Operating and Installation
Instructions
Internal/External Blower
DRIB XL, DRIB XXL
DREB XL, DREB XXL
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 09 824 330
IMPORTANT SAFETY INSTRUCTIONS
,WARNING
READ AND SAVE THESE
INSTRUCTIONS
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
Keep these operating instructions in
a safe place and pass them on to any
future user.
OBSERVE THE FOLLOWING:
a) Use this appliance only in the
~
manner intended by the manufacturer.
If you have questions, contact Miele.
Read these Instructions carefully
before installing or using the
Ventilation System.
b) Before servicing or cleaning the
~
appliance, switch power off at the
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally. If
the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
This appliance is intended for
residential use only. Use the appliance
only for its intended purpose.
~
This appliance complies with current
~
safety requirements. Improper use of
the appliance can lead to personal
injury and material damage.
c) Be certain your appliance is
properly installed and grounded by a
qualified technician.
~
,CAUTION
For General Ventilating Use
Only. Do Not Use To Exhaust
Hazardous Or Explosive
Materials And Vapors.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician.
This appliance is designed to vent
~
cooking smoke and odors only.
This appliance is not designed for
~
maritime use or for use in mobile
installations such as recreational
vehicles or aircraft. However, under
certain conditions installation in these
applications may be possible. Please
contact your Miele dealer or the Miele
Technical Service Department with
specific requirements.
3
IMPORTANT SAFETY INSTRUCTIONS
d) Before connecting the appliance
Installation
~
to the power supply make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply.
This data must correspond to prevent
appliance damage. If in doubt consult a
qualified electrician.
,WARNING
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
e) Installation work and repairs a) Installation work and electrical
should only be performed by a qualified wiring must be done by qualified
~
~
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous.
person(s) in accordance with all
applicable codes and standards,
including fire-rated construction.
b) Sufficient air is needed for
~
f) Only open the housing as
described in the enclosed "Installation
combustion and exhausting of gases
through the flue (chimney) of fuel
diagram" and in the "Cleaning and care" burning equipment to prevent back
~
section of this manual. Under no
circumstances should any other parts
of the housing be opened. Tampering
with electrical connections or
components and mechanical parts is
highly dangerous to the user and can
cause operation faults.
drafting. Follow the heating equipment
manufacturer’s guideline and safety
standards such as those published by
the National Fire Protection Association
(NFPA) and the American Society for
Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and
the local code authorities.
g) Before discarding an old
~
appliance, disconnect it from the power
supply and remove the power cord to
prevent hazards.
c) When cutting or drilling into the
~
wall or ceiling, do not damage electrical
wiring and other hidden utilities.
d) Ducted hoods must always be
~
vented to the outdoors.
Use
Do not use a steam cleaner to clean
~
e) Any fittings, sealant, or materials
~
the appliance. Steam could penetrate
electrical components and cause a
short circuit.
used to install the ductwork must be
made of approved non-flammable
materials.
,WARNING
TO REDUCE THE RISK OF
FIRE USE ONLY METAL
DUCTWORK.
4
Functional description
Internal blower DRIB
External blower DREB
The internal blower DRIB XL should
only be used in combination with Miele
Range Hoods DAR 1120, 1130 or
DAR 1220, 1230.
The external blower DREB XL should
only be used in combination with Miele
Range Hoods DAR 1120, 1130 or
DAR 1220, 1230.
The internal blower DRIB XXL should
only be used in combination with Miele
Range Hoods DAR 1130, 1150 or
DAR 1230, 1250.
The external blower DREB XXL should
only be used in combination with Miele
Range Hoods DAR 1130, 1150 or
DAR 1230, 1250.
The blower will be installed into the
Range hood. Please refer to the
operating and installation instructions
for the range hood.
It must be mounted outside the kitchen
on an external wall.
The external blower is connected to the
ventilation system by an exhaust duct
and connecting cable. It is operated by
using the ventilation system control
panel.
The external blower is equipped with a
non-return flap so that no exchange of
outside air and room air can occur
when the ventilation system is off.
It is closed when the ventilation system
is off.
When the blower is turned on, the
non-return flap opens so that the
exhaust air can be directed outside.
5
Appliance dimensions
a Exhaust air connection
b Connecting cable to the range hood. If necessary, use the 10 ft. (3 m)
extension cord supplied.
6
Installation
a Air extraction with internal blower DRIB XL or XXL.
b Recirculation with internal blower DRIB XL and conversion kit DRUU.
c Air extraction with external blower DREB XL or XXL.
7
Installation
8
Installation
Installation DRIB XL/XXL into
the range hood
^ Feed the exhaust duct c through the
wall and secure it to the motor unit
fixing bracket with a hose clip.
^ Please refer to the operating and
installation instructions supplied with
the range hood.
^ Apply a sealant along the outside
edge on the rear wall of the blower
housing.
Installation DREB XL/XXL on
an external wall
^ Mount the external blower on the
external wall using four screws d.
^ Seal the screw heads.
If unsure or unfamiliar with these
installation procedures, please
contact Miele.
^ The ducting is then connected to the
cooker hood.
If using 8" (203 mm) ducting C, insert
the reducing collar e supplied into
the exhaust connection, and secure
the exhaust ducting to the reducing
collar with a hose clip. (See
Select a suitable installation location.
– Make sure that there are no
supporting elements, electrical or
piping in the wall at the selected
location.
"Connection for air extraction").
^ Place the exhaust ducting on the
blower connection f for the
ventilation hood.
– Install the external blower with the
exhaust outlet facing downwards.
^ The external blower must be installed
on a level surface.
If necessary, remove the wall
covering at the installation location.
^ See "Air Extraction" for additional
instructions on installation the
ducting.
^ Screw the fixing brackets a on the
backside of the the blower housing.
Electrical connection
See “Electrical connection” and
“Important Safety Iinstructions”
before connecting to the electrical
supply.
^ Make an hole for the exhaust duct
and the connecting cable.
The external blower DREB XL and the
range hood are connected by a 8"
(203 mm) exhaust duct C , the
external blower DREB XXL by a 10"
(254 mm) exhaust duct C (see "Air
extraction").
^ Feed the connecting cable b with
the six-pole connectors through the
wall into the house.
9
Air extraction
Exhaust ducting and connections
,WARNING
– The ducting should be as short and
straight as possible, and the number
of sharp bends should be minimized.
Danger of toxic fumes.
– For most efficient air extraction, the
diameter of the ductwork should not
be less than 8" (203 mm) for
DRIB/DREB XL and 10" (254 mm) for
DRIB/DREB XXL. Use of flat ducts
also reduces the air extraction
efficiency.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
To reduce the risk of fire and to
properly exhaust air, the exhaust
gases extracted by the hood
should be vented outside of the
building only.
– Noise levels of the hood will increase
if flat ducts or round ducts of less
than than 8" (203 mm) for
Do not vent exhaust air into
spaces within walls or ceilings or
in attics, crawl spaces or garages.
DRIB/DREB XL and 10" (254 mm) for
DRIB/DREB XXL in diameter are
used.
To reduce the risk of fire, only use
metal ductwork.
– Use smooth or flexible pipes made
from approved non-flammable
materials for exhaust ducting.
Please read and follow the
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
– Where the ductwork is horizontal, it
must slope away from the hood at
least 1/8" per foot (1 cm per meter) to
prevent condensation dripping into
the appliance.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
10
Electrical connection
,WARNING
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Important: To increase security
before the machine is installed, it is
recommended to install a protective
switch (30 mA).
All electrical work should be
performed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA
70) and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
Ensure that power to the appliance
is off while installation or repair work
is performed.
^ Connect the blower to the cooker
hood using the connecting cable and
the 6-pole plug connector.
The blowers DRIB/DREB XL may
only be operated with Miele
DAR 1120, 1130, or DAR 1220, 1230
Range hoods.
The blowers DRIB/DREB XXL may
only be operated with Miele
DAR 1130, 1150, or DAR 1230, 1250
Range hoods.
^ Use the extension cable supplied to
lengthen the cabling if necessary.
Maximum load
DRIB, DREB XL . . . . . . . . . . . . . . 615 W
DRIB, DREB XXL . . . . . . . . . . . . . 800 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
^ Verify that the voltage, load and
circuit rating information found on the
data plate, match the household
electrical supply before installing the
blower.
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit Rating . . . . . . . . . . . . . . . . . 15 A
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or contact Miele’s
Technical Service Department. See
back cover for contact information.
11
After Sales Service
Repairs
In the event of a fault which you cannot
easily fix yourself, please contact the
Miele Technical Service Department.
^ When contacting the Technical
Service Department, please have the
model and serial number of your
appliance available.
These can be found on the data plate.
12
Caring for the environment
Disposal of packing material
Disposal of an old appliance
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling center about the
possibility of recycling these materials.
Before discarding an old appliance,
disconnect it from the electrical
supply and cut off the power cord to
prevent it from becoming a hazard.
,DANGER
Ensure that any plastic wrappings,
bags, etc., are disposed of safely
and kept out of the reach of babies
and young children. Danger of
suffocation!
13
14
15
Alteration rights reserved / 4613
M.-Nr. 09 824 330 / 00
INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST
CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
|