Vita Mix Vita Prep User Manual

F O O D S E R V I C E  
Use and Care Manual  
Read And Save These Instructions  
®
®
®
High-Performance Commercial Blenders  
Includes: BarBoss • Drink Machine  
(Two-Step Timer, Two-Speed, Variable Speed)  
Vita-Prep 3 • Vita-Prep • Vita-Pro  
All Models  
NOTE: Vita-Mix® blenders come with several different control options. Please be sure  
you are following the instructions for your blender model.  
Variable Speed Model  
(Drink Machine, Vita-Prep, Vita-Prep 3, Vita-Pro)  
Timer & Pulse Model  
ON/OFF Power Switch. Up for ON. Down for OFF.  
(BarBoss®)  
HIGH/VARIABLE Switch. HIGH overrides the  
VARIABLE SPEED dial and is the fastest speed  
available. Switch must be set to VARIABLE to use  
the VARIABLE SPEED dial.  
ON/OFF Power Switch. Located on the front of the  
machine below the control panel, the ON/OFF switch  
controls the power to the machine. While plugged in,  
switch to ON to ready the machine for blending.  
Shut OFF the power switch at night or whenever the  
machine will be left unattended.  
VARIABLE SPEED Dial. Allows user to select con-  
tinuously variable motor speeds ranging  
from 1,000 rpm to 24,000 rpm. Active only  
when HIGH/VARIABLE switch is set on  
VARIABLE position.  
TIMER Dial. Allows user to select a number of  
timed settings. All times are total times. Increments  
on timer are approximate seconds. Timer is activated  
only when the power switch is ON. Blender will  
shut off automatically at the end of the pre-set time.  
Two-Speed Model  
(Drink Machine)  
START/STOP TIMER Switch. This is a lighted  
switch. When light is lit, power is ON. Depress  
START/STOP TIMER switch to activate timer  
setting and again to stop a blending cycle.  
ON/OFF Power Switch. Up for ON. Down for OFF.  
HIGH/LOW Switch. Up for HIGH. Down for LOW.  
During operation, you may interrupt timer by  
pressing the START/STOP switch.  
Note on Timers: Stop mid-cycle with  
the START/STOP switch, not the  
ON/OFF switch. If the ON/OFF  
switch was used, wait 30 seconds for  
power to recycle and the timer to  
reset before resuming operation.  
NOTE: Switches may become sticky from use. Unplug the machine and use a wet  
cloth, moistened with water and a mild detergent, to clean around the edges of the  
switch paddles until they function freely. Work the switches back and forth a few times  
to loosen any dried residue under switch. Leaving switches sticky will damage or burn  
out the switches. Clean carefully, using caution not to allow water or other liquids to  
infiltrate the switch. Dry with a soft cotton cloth.  
PULSE Switch. The PULSE switch can be used to  
quickly refresh product in the container by depressing  
the switch and holding down as long as needed.  
The Pulse switch can only be used when the power  
switch is ON.  
Two-Step Timer Model  
(Drink Machine)  
ON/OFF Power Switch. Up for ON. Down for OFF.  
TIMER Dial. Allows user to select a number of  
timed settings. All times are total times. Increments  
on timer are approximate seconds. Timer is activated  
only when the power switch is ON. Blender will  
shut off automatically at the end of the pre-set time.  
Note on Two-Step Timers: Stop mid-  
cycle with the START/STOP switch,  
not the ON/OFF switch. If the ON/OFF  
switch was used, wait 30 seconds for  
power to recycle and the timer to  
reset before resuming operation.  
START/STOP TIMER Switch. This is a lighted  
switch. When light is lit, power is ON. Depress  
START/STOP TIMER switch to activate timer  
setting and again to stop a blending cycle.  
4
5
Two-Piece Lid  
Compact 32 oz. / 0.9 Ltr. Polycarbonate/  
Stackable Container  
Lock  
Unlock  
The two-piece lid is easy to clean and easy  
to put on, take off and seal.  
• The lid has a continuous rim which fits tightly  
inside the container. Push lid into container  
until the side latches are snapped under the  
container lip.  
NOTE: Vita-Mix® lids come in several different styles. Please be sure you are following  
the instructions for your style of lid.  
Figure D  
Two-Piece Lid  
64 oz. / 2.0 Ltr. Polycarbonate Container  
Unlock  
Top view of lid showing Locking Icons.  
Lock  
The two-piece lid is easy to clean and easy  
to put on and take off.  
Position  
Indicator Tab  
To remove lid, pull up gently on the side lid  
latches.  
Press in above  
container tab  
to remove lid  
• The lid has a continuous rim which latches  
inside the container tabs. Push one side of  
the rim under one tab, and with the heel of  
To secure lid plug: Position the lid plug over  
the lid and align either of the position indicator  
tabs with one of the unlocked icons. Press  
the plug into the lid and turn until an indicator  
tab is aligned with a locked icon. (Turn the lid  
over to be sure that plug is properly locked –  
the locking feet must be seated into the lid  
locking notches.) The bottom surface of the  
plug should be snug against the top of the lid.  
• The lid plug can be removed when using the  
accelerator tool or adding ingredients. Turn  
plug to an unlocked icon to remove.  
Figure A  
Rim  
your hands push down, over the opposite tab,  
Top view of lid showing Locking Icons.  
to snap lid into position.  
To remove lid, place hands around the lid,  
pressing thumbs above one of the container  
tabs. Push in and lift off.  
Press in above  
container tab  
to remove lid  
Position  
Indicator Tab  
Side lid  
latches  
To secure lid plug: Position the lid plug over  
the lid and align either of the position indicator  
tabs with an unlocked icon. Press the plug into  
the lid and turn until an indicator tab is aligned  
with one of the locked icons. (Turn the lid over  
to be sure that plug is properly locked – the  
locking feet must be seated into the lid locking  
notches.) The bottom surface of the plug  
should be snug against the top of the lid.  
• The lid plug can be removed when using the  
accelerator tool or adding ingredients. Turn  
plug to an unlocked icon to remove.  
Rim  
Figure E  
Always lock lid when processing hot  
liquids. See warning on page 3.  
Container  
Tab  
Two-Piece Lid  
48 oz. / 1.4 Ltr. Polycarbonate/Stackable  
Container  
The two-piece lid is easy to clean and easy to put  
on, take off and seal.  
Figure B  
Always lock lid when processing hot  
liquids. See warning on page 3.  
• Push lid into container until the side latches are  
snapped under container lip. (See F(1) - F(3).)  
To remove fully latched lid, squeeze tabs  
together on both sides of the container, pull  
upward and off.  
One-Piece Lid (Optional)  
64 oz. / 2.0 Ltr. Polycarbonate Container  
The one-piece lid is easy to put on or take off,  
and to clean, for quick operation.  
Figure F  
• The lid plug can be removed when using the  
accelerator tool. Twist plug to fasten or remove.  
• There is no latch on this lid. Simply hold the  
lid on when starting.  
• Add ingredients through port in top.  
F(1) Unsealed/Unlatched  
F(2) Sealed  
F(3) Fully Latched  
CAUTION: Do not use non-latching one-piece lid  
when processing hot ingredients. Not for use with  
an accelerator tool.  
Figure C  
NOTE: Brand new lids may be a little stiff. This is temporary. To make new lids easier  
to insert and remove, rub a light coating of cooking oil around rim where it seals. Place  
it in container for several minutes, remove and lightly wipe oil off lid.  
Lid resting on container  
using hand to stabilize.  
Lid pushed into container.  
Side latches are not under  
container lip.  
Side latches are snapped  
under container lip.  
6
7
4. Plug the machine into the nearest outlet (if unplugged). Press ON/OFF switch to ON.  
Activate the timer by selecting the desired timer setting on the dial and then depressing  
the START/STOP TIMER switch on the left.  
Two-Speed or Variable Speed Drink Machines,  
®
®
®
Vita-Pro, Vita-Prep and Vita-Prep 3  
4a. If mixture stops circulating, you have likely trapped an air bubble. Either insert the  
accelerator tool through the lid while blending (see page 11), or stop the motor,  
remove the container from the base and stir or scrape the mixture from the sides  
of container into the center using a rubber spatula to press any air bubbles away  
from the blades. Replace the lid and continue blending.  
1. Place liquids and soft foods in container first, solid items and ice last. Although not  
necessary for processing, you may want to cut or break food into smaller pieces for  
precise measuring of ingredients. Thawed or partially thawed fruit is recommended.  
High-speed is recommended for heavy-duty blending.  
2. Set the container on the motor base by aligning it over the centering pad anchored to  
the base. (Motor must be completely stopped before positioning container.)  
Containers are not to be used for hard, dry materials. Avoid running the blender with  
the container empty.  
4b. Due to the blending speed of the machine, processing times are greatly reduced  
over other manufacturers’ machines. Until you become accustomed to the speed,  
watch your mixture carefully to avoid over-blending.  
4c. If stopping the machine mid-cycle, use the START/STOP switch, not the ON/OFF  
switch. If the ON/OFF switch was used, wait 30 seconds for power to recycle and  
the timer to reset before resuming operation.  
3. Always use a lid when blending. If blending hot ingredients, the lid must be securely locked  
in place. When processing hot liquids, DO NOT use a non-latching or one-piece lid.  
4. Plug the machine into the nearest outlet (if unplugged). Select desired speed setting.  
Most foods are blended on HIGH speed. Start heavy or thick foods on the recommended  
speed then switch to HIGH once the mixture begins processing.  
Note: The START/STOP TIMER switch on your machine is lit when power is ON.  
Avoid moveable parts. The machine may stop working if it is overloaded on low  
speed. Reset the machine by turning power off for 30 seconds.  
Warning: If you detect a change in the sound of the machine or if a hard or  
foreign object comes into contact with the blades, do not serve the drink.  
Inspect your blade assembly for loose, nicked or missing parts. If parts are  
loose, missing, or nicked, replace with new blade assembly. (See page 10.)  
5. After the blender has been stopped, wait until the blade comes to a complete stop before  
removing the lid or container from the motor base.  
4a. If mixture stops circulating, you have likely trapped an air bubble. Either insert the  
accelerator tool through the lid while blending (see page 11), or stop the motor,  
remove the container from the base and stir or scrape the mixture from the sides  
of container into the center using a rubber spatula to press any air bubbles away  
from the blades. Replace the lid and continue blending.  
4b. Due to the blending speed of the machine, processing times are greatly reduced  
over other manufacturers’ machines. Until you become accustomed to the speed,  
watch your mixture carefully to avoid over-blending.  
6. To use the PULSE switch to refresh drinks: Make sure the power is ON. With the  
container on the motor base, depress the PULSE switch. Release the switch to stop  
the motor.  
Warning: If you detect a change in the sound of the machine or if a hard or  
foreign object comes into contact with the blades, do not serve the drink/food.  
Inspect your blade assembly for loose, nicked or missing parts. If parts are  
loose, missing or nicked, replace with new blade assembly. (See page 10.)  
6. After the blender has been stopped, wait until the blade comes to a complete stop before  
removing the lid or container from the motor base.  
7. Press the ON/OFF switch to OFF when not in use.  
NOTE: The thermal protector may shut the motor off to protect it from overheating. To  
restart, wait for motor to cool down with the power off (up to 45 minutes). Cooling may be  
quickened by placing the motor base in a cool spot. Unplug first. To speed up the process,  
try circulating the air with a vacuum or fan aimed at the bottom of the base. When the thermal  
protector shuts the motor off, review your processing techniques and your instructions.  
Your recipes may be too thick (add liquid), be processed too long at too low a speed setting,  
or have too much material in them. If the motor seems to be overheating but the thermal  
protector has not turned the machine off, stop the machine and remove the container  
from the base.  
®
Bar Boss and Timer Blender Instructions  
1. Place liquids and soft foods in container first, solid items and ice last. Although not  
necessary for processing, you may want to cut or break food into smaller pieces for  
precise measuring of ingredients. Thawed or partially thawed fruit is recommended.  
High-speed is recommended for heavy-duty blending.  
2. Set the container on the motor base by aligning it over the centering pad anchored to  
the base. (Motor must be completely stopped before positioning container.)  
Containers are not to be used for hard, dry materials. Avoid running the blender with  
the container empty.  
Follow these instructions for the Two-Speed or Variable Speed Drink Machines, Vita-Pro  
and Vita-Preps: Set the dial on HIGH (#10). Turn the machine ON and let the machine run  
for 1 minute. Be careful never to touch any moving part while in use.  
Follow these instructions for the BarBoss and Timer Blenders: Set the timer for 20  
seconds. Turn the machine ON and let the machine run for 20 seconds. Repeat this step 3  
times for a total of 1 minute. Be careful never to touch any moving parts while in use.  
3. Always use a lid when blending. If blending hot ingredients, the lid must be securely locked  
in place. When processing hot liquids, DO NOT use a non-latching or one-piece lid.  
8
9
Blade Assembly  
AcceleratorTool/MotorBase  
Blade Agitator Assembly. The blade assembly  
includes a precision-hardened stainless steel blade  
with enclosed steel ball bearings for maximum durability.  
The accelerator tool prevents an air bubble  
Splash  
from forming while blending and allows for  
Disk  
Step  
the processing of very thick and/or difficult-  
to-process frozen mixtures. While the  
machine is running, use the accelerator  
tool to push ingredients into the blades.  
General Instructions  
The rugged blade assembly literally explodes molecules  
of food and ice in the container, helping every batch to  
homogenize more effectively. The blade does not  
need to be removed for normal cleaning. (Refer to the  
information below to remove or replace.)  
Accelerator Tool use:  
• If thick mixtures stop circulating, you  
may have trapped an air bubble. Insert  
the accelerator tool through the lid and  
stir to release it.  
• Use it only with the lid locked in place  
and lid plug removed.  
Service Contract  
Drive Spline. Mates with drive socket on the motor  
base to turn the blade. NOTE: Removing and replacing  
your container while the coupling is still rotating  
will strip the drive spline “teeth.” (This part is  
NOT removable.)  
NOTE: The accelerator tool has a small  
“step” on it to prevent contact with the  
blades Do not push the accelerator tool “step”  
past the lip of the 32 oz. / 0.9 Ltr. compact  
container. The accelerator tool cannot be  
used with a one-piece non-latching lid.  
• The splash disk (near the top of the  
accelerator tool) and lid prevent the  
accelerator tool from hitting the blades.  
• The container should not be more than  
2/3 full when the accelerator tool is used.  
• Do not use the accelerator tool for  
more than 30 consecutive seconds (to  
avoid overheating).  
Retainer Nut. Must be snug. Order the available  
Retainer Nut Wrench for best results. (Refer to the  
information below to remove or replace.)  
DO NOT force the accelerator tool  
into the 32 oz. / 0.9 Ltr. container.  
Excessive force may cause the  
Never use a blade assembly with loose, damaged or nicked components.  
• Holding the accelerator tool straight  
should allow extra thick ingredients to  
circulate. If not, point the accelerator  
tool toward the side or corner of the  
container.  
accelerator tool to extend too far into the  
container and may cause damage to the  
blades. DO NOT use the older accelerator  
tool that has a straight and smooth surface  
and no “step.” Use of the older model may  
cause damage to the blades.  
Blade Assembly Removal  
CAUTION: Do not remove blades unless absolutely necessary!  
At times, it may be necessary to give your blades additional  
cleaning. An easy-to-use blade assembly removal wrench  
(Item #15596) may be purchased through your Vita-Mix  
Distributor. Never attempt to take the blade assembly itself  
apart. This will void the warranty.  
Turn the container upside down and grip firmly. Insert retainer  
nut wrench in groove of retainer nut and rotate counterclockwise  
to loosen. Then grip blades with a cloth and remove retainer  
nut by hand.  
When processing hot liquids:  
• The two-part latching lid must be securely locked in place. This allows steam  
to escape naturally and will prevent the lid from coming off when the machine  
is turned on.  
• Do not start processing hot liquids on HIGH speed. Always start processing hot  
liquids on LOW speed, then switch to HIGH speed while the machine is running.  
• Use caution with hot liquids. Liquids may spray from under the lid plug  
or escaping steam may cause scalding.  
Retainer Nut Wh  
• Do not process hot ingredients with the Vita-Mix non-latching lid.  
Replacing Blade Assembly  
With the container upside down, grip blades with cloth, insert  
into the container bottom and align with flat sides of container  
opening. Place retainer nut on and hand tighten. Last, carefully  
turn clockwise until secure, using wrench. Do not force. If it is  
not tight enough, you will notice increased container noise.  
Front  
Motor Base  
Power Cord. Your machine is equipped with a 6 ft. / 1.8 m power  
cord. Store the unused portion neatly underneath. Plastic cord  
retainer clips hold the cord securely. They are flexible and will  
return to position after the cord is lifted out. There is no need to  
unscrew the cord retainer clips to let out more cord.  
Retainer Nut Wrench  
in use.  
Back  
10  
11  
Motor Base/Control Panel  
1. Unplug the power cord.  
2. Gently wash the outside surface with a damp soft cotton cloth moistened with a mild  
solution of warm water and nonabrasive detergent or nonabrasive liquid spray  
cleaner. NEVER IMMERSE MOTOR BASE IN WATER OR OTHER LIQUID.  
3. Thoroughly clean switches so that they work freely. They may become sticky. Use a  
wet cloth, moistened with water* and a mild detergent, to clean around the edges of  
the switch paddles until they function freely. Work the switches back and forth a few  
times to loosen any dried residue under switch. Leaving switches sticky will damage  
or burn out the switches. Clean carefully, using caution not to allow water or other  
liquids to infiltrate the switch.  
Care Note  
To ensure that you get the longest possible life from your Vita-Mix machine, we  
recommend the following products, when used as directed by the supplier:  
CLEANING PRODUCTS. . . . . . . . . . . . . . . . . . . . . . . . . SUPPLIER  
Solid Supra, Solid Power,.. . . . . . . . . . . . . . . . . . . . . . . . Ecolab, Inc., St. Paul, MN  
Guardian Acclaim, Solid Guardian Plus, . . . . . . . . . . . . . 800-352-5326  
Solid Super Impact, Solid Insure. . . . . . . . . . . . . . . . . . . www.ecolab.com  
Diverpak. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diversey, Livonia, MI  
Eclipse H2, Liqui-Safe L7 . . . . . . . . . . . . . . . . . . . . . . . . 800-521-8140  
Acclean . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Klenzade Products  
Poly-Brite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Division of Ecolab  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . St. Paul, MN  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612-293-2165  
Glow MB-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wesmar Company, Inc.  
Lustre NC-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seattle, WA  
Lustre Plus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206-783-5344  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . www.wesmar.com  
PSRA 41-D, PSRA 41-E . . . . . . . . . . . . . . . . . . . . . . . . . Anderson Chemical Co.  
Liqui-Ware 1, Liqui-Ware MC . . . . . . . . . . . . . . . . . . . . . Litchfield, MN  
D-Flex, Sur-Met . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800-366-2477  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . www.andersonchemical.com  
RINSE AIDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUPPLIER  
Solid Rinse Dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ecolab, Inc., St. Paul, MN  
Solid Brilliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800-352-5326  
Jet Dry, Rinse Dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . www.ecolab.com  
DESTAINER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUPPLIER  
NuWare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diversey, Livonia, MI  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800-521-8140  
4. Dry with a soft cotton cloth.  
* Be sure to wring excess water out of cloth or sponge when cleaning around the  
controls or any electrical part.  
Lid  
Separate the lid and plug. Wash in warm soapy water. Rinse clean under running  
water and dry. Reassemble before use. (See page 6-7.)  
Container  
For maximum container life, do not wash in dishwasher.  
1. To Clean: Fill container 1/4 full with warm (110˚F/43˚C) water and add a couple  
drops of liquid dishwashing detergent.** Return container to motor base and firmly  
position the two-piece lid. Run machine for 30 seconds. Empty container. Repeat  
this step.  
2. To Rinse: Fill container 3/4 full with warm (110˚F/43˚C) water – do not add soap.  
Return container to motor base and firmly position the two-piece lid. Run machine  
for 30 seconds. Empty container.  
3. If any solid residue remains, remove the blade assembly (see page 10) and wash all  
container parts in warm soapy water. Rinse and drain. Reassemble before next  
step. Do not soak the blade agitator assembly.  
NOTE: Do not use abrasive cleaning agents or concentrated bleach when cleaning.  
Do not use any cleaners containing Quatinary Sanitizers on polycarbonate components  
(i.e., containers). Do not use any of the following cleaning products: automatic  
dishwashing detergents, oven cleaners, steel wool or other abrasive pads.  
ADDITIONAL NOTE: Do not let mixtures, liquids and food products dry in the  
container. Rinse throughout use. Dry product may lock around the blade and  
weaken/tear the bearings seal when restarted. Do not place containers in the freezer.  
Extremely low temperature combined with hot ingredients and/or the immediate rapid  
action of the blade may crack the container. Due to the nature of polycarbonates,  
microwaving and automatic dishwashing are not recommended. Follow the cleaning  
instructions on page 13.  
4. To Sanitize: If all solid residue is gone after step 2 or after completion of step 3,  
fill container 3/4 full with a sanitizing solution mix.*** Return container to motor base  
and firmly position the two-piece lid. Run machine on a high speed for 30 seconds.  
Turn machine off and allow mixture to stand in the container for an additional 1-1/2  
minutes. Pour out bleach mixture.  
5. Return container to motor base and run machine empty for an additional 5 seconds.  
Do not rinse after sanitizing. Allow container to air dry.  
** To prolong polycarbonate container life, Vita-Mix recommends using soaps with a  
low Ph balance, such as a liquid dishwashing detergent (Ivory Liquid®). Due to the  
nature of polycarbonates, automatic dishwashing is not recommended.  
*** Recommended sanitizing solution: 1.5 tsp. / 7.4 ml institutional or household bleach  
in 2 qt. / 2.0 Ltr. water.  
12  
13  
®
®
®
BarBoss and Drink Machines  
Vita-Pro and Vita-Prep  
NOTE: Vita-Mix blenders come in several similar styles. Please be sure you are following  
NOTE: Vita-Mix® blenders come in several similar styles. Please be sure you are  
following the parts list for your blender model.  
Item # Part  
the parts list for your blender model.  
Item # Part  
755  
1192  
1191  
756  
Lid plug for 64 oz. / 2.0 Ltr. polycarbonate container  
Lid only (no plug) for 64 oz. / 2.0 Ltr. polycarbonate container  
Lid assembly for 64 oz. / 2.0 Ltr. polycarbonate container  
64 oz. / 2.0 Ltr. polycarbonate container, ice blade & lid assemblies  
64 oz. / 2.0 Ltr. polycarbonate container only  
Lid plug for 48 oz. / 1.4 Ltr. polycarbonate/stackable container  
Lid only (no plug) for 48 oz. / 1.4 Ltr. polycarbonate/stackable container  
Lid assembly for 48 oz. / 1.4 Ltr. polycarbonate/stackable container  
48 oz. / 1.4 Ltr. polycarbonate/stackable container,  
ice blade & lid assemblies  
755  
1192  
1191  
1195  
758  
1159  
15526  
15507  
15504  
Lid plug for 64 oz. / 2.0 Ltr. polycarbonate container  
Lid only (no plug) for 64 oz. / 2.0 Ltr. polycarbonate container  
Lid assembly for 64 oz. / 2.0 Ltr. polycarbonate container  
64 oz. / 2.0 Ltr. polycarbonate container, wet blade & lid assemblies  
64 oz. / 2.0 Ltr. polycarbonate container only  
Lid plug for 48 oz. / 1.4 Ltr. polycarbonate/stackable container  
Lid only (no plug) for 48 oz. / 1.4 Ltr. polycarbonate/stackable container  
Lid assembly for 48 oz. / 1.4 Ltr. polycarbonate/stackable container  
48 oz. / 1.4 Ltr. polycarbonate/stackable container,  
wet blade & lid assemblies  
758  
1159  
15526  
15507  
15506  
15502  
1151  
836  
48 oz. / 1.4 Ltr. polycarbonate/stackable container only  
Blade agitator assembly (ice blade)  
Heavy-duty retainer nut  
15502  
1152  
836  
48 oz. / 1.4 Ltr. polycarbonate/stackable container only  
Blade agitator assembly (wet blade)  
Heavy-duty retainer nut  
791  
891  
Sound-reducing centering pad  
Drive socket  
791  
891  
Sound-reducing centering pad  
Drive socket  
PLS207  
760  
PLS112  
XDM034  
Variable speed control knob / timer control knob  
Accelerator Tool  
Rubber Feet  
PLS207  
760  
PLS112  
XDM034  
Variable speed control knob / timer control knob  
Accelerator Tool  
Rubber Feet  
Use and Care manual (not shown)  
Use and Care manual (not shown)  
NOTE: Other than the drive socket, blade assembly and retainer nut, this unit is not  
user serviceable.  
NOTE: Other than the drive socket, blade assembly and retainer nut, this unit is not  
user serviceable.  
#1159  
#1159  
Items Sold Separately:  
Items Sold Separately:  
#755  
#755  
#1191  
#756  
#1191  
#1195  
#15507  
#15506  
#15507  
#15504  
#1192  
#1192  
#15526  
#15502  
#15526  
#15502  
#15596 - Retainer Nut Wrench  
#15596 - Retainer Nut Wrench  
#758  
#758  
#1151  
#1152  
PLS145 - One-Piece Lid  
#15649  
PLS145 - One-Piece Lid  
#15649  
#836  
#791  
#891  
#836  
#791  
#891  
#15647  
#15640  
#15647  
#15652  
#15648  
#15643  
#15648  
#15643  
#760  
#760  
#PLS207  
#PLS112  
#PLS207  
#PLS112  
32 oz. / 0.9 Ltr. Container  
32 oz. / 0.9 Ltr. Container  
14  
15  
1. Problem:  
• Increased vibration  
Solution #1:  
Dimensions:  
Check blade assembly for loose, damaged  
or nicked components and replace.  
Solution #2:  
• Leaking from bottom of container  
• Increased container noise  
Tighten retainer nut with retainer nut wrench  
moving clockwise until it is snug. See page 10.  
2. Problem:  
• Machine will not run  
Solution #1:  
Double-check to make sure power cord is  
firmly in power outlet.  
Solution #2:  
Check to make sure switches are clean  
and moving freely.  
Solution #3:  
The thermal protector may have shut the  
machine off. Turn power off for up to 45  
minutes to reset. Note: Cooling may be  
quickened by placing the motor base in a  
cool spot. (Unplug first.) Try circulating the  
air with a fan or vacuum aimed at the  
bottom of the motor base.  
64 oz. / 2.0 Ltr.  
Overall Dimensions of 64 oz. / 2.0 Ltr. Polycarbonate Container with lid and base:  
20 in. / 51 cm High x 8 in. / 20.3 cm Deep x 9 in. / 22.9 cm Deep  
Overall Dimensions of 48 oz. / 1.4 Ltr. Polycarbonate Container with lid and base:  
17.5 in. / 44 cm High x 8 in. / 20.3 cm Wide x 9 in. / 22.9 cm Deep  
Ship weight of machine: 13 lbs. / 5.9 kg  
3. Problem:  
Solution:  
• Loud noise from blade area  
• Blades don’t spin  
Drive Socket may be broken. Check for a  
fine crack down the center or worn teeth –  
replace with a new drive socket (Item  
#891). Instructions are included with part.  
Power Requirements:  
Volts: 120 VAC  
Amps: 11.5 (2+ peak hp*)  
12.5 (3+ peak hp*)  
Hz: 50/60  
Volts: 220-240 VAC  
Watts: 750-850 (2+ peak hp*)  
Watts: 1100-1200 (3+ peak hp*)  
Hz: 50/60  
4. Problem:  
Solution:  
• BarBoss Pulse/Timer Blender will  
not run when START/STOP TIMER  
switch is activated  
Check ON/OFF power switch to make  
sure the switch is in the ON position.  
Note: START/STOP TIMER switch is lit  
when power is on.  
Volts: 100 VAC (Japan)  
Watts: 900 (2+ peak hp*)  
Watts: 975 (3+ peak hp*)  
Hz: 50/60  
Volts: 120 VAC EMC (Taiwan)  
Amps: 11.5 (2+ peak hp*)  
Hz: 60  
Cooling the motor:  
Machine may stop working if it is overloaded on low speed. Reset by turning power  
off for 30 seconds. Do not turn power off midway through a blending cycle. To interrupt  
cycle, press START/STOP TIMER switch one time. See page 4.  
*varies with voltage  
If you cannot fix your machine with these suggestions, technical help is available by  
calling 800-4DRINK4 (800-437-4654) or 440-235-0214. If outside the United States and  
Canada, contact your local Vita-Mix Distributor or telephone the Vita-Mix International  
Division at +1.440.782.2450 or email international@vitamix.com for a distributor in  
your country.  
16  
17  
PLEASE NOTE: The Service Contract outlined in the following paragraphs applies  
only to customers in the United States and Canada. Customers in all other countries  
should contact their local Vita-Mix® Distributor for service details.  
Limited Warranty  
Vita-Mix® Corporation warrants your Commercial Vita-Mix machine to be free from  
defects in materials and workmanship for a period of three years from the date of  
purchase when used in accordance with the accompanying instruction booklet.  
This Vita-Mix machine includes a 1-Year Service Contract effective from date of  
purchase. In the event your machine should need parts or repairs covered under this  
Service Contract, call Vita-Mix Customer Service immediately for instructions. Proof of  
date of purchase may be required. This does not cover abuse, misuse, tampering,  
improper installation or extreme conditions.  
Provisions of this limited warranty are void if your Vita-Mix machine has been  
subjected to obvious abuse, negligence, accident, alteration, or failure to follow  
operating instructions, or product exposure to abnormal or extreme conditions.  
Cosmetic changes such as discoloration of parts of the product in the hands of the  
user or the effects of the use of abrasive cleaners will not be warranted or considered  
defects. The cleaning or removal of food products along with any damage caused by  
allowing them to build up is not covered by this limited warranty. Warranty is void if  
the Vita-Mix machine is put into a sound reduction chamber that does not allow proper  
cooling.  
The Vita-Mix Service Contract includes the following:  
1. One extra drive socket – to facilitate simple repairs and prevent down time – is  
included and packaged with each machine.  
2. Additional drivers and accelerator tool, unless defective, are not covered. NOTE:  
to determine if you have a defective part, please order a replacement part through  
Vita-Mix Customer Service and, when the new part arrives, return the old part in the  
same packaging. Vita-Mix will inspect the returned part and, if defective, issue a  
refund for the price of the new part. A part will be considered defective if no abuse  
or neglect was involved with its break. Non-defective parts sent to Vita-Mix for  
inspection will not be returned if deemed unusable. Service Contract covers  
functionality of the machine but not abuse or lack of recommended maintenance.  
In the event your Vita-Mix machine needs service or repair covered by the terms of this  
warranty, please call the Vita-Mix Corporation for shipping instructions. The Vita-Mix  
machine must be sent in original or sufficient packaging.  
This limited warranty is in lieu of any other warranty expressed or implied. No  
representative or any other person is authorized to make any other warranty or to  
assume any liability not strictly in accordance with the foregoing. This limited warranty  
gives you specific legal rights which may vary from state to state. Proof of purchase  
may be required to prove date of purchase.  
3. In the Continental United States, sender pays freight one way to Vita-Mix  
Corporation. The Vita-Mix Corporation will pay UPS ground freight charges to  
return the machine to the sender. Sender pays costs for special shipping requests.  
Outside the Continental United States, other service contracts may apply.  
Outside the United States and Canada, other warranties may apply. Call or check  
with your Vita-Mix Distributor for details or telephone the Vita-Mix International Division  
at +1.440.782.2450 or email [email protected].  
In case of shipping damage, notify the shipper or carrier immediately. Outside the  
United States and Canada, contact your local Vita-Mix Distributor.  
Before returning this product for any reason, including repair, please first contact  
our Customer Service Department. In the US and Canada, call 800-4DRINK4  
(800-437-4654) or 440-235-0214 to receive a “RETURN AUTHORIZATION”  
NUMBER. Any return without a “Return Authorization” Number will not be  
processed and will be returned to sender. Outside the United States, contact  
your local Vita-Mix Distributor.  
NOTE: Within the United States, Limited Warranty and Service Contract are honored  
directly through the Vita-Mix Corporation, Cleveland, Ohio USA. Non-warranty repairs  
can be performed by any CFESA service center. For machines sold in the United  
States, call Vita-Mix: 800-4DRINK4 (800-437-4654) or 440-235-0214. If you live outside  
the United States or Canada, contact your local Vita-Mix Distributor, or telephone the  
Vita-Mix International Division at +1.440.782.2450 or email [email protected]  
for a distributor in your country.  
18  
19  
®
Additional Vita-Mix Accessories Available!  
To rinse containers  
quickly between  
servings, the  
To scrub tough  
ingredients, use the  
new Vita-Mix Container  
Brush. Soft, flexible  
fibers scrub in seconds  
but won’t scratch!  
Item #15639  
Vita-Mix  
Rinse-o-matic®  
is ideal. Rinses  
clean in seconds!  
Item #1410  
For more information on these accessories, call 800-4DRINK4 (800-437-4654)  
or 440-235-0214. If you live outside the United States or Canada, contact your local  
Vita-Mix Distributor or telephone the Vita-Mix International Division at +1.440.782.2450  
or email [email protected] for a distributor in your country.  
To see the complete line of Vita-Mix products,  
VITA-MIX® CORPORATION  
Foodservice Division  
8615 Usher Road, Cleveland, Ohio 44138-2103 USA  
©2006 Vita-Mix Corporation. No part of this publication may be reproduced or transmitted in any form or  
by any means, electronic or mechanical, including photocopy, recording or any information storage and retrieval system  
without the written permission of the Vita-Mix Corporation.  
Printed in U.S.A.  
XDM034 03/06  

Zanussi MINI HI FI SYSTEM FWD831 User Manual
Tokina MOTORIZED ZOOM LENS TM10Z0818GAI User Manual
Sony XR C5500 User Manual
Sony HDW 750CE User Manual
Sony DCR TRV40E User Manual
Sony CFD S100 User Manual
Sony CDX gt929u User Manual
Sony Blu ray Disc Player BDP S590 User Manual
Sanyo VCC 6592P User Manual
Rosen Entertainment Systems DA 7169 User Manual