Mitsubishi Mr Slim Pc36ek User Manual

®
Mr.Slim  
Ductless Air Conditioning And  
Heat Pump Product Guide  
MITSUBISHI ELECTRONICS AMERICA, INC.  
HVAC DIVISION  
3100 AVALON RIDGE PL. STE. 200,NORCROSS, GA 30071  
CALL: 770-613-5840 OR 800-433-4822 (PRESS 3), FAX: 800-889-9904  
® DUCTLESS AIR CONDITIONERS  
AND HEAT PUMPS  
Mr.Slim  
Mr. Slim systems are unlike any other  
products in the HVAC category. Actually they’re  
a category in themselves because Mr. Slim is  
probably the most unique innovation in air  
comfort in two decades and one that has made  
us the worldwide leader in ductless.  
We designed Mr. Slim air conditioners and  
heat pumps to solve cooling and heating  
problems that other systems have never  
addressed, specifically spot or zone cooling  
and heating especially in retrofit situations.  
These are voids in comfort that central air and  
room air simply can’t fill economically and  
attractively.  
Where Mr. Slim Fits.  
You’ll often encounter a hot or cold spot in  
existing buildings that already have large  
central systems. Is the answer to remodel and  
make way for more ductwork? Obviously that’s  
a small fortune. Should you opt for room air?  
It’s unsightly at best, expensive to run, and a  
real security hazard.  
How Mr. Slim  
Works.  
Basically Mr. Slim is two units: an indoor air  
handler and an outdoor compressor unit.  
The two connect via refrigerant lines  
through a three inch diameter opening in the  
wall or ceiling. In fact that’s the toughest part of  
installation: one hole.  
Now you’re beginning to see how Mr. Slim  
fits in. It’s the ideal supplemental system for  
cooling or heating those smaller zones with  
absolutely no ductwork, no remodeling, and  
few disruptions to business and traffic.  
You can locate the compact outdoor  
compressor unit anywhere up to 164 feet away  
from the air handler on select models: in many  
cases. Many models have a front service panel  
that clearly exposes all connections.  
Our system is energy  
efficient and whisper quiet.  
Its remote control keeps all  
operating functions and  
data within a glance and  
in easy reach. And it  
neatly tucks away into  
corners, blending in  
The indoor air handler is as easy to install  
as a ceiling fan. And both the indoor and  
outdoor units are microprocessor controlled.  
Simple remotes let you control all functions.  
with the room’s decor.  
COMFORT MADE SIMPLE.  
MITSUBISHI ELECTRONICS  
1
HVAC DIVISION  
Medium-to-large capacity cooling and heating  
for large area commercial applications  
15  
PC/PCH  
LARGE AREA COOLING AND HEATING MADE SIMPLE.  
Mr. Slim heat pumps also feature automatic  
Intelligent Remote Controller  
cooling/heating changeover for simple control  
Highly advanced microprocessor technology is and lower maintenance. You never have to  
one reason why Mitsubishi leads the air comfort readjust the unit.  
category. This ultrathin microprocessor remote  
controller with LCD display gives you a variety of  
functions and options to keep room comfort  
perfectly balanced. It lets you  
check Mr. Slim’s operating  
conditions with just a glance. In the  
rare case of a malfunction the self-  
diagnostic system even indicates  
specific problems for easy repair.  
Air Flow  
• Computerized Dehumidification  
These units offer a wide choice of air flow  
directions. In the heating mode the vanes  
automatically set the flow of warm air downward  
at an angle of seventy degrees fahrenheit. In the  
cooling mode the vanes automatically set the  
flow of cool air outward (horizontally). But you  
can override the automatic setting to blend air  
flow. Four directions may be selected: one  
hundred percent downward, eighty percent  
downward and twenty percent horizontal, sixty  
percent downward, and forty percent horizontal  
or one hundred percent horizontal. Jumbo  
louvers automatically rotate right and left for  
uniform air distribution over your entire space.  
• Operation Mode Setting (Heat, Auto, Cool/Dry)  
Temperature Setting (in units of two  
degrees fahrenheit.)  
• Self-Diagnostic Display  
• Room Temperature Display  
• Twenty-Four Hour On/Off Timer  
• Fan Speed Indicator  
• Auto/Swing Vane Operation  
• Memory (for storing operation functions)  
• Low Ambient Operation  
• Whisper-Quiet Operation  
• EMS Gateway Available To Management System  
Via RS-232 Cable  
Outdoor Compressor Unit  
Redi-Charged System  
Mr. Slim outdoor compressor units are  
extremely efficient and reliable and true space-  
savers.  
Mr. Slim “P” series features the industry’s  
first redi-charged refrigerant system. There’s no  
longer any need to adjust the amount of  
refrigerant to match the piping length on-site  
unless lines exceed one hundred feet. You’ll  
see a major reduction in installation time and  
labor costs. Plus you can always count on Mr.  
Slim’s reliability from day one because it’s  
thoroughly charged and tested at the factory.  
You know it’s going to work.  
These models can be installed up to 164  
feet away from the indoor unit. They connect  
simply through a single three-to-four inch  
opening in the wall or ceiling. No ductwork or  
remodeling is necessary. As many as ten units  
can be installed in a row for major space  
savings.  
Outdoor units are designed with a front-  
access service panel that provides easy access  
to all maintenance points.  
Hot Start System  
Mr. Slim heat pumps provide warmth right  
from the beginning. At the start of heating and  
during defrosting, a very low fan speed  
prevents the unit from blowing cold air into  
the room. And a microprocessor-controlled  
booster heater speeds the warming process.  
These units operate in outdoor  
temperatures as low as zero degrees fahrenheit  
when the optional wind baffle is  
installed. So you can cool spaces  
such as computer rooms year  
round.  
16  
Air Conditioners  
Heat Pumps  
PC24EK  
PCH24EK  
PC24EK  
Cooling Capacity: 24,000 BTU/h  
SEER: 10.3  
PCH24EK  
Cooling capacity: 24,000 BTU/h  
SEER: 10.3  
Dimensions:  
W:50-7/16”, D:26-13/16”, H:10-1/8”  
Heating capacity:  
27,000 BTU/h (33,500 w/ aux. booster heat)  
HSPF: 7.1  
Dimensions: W:50-7/16”, D:26-13/16”, H:10-1/8”  
PC30EK  
Cooling capacity: 31,000 BTU/h  
SEER: 10.4  
PCH30EK  
Cooling capacity: 30,000 BTU/h  
SEER: 10.0  
Dimensions:  
W:50-7/16”, D:26-13/16”, H:10-1/8”  
Heating capacity:  
33,000 BTU/h (41,500 w/ aux. booster heat)  
HSPF: 7.1  
Dimensions: W:50-7/16”, D:26-13/16”, H:10-1/8”  
PC36EK  
Cooling capacity: 36,500 BTU/h  
SEER: 10.2  
PCH36EK  
Cooling capacity: 35,400 BTU/h  
SEER: 10.4  
Dimensions:  
W:62-1/4”, D:26-13/16”, H:10-1/8”  
Heating capacity:  
38,000 BTU/h (47,600 w/ aux. booster heat)  
HSPF: 7.4  
Dimensions: W:62-1/4”, D:26-13/16”, H:10-1/8”  
PC42EK  
Cooling capacity: 42,500 BTU/h  
SEER 10.0  
PCH42EK  
Cooling capacity: 42,000 BTU/h  
SEER: 10.0  
Dimensions:  
W:62-1/4”, D:26-13/16”, H:10-1/8”  
Heating capacity:  
43,000 BTU/h (52,600 w/ aux. booster heat)  
HSPF: 7.3  
Dimensions: W:62-1/4”, D:26-13/16”, H:10-1/8”  
beneath the base. This easy-access design lets  
you arrange and install a number of units in a  
small area.  
Simplified Installation  
Mr. Slim’s streamlined design makes indoor  
units adaptable to an almost infinite variety of  
room configurations. They’re simple to mount,  
and they require a minimum of wiring. Naturally  
they’re not only efficient but also whisper-quiet.  
You’ll hardly hear them running.  
Warranty  
Mitsubishi is so confident of the reliability  
of Mr. Slim® Systems that we offer a six year  
warranty on the compressor and a one year  
warranty on all other parts.  
Refrigerant lines may be connected to the  
outdoor unit from the front, rear, or side or  
17  
PC24EK  
24,000  
PC30EK  
31,000  
PC36EK  
36,500  
PC42EK  
42,500  
PCH24EK  
24,000  
27,000(33,500)  
18,400(24,900)  
2.46  
PCH30EK  
30,000  
33,000(41,500)  
18,000(26,500)  
3.06  
PCH36EK  
35,400  
38,000(47,600)  
19,600(29,200)  
3.53  
PCH42EK  
42,000  
43,000(52,600)  
24,800(34,400)  
4.37  
ITEM  
MODEL  
Cooling *1 BTU/h  
Heating *1 BTU/h  
Heating *2 BTU/h  
Cooling *1 kW  
Heating *1 kW  
Heating *2 kW  
*1  
Capacity  
Power  
2.43  
3.1  
3.8  
4.4  
Consumption  
2.42(4.32)  
2.1(4.0)  
9.8  
3.13(5.63)  
2.6(5.1)  
9.8  
3.4(6.2)  
2.7(5.5)  
10.0  
4.3(7.1)  
3.2(6.1)  
9.6  
EER  
9.9  
10.0  
10.4  
9.6  
9.7  
SEER  
HSPF  
COP  
10.3  
10.2  
10.0  
10.3  
10.0  
10.4  
10.0  
7.1  
7.1  
7.4  
7.3  
Heating *1  
Heating *2  
3.3  
3.1  
3.3  
3.1  
2.6  
2.4  
2.1  
2.3  
INDOOR UNIT  
External Finish  
Power Supply  
PC24EK  
PC30EK  
PC36EK  
PC42EK  
PCH24EK  
PCH30EK  
PCH36EK  
PCH42EK  
Munsell 2.5Y 8/0.3 & N2  
V, phase, Hz  
115, 1, 60  
15  
230, 1, 60  
25  
Max. Fuze Size (time delay)  
A
15  
3
15  
3
15  
12  
20  
15  
25  
15  
25  
Min. Ampacity  
Fan Motor  
3
3
17  
F.L.A.  
A (kW)  
CFM  
1.8  
1.8  
2.1  
2.4  
0.7  
0.7  
1.3  
1.3  
12(2.8)  
1,270-990  
1,100-860  
12.3  
Auxiliary Heater  
Airflow Hi-Lo  
8.4(1.9)  
920-740  
830-670  
7.0  
10.8(2.5)  
920-740  
830-670  
9.1  
12(2.8)  
1,270-990  
1,100-860  
10.9  
Dry  
1,050-850  
900-730  
7.2  
1,050-850  
900-730  
9.6  
1,270-990  
1,100-860  
11.1  
1,270-990  
1,100-860  
12.6  
Wet  
CFM  
Moisture Removal  
Pints/h  
Sound Pressure Level Hi-Lo dB(A)  
Cond. Drain Connection OD in.  
50-43  
1
50-43  
1
52-44  
1
52-44  
50-43  
1
50-43  
1
51-45  
1
51-45  
1
1
W
D
in.  
in.  
50-7/16  
26-13/16  
10-1/8  
93  
50-7/16  
26-13/16  
10-1/8  
93  
62-1/4  
26-13/16  
10-1/8  
115  
62-1/4  
26-13/16  
10-1/8  
115  
50-7/16  
26-13/16  
10-1/8  
97  
50-7/16  
26-13/16  
10-1/8  
97  
62-1/4  
26-13/16  
10-1/8  
119  
62-1/4  
26-13/16  
10-1/8  
119  
Dimensions  
H
in.  
Weight  
lbs.  
OUTDOOR UNIT  
External Finish  
PU24EK  
PU30EK  
PU36EK  
PU42EK  
Munsell 5Y 7/1  
56  
PU24EK  
PU30EK  
PU36EK  
PU42EK  
Sound Pressure Level  
Power Supply  
Max. Fuze Size (time delay)  
dB(A)  
55  
55  
55  
55  
55  
55  
53  
40  
V, phase, Hz  
230, 1, 60  
A
20  
20  
30  
22  
30  
27  
40  
16  
20  
20  
30  
22  
30  
27  
Min. Ampacity  
Fan Motor  
16  
F.L.A.  
0.65+0.65  
NH33NBD  
14  
0.65+0.65  
NH41NAD  
17.5  
0.75+0.75  
NH47NAD  
20  
0.8+0.8  
NH569NXA  
11.5  
0.65+0.65  
NH33NBD  
14  
0.75+0.75  
NH41NAD  
17.5  
0.75+0.75  
NH47NAD  
20  
0.8+0.8  
Model (Type)  
R.L.A.11.5  
L.R.A.54  
NH569NXA  
Compressor  
73  
87  
105  
54  
73  
87  
105  
Crankcase Heater  
Refrigerant Control  
Defrost method  
W
A(W)  
.17(39)  
.17(39)  
.17(39)  
.17(39)  
.17(39)  
.17(39)  
.17(39)  
.17(39)  
Capillary Tube  
34-1/4  
11-5/8  
49-9/16  
207  
Reverse Cycle  
38-3/16  
in.  
34-1/4  
11-5/8  
49-9/16  
208  
38-3/16  
13-9/16  
49-9/16  
220  
38-3/16  
13-9/16  
49-9/16  
260  
34-1/4  
11-5/8  
49-9/16  
202  
38-3/16  
13-9/16  
49-9/16  
246  
38-3/16  
13-9/16  
49-9/16  
268  
Dimensions  
D
H
in.  
13-9/16  
in.  
49-9/16  
Weight  
lbs.  
245  
REMOTE CONTROLLER  
Control Voltage (by built- in transformer)  
With Indoor Unit  
Indoor unit-remote controller: DC 12V, Indoor unit-outdoor unit: DC 12V  
Figures in parentheses include auxiliary heat.  
* For 208 volt applications refer to Technical And Service Manual for ratings.  
18  
Medium-to-large capacity cooling and heating  
for large area commercial applications.  
19  
PL/PLH  
LARGE AREA COOLING AND HEATING MADE SIMPLE.  
Mr. Slim heat pumps also feature automatic  
cooling/heating changeover for simple control  
and lower maintenance. You never have to  
readjust the unit.  
Intelligent Remote Controller  
Highly advanced microprocessor technology  
is one reason why Mitsubishi leads the air  
comfort category. This ultra-thin microprocessor  
remote controller with LCD display gives you a  
variety of functions and options to keep room  
comfort perfectly balanced. It lets you check Mr.  
Slim’s operating conditions with  
- W AY AIR FLO W  
4
O N E PATTERN  
- W AY AIR FLO W  
just a glance. In the rare case of  
a malfunction the self-diagnostic  
system even indicates specific  
problems for easy repair.  
3
FO UR PATTERN S  
- W AY AIR FLO W  
2
SIX PATTERN S (Ex ce p t PL/ PLH3 0  
3 6  
4 2 FK)  
• Computerized Dehumidification  
• Operation Mode Setting (Heat, Auto, Cool/Dry)  
Temperature Setting (in units of two  
degrees fahrenheit.)  
Air Flow  
These ceiling cassettes offer multi-  
directional air flow in a number of various  
patterns to direct heat or cool air where you  
need it most. You can use two, three, or four  
vents and even set the vents for a narrow or  
wide breeze, depending on whether you prefer  
a strong, directed stream of air or a gentle  
breeze over a wide area. Air outlet vanes inside  
the vents automatically swing up and down for  
uniform air distribution.  
• Self-Diagnostic Display  
• Room Temperature Display  
• Twenty-Four Hour On/Off Timer  
• Fan Speed Indicator  
• Auto/Swing Vane Operation  
• Memory (for storing operation functions)  
• Low Ambient Operation  
• Whisper-Quiet Operation  
• EMS Gateway Available To Management System  
Via RS-232 Cable  
Redi-Charged System  
Mr. Slim “P” Series features the industry’s  
first redi-charged refrigerant system. There is  
no need to adjust the amount of refrigerant to  
match the piping length on-site unless lines  
exceed 100 feet. You’ll see a major reduction in  
installation time and labor costs. Plus you can  
always count on Mr. Slim’s reliability from day  
one because they’re thoroughly charged and  
tested at the factory. You know it’s going to  
work.  
Outdoor Compressor Unit  
Mr. Slim outdoor compressor units are  
extremely efficient and reliable and true space-  
savers.  
These models can be installed up to 164  
feet away from the indoor unit. They connect  
simply through a single three inch opening in  
the wall or ceiling. No ductwork or remodeling is  
necessary. As many as ten units can be  
installed in a row for major space savings.  
Hot Start System  
Outdoor units are designed with a front-  
access service panel that provides easy access  
to all maintenance points.  
Mr. Slim heat pumps provide warmth right  
from the beginning. At the start of heating and  
after defrosting, a very low fan speed prevents  
the unit from blowing cold air into the room. And  
a microprocessor controlled booster heater  
speeds the warming process.  
These  
units  
operate  
in  
outdoor  
temperatures as low as zero degrees  
fahrenheit. when the optional wind  
baffle is installed. You can,  
therefore, cool spaces such as  
computer rooms year round.  
20  
PL34FK  
Cooling capacity: 32,400 BTU/h  
SEER: 10.0  
Air Conditioners  
Cassette Dimensions:  
W:52-3/4” D:32-1/4” H:10-1/8”  
PL42FK  
Cooling capacity: 42,500 BTU/h  
SEER: 10.0  
Cassette Dimensions:  
W:52-3/4” D:32-1/4” H:10-1/8”  
PL12FK  
PLH30FK  
PL12FK  
PLH30FK  
Cooling capacity: 30,000 BTU/h  
SEER 10.0  
Heating capacity: 33,000 BTU/h  
(41,200 w/ aux. booster heat)  
HSPF: 7.1  
Cassette Dimensions:  
W:52-3/4” D:32-1/4” H:10-1/8”  
Cooling capacity: 12,300 BTU/h  
SEER: 10.4  
Cassette Dimensions:  
W:32-1/4” D:32-1/4” H:10-1/8”  
Heat Pumps  
PL18FK  
Cooling capacity: 18,400 BTU/h  
SEER: 10.2  
Cassette Dimensions:  
W:32-1/4” D:32-1/4” H:10-1/8”  
PLH36FK  
Cooling capacity: 35,400 BTU/h  
SEER 10.4  
Heating capacity: 38,000 BTU/h  
(47,600 w/ aux. booster heat)  
HSPF: 7.4  
PL24FK  
Cooling capacity: 23,600 BTU/h  
SEER: 10.0  
Cassette Dimensions:  
W:32-1/4” D:32-1/4” H:10-1/8”  
PLH18FK  
PLH18FK  
Cooling capacity: 17,300 BTU/h  
SEER: 10.3  
Heating capacity: 18,000 BTU/h  
(24,500 w/ aux. booster heat)  
HSPF: 7.0  
Cassette Dimensions:  
W:52-3/4” D:32-1/4” H:10-1/8”  
Cassette Dimensions:  
W:32-1/4” D:32-1/4” H:10-1/8”  
PLH42FK  
Cooling capacity: 42,000 BTU/h  
SEER: 10.0  
Heating capacity: 44,300 BTU/h  
(53,900 w/ aux. booster heat)  
HSPF: 7.3  
Cassette Dimensions:  
W:52-3/4” D:32-1/4” H:10-1/8”  
PLH24FK  
Cooling capacity: 23,100 BTU/h  
SEER 10.3  
Heating capacity: 25,000 BTU/h  
(31,500 w/ aux. booster heat)  
HSPF: 7.1  
PL30FK  
PL30FK  
Cooling capacity: 31,000 BTU/h  
SEER: 10.4  
Cassette Dimensions:  
W:32-1/4” D:32-1/4” H:10-1/8”  
Cassette Dimensions:  
W: 52-3/4” D:32-1/4” H:10-1/8”  
efficient but whisper quiet, too. You’ll hardly hear  
them running.  
Slimmer Indoor Unit And Fresh  
Air Intake  
These models also feature a drain water lift-up  
mechanism that saves space and makes drainage  
pipe connection surprisingly simple.  
The unit is specially designed for neat and tidy  
installation. With minimum on-site work, branch  
ducting and outside air ducting can be installed.  
Refrigerant lines may be connected to the  
outdoor unit from the front, rear, or side or beneath  
the base. This easy-access design lets you  
arrange and install a number of units in a small  
area.  
Branch Duct  
12 Inch  
10 Inch  
Unit Height Drain Height  
Panel Height 1 Inch  
Warranty  
Simplified Installation  
Mitsubishi is so confident of the reliability  
of Mr. Slim® Systems that we offer a six year  
warranty on the compressor and a one year  
warranty on all other parts.  
Mr. Slim Ceiling Cassettes install as easily as  
track lighting and make an extremely neat,  
unobtrusive presentation. They require only a  
minimum of wiring. Naturally they’re not only  
21  
ITEM  
MODEL  
PL12FK PL18FK PL24FK PL30FK PL34FK PL42FK PLH18FK PLH24FK PLH30FK PLH36FK PLH42FK  
Cooling *1 BTU/h  
Heating *1 BTU/h  
Heating *2 BTU/h  
Cooling *1 kW  
12,300  
18,400  
23,600  
31,000  
32,400  
42,500  
17,300  
23,100  
30,000  
35,400  
42,000  
Capacity  
18,000(24,500) 25,000(31,500) 33.000 (41,200) 38,000 (47,600) 44.300 (53,900)  
11,500 (18,000) 16,000(22,500) 20,800(29,000) 19,600 (29,200) 28,300 (37,900)  
Power  
1.23  
1.88  
2.48  
3.10  
3.76  
4.40  
1.77  
2.42  
3.20  
3.53  
4.27  
Consumption Heating *1 kW  
Heating *2 kW  
1.6 (3.5) 2.48 (4.38) 2.97 (5.37) 3.40 (6.2) 4.38 (7.18)  
1.4 (3.3)  
9.8  
2.0 (3.9)  
9.5  
2.6 (5.0) 2.70 (5.5) 3.4 (6.2)  
EER  
*1  
10.0  
10.4  
9.8  
10.2  
9.5  
10.0  
10.0  
10.4  
9.6  
10.0  
9.7  
9.4  
10.0  
7.1  
10.0  
10.4  
9.8  
10.0  
7.3  
SEER  
HSPF  
COP  
10.0  
10.3  
10.3  
7.0  
7.1  
7.4  
Heating *1  
Heating *2  
3.3  
3.0  
3.3  
3.3  
3.0  
2.4  
2.3  
2.3  
2.1  
2.4  
INDOOR UNIT  
PL12FK  
PL18FK PL24FK PL30FK PL34FK  
PL42FK  
PLH18FK  
PLH24FK  
PLH30FK  
PLH36FK  
PLH42FK  
External Finish  
Galvanized sheets with gray heat insulation  
Power Supply V, phase, Hz  
Max. Fuze Size (time delay)  
Min. Ampacity  
115, 1, 60  
230, 1, 60  
25  
A
15  
2.0  
15  
2.0  
0.85  
15  
2.0  
1.1  
15  
2.0  
15  
15  
20  
15  
20  
15  
25  
17  
25  
17  
2.0  
3.0  
17  
Fan Motor  
F.L.A.  
0.75  
1.0 + 1.0 1 .0 + 1 .0 1.2 + 1.2  
0.55  
8.4 (1.9)  
600-390  
540-350  
5.3  
0.6  
0.5 + 0.5  
0.5+0.5  
0.6 + 0.6  
Auxiliary Heater  
Airflow Hi-Lo Dry  
Wet  
A (kW)  
CFM  
1,270-920  
1,200-870  
12.6  
8.4 (1.9) 11.0 (2.4) 12.0 (2.8) 12.0 (2.8)  
570-540  
420-400  
3.8  
680-460 750-550 1,170-850  
650-440 660-480 1 ,090-790  
1,170-850  
1,090-790  
10.9  
640-420  
580-380  
7.0  
1,060-670 1,060-670 1,090-780  
CFM  
950-600  
9.1  
950-600  
10.9  
980-700  
12.3  
Moisture Removal  
Pints/h  
5.3  
6.8  
9.6  
Sound Pressure Level Hi-Lo dB(A)  
Cond. Drain Connection OD in.  
43-35  
45-38  
47-39  
49-41  
49-41  
49-42  
45-38  
47-39  
49-41  
49-41  
49-42  
1-1/4  
Cassette  
W
D
in.  
in.  
32-1/4  
32-1/4  
32-1/4  
32-1/4  
10-1/8  
64  
32-1/4  
32-1/4  
10-1/8  
64  
52-3/4  
32-1/4  
10-1/8  
99  
52-3/4  
32-1/4  
10-1/8  
99  
52-3/4  
32-1/4  
10-1/8  
101  
32-1/4  
32-1/4  
10-1/8  
66  
32-1/4  
32-1/4  
10-1/8  
66  
52-3/4  
32-1/4  
10-1/8  
104  
52-3/4  
32-1/4  
10-1/8  
104  
52-3/4  
32-1/4  
10-1/8  
104  
Dimensions  
H
in. 10-1/8  
60  
Weight  
External Finish  
W
Marble White  
57-1/8  
36-5/8  
2-3/8  
Decorative  
in.  
36-5/8  
36-5/8  
2-3/8  
22  
36-5/8  
36-5/8  
2-3/8  
22  
36-5/8  
36-5/8  
2-3/8  
22  
57-1/8  
36-5/8  
2-3/8  
35  
57-1/8  
36-5/8  
2-3/8  
35  
36-5/8  
36-5/8 .  
2-3/8  
22  
36-5/8  
36-5/8  
2-3/8  
22  
57-1/8  
36-5/8  
2-3/8  
35  
57-1/8  
36-5/8  
2-3/8  
35  
57-1/8  
36-5/8  
2-3/8  
35  
Indoor grille Dimensions  
D
H
in.  
in.  
Weight  
OUTDOOR UNIT  
External Finish  
35  
PU12EK PU18EK PU24EK PU30EK PU36EK PU42EK PUH18EK PUH24EK PUH30EK PUH36EK PUH42EK  
Munsell 5Y 7/1  
Sound Pressure Level dB(A)  
Power Supply V, phase, Hz  
50  
53  
55  
55  
55  
56  
230,1, 60  
40  
53  
55  
55  
55  
56  
Max. Fuze Size (time delay) A  
Min. Ampacity  
15  
11  
20  
16  
20  
16  
30  
20  
30  
22  
20  
16  
20  
16  
30  
20  
30  
22  
40  
27  
27  
Fan Motor  
F.L.A.  
0.65  
0.75  
0.65+0.65 0.65+0.65  
0.75+0.75  
0.8 + 0.8  
0.75  
0.65 + 0.65 0.75 + 0.75 0.75+0.75  
0.8 + 0.8  
NH569NXA  
20  
Model (Type)  
RH167NAB RH247NAB NH33NBD NH41NAD NH47NAD NH569NXA RH247NAB  
NH33NBD  
11.5  
NH41NAD  
NH47NAD  
17.5  
Compressor R.L.A.  
L.R.A.  
8.9  
29  
12  
37  
11.5  
54  
14  
73  
17.5  
87  
20  
12  
37  
14  
73  
105  
54  
87  
105  
Crankcase Heater  
Refrigerant Control  
Defrost method  
W
A(W)  
0.12 (28)  
0.12 (28)  
0.17(39)  
0.12 (28)  
0.17(39)  
Capillary Tube  
Reverse Cycle  
38-3/16  
in.  
in.  
34-1/4  
11-5/8  
34-1/4  
11-5/8  
33-1/2  
154  
34-1/4  
11-5/8  
34-1/4  
11-5/8  
38-3/16  
13-9/16  
49-9/16  
220  
38-3/16  
13-9/16  
49-9/16  
260  
34-1/4  
11-5/8  
33-1/2  
131  
34-1/4  
11-5/8  
49-9/16  
202  
38-3/16  
13-9/16  
49-9/16  
246  
38-3/16  
13-9/16  
49-9/16  
268  
Dimensions  
D
H
13-9/16  
in. 25-9/16  
lbs. 105  
49-9/16 49-9/16  
207 208  
49-9/16  
Weight  
245  
REMOTE CONTROLLER  
With indoor unit  
Indoor unit-remote controller: DC 12V, Indoor unit-outdoor unit: DC 12V  
1/2, 3/4 3/8, 5/8  
Control Voltage (by built- in transformer)  
REFRIGERANT PIPING SIZE  
3/8, 5/8  
1/2, 3/4  
1/2, 7/8  
Figures in parentheses include auxiliary booster heat.  
* For 208 volt applications refer to Technical And Service Manual for ratings.  
22  
General Specifications  
Notes: For MS/MSH, MF, MSM  
*1. Rating conditions (cooling)_____ Indoor: 80˚F DB, 67˚F WB Outdoor: 95˚F DB, 75˚F WB  
(heating)_____ Indoor: 70˚F DB, 60˚F WB Outdoor: 47˚F DB, 43˚F WB  
*2. Include auxiliary electric heater operations at 115V. (MSH09EW, MSH12EN, MSH15EN)  
*3. Rated voltage of compressor and fan motor is 115V. (MUM18EW)  
*4. Values are for each indoor unit.  
*5. Depth of outdoor unit ( ) includes thickness of fan grille.  
Operating Range  
Indoor air intake temperature  
Outdoor air intake temperature  
MODEL  
Maximum  
Minimum  
Maximum  
Minimum  
95˚F DB, 71˚F WB  
67˚F DB, 57˚F WB  
80˚F DB, 67˚F WB  
70˚F DB, 60˚F WB  
115˚F DB  
Cooling  
67˚F DB  
75˚F DB, 65˚F WB  
17˚F DB, 15˚F WB  
Heating  
Notes: For PK/PKH, PC/PCH, PL/PLH  
* 1. Rating conditions (cooling)_____ Indoor: 80˚F DB, 67˚F WB Outdoor: 95˚F DB, 75˚F WB  
(heating)_____ Indoor: 70˚F DB, 60˚F WB Outdoor: 47˚F DB, 43˚F WB  
* 2. Rating conditions (heating)_____ Indoor: 70˚F DB, 60˚F WB Outdoor: 17˚F DB, 15˚F WB  
* 3. Heating capacity and power consumption in [ ] include auxiliary electric heater operation at 208/230V.  
Operating Range  
Indoor air intake temperature  
Outdoor air intake temperature  
MODEL  
Maximum  
Minimum  
Maximum  
Minimum  
95˚F DB, 71˚F WB  
67˚F DB, 57˚F WB  
80˚F DB, 67˚F WB  
70˚F DB, 60˚F WB  
115˚F DB  
Cooling  
*5  
0˚F DB  
75˚F DB, 65˚F WB  
17˚F DB, 15˚F WB  
Heating  
*5 With Wind Baffle installed.  
REFRIGERANT TUBING SIZE  
Refrigerant Tubing  
Connection  
Tubing (OD)/N  
MODEL  
Max. Height  
Difference (ft)  
Max. Tubing  
Length (ft)  
Method  
Liquid  
Gas  
3/8  
MS09EW, MSH09EW, MSM18EW  
MF12EN, MF15EN  
25  
25  
49  
65  
1/2  
3/8  
MSM30EN  
MS09EW  
1/4  
(MS09EWX2•MS15ENX1)  
MS15EN  
5/8  
25  
49  
MS12EN, MS15EN, MSH12EN, MSH15EN  
Flared  
PK18EK, PKH18EK, PL18FK, PLH18FK,  
PK12EK, PL12FK  
130  
130  
3/8  
1/2  
5/8  
PK24EK, PKH24EK, PC24EK, PCH24FK,  
PL24FK, PK24EK  
164  
164  
PK30EK, PKH30EK, PL30FK, PLH30FK,  
PC30EK, PCH30EK, PL36FK, PLH36FK,  
PC36EK, PCH36EK, PL42FK2, PC42EK  
3/4  
7/8  
PLH42FK, PCH42EK  
*For more details refer to Technical And Service Manual. All specifications are subject to change without notice.  
MITSUBISHI ELECTRONICS AMERICA, INC.  
HVAC DIVISION  
3100 AVALON RIDGE PL. STE. 200, NORCROSS, GA 30071  
CALL: 770-613-5840 OR 800-433-4822 (PRESS 3) FAX: 800-889-9904  
Form No. MIT-MRS-24-97  

Schumacher Se 8050 User Manual
Sanyo Dc Inverter Split System Xhs1271 User Manual
Samsung Uqt24w6we User Manual
Samsung Aw12ph Series User Manual
Murphy Engine And Generator Controls Keystart 9620 User Manual
Lexmark Genesis S815 User Manual
DELL XPS 8500 User Manual
DELL 1815DN User Manual
BLACK DECKER NLP1800 User Manual
1024md Snowblower User Manual