Pelco Camera Lens C2410M H User Manual

ADDENDUM  
Addendum No. C3409M  
Date December 22, 2005  
Manuals Affected C2462M-B, C2403M-C, C2410M-H,  
C2491M-B, C2496M  
Manual Update Switch Settings for Varifocal Lens  
Manual Update The high resolution camera with vari-  
focal lens and auto iris is configured at  
the factory for automatic exposure.  
SWITCH SETTINGS FOR VARIFOCAL LENS  
The high resolution camera with varifocal lens and auto iris is configured at the factory for  
automatic exposure.  
1
2
3
4
5
6
7
8
AWB Automatic white balance  
GAM Gamma function  
FACTORY SETTINGS  
1
2
3
4
5
6
7
8
AGC  
ESC  
BLC  
Automatic gain control  
Electronic shutter control  
Backlight compensation  
Flickerless  
ON  
OFF  
OFF  
= SWITCH POSITION  
FL  
AE  
Automatic exposure  
Not used  
Figure 1. Switch Settings for Varifocal Lens  
Pelco Worldwide Headquarters  
3500 Pelco Way • Clovis, California 93612 USA  
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150  
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120  
CONTENTS  
Section  
Page  
IMPORTANT SAFETY INSTRUCTIONS ........................................................................................................ 3  
REGULATORY NOTICES ............................................................................................................................... 3  
DESCRIPTION .............................................................................................................................................. 4  
INSTALLATION ............................................................................................................................................. 4  
INSTALL BACK BOX ........................................................................................................................... 4  
MOUNTING DIRECTLY TO WALL OR CEILING ........................................................................ 4  
MOUNTING TO 4S DEEP ELECTRICAL BOX ............................................................................ 5  
MOUNTING TO CEILING TILE .................................................................................................. 5  
INSTALL CAMERA ............................................................................................................................. 5  
INSTALL DOME AND TRIM RING ..................................................................................................... 7  
ADJUSTMENTS (COLOR CAMERA ONLY) .................................................................................................. 7  
VERTICAL PHASE (24 VAC OPERATION ONLY) ................................................................................. 7  
AUTO IRIS LEVEL ADJUSTMENT ...................................................................................................... 8  
FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS .................................... 8  
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS ......................................... 9  
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS .................................. 9  
SWITCH SETTINGS FOR VARIFOCAL LENS ..................................................................................... 10  
SPECIFICATIONS .......................................................................................................................................... 11  
[ 2 ] Pelco Manual C2410M-H (10/05)  
IMPORTANT SAFETY INSTRUCTIONS  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.  
6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (in-  
cluding amplifiers) that produce heat.  
7. Only use attachments/accessories specified by the manufacturer.  
8. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the  
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid  
injury from tip-over.  
9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been  
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or ob-  
jects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not  
operate normally, or has been dropped.  
10. Installation should be done only by qualified personnel and conform to all local codes.  
11. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is de-  
signed for indoor use only and it must not be installed where exposed to rain and moisture.  
12. Use only installation methods and materials capable of supporting four times the maximum specified  
load.  
13. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the  
risk of electric shock do not perform any servicing other that contained in the operating instructions  
unless you are qualified to do so.  
14. Only use replacement parts recommended by Pelco.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage Constituting a  
risk of electric shock is present within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
This symbol indicates that there are important operating and  
maintenance instructions in the literature accompanying this unit.  
DO NOT OPEN.  
REGULATORY NOTICES  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and (2) this device must accept any interference re-  
ceived, including interference that may cause undesired operation.  
FCC, Class A (black-white, EIA and CCIR cameras - except auto iris models)  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant  
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference when the equipment is operated in a commercial environment. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the in-  
struction manual, may cause harmful interference to radio communications. Operation of this equipment  
in a residential area is likely to cause harmful interference in which case the user will be required to cor-  
rect the interference at his own expense.  
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment  
can void your authority to operate this equipment under Federal Communications Commissions rules.  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.  
Pelco Manual C2410M-H (10/05)  
[ 3 ]  
FCC, Class B (color, NTSC and PAL cameras - except auto iris models)  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant  
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency  
energy and, if not installed and used in accordance with the instructions, may cause harmful interference  
to radio communications. However there is no guarantee that the interference will not occur in a particu-  
lar installation. If this equipment does cause harmful interference to radio or television reception, which  
can be determined by turning the equipment off and on, the user is encouraged to try to correct the inter-  
ference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV technician for help.  
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve  
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,  
Washington D.C. 20402.  
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment  
can void your authority to operate this equipment under Federal Communications Commissions rules.  
This Class B digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  
DESCRIPTION  
The 150 Series Camclosure® Integrated Camera System is an in-ceiling dome incorporating a camera  
and lens package into a small, discreet, high-security enclosure designed for areas subject to heavy  
vandalism.  
INSTALLATION  
1 Install Back Box  
Mounting Directly to Wall or Ceiling  
1. Cut a hole 3.5 inches (9 cm) in  
diameter in the ceiling or wall  
using the adapter plate as a  
template.  
2. Connect the video cable.  
3. Connect the power wires.  
For 12 VDC, connect the  
24 VAC/12 VDC (red) and GND (black)  
wires to input power.  
For 24 VAC, connect the 24 VAC/12 VDC (red)  
and 24 VAC (blue) wires to input power.  
4. Attach the back box to the wall or ceiling.  
[ 4 ] Pelco Manual C2410M-H (10/05)  
Mounting to 4S Deep Electrical Box  
1. Attach adapter plate to the 4S box  
with the two 8-32 x .750-inch  
screws.  
4S DEEP  
ELECTRICAL  
BOX  
2. Connect the video cable.  
WALL OR  
CEILING  
8.32 X .750 SCREW  
(SUPPLIED)  
3. Connect the power wires.  
ADAPTER PLATE  
For 12 VDC, connect the  
BACK BOX  
24 VAC/12 VDC (red) and GND  
(black) wires to input power.  
For 24 VAC, connect the  
01063  
8.32 X .375 SCREW  
(SUPPLIED)  
24 VAC/12 VDC (red) and  
24 VAC (blue) wires to input power.  
4. Attach the back box to the adapter plate  
with the four 8-32 x .375-inch screws.  
ADAPTER PLATE  
Mounting to Ceiling Tile  
CEILING TILE  
BACK BOX  
1. Remove the ceiling tile.  
2. Using the adapter plate as a template, cut  
a hole 3.5 inches (9 cm) in diameter in the  
ceiling tile for the back box. Punch four  
screw holes in the ceiling tile.  
8-32 X 1.25  
MOUNTING  
HARDWARE  
(SUPPLIED)  
01062  
3. Attach the back box to the ceiling tile and adapter plate with the four 8-32 x 1.25-inch screws (see  
diagram).  
4. Replace the ceiling tile.  
5. Remove an adjacent ceiling tile and connect the video cable.  
6. Connect the power wires.  
For 12 VDC, connect the 24 VAC/12 VDC (red) and GND (black) wires to input power.  
For 24 VAC, connect the 24 VAC/12 VDC (red) and 24 VAC (blue) wires to input power.  
C A U T I O N  
Heater elements could be hot! When camera power is on, use caution when  
adjusting the camera. This applies to all models.  
2 Install Camera  
HEATER  
BOARD  
1. Some indoor installations do not require a  
heater. If the installation does not require a  
heater, remove the heater board from the  
camera assembly. To remove the heater  
apply pressure and press on the corner of  
the board.  
1092  
Pelco Manual C2410M-H (10/05)  
[ 5 ]  
VIDEO  
2. 12 VDC Operation Only - The camera  
is set for 24 VAC operation at the  
factory. For 12 VDC operation re-  
move the jumper from  
CONNECTOR  
HEATER  
CONNECTOR  
the 24 VAC position  
and install it on the  
24 VAC JUMPER  
12 VDC JUMPER  
12 VDC position.  
01065  
3. If the heater is installed, plug the  
heater connector from the camera into the  
mating connector inside the base. Plug the  
video connector from the camera into the  
mating connector inside the base.  
Turn on power to the camera and monitor.  
VIDEO  
CONNECTOR  
HEATER  
CONNECTOR  
4. If you have a varifocal lens, hold the assembly in  
your hand and point the lens toward what you want  
to view. Loosen the focal length and focus locking  
screws. Adjust according to scene detail. Retighten  
the screws.  
01068  
5. Always make sure the tab on the camera bracket is point-  
ing out of the enclosure (away from the ceiling or wall).  
Gently squeeze the bracket, place it against the shoulder  
inside the back box, and gently release.  
Proper camera orientation:  
CAMERA BRACKET  
TAB ALWAYS POINTS  
OUT OF THE  
ENCLOSURE  
TOP OF  
CAMERA  
01086  
CAMERA BRACKET  
TAB ALWAYS POINTS  
OUT OF THE  
ENCLOSURE  
01071  
Wall Mounting - The camera bracket  
tab points out of the enclosure and the  
top of the camera points up towards  
the tab.  
Ceiling Mounting - The camera  
bracket tab points out of the enclo-  
sure and the top of the camera is  
pointed in the opposite direction.  
[ 6 ] Pelco Manual C2410M-H (10/05)  
3 Install Dome and Trim Ring  
Place the trim ring and dome over the back box. If the  
dome has a liner, position the viewing window over the  
lens of the camera. Tighten the tamper-resistant screws  
with the supplied 1/8-inch hollow screwdriver bit. Note  
that the screws are installed at an angle.  
01074  
ADJUSTMENTS (COLOR CAMERA ONLY)  
If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes,  
however, adjustments may be necessary.  
1. Remove the dome and trim ring using the supplied 1/8-inch hollow screwdriver bit.  
2. Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below).  
3. Replace the dome and trim ring.  
Vertical Phase (24 VAC Operation Only)  
Adjustment is required if there is vertical roll when switching between two cameras.  
1. Reverse the 24 VAC connections on one camera. If both cameras are connected to the same trans-  
former, this should solve the problem.  
2. If reversing the connections does not solve the problem, or if cameras are connected to different trans-  
formers, turn the adjustment screw on one camera (while switching as rapidly as possible between the  
two camera views) until the switching is clean and there is no vertical roll. If more than two cameras are  
out of synchronization with each other, choose one camera and synchronize all others to it.  
FIXED LENS  
VARIFOCAL LENS  
VERTICAL PHASE  
ADUSTMENT  
VERTICAL  
PHASE  
ADJUSTMENT  
Pelco Manual C2410M-H (10/05)  
[ 7 ]  
Auto Iris Level Adjustment  
If you have a varifocal lens or fixed focal length lens with an auto iris, you can adjust the level setting to  
increase or decrease brightness.  
VARIFOCAL LENS  
VERTICAL PHASE  
ADUSTMENT  
Focus Adjustment for Fixed Focal Length Lens with Auto Iris  
C A U T I O N  
Heater elements could be hot! When camera power is on, use caution when  
adjusting the camera.  
To adjust the focus, it may be necessary to remove the heater board in order to loosen the locking screw  
on the bottom of the lens.  
To remove the heater board:  
HEATER  
BOARD  
1. Disconnect the four-pin heater wiring.  
2. Wait for the heater elements to cool if they are hot.  
3. Apply pressure and press on the corner of the board.  
To adjust the focus:  
FOCUS  
1. Loosen the locking screw on the bottom of the lens.  
2. Move the screw in the slot to bring the picture into focus.  
3. Retighten the locking screw.  
ADJUSTMENT  
SCREW  
4. Replace the heater board if it was removed.  
5. Reconnect the four-pin heater wiring.  
ADJUSTMENT  
SLOT  
BOTTOM VIEW OF CAMERA WITH  
HEATER BOARD REMOVED  
[ 8 ] Pelco Manual C2410M-H (10/05)  
Switch Settings for Fixed Focal Length Lens with Auto Iris  
Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation  
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions  
where there are no bright spots that darken other picture details. Manual backlight compensation is used  
in fixed lighting conditions to optimize the picture detail when there are bright spots.  
ALC/ELC switch:  
Always ALC  
Always DC  
FACTORY SETTINGS  
Y/DC switch:  
Auto backlight compensation:  
BLC switch OFF  
ABL switch ON  
ON  
OFF  
Manual backlight compensation: BLC switch ON  
ABL switch OFF  
= SWITCH POSITION  
Switch Settings for Fixed Focal Length Lens Without Auto Iris  
Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation  
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions  
where there are no bright spots that darken other picture details. Manual backlight compensation is used  
in fixed lighting conditions to optimize the picture detail when there are bright spots.  
ALC/ELC switch:  
Always ELC  
Not used  
FACTORY SETTINGS  
Y/DC switch:  
Auto backlight compensation:  
BLC switch OFF  
ABL switch ON  
ON  
OFF  
Manual backlight compensation: BLC switch ON  
ABL switch OFF  
= SWITCH POSITION  
01061  
Pelco Manual C2410M-H (10/05)  
[ 9 ]  
Switch Settings for Varifocal Lens  
The high resolution camera with  
1
2
3
4
5
6
7
8
AWB Automatic white balance  
GAM Gamma function  
AGC Automatic gain control  
ESC Electronic shutter control  
BLC Backlight compensation  
FACTORY SETTINGS  
varifocal lens and auto iris is  
configured at the factory for  
optimal performance in lighting  
conditions where auto iris is  
required. It is also configured with  
the shutter speed set at 1/60  
(NTSC) or 1/50 (PAL) and manual  
gain set at 6 dB.  
1
2
3
4
5
6
7
8
FL  
Flickerless  
OFF  
AE  
Automatic exposure  
= SWITCH POSITION  
Not used  
01060  
For manually setting and locking the white  
balance  
Place a white background in front of camera and  
turn off switch 1.  
For gamma correction  
WARNING Do not change the shutter  
speed unless you understand how  
changing the settings will affect the  
scene detail.  
Switch to accurately reproduce scene brightness;  
when turned on, y = 0.6, and when turned off,  
y = 1.0.  
For automatic exposure  
Switch Number and Position  
Shutter  
Speed  
Turn on switch 7, and then turn on/off switch 3  
for AGC, switch 4 for electronic shutter control,  
switch 5 for backlight compensation, and switch  
6 for flickerless motion.  
7
6
5
4
1/60 (NTSC)  
1/50 (PAL)  
1/100  
1/250  
1/500  
1/1000  
1/2000  
1/4000  
1/10000  
On  
On  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
On  
Off  
Off  
Off  
Off  
Off  
For manual exposure and to enable auto iris  
Turn off switch 7; set switch 3 on to increase the  
gain by 6 dB or off to increase the gain by 18 dB;  
set switches 4, 5, and 6 for the desired shutter  
speed.  
[ 10 ] Pelco Manual C2410M-H (10/05)  
SPECIFICATIONS  
General  
Operating Temperature:  
-50° to 122°F (-46° to 50°C)  
De-ices to 25°F (-4°C)  
Pan/Tilt  
Adjustment:  
Construction:  
Finish:  
Manual; 360° pan; 180° tilt  
Aluminum with steel camera mounting bracket and polycarbonate dome  
White polyester powder coat trim ring with charcoal gray back box  
Dimensions  
Above Ceiling:  
1.75 (H) x 3.50 (W) inches  
(4.45 x 8.89 cm)  
Below Ceiling:  
2.42 (H) x 5.48 (W) inches  
(6.15 x 13.90 cm)  
Bubble:  
3.75-inch diameter  
Environment:  
Low temperature, indoor/outdoor, suitable for use in environmental air  
handling spaces  
1.70 lb (0.77 kg)  
Weight:  
Electrical  
Input Voltage:  
Power Consumption:  
Video Connector:  
12 VDC or 24 VAC, ±10%  
13 watts or less  
BNC  
(Design and product specifications subject to change without notice.)  
This equipment contains electrical or electronic components that must be recycled properly to comply  
with directive 2002/96/ec of the european union regarding the disposal of waste electrical and electronic  
equipment (weee). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
C2410M  
C2410M  
C2410M-A  
C2410M-B  
C2410M-C  
C2410M-D  
C2410M-E  
C2410M-F  
Date  
11/99  
1/00  
1/00  
7/00  
1/01  
7/01  
7/02  
5/03  
Comments  
Original version.  
Revised installation instructions. Added FCC notices.  
Added varifocal lens. Changed format.  
Added information on dome liner.  
Added heater element caution.  
Camera module redesigned, reference ECO 1-7054/7055/7056.  
Added instructions for fixed lens with auto iris.  
Revised Installation instructions – bracket and camera assembled at factory. Added iris  
level adjustment for fixed lens with auto iris.  
Added to certifications that all models are suitable for use in environmental air handling  
spaces.  
C2410M-G  
C2410M-H  
1/04  
10/05  
Revised drawings showing vertical phase and iris level adjustments. Revised switch-setting  
descriptions for varifocal lens. Added WEEE statement.  
Pelco Manual C2410M-H (10/05)  
[ 11 ]  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the  
date of shipment.  
Exceptions to this warranty are as noted below:  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2,  
CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Two years (except lamp and color wheel) on Digital Light Processing (DLP) displays. The lamp and color wheel will be covered for a pe-  
riod of 90 days. The air filter is not covered under warranty.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and EnduraSeries distributed network-  
based video products.months on DX Series digital video recorders, NVR300 Series network video recorders, EnduraSeries distributed  
network-based video products, and TW3000 Series twisted pair transmission products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan  
modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be  
sent freight  
will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent  
freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered  
under this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Prod-  
ucts. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liabil-  
ity, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any  
special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the  
negligence of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation  
from state to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number  
(RA), and provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a  
written explanation with the product when returned.  
Method of return shipment shall be the same or equal to the method by which the item was received by pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an  
authorization number (CA number if returned for credit, and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the  
appropriate address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one  
of the following  
If the goods are to be sent by a  
COURIER SERVICE, send the goods to:  
Pelco  
If the goods are to be sent by a FREIGHT  
FORWARDER, send the goods to:  
Pelco c/o Expeditors  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
©Copyright 2005, Pelco.  
All rights reserved.  
DLP is a registered trademark of Texas Instruments, Inc.  

RCA CC6271 User Manual
Pelco Camera Accessories PT570 User Manual
Panasonic DV PROLINE AG DVX100BP User Manual
Numark Industries Car Video System VM03 User Manual
Manhattan Computer Products Car Satellite Radio System ST100 User Manual
Lochinvar 5 User Manual
Konica Minolta Dynax 5D User Manual
Kenwood X SE9 User Manual
Kenwood KDC W6534U User Manual
JVC LVT1982 002A User Manual