Elinchrom STYLE 400 User Manual

elinca sa switzerland www.elinchrom.com  
Operating Manual  
Style FX 100/400  
Deutsch  
Elinca S.A Style FX 01.01.2007 DE (73276) Printed in Switzerland  
190/260V  
Introduction  
The Elinchrom Style FX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland  
Dear Photographer,  
Thank you for buying your Style FX compact flash unit.  
All Elinchrom products are manufactured using the most advanced technology. Carefully selected  
components are used to ensure the highest quality and the equipment is submitted to many controls  
both during and after manufacture. We trust that it will give you many years of reliable service.  
All Style FX flash units are manufactured for the studio and location use of professional  
photographers. Only by observance of the information given, can you secure your warranty, prevent  
possible damage and increase the life of this equipment.  
Style 100FX - 400FX  
The quality of light and exceptional performance is the result of long research, application of  
demanding principles, the long experience of ELINCHROM in lighting products for the studio  
and the utilization of the latest technology in this area.  
Totally integrated to the range of the ELINCHROM flashes, the Style 100FX - 400FX units  
maintain the traditional look and function that is ELINCHROM.  
The control provides continuously variable adjustment of the modelling lamp and the flash  
power with precision over 5 f-stop, from full power 1/1 to 1/16 th.  
FCC Class B Compliance Statement  
Note:  
This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part  
15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations.  
These limits are designed to provide reasonable protection against harmful interference in a residential  
installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and  
used in accordance with the instruction manual, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular installation. If this equipement  
does not cause harmful interferences to radio or television reception, which can be determined by turning the  
equipement off and on, the user is encouraged to correct the interferences by one or more of the following  
measures:  
- Reorient or relocate the receiving antenna.  
- Increase the separation between the equipement and receiver.  
- Connect the equipement into an outlet on a circuit different from that to which the receiver is connected.  
- Consult the dealer or an experienced radio/TV technician for help.  
ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modifications of  
this equipement or the substitution or attachment of connecting cables and equipement other than those specified  
by ELINCA S.A. The correction of interference caused by such unauthorised modification, substitution or  
attachment will be the responsibility of the user.  
2
Declaration of conformity  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause  
undesired operation.  
Product name:  
Trade name:  
Professional Studio Flash unit  
ELINCHROM  
Model number(s):  
Style FX 100/400  
Name of responsible party: Elinca S.A  
Av. De Longemalle 11  
1020 Renens / Switzerland  
Phone :  
Fax:  
+41 21 637 2677  
+41 21 637 2681  
We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number  
specified above was tested conforming to the applicable FCC rules, and that all the necessary steps  
have been taken and are in force to assure that the production units of the same equipement will  
continue to comply with the Comissions requirements.  
Disposal and recycling  
This device has been manufactured to the highest possible degree from materials  
which can be recycled or disposed of in a manner that is not enviromentally  
damaging. The device may be taken back after use to be recycled, provided that is  
turnedinaconditionthatistheresultofnormaluse.Anycomponentsnotreclaimed  
will be disposed of in a environmentally acceptable manner.  
If you have any question on disposal, please contact your local office or your local ELINCHROM  
agent (check our website for a list of all ELINCHROM agents world wide).  
CE marking  
The shipped version of this device complies with the requirements of ECC directives  
89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive».  
Notational Conventions  
The meaning of the symbols and fonts used in this manual are as follows:  
Pay particular attention to text marked with this symbol.  
Failure to observe this warning endangers your life, destroys the device, or may  
damage other equipement  
!
Supplementary information, remarks, and tips follow this symbol.  
Text which follows this symbol describes activities that must be performed in the  
order shown.  
i
«Quotation marks» indicate names of chapters or terms  
3
Safety notice  
According to safety regulations, we draw your attention to the fact that these  
electronic flash units are not designed for use outdoors, in damp or dusty conditions and should  
not be used after being exposed to sudden temperature changes causing condensation. They must  
always be connected to an earthed (grounded) mains supply.  
On no account should any object be inserted into the ventilation holes.  
The units may retain an internal charge for a considerable time even though disconnected from the  
power supply.  
• Do not use in restricted areas (like hospitals, etc.).  
• Do not use in explosive environnements.  
Flash Tubes and Modelling lamps  
• Flash tubes and modelling lamps in use are very hot!  
• Never touch a flash tube or lamp before the unit cooled down and is disconnected from  
the mains (min 30mn).  
• Do not fire flashes from short distance (less than 1m) directed to a person and avoid looking  
directly into the flashlight!  
• Keep (min 1m) distance to flammable materials.  
• Keep generally distance to operating units.  
Transport  
Transport the flash unit with care and only in its original packaging or another corresponding  
packaging fit to protect it against knocks and jolts.  
Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing  
from mains supply before packaging and transportation.  
• Never drop the flash unit (danger of glass breakage)  
Power cable  
To guarantee safe operation, use the cable supplied.  
• The cable has to be HAR-certified or VDE-certified. the mark HAR or VDE will appear on the outer  
sheat.  
• The cable set must be selected according to the rated current for your flash unit.  
• Do not use a spider box to connect one or more flash units.  
• Flash systems store electrical energy in capacitors by applying high voltage.  
• For your safety, never open or disassemble your flashes.  
• Only an authorised service engineer should open or attempt to repair the units.  
• Internal defect charge capacitors may explode whilst the unit is in use, neve  
switch on a proper working flash unit.  
!
4
Before you start !  
The Style FX are adapted for operation on 190-260V/50-60Hz.  
Before connecting for the first time, check to make sure that your modelling lamp coincides  
with the voltage line.  
They must always be connected to an earthed ( grounded) mains supply.  
All Style FX units have a bayonet mount and locking ring reflector fitting, for fixing all Elinchrom and  
Prolinca accessories.  
Mount the unit securely to a suitable stand or support.  
Remove the black protective cover (note: first turn the locking ring A as shown, then rotate the  
black cap cover B in the same direction). Fitting a reflector or accessory is the reverse of this action.  
DO NOT operate the unit without first removing the black protective cover.  
Operating instructions  
1.Check that the modelling lamp voltage is correct.  
2.Check that the mains switch (3) is in the OFF ("O" position).  
3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET  
4.Connect the synchro cord to the socket (6).  
5.Using the mains SWITCH (3) and switch the unit ON ("I" position).  
6.Select the power with the touch pad (11 - 12)  
12  
11  
6
1
3
handle  
A/ locking ring  
B/ protective  
cover  
(26124)  
C/ tilthead with locking  
umbrella holder  
5
Control Panel  
13 14 15 18  
9
10  
7
8
5
12  
11  
4
2
6
3
16  
1
21 19 17  
20  
Overview of controls  
1.Mains inlet socket  
2.Mains fuse (slow blow)  
12. + Power adjustment in 1/10 f-stops  
13. Modelling lamp switch  
(on/off free or prop)  
14.+ Modelling power control  
15. - Modelling power control  
16. Tilt head clamp  
17. Knurled clamp screw  
18. Handle  
19. Stand 5/8-inch socket  
20. Umbrella tube (only for EL  
umbrellas, diameter 7 mm)  
21.Supplementary locking for others  
umbrellas  
3.Mains Illuminated on/off switch  
4.Modelling fuse (fast blow)  
5.Open-flash  
6.Synchro-sockets, Amphenol + jack 3.5 mm  
7.Digital power display and  
charge/discharge indicator  
8. Acoustic recharging signal (Beep)  
9. Slave cell switch on/off  
10. Photocell receptor  
11. Power adjustment in 1/10 f-stops, with  
ADF  
6
Mains Supply  
With the MAINS SWITCH (3) switched off ("O" position), firmly push in the plug  
of the original ELINCHROM mains cord into the mains socket (1).  
Mains Switch  
The switch should light up when the compact is switched on ("I" position).  
(Switch off before removing the mains cord).  
Troubleshooting  
If the on/off switch (3) is ON ("I" position) but not illuminated,  
switch off the unit and check the mains fuse (2).  
If failed replace with the correct fuse and switch ON the unit.  
This unit is protected by a thermal circuit breaker to avoid overheating.  
Should this occur, the unit turns off automatically and cannot be fired.  
After a break for cooling, the flash will be ready again for operation.  
See page 11: Troubleshooting  
This equipment is not user serviceable and contains high voltages which are dangerous.  
In the event of failure, please return the unit to an authorized Elinchrom service station.  
Mains Fuse  
Standard type 5 x 20 mm, (use only tempered fuse)  
8 AT (code 19022) for Style 100FX and Style 400FX  
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and  
turn the fuse holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately  
upon reconnection, return the unit to an ELINCHROM service centre for a check-up.  
(Please don't forget to check the correct rating of the fuse !).  
Fuse for modelling light  
Fast type 5 x 20mm, 4 AF  
Switch off the unit and replace the blown fuse with a new one of the correct rating.  
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore  
the flash tube.  
Modelling fuse  
4
Mains socket  
1
Mains fuse  
(Only tempered)  
2
3
Mains switch  
7
Modelling Light  
The touch pad (14) controls the modelling lamp on/off and the proportional light.  
Select the power with the touch pad (15). The modelling light output (100%) is achieved when  
the power value is set to maximum.  
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the  
light output is proportional to the selected flash power.  
For all types of Style FX compact flash units, use maximum 200 - 250W modelling lamps  
Modelling lamps and fuse (230V Version)  
Unit  
Modelling lamp  
100W krypton  
100W krypton  
150W halostar  
200W halogen  
Code  
23002  
23002  
23035  
23034  
Socket  
E27  
Fuse  
2.5AF  
2.5AF  
2.5AF  
2.5AF  
Code  
19033  
19033  
19033  
19033  
Style 100FX  
Style 400FX  
Option:  
E27  
E27  
Option:  
GX 6,35  
Note: lamp socket adapter E27 to GX 6.35, code 23101  
This adaptator allows the use of the halogen lamp 200W, GX 6.35 (code 23034) in the Style 100 FX and  
400 FX units.  
230V Modelling lamp options:  
23033  
23101  
23035  
If the modelling lamp does not illuminate, this may be due to the following:  
1. The filament is broken after long use *(replace lamp and fuse)  
2. The filament is broken after shock *(replace lamp and fuse)  
3. An internal component failure, *(return the unit to customer service)  
* Action required:  
14  
15  
15  
On/Off  
Increase  
Decrease  
proportional  
8
Digital power display  
The actual flash power is shown in a f-stop compatible format.  
The power range is 5 f-stops. The digital display, provides continuous power indication of the flash  
and modelling lamp. The controls cover a continuous output range from full power 1/1 to 1/16th in  
1/10th, f-stop intervals.  
During charging or discharging, the display "flashes".  
Note:  
The "Style 100 FX and 400 FX" units have an integrated discharge system, protected by a thermic switch.  
To avoid overheating, lower power settings of more than 2f-stop, can be discharged manually by releasing the  
flash with the «Test» touch button.  
Photocell  
The photocell is actived when the green LED (on the touch pad 9) is illuminated.  
When switched ON, the unit can be remotely triggered by another flash unit !  
The Style FX photocell is specially designed to work under ambiant light conditions in your studio.  
Direct light or other strong light sources may reduce the sensitivity of the cell.  
In difficult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord  
(extensions available) solves most problems.  
Power display  
9 Cell  
10  
Photocell  
receptor  
5
Test and ready  
Modellling  
light controls  
9
Cordless flash control  
EL-Skyport triggers flashes without sync cords over a distance of  
approximately 100 m. Further detailed information please find under  
EL-Skyport Universal Set  
(19360)  
Universal receiver  
Transmitter  
Sychronisation socket  
The standard socket 3.5 mm mini-jack (6).  
N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets.  
ELINCHROM uses the low voltage (5V) for security reasons.  
Test and Ready  
Open flash "Test"  
Having pressed the touch pad to release a flash, the green «READY» light will  
appear again once the unit is recharged. If the green light does not appear the  
charge system could be defective.  
5
Please contact and send to an authorized Elinchrom service.  
Beep  
8
Audible recharge signal  
Select the function with the touch pad (8), the green indicator appears.  
Once recycled an acoustic signal indicates that the compact unit is ready.  
10  
Troubleshooting  
1. The mains switch (3) is ON ("I" position), but does not light up:  
• Switch OFF the unit and change the mains fuse (2)  
• Use only time-lag fuse (16 AT), corresponding to the Style FX model  
2. The switch (3) is lit, the open flash ready is lighting up but does not function.  
• The flashtube in the flashhead may be faulty  
• You cannot change the flashtube by yourself! => please return the unit to an authorised  
Elinchrom service.  
3. The ON/OFF switch (3) is lit but the open flash signal (6) is not lit  
Temporary break for overheating, caused by fast flash sequences or ventilation  
slots obturated  
• Fan cooling defective => the unit turns off automatically and cannot be fired any  
more. After a break for cooling, the flash is ready again for operation.  
• If after several minutes of break for cooling the ready signal (6) is not lit, the cause  
could be a component failure. However, high voltage may remain on the capacitor  
circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit  
to an authorised Elincrom station.  
Training with Elinchrom lighting  
The Beginner’s Guide To Light /  
72404  
Only in English available.  
Your DVD Guide to better pictures, show  
how easy studio photography can be.  
Learn about flash units and why studio  
flash is just the better light source for  
portrait and universal photography.  
Setting up and controlling flash lights and  
how to use umbrellas, softboxes, snoots  
and grids. Have a look and enjoy the  
passion of photography. Presented by  
Chris Burfoot.  
11  
Features  
• Mains switch  
• Controls for: modelling on/off, cell on/off, acoustic signal on/off.  
• Flash and modelling power control.  
• «X» synchro jack socket 3,5 mm.  
• Socket for Plug-In remote control.  
• Mains inlet socket and two fuses (Mains and modelling).  
• Locking bayonet ring for accessory and reflector fitting  
• Tilthead whit 5/8" - inch stand socket  
• Thermal safety  
• Halogen modelling lamp 100W, with E27 fitting, or optional alternative  
*200W/GX6.35 with adaptator code 23101.  
• Silent fan cooling  
• Auto dumping function. Automatic discharge of flash power  
• Central umbrella tube plus external fitting  
• Acoustic recharging signal  
• Mains cable  
• Synchro cord of 5m (jack 3.5mm plug)  
• Protective cover  
Total compatibility with all Elinchrom accessories  
• Very fast recycling time  
• Very short flash duration  
Technical data  
100FX  
400FX  
Flash power  
J(Ws)  
V
100  
400  
Power supply  
200/260  
32,5  
200/260  
64,5  
F-stop, 1m, 100 ISO, with reflector 48°  
Control range  
J(Ws) 6.25-100  
25-400  
0,3-1,2  
1/900  
1/550  
100  
Recycling time (230 V)  
Flash duration (t 0,5) 1/1  
(t 0,5) 1/16  
s
s
0,2-0,5  
1/1800  
1/1150  
100  
s
Modelling output  
W
V
Voltage across sync cable  
5
5
Connected load A/VA  
(W)  
6.3/1638  
6.3/1638  
Radio interference suppressiv CE-IEC 491  
Dimension length x diam.  
Weight  
cm  
kg  
21x14  
1,55  
21x14  
1,9  
Tolerances and specifications conforming to IEC and CE standards. Technical data subject to change  
without notice.  
12  
13  
Single units do not include Reflectors  
-
Product range and specifications subject to change. No guarantee for misprints.  
GUARANTEE  
This ELINCHROM product will be repaired free of charge by the vending agent if during a period  
of 24 months from date of purchase its working order is impaired through a manufacturing or  
material defect. The faulty product should be immediately sent to the authorized dealer or ELINCA  
agent. This guarantee is not valid for equipment which has been misused, dismantled, modified  
or repaired by persons not belonging to the ELINCA distribution network. It does not cover flash  
tubes, lamps and the normal ageing of capacitors. No responsibilities can be accepted for damage  
resulting from unsatisfactoıy operation of the equipment, such as wasted film or other expenses.  
Please „register“ your Elinchrom product online, under  
i
In case you cannot register your Elinchrom unit via internet, please fill in the  
Guarantee card and post it to Elinca.  
Please return this registratioin card directly to  
Diese Registrierkarte bitte direkt zurücksenden an  
Veuillez retourner cette carte d’enregistrement directement à  
Vi preghiamo di far pervenire questa cartolina di iscrizione direttamente a  
Por favor envie esta carta de registro directamente  
:
:
:
:
:
elinca sa  
P.O. Box 458  
Avenue de Longemalle 11  
CH-1020 Renens  
Switzerland  
Elinchrom model  
:
:
:
:
:
Elinchrom modèle  
Elinchrom modell  
Modello di Elinchrom  
Modelo de Elinchrom  
N°  
Date of purchase  
Datum des Kaufs  
La date d’achat  
La data di acquisto  
La fecha de la compra  
:
:
:
:
:
Dealer  
Händler  
Négociant  
Il distributore  
El comerciante  
:
:
:
:
:
Your full name and address  
Ihr voller Name und redet an  
Votre nom complet et adresse  
Il suo nome pieno ed indirizza  
Su nombre y apellidos y dirige  
:
:
:
:
:
14  

Ativa PET720 User Manual
Baby Jogger Car Stereo System User Manual
Bosch Appliances MUM 4620 UC User Manual
Canon ELPH510HSSIL User Manual
Clarion DXZ676USB User Manual
Hamilton Beach 840072000 User Manual
JVC EXAD LVT1373 001A User Manual
JVC GR D90 User Manual
JVC GR D370EK User Manual
JVC GR SXM248 User Manual