York 10 Seer 50hz R22 User Manual

339293-YTG-C-0208  
DESCRIPTION  
The HRA Series condensing unit is the outdoor part of a ver-  
satile system of air conditioning. It is designed to be custom  
matched with one of UPG’s complete line of evaporator sec-  
tions, each designed to serve a specific function. Matching  
Air Handlers are available for upflow, downflow or horizontal  
applications to provide a complete system. Electric Heaters  
are available if required. Add-On coils are available for use  
with upflow, downflow or horizontal furnaces and air handlers.  
FEATURES  
QUALITY CONDENSER COILS - The coil is constructed  
TECHNICAL GUIDE  
of enhanced copper tube and aluminum fins.  
COIL PROTECTION - Coils are protected from damage by  
a polymer mesh applied between the coil face, and a PVC  
coated steel coil guard.  
SPLIT-SYSTEM HEAT PUMPS  
10 SEER – R-22  
PROTECTED COMPRESSOR - The compressor is inter-  
nally protected against high pressure and temperature.  
This is accomplished by the simultaneous operation of  
high pressure relief valve and a temperature sensor which  
protects the compressor if undesirable operating condi-  
tions occur. A liquid line filter-drier further protects the  
compressor.  
MODELS:  
10 SEER 50 HZ R22  
H*RA018S78 THRU H*RA036S78 (1 PH)  
(1.5 THRU 3 NOMINAL TONS)  
DURABLE FINISH - Cabinet is made of pre-painted steel.  
The pre-treated flat galvanized steel provides a better  
paint to steel bond, which resists corrosion and rust creep.  
Special primer formulas and matted-textured finish insure  
less fading when exposed to sunlight.  
LOWER INSTALLED COST - Installation time and costs  
are reduced by easy power and control wiring connections.  
Discharge line heat exchanger knockouts are provided, if  
required. Available in sweat connect models only. The unit  
contains enough refrigerant for matching indoor coils and  
15 feet of interconnecting piping. The small base dimen-  
sion means less space is required on the ground or roof.  
TOP DISCHARGE - The warm air from the top mounted  
fan is blown up away from the structure and any landscap-  
ing. This allows compact location on multi-unit applica-  
tions.  
LOW OPERATING SOUND LEVEL - The upward air flow  
carries the normal operating noise up away from the living  
area. The rigid top panel effectively isolates any motor  
sound. Isolator mounted compressor and the rippled fins of  
the condenser coil muffle the normal fan motor and com-  
pressor operating sounds.  
LOW MAINTENANCE - Long life permanently lubricated  
Due to continuous product improvement, specifications  
are subject to change without notice.  
motor-bearings need no annual servicing.  
EASY SERVICE ACCESS - Fully exposed refrigerant con-  
nections, a single panel covering the electrical controls  
and the molex plug in the control box connecting the con-  
denser fan, make for easy servicing of the unit.  
SECURED SERVICE VALVES - Secured re-usable ser-  
vice valves are provided on both the liquid and vapor  
sweat connections for ease of evacuating and charging.  
FACTORY TESTED - to verify system operation and con-  
trol functioning before shipment.  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
339293-YTG-C-0208  
COOLING CAPACITY - With Air Handler Coils  
AIR HANDLER  
COOLING  
COIL  
MODEL  
UNIT MODEL  
NET MBH  
ELECTRIC  
HEAT KW  
RATED  
CFM  
MODEL  
W
KW  
TOTAL SENS.  
1 PHASE HRA / FRP (SINGLE PHASE)  
H1RA018S78  
H1RA024S78  
H1RA030S78  
H1RA036S78  
F2RP024N93  
F2RP024N93  
F2RP036N93  
F2RP036N93  
5,7.5,10  
5,7.5,10  
18  
18  
21  
21  
650  
850  
18.1  
23.4  
29.6  
34.3  
12.9  
16.8  
20.6  
25.6  
1.86  
2.87  
3.57  
3.86  
5,7.5,10,15  
5,7.5,10,15  
1000  
1250  
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.  
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.  
COOLING PERFORMANCE  
AIR TEMP ON CONDENSER  
SUCT. T/P  
@ COMPR.  
MODEL  
75°F  
95°F  
115°F  
MBH  
125°F  
MBH  
TEMP.  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
PSIG  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
MBH  
13.1  
14.8  
16.5  
18.4  
21.3  
24.1  
26.7  
29.6  
28.0  
31.5  
35.1  
38.9  
30.6  
34.4  
38.3  
38.9  
KW  
1.36  
1.42  
1.48  
1.55  
1.59  
1.68  
1.77  
1.85  
2.31  
2.44  
2.52  
2.62  
3.14  
3.28  
3.42  
2.62  
MBH  
13.1  
14.8  
16.5  
18.4  
17.7  
20.1  
22.3  
24.9  
24.4  
27.5  
30.7  
34.2  
27.0  
30.4  
33.9  
34.2  
KW  
1.36  
1.42  
1.48  
1.55  
1.93  
2.04  
2.16  
2.27  
2.65  
2.78  
2.91  
3.04  
3.48  
3.64  
3.81  
3.04  
KW  
1.46  
1.55  
1.62  
1.71  
2.14  
2.27  
2.40  
2.55  
2.86  
3.02  
3.17  
3.34  
3.79  
3.98  
4.17  
3.34  
KW  
1.52  
1.61  
1.69  
1.78  
2.23  
2.38  
2.53  
2.67  
2.96  
3.31  
3.48  
3.48  
3.89  
4.10  
4.30  
3.48  
10.6  
12.8  
13.7  
15.2  
14.7  
16.7  
18.9  
21.1  
20.1  
22.8  
25.9  
28.8  
23.1  
26.1  
29.1  
28.8  
9.3  
10.6  
12.2  
13.7  
13.3  
15.1  
17.1  
19.4  
18.0  
23.4  
23.4  
26.3  
21.0  
23.7  
26.6  
26.3  
H1RA018S78  
H1RA024S78  
H1RA030S78  
H1RA036S78  
1. For condensing unit only. Does not include effect of evaporator motor power or heat.  
2. Performance based on 15°F superheat and 15°F sub-cooling at condensing unit.  
a. Increase capacity 1% for each 2°F increase in sub-cooling.  
b. Decrease capacity 1% for each 2°F decrease in sub-cooling.  
3. Sub-cooling in excess of 20°F may result in excessively high condensing temperature with air on condenser above 115°F Maximum  
recommended condensing temperature is 140°F.  
Unitary Products Group  
3
339293-YTG-C-0208  
ACCESSORIES  
Refer to Price Manual for specific model numbers.  
SOUND RATINGS  
UNIT MODEL  
(dBA)  
Compressor Blanket - Designed to further reduce the nor-  
018  
024  
030  
036  
76  
78  
82  
82  
mal operating sound.  
Hard Start Kit (Single Phase Units) - provides required  
starting torque for use with thermal expansion valve.  
Outdoor Thermostat - 2TD06700124 - Consists of an  
adjustable outdoor thermostat and relay in a vented enclo-  
sure. It provides additional second stage control of the sup-  
plemental resistance heat.(Balance Point Control)  
* Rated in accordance with ARI 270-95 Standards.  
TYPICAL INSTALLATION - H*RA018S78 THRU 036S78 (1 PH)  
MINIMUM 18” SERVICE ACCESS  
CLEARANCE ON ONE SIDE  
THERMOSTAT  
TO FURNACE OR  
AIR HANDLER  
TERMINAL BLOCK  
60” OVERHEAD  
CLEARANCE  
WEATHERPROOF  
DISCONNECT  
SWITCH  
NEC CLASS 1 WIRING  
NEC CLASS 2 WIRING  
10” CLEARANCE  
COIL AREA  
TO INDOOR COIL  
SEAL OPENING(S) WITH  
PERMAGUM OR EQUIVALENT  
NOTE: ALL OUTDOOR WIRING MUST  
BE WEATHERPROOF.  
CONTROL ACCESS PANEL  
TYPICAL FIELD WIRING - 1 PH APPLICATION (018S78 - 036S78)  
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES  
POWER WIRING  
POWER WIRING  
230-1-50  
24 VOLT CONTROL WIRING  
MINIMUM 18 GA. WIRE  
(NEC CLASS 2)  
CONTROL WIRING  
FACTORY WIRING  
FURNACE OR AIR HANDLER TERMINAL BLOCK  
*
TERMINAL W IS ONLY  
REQUIRED ON SYSTEMS  
WITH HEAT.  
C
Y
R
G
W
CONTACTOR  
TERMINALS  
GND.  
LUG  
*
COIL  
Y
R
G
W
ROOM THERMOSTAT  
CONDENSING UNIT  
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.  
4
Unitary Products Group  
339293-YTG-C-0208  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H1RA018S78A  
F2RP024  
500  
IDCFM  
650  
80  
800  
CONDENSING  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
85  
80  
70  
85  
70  
85  
80  
70  
72  
67  
57  
72  
67  
57  
72  
67  
57  
18.3  
10.6  
1.55  
17.8  
10.6  
1.76  
17.3  
10.6  
1.79  
16.0  
10.0  
1.99  
14.6  
9.4  
18.1  
10.8  
1.55  
17.2  
10.7  
1.74  
16.3  
10.5  
1.75  
14.7  
10.0  
1.94  
13.1  
9.5  
16.5  
10.5  
1.53  
15.4  
10.2  
0.95  
14.2  
9.8  
18.4  
11.0  
1.71  
18.0  
11.3  
1.95  
17.6  
11.6  
1.95  
16.5  
11.4  
2.19  
15.3  
11.2  
2.18  
13.7  
11.1  
2.28  
18.2  
11.6  
1.71  
17.5  
11.7  
1.93  
16.8  
11.8  
1.92  
15.3  
11.4  
2.14  
13.8  
11.0  
2.12  
11.6  
10.0  
2.21  
17.2  
11.9  
1.69  
16.1  
11.6  
1.90  
15.0  
11.4  
1.88  
13.3  
10.7  
2.09  
11.7  
10.0  
2.07  
9.9  
18.4  
11.4  
1.68  
18.2  
12.0  
1.95  
17.9  
12.5  
1.92  
17.0  
12.7  
2.19  
16.0  
12.9  
2.16  
14.3  
12.7  
2.26  
18.3  
12.4  
1.67  
17.8  
12.8  
1.93  
17.3  
13.1  
1.89  
15.9  
12.8  
2.14  
14.4  
12.5  
2.10  
12.1  
11.5  
2.19  
17.8  
13.3  
1.66  
16.8  
13.1  
1.90  
15.8  
12.9  
1.85  
14.1  
12.2  
2.09  
12.3  
11.5  
2.04  
10.4  
10.6  
2.13  
75  
85  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
95  
S.C.  
K.W  
1.71  
12.6  
9.2  
T.C.  
105  
115  
125  
S.C.  
K.W  
1.90  
11.0  
8.5  
T.C.  
S.C.  
K.W  
2.01  
13.0  
9.4  
1.94  
11.1  
8.5  
1.90  
9.3  
T.C.  
S.C.  
7.8  
9.2  
K.W  
2.11  
2.04  
1.98  
2.15  
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87°F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Unitary Products Group  
5
339293-YTG-C-0208  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H1RA024S78A  
F2RP024  
650  
IDCFM  
850  
80  
1050  
80  
CONDENSER  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
85  
80  
70  
85  
70  
85  
70  
72  
67  
57  
72  
67  
57  
72  
67  
57  
26.4  
15.4  
2.15  
25.4  
15.3  
2.31  
24.4  
15.3  
2.47  
22.5  
14.7  
2.62  
20.6  
14.2  
2.76  
17.8  
13.3  
2.89  
25.3  
15.6  
2.11  
23.9  
15.1  
2.26  
22.5  
14.6  
2.40  
20.1  
13.8  
2.53  
17.7  
13.0  
2.65  
15.2  
12.4  
2.78  
24.0  
15.4  
2.08  
21.8  
14.4  
1.16  
19.6  
13.4  
2.31  
17.6  
12.7  
2.44  
15.6  
11.9  
2.56  
13.3  
11.4  
2.69  
26.6  
16.2  
2.17  
25.7  
16.4  
2.33  
24.9  
16.6  
2.50  
23.2  
16.4  
2.66  
21.5  
16.3  
2.81  
18.7  
15.4  
2.94  
25.7  
16.7  
2.13  
24.6  
16.6  
2.28  
23.4  
16.6  
2.44  
21.1  
15.9  
2.57  
18.8  
15.2  
2.70  
15.9  
14.3  
2.82  
24.6  
16.8  
2.10  
22.8  
16.2  
2.23  
20.9  
15.7  
2.35  
18.6  
14.7  
2.47  
16.3  
13.8  
2.59  
14.0  
13.1  
2.72  
26.7  
16.9  
2.18  
26.1  
17.4  
2.36  
25.4  
17.9  
2.53  
23.9  
18.1  
2.70  
22.4  
18.3  
2.86  
19.5  
17.4  
2.99  
26.1  
17.8  
2.15  
25.2  
18.2  
2.31  
24.3  
18.5  
2.47  
22.1  
17.9  
2.61  
19.8  
17.3  
2.74  
16.7  
16.1  
2.85  
25.2  
18.2  
2.12  
23.7  
18.1  
2.26  
22.2  
17.9  
2.39  
19.6  
16.8  
2.51  
16.9  
15.6  
2.62  
14.7  
14.7  
2.75  
75  
85  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
95  
S.C.  
K.W  
T.C.  
105  
115  
125  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87°F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
6
Unitary Products Group  
339293-YTG-C-0208  
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H1RA030S78A  
F2RP036  
650  
IDCFM  
850  
80  
1050  
CONDENSER  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
85  
80  
70  
85  
70  
85  
80  
70  
72  
67  
57  
72  
67  
57  
72  
67  
57  
26.4  
15.4  
2.39  
25.4  
15.3  
2.67  
24.4  
15.3  
2.71  
22.5  
14.7  
2.98  
20.6  
14.2  
3.00  
17.8  
13.3  
3.13  
25.3  
15.6  
2.35  
23.9  
15.1  
2.62  
22.5  
14.6  
2.64  
20.1  
13.8  
2.89  
17.7  
13.0  
2.88  
15.2  
12.4  
3.02  
24.0  
15.4  
2.32  
21.8  
14.4  
1.40  
19.6  
13.4  
2.55  
17.6  
12.7  
2.80  
15.6  
11.9  
2.80  
13.3  
11.4  
2.93  
26.6  
16.2  
2.53  
25.7  
16.4  
2.82  
24.9  
16.6  
2.86  
23.2  
16.4  
3.14  
21.5  
16.3  
3.17  
18.7  
15.4  
3.30  
25.7  
16.7  
2.49  
24.6  
16.6  
2.76  
23.4  
16.6  
2.80  
21.1  
15.9  
3.05  
18.8  
15.2  
3.05  
15.9  
14.3  
3.18  
24.6  
16.8  
2.46  
22.8  
16.2  
2.71  
20.9  
15.7  
2.71  
18.6  
14.7  
2.95  
16.3  
13.8  
2.95  
14.0  
13.1  
3.08  
26.7  
16.9  
2.56  
26.1  
17.4  
2.93  
25.4  
17.9  
2.91  
23.9  
18.1  
3.27  
22.4  
18.3  
3.24  
19.5  
17.4  
3.37  
26.1  
17.8  
2.53  
25.2  
18.2  
2.88  
24.3  
18.5  
2.85  
22.1  
17.9  
3.18  
19.8  
17.3  
3.12  
16.7  
16.1  
3.23  
25.2  
18.2  
2.50  
23.7  
18.1  
2.83  
22.2  
17.9  
2.77  
19.6  
16.8  
3.08  
16.9  
15.6  
3.00  
14.7  
14.7  
3.13  
75  
85  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
95  
S.C.  
K.W  
T.C.  
105  
115  
125  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87°F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Unitary Products Group  
7
COOLING PERFORMANCE DATA  
AIR CONDITIONER MODEL NO.  
INDOOR COIL MODEL NO.  
H1RA036S78A  
F2RP036  
1050  
IDCFM  
1250  
80  
1450  
80  
CONDENSER  
ENTERING AIR  
TEMPERATURE  
ID DB (°F)  
ID WB (°F)  
T.C.  
85  
80  
70  
85  
70  
85  
70  
72  
67  
57  
72  
67  
57  
72  
67  
57  
38.7  
23.4  
3.30  
37.4  
23.5  
3.74  
36.0  
23.6  
3.80  
32.6  
22.6  
4.17  
29.2  
21.5  
4.16  
25.5  
20.3  
4.29  
36.8  
23.5  
3.25  
34.8  
24.0  
3.65  
32.7  
24.5  
3.67  
29.1  
22.1  
4.00  
25.5  
19.6  
3.95  
22.4  
18.8  
4.12  
35.0  
23.4  
3.21  
31.9  
22.2  
1.95  
28.7  
21.0  
3.51  
25.5  
19.6  
3.85  
22.3  
18.2  
3.81  
19.6  
17.4  
3.99  
39.1  
24.4  
3.59  
37.7  
24.7  
4.06  
36.4  
25.0  
4.09  
33.2  
24.3  
4.53  
30.1  
23.6  
4.50  
26.2  
22.3  
4.65  
34.7  
24.8  
3.54  
34.1  
25.2  
4.00  
33.5  
25.6  
3.99  
29.9  
23.6  
4.36  
26.3  
21.6  
4.27  
22.8  
20.5  
4.43  
35.6  
24.8  
3.50  
32.6  
23.9  
3.90  
29.6  
22.9  
3.83  
26.3  
21.5  
4.21  
23.1  
20.0  
4.12  
20.0  
18.9  
4.29  
39.4  
25.4  
3.48  
38.1  
25.9  
4.00  
36.7  
26.4  
3.99  
33.9  
26.1  
4.49  
31.0  
25.7  
4.45  
26.9  
24.3  
4.61  
32.5  
26.1  
3.43  
33.4  
26.4  
3.94  
34.3  
26.7  
3.92  
30.7  
25.2  
4.32  
27.0  
23.6  
4.19  
23.1  
22.2  
4.35  
36.2  
26.2  
3.39  
33.4  
25.5  
3.84  
30.5  
24.8  
3.76  
27.2  
23.3  
4.17  
23.8  
21.8  
4.04  
20.4  
20.3  
4.20  
75  
85  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
95  
S.C.  
K.W  
T.C.  
105  
115  
125  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
T.C.  
S.C.  
K.W  
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.  
Multipliers for determining the performance with other indoor sections.  
NOTE: For dry bulb temperatures different than those listed (between 73-87°F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the  
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.  
Subject to change without notice. Printed in U.S.A.  
339293-YTG-C-0208  
Copyright © by Unitary Products Group. 2008. All rights reserved.  
Supersedes: 339293-YTG-B-0108  
Unitary  
Product  
Group  
5005  
York  
Drive  
Norman  