GE CSWONBLPWF1NN User Manual

Smart Wall Switch  
Installation Guide  
On/Off Switch  
Models  
CSWONBLBWF1NN  
CSWONBLPWF1NN  
CSWONBLTWF1NN  
Simple DIY Setup  
Install  
your Smart  
Switch  
Download  
the C by GE app  
Add  
your Smart Switch to  
the C by GE app  
Compatibility Requirements  
Rating 120V AC 60Hz  
Works with halogen,  
incandescent and LED bulbs,  
including C by GE Smart  
Bulbs.  
Neutral wire is required  
(Wire is usually white  
or grey)  
LED up to 1.25 amps  
Ground wire is required  
(Wire is usually green,  
green with a yellow stripe,  
or copper)  
Incandescent/halogen  
up to 5 amps  
Motor up to 1/4HP  
Wi-Fi 802.11 b/g/n @ 2.4 GHZ  
is required  
! IMPORTANT NOTE ON 3-WAY WIRING:  
Some lights have one wall switch, while others are controlled by two or  
more wall switches (such as stair lights, which have a switch at both the  
top and bottom of the stairs). If your lights have more than one switch  
(called a 3-way), we’ve created instructions for how to install and  
enable the capability.  
Visit cbyge.com/switch-support  
for 3-way installation instructions and how-to-videos.  
Let’s Do It  
INCLUDED  
On/Off Switch  
Wall Plate  
4 Wire Nuts  
Bulb Adaptor  
Line/Load  
Line/Load Ground  
2 Phillips Mounting Screws  
2 Phillips Face Plate Screws  
Wire Labels  
12  
YOU’LL  
NEED  
Phillips Screwdriver  
9
3
6
Needle Nose Pliers  
(recommended)  
Approximately  
30 minutes of your day  
to install and setup  
the switch  
Voltage Tester  
(recommended)  
You Got This!  
And we’re here to help.  
For in-depth instructional videos  
and a guided tour through the installation,  
go to cbyge.com/switch-support.  
BEFORE YOU DO ANYTHING: Step 1  
Turn Off The Power!  
1. Turn off the power for the switch location at the circuit breaker box.  
2. Test existing switch by toggling switch on/off, ensuring lights do not turn on.  
3. Now, follow these setup steps for a single gang switch.  
ON  
OFF  
IF APPLICABLE  
Install adaptor onto  
C by GE smart or  
non-dimmable LED bulbs  
1. C by GE smart switches and dimmers are compatible with C by GE smart bulbs.  
To keep your C by GE bulbs always available and connected, the included  
bulb adaptor should be used to have full control of C by GE bulbs on the same  
circuit as the switch.  
NOTE: Only one bulb adaptor is needed per switch, even if there are multiple  
C by GE bulbs on the circuit.  
2. Simply twist the bulb adaptor onto the base of one C by GE smart bulb  
and Screw into the fixture.  
NOTE: Keep your bulb adaptor handy. Even if you don’t have C by GE bulbs,  
the bulb adaptor can be used to improve the performance of some traditional  
LED bulbs if you begin experiencing any performance issues.  
If installing in a recessed can application, you may need to adjust the depth  
of the recessed can to ensure the bulb is flush.  
Go to: cbyge.com/switch-support for more helpful tips on when to use  
the bulb adaptor.  
IF APPLICABLE  
Install adaptor onto  
C by GE smart or  
non-dimmable LED bulbs  
STEP 2  
Remove Your Old Switch  
1. Remove the existing wall plate and switch from the wall.  
2. Use voltage tester on the black wires to confirm power to the  
switch is off (recommended).  
3. Before disconnecting the wires from the wall, label each with  
the provided wire labels.  
Ground wire is required.  
If you don’t have this wire, the C by GE switch  
is not compatible.  
4. Disconnect wires and remove existing switch.  
Line/Load  
Line/Load Ground  
Wire Labels  
STEP 3  
Connect The Wires  
NOTE: Both black wires on the switch are interchangeable  
and can be connected to either the load or line wire from the wall.  
1. Connect the first line/load (black) wire on the switch to the line  
or load (black label) wire from the wall.  
2. Connect the second line/load (black) wire on the switch to the line  
or load (black label) wire from the wall.  
3. Connect the ground  
(green) wire on the switch with the ground  
(green label) wire from the wall.  
4. Cap the 3-way/multi-way traveler wire (if applicable).  
For 3-way switch setup, visit cbyge.com/switch-support  
5. Cap the neutral wire from the wall (if applicable).  
Neutral wire is not required to operate this switch.  
Attention: Incorrectly connecting the Ground wire from the wall  
to the Line or Load wire on the switch will damage the product.  
3/4 inch  
USING WIRE NUTS  
1. Insert wires into wire nut.  
2. Turn wire nut clockwise.  
3. Pull gently on wires to test connection.  
STEP 4  
Fit Wires Into Wall Box  
Neatly push the wires back into the box, rotating the switch so it’s oriented  
according to the image.  
On/Off  
Switch  
STEP 5  
Secure The Switch  
1. Using a Phillips screwdriver and the screws provided, secure the switch  
to the wall until level and flush.  
2. Screw on the faceplate bracket, then snap the faceplate cover  
onto the bracket.  
STEP 6  
Turn The Power Back On  
After the switch is secured and faceplate mounted,  
turn the power back on at the circuit breaker box.  
At the switch, LED indicator light or light ring will flash blue indicating the  
device is wired correctly and the device is in setup mode. Press any button  
on the switch to enable setup mode if setup mode times out.  
ON  
OFF  
STEP 6  
Turn The Power Back On  
LED indicator light or light ring will flash blue until the switch is added  
to the C by GE app.  
LED indicator light or light ring will flash red if the circuit is overloaded.  
Max load rating 1.25 amps for LED and 5 amps for incandescent/halogen.  
LED indicator light or light ring will not illuminate if wired incorrectly.  
IF LIGHTS DON’T TURN ON:  
1. Check that power to the switch is on at the breaker.  
2. Turn power off at the breaker, return to the switch to confirm the wires  
are securely and properly wired according to the installation guide.  
3. Go to cbyge.com/switch-support for more troubleshooting.  
Congratulations!  
You’ve completed the Smart Switch installation.  
Next...  
Download  
the C by GE app  
Add  
Setup  
your Smart Switch to  
the C by GE app  
your Alexa or  
Google voice  
assistant (optional)  
Enable Your Voice Assistant  
Amazon Alexa  
To setup, open the Alexa app, search for the C by GE skill,  
follow the setup instructions.  
Try this...  
Alexa, turn off the living room.  
Alexa, turn on the bedroom.  
Google Assistant  
To setup, open the Google Assistant or Google Home app, search for the  
C by GE action, follow the setup instructions.  
Try this...  
Hey Google, turn on the lights.  
Hey Google, good morning.  
Hey Google, I’m leaving.  
Additional Information and Warnings  
FCC Compliance Statement Compliance Notice:  
This equipment has been tested and found to comply with the limits for a Class B  
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful interference in a residential  
installation. This equipment generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instructions, may  
cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this  
equipment does cause harmful interference to radio or television reception, which  
can be determined by turning the equipment off and on, the user is encouraged  
to try to correct the interference by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the equipment and receiver.  
• Connect the equipment into an outlet on a circuit different from that to  
which the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
This device complies with part 15 of FCC rules. Operation is subject to the  
following two conditions:  
1. This device may not cause harmful interference.  
2.This device must accept any interference received, including  
interference that may cause undesired operation.  
Changes or modifications that are not expressly approved by the  
manufacturer could void the user’s authority to operate the equipment.  
RF Exposure Information:  
This equipment complies with FCC radiation exposure limits set forth for an  
uncontrolled environment. In order to avoid the possibility of exceeding the FCC  
radio frequency exposure limits, human proximity to the antenna shall not be less  
than 8 inches during normal operation.  
RF Exposure Statement:  
This equipment complies with IC RSS-102 radiation exposure limits set forth for an  
uncontrolled environment. This transmitter must be installed to provide a  
separation distance of at least 8 inches from all persons and must not be  
collocated or operating in conjunction with any other antenna or transmitter.  
CAUTION  
For supply connections, use copper wire only rated at 75C.  
High Voltage - Disconnect power supply before servicing  
Operation temperature: 0-40ºC  
For Control of Electronic Ballast, CFLs, LED, and LED Lamps.  
Type 1 Enclosure  
IP20  
Pollution Degree 2  
Impulse Voltage: 2500V  
Type 1 action  
Indoor use only.  

Xerox Docuprint 4850 User Manual
Soleus Air Gm Pac 12e1hp User Manual
Samsung Aw10ph Series User Manual
Radio Shack 23 043 User Manual
Panasonic Kx Tcd515e User Manual
MAKITA G6101R User Manual
LG LT1030CR User Manual
JONSERED CS 2240S User Manual
GE ASP14 User Manual
BLACK DECKER PI200AB User Manual