Maretron Tp Aap 1 User Manual

Installation Instructions  
Maretron TP-AAP-1 TMP100 Ambient Air Temperature Probe  
NOTE: The TP-AAP-1 ambient air temperature probe is not intended for measuring the temperatures of  
liquids. Please use the TP-IP-1 immersion probe for liquid temperature measurement applications.  
Instructions  
Please follow these instructions to connect the TP-AAP-1 ambient air temperature probe to the NMEA 2000®  
network via a Maretron TMP100 Temperature Module. The wiring diagram appears in Figure 1 below. The  
diagram shows a connection to channel #4, but connections to other channels are similar. Please note that the  
TP-AAP-1 may be connected only to channels #2, #3, #4, and #5. It may not be connected to channels #0 and  
#1.  
1. Using a cable clamp or other means, secure the TP-AAP-1 so that the sensor is in the ambient air whose  
temperature is being measured.  
2. The TP-AAP-1 cable contains one red and one black wire. Connect the black wire to the appropriate Tx-  
terminal on the TMP100 as shown in Figure 1 below.  
3. Connect the red wire to the appropriate Tx+ terminal on the TMP100 as shown in Figure 1 below.  
4. Use a DSM250 (firmware 1.3.8 or greater) or other Maretron display product capable of configuring the  
TMP100 to configure the “Channel #x Source” to the type of temperature you are measuring.  
5. Use a DSM250 (firmware 1.3.8 or greater) or other Maretron display product capable of configuring the  
TMP100 to configure the “Channel #x Instance” to a number that is unique across the network for the  
source you have selected. In other words, if you are measuring Freezer Temperature, there may be only  
one channel on the network that measures Freezer Temperature that has an instance number of 0.  
Number further Freezer Temperature channels as instance #1, #2, and so on.  
6. If desired, use DSM250 (firmware 1.3.8 or greater) or other Maretron display product capable of  
configuring the TMP100 to configure the “Channel #x Label” to a text string that allows you to identify the  
particular temperature that is being measured by this probe. For example, if you have two freezers, you  
may wish to label one of them “Port Freezer” and the other “Starboard Freezer”.  
7. Using a Maretron DSM250 or Maretron N2KView, show the temperature with the source and instance you  
have selected and verify that you see a valid temperature on the display.  
TP-AAP-1 Ambient Air Probe  
TMP100 Screw Terminals  
1
2
3
4
5
6
7
8
9 10 11 12  
Figure 1 – Wiring Diagram  
Maretron, LLP  
9014 N. 23rd Ave #10  
Phoenix, AZ 85021  
Telephone: (+1) 866-550-9100  
Copyright © 2011 Maretron, LLP All Rights Reserved  
P/N: M002103 Rev.1.1 1/11  

Xerox Phaser Color Printer 8400 User Manual
Whirlpool Air Cleaner Wp Ap510 User Manual
Vinotemp 8500ssh User Manual
Toshiba E Studio 3511 User Manual
Source Technologies Ac048x1222a User Manual
Soleus Air Gb Pac 08e4 User Manual
Sanyo Spw Umr224exh56 User Manual
LG 58UH6300 02 User Manual
HITACHI CP X4022WN User Manual
Delta 14 Multichoice Manual