Black Box Computer Accessories LBLPO1A KIT User Manual

December 2009  
LBLP01A-KIT  
VDSL2 Line Power Ethernet Extender Kit  
Extend Ethernet with 100-/60-Mbps downstream/  
upstream connections over copper.  
Bridges 10BASE-T/100BASE-TX Ethernet interface.  
Supports connections up to 1000 feet (304.8 m).  
Select from Fast and Interleaved modes.  
Provides low latency for video/voice/data applications.  
Conforms to Safety-Extra-Low-Voltage (SELV) standard.  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) •  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 •  
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 •  
Customer  
Support  
Information  
FCC and IC RFI Statements  
Federal Communications Commission and Industry Canada Radio Frequency Interference  
Statements  
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict  
accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to  
comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules,  
which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial  
environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own  
expense will be required to take whatever measures may be necessary to correct the interference.  
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to  
operate the equipment.  
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio  
Interference Regulation of Industry Canada.  
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de  
la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.  
Page 3  
VDSL2 Line Power Ethernet Extender Kit  
Normas Oficiales Mexicanas (NOM) Electrical Safety Statement  
INSTRUCCIONES DE SEGURIDAD  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca  
de una alberca, etc..  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación.  
Todo otro servicio deberá ser referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico  
sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes  
que impidan el flujo de aire por los orificios de ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros  
aparatos (incluyendo amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como  
se indique en el aparato.  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados  
sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
724-746-5500 | blackbox.com  
Page 4  
CE Statement  
European Community (CE) Electromagnetic Compatibility Directive  
This equipment has been tested and found to comply with the protection requirements of European Emission  
Standard EN55022/EN61000-3 and the Generic European Immunity Standard EN55024.  
EMC:  
EN55022(2003)/CISPR-2(2002): Class A  
IEC61000-4-2(2001): 4 KV CD, 8 KV AD  
IEC61000-4-3(2002): 3 V/m  
IEC61000-4-4(2001): 1 KV (power line), 0.5 KV (signal line)  
Page 5  
VDSL2 Line Power Ethernet Extender Kit  
1. Specifications .......................................................................................................................................................................................... 7  
2. Overview................................................................................................................................................................................................. 8  
2.1 Introduction ...................................................................................................................................................................................... 8  
2.2 Features............................................................................................................................................................................................ 8  
2.3 Application ....................................................................................................................................................................................... 9  
2.4 What’s Included................................................................................................................................................................................ 9  
2.5 LED Description................................................................................................................................................................................. 9  
2.6 Front and Back Panels ......................................................................................................................................................................10  
3. Installation .............................................................................................................................................................................................11  
4. DIP Switches ..........................................................................................................................................................................................12  
724-746-5500 | blackbox.com  
Page 6  
Chapter 1: Specifications  
1. Specifications  
Data Rate (Maximum): 100/60 Mbps (downstream/upstream)  
Transmission Distance (Maximum): 1000 ft. (304.8 m)  
Flow Control: Half-/full-duplex, autodetects for 10BASE-T/100BASE-TX  
MDI-X: Automatic  
Standards: ITU-T G.993.1/2, SG15Q4 DMT compliant, trellis code with 1024 DMT bins, EMI emissions compliant, FCC Class A,  
CE, IEEE 802.3/IEEE 802.3u Ethernet, 10BASE-T/100BASE-TX, IEEE 802.3af PoE  
Connectors: (1) RJ-11, (1) RJ-45  
Indicators: (9) LEDs: (5) Master: Power, LAN, DSL, Master, PM;  
(4) Slave: Power, LAN, DSL, Slave  
Power Input: Master: 12V DC, 2A;  
Slave: Powered over RJ-11 connection  
Temperature Tolerance: Operating: 32 to 122° F (0 to 50° C)  
Humidity Tolerance: 5 to 95% noncondensing  
Size: Master and Slave: Each unit: 1.1"H x 4.7"W x 3.5"D (2.8 x 12 x 9 cm)  
Page 7  
VDSL2 Line Power Ethernet Extender Kit  
2. Overview  
2.1 Introduction  
The LBLP01A-KIT, a line power pair of VDSL2 (Very high-bit-rate Digital Subscriber Line) Ethernet Extenders, provides broadband  
transmission rates up to 100/60 Mbps downstream/upstream over single-pair copper line for point-to-point Ethernet connectivity.  
It’s a cost-effective line power solution for high-bandwidth applications such as LAN-to-LAN connectivity, video streaming, FTTB,  
and MDU/MTU.  
The LBLP01A-KIT supports transmission distance up to 500 feet (152.4 m) for line power connection at 100/60 Mbps down-  
stream/upstream and up to 1000 feet (304.8 m) at 98/53 Mbps downstream/upstream. The LBLP01A-KIT is always configured as  
one master unit for the central side, and one slave unit for the remote side. The line power is supplied from the master to slave  
unit and conforms to the Safety-Extra-Low-Voltage (SELV) standards. The Ethernet extender kit is also plug-and-play and is easy to  
install.  
The LBLP01A-KIT also conforms to the ITU-T G.993.1 and G.993.2 to meet VDSL/VDSL2 and SG15Q4 DMT for network require-  
ments.  
2.2 Features  
• ITU-T G.993.1, G.993.2 VDSL/VDSL2 and SG15Q4 DMT compliance  
• 100-/60-Mbps downstream/upstream for distances up to 500 feet (152.4 m); 98-/53-Mbps downstream/upstream for  
distances up to 1000 feet (304.8 m)  
• Supports line power with VDSL2 connection  
• Conforms to Safety-Extra-Low-Voltage (SELV) standards  
• RJ-11 connector for DSL interfaces plus RJ-45 connector for Ethernet LAN port  
• 5 LED indicators for master unit, 4 LED indicators for slave unit  
• 4 DIP switches for configuration settings  
• Trellis coding support for up to 1024 discrete multi-tone (DMT) bins  
• Auto MDI-X for 10BASE-T/100BASE-TX Ethernet LAN ports, so you don’t need crossover cable on the Ethernet side  
• Low latency for video/voice/data applications  
• Line surge protection  
• Selectable Fast and Interleaved modes  
• Selectable fixed data rate and fixed SNR margin  
724-746-5500 | blackbox.com  
Page 8  
Chapter 2: Overview  
2.3 Application  
98/53 Mbps up to  
1000 ft. (304.8 m);  
100/60 Mbps up to  
500 ft. (154.2 m)  
VDSL2 Line Power  
Ethernet Extender  
(Master)  
VDSL2 Line Power  
Ethernet Extender  
(Slave)  
Ethernet Switch  
Ethernet Switch  
Line Power  
LAN  
LAN  
Internet  
Figure 2-1. Typical application.  
2.4 What’s Included  
Your package should include the following items. If anything is missing or damaged, please contact Black Box Technical Support  
at 724-746-5500.  
• (1) VDSL2 Line Power Ethernet Extender (Master)  
• (1) VDSL2 Line Power Ethernet Extender (Slave)  
• (1) 12V DC, 2A Power Adapter for VDSL2 PoE Ethernet Extender (Master)  
• This user’s manual on CD-ROM  
2.5 LED Description  
Table 2-1. LED indicators.  
LED  
Color  
Green  
Green  
Function  
POWER  
DSL  
Lights when power is on.  
Lights when VDSL connection has been established.  
Blinks when VDSL is in handshaking mode.  
LAN  
Green  
Lights when Ethernet is connected.  
Blinks when transmitting/receiving data.  
Master/Slave  
PM  
Green  
Green  
Lights when device is in Master or Slave mode.  
Lights when unit is providing line power.  
Off when line power is off.  
Page 9  
VDSL2 Line Power Ethernet Extender Kit  
2.6 Front and Back Panels  
Figures 2-2 and 2-3 show the master unit’s front and back panels and describe their components.  
VDSL Line Power Ethernet Extender—Master  
DIP Switches  
LED Indicators  
Figure 2-2. Master front panel.  
Power Input  
RJ-11 Connector  
RJ-45 Connector  
Figure 2-3. Master rear panel.  
Figures 2-4 and 2-5 show the front and back panels of the slave unit and describe their components.  
VDSL Line Power Ethernet Extender—Slave  
DIP Switches  
LED Indicators  
Figure 2-4. Slave front panel.  
RJ-11 Connector  
RJ-45 Connector  
Figure 2-5. Slave rear panel.  
724-746-5500 | blackbox.com  
Page 10  
Chapter 3: Installation  
3. Installation  
Because the VDSL2 Line Power Ethernet Extender units require no configuration, they can be installed quickly. Follow these steps:  
1. Connect the line interface between the units via RJ-11 cable.  
2. Connect the Ethernet interface using RJ-45 cable.  
3. Connect the power plug to the master unit with the 12V/2A DC power adapter.  
CAUTION: Verify that the AC-DC adapter conforms to your country’s AC power requirement and then insert the power plug.  
NOTE: The interconnecting cables should be acceptable for external use and rated for the proper application considering voltage,  
current, anticipated temperature, flammability, and mechanical serviceability.  
Table 3-1 shows the data rate and transmission distance information via 26 AWG cable at 6 dB without a rate limit.  
Table 3-1. Data rate and transmission distance.  
Downstream  
Upstream  
Distance  
Data Rate (Mbps) Data Rate (Mbps) (feet)  
100  
98  
60  
53  
500  
1000  
Page 11  
VDSL2 Line Power Ethernet Extender Kit  
4. DIP Switches  
Table 4-1 shows the definition of the DIP Switches. Select the switches for optimal configuration.  
Table 4-1. DIP switches and their functions.  
DIP Switches  
SW-1  
SW-2  
SW-3  
SW-4  
Definition  
CO/Remote  
Impulse Noise  
Data Rate  
SNR  
Protection Mode  
Off  
On  
CO  
Interleaved  
Fast  
50/20 Mbps  
Full Rate  
9 dB  
6 dB  
Remote  
VDSL2 Line Power Ethernet  
Extender (Master)  
VDSL2 Line Power Ethernet  
Extender (Slave)  
Figure 4-1. Default value of DIP switches.  
SW-1: CO/Remote  
Off: VDSL2 Line Power Ethernet Extender will act as at the Central Office (Master) side.  
On: VDSL2 Line Power Ethernet Extender will act as at the Customer Premise Equipment (CPE) or Remote side.  
SW-2: Mode for impulse noise protection  
Off: Interleaved mode provides impulse noise protection for any impulse noise with a duration less than 250 µs.  
Interleaved mode has a maximum end-to-end latency of 10 ms. Interleaved mode is the default mode.  
On: Fast mode guarantees a minimum end-to-end latency less than 1 ms.  
SW-3: Rate limit control  
Off: Line rate limited to 50-/20-Mbps.  
On: Provides up to 100-/60-Mbps line rate for distances up to 500 feet (152.4 m).  
SW-4: Signal to Noise Ratio (SNR)  
Off: Higher SNR margin (9 dB) will result in fewer errors with a more stable VDSL link.  
On: Original and normal channel noise protection with 6 dB SNR.  
724-746-5500 | blackbox.com  
Page 12  
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 20 seconds away at 724-746-5500 or blackbox.com.  
About Black Box  
Black Box Network Services is your source for more than 118,000 networking and infrastructure products. You’ll find everything  
from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by  
free, live 24/7 Tech support available in 20 seconds or less.  
© Copyright 2009. All rights reserved.  
724-746-5500 | blackbox.com  

Motorola W510 User Manual
LG Electronics VX 9400 User Manual
La Crosse Technology WT 5120 433 User Manual
Kenwood KDC MP635 User Manual
Intel 80gb Oem Dc S3500 Hd Ssd SSDSC1NB080G401 User Manual
IBM C2B 225 Brick On Sled carrier 128 pin HPC User Manual
IBM 31x User Manual
HP Hewlett Packard HP Microsoft Windows Server 2008 R2 Standard Edition 589256 B21 User Manual
Fujitsu MAY2036RC User Manual
DeLonghi DCU50T Series User Manual