Panamax MAX 4400 User Manual

INSTRUCTIONS MAX 4400  
®
Thank you for choosing Panamax.  
The MAX® 4400 is designed to  
provide AC power distribution and  
maximum protection for audio/  
video equipment.  
1. Plug the MAX® 4400 directly  
into a properly grounded 3-wire  
AC outlet*.  
TROUBLESHOOTING  
If you continue to have trouble  
with your MAX® 4400 or this sec-  
tion has not fixed the problem,  
please call PANAMAX Customer  
Relations Department at 800-472-  
5555.  
There is no AC power to my  
equipment, or my equipment  
doesn’t turn on .  
2. Turn the MAX® 4400 on.  
Make sure that the MAX® 4400 is  
plugged into a working AC outlet.  
Check all AC connections.  
3. Plug in one of the pieces of  
equipment you want to protect and  
turn the equipment on.  
Inductorless Noise Filtration  
Capacitive noise filtration allows  
amplifiers and powered sub-  
CONTACTING PANAMAX  
Make sure the MAX® 4400 and  
connected equipment is turned on.  
If you are using the 12VDC trigger,  
make sure that the source is actu-  
ally supplying the voltage needed  
For product and warranty informa-  
tion, dealer information, and other  
general information contact  
Customer Relations at:  
woofers to perform to their full  
potential. When the movie thun-  
ders with a terrific explosion or  
when the music reaches a climac-  
tic crescendo, an amplifier has to  
rapidly draw large amounts of cur-  
rent to replenish its power supply  
capacitors. Traditional line condi-  
tioners impede this current draw,  
in effect, starving an amplifier and  
resulting in a flat, dead sound.  
The MAX® 4400 provides clean,  
filtered power to amplifiers but has  
no current-limiting components to  
impede performance.  
If the equipment is working cor-  
rectly, continue to plug in and turn  
on your equipment.  
In the extremely unlikely event that to activate the MAX® 4400.  
everything does not work perfectly,  
Email:  
Web:  
Fax:  
707-283-5901  
stop and read the troubleshooting  
section. If you continue to have  
problems, call PANAMAX  
Customer Relations Department at  
800-472-5555, USA and Canada.  
Check to see if the circuit breaker  
on the MAX® 4400 needs to be  
reset (press in).  
Phone: 800-472-5555  
or 707-283-5900,  
The MAX® 4400 circuit breaker  
disconnects AC power from the  
connected equipment.  
You have exceeded the ampere rat-  
ing for your surge protector.  
7:30 a.m.- 5 p.m.PST  
*Many old buildings are inade-  
quately wired. It is very common  
for a building to be improperly  
grounded. Building wiring and  
grounding must conform to appli-  
cable NEC (USA) or CEC (Canada)  
codes for the PANAMAX connect-  
ed equipment policy to be valid.  
INSTALLING THE MAX® 4400  
As a temporary fix, disconnect one  
or more pieces of equipment. Ask  
your dealer about additional PANA-  
MAX products that may be  
required.  
NOTE: The MAX® 4400 and the  
connected equipment must be  
indoors and in the same building.  
MAX® 4400 PRODUCT SPECIFICATIONS  
Ground OK LED -  
Unsafe Voltage - (red) when lit, indicates  
that incoming voltage is unsafe and the  
surge protector has disconnected the  
power to protect your equipment.  
Switched Outlets Pushbutton  
one of two triggers that can  
turn-on or turn-off the switched  
outlets. Leave this switch in the  
ON position if the DC trigger is  
being used.  
-
Voltage Trigger LED  
-
Switched Outlets LED  
Indicates that the  
Switched Outlets  
are on.  
-
(green) indicates that  
the wall outlet is  
properly grounded.  
(green) when lit, indicates  
that the DC Trigger is  
active (ON).  
AC Surge Protection  
Line Voltage……………......……………….120V, 50/60 Hz  
Maximum Current Rating…….......................………….20A  
UL 1449 Surge Suppression Rating…...................……330V  
Protection Modes…………………….......…..L-N, L-G, N-G  
Initial Clamping Level………........….200V Peak, 141V RMS  
Response Time………...........................……………...<1ns  
Joule Rating……………………............………1650 Joules  
Peak Impulse Current……...........................………52,000A  
EMI/RFI Noise Filtration……......…. 50dB (100KHz - 1 MHz)  
Catastrophic Surge Circuit……......................………….YES  
Thermal Fusing……...................……………………….YES  
Over/Under Voltage Protection……....................………YES  
Always-on Convenience Outlet  
-
10 Ft. AC Power Cord  
-
Over-voltage shutoff threshold…………..............…147V  
8
Always-On Outlets - Four  
Always-On outlets provide  
a constant power source.  
Ground Lug -  
Switched Outlets  
-
Four outlets controlled  
by one of the two trig-  
ger sources.  
Voltage Sense Trigger  
Turn-On Delay  
20A Circuit Breaker - will  
automatically “open” when  
the current load is greater  
than 20 Amperes. When  
this happens, the circuit  
breaker can be manually  
reset by simply pushing  
the reset button, which  
will have “popped” out.”  
Provides a common  
grounding point for  
equipment with  
separate ground  
Input - 3.5mm Mini-  
Plug jack. Connect to a  
remote trigger device  
that provides 12VDC to  
trigger a startup/ shut-  
down sequence. This is  
the second trigger that  
will turn-on or turn-off  
the switched outlets.  
Switch - Provides  
a 10-second  
Turn-On delay  
for the switched  
outlets.  
Under-voltage shutoff threshold……..................……84V 6  
DC Trigger  
Connection………………….............……3.5mm mini-plug  
Voltage and Polarity……..................5-30VDC, bi-directional  
Current Requirement….......................…………...…>10mA  
INS4400 REV. A  
11/02  

Polk Audio polkaudio the speaker specialists DB400 User Manual
PHL Audio 1660 User Manual
Philips 166V3L User Manual
Panasonic Cordless Phone With Answering Machine KX TG7643 User Manual
NEC Electronics America Car Video System NDA 30135 User Manual
Nady Systems 351VR User Manual
Metz 28 AF 4 C User Manual
Lochinvar EBN SUB 05 User Manual
LG Electronics LG Lifes Good Car Video System E1940S User Manual
JVC LYT0087 001B User Manual