BayRS Version 13.03
Part No. 305279-C Rev 00
September 1999
4401 Great America Parkway
Santa Clara, CA 95054
BayRS Version 13.03 and Site
Manager Software Version
7.03 Release Notes
Nortel Networks NA Inc. Software License Agreement
NOTICE: Please carefully read this license agreement before copying or using the accompanying software or
installing the hardware unit with pre-enabled software (each of which is referred to as “Software” in this Agreement).
BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF
THIS LICENSE AGREEMENT. THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS
UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE. If you do not accept
these terms and conditions, return the product, unused and in the original shipping container, within 30 days of
purchase to obtain a credit for the full purchase price.
1. License Grant. Nortel Networks NA Inc. (“Nortel Networks”) grants the end user of the Software (“Licensee”) a
personal, nonexclusive, nontransferable license: a) to use the Software either on a single computer or, if applicable, on
a single authorized device identified by host ID, for which it was originally acquired; b) to copy the Software solely
for backup purposes in support of authorized use of the Software; and c) to use and copy the associated user manual
solely in support of authorized use of the Software by Licensee. This license applies to the Software only and does not
extend to Nortel Networks Agent software or other Nortel Networks software products. Nortel Networks Agent
software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel
Networks NA Inc. Software License Agreement that accompanies such software and upon payment by the end user of
the applicable license fees for such software.
2. Restrictions on use; reservation of rights. The Software and user manuals are protected under copyright laws.
Nortel Networks and/or its licensors retain all title and ownership in both the Software and user manuals, including
any revisions made by Nortel Networks or its licensors. The copyright notice must be reproduced and included with
any copy of any portion of the Software or user manuals. Licensee may not modify, translate, decompile, disassemble,
use for any competitive analysis, reverse engineer, distribute, or create derivative works from the Software or user
manuals or any copy, in whole or in part. Except as expressly provided in this Agreement, Licensee may not copy or
transfer the Software or user manuals, in whole or in part. The Software and user manuals embody Nortel Networks’
and its licensors’ confidential and proprietary intellectual property. Licensee shall not sublicense, assign, or otherwise
disclose to any third party the Software, or any information about the operation, design, performance, or
implementation of the Software and user manuals that is confidential to Nortel Networks and its licensors; however,
Licensee may grant permission to its consultants, subcontractors, and agents to use the Software at Licensee’s facility,
provided they have agreed to use the Software only in accordance with the terms of this license.
3. Limited warranty. Nortel Networks warrants each item of Software, as delivered by Nortel Networks and properly
installed and operated on Nortel Networks hardware or other equipment it is originally licensed for, to function
substantially as described in its accompanying user manual during its warranty period, which begins on the date
Software is first shipped to Licensee. If any item of Software fails to so function during its warranty period, as the sole
remedy Nortel Networks will at its discretion provide a suitable fix, patch, or workaround for the problem that may be
included in a future Software release. Nortel Networks further warrants to Licensee that the media on which the
Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days
from the date Software is first shipped to Licensee. Nortel Networks will replace defective media at no charge if it is
returned to Nortel Networks during the warranty period along with proof of the date of shipment. This warranty does
not apply if the media has been damaged as a result of accident, misuse, or abuse. The Licensee assumes all
responsibility for selection of the Software to achieve Licensee’s intended results and for the installation, use, and
results obtained from the Software. Nortel Networks does not warrant a) that the functions contained in the software
will meet the Licensee’s requirements, b) that the Software will operate in the hardware or software combinations that
the Licensee may select, c) that the operation of the Software will be uninterrupted or error free, or d) that all defects
in the operation of the Software will be corrected. Nortel Networks is not obligated to remedy any Software defect that
cannot be reproduced with the latest Software release. These warranties do not apply to the Software if it has been (i)
altered, except by Nortel Networks or in accordance with its instructions; (ii) used in conjunction with another
vendor’s product, resulting in the defect; or (iii) damaged by improper environment, abuse, misuse, accident, or
negligence. THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE
IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Licensee is responsible
305279-C Rev 00
iii
for the security of its own data and information and for maintaining adequate procedures apart from the Software to
reconstruct lost or altered files, data, or programs.
4. Limitation of liability. IN NO EVENT WILL NORTEL NETWORKS OR ITS LICENSORS BE LIABLE FOR
ANY COST OF SUBSTITUTE PROCUREMENT; SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES; OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR
PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE, EVEN
IF NORTEL NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT
SHALL THE LIABILITY OF NORTEL NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT
EXCEED THE PRICE PAID TO NORTEL NETWORKS FOR THE SOFTWARE LICENSE.
5. Government Licensees. This provision applies to all Software and documentation acquired directly or indirectly by
or on behalf of the United States Government. The Software and documentation are commercial products, licensed on
the open market at market prices, and were developed entirely at private expense and without the use of any U.S.
Government funds. The license to the U.S. Government is granted only with restricted rights, and use, duplication, or
disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial
Computer Software––Restricted Rights clause of FAR 52.227-19 and the limitations set out in this license for civilian
agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS
252.227-7013, for agencies of the Department of Defense or their successors, whichever is applicable.
6. Use of Software in the European Community. This provision applies to all Software acquired for use within the
European Community. If Licensee uses the Software within a country in the European Community, the Software
Directive enacted by the Council of European Communities Directive dated 14 May, 1991, will apply to the
examination of the Software to facilitate interoperability. Licensee agrees to notify Nortel Networks of any such
intended examination of the Software and may procure support and assistance from Nortel Networks.
7. Term and termination. This license is effective until terminated; however, all of the restrictions with respect to
Nortel Networks’ copyright in the Software and user manuals will cease being effective at the date of expiration of the
Nortel Networks copyright; those restrictions relating to use and disclosure of Nortel Networks’ confidential
information shall continue in effect. Licensee may terminate this license at any time. The license will automatically
terminate if Licensee fails to comply with any of the terms and conditions of the license. Upon termination for any
reason, Licensee will immediately destroy or return to Nortel Networks the Software, user manuals, and all copies.
Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license.
8. Export and Re-export. Licensee agrees not to export, directly or indirectly, the Software or related technical data
or information without first obtaining any required export licenses or other governmental approvals. Without limiting
the foregoing, Licensee, on behalf of itself and its subsidiaries and affiliates, agrees that it will not, without first
obtaining all export licenses and approvals required by the U.S. Government: (i) export, re-export, transfer, or divert
any such Software or technical data, or any direct product thereof, to any country to which such exports or re-exports
are restricted or embargoed under United States export control laws and regulations, or to any national or resident of
such restricted or embargoed countries; or (ii) provide the Software or related technical data or information to any
military end user or for any military end use, including the design, development, or production of any chemical,
nuclear, or biological weapons.
9. General. If any provision of this Agreement is held to be invalid or unenforceable by a court of competent
jurisdiction, the remainder of the provisions of this Agreement shall remain in full force and effect. This Agreement
will be governed by the laws of the state of California.
Should you have any questions concerning this Agreement, contact Nortel Networks, 4401 Great America Parkway,
P.O. Box 58185, Santa Clara, California 95054-8185.
LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT, UNDERSTANDS IT, AND
AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS. LICENSEE FURTHER AGREES THAT THIS
AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN NORTEL NETWORKS AND
LICENSEE, WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND
COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS
AGREEMENT. NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST NORTEL
NETWORKS UNLESS NORTEL NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT, INCLUDING AN
EXPRESS WAIVER OF THE TERMS OF THIS AGREEMENT.
iv
305279-C Rev 00
Contents
Preface
Hard-Copy Technical Manuals ..........................................................................................vii
How to Get Help ..............................................................................................................viii
Chapter 1 BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
Maintenance Release Methodology ..................................................................................1
Year 2000 Compliance .......................................................................................................2
BayRS Version 13.03 Fixed Anomalies .............................................................................2
Site Manager Software Version 7.03 Fixed Anomalies ....................................................13
305279-C Rev 00
v
Preface
Hard-Copy Technical Manuals
You can print selected technical manuals and release notes free, directly from the
which you need documentation. Then locate the specific category and model or
version for your hardware or software product. Using Adobe Acrobat Reader, you
can open the manuals and release notes, search for the sections you need, and print
them on most standard printers. You can download Acrobat Reader free from the
You can purchase selected documentation sets, CDs, and technical publications
through the collateral catalog. The catalog is located on the World Wide Web at
support.baynetworks.com/catalog.html and is divided into sections arranged
alphabetically:
•
•
•
The “CD ROMs” section lists available CDs.
The “Guides/Books” section lists books on technical topics.
The “Technical Manuals” section lists available printed documentation sets.
305279-C Rev 00
vii
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
How to Get Help
If you purchased a service contract for your Nortel Networks product from a
distributor or authorized reseller, contact the technical support staff for that
distributor or reseller for assistance.
If you purchased a Nortel Networks service program, contact the Nortel Networks
Technical Solutions Center at 800-2LANWAN (800-252-6926), Express Routing
Code 153.
viii
305279-C Rev 00
Chapter 1 BayRS Version 13.03 and
Site Manager Software Version 7.03
Release Notes
This document lists the anomalies (also referred to as bugs, change requests, or
CRs) that have been fixed in Nortel Networks™ BayRS™ Version 13.03 and Site
Manager Software Version 7.03.
Use the BayRS Version 13.00 and Site Manager Software Version 7.00
documentation with BayRS Version 13.03 and Site Manager Software Version
7.03.
Maintenance Release Methodology
BayRS Version 13.03 and Site Manager Software Version 7.03 are Maintenance
Releases.
Maintenance Releases are designated by a change in the second number to the
right of the decimal point. They provide a collection of software bug fixes for the
current Major Release. No new software or hardware features or functionality for
either software or hardware is introduced beyond that already contained in the
current Major Release.
A Maintenance Release will occur approximately each 3 to 4 months after a Major
Release occurs. A Maintenance Release replaces the current Major Release (or the
prior Maintenance Release) and will become the current shipping version of
BayRS. Each Maintenance Release will be a consolidation of the prior bug fixes
made through Revision Releases, and will roll up all such software bug fixes
provided by the recent Revision Releases.
305279-C Rev 00
1-1
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
Year 2000 Compliance
BayRS Version 13.03 and Site Manager Software Version 7.03 are Year 2000
Compliance Certified by Nortel Networks. They have successfully passed Nortel
Networks Test Procedure which tests conformance to the Nortel Networks Year
2000 compliance definition, both of which can be found at the Nortel Networks
BayRS Version 13.03 Fixed Anomalies
Nortel Networks has fixed the following anomalies in BayRS Version 13.03.
==========================================================
SITE MANAGER COMPATIBILITY
==========================================================
BayRS version
is managed by
Site Manager version
13.03 ----------------------------------> 7.03
13.02 ----------------------------------> 7.02
13.01 Revision 2 ----------------------> 7.01 and 7.01 Revision 2
13.02 Revision -----------------------> 7.02
13.03 Revision 1 is Year 2000 Compliance Certified by Nortel Networks. It has
successfully passed Nortel Networks Test Procedure which tests conformance to
Nortel Networks Year 2000 compliance definition, both of which can be found at
==========================================================
CR 29673: ATM
After configuring source route bridging (SRB) and SR spanning tree on an ATM
PVC interface when they are not configured on the adjoining device, an MCP
error occurs on the router.
1-2
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 30952: DLSw
The DLS slot memory statistics show incorrect memory usage figure for the DLS
slot. This condition reflects incorrect statistics and inhibits the establishment of
new connections because the erroneous statistic is used to determine whether DLS
can acquire more memory from the system heap when establishing a connection.
CR 33663: PPP MIB II
UniCast packets are not incrementing the MIB properly for a sync link.
CR 33890: Scheduled Boot
High CPU utilization following scheduled boot is impacting all operations on the
router.
CR 34438: Protocol Priority
When an outbound protocol priority SNA traffic filter is enabled on a sync circuit,
bouncing the circuit can cause the sync interface state to report as down until the
traffic filter is disabled.
CR 35161: X.25
Bouncing X.25 may cause a bus error.
CR 35612: BGP
Memory leaks occur on all slots with BGP configured.
CR 75161: Scheduled Boot
Scheduled boot is not Y2K compliant in that the boot does not work for dates in
the year 2000 if the GMT on the router is non-zero.
CR 76003: ATM
After a physical disconnect on an ATM interface, the ifEntry instance is removed.
CR 80224: IGMP
Watch dog timer expires while sending data packets from a source to its matching
group when MTM static forwarding is configured with the same group and
address.
305279-C Rev 00
1-3
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 82539: PPP
The router fails to establish a Point-to-Point Protocol (PPP) session with the RAD/
WebRanger routers. This problem occurs when remote users attempt to access the
central site.
CR 83167: OSPF
A fault occurs in IP when the route table manager fails to delete an entry from the
routing net pool. This condition occurs when a network interface in a
non-backbone area goes down after having learned an OSPF route that is in the
summary range defined in the backbone area.
CR 85093: IP
When running BaySecure Firewall on an ARN router, the free buffer list becomes
corrupt, causing a bus error when allocating a buffer.
CR 87645: 100BT
Lancast 100bt transceiver fails operating system diagnostics.
CR 88632: Boot Prom
The ARN router experiences intermittent boot failures when it incorrectly enters
into diagnostic mode. ARN boot proms require upgrade to version 1.27.
CR 90108: IPX
RCONSOLE and some Lotus Notes applications do not work when IPX traffic
goes over a DOD hot standby circuit.
CR 90436: ATM
When a PVC is configured with an illegal VCI number, it remains in an init state
and cannot be deleted using the BCC. You can only delete the PVC through the
MIB set.
CR 91128: ATM
Toggling a PVC while it is in an init state causes a fault. The init state occurs when
two PVCs are using the same service class value within the same PVC group.
1-4
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 91925: ATM
Deleting an ATM interface without first deleting the PVC and service record
causes a fault to occur.
CR 92237: ATM
Various MCP and VBM errors occur on an ATM interface during a failure
recovery.
CR 92475: OSPF
When originating a new AS external LSA that is less specific than an existing
LSA, the wrong LSID is used.
92520: X.25
When a configured link is bounced in IPEX, TCP reestablishes the link with
another available IP address. This does not work properly in some environments.
A new global IPEX MIB parameter, wfIpexTcpUseIpAddress, has been added to
allow IPEX to use only the IP address associated with the local TCP port instead
of any IP address on the router.
CR 93483: ATM
Random slot disconnects and tag violations occur on an ASE slot.
CR 93936: IP
An adjacent host does not become active across ATM PVC until it is bounced.
This occurs when IP adjacent hosts are configured for ATM PVC and the address
resolution type for the IP interface is set to ATMARP.
CR 94143: TFTP
Using the Technician Interface to delete TFTP can cause a bus error to occur.
CR 96022: Frame relay
A router configured with frame relay PVCs and hardware compression does not
report BECNs received from the frame relay cloud.
305279-C Rev 00
1-5
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 96189: IP
Routers configured for RIP announce policy filters to advertise only one route
with a particular metric may advertise the route as unreachable. This occurs when
the Networks List of the policy is empty, indicating that the policy should match
all routes in the routing table. It appears that if the first route in the routing table is
unreachable, the network(s) in the Advertise List are also advertised as
unreachable, rather than being advertised with the metric specified in the policy.
CR 96944: Frame relay
The router crashes when multilining frame relay service records together.
CR 97635: SDLC
In a configuration with multiple defined link stations on the secondary interface
where a one-link station definition stops sending RR's/Info, the router will not tear
the connection down if the other link station definitions are sending data.
CR 99023: IP
The router experiences a problem synchronizing static routes between slots when
in ISP mode.
CR 99067: OSPF
Under heavy CPU utilization, the router may fault.
CR 100051: NAT
Attempts to create a static NAT map entry in a dynamic global range are
sometimes unsuccessful.
CR 100263: X.25 PAD
If the X.25 PAD receives a call request without a calling address, the PAD does
not fault and the call gets connected.
CR 100610: IP
A router in ISP Mode with a default route and default route for subnets enabled
fails to forward packets over the default route.
1-6
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 92528: ATM
ILMI Address registration fails with the IBM 8265 switch. This causes the
receiving switch to freeze.
CR 101014: IPX
Disabling split horizon may create a bogus host entry on other routers.
CR 101713: BGP
OSPF/RIP does not import eBGP routes into the routing table if
wfBgpIntraAsIbgpRouting is enabled. A new MIB parameter,
wfBgpIgpInterAction, has been added to control route porting between BGP and
IGP. A value of 1 ports eBGP routes to OSPF, a value of 2 ports eBGP to RIP, and
a value of 3 ports eBGP to both OSPF and RIP.
CR 102106: DLSw
A bus error occurs on the router in DLS when the connection to the backup peer is
closed after the primary peer is lost.
CR 102428: VINES
The router is installing its own VINES NetID as next hop after receiving a redirect
with its own NetID as the gateway, which corrupts the VINES route table.
CR 102477: VINES
When you disable VINES globally on one of two routers with redundant
interfaces, the NetID of the router is not removed from the neighboring routing
table. The neighboring VINES router retains the route and continues to advertise it
as reachable.
CR 102685: VINES
Connectivity may be lost to VINES routers or servers when a VINES router is
bounced in a multipath environment.
CR 102837: Spanning tree
Toggling the spanning tree root interface may cause the blocking interface to
forward STE frames.
305279-C Rev 00
1-7
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 103342: Technician Interface
Running readexe bn.exe on a single-slot ARE BLN can cause a VBM error to
occur if the More option is set to On and there is no session activity for 10
seconds.
CR 103355: X.25
Receipt of a disconnect request in TCP retry mode causes an IPEX gateway bus
error.
CR 103570: DLSw/SDLC
Bus errors occur when you bounce DLSw on SDLC to SDLC pu2.0 point-to-point
setup.
CR 103944: VINES
VINES is sending ping responses with a calculated hop count rather than a max
hop count. This causes packets to be zero-hop dropped on the return whenever
there are multiple equal-cost paths with different hop counts.
CR 104133: DLSw
Resetting the slot on SDLC to SDLC setup with DLSw 2.0 may cause bus errors
to occur.
CR 104366: Flash
Compacting an already compacted 40 MB flash card on a FRE-2, FRE-2_060, or
ARE causes a watchdog error to occur.
CR 104948: ATM
The router inserts multiple entries in the LE_ARP table, which causes watchdogs
when reverifying entries in the LE_ARP table. The router also does not bitswap
MAC addresses before sending out LE_ARPs when reverifying 802.5 clients.
CR 105130: Technician Interface
An unauthorized operator can use the partition create and partition delete
commands, which should be restricted to Manager access only.
1-8
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 105221: Source route bridging
When you dynamically configure source route bridging, attempts to change the
global attribute "Group LAN ID" to a value other than the default are not reflected
in the specifically routed frame.
CR 105280: IPEX
The router can't establish more than 10 sessions simultaneously.
CR 105294: VINES
VINES may go to buffer depletion for an extended period when configured in a
redundant topology with equal-cost routes. This generally occurs when you
disable and reenable multiple VINES routes that share a common segment or
when you reboot multiple routers on a common segment.
CR 105388: DVMRP
New generation ID is not being sent when an interface comes up on a DVMRP
slot.
CR 105418: DVMRP
The routing table can become unsynchronized when an unreachable update is
followed by a reachable update from the next hop router before the original
unreachable state is propagated.
CR 105561: IPX
Connectivity to the host is lost when a host entry still exists in the IPX host table
even though packets can't be forwarded to that host. Connectivity can also be lost
when the host is no longer in the host table and it cannot be added again.
CR 105577: SWSERV
Toggling a primary circuit and a backup circuit causes a bus error to occur.
CR 105663: DVMRP
Outbound cache entry may not be installed under the following conditions:
interface A and interface B are on different slots and A is the inbound interface. A
better route is learned from interface B and the cache entry for interface A is then
lost.
305279-C Rev 00
1-9
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 105609: 100 BT ethernet
When a 100 MB Ethernet interface handles large volumes of transmit and receive
traffic, a bus error can occur.
CR 106010: DVMRP
If the router sends a prune/graft to the wrong neighbor, it may cause data loss and
data duplication.
CR 106017: IP
A continuous stream of TFTP file transfer requests directed at an IP broadcast
address can cause an out of buffer condition to occur.
CR 106061: RIP
Tag violations may occur on all IP slots when you boot a router with RIP
configured.
CR 106170: DVMRP
The neighbor router is incorrectly being placed in the loop neighbor list.
CR 106381: ATM
If the PVC is bounced prior to bouncing the service record, the PVC will not come
back up.
CR 106602: Frame relay
Performance on frame relay over HSSI suffers 50% of line speed with 64-byte
packets.
CR 106781: Learning bridge
When an ARE slot disconnects and resets, bridging performance is degraded until
the bridge is bounced.
CR 106888: OSPF
Using Site Manager to dynamically disable and then enable an OSPF area causes
the configured authentication type to be lost and an adjacency is not formed.
1-10
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 106129: ATM
The router incorrectly determines specific 802.5 MAC addresses as broadcasts
when processing LE_ARP responses. This causes the LEC to restart.
CR 107143: ATM
The router is not responding to LE_ARP destined for it's own MAC address on
802.5 elans. This condition affects performance because the router sends
unnecessary traffic to other LECs and creates congestion on the bus.
CR 107164: Frame relay
Bus errors occur on the FRE processor before it goes into diag mode when you
bring down a frame relay interface with an HSSI card configured with IP. This
occurs whenever the router brings down the frame relay interface after not
receiving the LMI status messages.
CR 107581: BGP
BGP is not advertising and withdrawing correctly when handling two
announcements of the same network to two different peers.
CR 107675: DVMRP
When a non-dominant router becomes the dominant router and subordinate
routers are contained in its loop neighbor list, the newly dominant router will not
graft traffic.
CR 107703: IGMP
Multicast data packets gets duplicated on a DVMRP router where MTM has
outbound cache entry on an inbound circuit.
CR 107811: ATM
A memory leak occurs on the ATM interface after a virtual circuit is repeatedly
brought up and then killed using the Technician Interface.
CR 107938: ATM
The router does not clean up the ATM circuit when a port is dynamically deleted
using Site Manager.
305279-C Rev 00
1-11
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 107941: SWSERV
A dial backup circuit may fail to send a message to PPP requesting the creation of
multilink system when the primary circuit is back up. This condition occurs
intermittently when the sync line is bounced.
CR 108052: IPX
A memory leak can occur when a host is added to or deleted from the host table.
CR 108091: DVMRP
Data can be lost when the router learns a subordinate route from one neighbor
router and receives a poison reverse from another router that resides in its
neighbor list.
CR 108407: IP
Extended traffic filters do not work on an ARE once more than 31 filters have
been added.
CR 108689: DVMRP
The router discards the prune packet if an active prune from the downstream
neighbor already exists. Traffic can also be blocked for a period if the new prune
time value is less than the current prune time value.
CR 108776: DVMRP
A temporary data loss can occur when a prune is sent with an incorrect time value
that is smaller than the current prune time value.
CR 109903: ATM.
The LEC attempts to transmit out a virtual circuit (VC) that has been deleted from
the VC table for the ATM driver. This condition persists until the ATM is reset.
1-12
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
Site Manager Software Version 7.03 Fixed Anomalies
Nortel Networks has fixed the following anomalies in Site Manager Software
Version 7.03.
==========================================================
Site Manager Software Version 7.03 is a post-7.00 revision. This version is
backward compatible and supports the following router software versions:
13.03, 13.02, 13.01, and 13.00
12.03, 12.02, and 12.01
11.03, 11.02, 11.01, and 11.00
====================================================
CR 34895: AOT/BOT
Unsupported WAN protocols (AOT/BOT) appear in the WAN protocol menu
when multilining an FT1 or FE1 circuit with a standard sync port.
CR 35415: X.25
Changes to the IP adjacent host mask on an X.25 interface are not properly
updated on a subnet.
CR 80561: TFTP
Executing large numbers of TFTPs on a PC platform can cause general protection
faults to occur.
CR 91577: Site Manager
There is a compatibility problem with Site Manager on HP/UX 10.20 with the X/
Motif 1.2 Libraries Y2K patch (PHSS_13113, PHSS_14040, and PHSS_16120).
When you use Events -> Load Local Log Files, the message "Log Browser
module completed abnormally (E1701)" incorrectly appears. Also, when you
choose router types in a local file configuration, the window color obscures the
clear display of router types.
305279-C Rev 00
1-13
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 97013: Configuration Manager.
The color mapping at the LAN and WAN Protocols Selection windows in Site
Manager/HP_UX, obscures the display and renders them illegible.
CR 103004: SDLC
Site Manager incorrectly allows SDLC to be configured on the FT1 and FE1
interfaces.
CR 103590: SNMP
Site Manager for Windows 95/98 cache mode causes PCs to hang with a general
protection fault during multiple user connections.
CR 105771: CSMACD
Site Manager does not allow hardware engine type 5431 ESAF-4. This can cause
a common mode termination to occur on CMTS and a looping FTP session.
CR 105902: ASN2
The ASN2 router restarts during a boot because it can't locate the wfHwCfgEntry
entry when it is not the first entry in the hardware.ldb file.
CR 105944: SNMP
Site Manager does not display Technician Interface traps sent by the router in the
Trap Monitor window.
CR 106281: BGP
A request to change the wfBgpIgpInterAction MIB to now control the porting of
BGP routes into an OSPF/RIP domain. This feature was previously controlled by
wfBgpIntraAsIbgpRouting MIB.
CR 106708: Spanning tree
Spanning tree root selection fails with either SRB or LB spanning tree configured
on a null encapsulated ATM PVC service record.
1-14
305279-C Rev 00
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 106866: IP
Attempts to change an IP interface address which has multiple criteria traffic
filters can cause Configuration Manager to fault and terminate with no error
message. This only occurs during attempts to change the first IP instance.
CR 107359: IP
Using the rename option in File Manager to execute a TFTP file transfer from the
router to the local machine can cause a duplication of the files transferred.
CR 107591: Event Manager
Typing a file name without the associated path while saving a log in Event
Manager can cause a core dump to occur.
CR 107606: ATM
Solaris/Site Manager can freeze up when deleting an active ATM circuit.
CR 107816: Report Generator
A core dump can occur in Site Manager when you generate reports in Report
Generator using template files.
CR 108192: SMDS
The Fractional T1 and E1 Logical Line windows display incorrect values at the
following fields when SMDS has been configured as the WAN protocol: Breath of
Life, Service, and WAN Protocol.
CR 108254: Image Builder
Attempts to select a directory by typing the complete path are unsuccessful when
you use the file Open or Save options in Image Builder.
CR 108564: Frame relay
You can not select some protocols when configuring a frame relay interface in Site
Manager on the HP_UX platform.
305279-C Rev 00
1-15
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
CR 108859: IGMP
Invalid non-integer values are being accepted at the Relay Forwarding Timeout
parameter field of the IGMP Global Configuration Window.
CR 109261: Events Manager
Site Manager running on HP/UX platform does not successfully save output to
disk when configuring within Events Manager.
1-16
305279-C Rev 00
|