Atomic Clock
with Wireless
Indoor/Outdoor
Thermometer
USER MANUAL
(TE211W)
A PRECISE TIME WITH TEMPERATURE IN
THREE-LINE LCD DISPLAY
View of indoor/outdoor temperature and precise time.
B ALARM BUTTON
Sets an alarm and allows displaying alarm status.
H
A
C CHANNEL BUTTON
Recalls the different remote sensor reading.
D MEMORY BUTTON
CH
1). Recalls maximum or minimum temperature.
2). Clears the memory.
PM
E MODE BUTTON
Changes display modes and confirms settings.
M
D
F UP ( ) BUTTON
1). Increases the setting.
2). Enables atomic clock reception.
3). Activates Time Zone settings.
4.) Activates alarm.
F
E
C
G
B
D
G DOWN ( ) BUTTON
1).Decreases the setting.
2). Activates the remote sensors search.
3). Disables the alarm.
H
SNOOZE/LIGHT BUTTON
1). Activates snooze function and LCD backlight.
2). Stops alarm temporarily.
3
4
F °C/ °F SWITCH
REMOTE SENSOR
FEATURES
Selects the temperature display unit in Celsius or Fahrenheit.
•
Remote temperature transmission to the main unit via
433 MHz signal
BEFORE YOU BEGIN
1. We recommend using alkaline batteries for the main unit
and remote sensor.
•
•
•
•
Case can be wall mounted using built-in hanger
100 feet transmission range without interference
Temperature display selection in Fahrenheit or Celsius
Transmission channel selection
2. Avoid using rechargeable batteries.
3. Insert batteries before first use, matching the polarity as
shown in the battery compartment.
4. Always install batteries in the remote sensor before the
main unit.
5. Press RESET after each battery change, using a paper clip
or similar tool.
E
6. During an initial setup, place the main unit as close as
possible to the remote sensor.
MADE IN CHINA
A
F
D
7. After reception is established (remote temperature will
appear on the receiver’s display), position the remote sensor
and main unit within the effective transmission range of
100 feet.
C
B
NOTE:
TM
1. Avoid setting the time and date on the main unit before the
outdoor temperature is displayed.
THERMO
–
SENSOR
2. The effective operating range may be influenced by the
surrounding building materials and how the receiver and
transmitter are positioned.
3. Position the remote sensor so that it faces the main unit
(receiver), minimizing obstructions such as doors, walls,
and furniture.
A LED INDICATOR
Flashes once when the remote sensor transmits the
reading to the main unit.
4. Though the remote sensor is weather-resistant, it should
be placed away from direct sunlight, rain or snow.
Flashes twice indicating low battery.
B BATTERY COMPARTMENT
BATTERY INSTALLATION
Holds two AA-size batteries.
REMOTE SENSOR
NOTE: Install the batteries; select the channel and type of
temperature (ºC/ºF) before you mount the sensor.
1. Remove the screws from the battery compartment with a
small Phillips screwdriver.
C RESET
Resets all previous settings.
D CHANNEL SWITCH
2. Set the channel. The switch is located in the battery
compartment. Channel 1 is typically selected if
only one remote sensor is being used.
Selects the desired channel.
E WALL-MOUNT RECESSED HOLE
3. If you are using more than one sensor, select a different
channel for each sensor.
Keeps the remote sensor on the wall.
5
6
4. Install two “AA” size alkaline batteries (not included)
matching to the polarities shown in the battery compartment.
5. Replace the battery compartment door and secure the screws.
6. Secure the remote sensor in the desired location.
The unit is in searching mode.
Temperature readings are
securely registered.
BATTERY INSTALLATION:
MAIN UNIT
˚F
No signals.
1. Open the battery compartment door.
2. Install two batteries (UM-3 or “AA” size 1.5V) matching
the polarity as shown in the battery compartment.
3. Replace the battery compartment door.
WWVB RADIO CONTROLLED TIME
The NIST (National Institute of Standards and Technology)
radio station is located in Ft. Collins Colorado. It transmits
an exact time signal continuously throughout the continental
United States at 60 KHz frequency. The Atomic Clock
can receive this WWVB signal through its internal antenna
from up to 2,000 miles away. Due to the nature of the Earth’s
ionosphere, reception can be limited during the daylight hours.
The radio controlled clock will search for an alternate station
that receives its signal from the NIST Atomic clock in Boulder,
Colorado.
LOW BATTERY WARNING
A low-battery indicator [
] will appear on the indoor or
remote temperature reading line of the main unit warning that
the corresponding batteries need replacement..
GETTING STARTED
After batteries are installed, remote sensors will transmit
temperature readings at 45 second intervals. The main unit
may take up to 2 (two) minutes to receive the initial readings.
Upon successful reception, remote temperature will be
displayed. Then the main unit will automatically update
readings at 45-second intervals.
The WWVB tower icon on the main unit’s display will flash
indicating radio signal reception from the WWVB station.
If the tower icon is not fully lit, or if the time is not set
automatically, please consider the following:
If no signals are received from the remote sensor(s) within
(2) two minutes, dashes “
” will be displayed.
*
During night-time hours, atmospheric disturbances are
typically less severe and reception may improve.
A single daily reception is sufficient enough to keep
the accuracy reading within 1 second.
Press and hold [ ] button on the main unit for 2 seconds
to initiate another signal search.
CHECKING REMOTE AND INDOOR TEMPERATURES
The wave icon on the main unit's display located near the
remote sensor reading line, indicates a good reception from
the remote sensor. If the temperature goes above or below the
temperature operating range stated in specifications, the
*
Make sure the main unit is positioned at 8 feet minimum
distance from any interference source such as a TV,
computer monitor, microwave, etc. The successful reception
of the atomic time signal depends on the positioning and
location of the clock. Always place the main unit by the
window for better reception.
display will show dashes “
”.
READING THE KINETIC WAVE DISPLAY
The kinetic wave display shows the main unit (receiver)
signal reception strength.
*
Within concrete wall rooms such as basements or office
buildings, the received signal may be weakened.
Always place the unit near the window.
7
8
MAXIMUM AND MINIMUM TEMPERATURE
The maximum and minimum record of the indoor and remote
temperature will be automatically stored in the memory of the
main unit (receiver). Main unit will display the minimum,
maximum and the current reading upon each press of
MEMORY button. The unit will return to the current
temperature display in 15 seconds. To clear the memory,
press and hold "MEM" for 3 seconds and all stored readings
will be erased.
If everything listed above is in order and there is no reception
anyway, please perform the following steps:
1. Bring main unit and remote sensor close together.
2. Remove 4 small screws from the back of the remote sensor
and open the battery compartment.
3. Remove the batteries from the battery compartment and
reinstall them in the same manner. Remote sensor
LED indicator will flash showing transmission of the signal.
4. Remove the batteries from the main unit and reinstall
them in the same manner.
5. On the main unit select the same channel number as
set on the remote sensor. Outdoor temperature
on the display will show that transmission is being
received successfully .
TEMPERATURE TRENDS
The remote temperature trend indicator shows the trend of
temperatures collected at particular remote sight. There are
three trends will be shown: rising, steady, and falling.
TRANSMISSION COLLISION
TREND
TREND
TREND
Arrow
Signals from other household devices, such as doorbells,
home security systems, and entry controls, may interfere
with this product and may cause temporary reception
failure. This is normal and will not affect the general
performance of the product. The transmission and reception
of temperature readings will resume once the interference
subsides.
indicator
Temperature
Trend
Rising
Steady
Falling
ATOMIC CLOCK
LOST COMMUNICATIONS
1. After the main unit receives temperature readings from the
remote sensor(s), the WWVB time signal receiver will
automatically search for the time signal. This takes
about 5-8 minutes.
If the main unit display for the remote sensor goes blank,
press and hold [ ] button for 2 seconds to begin a new signal
search. If the signal still isn’t received, please make sure that:
1. The remote sensor is in its proper location.
2. The distance between main and remote units is not
over 100 feet.
2. If the radio signal is received, the date and time will be
set automatically, and the [ ] icon will appear.
3. If in 8 minutes the time signal has not been received,
press “MODE” button to set the time manually. Always
place the main unit by the window for better reception.
4. The clock will continue to search for the WWVB time
signal daily for every hour between 1:00 am and 4:30 am.
After the signal has been successfully received, the time
and date will be updated automatically.
3. The path between the units is clear of obstacles. Shorten the
distance between units if necessary.
4. Fresh batteries are installed correctly in both remote and
main units.
Note: When the temperature falls below freezing, the batteries
in outdoor remote sensors may have reduced voltage supply
and a shorter effective range. We recommend to
Use lithium-ion batteries at the temperatures below 32°F
CALENDAR AND CLOCK DISPLAY MODES
Date is displayed in month-date format. Each press of the
MODE button will change the clock display setting between
the time with seconds and time with weekday.
10
9
SETTING CLOCK MANUALLY
TIME ZONE
ALARMS
* Weekday Alarm
1. Press MODE to select the time display with weekday.
The alarm will sound and the alarm icon will flash at the
set time Mondays through Fridays.
2. Select the time zone by pressing and holding the “
button for 3 seconds.
”
3. Keep holding until the desired time zone (Pacific,
* Single Day Alarm
Mountain, Central or Eastern) is selected on the display map.
The alarm will sound and the alarm icon will flash at the
set time, but will not activate on subsequent days.
YEAR, DATE, TIME, TEMPERATURE UNIT
Press and hold MODE for 3 seconds: the year will flash.
* Pre-Alarm
Press “
” or “
” to change the flashing digits.
If an outdoor temperature is 32º F / 0º C or below, the
pre-alarm feature will be activated. The pre-alarm time
interval can be set for 15, 30, 45, 60 or 90 minutes
before the weekday or single alarm time. Press and hold
[ALARM] button for two seconds in Pre-Alarm mode
to set the pre-alarm interval.
After the first value is set, press MODE again.
Continue setting month, day,12 or 24 time format hour,
minutes, language of weekday, and Fahrenheit or Celsius
display. When you’ve set the last value, press MODE for
the last time to return to regular mode.
“
W” (Weekday alarm), “ S” (Single day alarm), and
SETTING THE ALARM
“Pre-AL” (Pre-alarm) icons will indicate which alarm mode
is armed. You can enable or disable an alarm by pressing the
To set any alarm,
1. Press [ALARM] once to display alarm time.
If the alarm is off, “OFF” will be displayed.
2. Press and hold [ALARM] for two seconds.
The hour digit will flash.
[
], [ ] buttons in alarm display mode. Press MODE to
toggle between alarm modes or to return to the default display.
3. Enter the hour using [
] or [
].
PRECAUTIONS
4. Press [ALARM] again. The minute digits will flash.
This product is engineered to give you years of satisfactory
service if handled carefully. Here are a few precautions:
1. Do not immerse the units in water.
5. Enter the minutes using [ ] or [
].
6. Press [ALARM] again to exit.
7. Repeat the same procedure to set the next alarm.
2. Do not clean the units with abrasive or corrosive materials.
They may scratch the plastic parts and corrode the
electronic circuits.
SNOOZE
3. Do not subject the product to excessive force, shock, dust,
temperature, or humidity, which may result in malfunctions,
shorter lifespan, damaged batteries, and damaged parts.
4. Do not tamper with the units' internal components. Doing
so will invalidate the warranty and may cause damage.
These units contain no user-serviceable parts.
When the alarm sounds, press the SNOOZE/LIGHT button
to temporarily stop the alarm. After depressing
SNOOZE/LIGHT button, the alarm sound will resume in
5 minutes. If the alarm is not disabled after that, it will sound
for 4 more minutes and then will stop by itself.
5. Use only fresh batteries. Do not mix new and old batteries.
6. Read the user's manual thoroughly before operating the units.
DISABLING ALARM
Press [ALARM] button on the main unit to disable an alarm.
11
12
SPECIFICATIONS
Temperature Measurement
Main unit
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Indoor Temperature
Proposed operating range
: -5.0°C to +50.0°C /
23.0°F to 158.0°F
: 0.1°C/ 0.2°F
Temperature resolution
Warning: Changes or modification to this unit not expressly
approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
Remote Sensor
Proposed operating range
with alkaline batteries
: -20°C to + 70°C /
-4°F to 158°F
NOTE: This equipment had been tested and found to comply
with the limits for a Class B Digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications.
Proposed operating range
with lithium batteries
: - 38°F to 158°F
( -38.8 C° to 70°C)
: 0.1°C/ 0.2°F
Temperature resolution
RF Transmission Frequency
: 433 MHz
Maximum number of Remote sensors : 3
RF Transmission Range
: Maximum 100 feet
Temperature sampling cycle
: approximately
45 seconds
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one
or more of the following measures:
Calendar and Clock
12/24 hour display in hh : mm format
Date Format: Month – Day format
Day of week: User- selectable in 5 languages
(English, Spanish, French, German, Italian)
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment to an outlet on a circuit different
from that to which the receiver is connected.
4. Consult the dealer or an experienced radio / TV
technician for help.
Dual 4-minute crescendo alarm with snooze
Pre-alarm for ice alert with programmable intervals of
15, 30, 45, 60 and 90 minutes
Blue Backlight
Power
Main unit: 2 AA batteries (not included)
Remote Sensor: 2 AA batteries (not included)
Dimensions
Main unit: 3.54(L) x 4.92(H) x 1.89(D) inches
Remote sensor: 2.38(L) x 4(H) x 1 (D) inch
13
14
DECLARATION OF CONFORMITY
STANDARD WARRANTY INFORMATION
This product is warranted from the manufacturing defects for
one year from date of retail purchase. It does not cover
damages or wear resulting from accident, misuse, abuse,
commercial use, or unauthorized adjustment and repair.
We
Name: Hideki Electronics, Inc.
Address: 7865 SW Mohawk, Tualatin, OR 97062
Telephone No.: 1-503-612-8395
Note that online product registration is required to ensure
valid warranty protection.
declare that the product
To register your product, go to our Company website at:
under the Customer Service menu.
Product No.: TE211W
Product Name: Atomic Clock with Wireless
Indoor/ Outdoor Thermometer
Should you require assistance with this product and its
operation, please contact our
Manufacturer: Hideki Electronics Ltd.
Address: Unit 2304-06, 23/F Riley House, 88 Lei Muk Road,
Kwai Chung, New Territories, Hong Kong
Customer Service Hotline 1(866) 443 3543
Please direct all returns to the place of the original purchase.
Should this not be possible, contact Customer Service Hotline
for assistance and to obtain a Return Merchandise Authorization
(RMA). Returns without a return authorization will be refused.
Please retain your original receipt as you may be asked to
provide a copy for proof of purchase.
is in conformity with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
This device must accept any interference received, including
interference that may cause undesired operation.
Hideki Electronics, Inc. reserves the right to repair or replace
the product at our option.
The information above is not to be used as contact for support
or sales. Please call our customer service hotline
Copyright (2005) Hideki Electronics Inc. All Rights Reserved.
The Honeywell Trademark is used under license from
Honeywell Intellectual Properties Inc.
(refer to the warranty statement) for all inquiries instead.
Honeywell International Inc. makes no representations or
warranties with respect to this product.
15
16
|