Nlynx Newport 9000 User Manual

Owner’s Manual  
Please read and fully understand this manual before  
operating your NEWPORT 9000.  
Advanced PureAirTM Newport 9000 Owner’s Manual  
CONTROLS & AIR FLOW VENTS  
Front Face Plate  
Air Outlet  
Dust Sensor  
Air Inlets  
Air Inlets  
Front Panel Release Tabs  
Bottom Stand  
Soft Touch Control Panel  
Remote Control  
Odor Sensor  
ON/OFF  
AUTO  
FLOW  
ION UV  
TIMER  
2
Advanced PureAirTM Newport 9000 Owner’s Manual  
MAJOR COMPONENTS  
Back View  
Exploded Parts View  
3
Advanced PureAirTM Newport 9000 Owner’s Manual  
BEFORE USE  
Pre-Installation Air Ventilation  
Open Windows for Air Ventilation  
Before plugging in the unit,  
please open the windows in  
the area where you will be using  
the unit. Ventilate the area for 2-3  
hours if possible. Once the area  
has been ventilated, close the  
windows and plug in the unit.  
After plugging in, the unit sensor will sample the air and retain a memory of the existing indoor  
air condition. (The existing indoor air condition will be input as "CleanAir").  
Once started, the odor indicator will blink as it memorizes the existing fresh air condition.  
After two minutes, the indicator will stop blinking to indicate the end of memorization.  
Please Note: Whenever the unit is unplugged, all memorized content will be erased.  
If the unit is turned on two minutes after plugging it in, the odor sensor indicator will not blink.  
When smoke, cosmetics, or any spray that contains alcohol is present, please ventilate and  
freshen the air before closing windows.  
Sometimes the sensor is not as sensitive when first purchased or after being unplugged  
for over a week. Its sensitivity will begin to increase after one to two days of operation.  
4
Advanced PureAirTM Newport 9000 Owner’s Manual  
EXPLANATION OF INDICATORS  
Negative Ion Indicator  
During the process when negative ions are generated, the blue indicator on the Soft Touch Control Panel  
will gradually change from bright to dim and from dim back to bright every 5seconds.  
Odor Indicator  
The odor indicator on the Soft Touch Control Panel will glow whenever the odor sensor detects odor  
(such as indoor smoke).  
Dust and Irritant Indicator  
The dust-and-irritant indicator on the Soft Touch Control Panel will glow whenever dust or other irritants  
are detected.  
Air Quality Surveillance  
Whenever odor, dust, or irritants are detected, the air quality surveillance function will indicate the level  
of pollution on the Soft Touch Control Panel. When pollution is severe, all the LED’s will glow.  
LED Examples for Air Quality Surveillance  
No pollution detected  
Some pollution detected  
Severe pollution detected  
5
Advanced PureAirTM Newport 9000 Owner’s Manual  
OPERATING INSTRUCTIONS  
Locate the Unit  
Place the Newport 9000 against a wall, near an electric outlet with 12-15 inches clearance on the front  
and sides. It is best to place the unit where it will be out of any children's play area.  
How to Start  
Plug the unit into a standard 120V/60Hz outlet. Press the POWER ON/OFF button. The device starts  
operating automatically and the negative-ion UV indicator will automatically turn on. Press POWER ON/OFF  
again and the device will turn off.  
Fan Modes  
This Newport 9000 has five different fan modes to choose from. Please choose a proper  
level of circulation according to indoor air quality and room size. As you press FAN,  
the fan mode will change according to the number of times you press the button.  
The LED will show the following sequence of modes:  
QUIET  
LOW  
MED  
HI  
AUTO  
Automatic Operation  
Keep pressing the FAN button until the device runs under automatic operation  
(the LED will show AUTO).  
Under automatic operation, the device automatically switches to the proper  
running modes (MED or LOW) according to the level of odor, dust, or irritants  
in the air as detected by the sensor. As the air is purified, the device will auto-  
matically switch back to LOW or QUIET modes.  
Timed ON/OFF  
Press AUTOTIMER button to set operation timing.  
Under the AUTOTIMER function, the operation timing will be set according to  
the number of times you press the AUTOTIMER button. The LED will show the  
following sequence of timing:  
1 HOUR  
2 HOUR  
8 HOUR  
6
Advanced PureAirTM Newport 9000 Owner’s Manual  
CLEANING AND MAINTENANCE  
Before starting any cleaning or maintenance, always turn-off and unplug the unit.  
Regular cleaning and maintenance is recommended every 2-3 months.  
Disassembling the Newport 9000  
After unplugging, carefully lay the unit down face-up. Disassemble the unit in sequence of 1 to 5  
as shown below. (Put the unit back together in the reverse 5 to 1 sequence.)  
3. Remove the Washable Plasma Dust Filter  
1. Remove the Front Face Plate  
4. Remove the HEPA/Activated Charcoal Filter  
2. Remove the Washable Pre-Filter  
.
.
.
5. Remove the TiO2 Filter  
Hold the clips of both sides to help pulling  
out the filter.  
7
Advanced PureAirTM Newport 9000 Owner’s Manual  
(
CLEANING AND MAINTENANCE CONT.  
)
Regular Cleaning and Maintenance  
Unit Body  
Front Face Plate  
For  
Instructions  
regarding the  
disassembly of the  
Can be cleaned with flowing water  
face plate and  
filters refer to  
page 7.  
Please use a soft cloth to clean and avoid scraping  
off the paint on the cover  
Take down UV lamp before cleaning  
Use wring dry cloth to rub and clean.  
Avoid cleaning with hot water or rubbing too hard  
or paint damage or deformation could occur.  
8
Advanced PureAirTM Newport 9000 Owner’s Manual  
(
CLEANING AND MAINTENANCE CONT.  
)
Cleaning and Maintenance of the Washable Plasma Dust Filter  
The Washable Plasma Dust Filter needs cleaning when:  
1) The cleaning indicator is glowing or blinking.  
2) The dust collector is making electrical discharge sounds.  
3) The device has been used frequently in an area with lower  
air quality condition.  
Cleaning Instructions  
1. Remove the Front Face Plate.  
Washable Pre-Filter  
Washable Plasma Dust Filter  
2. Remove the Washable Pre-Filter.  
Please refer to  
page 7 for detailed  
instructions on the  
removal of the Front Face  
Plate, Washable Pre-Filer  
and the Washable  
Plasma Dust  
Filter.  
3. Remove the Washable Plasma Dust Filter  
Note: Please wear protective gloves to avoid  
cutting or scratching your hands.  
9
Advanced PureAirTM Newport 9000 Owner’s Manual  
(
CLEANING AND MAINTENANCE CONT.  
)
The Cleaning and Maintenance of the Washable Plasma Dust Filter (Cont.)  
4. Clean the Plasma Dust Filter  
Use mild detergent or plain water only.  
Use a soft scouring pad or toothbrush to  
clean the dust collector.  
Use warm water (below 40° C) only!  
5. If dust and dirt does not wash away easily, pre-soak with diluted  
detergent and then use a toothbrush to scrub.  
Please take care not to damage any wiring while cleaning the dust collector  
If any electrical discharge wire is broken, the device will lose part or  
all of its dust collecting capability.  
Any broken wire should be thrown away instead of being left inside the unit.  
Otherwise, a dangerous short-circuit or high-voltage sparks may occur.  
Please contact [email protected] for additional electrical discharge wire.  
Please do not clean using acidic or alkaline detergent that can create rust on the surface of device.  
Plastic Wrap  
6. Thoroughly dry all washed parts.  
After cleaning, please completely dry the unit before use.  
Operating a wet unit may cause electrical shock or malfunction.  
If the front cover of the plasma dust collector is not properly installed,  
the unit will not function.  
Please make sure the plastic wrap for the electrical discharge wire  
is located in its proper position.  
10  
Advanced PureAirTM Newport 9000 Owner’s Manual  
(
CLEANING AND MAINTENANCE CONT.  
)
Replacing  
Filters  
Please change  
filter when  
the REPLACE  
FILTER  
indicator is  
glowing.  
Note: Please ref  
er to page 7 f  
or instructions on  
filter installation and remo  
val.  
Replacing  
UV Lamp  
The life span  
of UV lamp  
is about 5,000  
hours. Replace  
UV lamp when  
it is damaged  
or when no  
blue light is  
observed.  
Remove the  
the UV lamp  
Front Face  
(refer to page  
Plate, Washable  
7 on how to  
dissemble).  
Pre-Filter, W  
ashable Plasma  
Dust Filter,  
and HEPA/Charcoal  
filter before  
replacing  
Softly twist  
the UV lamp,  
remove the  
lamp from its  
position, and  
insert a lamp  
tube of the  
same model.  
Resetting  
the CLEAN  
METAL  
GRID and  
REPLACE  
FILTER  
Indicators  
After cleaning  
Otherwise the  
The unit must  
and replacing  
two indicators  
filters, reset  
the CLEAN  
METAL GRID  
and REPLACE  
FILTER indicators.  
will remain  
on after servicing  
the unit.  
be plugged  
but turned of  
f to reset the  
CLEAN MET  
AL GRID and  
shaped object  
REPLACE  
FILTER indicators.  
The RESET  
Please use  
button is inside  
the unit (cannot  
be reached  
with finger).  
a toothpick,  
straightened  
paper clip or  
other similar  
to push the  
RESET button.  
How to Reset:  
1. CLEAN  
METAL GRID  
Indicator  
When the unit  
is plugged in,  
but turned of  
f, the resetting  
process for  
the CLEAN  
METAL GRID  
indicator is  
done by  
pushing both  
same time.  
the RESET  
and the TIMER  
buttons at the  
2. REPLACE  
FILTER  
Indicator  
When the unit  
is plugged in,  
but turned of  
f, the resetting  
process for  
the REPLACE  
FILTER indicator  
is done by  
Pushing both  
the RESET  
and the FLOW  
buttons  
at the same  
time.  
11  
Advanced PureAirTM Newport 9000 Owner’s Manual  
FREQUENTLY ASKED QUESTIONS  
Air Quality Surveillance  
Why is there is only one LED glowing all the time with the air quality surveillance function?  
Indoor air has been clean the whole time.  
For testing purpose, dust either caused by a cigarette or a dusty cloth can be released near the irritant sensor.  
If the level of pollution goes up, then the unit should be operating properly.  
The irritant sensor could be too far away from any irritant for it to detect. Please move the unit closer to your  
major sources of pollution  
Why does the air quality surveillance indicator always have two LED glowing?  
Possibly because the room is not really a closed environment and pollution keeps coming in from the outside.  
Or, because there has been pollution created indoors (e.g. smoking/pet boxes etc.) the whole time. It will  
take some time for the Newport 9000 to achieve a clean environment with only one indicator LED on.  
Why does the air quality surveillance function keep switching back and forth frequently?  
Sometimes the Irritant Sensor is affected by cell phone or other wireless equipment. When using cell phone  
or other wireless equipment, please stay away from the unit.  
Dust and Irritant Sensor  
Why does the Dust and Irritant Sensor keep blinking?  
In some locations the top of the sensor will accumulate more dust than in others Locations, This will decrease  
the efficiency of the sensor. (Please refer to page 8 for the cleaning of the sensor.)  
Odor Sensor  
Why doesn't the Odor Sensor work?  
In the initial set-up of the unit the Odor Sensor did not get properly trained. Please retrain the sensor memory.  
(Please refer to page 4 on details under Before Use).  
When first purchased or when the unit has been unplugged for more than a week, the sensor will not be as  
sensitive. After 1 to 2days of operation, the sensor will regain its sensitivity.  
12  
Advanced PureAirTM Newport 9000 Owner’s Manual  
(
FREQUENTLY ASKED QUESTIONS CONT.  
)
Filter  
Why is it so hard for the filter to get rid of dust and odors?  
Have the front and back of the HEPA/Charcoal filter been mistakenly reversed?  
The HEPA/Charcoal filter has been saturated with a serious amount of dust. (Usually dark grey in color).  
Please replace filter.  
Plasma Dust Collector  
Why is it so difficult to eliminate dust and odor?  
If the electrical discharge wires or the plasma dust collector gets too dirty. Please refer to page 10  
on how to clean and maintain.  
If an electrical discharge wire been disconnected or broken? Contact [email protected] for  
additional information and parts.  
Cannot Turn On the Unit  
Why is the unit not working even after turning it on?  
Has the plug been loosened or disconnected from the socket? Please check that the plug is properly  
plugged in to an outlet.  
Has the unit been properly reassembled after being cleaned? Please confirm. The unit will not operate if  
the Washable Plasma Dust Filter or the Front Face Plate have not properly installed.  
APPLICABLE AREAS  
The unit is designed for any indoor room or living space up to 80 square meters or over 800 square feet.  
It can be used in living or family rooms, bedrooms, offices, studios, waiting rooms, hotels, hospitals, etc.  
If the unit is to be used in a smaller room, you may prefer to have the power setting on medium or low.  
13  
Advanced PureAirTM Newport 9000 Owner’s Manual  
TECHNICAL SPECIFICATIONS  
Real Spirit Style No.: Newport 9000  
Rated Voltage: AC 120V/60Hz  
Dust Removal Rate: 1 micron 99.97% • 0.3 micron 80%  
Noise Level (dB): Quiet 20 • Low 35 • Med 45 • High 52  
Air Volume (High): 3 m3/min. • 106 ft3/min.  
Dimensions: 13.5" x 10" x 25.6” • 343 x 255 x 610 mm  
Weight: 15.1 lbs • 6850 g  
Power Consumption: 80W  
Ion Output: ˃ 2 x 106/cm3  
Activated Oxygen Output: ˂ 0.05 ppm  
UV Spectrum: ˃ 20μ w/cm2 at 10 cm distance.  
Applicable Area: 80 m2 • 861 ft2  
PRODUCT SERVICING  
In case of any malfunction, contact your retailer or email us at [email protected]..  
PRODUCT WARRANTY  
Advanced PureAir warrants the Newport 9000 air purifier to be free from manufacturing and  
material defects (excluding filters, lights, and batteries) for a period of one year from the  
original date of purchase.  
This warranty is valid only to the original owner with proof of purchase.  
Product abuse, misuse, modification, alteration, or opening of the unit housing, other than as  
required for filter replacement or routine maintenance and cleaning, will void the warranty.  
14  
Produced and distributed exclusively by:  
Real Spirit USA, Inc. • 9447 De Soto Ave • Chatsworth, CA 91311  
Customer Service Phone 888.698.2080, ext. 210  
© Copyright Real Spirit USA, Inc. 2008. All Rights Reserved  
Manufactured in China  

Siemens Sed2 Vfd Electronic Bypass Option 125 3208 User Manual
Schumacher ManualCargador De Batera ManualSe 2254 User Manual
Schumacher Elite Se 1555a User Manual
Mitsubishi Electronics Msz Ga22va User Manual
Mitel Answering Machine 5340e User Manual
Lg Gas Dryer Installation User Manual
G.SKILL RIPJAWS KM780 RGB User Manual
DELL STUDIO 1435 User Manual
CRAFTSMAN 315.218290 User Manual
BLACK DECKER FIRESTORM PS140 User Manual