E5 HLC6
6 Channel Line Output Converter
FRONT PANEL CONTROLS
ELECTRICAL INSTALLATION
4
3
RCA Connectors
Rear
AMPLIFIER
Speakers
Factory Installed
Radio
5
SUBREMOT
E
SUB
REAR
FRONT
LEVEL
OUTPUT
SUB
REAR
220
ISO
Summed
Separate
Summed
POWER
Separate
SHORT
SIXCHANNELLINEOUTPUTCONVERTER
6
SUB
REAR
OUTPUTVOLUME
FRONT
OUTPUTVOLUME
OUTPUTVOLUME
Front
AMPLIFIER
Speakers
Speaker Level -4 Channel
RCA Connectors
AMPLIFIER
AMPLIFIER
AMPLIFIER
Subwoofers
Factory Installed
Radio
2
SUBREMOT
E
SUB
REAR
FRONT
LEVEL
OUTPUT
SUB
REAR
220
ISO
Summed
Separate
Summed
1
POWER
Separate
SHORT
SIXCHANNELLINEOUTPUTCONVERTER
Rear
Speakers
1
2
Speaker-Level Inputs - Six Speaker Level Inputs
SUB
OUTPUTVOLUME
REAR
FRONT
OUTPUTVOLUME
OUTPUTVOLUME
12V Output Trigger - Gives you a separate 12 volt turn-on lead for external
amplifiers so there is no need to run a separate wire to the front of the car
Sub
Front
Rear
Front
Speakers
3
Ground Isolation Selector - Occasionally alternator noise may appear in a
system because the source unit and amplifier are using different grounding schemes.
To help in this situation, we have provided alternative grounding connections. Make
sure your system is turned OFF before you move these jumpers.
Speaker Level -Signals
4
5
Six Output Channels - Six output channels that can either run independently
or be summed together internally
Channel Summing - The E5 HLC6 internal jumpers allow installer to sum
selected channels into sub channels. This is especially useful for factory-installed
systems with actively crossed-over speaker systems.
6
Level Matching Controls - Allows the user to adjust the outputs on the E5 HLC6
independently to help insure proper level matching throughout the entire system.
-3-
-2-
BLOCK DIAGRAM
SPECIFICATIONS
All specifications are measured at 14.4VDC
>Maximum speaker-level input
>Maximum output level
>Output gain
60 watts @ 4 ohm
9.5 V rms
+/-12dB
>Frequency response
>T otal harmonic distortion
>Input Impedance
10Hz-25kHz
0.01%
180 ohms
PWM switching
200 mA
>Power supply
>Power draw
>Recommended fuse rating
>Remote Trigger Output Current
1 Amp
1 Amp Max