Raypak 133 User Manual

Raytherm® - Type H  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Hydronic Heating Boilers  
Residential Œ Commercial  
Date:  
Model 133  
Indoor/Outdoor:  
EFFICIENT  
82% thermal efficiency – highest of any atmospheric  
boiler available today  
THERMAL SHOCK PROOF  
Twenty-year warranty against thermal shock damage  
up to 150°F differential  
Maximum operating temperature: 230°F  
LIGHTWEIGHT  
A floor load of 70 lbs./sq. ft. or less  
HIGH RECOVERY  
Cuts fuel costs substantially because the standby and  
radiation losses normal to other boilers are eliminated  
LOW WATER OPERATING TEMPERATURE  
Operates with water temperature as low as 105°F  
without condensing  
INDOOR MODEL  
Construction  
Heat Exchanger  
Gas Train  
ƒ
ASME Inspected and Stamped  
160 PSIG  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Main Gas Shut-off Cock  
ƒ
ƒ
ƒ
ƒ
Front Controls  
Main Gas Pressure Regulator  
Redundant Safety Shut-off Valve  
Control Valve  
Mechanical Modulation (H1)  
Fuel  
Natural Gas  
Propane Gas  
Design Certified ANSI Z21.13/  
CSA 4.9  
Stainless Steel Burners  
Polytuf Powder Coat Finish  
Vent Selection  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
National Board Approved  
Glass-lined Cast Iron Headers  
Copper Finned Tubing  
ASME Steel Tube Sheet  
Silicone O-Rings  
45 PSIG ASME Pressure Relief  
Valve  
Temperature and Pressure Gauge,  
Shipped Loose  
Draft Diverter (Indoor) –  
Option D-10  
Stackless Top (Outdoor) –  
Option D-11  
High-Wind Top (Outdoor) –  
Option D-13  
ƒ
ƒ
ƒ
ƒ
Base – Optional  
ƒ
ƒ
Rear Water Connection  
Pump – Optional  
Combustible Floor Shield –  
Option J-1  
Vent Damper – Indoor Residential  
models only  
Bronze, 1/8 HP, 120 Volt, 1∅, 60 Hz  
Cast Iron, 1/8 HP, 120 Volt, 1∅,  
60 Hz  
NOTE: Unit cannot be installed  
outdoors in residential applications.  
Controls  
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1 Ph Power Supply  
120/24V Transformer  
100% Pilot Shut-off/Lockout  
Electronic, Intermittent Ignition (IID)  
Pilot  
ƒ
ƒ
ƒ
ƒ
High Limit Control - Automatic  
On/Off Switch  
Operating Limit Control  
Economaster II Pump Time Delay  
Catalog No.: 2000.20P  
Effective: 12-1-07  
Replaces: 4-1-05  

Planar Systems Car Video System PT1945RW User Manual
Planar Systems Car Video System LX1501PTI User Manual
Planar Systems Car Video System LA1950RTR User Manual
Panasonic DVCPRO AJ SDC615P User Manual
Panasonic AJ HPX3700 User Manual
Orion Car Audio HCCA52 User Manual
Motorola DJ Headphone S805 User Manual
Lochinvar Copper Fin CB CW 495 745 User Manual
KitchenAid KFP715WH2 User Manual
JVC KS FX202 User Manual