FUEL 2100
Installation and
Operation Manual
English .............3
Français ......... 11
Español ..........19
Deutsch .......... 27
Nederlands .... 35
Svenska ......... 43
Suomi .............51
NAVMAN
Contents
1 Operation ......................................................................................................... 4
Fuel Flow ........................................................................................................................... 4
Other Fuel Functions ......................................................................................................... 4
Changing the fuel remaining value ..................................................................................... 4
Setting the low fuel alarm ................................................................................................... 5
Alarm activation ................................................................................................................. 5
Resetting the TRIP LOG or the TOTAL LOG ..................................................................... 5
2 Instrument Setup ............................................................................................. 6
Selecting units of measure................................................................................................. 6
Calibration ......................................................................................................................... 6
3 Installation ....................................................................................................... 7
Location ............................................................................................................................. 7
Mounting ........................................................................................................................... 7
Wiring Connection ............................................................................................................. 8
Installation of the fuel flow transducer ................................................................................ 8
Appendix A - Specifications .............................................................................. 9
Appendix B - Troubleshooting Chart .............................................................. 10
Appendix C - How to contact us ..................................................................... 59
Important
It is the owner’s sole responsibility to install and use the instrument and transducer/s in a manner that will
not cause accidents, personal injury or property damage. The user of this product is solely responsible for
observing safe boating practices.
NAVMAN NZ LIMITED DISCLAIMSALL LIABILITY FORANY USE OF THIS PRODUCT INAWAYTHAT
MAY CAUSE ACCIDENTS, DAMAGE OR THAT MAY VIOLATE THE LAW.
This manual represents the FUEL 2100 as at the time of printing. Navman NZ Limited reserves the right
to make changes to specifications without notice.
Governing Language: This statement, any instruction manuals, user guides and other information relating
to the product (Documentation) may be translated to, or has been translated from, another language
(Translation). In the event of any conflict between any Translation of the Documentation, the English
language version of the Documentation will be the official version of the Documentation.
Copyright © 2002 Navman NZ Limited, New Zealand.All rights reserved. NAVMAN is a registered trademark
of Navman NZ Limited.
3
NAVMAN
FUEL 2100 Installation and Operation Manual
1 Operation
Fuel Flow
Changing the fuel remaining value
Press the
rate.
key to display the current fuel flow
To change the value of fuel remaining in the tank,
press the
key until the display indicates
for
two seconds and then displays the current value.
FLOW
^
TOTAL
V
FLOW
^
TOTAL
V
#
ꢀꢁꢂꢀ
ꢀꢁꢂ
ꢃꢄꢅꢆ
Other Fuel Functions
Press the
key to cycle through the possible
key is pressed the display
functions. Each time the
will show an identifier for 2 seconds before the value
is displayed.
Press and hold both keys for three seconds and the
displayed value will begin to flash.
Press and hold for 3 seconds
Fuel used on trip
TOTAL
V
260
keys to change the value. Press
tOt
Fuel used in total
Use the
and
and hold both keys for one second to save this new
value to memory and to exit this function. The display
TOTAL
V
will indicate
and then the new value.
ALr
Low fuel alarm setting
TOTAL
V
GAS
Fuel remaining in tank
4
NAVMAN
FUEL 2100 Installation and Operation Manual
Setting the low fuel alarm
Alarm activation
Use the
will indicate
key to select the alarm function. The LCD
for two seconds and will then display
If the fuel remaining value drops below the fuel alarm
value, the alarm will sound and the alarm arrow will
flash.
ALr
the present alarm value. If no alarm value has been
0FF
entered the LCD will indicate
.
FLOW
^
TOTAL
V
#
ꢀ
12
Press any key to mute the alarm. The alarm arrow
will continue to flash as long as the alarm condition
remains.
ALr
012 0FF
Resetting the TRIP LOG or
the TOTAL LOG
To reset a log, press the
key until the display
indicates the name of the log to be reset.
Press and hold both keys for three seconds. Display
will show trP or tOt for 2 seconds before resetting
to zero.
Press and hold both keys for three seconds and the
displayed value will begin to flash.
Press and hold for 3 seconds
trP tOt
000
Press and hold for 3 seconds
812
keys to select the desired alarm
Use the
and
value. Press and hold both keys for one second to
save this new value to memory and to exit this function.
The display will indicate ALr and then the new value.
The trip log value may be reset without changing
the total log value.
If the total log is reset to zero, then the trip log
will automatically reset to zero.
ALr
814
Note :
If the total log exceeds 999 then both it
and the trip log will be reset to zero.
#
The arrow pointing at the alarm bell will be activated.
5
NAVMAN
FUEL 2100 Installation and Operation Manual
2 Instrument Setup
Selecting units of measure
Calibration
The FUEL 2100 will indicate fuel values in Litres,
Imperial gallons or US gallons. To change the current
setting perform the following steps:
The fuel transducer supplied with the fuel flow meter
will provide readings at better than 5% accuracy.
Individual calibration will increase this level of
accuracy to better than 2% over a fuel flow range of
10.0 to 120 litres per hour. Use the following steps to
calibrate your fuel flow meter:
1. Power up the unit while holding down the
key.
FLOW
^
TOTAL
1. Reset the total log value to zero (see previous
page).
V
Hold down during power up
2. Use a known amount of fuel. The larger the
amount the more accurate the calibration will
be.
2. When the unit is on, release the
key. The
display will indicate the current display unit with:
3. Take note of the actual volume of fuel used and
the fuel used indicated by the total log. If these
two totals are different the instrument may
require calibration.
Imperial Gallons
ꢀꢁꢂ
ꢀꢁꢃ
4. Press and hold the
key while applying power
F L O W
^
US Gallons
Hold down during power up
5. Release the
key. Display will flash current
total log value.
Litres
ꢀꢁꢄ
3. To select the display unit desired, use the
260
or
and
keys to change the value.
4. To exit this mode, press and hold both the
and
keys simultaneously for one second.
6. Use the
keys to make the display
indicate the actual volume of fuel used.
7. Press both keys simultaneously for 1 sec to
exit.
Press and hold to exit
Information will now be indicated in the selected
display unit.
Press and hold for 1 second
The fuel flow meter is now calibrated.
6
NAVMAN
FUEL 2100 Installation and Operation Manual
3 Installation
WARNING
IT IS VERYIMPORTANTTO INSTALLAFUELFILTER BETWEEN THE FUELFLOW TRANSDUCER
AND THE FUEL TANK. THIS FILTER WILL CATCH LARGER PARTICLES OF DIRT FROM THE
FUELTANKAND PREVENTTHE FINE GAUZE FILTER IN THE FUELFLOW TRANSDUCER FROM
BECOMING BLOCKEDAS THIS MAY DAMAGE THE ENGINE.
Location
Mounting
The FUEL 2100 is designed for above or below deck
installation. Select a position that is:
The instrument panel must be 3mm to 19mm
(1/8" to 3/4") in thickness.
•
•
•
•
•
•
On a flat surface
•
•
Drill a 51mm (2") hole in the instrument panel.
At least 300mm (12") from a compass
At least 500mm (20") from any radio
Easy to read by the helmsman and crew
Protected from physical damage
Accessible to electrical cable connections
Remove brackets and insert the instrument so
the back is flush with the instrument panel.
•
Slide the bracket over the instrument and
tighten the mounting nut until secure.
Instrument
Panel
51mm (2”)
Hole
Mounting Nut
Mounting
Bracket
Instrument
Sealing
Gasket
7
NAVMAN
FUEL 2100 Installation and Operation Manual
Wiring Connection
•
•
Connect the red wire to the positive supply via
a 1 amp fuse or a 1 amp circuit breaker.
Connect the black wire to the electrical ground.
•
Keep electrical and transducer cables away
from alternator or other noise generating
electrical cables. Avoid connecting the
instrument to power circuits that share loads
with ignition, alternators, inverters and radio
transmitters. Electrical power supply
connections should always be as short as
possible.
Connect the fuel flow transducer to the five pin
transducer inlet cable.
BUZZER
BRACKET
600mm (24”)
POWER CORD
FUJI 5-PIN
CONNECTOR
RED
(+) TERMINAL
BLACK
(-) TERMINAL
Installation of the fuel flow
transducer
Drain all the fuel from the flexible fuel line. Cut the
fuel line and using the fuel hose fixing clips provided
install the transducer so that the FUEL IN side of the
transducer connects to the fuel tank.
The fuel flow transducer is designed for installation
in
Coast
Guard
approved
9.5 mm
(3/8”) flexible fuel line. The transducer MUST be
installed AFTER the main fuel filter. It should be
located well away from any area where it will be
effected by excessive heat or vibration from the
engine. It is preferable to mount the transducer in a
vertical position.
8
NAVMAN
FUEL 2100 Installation and Operation Manual
Appendix A - Specifications
•
Size
Mount
Depth behind face plate 95mm max.
•
Fuel Remaining
51mm diameter hole
User enters a fuel value into memory via the key
pad. The quantity of fuel used is automatically
subtracted from this total. This value remains in
memory at power down.
Display
3-character LCD
•
•
•
•
Colour
Black with texture on bezel.
•
•
•
•
Operating Voltage
8 V DC to 16.5 V DC.
Backlighting
Red coloured diffused lighting for display.
Operating Temperature
0 to 50°C (32 to 122°F).
Water Integrity
Front will withstand direct water spray.
Current Drain
70 mA max.
Alarm
Audio and visual alarm indicates remaining fuel
total has dropped below a preset alarm value.
RF Interference
<6 dB quieting on any marine radio channel
(with 3 dB gain antenna) within one metre of the
instrument. Complies with CE EMC standards
EN50081-1 and EN50082-1.
•
•
Flow
2.5 to 160 litres per hour
0.5 to 43 US gallons per hour
0.4 to 36 imperial gallons per hour
Logs
Logs record fuel used up to 999 display units.
Total Log is saved in memory at power down.
Both Trip Log and Total Log can be reset via the
keypad.
Display is backlit for
Night Operation
NAVMAN
888
V
Power
FUEL
FLOW
^
TOTAL
Change Value Up
Change Value Down
9
NAVMAN
FUEL 2100 Installation and Operation Manual
Appendix B - Troubleshooting Chart
No display:
1. Check DC power connections and DC polarity with voltmeter.
2. Check fuse.
No flow reading indicated:
1. Check connection to flow transducer.
2. Remove transducer from fuel line, blow through transducer, a whistling noise will indicate the
turbine is rotating.
Low flow reading indicated:
1. Check that the gauze filter is clean. If the filter is not installed fine strands may clog up the
turbine.
2. Check calibration is correct.
High or erratic reading:
Check fuel connections are well made. Air in fuel lines will cause erratic or high readings.
10
NAVMAN
FUEL 2100 Installation and Operation Manual
Appendix C - How to contact us
e-mail: [email protected]
NORTH AMERICA
NAVMAN USA INC.
18 Pine St. Ext.
ASIA
China
Vietnam
Haidang Co. Ltd.
Holland
PLASTIMO HOLLAND BV.
Peaceful Marine Electronics Co. Ltd.
Hong Kong, Guangzhou,
Shanghai, Qindao, Dalian.
Nashua, NH 03060.
16A/A1E, Ba thang hai St.
District 10, Hochiminh City.
Industrieweg 4-6,
Ph: +1 603 577 9600
2871 RP SCHOONHOVEN.
Ph: +31 182 320 522
Street, 81 Xian Lie Zhong Road,
510070 Guangzhou, China.
Ph: +86 20 3869 8784
e-mail: [email protected]
e-mail: [email protected]
OCEANIA
New Zealand
Absolute Marine Ltd.
Unit B, 138 Harris Road,
East Tamaki, Auckland.
Ph: +64 9 273 9273
e-mail:
United Kingdom
MIDDLE EAST
Lebanon and Syria
Letro, Balco Stores,
Website:www.peaceful-marine.com
PLASTIMO Mfg. UK Ltd.
School Lane - Chandlers Ford
Industrial Estate,
India
Moutran Street, Tripoli VIA Beirut.
Ph: +961 6 624512
e-mail: [email protected]
Access India Overseas Pvt
A-98, Sector 21, Noida, India
Ph: +91 120 244 2697
e-mail: [email protected]
EASTLEIGH - HANTS S053 ADG.
Ph: +44 23 8026 3311
e-mail: [email protected]
Papua New Guinea
Lohberger Engineering
Lawes Road, Konedobu
PO Box 810
United Arab Emirates
Kuwait, Oman, Iran & Saudi Arabia
Abdullah Moh’d Ibrahim
Trading, opp Creak Rd.
Baniyas Road, Dubai.
Indonesia
Polytech Nusantara
Sweden, Denmark or Finland
PLASTIMO NORDIC AB.
Box 28 - Lundenvägen 2,
47321 HENAN.
Graha Paramita 2nd Floor
Jln Denpasar Raya Blok D2
Kav 8 Kuningan, Jakarta 12940
Tel: 021 252 3249
Port Moresby
Ph: +675 321 2122
e-mail: [email protected]
Ph: +971 4 229 1195
e-mail: [email protected]
Ph: +46 304 360 60
e-mail: [email protected]
Australia
NAVMAN AUSTRALIA PTY
AFRICA
South Africa
Korea
Kumhomarine Technology Co., Ltd.
#604-842, 2F, 1118-15,
Janglim1-Dong, Saha-Gu
Busan, Korea
Spain
Limited
Pertec (Pty) Ltd Coastal,
Division No.16 Paarden Eiland Rd.
Paarden Eiland, 7405
Postal Address: PO Box 527,
Paarden Eiland 7420
Cape Town, South Africa.
Ph: +27 21 511 5055
e-mail: [email protected]
PLASTIMO ESPAÑA, S.A.
Avenida Narcís Monturiol, 17
08339 VILASSAR DE DALT,
(Barcelona).
Unit 6 / 5-13 Parsons St,
Rozelle, NSW 2039, Australia.
Ph: +61 2 9818 8382
e-mail: [email protected]
Ph: +82 51 293 8589
e-mail: [email protected]
Ph: +34 93 750 75 04
e-mail: [email protected]
SOUTH AMERICA
Argentina
Costanera UNO S.A.
Av Presidente R Castillo y
Calle 13
Maldives
Maizan Electronics Pte. Ltd.
8 Sosunmagu Male
Ph: +960 78 2444
e-mail:
Portugal
EUROPE
France, Belgium and
Switzerland
PLASTIMO INTERNATIONAL
15, rue Ingénieur Verrière,
BP435,
PLASTIMO PORTUGAL
Avenida de India N°40
1300-299 Lisbon
1425 Buenos Aires, Argentina.
Ph: +54 11 4312 4545
e-mail:
Ph: +351 21 362 04 57
e-mail:
Singapore
RIQ PTE Ltd.
Website:
56325 Lorient Cedex.
Ph: +33 2 97 87 36 36
e-mail: [email protected]
81, Defu Lane 10, Hah Building,
#02-00 Singapore 539217
Ph: +65 6741 3723
e-mail: [email protected]
Other countries in Europe
PLASTIMO INTERNATIONAL
15, rue Ingénieur Verrière
BP435
Brazil
REALMARINE
Estrada do Joa 3862,
CEP2611-020,
Germany
56325 Lorient Cedex, France.
Ph: +33 2 97 87 36 59
e-mail:
Taiwan
PLASTIMO DEUTSCHLAND
15, rue Ingénieur Verrière
BP435- 56325 Lorient Cedex.
Ph: +49 6105 92 10 09
+49 6105 92 10 10
Seafirst International Corporation
No.281, Hou-An Road
Chien-Chen Dist.
Barra da Tijuca, Rio de Janeiro,
Brasil.
Ph: +55 21 2483 9700
e-mail:
Kaohsiung, Taiwan R.O.C.
Ph: +886 7 831 2688
e-mail: [email protected]
REST OF WORLD /
MANUFACTURERS
Navman NZ Limited
+49 6105 92 10 12
e-mail:
Equinautic Com Imp Exp de
Equip Nauticos Ltda.
Thailand
Thong Electronics (Thailand)
13-17 Kawana St. Northcote.
P.O. Box 68 155 Newton,
Auckland, New Zealand.
Ph: +64 9 481 0500
e-mail:
Av. Diario de Noticias 1997 CEP
90810-080, Bairro Cristal, Porto
Alegre - RS, Brasil.
Company Ltd.
Italy
PLASTIMO ITALIA
923/588 Thaprong Road,
Mahachai,
Ph: +55 51 3242 9972
e-mail:
Nuova Rade spa, Via del Pontasso 5
I-16015 CASELLA SCRIVIA (GE).
Ph: +39 1096 8011
e-mail: [email protected]
Muang, Samutsakhon 74000,
Thailand.
Ph: +66 34 411 919
Made in New Zealand
MN000207A
NAVMAN
Lat 36° 48.404’S
|