Atmor new80 User Manual

1
2
3
4
5
7
L
INSTANT  
WATER HEATER  
230V  
N
E
P
8
4
6
7
7
1
2
3
5
L
230V  
N
P
E
6
8
7
7
1
2
3
4
5
L2  
L1 400V  
230V  
N
P
E
1. Multi-pole switch  
2. Terminal block  
3. Thermostat  
5. Switches  
6. LED Light  
7. Heating elements  
8. Pressure switch  
8
6
7
4. Microswitch  
Table 2  
kW loading  
220V 230V 240V  
3.0 3.3 3.6  
3.2 3.5 3.8  
5.0 5.5 6.0  
5.5 6.0 6.6  
7.0 7.7 8.3  
7.3 8.0 8.7  
8.7 9.5 10.3  
Recommended  
cable size  
Recommended  
fuse rating  
Model  
Heat Setting  
New/Lotus - 3.0  
New/Lotus - 3.5  
New/Lotus - 5.0  
New/Lotus - 5.5  
New/Lotus - 7.0  
New/Lotus - 8.0  
New/Lotus - 9.5  
1.0;2.0 or 3.0kW  
1.5;2.0 or 3.5kW  
2.0;3.0 or 5.0kW  
2.5;3.0 or 5.5kW  
3.0;4.0 or 7.0kW  
4.0;4.0 or 8.0kW  
4.5;5.0 or 9.5kW  
2.5mm2  
2.5/4mm2  
4/6mm2  
4/6mm2  
6/10mm2  
6/10mm2  
10mm2  
16amps  
20amps  
25amps  
25-32amps  
40amps  
40amps  
45amps  
• Operating water pressure 0.3-7 BAR (5-100 psi) Water pressure operating power switch  
• Standard 1/2"Ø compression inlet connection Top-left and right cable entry • Bottom-left water entry  
Installation Instructions  
UNIT DIMENSIONS: HEIGHT 185mm WIDTH 300mm DEPTH 110mm  

Yamaha 502 User Manual
Tripp Lite U232 006 User Manual
Trilogy Touch Technology 500 19 54 User Manual
Sony Xperia Z SGP312U1B User Manual
Sony MD Walkman MZ E300 User Manual
Siemens Gigaset 4110 User Manual
Siemens A65 User Manual
Pioneer DEH P6000UB User Manual
Philips Xenium CT9A9QBLK User Manual
Perreaux MID RANGE HORN STAGECRAFT PE8 User Manual