Turbo Air TCB 2SD User Manual

Turbo air Speeds Up the Pace of Innovation  
Beer Dispenser & Back-Bar Cooler  
Installation and Operation Manual  
Please read this manual completely before attempting to install or operate this equipment!  
TCB-2SD,TCB-3SD, TCB-4SD(Stainless Steel)  
TCB-2SB,TCB-3SB, TCB-4SB(Black Paint)  
TBD-1SD, TBD-2SD, TBD-3SD, TBD-4SD(Stainless Steel)  
TBD-1SB, TBD-2SB, TBD-3SB, TBD-4SB(Black Paint)  
TBB-1SB, TBB-2SB, TBB-3SB, TBB-4SB(Solid Door)  
TBB-2SG, TBB-3SG, TBB-4SG(Glass Door)  
This equipment is intended for the storage and display of non-potentially hazardous, bottled or canned  
products only  
INSTALLATION OF THE CASTERS  
According to model, refer to the assembly position of casters.  
TCB-2SD, TBD-2SD, TBB-2SB, TBB-2SG  
TCB-3SD, TBD-3SD, TBB-3SB, TBB-3SG  
TCB-4SD, TBD-4SD, TBB-4SB, TBB-4SG  
This picture is a plan view of bottom cabinets.  
CB is an abbreviation of the caster with a brake.  
Other casters don't have a brake.  
DRAFT ARMS TOWERS Installation Schematic Diagram  
Screw(M4xL12) x 4EA  
Screw(M4xL12) x 4EA  
Draft Tower Assembly  
Rubber Gasket  
Draft Tower Assembly  
Rubber Gasket  
TCB-2SD, TCB-3SD, TCB-4SD  
TBD-2SD, TBD-3SD, TBD-4SD  
TBD-2SB, TBD-3SB, TBD-4SB  
* Assemble DRAFT TOWER as above drawing.  
3
Turbo air  
2
BEER LINE & CO LINE Installation Schematic Diagram  
Distributor Fixture  
CO2 Line  
CO2  
Beer Line#1  
Beer Line#2  
Beer #1  
Beer #2  
TCB-2SD, TCB-3SD, TCB-4SD  
TBD-2SD, TBD-3SD, TBD-4SD  
TBD-2SB, TBD-3SB, TBD-4SB  
* Assemble BEER LINE & CO2 LINE as above drawing.  
4
Turbo air  
CAUTION "IMPORTANT"  
DIRECT DRAW  
On direct-draw dispensers the drain is  
located at the front of the cabinet.  
To plumb in the drain, connect 5/8”  
P.V.C. pipe to the 5/8” barbed fitting  
supplies with the unit.  
* Don't pull out or Turn drain line.  
5
Turbo air  
CAUTION "IMPORTANT"  
TBB-2SG, TBB-3SG,  
TBB-4SG  
A. Excessively opening the door will cause the breakdown.  
B. Handle with care as shutting the door.  
1. POWER CORD  
- Be sure the power cord is connected to the proper voltage, and amps  
should be run before connecting power cord to outlet.  
- A protected circuit of the correct voltage and amperage must be run for  
connection of the line cord.  
- Unplug the unit, whenever performing maintenance functions or cleaning  
the refrigerated cabinet.  
- Compressor warranty is void if burnt out due to low voltage.  
2. RE-STARTING  
- If unpluged, wait 5 minutes before re-starting.  
6
Turbo air  
INSTALLATION  
1. GOOD AIR CIRCULATION  
- Do not place any object that will restrict air flow in front or back grills.  
- Turbo air highly recommends that there is ample space in rear of unit. 3 inches or  
more is best.  
2. PLACE ON STRONG GROUND  
- Be sure the location chosen has a floor strong enough to support the total weight of  
the cabinet and contents.  
3. DO NOT PLACE NEAR HEAT  
- Be sure to avoid hot corners and locations near stoves.  
- High ambient temperature will make cooling efficiency lower.  
4. INDOOR USAGE ONLY  
- Be sure to install this unit indoor, so it will not get wet from the rain.  
5. STABILIZING  
- Make sure the unit is installed in a stable condition.  
6. LEVELING  
- Be sure that the unit is level from front to back and side to side.  
7. Do not plug in with other units on same breaker.  
8. Do not run on extension cord.  
7
Turbo air  
CLEANING  
Before cleaning, unplug the unit.  
1. CLEANING THE INTERIOR AND EXTERIOR  
- The interior and exterior of the unit can be cleaned using warm water with soap.  
- Do not use an abrasive cleaner because it will scratch the surface.  
2. CLEANING THE CONDENSER FINS  
- To maintain proper refrigeration performance, the Condenser coil must be free of  
dust, dirt, and grease.  
This will require periodic cleaning. Condenser fins should be cleaned at least every  
three months (90 days) or as needed.  
- To clean condenser, unplug the unit. Condenser can be cleaned with vacuum, brush,  
or CO2 (high pressure air).  
3. CLEAN THE GASKET  
- The door gasket should be cleaned frequently to maintain proper sealing.  
4. CLEAN THE DRAIN PAN  
- Empty the Drain Pan which is located under the unit, periodically.  
- When reinstalling Drain Pan, make sure Drain Hose is placed back in pan.  
5. CHECK AFTER CLEANING  
- Plug unit back in.  
- Check that the unit is operating properly.  
8
Turbo air  
BASIC OPERATION  
REFRIGERATORS  
1. The controller(thermostat) is located at the back right inside of the unit.  
2. The factory setting maintains about 38˚F(3˚C) inside.  
3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder  
temperature.  
Temperature Controller  
(Thermostat)  
4. The thermostat controls compressor’s cycling by sensing inside temperature.  
5. When unit will not be used for a long time, unplug the unit.  
9
Turbo air  
BEFORE REQUESTING SERVICE  
SYMPTOMS  
CAUSES  
SOLUTIONS  
Cooler is freezing  
products  
• Thermostat set too cold.  
• Turn the temperature dial to a  
warmer setting.  
The unit does not  
refrigerate at all.  
• There is a power connection  
failure problem.  
• Check the power cord to make  
sure the unit is pluged in it  
correctly.  
The unit does not  
refrigerate well.  
• The unit is in sunlight or near a • Move out of sunlight or away  
heating device.  
from heater.  
• Product was put in warm.  
• The unit door is opened too  
• Check the condition of stored  
food.  
frequently or left open too long. • Check the position of the temp  
• The temp. dial is not on the  
correct position.  
control dial.  
• The condenser is clogged.  
There is a loud noise.  
• The floor is too weak or the  
leveling feet are set incorrectly.  
• The backside of the unit is too  
close to the wall.  
• Check the installation.  
There are dew-drops  
on the unit exterior.  
• High-moisture air can produce • Wipe with a dry cloth.  
dewdrops during rainy seasons.  
There are dew-drops  
on the unit interior.  
• The door is opened too  
frequently or left open too long.  
• Keep the door closed to  
remove dewdrops.  
The following points are not malfunctions:  
• A water-flowing sound can be heard when the compressor stops.  
This is the sound of REFRIGERANT flowing.  
• The compressor does not run during the defrost cycle.  
10  
Turbo air  
Warranty  
Warranty Claims  
All claims for labor or parts must be made directly through Turbo Air. If unit was manufactured more than one year,  
proof of purchase must be faxed in or sent with claim. All claims should include: model number of the unit, the serial  
number of the cabinet, and all pertinent information supporting the existence of the alleged defect.  
If compressor is replaced under warranty, Turbo Air will either request the compressor or compressor tag be returned.  
Compressor or tag must be returned with all information related to the unit. Any action or breach of these warranty  
provisions must be commenced within one year after said cause of action has occurred.  
One Year Parts & Labor Warranty  
Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof,  
to be free from defects in material or workmanship, under normal and proper use and maintenance service as  
specified by Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied  
with each Turbo Air unit. Turbo Air’s obligation under this warranty is limited to a period of one (1) year from the date  
of original installation or 15 months after shipment date from Turbo Air, whichever occurs first.  
Any parts, covered under this warranty, that are determined by Turbo Air to have been defective within one (1) year  
of original installation or fifteen (15) months after shipment date from manufacturer, whichever occurs first, is limited to  
the repair or replacement, including labor charges, of defective parts or assemblies. The labor warranty shall include  
standard straight time labor charges only and reasonable travel time, as determined by Turbo Air.  
Additional Four Year Compressor Warranty  
In addition to the one (1) year warranty stated above, Turbo Air warrants its hermetically sealed compressor to be free  
from defects in both material and workmanship under normal and proper use and maintenance service for a period of  
four (4) additional years from the date of original installation, but not to exceed five (5) years and three (3) months  
after shipment from the manufacturer.  
Compressor determined by Turbo Air to have been defective within this extended period will, at Turbo Air’s option, be  
either repaired or replaced with a compressor or compressor parts of similar design and capacity.  
The four (4) year extended compressor warranty applies only to hermetically sealed parts of the compressor and  
does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature  
control, refrigerant, metering device, driers, motor starting equipment, fan assembly or and other electrical  
component, etcetera.  
404A / 134A Compressor Warranty  
The four-year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:  
1.  
2.  
3.  
This system contains R404A or R134A refrigerant and polyolester lubricant. The polyol ester lubricant has  
rapid moisture absorbing qualities.  
Drier replacement is very important and must be changed when a system is opened for servicing. A 620  
copper drier or better is highly recommended.  
Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower  
must be obtained.  
4.  
5.  
When compressor is grounded, suction filter drier and 620 drier or better must be replaced.  
Compressor must be obtained through Turbo Air Inc., unless otherwise specified in writing, through Turbo  
Air’s warranty department.  
11  
Turbo air  
What Is Not Covered By This Warranty  
Turbo Air’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the  
additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other  
than those expressly covered by this warranty.  
NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT  
LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,  
LOSSES, OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT  
BECAUSE of REFRIGERATION FAILURE.  
WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original  
purchaser / user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES  
HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY  
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
IMPROPER USAGE. TURBO AIR ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR  
COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER USAGE OR INSTALLATION  
OR FAILURE TO CLEAN AND / OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET  
PROVIDED WITH THE UNIT.  
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION,  
FIRE, FLOOD, ACTS OF GOD. Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air  
determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident,  
damage during transit or installation, fire, flood, or act of God.  
IMPROPER ELECTRICAL CONNECTIONS. TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR  
REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER  
FAILURE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT.  
NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE: THERE  
ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE ONE (1) YEAR  
PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY AS  
DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,  
INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.  
OUTSIDE U.S. AND CANADA: This warranty does not apply to, and Turbo Air is not responsible for, any warranty  
claims made on products sold or used outside the United State and Canada.  
CHANGES MADE TO WARRANTY COMMENCED ON 5/1/2002  
12  
Turbo air  
1250 Victoria street  
CARSON, CA 90746  
TEL: 310-900-1000  
FAX: 310-900-1077  
Toll Free: 1-800-627-0032  
(U.S.A. In Canada)  
13  
Turbo air  

Weil McLain EGH Series 4 User Manual
Vivitar DVR 910HD User Manual
Tamron SP 272E User Manual
Speco Technologies VM 901B User Manual
Sony XR 3304 User Manual
Sony UX20E User Manual
Sony PDW F355L User Manual
Sony DCR PC9 User Manual
Sony Camcorder DVW 970P User Manual
Sanyo Car Satellite TV System DP39843 User Manual