu
The “Inventory” page appears.
• For the slots and AIT drives that have cartridges,
is displayed.
• When the AIT library is not equipped with a bar code reader or a
cartridge with no bar code information is set, nothing is displayed.
• If a cartridge with no R-MIC information is set, nothing is displayed.
88
Chapter 6 Using the Library Administration Menu
Appendix
If You Forget the Password
If you forget the password, you will not be able perform configurations and
operations that require the password. If you forget the password, contact the
Service and Support Center.
Changing the Air Filter 1
• Depending on the shape of the front panel, the air filter and method for
changing the air filter may differ.
• Once a year, change the air filter of the AIT library. Contact your dealer if you
wish to buy additional air filters.
Air Filter: Model number ACY-FL81
Note
Make sure to clean the air filter once every three months.
1
2
Prepare a new air filter.
Turn off the AIT library power.
89
Appendix
3
Use something thin like a precision screw driver to press button on the side
of the library.
Button
The end of the air filter is slightly ejected.
4
Insert a fingernail into the side groove and remove the filter.
Groove
5
6
Insert the new air filter.
Push it in until it clicks into place.
Change the other filter using the same steps.
90
Appendix
Changing the Air Filter 2
• Depending on the shape of the front panel, the air filter and method for
changing the air filter may differ.
• Once a year, change the air filter of the AIT library. Contact your dealer if you
wish to buy additional air filters.
Air Filter: Model number ACY-FL81-OB (for Black Bezel)
ACY-FL81-OW (for White Bezel)
Note
Make sure to clean the air filter once every three months.
1
2
3
Prepare a new air filter.
Turn off the AIT library power.
To remove the air filter, put your finger on the rough part of the air filter
port and slide the filter horizontally.
WER
PO
4
5
Insert the new air filter.
Push it in until it clicks into place.
Change the other filter using the same steps.
91
Appendix
Troubleshooting
Before contacting a Sony Service center, please check the following items. If the
problem persists, contact a Sony Service center.
The AIT library does not work.
• Verify that the power switch is turned on.
• Verify that the power cable is connected correctly.
• Verify that the shutter of the cartridge dock is closed.
• Verify that the terminator is attached correctly.
• Verify that the SCSI cable is correctly connected from the AIT library to the
host computer.
• Verify that the power of the host computer is turned on.
• Verify that an error code is displayed on the LCD panel of the AIT library. For
information about error codes, refer to the “Error Code List” (page 98) in this
chapter.
• Verify that 10 seconds after restart the power is turned on.
• After restarting the library, when “Error 07000001” appears, press the
[CANCEL] button twice, then on the “Configuration” menu, set “Barcode” to
“NO”. Restart the library. When the AIT library is not equipped with a bar
code reader and the bar code setting is “YES”, an error appears when the
library starts or a cartridge is set.
• If an error appears when you turn on the power for the first time after installing
the AIT library, verify the rear of the AIT library to make sure that the
transport screw was removed from the Shipping position (upper hole).
• Try disconnecting the network cable, if connected.
The AIT library and the host computer cannot
communicate with each other.
• Verify that the SCSI IDs of the AIT library, AIT drives, and host computer are
• Verify that the SCSI adapter card is correctly installed in the computer.
• Verify that all the connected SCSI devices are LVD devices. The AIT library
is an LVD device. Do not connect an HVD device to the library.
• Verify that all the devices on the SCSI bus are Wide SCSI devices. The AIT
library is a Wide SCSI device. All the devices on the SCSI bus must be Wide
SCSI devices. (Wide-Narrow adapters can also be used.)
• Make the length of the SCSI cable, which connects the host computer and the
device at the end of the SCSI bus, shorter than 10 meters (32 ft. 9.7 in.).
(page 96) in this chapter.
• Verify that the AIT library supports the application software. For guidance on
application software that can be used with the AIT library and on supported
operating systems, contact your dealer.
• Verify that the application software is correctly installed and correctly setup
on the host computer.
92
Appendix
• Verify whether the host computer was turned on less than 10 seconds after
turning on the library. If the host computer is turned on too soon after turning
on the library, the host computer may not detect the SCSI devices. When using
DHCP, wait a least 30 seconds.
• If the “DHCP” setting on the “Network” menu is “YES”, try changing the
Data cannot be written or read even though the
application and the library are working properly.
• Verify that the erase-protection tab of the cartridge is set to writable. t
• Use only Sony’s AIT cartridges. Also check whether the AIT drive supports
the cartridges.
• If a cartridge has been used for a long time or very frequently, replace it with
a new cartridge.
• Verify that the cartridge is not damaged.
The cartridges cannot be taken out.
If you are still unable to take out the cartridge, please contact your dealer for
assistance.
The bar code cannot be read.
• Verify that the bar code label is affixed properly so that the numbers are at the
• Verify that the surface of the bar code label is free from dust and dirt.
Miscellaneous
• Verify the shutter of the cartridge dock is closed tightly.
• When you set or remove a cartridge and “Error 07000001” appears, then on
the “Configuration” menu, set “Barcode” to “NO”. Restart the library. When
the AIT library is not equipped with a bar code reader and the bar code setting
is “YES”, an error appears when a cartridge is set or ejected.
Transporting the AIT Library
If you are transporting the AIT library for any reason, such as moving offices or
repairing the library, make the following preparations:
• Take out all the cartridges set in the AIT library. If the cartridges cannot be
taken out by operating the control buttons, refer to “The cartridges cannot be
cartridges.
93
Appendix
• To turn off the power to the AIT library, perform the shutdown procedure
front power standby switch, press the power switch on the rear of the AIT
library. When you shut down the AIT library from the control panel, the
internal mechanism moves to the appointed position, then the power enters the
standby state.
• Remove all the cables such as the power cable, the SCSI cable, the terminator
and the network cable.
in Chapter 2 in reverse. Be sure to fasten the transport screw.
Hardware Specifications
Hardware
AIT Drive
LIB-81/A5: SDX-1100 series (1)
LIB-81/A4: SDX-900 series (1)
LIB-81/A3X: SDX-800 series (1)
LIB-81/A3: SDX-700 series (1)
LIB-81/A2: SDX-500 series (1)
LIB-81/A1: SDX-400 series (1)
Number of drives that can be installed
One drives
Number of cartridges that can be set
Maximum of 8 volumes
Data transfer rate (sustained, no compression)
LIB-81/A5 models
Cartridge Transfer rate
AIT-5
24 MB/s
24 MB/s
18 MB/s
16 MB/s
AIT-4
AIT-3 Ex
AIT-3
LIB-81/A4 models
Cartridge Transfer rate
AIT-4
24 MB/s
18 MB/s
AIT-3 Ex
LIB-81/A3X models
Cartridge Transfer rate
AIT-3 Ex
AIT-3
18 MB/s
16 MB/s
AIT-2 Turbo 16 MB/s
AIT-2 16 MB/s
AIT-1 Turbo 16 MB/s
AIT-1 11 MB/s
AIT-E Turbo 6 MB/s
94
Appendix
LIB-81/A3 models
Cartridge Transfer rate
AIT-3
AIT-2
AIT-1
12 MB/s
12 MB/s
8 MB/s
LIB-81/A2 models
Cartridge Transfer rate
AIT-2
AIT-1
6 MB/s
4 MB/s
LIB-81/A1 models
Cartridge Transfer rate
AIT-1
4 MB/s
(Transfer rates depend on the operating system of the server to
which the library is connected.)
LCD panel
LED
21 characters × 4 rows
Two lamps
External connectors
SCSI
Ultra 160/m SCSI,
Wide Ultra LVD SCSI-compliant High Density 68 pins (2)
10Base-T/100Base-TX (RJ-45) (1)
D-sub 9 pin (1, unused.)
Ethernet
RS232C
Operating environment
Temperature: 10 ºC to 35 ºC
Humidity: 20% to 80%
(Avoid condensation)
Power
AC240 V to 100 V +10%/-10% (50/60 Hz)
Power consumption
AIT-5 Model
AIT-4 Model
55 W (Max)
55 W (Max)
AIT-3 Ex Model 55 W (Max)
AIT-3 Model
AIT-2 Model
AIT-1 Model
55 W (Max)
50 W (Max)
50 W (Max)
External Dimension
430 (W) × 43 (H) × 660 (D) mm
(16.9 (W) × 1.7 (H) × 26.0 (D) in.)
13.5 kg (29.8 lb.)
Mass
Data Storage Capacity
When using 8 cartridges, 2.6:1 data compression
• AIT-5 246 m cartridge:
• AIT-4 246 m cartridge:
8320 GB of data
4160 GB of data
• AIT-3 Ex 186 m cartridge: 3120 GB of data
• AIT-3 230 m cartridge: 2080 GB of data
• AIT-2 Turbo 186 m cartridge:1660 GB of data
• AIT-2 230 m cartridge:
• AIT-1 230 m cartridge:
1040 GB of data
728 GB of data
95
Appendix
When using 8 cartridges, without compression
• AIT-5 246 m cartridge:
• AIT-4 246 m cartridge:
3200 GB of data
1600 GB of data
• AIT-3 Ex 186 m cartridge: 1200 GB of data
• AIT-3 230 m cartridge: 800 GB of data
• AIT-2 Turbo 186 m cartridge:640 GB of data
• AIT-2 230 m cartridge:
• AIT-1 230 m cartridge:
400 GB of data
280 GB of data
Please note: Due to constant improvements, the specifications and outward
appearance of the AIT library may change without notice.
Optional Accessories (sold separately)
Rack Mounting Kit : Model number ACY-RK81
Bar Code Label : Model number ACY-BL60A
SCSI Cable and Terminator Specifications
SCSI Cable
Use an Wide Ultra LVD SCSI cable that conforms to SCSI-3 specifications.
However, when using a model equipped with the AIT-5, AIT-4, AIT-3 Ex or
AIT-3 drive, use an Ultra 160/m SCSI LVD cable.
SCSI Cable Length
The total allowable length of SCSI cables used in one LVD SCSI bus included
the length of all internal and external cables is 12 meters (39 ft. 4.4 in.). The
length of the AIT library internal cable is 2 meters (78.7 in.).
SCSI Specifications
This section describes common specifications of SCSI components and SCSI
buses.
96
Appendix
About SCSI Components
The SCSI system is composed of the following components.
• Initiator
This is the host computer system used to transfer commands. The system
consists of the application software, the operating system, the device driver,
the SCSI adapter card, etc.
• Bus
By connecting the SCSI cables to the SCSI adapter card, the library and other
devices, a path (or a bus) is created for transferring commands.
• Targets
The AIT library and the AIT drive are peripheral devices (or targets) that
receive commands from the host computer. Up to 16 devices (including the
host computer) can be connected to the Wide SCSI bus. Also, up to 8 devices
can be connected to the Narrow SCSI bus.
About SCSI Bus
When you are setting up the AIT library using a SCSI bus, please note the
following precautions
LVD SCSI
The AIT library is an LVD SCSI device. All SCSI devices connected to the AIT
library on the SCSI bus must be LVD SCSI devices.
Wide SCSI
The interface of the AIT library is Wide SCSI. In order to connect the AIT
library to a Narrow SCSI bus, use a 50-pin to 68-pin LVD SCSI adapter. Also,
make sure every unused data lines are terminated by an adapter.
SCSI ID
Set a unique SCSI ID for each device on a SCSI bus. The host computer uses
these SCSI IDs to differentiate between the devices. Also, the SCSI IDs are used
to prioritize the order of communication when several devices are
communicating with the host computer.
Caution
The SCSI ID of a device has nothing to do with its physical location.
SCSI Bus Termination
If the AIT library is the device connected to the end of the SCSI bus, you must
attach a terminator to the unused SCSI connector to terminate the SCSI bus. The
AIT library can supply electric power to the terminator. For information about
97
Appendix
Error Code List
When an error occurs in the AIT library, an error code appears on the LCD
panel. The following is a list of error codes that are displayed on the LCD panel.
When an error code appears, contact your dealer.
Changer Manager Errors
Error code
01000031
01000032
01000033
Description
An internal error occurred in the library.
An internal error occurred in the library.
Access attempted to a non-existent AIT drive.
The AIT drive may not be connected correctly.
NVRAM Driver Error
Error code
02000001
02000002
Description
An internal error occurred in the library.
Could not read/write NVRAM.
Mechanical Manager Error
(Byte2:Axis, Byte1:Class, Byte0:SubClass)
Error code
Description
03010101
PickerAxis Timeout occurred during Close Sensor Low
Wait.
03010201
PickerAxis Timeout occurred during Open Sensor Low
Wait.
03010901
03010A01
03020101
Picker sensor malfunction.
PickerAxis The tape check sensor is not normal.
SliderAxis
SliderAxis
SliderAxis
SliderAxis
Timeout occurred during Origin Sensor Low
Wait.
03020102*
03020201
03020202
Timeout occurred during Origin Sensor
High Wait.
Timeout occurred during Position Sensor
Low Wait.
Timeout occurred during Position Sensor
High Wait.
03020501*
03020601
03020701
03020801
03050101
SliderAxis
SliderAxis
SliderAxis
SliderAxis
TableAxis
Destination not reached.
Fine tuning not possible.
Cartridge cannot be removed.
Cartridge not properly inserted in the drive.
Timeout occurred during Origin Sensor Low
Wait.
03050102
03050201
03050202
03050401
TableAxis
TableAxis
TableAxis
TableAxis
Timeout occurred during Origin Sensor
High Wait.
Timeout occurred during Position Sensor
Low Wait.
Timeout occurred during Position Sensor
High Wait.
The Position Sensor is not normal.
98
Appendix
Mechanical Manager Error
(Byte2:Axis, Byte1:Class, Byte0:SubClass) (Continued)
Error code
Description
03050402
TableAxis
The Position Sensor is not normal. (Origin
was not detected.)
03050501
03050601
03060101
TableAxis
TableAxis
Destination not reached.
Fine tuning not possible.
ShutterAxis Timeout occurred during Close Sensor High
Wait.
03060201
03060901
ShutterAxis Timeout occurred during Open Sensor High
Wait.
Shutter sensor malfunction.
* Verify that the transport screw was removed from the Shipping position. t
Mechanical Control Errors
Error code
04000002
04000003
04000004
Description
MechaCon Parameter is incorrect.
MechaCon Aborted.
MechaCon More than 8 tape volumes present.
Remove extra cartridges from the library.
04000005
040000A0
040000A1
MechaCon Cannot detect tape.
MechaCon Element address is incorrect.
MechaCon Element address does not exist.
AIT drive Errors:
Error code
06000001
06000002
06000061
Description
The drive status is not normal.
The drive SCSI ID was not set properly.
The drive cannot load the cartridge.
Bar code Errors*:
Error code
07000001
07000002
Description
A communication error occurred in the bar code reader.
A read error occurred in the bar code reader.
R-MIC Error:
Error code
08000001
08000002
08000003
08000004
08000005
Description
Could not receive data from R-MIC.
Transfer failure due to internal parameter error.
Data from R-MIC incorrect.
An R-MIC error occurred.
Internal memory error.
Ethernet Error:
Error code
Description
09000001
An Ethernet error occurred.
99
Appendix
Other Messages
Warning Message
Description
Cleaning Request
The AIT drive needs cleaning. Refer to “Cleaning the AIT
Cleaning Tape at EOM The spent cleaning cartridge is set. Replace the spent
cleaning cartridge with a new one.
Clean failure
Cleaning failed. Repeat the cleaning procedure.
When the following messages appear, perform the prescribed actions.
Warning Message
Description
Drive information
XX
If the XX code is 3x, 4x, 5x, or 72, insert a new AIT data
cartridge into the library after cleaning the drive.*
For details, refer to “Cleaning the AIT Drive” (page 63).
If the XX code is CE, see the explanation below.
If the XX code is a code other than those explained
above, contact your dealer.
Drive information
CE
The cleaning cartridge is exhausted. Replace it with a
new one and clean the drive again.
or
Cleaning Tape at EOM
Please check the
transport screw
The transport screw may still be fastened in place. Refer
* If the message “Drive information F8” appears on the display, the cartridge
being used may not be the correct one. Check the type of cartridge being used.
To remove the loaded cartridge, select “3. Move Tape” in the menu and move
the cartridge from the drive to the library slot. Select “2. Eject/Insert Tape”,
and then “1. Eject from Library” to remove the cartridge.
When the following messages appear, contact your dealer.
Warning Message
Description
Threshold condition
Turn Table
The turn table has operated more than the specified
number of times.
Threshold condition
Slider
The slider has operated more than the specified number
of times.
Threshold condition
Picker
The picker has operated more than the specified number
of times.
Threshold condition
Shutter
The shutter has operated more than the specified number
of times.
Threshold condition
Drive Load
The cartridges have loaded in the drive more than the
specified number of times.
Threshold condition
Fan
The fan has operated more than the specified number of
times.
Fan 1 trouble
Fan 2 trouble
Fan 3 trouble
Fan 1-3 trouble
Fan 1 malfunction.
Fan 2 malfunction.
Fan 3 malfunction.
Fan 1, Fan 2 and Fan 3 malfunction.
100
Appendix
For information about the AIT library, refer to your reseller.
Sony Corporation
|