POWERVALUE 11 LI UP
1. Important safety instructions
THIS CHAPTER CONTAINS IMPORTANT SAFETY INSTRUCTIONS. READ IT CAREFULLY
BEFORE STARTING DISASSEMBLING THE UNIT.
1.1. Symbols and warnings
The following symbols are used in this manual, the list below explains each symbol.
THIS SYMBOL IN CONJUNCTION WITH THE SIGNAL WORD “DANGER” INDICATES AN
IMMINENT ELECTRICAL HAZARD.
FAILURE TO OBSERVE THE RELATED SAFETY NOTE MAY CAUSE INJURY, DEATH OR
EQUIPMENT DAMAGE.
THIS SYMBOL IN CONJUNCTION WITH THE SIGNAL WORD “WARNING” INDICATES A
POTENTIALLY DANGEROUS SITUATION.
FAILURE TO OBSERVE MAY CAUSE INJURY, DEATH OR EQUIPMENT DAMAGE.
DO NOT DISPOSE OF WITH ORDINARY TRASH.
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
3/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
1.2. Safety rules
RISK OF ELECTRIC SHOCK:
BEFORE DISASSEMBLING THE UNIT, MAKE SURE THE UPS IS COMPLETELY SWITCHED OFF
AND INTERNAL CAPACITORS HAVE BEEN DISCHARGED BY WAITING AT LEAST 5 MINUTES
AFTER SHUTDOWN THE UNIT.
DANGER
THE UNIT MAY CONTAIN BATTERIES. A BATTERY CAN PRESENT A RISK OF ELECTRICAL
SHOCK AND HIGH SHORT CIRCUIT CURRENT. THE FOLLOWING PRECAUTIONS SHOULD
BE OBSERVED WHEN DISASSEMBLING A UNIT THAT CONTAINS BATTERIES:
A) REMOVE WATCHES, RINGS OR OTHER METAL OBJECTS.
B) USE TOOLS WITH INSULATED HANDLES.
C) WEAR RUBBER GLOVES AND BOOTS.
D) DO NOT LAY TOOLS OR METAL PARTS ON TOP OF BATTERIES.
E) DISCONNECT THE CHARGING SOURCE PRIOR TO CONNECTING OR
DISCONNECTING OF BATTERY TERMINALS.
F) ESTABLISH IF THE BATTERY IS INADVERTENTLY GROUNDED. IF INADVERTENTLY
GROUNDED, REMOVE SOURCE FROM GROUND. CONTACT WITH ANY PART OF A
GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK. THE LIKELIHOOD OF
SUCH SHOCK CAN BE REDUCED IF SUCH GROUNDS ARE REMOVED DURING
INSTALLATION AND MAINTENANCE (APPLICABLE TO EQUIPMENT AND REMOTE
BATTERY SUPPLIES NOT HAVING GROUNDED SUPPLY CIRCUIT. A BATTERY CAN
PRESENT A RISK OF ELECTRICAL SHOCK AND HIGH SHORT CIRCUIT CURRENT.
DANGER
KEEP OUT OF BATTERY POLES WHICH CONTAIN DANGEROUS DC-VOLTAGES CAUSING
FATAL ACCIDENTS.
INAPPROPRIATE MANIPULATIONS OF THE BATTERIES CAN CAUSE LIGHTNING SPARKS.
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
4/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
2. Introduction
2.1. Related to the document
The document contains information for end of life recyclers or treatment facilities in accordance with
the EU Directive 2012/19/EU about waste electrical and electronic equipment (WEEE). Necessary dis-
mantling information are detailed, together with indication of WEEE materials and components requir-
ing selective treatment are located.
Substances of very high concern under Regulation (EC) No 1907/2006* are typically used but not re-
ported in this document: contact ABB to get the latest declaration available.
* Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation,
Authorisation and Restriction of Chemicals (REACH).
2.2. Applicability
This document covers the environmental information of the following products:
Product
Part number
UPS PowerValue 11LI Up 600VA
UPS PowerValue 11LI Up 800VA
UPS PowerValue 11LI Up 1000VA
UPS PowerValue 11LI Up 1500VA
UPS PowerValue 11LI Up 2000VA
4NWP100170R0001
4NWP100171R0001
4NWP100172R0001
4NWP100173R0001
4NWP100174R0001
2.3. Target audience
This document is intended for ABB customers and for professional recyclers. “Professional” refers to the
expertise in implementing selective treatment according local National laws. That includes also the un-
derstanding of immediate or long term safety risks related to exposure to substances.
2.4. Disclaimer
The information presented in this publication does not form part of any quotation or contract, is be-
lieved to be accurate and reliable and may be changed without notice. No liability will be accepted by the
publisher for any consequences of its use. Publication thereof does not convey nor imply any license un-
der patent - or other industrial or intellectual - property rights.
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
5/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
3. Recycling advice
The following table is intended to guide selective treatment and recycling, showing where which sub-
stances of concern are used and where they are located [ref. Directive 2012/19/EU Article 15 and Annex
VII].
Substances of very high concern under Regulation (EC) No 1907/2006(1) are typically used but not re-
ported in this document due to changing nature: contact ABB to get the latest declaration available.
(1) Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).
Substance(s)/Component(s)
Batteries
Printed circuit boards (2)
Where used (potential)
Used as VRLA block(s).
Used.
Plastic containing brominated flame retardants
(BFRs) (2)
- plastic enclosure,
- PVC insulation of internal wiring,
- input/output receptacles,
- bobbin of 50Hz transformer.
Liquid crystal displays (> 100 cm2)
Not used.
Spare electrolyte capacitors (height > 25 mm, diam- Not used.
eter > 25 mm)
Polychlorinated biphenyls containing capacitors
Mercury containing components
Toner cartridges
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Asbestos components which contain asbestos
Cathode ray tubes
CFC, HCFC, HFC, HC
Gas discharge lamps
External electric cables
Components containing refractory ceramic fibres
Components containing radioactive substances
(2) due to assembly complexity and where-used indication, the location of these substances or material will not be indicated along the docu-
ment, unless considered necessary.
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
6/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
Other materials and components, when not indicated above:
High level component
Substance(s)
Original packaging
- Paper,
- Polyethylene foam or film
Fasteners
- Steel, zinc plated
Cables with end terminals
- Copper,
- Brass,
- PVC,
- Nylon,
- PBT
The following electrical components require further separation after removal from UPS. They might con-
tain materials or components requiring selective disposal. Contact the manufacturer to get proper in-
structions:
-
-
50Hz Transformer;
fan.
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
7/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
4. Dismantling and recycling instructions
RISK OF ELECTRIC SHOCK:
- CAPACITORS AND OTHER UPS COMPONENTS MAY STORE NON-LETHAL ENERGY FOR
LONG TIME: HANDLE EVERY CONDUCTIVE PART WITH CARE, AVOIDING SHORT CIRCUIT
CAUSING SPARKING OR ARCING.
- BEFORE DISASSEMBLYING COMPONENTS REQUIRING FURTHER RECYCLING, CONTACT
THE MANUFACTURER TO GET NECESSARY DISPOSAL INFORMATION;
DANGER
This section describes the procedure to follow for disassembly. At the end of each subsections, relevant
WEEE or recycling information are reported.
Remove the UPS from the carton box and make sure it’s powered off.
UPS is delivered with external cables requiring selective disposal.
Figure 4-1: External cables provided
Make sure UPS is powered off the UPS.
VRLA BATTERY BLOCKS CONTAINS HAZARDOUS SUBSTANCES AS:
- INORGANIC LEAD, LEAD COMPOUNDS (Pb – CAS 7439-92-1);
- SULFURIC ACID (CAS 7664-93-9 - CAUSES SEVERE BURNS).
THE CONCENTRATION MAY CHANGE, DEPENDING ON THE MANUFACTURER.
CUTTING OR DAMAGING THE PLASTIC CASE, WILL EXPOSE ENVIROMENT TO FURTHER
HAZARDOUS SUBSTANCES AS LEAD MONOXIDE (CAS 1317-36-8 -HARMFUL BY
WARNING
INHALATION AND IF SWALLOWED).
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
8/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
Steps for 600VA/800VA
1. Loosen the screws that hold the bottom battery panel (A).
2. Remove the bottom battery panel (A).
3. Swipe out the battery (B).
4. Disconnect the battery wires (Error! Reference source not found.).
C
B
C
+
-
B
A
Figure 4-2: Remove the battery (600VA/800VA)
Steps for 1000VA/1500VA/2000VA
1. Loosen the screws that hold the bottom battery panel (A).
2. Remove the bottom battery panel (A).
3. Swipe out the first battery (B2).
4. Remove the two supports (D1 and D2).
5. Swipe out the second battery (B1).
6. Disconnect the batteries wires (C).
UPS
C
C
+
-
UPS
C
B1
D2
C
D1
+
-
A
B2
Figure 4-3: Remove the battery (1000VA/1500VA/2000VA)
STATUS
SECURITY LEVEL
DOCUMENT ID.
REV.
LANG.
PAGE
Approved
Public
4NWD005026
A
EN
9/10
© Copyright 2019 ABB. All rights reserved.
POWERVALUE 11 LI UP
Remove all the screws on the base, opening the cover (Error! Reference source not found.
Fan
Receptacles
Transformer
Printed Circuit Board
Figure 4-4: UPS content