Sanyo Ks2462r User Manual

INSTRUCTION MANUAL  
COOL/DRY Model  
KS2462R  
Split System Air Conditioner  
In order to protect the environment, this air conditioner uses the new refrigerant R410A.  
SaveThese Instructions!  
Printed on Recycled Paper  
Pub. OI-85464189508000  
©SANYO 2002  
Features  
This air conditioner is equipped with cooling and drying functions. Details on these functions are provided  
below; refer to these descriptions when using the air conditioner.  
Microprocessor Controlled Operation  
The interior compartment of the remote control  
unit contains several features to facilitate  
automatic operation, each logically displayed for  
easy use.  
Air Sweep Control  
This function moves a flap up and down in the  
air outlet, directing air in a sweeping motion  
around the room and providing comfort in every  
corner.  
Simple One-touch Wireless Remote Control  
The remote control unit has several features to  
facilitate automatic operation.  
Automatic Restart Function for Power Failure  
Even when power failure occurs, preset pro-  
grammed operation can be reactivated once  
power resumes.  
24-Hour ON or OFF Timer  
This timer can be set to automatically turn the  
unit on or off at any time within a 24 hour  
period.  
Anti-Mold Filter  
This unit is equipped with an anti-mold filter  
that inhibits the growth of mold and bacteria.  
1-Hour OFF Timer  
This timer can be set to automatically turn off  
the unit at any time after one hour.  
Optional Air Clean Filter  
An air filter that uses activated charcoal to  
eliminate unpleasant odors and clean the air is  
available (sold separately).  
Night Setback  
Pressing this button changes the setting of the  
room temperature thermostat, allowing you to  
set the temperature at whatever level that you  
find comfortable.  
Automatic and 3-step Fan Speed  
Auto/High/Medium/Low  
2
OI-508-02EG  
Contents  
Page  
Features.................................................................................................................. 2  
Product Information.............................................................................................. 3  
Alert Symbols........................................................................................................ 3  
Installation Location.............................................................................................. 4  
Electrical Requirements........................................................................................ 4  
Safety Instructions ................................................................................................ 4  
Names of Parts...................................................................................................... 5  
Using the Remote Control Unit ......................................................................... 10  
Operation with the Remote Control Unit.......................................................... 12  
1. Manual Operation ................................................................................. 12  
2. Adjusting the Fan Speed...................................................................... 13  
3. Night Setback Mode ............................................................................ 14  
Special Remarks ................................................................................................. 15  
Setting the Tim er................................................................................................. 16  
Setting the 1-Hour OFF Timer............................................................................ 18  
Adjusting the Airflow Direction ......................................................................... 19  
Operation without the Remote Control Unit.................................................... 20  
Care and Cleaning............................................................................................... 20  
Tips for Energy Saving ...................................................................................... 23  
Troubleshooting................................................................................................... 24  
Operating Range ................................................................................................. 24  
Product Information  
If you have problems or questions concerning your Air Conditioner, you will  
need the following information. Model and serial numbers are on the  
nameplate on the bottom of the cabinet.  
Model No.  
Serial No.  
Date of purchase  
Dealer’s address  
Phone number  
Alert Symbols  
The following symbols used in this manual, alert you to potentially  
dangerous conditions to users, service personnel or the appliance:  
This symbol refers to a hazard or unsafe  
practice which can result in severe personal  
injury or death.  
This symbol refers to a hazard or unsafe  
CAUTION  
practice which can result in personal injury  
or product or property damage.  
OI-508-03EG  
3
Installation Location  
We recommend that this air conditioner be installed properly by  
qualified installation technicians in accordance with the Installation  
Instructions provided with the unit.  
Before installation, check that the voltage of the electric supply in your  
home or office is the same as the voltage shown on the nameplate.  
Do not install this air conditioner where there are fumes or flammable  
gases, or in an extremely humid space such as a greenhouse.  
Do not install the air conditioner where excessively high heat-  
generating objects are placed.  
Avoid:  
To protect the air conditioner from heavy corrosion, avoid installing the  
outdoor unit where salty sea water can splash directly onto it or in  
sulphurous air near a spa.  
Electrical Requirements  
1. All wiring must conform to the local electrical codes. Consult your  
dealer or a qualified electrician for details.  
2. Each unit must be properly grounded with a ground (or earth) wire or  
through the supply wiring.  
3. Wiring must be done by a qualified electrician.  
Safety Instructions  
Read this Instruction Manual carefully before using this air conditioner.  
If you still have any difficulties or problems, consult your dealer for  
help.  
This air conditioner is designed to give you comfortable room  
conditions. Use this only for its intended purpose as described in this  
Instruction Manual.  
Never use or store gasoline or other flammable vapor or liquid near  
the air conditioner — it is very dangerous.  
This air conditioner has no ventilator for intaking fresh air from  
outdoors. You must open doors or windows frequently when you use  
gas or oil heating appliances in the same room, which  
consume a lot of oxygen from the air. Otherwise there is a risk of  
suffocation in an extreme case.  
CAUTION  
Do not turn the air conditioner on and off from the power mains  
switch. Use the ON/OFF operation button.  
Do not stick anything into the air outlet of the outdoor unit. This is  
dangerous because the fan is rotating at high speed.  
Do not let children play with the air conditioner.  
Do not cool the room too much if babies or invalids are present.  
4
OI-508-04EG  
Names of Parts  
INDOOR UNIT  
Air intakes  
Air outlet  
Rem ote  
control  
unit  
Drain  
hose  
Refrigerant  
tubes  
OUTDOOR UNIT  
Air outlet  
This illustration is based on the external appearance of a standard model.  
Consequently, the shape may differ from that of the air conditioner which  
you have selected.  
NOTE  
This air conditioner consists of an indoor unit and an outdoor unit.  
You can control the air conditioner with the remote control unit.  
Air Intakes  
Air from the room is drawn into these sections and passes through  
air filters which remove dust.  
Air Outlet  
Air is blown out of the air conditioner through the air outlet.  
Remote Control Unit  
Refrigerant Tubes  
The wireless remote control unit controls power on/off, operation  
mode selection, temperature, fan speed, timer setting, night  
setback and air sweeping.  
The indoor and outdoor units are connected by copper tubes  
through which refrigerant gas flows.  
Drain Hose  
Moisture in the room condenses and drains off through this hose.  
Outdoor (Condensing) Unit  
The outdoor unit contains the compressor, fan motor, heat  
exchanger coil, and other electrical components.  
OI-508-05EG  
5
Unit Display and Operation Selector  
INDOOR UNIT  
ON  
OFF  
TEST  
Operation selector  
Remote control  
IMPORTANT  
OPERATION lamp  
TIMER lamp  
receiver  
Avoid using radio equipment  
such as mobile phone near  
(within 4 ft. of) the indoor unit.  
Some radio equipment may  
cause the unit to malfunction.  
OPERATION  
TIMER  
If the trouble occurs, dis-  
connect power and restart the  
air conditioner after a few  
minutes.  
REMOTE CONTROL  
This section picks up infrared signals from the remote control unit  
(transmitter).  
receiver  
Operation selector  
ON position  
This position is for operating the air conditioner with the wireless  
remote control unit.  
Set the selector normally in this position.  
OFF position  
Switch the selector to the OFF position if you are not going to use  
the air conditioner for a few days or longer.  
The OFF position does not disconnect the power. Use the main  
power switch to turn off power completely.  
TEST position  
CAUTION  
This position is used only when servicing the air conditioner.  
Do not set the operation selector at the TEST position for normal  
operation.  
OPERATION lamp  
TIMER lamp  
This lamp lights when the system is in the continuous DRY and  
COOL mode.  
This lamp lights when the system is being controlled by the timer.  
6
OI-508-06EG  
Remote Control Unit (Display)  
ROOM TEMP” is displayed when the tem perature setting has  
not been m ade.  
TEMP” is displayed when setting tem perature.  
Displayed when m ain unit sensor is in use  
Displayed when transm itting data  
Displayed when tem perature is  
shown  
Displayed when the tem perature  
setting is at the upper or lower  
allowable lim it  
Displayed when setting tim er  
Sym bols  
(1) Operation m ode  
(4) Tim er  
24-hour clock with ON/OFF  
program Tim er .......................  
24-hour ON Tim er..................  
24-hour OFF Tim er.................  
1-hour OFF Tim er...................  
MILD DRY................................  
COOL .......................................  
ON  
OFF  
(2) Fan speed  
1HR.  
AUTO.......................................  
(5) NIGHT SETBACK....................  
HIGH ........................................  
MEDIUM..................................  
LOW.........................................  
(6) Confirm ation of  
transm ission ...........................  
(7) Flap  
Angle indication .....................  
(3) Tem perature setting  
60 — 86 °F  
Sweep indication....................  
When set to 82 °F  
tem perature indication ......  
OI-508-07EG  
7
Remote Control Unit (continued)  
Program button For details, see “Setting theTimer.  
Press this button to select the mode you want to program.  
TIMER SELECT button No display : The timer does not operate.  
: The air conditioner stops at the set time.  
: The air conditioner starts at the set time.  
: The air conditioner stops and starts, or starts and stops, at the  
set times every day.  
MODE selector button Use this button to select the DRY or COOL mode.  
(DRY)  
(COOL)  
: The air conditioner reduces the humidity in the room.  
: The air conditioner makes the room cooler.  
FLAP button Press this button either to select to set the airflow direction to one of the six  
possible positions manually, or to select the sweep function, which moves  
the flap up and down automatically.  
: The airflow direction can be set manually. (six positions)  
: The flap moves up and down automatically.  
NOTE When you press the FLAP button, the air flow direction will be changed one  
by one as follows.  
Swing  
FAN SPEED selector button  
: The air conditioner automatically decides the fan speeds.  
: High fan speed  
: Medium fan speed  
: Low fan speed  
1 HR.TIMER button  
(1-HOUR OFFTIMER)  
: When you press this button, regardless of whether the unit is  
operating or stopping, the unit operates for one hour and then  
shuts down.  
ACL button (ALL CLEAR) Puts the remote control unit into pre-operation status. Always press this  
button after replacing the batteries.  
ADDRESS switch  
Change the address switch to prevent mixing of signals from remote control  
units when two Sanyo air conditioners are installed next to each other.  
Normally, the address switch is set to A. When switching the address, the  
remote control must be changed, and the jumper cables on the indoor unit  
board must be cut. For more information, please contact the dealer where  
you made the purchase.  
Normally, the tabs on the remote control unit should not be bent.  
SENSOR button When you press this button (use a small-tipped object such as a ballpoint  
pen), the mark will appear at the display. And the room temperature is  
detected by the sensor which is built into the indoor unit and the air  
conditioner is controlled accordingly.  
NOTE If the remote control is located near a heat source, such as a space heater or  
in direct sunlight, press the SENSOR button to switch to the sensor on the  
indoor unit.  
NOTE The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals.  
If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote  
control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into  
the indoor unit and control the room temperature. In these cases, the temperature around the remote  
control unit may differ from the temperature detected at the air conditioners position.  
OI-508-9EG  
9
Using the Remote Control Unit  
How to Install Batteries  
1. Slide the cover in the direction indicated by  
the arrow and remove it.  
2. Install two AAA alkaline batteries. Make sure  
the batteries point in the direction marked in  
the battery compartment.  
3. Use a thin object such as the tip of a pen to  
press the ACL button.  
ACL button  
The batteries last about six months, depending on how much you use  
NOTE  
the remote control unit. Replace the batteries when the remote control  
unit’s display fails to indicate, or when the remote control cannot be  
used to change the air conditioner’s settings.  
Use two fresh leak-proof type-AAA alkaline batteries.  
In replacing batteries, follow the instructions as mentioned in the  
sub-section ‘‘How to Install Batteries’’.  
If you do not use the remote control unit more than 1 month, take out  
the batteries.  
How to Use the Remote  
Control Unit  
When using the remote control unit, always point the unit’s transmitter  
head directly at the air conditioner’s receiver.  
Air conditioner  
(Indoor unit)  
Receiver  
(Transmitter head)  
Remote control  
unit  
Remote Control Unit  
Installation Position  
The remote control unit may be operated either from a non-fixed position  
or from a wall-mounted position. To ensure that the air conditioner operates  
correctly, DO NOT install the remote control unit in the following places:  
DO NOT  
In direct sunlight  
Behind a curtain or other places where it is covered  
More than 26 feet (8 m) away from the air conditioner  
In the path of the air conditioner’s airstream  
Where it may become extremely hot or cold  
Where it may be subject to electrical or magnetic noise  
Where there is an obstacle between the remote control unit and air  
conditioner (since a check signal is sent from the remote control unit  
every 5 minutes)  
10  
OI-508-10EG  
Using the Remote Control Unit (continued)  
Mounting the Remote  
Control Unit  
Truss-head  
tapping screws  
5/32 x 5/8 “ (4 x 16 mm)  
(supplied)  
Press  
Remote  
control  
unit holder  
Hook  
When attaching to wall 1) Confirm the indoor unit beeps when the ON/OFF button is pressed at the  
wall location where the remote control unit is to be attached, then attach  
the holder to the wall.  
2) When taking out the remote control unit, pull it from the holder.  
When using the remote  
control unit  
Point the transmitter on the remote control unit at the sensor on the  
indoor unit when operating the remote control unit and the air conditioner.  
Do not place objects which may block the transmitted signals between  
the receiver and the remote control unit.  
Truss-head  
tapping screws  
5/32 x 5/8 “ (4 x 16 mm)  
(supplied)  
Holder  
Remote  
control  
unit holder  
Securing the remote 1) Attach the holder to the wall with one screw in the upper hole only.  
control unit to prevent theft  
2) Remove the cover from the remote control unit, and then remove the  
batteries. Next, place the remote control unit in the holder.  
3) Secure both the remote control unit and the holder to the wall with another  
screw through the lower hole.  
4) Put the batteries back in the remote control unit, and then replace the  
cover.  
OI-508-11EG  
11  
Operation with the Remote  
Control Unit  
1. Manual Operation  
STEP 2  
STEP 3  
STEP 4  
STEP 1  
STEP 5  
Check that the circuit breaker on the power panel is turned on and that the  
operation selector of the indoor unit is in the ON position.  
NOTE  
Press the setting buttons as described below and change the settings as  
desired.  
STEP 1  
Press the MODE selector button and select the desired  
m ode.  
For drying operation  
For cooling operation  
To start the air conditioner, press the ON/OFF  
operation button.  
STEP 2  
STEP 3  
Press the tem perature setting buttons to change the  
tem perature setting to the desired tem perature.  
Adjustable tem perature range:  
86 °F m ax.  
60 °F m in.  
The tem perature setting changes by two degrees each  
tim e the button is pressed. (The air conditioner  
rem em bers the new tem perature setting even when it is  
turned off.)  
NOTE  
Set the FAN SPEED selector button to the setting you want.  
STEP 4  
NOTE  
If the fan speed is set to  
(Autom atic), the fan speed  
switches autom atically, according to the difference  
between the actual room tem perature and the tem perature  
setting.  
STEP 5  
Press the FLAP button and set the airflow direction as  
desired.  
(Refer to ˝Adjusting the Airflow Direction˝ on page 19.)  
To stop the air conditioner, press the ON/OFF operation button again.  
12  
OI-508-12EG  
Operation with the Remote Control Unit (continued)  
This appliance has a built-in three m inutes tim e delay circuit to ensure  
NOTE  
reliable operation. When the operation button is pressed, the  
com pressor will start running within three m inutes. In the event of  
power failure, the unit will stop. When the power is restored, the unit  
will restart autom atically after five m inutes.  
2. Adjusting the  
Fan Speed  
A. Autom atic  
Sim ply set the FAN SPEED selector button to the  
position.  
A m icrocom puter in the air conditioner autom atically controls the fan speed  
when the m ode is selected. When the air conditioner starts operating,  
the difference between the room tem perature and the set tem perature is  
detected by the m icrocom puter which then autom atically switches the fan  
speed to the m ost suitable level.  
Cooling and DRY m ode:  
When difference betw een  
room tem perature and set FAN SPEED  
tem perature is  
4 °F and over  
High  
Between 4 °F and 2 °F  
Below 2 °F  
Medium  
Low  
The above m entioned data m ake reference to the conditioner operating  
when the sensor on the rem ote control unit is ON. (Refer to tem perature  
sensor selector). If the sensor on the indoor unit is being used then  
actual operation will slightly differ from that described in the above  
NOTE  
tables. (  
Sign shown on the rem ote control unit display.)  
B. Manual  
If you want to adjust fan speed m anually during operation, just set the FAN  
SPEED selector button as desired. [ , or  
,
]
OI-508-13EG  
13  
Operation with the Remote Control Unit (continued)  
3. Night Setback Mode  
The Night Setback Mode is used for saving energy.  
Press the NIGHT SETBACK button while the air conditioner is operating.  
The  
m ark appears in the display.  
To cancel the night setback function, press the NIGHT SETBACK button  
again.  
In Cooling and DRY  
Mode:  
When the night setback m ode is selected, the air conditioner  
autom atically raises the tem perature setting 2 °F when 30 m inutes  
have passed after the selection was m ade, and then another 2 °F after  
another 30 m inutes have passed, regardless of the indoor tem perature  
when night setback was selected. This enables you to save energy  
without sacrificing com fort. This function is convenient when gentle  
cooling is needed.  
(
and  
)
2 °F  
Setting  
tem perature  
2 °F  
30 m in.  
30 m in.  
NIGHT SETBACK  
button  
Press the  
Tim e  
14  
OI-508-14EG  
Special Remarks  
‘‘DRY’’ ( ) Operation  
How it works?  
Once the room temperature reaches the level that was set, the unit  
repeats the cycle of turning on and off automatically.  
During DRY operation, the fan speed is automatically set to LOW or  
VERY LOW; the fan speed then switches back and forth between LOW  
(for 20 seconds) and VERY LOW (for 10 seconds).  
‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or  
less.  
In the event of power failure, the unit will stop. When the power is  
turned on again, the unit restarts within five minutes.  
Power failure  
during operation  
Clicking Sound  
Clicking sound is  
heard from the air  
conditioner  
In cooling and drying operation, any plastic parts may expand or shrink  
due to a sudden temperature change. In this event, a clicking sound  
may occur. This is normal, and the sound will soon disappear.  
The remote control unit sends the setting condition to the air  
conditioner regularly at five minute intervals.  
Remote Control Unit  
OI-508-15EG  
15  
Setting theTimer  
3
4
2
1
(Example)To set to 9:10 pm.  
1. How to set the  
present time  
Operation  
Indication  
1. Press the Program button (  
three times.  
)
The time indication alone blinks.  
2. Press the HH button until PM 9 is  
displayed.  
The display will automatically  
stop blinking except for the “:”  
symbol after 10 sec.  
Press the MM button until 10 is  
displayed.  
(Example)To stop the air conditioner at 11:30 pm.  
2. How to set the OFF time  
The timer  
and present OFF time is shown.  
indication blinks  
1. Press the Program button (  
once.  
)
2. Press the HH button until PM 11 is  
displayed.  
The display will change  
automatically back to show the  
present time after 10 sec.  
Press the MM button until 30 is  
displayed.  
3. Press the ON/OFF button to start the The present time is displayed.  
air conditioner.  
4. Press theTIMER SELECT button to  
set OFF time.  
The present time and  
displayed.  
are  
16  
OI-508-16EG  
Setting theTimer (continued)  
(Example)To start operation at 7:10 am.  
3. How to set the ON time  
Operation  
Indication  
1. Press the Program button (  
twice.  
)
The timer  
and present ON time is shown.  
indication blinks  
2. Press the HH button until AM 7 is The display will change  
displayed.  
automatically back to show the  
present time after 10 sec.  
Press the MM button until 10 is  
displayed.  
3. Press the ON/OFF button to start the The present time is displayed.  
air conditioner.  
The present time and  
displayed.  
are  
4. Press theTIMER SELECT button to  
set ON time.  
4. How to set a program  
for daily ON/OFF  
operation  
(Example) To start operation at 7:10 am. and stop the air conditioner at  
11:30 pm.  
7:10 am  
ON  
11:30 pm  
OFF  
Present  
time  
1. Set the timer ON/OFF times as  
OFF  
time  
shown in 2-1, 2 and 3-1, 2.  
2. Press the ON/OFF button to start the  
air conditioner.  
3. Press theTIMER SELECT button to  
set the ON/OFF combination timer.  
The present time PM 9:10 and  
are displayed.  
ON  
time  
NOTE  
When the Daily ON/OFF program is set to start the air conditioner  
before the ON time setting, the  
indications appear on the  
display.  
On the other hand, when the Daily ON/OFF program is set to start the  
air conditioner after the ON time setting, the indications  
appear on the display.Thus, these indications show the timer program  
which will operate next.  
Programed  
daily  
ON/OFF  
NOTE  
You can check the timer ON/OFF times after you have set them by  
pressing the PROGRAM button.  
OI-508-17EG  
17  
Setting the 1-Hour OFFTimer  
1. 1-Hour OFFTimer  
This function causes the unit to operate for one hour and then stop, regardless  
of whether the unit is on or off when this button is pressed.  
The  
indicator in the display indicates that this function is operating.  
Setting procedure:  
Regardless of whether the unit is operating or stopped, press the 1 HR.TIMER  
button.  
appears in the display.  
Cancellation procedure:  
Press the ON/OFF operation button to turn the unit off, wait for the unit to stop  
operating, and then press the ON/OFF operation button again.The 1-HourTimer  
function is now cancelled and the unit operates normally.  
NOTE  
If, while the 1-HourTimer function is operating, the 1 HR.TIMER button is  
pressed once to cancel the function and then again, the unit continues to  
operate for one hour from that point in time and then stops.  
The 1-Hour OFFTimer setting is given priority over the daily program  
setting.  
2. OperationTogether  
with the ProgramTimer  
It is not possible to use the OFFTimer and 1-Hour OFFTimer together.  
Whichever function is set last takes precedence.  
If the 1 HR.TIMER button is pressed while theTIMER OFF function operates,  
OFFTimer is cancelled and the unit will stop operating one hour later  
18  
OI-508-18EG  
Adjusting the Airflow Direction  
1. Horizontal  
The horizontal airflow can be adjusted by moving the vertical vanes with your  
hands to the left or right.  
CAUTION  
2.Vertical  
When the humidity is high, the vertical vanes should be in the front  
position during the cooling or drying operation. If the vertical vanes  
are positioned all the way to the right or left, condensation may begin  
to form around the air vent and drip down.  
The vertical airflow can be adjusted by moving the flap with the remote  
control unit. Do not move the flap with your hands. Confirm that the remote  
control unit has been turned on. Use the FLAP button to set either the  
sweep function or one of the six airflow direction settings.  
(The maximum capacity is obtained at the position at 4.)  
COOL  
and  
DRY  
SWEEP  
(Recommended  
operating  
range)  
A. Sweep function  
B. Setting the airflow manually  
The flap starts moving up and down to  
deliver air over the sweep range.  
Referring to the above illustration, use  
the FLAP button to set the airflow  
direction within the range used during  
the cooling or drying operation.  
NOTE  
The flap automatically closes when the unit is off.  
CAUTION  
Use the FLAP button on the remote control to adjust the position of the flap.  
If you move the flap by hand, the flap position according to the remote control  
and the actual flap position may no longer match. If this should happen, shut  
off the unit, wait for the flap to close, and then turn on the unit again; the flap  
position will now be normal again.  
Do not have the flap pointed down during cooling operation.  
Condensation may begin to form around the air vent and drip down.  
OI-508-19EG  
19  
Operation without the Remote  
Control Unit  
INDOOR UNIT  
If you have lost the remote control unit or it has trouble, follow the steps below.  
1. When the air conditioner is not running  
If you want to turn on the air conditioner, switch the operation selector to the  
OFF position, and then to the ON position.  
Operation  
selector  
ON  
OFF  
TEST  
NOTE The set temperature and fan speed are automatically set at the last  
selection before stopping.  
2. When the air conditioner is running  
If you want to turn off the air conditioner, switch the operation selector to the  
OFF position.  
Care and Cleaning  
1. For safety, be sure to turn the air conditioner off and also to disconnect  
the power before cleaning.  
WARNING  
2. Do not pour water on the indoor unit to clean it.This will damage the  
internal components and cause an electric shock hazard.  
Casing and Grille  
(Indoor Unit)  
Clean the casing and grille of the indoor unit with a vacuum cleaner brush,  
or wipe them with a clean, soft cloth.  
If these parts are stained, use a clean cloth moistened with a mild liquid  
detergent. When cleaning the grille, be careful not to force the vanes out of  
place.  
1. Never use solvents, or harsh chemicals when cleaning the indoor unit.  
Do not wipe the plastic casing using very hot water.  
CAUTION  
2. Some metal edges and the fins are sharp and may cause injury if handled  
improperly; be especially careful when you clean these parts.  
3. The internal coil and other components of the outdoor unit must be  
cleaned every year. Consult your dealer or service center.  
20  
OI-508-20EG  
Care and Cleaning (continued)  
Anti-mold filter  
The anti-mold filter behind the air intake grille should be checked and cleaned  
at least once every two weeks.  
1. Grasp both ends of the  
How to remove the  
anti-mold filter  
Air intake grille  
air intake grille and  
pull it out and up.  
2. Push the anti-mold  
filter up slightly, and  
then pull it down.  
Anti-mold filter  
Cleaning  
Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter,  
wash the filter in lukewarm, soapy water, rinse it in clean water and dry it.  
How to replace the  
anti-mold filter  
1. With the ˝FRONT˝ mark facing  
you, slide the anti-mold filter  
up into the unit and then  
lower the handle into the  
groove on the unit.  
Air intake grille  
2. After installing the anti-mold  
filter, press the locations  
marked by the arrows (  
and close the air intake grille.  
)
Anti-mold  
filter  
Insert into the groove on the unit.  
OI-508-21EG  
21  
Care and Cleaning (continued)  
Air cleaning filter  
(not provided)  
The air cleaning filter removes dust and dirt from the air, and reduces odors  
and smoke from tobacco.  
The air clean filter is not provided with the air conditioner and must be purchased  
separately.  
NOTE  
Ask for the STK-F4B model when purchasing.  
WARNING  
The air cleaning filter cannot remove harmful gases or vapors nor ventilate air  
in the room.You must open doors or windows frequently when you use gas or  
oil heating appliances. Otherwise there is a risk of suffocation in extreme cases.  
The air cleaning filter needs to be  
installed behind the anti-mold filter.  
How to install the air  
cleaning filter  
Air clean filter  
(STK-F4B)  
1. Remove the anti-mold filter.  
2. To mount the STK-F4B, set the  
air clean filter (sold separately)  
at the mounting position with  
the black side facing the rear.  
3. Reinstall the anti-mold filter,  
and close the suction grill.  
NOTE  
In general, the filter should be  
replaced once every three  
months.  
Dirty air clean filters cannot be  
washed and reused. Purchase a  
replacement filter at your local  
dealer.  
Cleaning the main unit and  
remote control unit  
Wipe clean using a soft, dry cloth.  
To remove stubborn dirt, moisten a cloth in warm water no hotter than  
104°F, wring thoroughly, and then wipe.  
The air intake grille can be removed in order to wash it with water.  
22  
OI-508-22EG  
Care and Cleaning (continued)  
Removing and remounting  
the air intake grille  
Air intake grille  
Arm  
With the air intake grille open all  
the way, grip both arms with  
your hands and pull toward you  
to remove.  
To remount, hold the air intake  
grille roughly horizontal and  
push it in until the arm shafts fit  
into the indentations in the main  
unit, then fit the grille into place.  
CAUTION  
When using a footstool or the like, be careful not to let it tip over.  
Washing the grille with  
water  
Clean the grille gently using a soft sponge, or the like.Then wipe away any  
remaining moisture.  
Neutral detergent may be used to remove stubborn dirt.Then rinse thoroughly  
with water and wipe away any remaining moisture.  
Tips for Energy Saving  
Do not  
Block the air intake and outlet of the unit. If they are obstructed, the  
unit will not work well, and may be damaged.  
Let direct sunlight into the room. Use sunshades, blinds or curtains. If  
the walls and ceiling of the room are warmed by the sun, it will take  
longer to cool the room.  
Do  
Always try to keep the air filter clean. (Refer to “Care and Cleaning.)  
A clogged filter will impair the performance of the unit.  
To prevent conditioned air from escaping, keep windows, doors and any  
other openings closed.  
OI-508-23EG  
23  
Troubleshooting  
If your air conditioner does not work properly, first check the following points before requesting service. If it still  
does not work properly, contact your dealer or service center.  
Trouble  
Possible Cause  
1. Power failure.  
2. Leakage circuit breaker tripped.  
3. Line voltage is too low.  
4. Operation button is OFF.  
5. Batteries in remote control unit  
have run down.  
Remedy  
1. Restore power.  
2. Contact service center.  
3. Consult your electrician or dealer.  
4. Press the button again.  
5. Replace batteries.  
Air conditioner does not  
run at all.  
Trouble in wiring system.  
Contact service center.  
OPERATION lamp flashes  
and air conditioner does  
not operate.  
Obstruction in front of condenser coil. Remove obstruction.  
Compressor runs but soon  
stops.  
Poor cooling performance.  
1. Dirty or clogged air filter.  
2. Heat source or many people in  
room.  
1. Clean air filter to improve airflow.  
2. Eliminate heat source if possible.  
3. Doors and/or windows are open.  
4. Obstacle near air intake or air  
discharge port.  
3. Shut them to keep the heat out.  
4. Remove it to ensure good airflow.  
5. Thermostat is set too high for  
cooling.  
5. Set the temperature lower.  
Clicking sound is heard  
from the air conditioner.  
In cooling and drying operation, any  
plastic parts may expand or shrink  
due to a sudden temperature change.  
In this event, a clicking sound may  
occur.  
This is normal, and the sound will  
soon disappear.  
OPERATION lamp lights  
but outdoor unit will not  
run.  
1. The use of portable telephones  
near the air conditioner may cause  
disturbance to its normal  
operation.  
1. Turn off the power then restart the  
air conditioner after 1 minute.  
2. Consult your dealer.  
Operating Range  
The air conditioner is operable within the temperature ranges as listed below:  
Temperature  
Maximum  
Indoor Air IntakeTemperature  
Outdoor Air IntakeTemperature  
95 °F DB/71 °F WB  
67 °F DB/57 °F WB  
115 °F DB  
67 °F DB  
Cooling Model  
Minimum  
Maximum  
Low Ambient  
Temperature  
Model  
95 °F DB/71 °F WB  
115 °F DB  
Minimum  
67 °F DB/57 °F WB  
0 °F DB  
In Canada  
SANYO FISHER COMPANY  
A DIVISION OF SANYO NORTH AMERICA CORPORATION  
21605 Plummer Street  
SANYO Canada Inc.  
300 Applewood Crescent,  
Concord, Ontario,  
L4K 5C7, Canada  
OI-508-24EG  
Chatsworth, CA 91311 U.S.A.  
24  

Schumacher Sf 2001 User Manual
Samsung Aw1801b User Manual
Manual De Control Universal User Manual
LG 22MT45A User Manual
KENWOOD KM280 02 User Manual
KENWOOD KDC MP258U User Manual
CRAFTSMAN 536.886260 User Manual
Bodum Fondue User Manual
BLACK DECKER NPT318 User Manual
BLACK DECKER DP240S User Manual