Navman Fuel 2100 User Manual

FUEL 2100  
Installation and  
Operation Manual  
English .............3  
Français ......... 11  
Español ..........19  
Deutsch .......... 27  
Nederlands .... 35  
Svenska ......... 43  
Suomi .............51  
NAVMAN  
Contents  
1 Operation ......................................................................................................... 4  
Fuel Flow ........................................................................................................................... 4  
Other Fuel Functions ......................................................................................................... 4  
Changing the fuel remaining value ..................................................................................... 4  
Setting the low fuel alarm ................................................................................................... 5  
Alarm activation ................................................................................................................. 5  
Resetting the TRIP LOG or the TOTAL LOG ..................................................................... 5  
2 Instrument Setup ............................................................................................. 6  
Selecting units of measure................................................................................................. 6  
Calibration ......................................................................................................................... 6  
3 Installation ....................................................................................................... 7  
Location ............................................................................................................................. 7  
Mounting ........................................................................................................................... 7  
Wiring Connection ............................................................................................................. 8  
Installation of the fuel flow transducer ................................................................................ 8  
Appendix A - Specifications .............................................................................. 9  
Appendix B - Troubleshooting Chart .............................................................. 10  
Appendix C - How to contact us ..................................................................... 59  
Important  
It is the owner’s sole responsibility to install and use the instrument and transducer/s in a manner that will  
not cause accidents, personal injury or property damage. The user of this product is solely responsible for  
observing safe boating practices.  
NAVMAN NZ LIMITED DISCLAIMSALL LIABILITY FORANY USE OF THIS PRODUCT INAWAYTHAT  
MAY CAUSE ACCIDENTS, DAMAGE OR THAT MAY VIOLATE THE LAW.  
This manual represents the FUEL 2100 as at the time of printing. Navman NZ Limited reserves the right  
to make changes to specifications without notice.  
Governing Language: This statement, any instruction manuals, user guides and other information relating  
to the product (Documentation) may be translated to, or has been translated from, another language  
(Translation). In the event of any conflict between any Translation of the Documentation, the English  
language version of the Documentation will be the official version of the Documentation.  
Copyright © 2002 Navman NZ Limited, New Zealand.All rights reserved. NAVMAN is a registered trademark  
of Navman NZ Limited.  
3
NAVMAN  
FUEL 2100 Installation and Operation Manual  
1 Operation  
Fuel Flow  
Changing the fuel remaining value  
Press the  
rate.  
key to display the current fuel flow  
To change the value of fuel remaining in the tank,  
press the  
key until the display indicates  
for  
two seconds and then displays the current value.  
FLOW  
^
TOTAL  
V
FLOW  
^
TOTAL  
V
#
ꢀꢁꢂꢀ  
ꢀꢁꢂ  
ꢃꢄꢅꢆ  
Other Fuel Functions  
Press the  
key to cycle through the possible  
key is pressed the display  
functions. Each time the  
will show an identifier for 2 seconds before the value  
is displayed.  
Press and hold both keys for three seconds and the  
displayed value will begin to flash.  
Press and hold for 3 seconds  
Fuel used on trip  
TOTAL  
V
260  
keys to change the value. Press  
tOt  
Fuel used in total  
Use the  
and  
and hold both keys for one second to save this new  
value to memory and to exit this function. The display  
TOTAL  
V
will indicate  
and then the new value.  
ALr  
Low fuel alarm setting  
TOTAL  
V
GAS  
Fuel remaining in tank  
4
NAVMAN  
FUEL 2100 Installation and Operation Manual  
Setting the low fuel alarm  
Alarm activation  
Use the  
will indicate  
key to select the alarm function. The LCD  
for two seconds and will then display  
If the fuel remaining value drops below the fuel alarm  
value, the alarm will sound and the alarm arrow will  
flash.  
ALr  
the present alarm value. If no alarm value has been  
0FF  
entered the LCD will indicate  
.
FLOW  
^
TOTAL  
V
#
12  
Press any key to mute the alarm. The alarm arrow  
will continue to flash as long as the alarm condition  
remains.  
ALr  
012 0FF  
Resetting the TRIP LOG or  
the TOTAL LOG  
To reset a log, press the  
key until the display  
indicates the name of the log to be reset.  
Press and hold both keys for three seconds. Display  
will show trP or tOt for 2 seconds before resetting  
to zero.  
Press and hold both keys for three seconds and the  
displayed value will begin to flash.  
Press and hold for 3 seconds  
trP tOt  
000  
Press and hold for 3 seconds  
812  
keys to select the desired alarm  
Use the  
and  
value. Press and hold both keys for one second to  
save this new value to memory and to exit this function.  
The display will indicate ALr and then the new value.  
The trip log value may be reset without changing  
the total log value.  
If the total log is reset to zero, then the trip log  
will automatically reset to zero.  
ALr  
814  
Note :  
If the total log exceeds 999 then both it  
and the trip log will be reset to zero.  
#
The arrow pointing at the alarm bell will be activated.  
5
NAVMAN  
FUEL 2100 Installation and Operation Manual  
2 Instrument Setup  
Selecting units of measure  
Calibration  
The FUEL 2100 will indicate fuel values in Litres,  
Imperial gallons or US gallons. To change the current  
setting perform the following steps:  
The fuel transducer supplied with the fuel flow meter  
will provide readings at better than 5% accuracy.  
Individual calibration will increase this level of  
accuracy to better than 2% over a fuel flow range of  
10.0 to 120 litres per hour. Use the following steps to  
calibrate your fuel flow meter:  
1. Power up the unit while holding down the  
key.  
FLOW  
^
TOTAL  
1. Reset the total log value to zero (see previous  
page).  
V
Hold down during power up  
2. Use a known amount of fuel. The larger the  
amount the more accurate the calibration will  
be.  
2. When the unit is on, release the  
key. The  
display will indicate the current display unit with:  
3. Take note of the actual volume of fuel used and  
the fuel used indicated by the total log. If these  
two totals are different the instrument may  
require calibration.  
Imperial Gallons  
ꢀꢁꢂ  
ꢀꢁꢃ  
4. Press and hold the  
key while applying power  
F L O W  
^
US Gallons  
Hold down during power up  
5. Release the  
key. Display will flash current  
total log value.  
Litres  
ꢀꢁꢄ  
3. To select the display unit desired, use the  
260  
or  
and  
keys to change the value.  
4. To exit this mode, press and hold both the  
and  
keys simultaneously for one second.  
6. Use the  
keys to make the display  
indicate the actual volume of fuel used.  
7. Press both keys simultaneously for 1 sec to  
exit.  
Press and hold to exit  
Information will now be indicated in the selected  
display unit.  
Press and hold for 1 second  
The fuel flow meter is now calibrated.  
6
NAVMAN  
FUEL 2100 Installation and Operation Manual  
3 Installation  
WARNING  
IT IS VERYIMPORTANTTO INSTALLAFUELFILTER BETWEEN THE FUELFLOW TRANSDUCER  
AND THE FUEL TANK. THIS FILTER WILL CATCH LARGER PARTICLES OF DIRT FROM THE  
FUELTANKAND PREVENTTHE FINE GAUZE FILTER IN THE FUELFLOW TRANSDUCER FROM  
BECOMING BLOCKEDAS THIS MAY DAMAGE THE ENGINE.  
Location  
Mounting  
The FUEL 2100 is designed for above or below deck  
installation. Select a position that is:  
The instrument panel must be 3mm to 19mm  
(1/8" to 3/4") in thickness.  
On a flat surface  
Drill a 51mm (2") hole in the instrument panel.  
At least 300mm (12") from a compass  
At least 500mm (20") from any radio  
Easy to read by the helmsman and crew  
Protected from physical damage  
Accessible to electrical cable connections  
Remove brackets and insert the instrument so  
the back is flush with the instrument panel.  
Slide the bracket over the instrument and  
tighten the mounting nut until secure.  
Instrument  
Panel  
51mm (2”)  
Hole  
Mounting Nut  
Mounting  
Bracket  
Instrument  
Sealing  
Gasket  
7
NAVMAN  
FUEL 2100 Installation and Operation Manual  
Wiring Connection  
Connect the red wire to the positive supply via  
a 1 amp fuse or a 1 amp circuit breaker.  
Connect the black wire to the electrical ground.  
Keep electrical and transducer cables away  
from alternator or other noise generating  
electrical cables. Avoid connecting the  
instrument to power circuits that share loads  
with ignition, alternators, inverters and radio  
transmitters. Electrical power supply  
connections should always be as short as  
possible.  
Connect the fuel flow transducer to the five pin  
transducer inlet cable.  
BUZZER  
BRACKET  
600mm (24”)  
POWER CORD  
FUJI 5-PIN  
CONNECTOR  
RED  
(+) TERMINAL  
BLACK  
(-) TERMINAL  
Installation of the fuel flow  
transducer  
Drain all the fuel from the flexible fuel line. Cut the  
fuel line and using the fuel hose fixing clips provided  
install the transducer so that the FUEL IN side of the  
transducer connects to the fuel tank.  
The fuel flow transducer is designed for installation  
in  
Coast  
Guard  
approved  
9.5 mm  
(3/8”) flexible fuel line. The transducer MUST be  
installed AFTER the main fuel filter. It should be  
located well away from any area where it will be  
effected by excessive heat or vibration from the  
engine. It is preferable to mount the transducer in a  
vertical position.  
8
NAVMAN  
FUEL 2100 Installation and Operation Manual  
Appendix A - Specifications  
Size  
Mount  
Depth behind face plate 95mm max.  
Fuel Remaining  
51mm diameter hole  
User enters a fuel value into memory via the key  
pad. The quantity of fuel used is automatically  
subtracted from this total. This value remains in  
memory at power down.  
Display  
3-character LCD  
Colour  
Black with texture on bezel.  
Operating Voltage  
8 V DC to 16.5 V DC.  
Backlighting  
Red coloured diffused lighting for display.  
Operating Temperature  
0 to 50°C (32 to 122°F).  
Water Integrity  
Front will withstand direct water spray.  
Current Drain  
70 mA max.  
Alarm  
Audio and visual alarm indicates remaining fuel  
total has dropped below a preset alarm value.  
RF Interference  
<6 dB quieting on any marine radio channel  
(with 3 dB gain antenna) within one metre of the  
instrument. Complies with CE EMC standards  
EN50081-1 and EN50082-1.  
Flow  
2.5 to 160 litres per hour  
0.5 to 43 US gallons per hour  
0.4 to 36 imperial gallons per hour  
Logs  
Logs record fuel used up to 999 display units.  
Total Log is saved in memory at power down.  
Both Trip Log and Total Log can be reset via the  
keypad.  
Display is backlit for  
Night Operation  
NAVMAN  
888  
V
Power  
FUEL  
FLOW  
^
TOTAL  
Change Value Up  
Change Value Down  
9
NAVMAN  
FUEL 2100 Installation and Operation Manual  
Appendix B - Troubleshooting Chart  
No display:  
1. Check DC power connections and DC polarity with voltmeter.  
2. Check fuse.  
No flow reading indicated:  
1. Check connection to flow transducer.  
2. Remove transducer from fuel line, blow through transducer, a whistling noise will indicate the  
turbine is rotating.  
Low flow reading indicated:  
1. Check that the gauze filter is clean. If the filter is not installed fine strands may clog up the  
turbine.  
2. Check calibration is correct.  
High or erratic reading:  
Check fuel connections are well made. Air in fuel lines will cause erratic or high readings.  
10  
NAVMAN  
FUEL 2100 Installation and Operation Manual  
Appendix C - How to contact us  
NORTH AMERICA  
NAVMAN USA INC.  
18 Pine St. Ext.  
ASIA  
China  
Vietnam  
Haidang Co. Ltd.  
Holland  
PLASTIMO HOLLAND BV.  
Peaceful Marine Electronics Co. Ltd.  
Hong Kong, Guangzhou,  
Shanghai, Qindao, Dalian.  
Nashua, NH 03060.  
16A/A1E, Ba thang hai St.  
District 10, Hochiminh City.  
Industrieweg 4-6,  
Ph: +1 603 577 9600  
2871 RP SCHOONHOVEN.  
Ph: +31 182 320 522  
e-mail: [email protected] E210, Huang Hua Gang Ke Mao Ph: +84 8 86321 59  
Street, 81 Xian Lie Zhong Road,  
510070 Guangzhou, China.  
Ph: +86 20 3869 8784  
OCEANIA  
New Zealand  
Absolute Marine Ltd.  
Unit B, 138 Harris Road,  
East Tamaki, Auckland.  
Ph: +64 9 273 9273  
e-mail:  
United Kingdom  
MIDDLE EAST  
Lebanon and Syria  
Letro, Balco Stores,  
Website:www.peaceful-marine.com  
PLASTIMO Mfg. UK Ltd.  
School Lane - Chandlers Ford  
Industrial Estate,  
India  
Moutran Street, Tripoli VIA Beirut.  
Ph: +961 6 624512  
Access India Overseas Pvt  
A-98, Sector 21, Noida, India  
Ph: +91 120 244 2697  
EASTLEIGH - HANTS S053 ADG.  
Ph: +44 23 8026 3311  
Papua New Guinea  
Lohberger Engineering  
Lawes Road, Konedobu  
PO Box 810  
United Arab Emirates  
Kuwait, Oman, Iran & Saudi Arabia  
Abdullah Moh’d Ibrahim  
Trading, opp Creak Rd.  
Baniyas Road, Dubai.  
Indonesia  
Polytech Nusantara  
Sweden, Denmark or Finland  
PLASTIMO NORDIC AB.  
Box 28 - Lundenvägen 2,  
47321 HENAN.  
Graha Paramita 2nd Floor  
Jln Denpasar Raya Blok D2  
Kav 8 Kuningan, Jakarta 12940  
Tel: 021 252 3249  
Port Moresby  
Ph: +675 321 2122  
Ph: +971 4 229 1195  
Ph: +46 304 360 60  
Australia  
NAVMAN AUSTRALIA PTY  
AFRICA  
South Africa  
Korea  
Kumhomarine Technology Co., Ltd.  
#604-842, 2F, 1118-15,  
Janglim1-Dong, Saha-Gu  
Busan, Korea  
Spain  
Limited  
Pertec (Pty) Ltd Coastal,  
Division No.16 Paarden Eiland Rd.  
Paarden Eiland, 7405  
Postal Address: PO Box 527,  
Paarden Eiland 7420  
Cape Town, South Africa.  
Ph: +27 21 511 5055  
PLASTIMO ESPAÑA, S.A.  
Avenida Narcís Monturiol, 17  
08339 VILASSAR DE DALT,  
(Barcelona).  
Unit 6 / 5-13 Parsons St,  
Rozelle, NSW 2039, Australia.  
Ph: +61 2 9818 8382  
Ph: +82 51 293 8589  
Ph: +34 93 750 75 04  
SOUTH AMERICA  
Argentina  
Costanera UNO S.A.  
Av Presidente R Castillo y  
Calle 13  
Maldives  
Maizan Electronics Pte. Ltd.  
8 Sosunmagu Male  
Ph: +960 78 2444  
e-mail:  
Portugal  
EUROPE  
France, Belgium and  
Switzerland  
PLASTIMO INTERNATIONAL  
15, rue Ingénieur Verrière,  
BP435,  
PLASTIMO PORTUGAL  
Avenida de India N°40  
1300-299 Lisbon  
1425 Buenos Aires, Argentina.  
Ph: +54 11 4312 4545  
e-mail:  
Ph: +351 21 362 04 57  
e-mail:  
Singapore  
RIQ PTE Ltd.  
Website:  
56325 Lorient Cedex.  
Ph: +33 2 97 87 36 36  
81, Defu Lane 10, Hah Building,  
#02-00 Singapore 539217  
Ph: +65 6741 3723  
Other countries in Europe  
PLASTIMO INTERNATIONAL  
15, rue Ingénieur Verrière  
BP435  
Brazil  
REALMARINE  
Estrada do Joa 3862,  
CEP2611-020,  
Germany  
56325 Lorient Cedex, France.  
Ph: +33 2 97 87 36 59  
e-mail:  
Taiwan  
PLASTIMO DEUTSCHLAND  
15, rue Ingénieur Verrière  
BP435- 56325 Lorient Cedex.  
Ph: +49 6105 92 10 09  
+49 6105 92 10 10  
Seafirst International Corporation  
No.281, Hou-An Road  
Chien-Chen Dist.  
Barra da Tijuca, Rio de Janeiro,  
Brasil.  
Ph: +55 21 2483 9700  
e-mail:  
Kaohsiung, Taiwan R.O.C.  
Ph: +886 7 831 2688  
REST OF WORLD /  
MANUFACTURERS  
Navman NZ Limited  
+49 6105 92 10 12  
e-mail:  
Equinautic Com Imp Exp de  
Equip Nauticos Ltda.  
Thailand  
Thong Electronics (Thailand)  
13-17 Kawana St. Northcote.  
P.O. Box 68 155 Newton,  
Auckland, New Zealand.  
Ph: +64 9 481 0500  
e-mail:  
Av. Diario de Noticias 1997 CEP  
90810-080, Bairro Cristal, Porto  
Alegre - RS, Brasil.  
Company Ltd.  
Italy  
PLASTIMO ITALIA  
923/588 Thaprong Road,  
Mahachai,  
Ph: +55 51 3242 9972  
e-mail:  
Nuova Rade spa, Via del Pontasso 5  
I-16015 CASELLA SCRIVIA (GE).  
Ph: +39 1096 8011  
Muang, Samutsakhon 74000,  
Thailand.  
Ph: +66 34 411 919  
Made in New Zealand  
MN000207A  
NAVMAN  
Lat 36° 48.404’S  

Whynter Automobile Parts Arc 14fil3m User Manual
Trane Air Conditioner Vav In 24 User Manual
Toshiba E Studio203 User Manual
NEC NP510WS User Manual
LG 22MT45A User Manual
KENWOOD KDC MP6026 User Manual
DELL S2421HS User Manual
CRYSTAL VIDEO PRO 800 CC8980 User Manual
CRAFTSMAN 113.170370 User Manual1
BROTHER HL L2315DW 02 User Manual