METROLOGIC INSTRUMENTS, INC.
™
IS1650 FocusE
Area Imaging Bar Code Scanner
Installation and User’s Guide
TABLE OF CONTENTS
Product Overview............................................................................................. 1
Components.................................................................................................. 8
The PowerLink Cable..................................................................................... 11
Cable Installation (Interface Specific)............................................................. 12
Upgrading the Firmware................................................................................. 20
Modes of Operation........................................................................................ 21
Audible Indicators........................................................................................... 22
ii
TABLE OF CONTENTS
Visual Indicators............................................................................................. 23
Daily Maintenance.......................................................................................... 27
Communication Parameters........................................................................... 32
Scanner Pinout Connections.......................................................................... 36
PATENTS...................................................................................................43
LIMITED WARRANTY...................................................................................44
INDEX .......................................................................................................45
iii
INTRODUCTION
PRODUCT OVERVIEW
The IS1650 is a high performance area imaging bar code scanner that utilizes a
high-resolution CMOS imaging sensor for unrivaled image quality. The IS1650 is
the choice of 2D imaging scanners that delivers superior performance for
presentation and fixed-mount applications. The IS1650 employs Omniplanar,
Inc.’s SwiftDecoder™ software, for reliable decoding of all 1D and 2D bar code
symbologies.
Omnidirectional scanning capabilities and an extended depth of field provides
aggressive scanning of all standard 1D, RSS, PDF417, microPDF, Composite,
Matrix and Postal Codes symbology types. In addition, the IS1650 scanner
supports OCR (A, B, & MICR).
The IS1650 provides a built-in object detection sensor (IR) that instantly turns on
the scanner when an object is presented within the scanner’s field of view.
Whether fixed mount or in stand, the IS1650 delivers aggressive, convenient
hands-free scanner. Firmware updates are easily loaded into Flash memory.
KEY PRODUCT FEATURES
The IS1650 is equipped with a multitude of standard features including:
•
•
•
•
•
•
•
•
Automatic Scanning Operation
Supports Multiple Interfaces Including USB and Keyboard Wedge
Custom Edit the Bar Code Data
OPOS and JPOS System Compatible
User Replaceable Cables
Sunrise 2005 Compliant
RoHS Compliant
Supports Customer Software Plug-Ins
1
INTRODUCTION
APPLICATIONS AND PROTOCOLS
The model number on each scanner includes the scanner number and factory
default communications protocol.
SCANNER
COMMUNICATION PROTOCOL(S)
RS232 (TX, RX, RTS, CTS, DTR)
Low Speed USB and RS232 Transmit/Receive
IS1650 -
Keyboard Wedge, Stand-Alone Keyboard and
RS232 Transmit/Receive
IBM 46xx RS485, Full Speed USB, and
RS232 Transmit/Receive
106
The IS1650-47 with a built-in PC Keyboard Wedge Interface is designed for
Keyboard emulation use only. Many RS232 configurable functions are also
available as keyboard wedge functions.
The following are the most important selectable options specific to the keyboard
wedge.
Keyboard Type
•
•
**AT (includes IBM® PS2 models 50, 55, 60, 80)
IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type
•
•
•
•
•
*USA
•
•
•
•
•
Italian
•
•
•
•
Swiss
Swedish/Finnish
Turkish
Belgian
French
German
Hungarian
Japanese
Russian Cyrillic
Slovenian
Spanish
United Kingdom
** For additional information on the IS1650’s default settings refer to
pages 32-35. For information on how to change the default settings, refer to
help files in MetroSet2 or the MetroSelect Single-Line Configuration Guide
(MLPN 00-02544).
2
INTRODUCTION
SCANNER AND ACCESSORIES
BASIC KIT
Part #
Description
IS1650
00-02544
00-02281
Area Imaging Bar Code Scanner
MetroSelect® Single-Line Configuration Guide*
Area Imaging Supplemental Configuration Guide*
IS1650 Series Area Imaging Bar Code Scanner
Installation and User’s Guide*
00-02287
OPTIONAL ACCESSORIES
Part #
Description
AC to DC Power Transformer
Regulated 5.2VDC @ 1 AMP output.
46-00525
46-00526
46-00870
46-00528
46-00529
120V United States
220V-240V Continental European
220V-240V United Kingdom
220V-240V Australia
220V-240V China
Other items may be ordered for the specific protocol being used. To order additional items,
contact the dealer, distributor or call Metrologic’s Customer Service Department at
1-800-ID-METRO or 1-800-436-3876.
3
INTRODUCTION
SCANNER AND ACCESSORIES
OPTIONAL ACCESSORIES
Part #
Description
IS1650 Scanner Interface Specific Cables
RS232 PowerLink Cable with Built in Power Jack,
straight, black
59-59000-3
54-54002-3
54-54020-3
59-59313-N-3
Keyboard Wedge PowerLink Cable with Adapter Cable,
straight, black
Stand Alone Keyboard PowerLink Cable, straight, black
USB Power/Communication Cable, straight, black
Metrologic Voltage Converter (MVC) Cable*
MVC-3M106S-IB9
±12VDC to +5.2VDC, straight, black
* Contact a Metrologic customer service representative for additional
information on the MVC cable series and the host connections available.
Other items may be ordered for the specific protocol being used. To order additional items,
contact the dealer, distributor or call Metrologic’s Customer Service Department at
1-800-ID-METRO or 1-800-436-3876.
4
INTRODUCTION
SCANNER AND ACCESSORIES
OPTIONAL ACCESSORIES
Part #
Description
00-02001
IS1650 Series Stand Installation Guide
46-00710
Flex Stand, Kit
Flex Stand, Kit Components
a. Stand Base...............................................................................Qty. 1
b. Flexible Shaft............................................................................Qty. 1
c. Flexible Shaft Cover ................................................................Qty. 1
d. Scanner Cradle.........................................................................Qty. 1
e. 1/4" – 20 x 1/2" Flat Head Phillips ...........................................Qty. 2
f. #8 Round Head Wood Screw....................................................Qty. 2
Other items may be ordered for the specific protocol being used. To order additional items,
contact the dealer, distributor or call Metrologic’s Customer Service Department at
1-800-ID-METRO or 1-800-436-3876.
5
INTRODUCTION
DESIGN SPECIFICATIONS
IS1650 DESIGN SPECIFICATIONS
OPERATIONAL
Light Source: LED 645 nm
Pulse Duration: 1 ms to 8 ms
Maximum Output
Maximum 85 mA emits 3,120 mlm
of an Osram LED:
0 mm – 254 mm (0" – 10") for
0.330 mm (13 mil) Bar Code at Default Setting
Depth of Scan Field:
49 mm W x 19 mm H (1.9" W x 0.8"H) at 20 mm (0.8")
264 mm x 106 mm (10.4"W x 4.2" H) at 280 mm (11.0")
Field of View:
Minimum Bar Width: 0.127 mm (5.0 mil)
Long Range: 0 mm – 203 mm (0" – 8") from Window
Infrared Activation:
Decode Capability:
Short Range: 0 mm – 101 mm (0" – 4") from Window
Autodiscriminates All Standard 1-D, RSS, PDF417,
microPDF, MaxiCode, Data Matrix, QR Code, UCC, EAN
Composites, Postals, Aztec, *OCR (A, B, MICR)
(Image Transfer) – BMP, TIFF, or JPEG output
* Optional Decode Capability
PC Keyboard Wedge, RS232 (FULL & TTL),
System Interfaces: IBM 46xx RS485, Stand Alone Keyboard,
USB (Low/Full Speed)
Print Contrast: 20% Minimum Reflectance Difference
Up to 80 Data Characters on 1D;
Number Characters Read:
1850 Text Characters for PDF417
Beeper Operation: 7 tones or no beep
Blue Unit Powered, Ready to Scan
White Good Read
Yellow In Stand
Indicators (LED)
Default Settings:
MECHANICAL
Height:
Width:
Depth:
62 mm (2.44")
80 mm (3.15")
116 mm (4.57")
Weight: 204 g (7.2 oz.)
Termination: 10 pin modular RJ45
Specifications are subject to change without notice.
6
INTRODUCTION
DESIGN SPECIFICATIONS (CONT.)
IS1650 DESIGN SPECIFICATIONS
ELECTRICAL
Input Voltage: 5.0VDC ± 0.25V
Peak = 2 W (Typical)
Operating = 1.65 W (Typical)
Power:
Idle / Standby = 800 mW (Typical)
Peak = 400 mA (Typical)
Current:
Operation = 330 mA (Typical)
Idle / Standby = 160 mA (Typical)
DC Transformer: Class 2; 5.2VDC @ 1 AMP
For Regulatory Compliance information, see pages 40- 42
ENVIRONMENTAL
Operating = 0°C to 40° (32° to 104°F)
Temperature:
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 0% to 95% Relative Humidity, Non-Condensing
Light Levels: Up to 100,000 Lux (9,290 Footcandles)
Shock: Designed to withstand 1.0 m (3.3 ft.) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications are subject to change without notice.
7
BASE MODEL CHARACTERISTICS
IS1650 SCANNER
Components
Figure 1. Scanner Components
Item Description
1
2
3
4
5
6
Red Window
Blue LED
White LED
Yellow LED
Trigger
LED Aperture
See Visual Indicators (on page 23)
See Visual Indicators (on page 23)
See Visual Indicators (on page 23)
Initiates Bar Code Read
Speaker
See Audible Indicators (on page 22)
10-pin RJ45, Female Socket,
See Scanner Pinout Connections (on page 36)
7
Cable Connection
8
9
Cable Release
See The PowerLink Cable (on page 11)
M3 Mounting Holes
M3 Mounting Holes for Mounting Scanner
8
BASE MODEL CHARACTERISTICS
IS1650 SCANNER
Dimensions
Figure 2. Scanner Dimensions
Figure 3. M3 Mounting Hole Dimensions
Caution:
The depth of each mounting hole is 12 mm (0.5"). For fixed mount, the mounting
screws should not be over-tightened or go deeper than 10 mm (0.4") passing the
bottom surface of the unit. Going further may cause serious damage to the unit
and void the manufacturer warranty.
9
BASE MODEL CHARACTERISTICS
IS1650 SCANNER
Caution and Serial Number Labels
Each scanner has a label located on the bottom of the unit, as well as text
embedded into the bottom casing. This label provides the unit’s model number,
date of manufacture, serial number, CE and caution information. The following
figure gives an example of the label/text and their location.
Figure 4. Label Samples and Location
Caution:
To maintain compliance with applicable standards, all circuits connected to the
scanner must meet the requirements for SELV (Safety Extra Low Voltage)
according to EN/IEC 60950-1.
To maintain compliance with standard CSA-C22.2 No. 60950-1/UL 60950-1 and
norm EN/IEC 60950-1, the power source should meet applicable performance
requirements for a limited power source.
10
INSTALLATION
THE POWERLINK CABLE
Connecting
Important: If the PowerLink cable is not fully ‘latched’, the unit can
power intermittently.
Figure 5.
Figure 6.
Disconnecting
Before removing the cable from the scanner, Metrologic recommends that the
power on the host system is off and the power supply has been disconnected
from the PowerLink cable.
Figure 7. Releasing the PowerLink Cable
1. Locate the small ‘pin-hole’ on the bottom of the unit near the cable.
2. Bend an ordinary paperclip into the shape shown above.
3. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.
4. There will be a faint ‘click’. Pull gently on the strain-relief of the
PowerLink cable to remove the cable from the unit.
11
INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
RS232 IS1650-14
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of
the PowerLink cable into the 10-pin
socket on the IS1650. There will be
an audible click when the connector
lock engages.
3. Connect the 9-pin D-type connector
of the communication cable to the
proper COM port of the host device.
4. Plug the power supply into the
power jack on the PowerLink cable.
Check the AC input
requirements of the power
supply verify the voltage
matches the AC outlet. The
outlet must be located near the
equipment and be easily
accessible.
5. Connect the power supply
transformer to an appropriate AC
power outlet.
Figure 8.
6. The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light
for approximately two seconds then start to alternately flash. When the
scanner has finished initializing the LEDs will stop flashing and the unit will
beep three times indicating that the scanner is ready for use.
7. Turn on the host device.
Plugging the scanner into a port on the host system does not guarantee
that scanned information will be communicated properly to the host
system. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual.
12
INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
Keyboard Wedge IS1650-47
1. Turn off the host device.
2. Plug the 10-pin RJ45 male end of the
PowerLink cable into 10-pin socket on
the IS1650. There will be an audible
click when the connector lock
engages.
3. Disconnect the keyboard from the
host device.
4. Connect the “Y” ends of the
communication cable to the
keyboard and keyboard port on the
host device.
If necessary, use the male/female
adapter cable supplied with the
scanner for proper connections.
5. Plug the external power supply
(required) into the power jack on the
PowerLink cable.
Check the AC input requirements
of the power supply to verify the
voltage matches the AC outlet.
The outlet must be located near
the equipment and be easily
accessible.
Figure 9.
6. Connect the power supply transformer to an appropriate AC power outlet.
7. The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light
for approximately two seconds then start to alternately flash. When the
scanner has finished initializing the LEDs will stop flashing and the unit will
beep three times indicating that the scanner is ready for use.
8. Turn on the host device.
Plugging the scanner into a port on the host system does not guarantee
that scanned information will be communicated properly to the host
system. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual.
13
INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
Stand Alone Keyboard IS1650-47
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of
the PowerLink cable into the 10-pin
socket on the IS1650. There will be
an audible click when the connector
lock engages.
3. Plug the other end of the
communication cable into the host’s
keyboard port.
4. Plug the external power supply
(required) into the power jack on the
PowerLink cable.
Check the AC input requirements
of the power supply to verify
the voltage matches the AC
outlet. The outlet must be located
near the equipment and be easily
accessible.
5. Connect the power supply
transformer to an appropriate AC
power outlet.
Figure 10.
6. The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light
for approximately two seconds then start to alternately flash. When the
scanner has finished initializing the LEDs will stop flashing and the unit will
beep three times indicating that the scanner is ready for use.
7. Turn on the host device.
Plugging the scanner into a port on the host device does not guarantee
that scanned information will be communicated properly to the host
device. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual.
14
INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
IBM 46xx RS485 IS1650-106
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of
the MVC cable into the 10-pin
socket on the IS1650. There will be
an audible click when the connector
lock engages.
3. Connect the other end of the MVC
cable to the host device.
4. Turn on the host device.
5. The IS1650 will start to initialize.
All LEDs (yellow, white, and blue)
will light for approximately
two seconds then start to
alternately flash. When the scanner
has finished initializing the LEDs
will stop flashing and the unit will
beep three times indicating that the
scanner is ready for use.
Figure 11.
Plugging the scanner into a port on the host system does not guarantee
that scanned information will be communicated properly to the host
system. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual.
15
INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
Integrated USB:
Low Speed IS1650-38
Full Speed IS1650-106
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
USB cable into the 10-pin socket on
the IS1650. There will be an audible
click when the connector lock engages.
3. Plug the USB type A end (locking with
power or non-locking, depending upon
host setup) of the USB cable into the
host’s USB port.
4. Turn on the host device.
5. The IS1650 will start to initialize. All
LEDs (yellow, white, and blue) will light
for approximately two seconds then start
to alternately flash. When the scanner
has finished initializing the LEDs will
stop flashing and the unit will beep
three times indicating that the scanner is
ready for use.
Figure 12.
As a default, the IS1650-38 leaves the factory with USB Keyboard
Emulation Mode enabled.
For information on configuring the IS1650-38 for USB Serial Emulation
Mode, please refer to the USB section of the MetroSelect Single-Line
Configuration Guide (MLPN 00-02544).
Plugging the scanner into a port on the host device does not guarantee
that scanned information will be communicated properly to the host
device. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual.
16
INSTALLATION
FLEX STAND INSTALLATION (OPTIONAL)
Figure 14. Assembling the Stand
18
SCANNER CONFIGURATION
CONFIGURATION MODES
The IS1650 Series scanner has three modes of configuration.
•
•
•
Bar Codes
The IS1650 can be configured by scanning the bar codes included in the
Metrologic Single-Line Configuration Guide (MLPN 00-02544) or the
Supplemental Configuration Guide (MLPN 00-02281). These manuals can be
downloaded FREE of charge from Metrologic’s website
(www.metrologic.com).
MetroSet2
This user-friendly Windows-based configuration program allows you to
simply ‘point-and-click’ at the desired scanner options. This program can be
downloaded FREE of charge from Metrologic’s website
1-800-ID-METRO.
Serial Configuration
This mode of configuration is ideal for OEM applications. This mode gives
the end-user the ability to send a series of commands using the serial port of
the host system. The commands are equivalent to the numerical values of
the bar codes located in the MetroSelect Single-Line Configuration Guide
(MLPN 00-02544).
19
SCANNER CONFIGURATION
The IS1650 FocusE is part of Metrologic's line of scanners with flash
upgradeable firmware. The upgrade process requires a new firmware file
supplied to the customer by a customer service representativeꢀand Metrologic's
MetroSet2 softwareꢀꢀ. A personal computer running Windows 95 or greater with
an available RS232 serial or USB port is also required to complete the upgrade.
PowerLink Cable #54-54014 is required when using RS232 for the
upgrade process. This cable can be ordered from Metrologic at
1-800-ID-METRO. Do not use the standard cable supplied with
keyboard wedge or RS485 scanner interface kits. If using USB for the
upgrade process, the standard USB Type A cable provided with the
scanner can be used.
To upgrade the firmware in the IS1650:
1. Plug the scanner into a serial communication port on the host system.
2. Start the MetroSet2 software.
3. Click on the plus sign (+) next to Industrial Scanners to expand the
supported scanner list.
4. Choose the FocusE from the list.
5. Click on the Configure FocusE Scanner button.
6. Choose Flash Utility from the options list located on the left side of the
screen.
7. Click on the Open File button in the Flash Utility window.
8. Locate and open the flash upgrade file supplied by Metrologic.
9. Select the COM port that the scanner is connected to on the host system.
10. Verify the settings listed in the Flash Utility window.
11. Click on the Flash Scanner button to begin the flash upgrade.
12. A message will appear on the screen when the upgrade is complete.
ꢀ
Metrologic's customer service department can be reached at
1-800-ID-METRO or 1-800-436-3876.
ꢀꢀ
MetroSet2 is available for download, at no additional cost, from
20
SCANNER OPERATION
MODES OF OPERATION*
Presentation Mode, Fixed-Mount or In-Stand (Default)
1. The IR detects an object in the IR activation range and the scanner’s
light output automatically starts to flash as it attempts to scan the bar
code.
2. The scanner continuously attempts to scan the bar code until either it
succeeds or the bar code is removed from the scanner’s field of view.
3. When scanner successfully reads the bar code it will beep once, the
white LED will flash and the decoded data will be transmitted to the
host.
Single Trigger Mode, Out-of-Stand *
The IS1650 can switch into different
modes of operation using the
MetroSet2 Software or Area Imaging
Supplemental Guide (00-02281).
1. The IR detects an object in the IR
activation range and automatically
turns on linear illumination.
2. Aim the scanner’s line of light
over the bar code.
3. Press the trigger to initiate scanning.
The scanner’s light output will start to
flash as it attempts to scan the
bar code.
If the trigger is released the
scanner will stop trying to scan.
4. When scanner successfully reads the
bar code it will beep once, the white
LED will flash and the decoded data
will be transmitted to the host.
Figure 15. Single Trigger Mode,
Out-of-Stand
* For additional configurable modes of operation, please refer to the Area
Imaging Supplemental Configuration Guide (MLPN 00-02281).
21
SCANNER OPERATION
AUDIBLE INDICATORS
When the IS1650 is in operation, it provides audible feedback. These sounds
indicate the status of the scanner. Eight settings are available for the tone of the
beep (normal, 6 alternate tones and no tone). To change the tone, refer to the
MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s
help files.
One Beep
When the scanner successfully reads a bar code, it will beep once and the
white LED will turn on indicating data is being transmitted.
If the scanner does not beep once and the white light does not turn on, then
the bar code has not been successfully read.
Short Razzberry Tone
This tone is a failure indicator (see Failure Modes on page 24).
Long Razzberry Tone
This tone is a failure indicator (see Failure Modes on page 24).
Three Beeps - At Power Up
When IS1650 first receives power, it will start an initialization sequence.
All LEDs (yellow, white, and blue) will light for approximately two seconds then
start to flash alternately. When the scanner has finished initializing the LEDs
will stop flashing and the unit will beep three times indicating that the scanner
is ready for use.
Three Beeps - Configuration Mode
When entering configuration mode, the white LED will flash while the scanner
will simultaneously beep three times. The white and blue LEDs will continue to
flash while in this mode. Upon exiting configuration mode, the scanner will
beep three times, and the LEDs will stop flashing.
When configured, three beeps can also indicate a communications timeout
during normal scanning mode.
When using single-code-configuring, the scanner will beep three times:
a normal tone followed by a short pause, a high tone and then a low tone.
This indicates that the single configuration bar code has successfully
configured the scanner.
22
SCANNER OPERATION
VISUAL INDICATORS
The IS1650 has three LED indicators (yellow, white and
blue) located on the top of the scanner. When the scanner
is on, the flashing or constant activity of the LEDs indicates
the status of the current scan and the scanner.
No LEDs are Illuminated
The LEDs will not illuminate if the scanner is not
receiving power from the host or transformer.
The scanner is in stand-by mode. Present a bar code to
the scanner and the blue LED will turn on when the IR
detects the object.
Figure 16.
Steady Yellow
The yellow LED illuminates when the scanner is in the stand.
Steady Blue
The blue LED illuminates when the scanner is active and linear illumination is
on or when the scanner is attempting to decode a bar code.
Steady Blue and Single White Flash
When the scanner successfully reads a bar code, it will beep once and the
white LED will turn on indicating data is transmitting.
If the scanner does not beep once and the white light does not turn on, then
the bar code has not been read successfully.
Steady White
When the scanner successfully reads a bar code, it will beep once and the
white LED will turn on indicating that data is transmitting.
After a successful scan, the scanner transmits the data to the host
device. Some communication modes require that the host inform the
scanner when data is ready to be received. If the host is not ready to
accept the information, the scanner’s white LED will remain on until the
data can be transmitted.
Alternating Flashing of Blue and White
This indicates the scanner is in configuration mode. A short razzberry tone
indicates that an invalid bar code has been scanned while in this mode.
Flashing Blue
The blue LED will flash if the trigger is pressed while the scanner is in the
in-stand presentation mode. The blue LED will stop flashing after a brief
period of time.
23
SCANNER OPERATION
FAILURE MODES
Long Razzberry Tone – During Power Up
Failed to initialize or configure the scanner. If the scanner does not respond
after reprogramming, return the scanner for repair.
Short Razzberry Tone – During Scanning
An invalid bar code has been scanned when in configuration.
24
SCANNER OPERATION
DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH
MINIMUM BAR CODE ELEMENT WIDTH
1D
PDF
A
B
C
D
.330
13
E
F
G
mm
.132
5.2
.191
7.5
.254
10.4
.533
21
.254
10
.381
15.9
mils
Figure 17. Depth of Field by Minimum Bar Code Element Width
Specifications are subject to change without notice.
25
MAINTENANCE
DAILY MAINTENANCE
Smudges and dirt on the unit's window can interfere with the unit's performance.
If the window requires cleaning, use only a mild glass cleaner containing no
ammonia. When cleaning the window, spray the cleaner onto a lint free, non-
abrasive cleaning cloth then gently wipe the window clean.
If the unit's case requires cleaning, use a mild cleaning agent that does not
contain strong oxidizing chemicals. Strong cleaning agents may discolor or
damage the unit's exterior.
27
TROUBLESHOOTING GUIDE
The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited
warranty terms.
All Interfaces
IS1650 Series Troubleshooting Symptom / Solution Chart
Symptoms
Possible Causes
Solution
No power is being
supplied to the
scanner.
Check transformer, outlet and
power strip. Make sure the cable
is plugged into the scanner.
No LEDs, beep
or illumination
No power is being
supplied to the
Some host systems cannot supply
enough current to power the 1650.
scanner from the host. A power supply may be required.
The wrong
communication cable
has been used.
Check that the communication
cable matches the unit type and
scanner configuration.
There has been a
scanner configuration representative, if the unit will not
failure.
Contact a Metrologic service
Long Razz tone
on power up
hold the saved configuration.
Contact a Metrologic service
representative, if the unit will not
function.
There has been a
diagnostic failure.
Long Razz tone
when exiting
configuration
mode
Re-try to configure the scanner.
Contact a Metrologic service
representative if the unit will not
hold the saved configuration.
There was a failure
saving the new
configuration.
There is a scanning
mechanism failure.
Contact a Metrologic service
representative.
Long Razz tone
Short Razz tone
in configuration
mode
An invalid bar code
has been scanned.
Scan a valid bar code or quit
configuration mode.
28
TROUBLESHOOTING GUIDE
Symptoms
Possible Causes
Solution
The unit powers
up, but does not
beep when bar
code is scanned.
The beeper is
disabled and no tone
is selected.
Enable the beeper and select a
tone.
UPC/EAN, Code 39, interleaved 2
of 5, Code 93, Code 128, Codabar
and PDF are enabled by default.
Verify that the type of bar code
being read has been selected.
The unit powers The bar code
up, but does not symbology trying to
scan and/or
beep.
be scanned is not
enabled.
The unit powers The scanner is trying
Verify that the bar code being
up, but does not to scan a bar code that scanned falls into the configured
scan and/or
beep.
does not match the
configured criteria.
criteria (i.e. character length lock or
minimum bar code length settings).
The following item is only relevant for RS232 and serial emulation USB Interfaces.
The unit scans
The scanner is
configured to support
some form of host
handshaking but is not cable and host are supporting the
receiving the signal.
If the scanner is setup to support
ACK/NAK, RTS/CTS, or
XON/XOFF, verify that the host
a bar code, but
locks up after
the first scan
and the white
LED stays on.
handshaking properly.
The unit scans,
but the data
transmitted to
the host is
Verify that the scanner’s data
format matches that required by
the host. Make sure that the
scanner is connected to the
proper host port.
The scanner’s data
format does not
match the host
system requirements.
incorrect.
29
TROUBLESHOOTING GUIDE
Symptoms
Possible Causes
Solution
The bar code may
have been printed
incorrectly.
Check if it is a check
digit/character/or border problem.
The unit beeps
at some bar
codes and NOT
for others of the
same bar code
symbology.
The scanner is not
configured correctly
for this type of bar
code.
Check if check digits are set
properly.
The minimum symbol
length setting does
not work with the bar
code.
Check if the correct minimum
symbol length is set.
The unit scans
the bar code but
there is no data.
Make sure the scanner is
configured for the appropriate
mode.
The configuration is
not set correctly.
The next four items are only relevant for a Keyboard Wedge interface.
Make sure that the proper PC type
AT, or PS2 is selected. Verify
correct country code and data
formatting are selected. Adjust
inter-character delay symptom.
The configuration is
not set correctly.
The unit scans
but the data is
not correct.
The scanner and host
may not be configured
for the same interface
parameters.
Check that the scanner and the
host are configured for the same
interface parameters.
30
TROUBLESHOOTING GUIDE
Symptoms
Possible Causes
Solution
Increase interscan code delay
setting. Adjust whether the F0
break is transmitted. It may be
necessary to try this in both
settings.
The unit is
transmitting
each character
twice.
The configuration is
not set correctly.
Alpha
characters show
as lower case.
Enable Caps Lock detect setting
of the scanner to detect if the PC
is operating in Caps Lock.
The computer is in
Caps Lock mode.
Everything
These characters
works except for may not be supported Try operating the scanner in Alt
a couple of
characters.
by that country’s key
look up table.
mode.
The following item is only relevant for an RS232 interface.
Check to make sure that the baud
The com port at the
host is not working or
not configured
rate and parity of the scanner and
the communication port match
and the program is looking for
“RS232” data.
The unit powers
up OK and scans
OK but does not
communicate
properly with the
host.
properly.
The cable is not
connected to the
correct com port.
Check to make sure that the cable
is connected to the correct com
port.
Add some inter-character delay to
the transmitted output by using
the Configuration Guides
Inter-character delay
needs to be added to
the transmitted output.
Characters are
being dropped.
(MLPN 00-02544 and 00-02281).
31
DEFAULT SETTINGS
Many functions of the scanner can be “configured” – that is, enabled or disabled.
The scanner is shipped from the factory configured to a set of default conditions.
The default parameter of the scanner has an asterisk (*) in the charts on the
following pages. If an asterisk is not in the default column then the default setting
is OFF or DISABLED. Not every interface supports every parameter. If the
interface supports a parameter listed in the charts on the following pages, a
check mark (ꢁ) will appear.
KBW
IBM 46XX
RS485
PARAMETER
DEFAULT
RS232
USB
&
KEYBOARD
Multi-Try Trigger, Out-of-Stand
Presentation Mode, In-Stand
Presentation Mode, Out-of-Stand
Continuous Trigger
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Single Trigger
Aiming in
Trigger and Continuous Modes
Aiming in Presentation Mode
Long-Range In-Stand
Short-Range In-Stand
Long-Range Out-of-Stand
Short-Range Out-of-Stand
UPC/EAN
Code 128
Code 93
Codabar
Interleaved 2 of 5 (ITF)
MOD 10 check on ITF
Code 11
Code 39
Full ASCII Code 39
PDF
Data Matrix
QR Code
32
DEFAULT SETTINGS
KBW
&
KEYBOARD
IBM 46XX
RS485
PARAMETER
DEFAULT
RS232
USB
Maxicode
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Aztec
Postals
Mod 43 Check on Code 39
MSI-Plessy 10/10 Check Digit
MSI-Plessy Mod 10 Check Digit
Paraf Support ITF
ITF Symbol Lengths
Symbol Length Lock
Beeper tone
Beep/transmit sequence
Communication timeout
Razzberry tone on timeout
Three beeps on timeout
Same symbol rescan timeout:
1000 msecs
ꢁ
ꢁ
Same symbol rescan timeout
configurable in 50 msec steps
(maximum of 6.35 sec.)
No Same symbol timeout
ꢁ
ꢁ
Infinite Same symbol timeout
Inter-character delay
configurable in 1 msec steps
(maximum of 255 msecs)
ꢁ
Number of scan buffers
(maximum)
ꢁ
ꢁ
Transmit UPC-A check digit
Transmit UPC-E check digit
ꢁ
Expand UPC-E
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Convert UPC-A to EAN-13
33
DEFAULT SETTINGS
KBW
&
KEYBOARD
IBM 46XX
RS485
PARAMETER
DEFAULT
RS232
USB
Transmit lead zero on UPC-E
Transmit UPC-A number system
Transmit UPC-A Manufacturer ID#
Transmit UPC-A Item ID#
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Transmit Codabar
Start/Stop Characters
CLSI Editing (Enable)
Transmit Mod 43 Check digit
on Code 39
Transmit Mod 10/ITF
Transmit MSI-Plessy
Parity
Baud Rate
8 Data Bits
7 Data Bits
Stop Bits
Transmit Sanyo ID Characters
Nixdorf ID
LRC Enabled
UPC Prefix
UPC Suffix
Carriage Return
Line Feed-Disabled by
default in KBW
ꢁ
Tab Prefix
Tab Suffix
“DE” Disable Command
Enable Command
DTR Handshaking support
RTS/CTS Handshaking
Character RTS/CTS
Message RTS/CTS
34
DEFAULT SETTINGS
KBW
&
KEYBOARD
IBM 46XX
RS485
PARAMETER
DEFAULT
RS232
USB
XON/XOFF Handshaking
ACK/NAK
Two Digit Supplements
Five Digit Supplements
Bookland
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
977 (2 digit) Supplemental
Requirement
Supplements are not Required
Two Digit Redundancy
Five digit Redundancy
Coupon Code 128
† Configurable Code Lengths
ꢁ
ꢁ
† Code Selects with configurable
Code Length Locks
Configurable Prefix characters
Suffix characters
Prefixes for Individual Code types
Editing
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Function/Control Key Support
Omnidirectional Scanning
Linear Only Scanning
Linear 1D / Omni 2D
ꢁ
ꢁ
† These options are mutually exclusive. One cannot be used in conjunction with the other.
35
SCANNER AND CABLE TERMINATIONS
SCANNER PINOUT CONNECTIONS
The IS1650 scanner interfaces
terminate to a 10-pin, RJ45
Female Socket. The serial
IS1650-14
RS232
Pin
Function
number label indicates the
1
2
3
Ground
interface enabled when the
scanner is shipped from the
factory.
RS232 Transmit Output
RS232 Receive Input
RTS Output
4
5
CTS Input
6
DTR Input
7
Reserved
8
Reserved
9
+5VDC
10
Shield Ground
IS1650-47, Keyboard Wedge &
Stand-Alone Keyboard
Pin
Function
1
2
3
Ground
RS232 Transmit Output
RS232 Receive Input
PC Data
4
5
PC Clock
6
KB Clock
7
PC +5V
8
9
KB Data
+5VDC
Figure 19.
10
Shield Ground
36
SCANNER AND CABLE TERMINATIONS
SCANNER PINOUT CONNECTIONS
IS1650-38
Low Speed USB
Pin
Function
1
2
3
4
5
Ground
RS232 Transmit Output
RS232 Receive Input
RTS Output
CTS Input
6
USB D+
7
V USB
8
USB D-
9
+5VDC
10
Shield Ground
IS1650-106
IBM 46xx RS485 / Full Speed USB
Pin
1
Function
Figure 20.
Ground
2
3
4
RS232 Transmit Output
RS232 Receive Input
IBM A+
5
IBM B-
6
USB D+
7
V USB
8
USB D-
9
+5VDC
10
Shield Ground
37
SCANNER AND CABLE TERMINATIONS
CABLE CONNECTOR CONFIGURATIONS (HOST END)
“Standard” PowerLink
Cable 59-59000-3, Straight
Pin
1
Function
Shield Ground
9
5
2
RS232 Transmit Output
RS232 Receive Input
DTR Input/Light Pen Source
Power/Signal Ground
Reserved
3
4
5
6
6
1
7
CTS Input
9-Pin D-Type Connector
8
RTS Output
9
+5VDC
Stand Alone PowerLink Keyboard
Cable 54-54020-3, Straight
Pin
1
Function
PC Data
NC
2
1
2
4
3
6
5
3
Power Ground
+5VDC PC Power to KB
PC Clock
4
6-Pin Male Mini-DIN Connector
5
6
NC
USB Power/Communication Cable
59-59313-N-3, Straight
Pin
1
Function
PC +5V/V_USB
2
D-
3
D+
4
Ground
USB Non-Locking
Shield Shield
38
SCANNER AND CABLE TERMINATIONS
CABLE CONNECTOR CONFIGURATIONS (HOST END)
Keyboard Wedge
Cable 54-54002-3, Straight
Pin
1
Function
Keyboard Clock
2
4
5
1
3
2
Keyboard Data
No Connect
Power Ground
+5 VDC
3
4
5-Pin DIN, Female
5
Pin
1
Function
PC Data
2
1
2
No Connect
Power Ground
4
3
6
5
3
4
5
6
+5 VDC
PC Clock
No Connect
6-Pin DIN, Male
Metrologic will supply an adapter cable with a 5-pin DIN male connector on one
end and a 6-pin mini DIN female connector on the other. According to the
termination required, connect the appropriate end of the adapter cable to the
PowerLink cable, leaving the necessary termination exposed for connecting to
the keyboard and the keyboard port on the PC.
Keyboard Wedge Adapter Cable
Pin
1
Function
2
PC Clock
PC Data
4
5
2
3
1
3
No Connect
Power Ground
+5 VDC
4
5-Pin DIN, Male
5
Pin
1
Function
Keyboard Data
No Connect
Power Ground
+5 VDC
1
2
2
3
4
5
6
3
4
6-pin Mini DIN, Female
5
Keyboard Clock
No Connect
6
39
REGULATORY COMPLIANCE
Safety
ITE Equipment
IEC 60950-1, EN 60950-1
LED
Class 1 LED Product: IEC 60825-1:1993+A1+A2,
EN 60825-1:1994+A1+A2
Caution
Use of controls or adjustments or performance of procedures other than those specified herein
may result in hazardous radiation exposure. Under no circumstances should the customer
attempt to service the LED scanner. Never attempt to look at the LED beam, even if the
scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the
device. Doing so could result in hazardous radiation exposure. The use of optical instruments
with the LED equipment will increase eye hazard.
Atención
La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los
especificados aquí, pueden provocar una exposición de luz brillante peligrosa. Bajo ninguna
circunstancia el usuario deberá realizar el mantenimiento del LED (Diodo Emisor de Luz) del
lector. Ni intentar mirar al haz del LED incluso cuando este no esté operativo. Tampoco deberá
abrir el lector para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a
la luz del LED. El uso de instrumentos ópticos con el equipo LED puede incrementar el riesgo
para la vista.
Attention
L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de
graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou
la LED. Ne regardez jamais directement le rayon LED, même si vous croyez que le scanner est
inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez
à un risque d’irradiation. L'emploi d'appareils optiques avec cet équipement à LED augmente le
risque d'endommagement de la vision.
Achtung
Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder
Verfahren kann eine gefährliche Licht emittierender Dioden strahlung hervorrufen. Der Kunde
sollte unter keinen Umständen versuchen, den Licht emittierender Dioden-Scanner selbst zu
warten. Sehen Sie niemals in den Licht emittierender Diodenstrahl, selbst wenn Sie glauben,
daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät
hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Licht emittierender
Diodenstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht
das Risiko einer Sehschädigung.
Attenzione
L'utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel
presente Manuale può provocare delle rischiose esposizioni radiattive. Il cliente non deve
assolutamente tentare di riparare egli stesso lo scanner LED (o diodo emettitore di luce). Non
guardate mai il raggio LED (d. emettitore di luce), anche se credete che lo scanner non sia
attivo. Non aprite mai lo scanner per guardare dentro l'apparecchio. Facendolo potete esporVi
ad una radiazione rischiosa. L'uso di apparecchi ottici, equipaggiati con raggi LED (d. emettitori
di luce), aumenta il rischio di danni alla vista.
40
REGULATORY COMPLIANCE
EMC
Emissions
FCC Part 15, ICES-003, CISPR 22, EN 55022
Immunity
CISPR 24, EN 55024
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Class A Devices
The following is applicable when the scanner cable is greater in length than 3 meters
(9.8 feet) when fully extended:
Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres
(9.8 pieds) de long en extension maximale:
Folgendes trifft zu, wenn das Scannerkabel länger als 3 Meter ist:
This equipment has been tested and found to comply with limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at their own expense. Any unauthorized changes or modifications to this
equipment could void the user’s authority to operate this device.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
Notice
This Class A digital apparatus complies with Canadian ICES-003.
Remarque
Cet appareil numérique de classe A est conforme à la norme canadienne NMB-003.
European Standard
Warning
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Funkstöreigenschaften nach EN55022:1998
Warnung!
Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden,
angemessene Massnahmen durchzuführen.
Standard Europeo
Attenzione
Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe
causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure.
Attention
Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la
cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les
mesures adéquates.
41
REGULATORY COMPLIANCE
EMC
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Class B Devices
The following is applicable when the scanner cable is less than 3 meters
(9.8 feet) in length when fully extended:
Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant
pas 3 métres (9.8 pieds) de long en extension maximale:
Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Notice
This Class B digital apparatus complies with Canadian ICES-003.
Remarque
Cet appareil numérique de classe B est conforme à la norme canadienne NMB-003.
42
PATENTS
This METROLOGIC product may be covered by, but not limited to, one or more
of the following U.S. Patents:
U.S. Patent No.:
7,086,595; 7,128,266; 7,213,762; 7,216,810; 7,225,988; 7,225,989;
7,237,722; 7,240,844; 7,240,844; 7,243,847; 7,255,279; 7,267,282;
7,270,272; 7,273,180; 7,278,575; 7,281,661; 7,284,705; 7,293,714;
7,299,986; 7,320,431; 7,325,738
No license right or sublicense is granted, either expressly or by implication,
estoppel, or otherwise, under any METROLOGIC or third party intellectual
property rights (whether or not such third party rights are licensed to
METROLOGIC), including any third party patent listed above, except for an
implied license only for the normal intended use of the specific equipment,
circuits, and devices represented by or contained in the METROLOGIC products
that are physically transferred to the user, and only to the extent of
METROLOGIC’S license rights and subject to any conditions, covenants and
restrictions therein.
Other worldwide patents pending.
43
LIMITED WARRANTY
The IS1650 series scanners are manufactured by Metrologic at its Suzhou, China facility. The IS1650
series scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants
and represents that all IS1650 series scanners are free of all defects in material, workmanship and
design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and
local laws, regulations and ordinances pertaining to their production and labeling.
This warranty is limited to repair, replacement of product or refund of product price at the sole discretion
of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities:
Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate
Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA)
number.
In the event that it is determined the equipment failure is covered under this warranty, Metrologic
shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit
and return such repaired or replaced Product without charge for service or return freight, whether
distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase
price.
This limited warranty does not extend to any Product which, in the sole judgment of Metrologic,
has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage
due to use or misuse produced from integration of the Product into any mechanical, electrical or
computer system. The warranty is void if: (i) the case of Product is opened by anyone other than
Metrologic’s repair department or authorized repair centers; or (ii) any software is installed on the
Product other than a software program approved by Metrologic.
THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES
OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES,
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF
CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE
EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL
METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES,
INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON
BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR
INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT
SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO
METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY
CHANGES TO THE PRODUCT DESCRIBED HEREIN.
CORPORATE HEADQUARTERS,
NORTH AMERICA
METROLOGIC EUROPEAN REPAIR CENTER
(MERC)
Metrologic Instruments, Inc.
90 Coles Rd.
Blackwood, NJ 08012-4683
Customer Service Department
Tel: 1-800-ID-METRO
Fax: 856-228-6673
Metrologic Eria Ibérica, SL
C/Alfonso Gomez, 38-40, 1D
28037 Madrid
Tel: +34 913 751 249
Fax: +34 913 270 437
Email: [email protected]
MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD
Suzhou Sales Office
BLK A, Room# 03/03-04
No.5 Xinghan Street, Xinsu Industrial Square
China-Singapore Suahou Industrial Park, Suzhou, PRC
Tel: 86-512-67622550
Fax: 86-512-67622560
Email: [email protected]
44
INDEX
A
Dimensions ................................... 9
AC .................................3, 7, 12–16
Accessories...................................3
Adapter....................................3, 39
Aperture.........................................8
Audible Indicator..............20, 23–24
E
EMC........................................ 7, 41
EMI ............................................. 41
Emissions.................................... 41
B
F
Bar Code .....................6, 19, 28–31
Bar Code Element.......................25
Beep................6, 20, 23–24, 28–31
Blue LED .......................... See LED
Firmware..................................... 20
Full Speed.........................See USB
H
Host ................................ 11, 12–16
C
I
Cable.........................................4, 5
Connecting...............................11
Disconnecting ..........................11
IBM ..........................................15
Keyboard Wedge.........13, 38–39
MVC.......................................4, 5
PowerLink..3, 11, 12–16, 20, 28–
31, 38–39
Immunity ..................................... 41
Indicator
Audible ................ 6, 8, 20, 23–24
Failure ........................... 8, 23–24
Visual .................. 6, 8, 20, 23–24
Interface............................ 6, 28–31
Cable..................... 12–16, 38–39
IBM...1, 2, 4, 5, 15, 32–35, 36–37
Keyboard Wedge. 1, 2, 3, 13, 32–
35, 36–37
RS232 . 1, 2, 3, 12, 32–35, 36–37
Stand Alone Keyboard 1, 2, 3, 14,
32–35, 36–37
USB..1, 2, 4, 5, 16, 32–35, 36–37
IR ...................................... 1, 21, 26
RS232..........................12, 38–39
Stand Alone Keyboard.14, 38–39
USB .............................16, 38–39
Caution............................12–16, 40
CE ...................................10, 12–16
Class .....................................41, 42
Communication Parameters..32–35
Compliance .........12–16, 40, 41, 44
Configuration.....2, 3, 19, 20, 28–31
Connector Pinouts.................36–37
Converter.....................................16
Current ..........................................7
Customer Service............3, 4, 5, 44
K
Keyboard Country Type................ 2
Keyboard Type.............................. 2
Keyboard Wedge .......See Interface
D
L
DC.....................3, 7, 36–37, 38–39
Decode..........................................6
Default Parameters ...........2, 32–35
IBM ....................................32–35
Keyboard Wedge...............32–35
RS232................................32–35
Stand Alone Keyboard.......32–35
USB ...................................32–35
Depth of Field..............................25
Labels ......................................... 10
Laser........................................... 40
LED........................... 12–16, 28–31
Blue............... 6, 8, 12–16, 23–24
White............. 6, 8, 12–16, 23–24
Yellow............ 6, 8, 12–16, 23–24
Light Levels................................... 7
Light Source.................................. 6
Low Speed........................See USB
45
INDEX
M
Mechanical ................................ 6
Operational................................ 6
Stand ...................... 4, 5, 17–18, 21
Stand Alone KB..........See Interface
Swiftdecoder™............................... 1
Maintenance................................27
Meteor .........................................20
MetroSelect .......................2, 19, 22
MetroSet2..............................20, 21
Mode of Operation.......................21
Mounting......................... See Stand
T
Tone...................................... 23–24
Alternate.................................. 22
Transformer .................. 3, 7, 12–16
Trigger .................................... 8, 21
Troubleshooting .................... 28–31
N
Notices ........................................42
P
Patent..........................................43
PDF.............................................25
Pinouts ......................36–37, 38–39
Power ..........................7, 12–16, 20
Power Supply ..................11, 12–16
PowerLink....................... See Cable
Presentation ................................21
Protocols .......................................2
U
UL ................................... 10, 12–16
Upgrade ...................................... 20
USB
Full Speed .. 1, 2, 4, 5, 16, 32–35,
37, 38
Low Speed . 1, 2, 4, 5, 32–35, 37,
38
R
V
Razz ..........................23–24, 28–31
Repair..........................................44
RMA ............................................44
RS232 ........................See Interface
Ventilation ..................................... 7
Visual Indicator ............... 20, 23–24
Voltage.......................................... 7
W
S
Warranty ..................................... 44
White LED.........................See LED
Window................................... 8, 27
Safety....................................40, 42
SELV.....................................12–16
Service ........................................44
Specifications
Electrical ....................................7
Environmental............................7
Y
Yellow LED .......................See LED
46
March 2008
Printed in the USA
0 0 - 0 2 2 8 7 D
|