™
Classic Rib® Install Guide
The application and detail drawings in this manual are strictly for illustration purposes and may not be appli-
cable to all building designs or product installations. All projects should conform to applicable building codes
for that particular area. It is recommended to follow all building regulations and standard industry practices.
Metal Sales Manufacturing Corporation is not responsible for the performance of the roof system if it is not
installed in accordance with the suggested instructions referenced in this installation manual or in the product
overview. (See Product Manual or Product Technical Literature). If there is a conflict between this manual and
the actual erection drawings, the erection drawings are to take precedence.
Prior to ordering and installing materials, all dimensions should be verified by field measurements.
Metal Sales reserves the right to modify, without notice, any details, recommendations or suggestions. Any
questions you may have regarding proper installation of the roofing system should be directed to your Metal
Sales representative, see pages 2 and 3.
Consult Metal Sales for any additional information not outlined in this manual.
This manual is designed to be utilized as a guide when installing Post Frame and Residential roofing systems.
It is the responsibility of the erector to ensure the safe installation of this product system.
SAFETY
STUDY APPLICABLE OSHA AND OTHER SAFETY REQUIREMENTS BEFORE
FOLLOWING THESE INSTRUCTIONS.
The installation of metal roof systems is a dangerous procedure and should be supervised by trained knowl-
edgeable erectors. USE EXTREME CARE WHILE INSTALLING ROOF PANELS. It is not possible for Metal
Sales to be aware of all the possible job site situations that could cause an unsafe condition to exist. The erec-
tor of the roof system is responsible for reading these instructions and determining the safest way to install the
roof system.
These instructions are provided only as a guide to show a knowledgeable, trained erector the correct part
placement one to another. If following any of the installation steps would endanger a worker, the erector should
stop work and decide upon a corrective action.
Provide required safety railing, netting, or safety lines for crew members working on the roof.
Do not use the roof panel as a walking platform. The roof panels will not withstand the weight of a person
standing at the edge of the panel.
Do not stand on the roof panel until the panels have been attached.
®
CLASSIC RIB
Branch Locations
15.) FONTANA BRANCH
14213 Whittram Avenue
Fontana, CA 92335
909.829.8618 Phone
800.782.7953 Toll Free
909.829.9083 Fax
1.) DENVER BRANCH
7990 E. I-25 Frontage Road
Longmont, CO 80504
303.702.5440 Phone
800.289.7663 Toll Free
800.289.1617 Toll Free Fax
8.) SPOKANE BRANCH
East 2727 Trent Avenue
Spokane, WA 99202
509.536.6000 Phone
800.572.6565 Toll Free
509.534.4427 Fax
16.) ANCHORAGE BRANCH
4637 Old Seward Highway
Anchorage, AK 99503
907.646.7663 Phone
866.640.7663 Toll Free
907.646.7664 Fax
2.) JACKSONVILLE BRANCH
7110 Stuart Avenue
Jacksonville, FL 32254
904.783.3660 Phone
800.394.4419 Toll Free
904.783.9175 Fax
800.413.3292 Toll Free Fax
9.) SEATTLE BRANCH
20213 84th Avenue, South
Kent, WA 98032
253.872.5750 Phone
800.431.3470 Toll Free (Outside WA)
800.742.7900 Toll Free (Inside WA)
253.872.2008 Fax
17.) BAY CITY BRANCH
5209 Mackinaw Road
Bay City, MI 48706
989.686.5879 Phone
888.777.7640 Toll Free
989.686.5870 Fax
3.) JEFFERSON BRANCH
352 East Erie Street
Jefferson, OH 44047
440.319.3779 Phone
800.321.5833 Toll Free
440.576.9242 Fax
10.) NEW ALBANY BRANCH
999 Park Place
New Albany, IN 47150
812.944.2733 Phone
812.944.1418 Fax
888.777.0112 Toll Free Fax
18.) DETROIT LAKES BRANCH
1435 Egret Avenue
Detroit Lakes, MN 56501
218.847.2988 Phone
888.594.1394 Toll Free
218.847.4835 Fax
888.594.1454 Toll Free Fax
800.233.5719 Toll Free Fax
11.) ROCK ISLAND BRANCH
8111 West 29th Street
Rock Island, IL 61201
309.787.1200 Phone
800.747.1206 Toll Free
309.787.1833 Fax
4.) INDEPENDENCE BRANCH
1306 South Powell Road
Independence, MO 64057
816.796.0900 Phone
800.747.0012 Toll Free
816.796.0906 Fax
12.) DEER LAKE BRANCH
29 Pinedale Industrial Road
Orwigsburg, PA 17961
570.366.2020 Phone
800.544.2577 Toll Free
570.366.1648 Fax
19.) MOCKSVILLE BRANCH
188 Quality Drive
Mocksville, NC 27028
704.859.0550 Phone
800.228.6119 Toll Free
704.859.0157 Fax
5.) SELLERSBURG BRANCH
7800 State Road 60
Sellersburg, IN 47172
812.246.1866 Phone
800.999.7777 Toll Free
812.246.0893 Fax
800.477.9318 Toll Free Fax
800.228.7916 Toll Free Fax
800.544.2574 Toll Free Fax
20.) FORT SMITH BRANCH
7510 Ball Road
Fort Smith, AR 72908
479.646.1176 Phone
877.452.3915 Toll Free
479.646.5204 Fax
13.) TEMPLE BRANCH
3838 North General Bruce Drive
Temple, TX 76501
254.791.6650 Phone
800.543.4415 Toll Free
254.791.6655 Fax
6.) ROGERS BRANCH
22651 Industrial Boulevard
Rogers, MN 55374
763.428.8080 Phone
800.328.9316 Toll Free
763.428.8525 Fax
800.543.4473 Toll Free Fax
21.) SIOUX FALLS BRANCH
2700 West 3rd Street, Suite 4
Sioux Falls, SD 57104
605.335.2745 Phone
888.299.0024 Toll Free
800.938.9119 Toll Free Fax
14.) WOODLAND BRANCH
1326 Paddock Place
Woodland, CA 95776
530.668.5690 Phone
800.759.6019 Toll Free
530.668.0901 Fax
7.) NASHVILLE BRANCH
4314 Hurricane Creek Boulevard
Antioch, TN 37013
615.229.6570 Phone
800.251.8508 Toll Free
615.283.4283 Fax
TECHNICAL SUPPORT
TECHNICAL SERVICES
545 South 3rd Street, Suite 200
Louisville, KY 40202
800.419.4372 Toll Free Fax
502.855.4300 Phone
800.406.7387 Toll Free
502.855.4290 Fax
800.944.6884 Toll Free Fax
3
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
TABLE OF CONTENTS
CLASSIC RIB
PAGE NO.
General Information
Important Information ................................................................................1
Metal Sales' Locations ..............................................................................2
Customer Service .....................................................................................3
Panel Information
Panel Overview .........................................................................................6
Testing and Approvals ...............................................................................6
Fastening Patterns ....................................................................................6
Panel Lap Detail .......................................................................................7
Section Properties ....................................................................................7
Classic Rib Fastener Installation.......................................................................8
Post Frame Flashing Profiles .......................................................................9-11
Residential Flashing Profiles ..........................................................................12
Accessory Profiles ...........................................................................................13
Handling Material
Receiving Material ..................................................................................14
General Handling ....................................................................................14
Mechanical Handling ..............................................................................14
Manual Handling .....................................................................................15
Storage
General ...................................................................................................16
Foot Traffic .............................................................................................16
Required Tools.........................................................................................16
Design / Installation Considerations
General....................................................................................................17
Condition of Substructure ........................................................................17
Field Cutting and Touch-Up
Field Cutting.............................................................................................18
Touch-Up Paint ........................................................................................18
Ventilation ................................................................................................18
Fastener Selection Guide ................................................................................19
Installation Overview ........................................................................................20
Post Frame Panel Installation
Installing Inside Closures (Step 1)...........................................................21
Installing First Panel (Step 2)...................................................................21
Installing Endlap Panel (Step 3) ..............................................................22
Installing Sidelap Panel (Step 4)..............................................................22
14" Universal Ridge Detail.......................................................................23
Low Profile Ridge Vent ............................................................................23
Outside Corner Detail ..............................................................................23
Inside Corner Detail.................................................................................23
Gable Trim Detail.....................................................................................24
Rake Trim Detail ......................................................................................24
Universal Sidewall Detail .........................................................................24
Universal Endwall Detail..........................................................................24
Eave Molding Detail.................................................................................25
Universal Gambrel Detail.........................................................................25
4
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
TABLE OF CONTENTS (cont.)
CLASSIC RIB
PAGE NO.
Angle Base Detail ....................................................................................25
Double Angle Detail .................................................................................25
Drip Cap Detail ........................................................................................26
Base Molding Detail.................................................................................26
Cannonball Track Cover Detail................................................................26
National Track Cover Detail.....................................................................26
Door Jamb Molding Detail .......................................................................27
Mini-Angle - U-Flashing Detail.................................................................27
Post Trim Detail .......................................................................................27
Door Post Trim Detail...............................................................................27
Overhead Door Trim Detail......................................................................28
Soffit Detail ..............................................................................................28
12" Soffit Detail ........................................................................................28
24" Soffit Detail ........................................................................................28
Installation Overview ........................................................................................29
Residential Panel Installation
Installing Inside Closures (Step 1)...........................................................30
Installing First Panel (Step 2)...................................................................30
Installing Second Panel (Step 3) .............................................................31
Installing Second Eave Panel (Step 4) ....................................................31
14" Universal Ridge Detail.......................................................................32
Ridge / Hip Cover Detail ..........................................................................32
Vented Ridge Detail.................................................................................32
Gable Trim Detail.....................................................................................32
Eave Detail ..............................................................................................33
Gutter Detail.............................................................................................33
Valley Detail.............................................................................................33
Pitch Break Detail ....................................................................................33
Chimney / Cricket Detail ..........................................................................34
Roof Penetration Detail............................................................................34
Care and Maintenance .....................................................................................35
5
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
PANEL INFORMATION
CLASSIC RIB
Anti-Siphon Groove
1 3/4"
3/4"
3/8"
C
5/8"
9"
2 3/4"
3 1/8"
36" Coverage
PANEL OVERVIEW
Finishes: MS Colorfast45® and Acrylic Coated Galvalume®
Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume®
AZ50 per ASTM A 792 for painted Galvalume®
G60, G90 or G100 per ASTM A 653 for Galvanized
Gauges: 29 ga and 26 ga standard; 24 ga optional
36" panel coverage, 3/4" rib height
Panel Length: Minimum: 5'; Maximum: 45' recommended
Exposed fastened, low profile roof and wall system
Bell-top trapezoidal rib on 9" centers
Minimum roof slope: 3:12
TESTING AND APPROVALS
UL 2218 Impact Resistance - Class 4
UL 790 Fire Resistance Rating - Class A, per building code
UL 263 Fire Resistance Rating - per assembly
UL 580 Uplift Resistance - Class 90 Constructions: #560, 584
ASTM E 455, Diaphragm Capacity
Texas Wind Storm - Evaluation RC-161
2010 FBC Approvals - FL9482.2, FL9482.3, FL10999.3, FL10999.4, FL14645.7, FL14645.8,
FL14645.9 and FL15478.2
Miami-Dade County, Florida NOA 11-0617.02
Miami-Dade County, Florida NOA 10-0427.04 - Roof
FASTENING PATTERNS
End of Panel
Field of Panel
6
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
PANEL INFORMATION
PANEL LAP DETAIL
1/4"-14 x 7/8" Stitch Screw
(for roof only)
Classic Rib Panel
#9-15 Woodscrew
Anti-Siphon Groove
SECTION PROPERTIES
ALLOWABLE UNIFORM LIVE LOADS, psf
For various fastener spacings
SECTION PROPERTIES
Inward
Load
Outward
Load
Top in Compression
Bottom in Compression
Width Yield Weight
Ga
Ixx
Sxx
Ixx
Sxx
in
ksi
psf
in4/ft
in3/ft
in4/ft
in3/ft
1.5’ 2’
2.5’ 3’
3.5’
27
4’ 1.5’
2’
2.5’ 3’
3.5’ 4’
29
26
24
36
36
36
80
80
50
0.62
0.79
1.03
0.0100
0.0127
0.0163
0.0151
0.0192
0.0249
0.0053
0.0070
0.0103
0.0118
0.0153
0.0208
142 81
52
36
47
53
21 179 103 66
27 227 131 84
30 245 141 91
46
59
64
34
44
47
26
33
36
185 105 68
208 119 77
35
39
1. Theoretical section properties have been calculated per AISI 2007 'North American Specification for the Design of Cold-Formed Steel
Structural Members'. Ixx and Sxx are effective section properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2007 specifications considering bending, shear, combined bending and shear and
deflection. Allowable load considers the 3 or more equal spans condition. Allowable load does not address web crippling, fasteners,
support material or load testing. Panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase for wind.
5. Diaphragm Capacity - 296 plf average Ultimate Shear Strength using the above fastening pattern on 2x supports located 2' on center,
per ASTM E 445.
7
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
FASTENER INSTALLATION
USING SCREWS:
For fastening with screws, it is best to use a painted or plated screw, Type A or driller tip with a flat rubber washer. The
correct screw gun is also important to the proper installation of self-drilling or self-tapping screws. A tool with the appropriate
speed and torque setting (as recommended by the fastener manufacturer) will help prevent fastener thread strip-out and
possible damage to the panel or its coating. Typically 40 screws should be used per square for 2' wide panels and 80 screws
should be used per square for 3' wide panels.
TOO LOOSE
Sealing material is not
visible; not enough
compression to seal.
TOO TIGHT
CORRECT
Washer is deformed;
sealing material pressed
beyond fastener edge.
Sealing material slightly
visible at edge of washer.
Assembly is water tight.
SCREW ATTACHMENT
SEATING THE WASHER - Apply sufficient torque to seat the washer - do not overdrive the fastener.
TO PREVENT WOBBLING - Make sure fastener head is completely engaged in the socket. If the head does not go all
the way in the socket - tap the magnet deeper into the socket to allow full head engagement. Metal chips will build
up from drilling and should be removed from time to time.
PROTECT DRILL POINT - Push only hard enough on the screw gun to engage clutch. This prevents excess friction and
burn out of the drill point. Correct pressure will allow screw to drill and tap without binding.
8
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB POST FRAME FLASHING PROFILES
3
20
5
6
11
12
10
4
14
23
21
17
15
16
22
7
9
8
18
2
13
1
1 - BASE MOLDING
1 - ANGLE BASE
2 - J-CHANNEL
C
C
1"
1"
11/2"
7/8"
45°
2"
1"
1"
11/2"
C
7/8"
1"
4 - SOFFIT
4 - 12" SOFFIT
3 - 14" UNIVERSAL RIDGE
13/4"
C
51/2"
3/8"
4"
51/2"
13/4"
51/8"
12"
3/8"
143°
31/2"
1/2"
C
C
12"
4 - 24" SOFFIT
5 - UNIVERSAL ENDWALL
6 - UNIVERSAL SIDEWALL
C
C
143°
4"
5"
1"
3/4"
51/8"
51/2"
31/2"
13/4"
31/2"
7/8"
1/2"
C
24"
1"
9
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB POST FRAME FLASHING PROFILES
7 - MINI ANGLE
8 - INSIDE CORNER
9 - POST TRIM
C
C
11/2"
11/2"
4"
C
1"
91/4"
11/2"
4"
10 - TOP MOUNT TRACK
COVER
10 - CANNONBALL TRACK
COVER
10 - NATIONAL TRACK COVER
111/16"
C
31/2"
13/8"
C
13/4"
35/8"
C
17/8"
41/2"
147°
67/8"
21/2"
21/4"
147°
13/8"
5/8"
15/16"
1/2"
3/4"
11 - GABLE TRIM
12 - RAKE TRIM
13 - OUTSIDE CORNER
23/8"
4"
4"
C
5/8"
C
1"
11/16"
C
51/4"
4"
23/4"
1/2"
5/8"
5/8"
3/8"
14 - OVERHEAD DOOR TRIM
15 - DOOR JAMB
16 - DRIP CAP
C
11/2"
17/8"
7/8"
15/8"
21/2"
17/8"
7/8"
3/4"
1/2"
C
91/4" or 71/4"
C
77/8"
10
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB POST FRAME FLASHING PROFILES
17 - DOOR POST TRIM
18 - FRAMING CLOSURE
20 - TRANSLUCENT PANEL
C
11/4"
55/8"
31/4"
2"
11/2"
35/8"
C
3/4"
LENGTHS: 8'-0",10'-0",12'-0"
21 - EAVE MOLDING
22 - DOUBLE ANGLE
23 - WIDE Z-METAL
31/2"
C
C
11/4"
7/8"
105°
C
11/8"
41/8"
11/2"
23/4"
5/8"
130°
3/4"
13/16"
1/4"
24 - UNIVERSAL GAMBREL
25 - RAKE / EAVE TRIM
26 - 3/8" F & J-CHANNEL
11/4"
15/8"
31/2"
C
3/8"
41/4"
1"
120°
23/4"
23/4"
1/2"
1/4"
C
3/8" Hem
26 - 3/4" F & J-CHANNEL
11/4"
3/4"
1"
21/4"
C
11
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB RESIDENTIAL FLASHING PROFILES
1
6
5
4
2
1
3
1 - RIDGE / HIP COVER
1 - 13" STEP RIDGE / HIP
COVER
2 - GABLE TRIM
4"
C
5/8"
51/2"
10"
C
C
11/16"
11/2"
51/4"
1"
5/8"
3 - EAVE
4 - UNIVERSAL ENDWALL
4 - PITCH BREAK
37/8"
C
4"
Specify Angle
4"
1"
C
3"
31/2"
C
7/8"
6"
5/8"
5 - UNIVERSAL SIDEWALL
6 - VALLEY
C
C
1"
4"
31/2"
91/2"
7/8"
1"
12
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB ACCESSORY PROFILES
UNIVERSAL CLOSURE
CLASSIC RIB CLOSURES
VERSA VENT
OUTSIDE
INSIDE
1" x 1 1/2" x 50'-0"
1" x 1 1/2" x 10'-0"
1" x 3'-0"
POLYETHYLENE FOAM
TAPE SEALANT
TUBE SEALANT
TOUCH-UP PAINT
3
3
8
32
/ " X / " X 50'
SINGLE BEAD
BUTYL - GRAY
10.3 oz. CARTRIDGE
URETHANE
AVAILABLE IN PINTS
PVDF / MS Colorfast45
RUBBER ROOF JACK
MS-HT UNDERLAYMENT
1
1
4
8
MINI ( / " TO 1 / " O.D. PIPE)
3
4
#2 (1 / " TO 3" O.D. PIPE)
#4 (3" TO 6" O.D. PIPE)
#6 (6" TO 9" O.D. PIPE)
#8 (7" TO 13" O.D. PIPE)
13
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB HANDLING MATERIAL
RECEIVING MATERIAL
It is the responsibility of the installer to unload material from the delivery truck. The installer shall be responsible for
providing suitable equipment for unloading of material from the delivery.
After receiving material, check the condition of the material, and review the shipment against the shipping list to ensure all
materials are accounted for. If damages or shortages are discovered, it should be noted on the Bill of Lading at the time of
delivery. A claim should be made against the carrier as soon as possible. Metal Sales is not responsible for any damages or
shortages unless they are documented in writing and presented to Metal Sales within 48 hours.
GENERAL HANDLING
Each bundle should be handled carefully to avoid being damaged. Care should be taken to prevent bending of the
panel or abrasion to finish. Whenever possible, the bundle should remain crated until it is located in its place of stor-
age. If bundles must be opened, we recommend you re-crate them before lifting. To avoid damage please lift the
bundle at its center of gravity.
CAUTION
Improper loading and unloading of bundles and crates may result in bodily harm and/or
material damage. Metal Sales is not responsible for bodily injuries and/or material
damages resulting from improper loading and unloading.
MECHANICAL HANDLING
Forklift - A forklift may be used for panels up to 20'-0" long. Please make sure the forks are at their maximum separation.
Do not transport open bundles. When transporting bundles across rough terrain, or over a longer distance, some means of
supporting the panel load must be used.
Crane - A crane should be used when lifting panels with lengths greater than 20'-0". Please be sure to utilize a spreader bar to
ensure the even distribution of the weight to the pick up points. As a rule when lifting panels, no more than 1/3 of the length of
the panel should be left unsupported. Never use wire rope because this will damage the panels.
14
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
HANDLING MATERIAL (cont.)
MANUAL HANDLING
When handling painted steel, care should be taken to prevent scratching of material. Clean gloves should be worn at all times
to prevent a reaction with salts found on bare skin. Installers should wear rubber sole shoes to keep from scuffing material
while walking on the roof.
Handling of individual panels should be done carefully and properly to avoid bending or damaging. Panels should be carried
by grasping the edge of the panel so that the panel is vertical to the ground. The panel should not be carried horizontal to the
ground as this could cause the panel to buckle or bend in the center.
Normally, individual panels can be handled by people placed every 6'-0" to 8'-0" along the length of the panel.
INCORRECT
15
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB STORAGE
GENERAL
Please inspect panels for moisture accumulation. If moisture has formed, the panels should be unbundled, wiped dry, and
allowed to dry completely. Once dry, carefully re-stack the panels and loosely recover allowing for ample air circulation.
Bundled sheets should be stored high enough off of the ground to allow for air circulation and prevent contact with
accumulating water. Elevate one end of the bundle to allow any moisture to run off the panels. Metal Sales recommends
covering the bundle with a tarpaulin. Do not use tight fitting plastic-type tarpaulins as panel bundle covers. While they may
provide protection from heavy downpours, they can also retard necessary ventilation and trap heat and moisture that may
accelerate metal corrosion. If panels are to be stored in possible bad weather, we suggest they be stored inside. Extended
storage of panels in a bundle is not recommended. Under no circumstances should the panels be stored near or come in
contact with salt water, corrosive chemicals, ash, or fumes generated or released inside the building or nearby plants,
foundries, plating works, kilns, fertilizer, and wet or green lumber.
TARPAULIN
TARPAULIN
PANEL COVER
SHEET
PANEL COVER
SHEET
PANELS
ELEVATE END OF BUNDLE
FOOT TRAFFIC
Care of metal panels and flashings must be exercised throughout erection. Foot traffic can cause distortion of panel and
damage to finish. Traffic over the installed system must be kept to an absolute minimum. Installers should wear rubber
sole shoes to keep from scuffing material while walking on the roof.
When walking on the roof panels is unavoidable, walk only in the flats of the panel. Walking on the ribs can cause
damage to the panels.
REQUIRED TOOLS
Standard required tools for field installation include:
• Screw Guns
• Safety Goggles
• Gloves
• Ear Plugs
• Magnetic Bits
• Metal Nibbler or Shear
• Tin Snips
• Fall Protection
• Tape Measure
• Hammer
• Chalk Line
• Drill with bits
• Pop Rivet Gun
16
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
DESIGN / INSTALLATION CONSIDERATIONS
GENERAL
Metal Sales’ panels are designed to be installed over open framing and/or directly over a wood substrate (minimum 5/8”)
with 30# felt moisture barrier (or an Ice and Water Shield when required by Local Building Codes).
Always check with local building codes prior to all installations for any additional requirements that may be specific to your
area.
Galvanized and Galvalume panels should not be in contact with, or subject to, water runoff from copper, lead, or uncoated
steel materials.
Condensate water from air conditioning units typically contains dissolved copper. This condensate should be discharged
through a plastic pipe extended beyond the edge of the roof.
CONDITION OF SUBSTRUCTURE
The roof should be inspected for any trapped moisture or structural damage such as bowing or sagging rafters and warped or
loose roof purlins or solid decking. These areas should be repaired prior to installing new metal panels.
Prior to installation, make sure there are no nails or fasteners protruding from the roof framing or wood substrate which could
damage the panels and impede the installation process.
When installed, panel distortion may occur if not applied over properly aligned and uniform substructure.
Whether installing over new or existing roof, the installer should check the roof deck for squareness before installing panels.
Several methods can be used to verify squareness of the structure for proper installation of the panels.
METHOD “A” - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from
similar points at the ridge and eave and obtain the same dimension.
METHOD “B” - The 3-4-5 triangle system may also be used. To use this system, measure a point from the corner along the
edge of the roof at a module of three (3). Measure a point from the same corner along another edge at a module of four (4).
By measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a
square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made
square, the roof system cannot be installed as shown in these instructions.
METHOD A
10
METHOD B
4
5
10
3
17
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB FIELD CUTTING AND TOUCH-UP
FIELD CUTTING
Tin snips or a "nibbler" type electric tool are recommended for field cutting metal panels. Cutting the steel generates slivers
or metal chips. These slivers and metal chips must be immediately removed from the panels because they will damage the
finish and shorten the life of the product.
One method of preventing this problem is to flip the panels over when cutting. This allows the slivers and metal chips to be
brushed from the back side and avoids damaging the paint on the top side of the panels.
When cutting metal panels and flashings, goggles must be worn for eye protection.
CAUTION
All product surfaces should be free of debris at all times. Installed surfaces should be
wiped clean at the end of each work period. Never cut panels over metal surfaces.
Metal shavings will rust on the surface, voiding the warranty.
TOUCH-UP PAINT
All painted panels and flashings have a factory applied baked on finish. Handling and installing panels may result in some
small scratches or nicks to the paint finish. Touch-up paint is available in matching colors from Metal Sales. It is recom-
mended that a small brush be used to apply touch-up paint to those areas that are in need of repair. Touch-up paint does not
have the superior chalk and fade resistance of the factory applied paint finish and will normally discolor at an accelerated
rate. Aerosol paint should not be used because of the overspray that may occur.
SPRAY PAINT
TOUCH-UP PAINT
VENTILATION
Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the result-
ing problems of moisture damage and loss of insulation efficiency.
Condensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point of
the air. This phenomenon creates problems that are not unique with metal buildings; these problems are common to all types
of construction.
The underside of the metal roof on a typical metal building (no attic) should be protected from condensation by insulating
with a faced insulation. This should reduce the potential of condensation forming on the underside of the panels.
On buildings that have an attic space or are being retrofitted with a metal roofing system, vents should be placed at both the
eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space.
VENT
VENT
ATTIC
INSULATION
WALL VENTS
VENT AT
OR OPENINGS
EAVE
BUILDING
BUILDING
WITH ATTIC
WITHOUT ATTIC
18
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB FASTENER SELECTION GUIDE
SIZE
TYPE
FINISH
APPLICATION
POP RIVET
1
3
8
16
/ " x / "
A
Unpainted
Flashing to Panel,
Flashing to Flashing
1
3
8
16
/ " x / "
A
Painted
Flashing to Panel,
Flashing to Flashing
SIZE
TYPE
FINISH
APPLICATION
PANCAKE HEAD WOODSCREW
#10-12 x 1"
A
Plated
Panel or Flashing to
wood substructure
SIZE
TYPE
FINISH
APPLICATION
WOODSCREW
STITCH SCREW
#9-15 x 1"
#9-15 x 1 / "
#9-15 x 2"
A
A
A
Painted
Painted
Painted
Panel or Flashing
to wood substructure
1
2
SIZE
TYPE
FINISH
APPLICATION
1
7
4
8
# / - 14 x / "
Stitch
Painted
Flashing to Panel,
Flashing to Flashing,
Panel Sidelap
PANEL
Length - Minimum factory cut length is 5'-0" on panels. Panels over 45'-0" require additional consideration in packaging,
shipping, and erection. Please consult Metal Sales for recommendations.
There are two critical measurements involving metal panels: the length of panel overhang required at the eave, and the peak
end. In each case a certain measurement is required. Check each measurement to ensure panel placement gives you the dis-
tance required at the eave, and peak condition. In most cases any variance can be taken out at the eave or peak ends.
19
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
INSTALLATION OVERVIEW
INSTALLATION OVERVIEW
As shown below with the number designations, install panel against the prevailing wind. Installing Wall Panels first then
Roof Panels
To minimize corrosion, siding panels should not be installed all the way to the ground.
Siding panels should lap over the foundations or splash boards at least three inches.
Make sure panels are square and plumb, to assure straight and proper alignment of the entire row of panels.
For areas with high wind considerations, closer fastener spacing may be required.
It is necessary to attach a temporary guide to the foundation to use as an alignment guide when installing siding panels.
Siphon groove side of panel must be overlapped with the non siphon groove side of the adjacent panel (if applicable) .
Prevailing
Winds
RIDGE DETAIL
(SEE PAGE 30)
PANEL ENDLAP
(SEE PAGE 29)
GABLE DETAIL
(SEE PAGE 31)
4
2
5
3
1
EAVE DETAIL
(SEE PAGE 32)
3
J-CHANNEL
(SEE PAGE 34)
2
1
CORNER DETAIL
(SEE PAGE 30)
ANGLE BASE DETAIL
(SEE PAGE 32)
20
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB POST FRAME PANEL INSTALLATION
NOTE:
-Eave Molding, Gutter and Valley Flashings must first be installed before panel installation can begin.
-Panels can be installed going from either left to right or right to left / looking from eave to peak.
INSTALLING INSIDE CLOSURES
1. Apply a row of Tape Sealant across the top leg of the Eave Molding along the width of the
building.
STEP
1
2. Align and place Inside Closures over the Tape Sealant. It is critical that Inside Closures are
square to building as this will control the alignment of the panels. (See page 24 to check
building square).
3. Apply a row of Tape Sealant across the top of the Inside Closure (not shown for clarity).
TAPE SEALANT
INSIDE CLOSURE
INSTALLING FIRST PANEL
1. Install the first panel over the Inside Closure allowing desired overhang. Make sure the panel is
square to the eave and rake.
STEP
2
2. Fasten through panel, closure, and sealants into decking with appropriate amount of fasteners to
meet local building code. (see fastening pattern on page 6). Fasteners must penetrate closure and
sealant.
3. After securing panel at eave, repeat the fastening pattern at all panel support locations.
FASTENER
ROOF PANEL
INSIDE CLOSURE
w/ TAPE SEALANT
21
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB POST FRAME PANEL INSTALLATION
INSTALLING ENDLAP PANEL (IF REQUIRED)
1. Apply a row of Tape Sealant across and over the ribs of the eave panel about 3" from panel end.
2. Install the ridge panel over the eave panel and Tape Sealant with a 6" Endlap. Fasten through both
panels and Tape Sealant into support with appropriate amount of fasteners to meet local building
code. (See fastening pattern on page 6). Fasteners must penetrate sealant.
STEP
3. After securing panel, repeat the fastening pattern at all panel support locations.
3
RIDGE PANEL
FASTENER
EAVE PANEL
TAPE SEALANT
6"
LAP
INSTALLING SIDELAP PANEL
1. Place the lapping seam of the second panel on top of previously installed panel so that panel ends
are flush at eave (See below).
2. Fasten through panel, closure, and Tape Sealant into support with appropriate amount of
fasteners to meet local building code. (See fastening pattern on page 6). Fasteners must penetrate
closure and sealant.
STEP
4
3. After securing panel, repeat the fastening pattern at all panel support locations.
FASTENER
INSIDE CLOSURE
SYPHON
STITCH SCREW
GROOVE*
*PANELS WITHOUT A SYPHON
GROOVE REQUIRE TAPE
SEALANT IN THE SIDELAP
FIRST PANEL INSTALLED
22
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB POST FRAME BUILDING DETAILS
14" UNIVERSAL RIDGE DETAIL
LOW PROFILE RIDGE VENT DETAIL
ROOF PANEL
STITCH SCREW
(EVERY RIB*)
OUTSIDE CLOSURE
TAPE SEALANT
FASTENER
14" OR 20" UNIVERSAL
RIDGE CAP
RIDGE VENT
RIDGE / HIP COVER
FASTENER
(EVERY RIB*)
* FASTENER SPACING TO BE 8" - 12" O.C.
OUTSIDE CORNER DETAIL
* FASTENER SPACING TO BE 8" - 12" O.C.
INSIDE CORNER DETAIL
WALL PANEL
TAPE SEALANT
FASTENER
STITCH SCREW
(1'-0" O.C.)
TAPE SEALANT
FASTENER
STITCH SCREW
(1'-0" O.C.)
OUTSIDE CORNER
INSIDE CORNER
WALL PANEL
23
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
POST FRAME BUILDING DETAILS
GABLE TRIM DETAIL
RAKE TRIM DETAIL
ROOF PANEL
ROOF PANEL
STITCH SCREW
(1'-0" O.C.)
STITCH SCREW
(1'-0" O.C.)
TAPE SEALANT
TAPE SEALANT
GABLE TRIM
GABLE TRIM
FASTENER
FASTENER
OUTSIDE CLOSURE
OUTSIDE CLOSURE
STITCH SCREW
(EVERY RIB*)
STITCH SCREW
(EVERY RIB*)
TAPE SEALANT
TAPE SEALANT
* FASTENER SPACING TO BE 8" - 12" O.C.
* FASTENER SPACING TO BE 8" - 12" O.C.
UNIVERSAL ENDWALL DETAIL
INSIDE CLOSURE
UNIVERSAL SIDEWALL DETAIL
WALL PANEL
INSIDE CLOSURE
FASTENER
FASTENER
TAPE SEALANT
WALL PANEL
TAPE SEALANT
UNIVERSAL SIDEWALL
ROOF PANEL
UNIVERSAL ENDWALL
ROOF PANEL
STITCH SCREW
(EVERY RIB*)
STITCH SCREW
(1'-0" O.C.)
OUTSIDE CLOSURE
* FASTENER SPACING TO BE 8" - 12" O.C.
24
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
POST FRAME BUILDING DETAILS
EAVE MOLDING DETAIL
UNIVERSAL GAMBREL DETAIL
ROOF PANEL
TAPE SEALANT
INSIDE CLOSURE
FASTENER
ROOF PANEL
TAPE SEALANT
INSIDE CLOSURE
FASTENER
EAVE MOLDING
GAMBREL FLASHING
OUTSIDE CLOSURE
OUTSIDE CLOSURE
STITCH SCREW
(EVERY RIB*)
STITCH SCREW
(EVERY RIB*)
WALL PANEL
ROOF PANEL
FASTENER
* FASTENER SPACING TO BE 8" - 12" O.C.
* FASTENER SPACING TO BE 8" - 12" O.C.
DOUBLE ANGLE DETAIL
ANGLE BASE DETAIL
WALL PANEL
WALL PANEL
FASTENER
FASTENER
TAPE SEALANT
INSIDE CLOSURE
DOUBLE ANGLE
OUTSIDE CLOSURE
WALL PANEL
TAPE SEALANT
INSIDE CLOSURE
ANGLE BASE
25
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
POST FRAME BUILDING DETAILS
DRIP CAP DETAIL
BASE MOLDING DETAIL
WALL PANEL
WALL PANEL
FASTENER
FASTENER
TAPE SEALANT
INSIDE CLOSURE
DRIP CAP
TAPE SEALANT
POST TRIM
INSIDE CLOSURE
WALK THROUGH
DOOR
BASE MOLDING
NATIONAL TRACK COVER DETAIL
CANNONBALL TRACK COVER DETAIL
WALL PANEL
WALL PANEL
FASTENER
FASTENER
TAPE SEALANT
INSIDE CLOSURE
TAPE SEALANT
INSIDE CLOSURE
CANNONBALL TRACK
COVER
NATIONAL TRACK
COVER
METAL SIDING
ON DOOR
SLIDING DOOR
26
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
POST FRAME BUILDING DETAILS
DOOR JAMB DETAIL
MINI-ANGLE / U-FLASHING DETAIL
OVERHEAD DOOR
WALL PANEL
FASTENER
DOOR JAMB
FASTENER
J-CHANNEL
MINI-ANGLE
FASTENER
WALL PANEL
FASTENER
DOOR POST TRIM DETAIL
POST TRIM DETAIL
OVERHEAD DOOR
OVERHEAD DOOR
FASTENER
FASTENER
POST TRIM
DOOR POST TRIM
FASTENER
FASTENER
J-CHANNEL
WALL PANEL
27
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
POST FRAME BUILDING DETAILS
OVERHEAD DOOR TRIM DETAIL
SOFFIT DETAIL
WALL PANEL
FASTENER
ROOF PANEL
TAPE SEALANT
INSIDE CLOSURE
OVERHEAD DOOR
TRIM
INSIDE
CLOSURE
OVERHEAD DOOR TRIM
FASTENER
FASTENER
WALL PANEL
FASTENER
WALL PANEL
* FASTENER SPACING TO BE 8" - 12" O.C.
24" SOFFIT DETAIL
12" SOFFIT DETAIL
ROOF PANEL
TAPE SEALANT
INSIDE CLOSURE
INSIDE
CLOSURE
FASTENER
12" SOFFIT
24" SOFFIT
FASTENER
J-CHANNEL
FASTENER
WALL PANEL
FASTENER
J-CHANNEL
FASTENER
WALL PANEL
28
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
INSTALLATION OVERVIEW
INSTALLATION OVERVIEW
As shown below with the number designations, install panel against the prevailing wind.
Make sure panels are square and plumb, to assure straight and proper alignment of the entire row of panels.
For areas with high wind considerations, closer fastener spacing may be required.
It is necessary to attach a temporary guide to the foundation to use as an alignment guide when installing siding panels.
Siphon groove side of panel must be overlapped with the non-siphon groove side of the adjacent panel (if applicable).
RIDGE DETAIL
(SEE PAGE 39)
Prevailing
Winds
VALLEY DETAIL
(SEE PAGE 40)
CHIMNEY DETAIL
(SEE PAGE 41)
ROOF PENETRATION
(SEE PAGE 41)
4
3
2
1
GABLE DETAIL
(SEE PAGE 39)
EAVE / GUTTER DETAIL
(SEE PAGE 37, 38, 40)
HIP DETAIL
(SEE PAGE 39)
29
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
RESIDENTIAL PANEL INSTALLATION
NOTE:
-Eave Molding, Gutter and Valley Flashings must first be installed before panel installation can begin.
-Panels can be installed going from either left to right or right to left / looking from eave to peak.
INSTALLING INSIDE CLOSURES
1. Apply a row of Tape Sealant across the top leg of the Eave Molding along the width of
the building.
2. Align and place Inside Closures over the Tape Sealant. It is critical that Inside Closures are square
to building as this will control the alignment of the panels. (see page 24 to check building square).
3. Apply a row of Tape Sealant across the top of the Inside Closure (not shown for clarity).
STEP
1ING
L CLIP
TAPE SEALANT
INSIDE CLOSURE
INSTALLING FIRST PANEL
1. Install the first panel over the Inside Closure to allow for desired overhang. Make sure the panel
is square to the eave and rake.
2. Fasten through panel, closure, and sealants into decking with appropriate amount of fasteners to
meet local building code. (see fastening pattern on page 6). Fasteners must penetrate closure and
sealant.
STEP
2
3. After securing panel at eave, repeat the fastening pattern at the appropriate spacing to meet local
building codes.
FASTENER
ROOF PANEL
INSIDE CLOSURE
w/ TAPE SEALANT
30
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
RESIDENTIAL PANEL INSTALLATION
INSTALLING SECOND PANEL
1. Apply a row of Tape Sealant across and over the ribs of the first panel about 3" from panel end.
2. Install the second panel over the first panel and Tape Sealant with a 6" Endlap. Fasten through both
panels and Tape Sealant into support with appropriate amount of fasteners to meet local building
code. (see fastening pattern on page 6). Fasteners must penetrate sealant.
3. After securing panel at eave, repeat the fastening pattern at the appropriate spacing to meet local
building codes.
STEP
3
RIDGE PANEL
FASTENER
EAVE PANEL
6"
TAPE SEALANT
INSTALLING SECOND EAVE PANEL
1. Place the lapping seam of the second panel on top of previously installed panel so that panel ends
are flush at eave (see below).
STEP
4
2. Fasten through panel, closure, and Tape Sealant into support with appropriate amount of
fasteners to meet local building code. (see fastening pattern on page 6). Fasteners must penetrate
closure and sealant.
3. After securing panel at eave, repeat the fastening pattern at the appropriate spacing to meet local
building codes.
FASTENER
ANTI-
INSIDE CLOSURE
SYPHON
GROOVE*
STITCH SCREW
*PANELS WITHOUT AN ANTI-
SYPHON GROOVE REQUIRE TAPE
SEALANT IN THE SIDELAP.
FIRST PANEL INSTALLED
31
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
RESIDENTIAL DETAILS
14" UNIVERSAL RIDGE DETAIL
RIDGE / HIP COVER DETAIL
ROOF PANEL
ROOF PANEL
STITCH SCREW
(EVERY RIB*)
STITCH SCREW
(EVERY RIB*)
OUTSIDE CLOSURE (RDG)
UNIVERSAL CLOSURE (HIP)
OUTSIDE CLOSURE
TAPE SEALANT
TAPE SEALANT
FASTENER
FASTENER
14" UNIVERSAL RIDGE
RIDGE / HIP COVER
MOISTURE
BARRIER
MOISTURE
BARRIER
* FASTENER SPACING TO BE 8" - 12" O.C.
* FASTENER SPACING TO BE 8" - 12" O.C.
VENTED RIDGE DETAIL
GABLE TRIM DETAIL
ROOF PANEL
ROOF PANEL
STITCH SCREW
(EVERY RIB*)
STITCH SCREW
(1'-0" O.C.)
TAPE SEALANT
COBRA RIDGE VENT
MOISTURE BARRIER
GABLE TRIM
13" STEP RIDGE COVER
TAPE SEALANT
MOISTURE
BARRIER
FASTENER
OUTSIDE CLOSURE
STITCH SCREW
(EVERY RIB*)
TAPE SEALANT
* FASTENER SPACING TO BE 8" - 12" O.C.
* FASTENER SPACING TO BE 8" - 12" O.C.
32
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
RESIDENTIAL DETAILS
EAVE DETAIL
GUTTER DETAIL
ROOF PANEL
ROOF PANEL
MOISTURE BARRIER
FASTENER
MOISTURE BARRIER
TAPE SEALANT
FASTENER
INSIDE CLOSURE
TAPE SEALANT
INSIDE CLOSURE
DRIP EDGE (BY OTHERS)
GUTTER (BY OTHERS)
FASTENER
(1'-0" O.C.)
EAVE TRIM
PITCH BREAK DETAIL
VALLEY DETAIL
FASTENER
WALL PANEL
ROOF PANEL
PITCH BREAK
OUTSIDE CLOSURE
PANCAKE HEAD SCREW
(1'-0" O.C.)
TAPE SEALANT
STITCH SCREW
(EVERY RIB*)
FASTENER
TAPE SEALANT
UNIVERSAL CLOSURE
VALLEY
ROOF PANEL
MOISTURE
BARRIER
MOISTURE
BARRIER
FASTENER
* FASTENER SPACING TO BE 8" - 12" O.C.
33
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
RESIDENTIAL DETAILS
CHIMNEY / CRICKET DETAIL
ROOF PENETRATION DETAIL
CHIMNEY
FASTENER
RIDGE / HIP
COVER
ROOF PANEL
SIDEWALL
(FIELD CUT
AND BEND)
TAPE SEALANT
VENT PIPE
ENDWALL
(FIELD CUT
AND BEND)
RUBBER
ROOF
JACK
ROOF PANEL
FIELD
FABRICATE
FLAT SHEET
TO FIT
PLYWOOD
CRICKET
ROOF PANEL
AVAILABLE SIZES
1
1
4
8
MINI ( / " TO 1 / " O.D. PIPE)
3
4
#2 (1 / " TO 3" O.D. PIPE)
#4 (3" TO 6" O.D. PIPE)
#6 (6" TO 9" O.D. PIPE)
#8 (7" TO 13" O.D. PIPE)
UNIVERSAL
ENDWALL
UNIVERSAL
SIDEWALL
34
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
CLASSIC RIB
CARE AND MAINTENANCE
Though factory applied pre-painted finishes are very durable and will last many years, eventually it may be desirable to
thoroughly clean or repaint them.
Dirt pickup may cause apparent discoloration of the paint when it has been exposed in some dirt-laden environments for long
periods of time. In areas of strong sunlight, slight chalking may cause some change in appearance. A good cleaning will often
restore the appearance of these buildings and render repainting unnecessary. An occasional light cleaning will help maintain a
good appearance.
In many cases, simply washing the building with plain water using a hose or pressure sprayer will be adequate. In areas
where heavy dirt deposits dull the surface, a cloth or soft bristle brush and solution of water and detergent (1/3 cup of laundry
detergent per gallon of water for example) may be used. This should be followed by an adequate rinse of water. Do not use
wire brushes, abrasives, or cleaning tools which will damage the coating surface.
Mildew may occur in areas subject to high humidity but is not normally a problem due to the high inherent mildew resistance
of the baked finish that is used. To remove mildew along with the dirt, the following solution is recommended.
1/3 cup detergent (Tide® or equivalent)
2/3 cup trisodium phosphate (Solex® or equivalent)
1 quart of 5% sodium hypochlorite solution (Clorox® or equivalent)
3 quarts of water
Strong solvents and abrasive type cleaners should be avoided. Most organic solvents are flammable and toxic and must be
handled accordingly. When using a solvent, consult maintenance professionals and label instructions for proper handling
and disposal of washings. If required, a mild solvent such as mineral spirits can be used to remove caulking compounds,
oil, grease, tars, wax, and similar substances. Use a cloth dampened with mineral spirits and apply only to areas which are
contaminated. Follow up the use of this mild solvent with detergent cleaning and rinsing.
DO NOT USE A
WIRE BRUSH
HOSE OR PRESSURE SPRAY
FOR ADEQUATE CLEANING
USE MILD DETERGENT AND WATER
FOR HEAVY DIRT DEPOSITS
35
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
®
NOTES
CLASSIC RIB
36
© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 6/14
|