SKU# 1004 166 083
INSTRUCTION
MANUAL
TM
OFF
ON
REMOTE CONTROL
400W GROUND FOG MACHINE
WITH WIRELESS REMOTE
1-877-527-0313, 8 a.m. to 5 p.m., EST,
Monday-Friday
If an extension cord (or a long detachable power-supply cord) is used:
● The marked electrical rating of the detachable power-supply cord or extension cord
should be at least as great as the electrical rating of the appliance.
● If the appliance is of the grounded type, the extension cord should be a grounding type
3-wire cord.
● The longer cord should be arranged so that it will not drape over the countertop or
tabletop where it can be tripped over, snagged or pulled on unintentionally (especially
by children).
BATTERY USAGE
1. Keep these instructions for future reference because they contain important information.
2. Do not mix alkaline and standard (carbon-zinc) batteries.
3. Do not mix old and new batteries.
4. Non-rechargeable batteries are not to be recharged.
ADDITIONAL INFORMATION
1. It is normal for condensation to appear on the nozzle of the Fog Machine.
2. A small amount of fog may spray during or after operation.
3. The unit will have to reheat after long bursts of use. The unit will stop operation for a
short period in order to heat up to operating temperature again. While this is happening,
fog cannot be produced. The light on the Receiver will turn on again when the unit is
ready to generate more fog.
INTRODUCTION:
• Congratulations on the purchase of your new Ground Fog Machine. This unit is supplied
with a wireless remote control and a water bag.
• To assist with the care and use of the product we have prepared this short user manual.
Handle
Ice Box Cover
Nut
Fluid Tank
Wireless Receiver
Preheat working light
Nozzle
Manual Activation Switch
Plug
OFF
ON
REMOTE CONTROL
Wireless Remote
2
Ground Fog liquid level indicator
Power switch
with working light
THE OUTLET
DO
NOT
CONT
GROUNDING
TERMINAL,
ONL
AIN
Timer cable jack
Y
FOR
REMOTE-CONTROL
(Timer cable not included)
ON
OFF
Fuse:
T5A, 125V
Fuse
Power supply
220V
AC,60Hz
Power cord
(120V AC, 60Hz)
Water Tube
Gather Water Bag
FOG MACHINE TECHNICAL SPECIFICATIONS:
Model: F- 40 GB
Fuse: 5A, 125V
Rating Voltage: AC 120V, 60Hz
Power: 400W
Ambient Temperature: 14~ 113°F
Preheat Time: 2.5~3.5 Minutes
Tank Capacity: 1 Liter / 1.05 Quart
Dimensions: 410 L x 210 W x 190 H mm
16.14 L x 8.26 W x 7.48 H inch
GENERAL ASSEMBLY AND OPERATION INSTRUCTIONS
High quality ground fog
Ice cubes
liquid (not included)
(not included)
GROUNDING
AIN
TERMINAL,
ONL
REMOTE-CONTROL
Y
Full
FOR
Step 1
Step 2
ON
OFF
Red Line
Fuse:
T5A, 125V
Power supply
220V
AC,60Hz
Empty
Step 1: Remove the cap of the fluid tank
to fill with high quality ground fog liquid.
Step 2: Loosen the nut on the ice box cover to
open. Fill the ice container with ice cubes then
close the ice box cover and tighten the nut.
NOTE: THE AMOUNT OF FLUID CANNOT
EXCEED THE “FULL” MARK ON LEVEL
INDICATOR. PLEASE ADD GROUND
FOG LIQUID WHEN THE AMOUNT OF
LIQUID IN THE “RED LINE” MARK ON
LEVEL INDICATOR.
NOTE: THE CAPACITY OF THIS ICE BOX IS
APPROXIMATELY 1.9 LITER.
3
Standard 120V
household outlet.
Step 3
Step 4
THE OUTLET
DO NOT CONT
G
ROUNDING
AIN
TERMINAL,
O
N
L
Y
F
OR
REMOTE-CO
NTRO
L
ON
O
F
F
Fuse:
T5A, 125V
Power supply
220V
AC,60Hz
Step 3: Open the cap on the water bag plug Step 4: Plug the power supply into a standard
and insert the water tube into the water bag. 120V household outlet.
When ice melts into water, water will flow
into the water bag.
Batteries are
included
Wireless Remote
Step 5
Step 5: Open battery cover on back of wireless remote. Insert the new 2 X 1.5 V AAA batteries
inside. Please observe the correct polarities during installation and follow all battery instruc-
tions.
Red Light
ON
12
OFF
Fuse:
T5A, 125V
Power supply
0V
AC,60Hz
Full
ON
Step 6
Warm-up 2.5~3.5
minutes
Step 6: Push the power switch into the ON position and the working
light will illuminate. Allow the machine to warm-up 2.5~3.5 minutes.
When the warm-up is complete the preheat red light will illuminate, this
means the ground fog machine is ready to emit fog.
4
12
Step 7
Spray up Fog
30~50 Seconds
12
ON
O
F
F
REMOTE
CONTROL
Reheat
40~60 Seconds
6.1 m / 20 ft
Step 7: Wireless Remote Activation: Point wireless remote towards the wireless receiver
dome located on top of the ground fog machine. Press the “ON” button and the ground fog
machine will spray fog 30~50 seconds. Press the “OFF” button to stop. The machine will
automatically stop when it needs to reheat. Wait for the preheat red light to come on before
operating again.
Step 8
Step 8: Manual Activation: Simply press and hold the “Manual Activation Switch” to ON locat-
ed on the top of the ground fog machine. The ground fog machine will spray fog for 30~50
seconds. Release the switch to return to OFF position. The machine will automatically stop
when it needs to reheat, Wait for the preheat red light to come on before operating again.
IMPORTANT: Always monitor the liquid level in the fluid tank and the water bag while using
the machine. When the fluid tank is empty you should turn off the machine to add ground fog
liquid into the tank. When the water bag is full of water you should turn off the machine,
empty the water bag and then reinsert the water tube into the water bag.
When not using the ground fog machine please turn off the power switch and unplug the
power cord from the outlet. Open the ice box cover to empty any excess ice cubes from the
ice container. Empty the water bag.
5
REPLACING THE FUSE:
If the Fog Machine does not work at all when it is connected to the power socket, then it is
probably that the fuse has been broken, Please replace the fuse as outlined below.
Risk of electric shock and fire, Disconnect from power
socket before replacing the fuse.
1. Turn the fuse knob counterclockwise to reveal the fuse.
2. Replace the fuse with the same size and type fuse: 5A, 125V.
3. Place fuse in cover and reinstall by turning clockwise. Be sure not to over tighten.
MAINTENANCE AND SERVICING
Note: Use of ground fogger liquids not included or those other than HOME DEPOT ground fog
liquid are not recommended and may result in blockage, leakage, or other damage to the unit.
TROUBLE SHOOTING:
Problem
Solution
1. Check the plug to ensure it is properly inserted into the outlet. The power
switch should be in the ON position and the red indicator light illuminated.
2. Check the ground fog liquid level. If it is too low, add ground fog liquid
according to the level indicator.
The ground
fog machine
does not
work
3. The machine requires 2.5 to 3.5 minutes to warm-up. Please allow
sufficient time for the machine to warm up properly and for the green
pre-heat indicator light to come on.
4. Check all wire connections are in working ordered and not obstructed.
1. Check the wireless remote have insert new batteries according to the
correct polarity.
The wireless
remote does
not work
2. Check the wireless remote and the ground fog machine are the correct
distance. Make sure the wireless remote and fog machine are within 20ft
(6.1m) of each other. The remote will not work properly if this distance is
exceeded.
If you are still experiencing problems with the product please call
1-877-527-0313 for instructions.
6
INSPECTION
Before each use, check unit for any cracks in the enclosure, remote control, cords and
plugs. Make sure there are no exposed wires. Do not use if any of the above conditions are
found.
CLEANING
Should you experience low fog output after many hours of continuous operation or after
the machine has been idle or in storage for a long time, it is recommended to run a
cleaning solution through the system to prevent the accumulation of particles in the
heating element.
a. While the unit is unplugged and cool, empty all Fog Liquid from the machine and
replace with a fog machine cleaning solution in the tank. Plug unit in and allow to warm
as usual.
b. Run unit in a well-ventilated area until tank is empty.
c. Cleaning is now complete.
All fog machines are prone to clogging due to the consistency of Fog Liquid and the high
temperatures at which it vaporizes. However, a well maintained machine should provide
years of reliable use.
STORAGE
It is important to remove all fluid from the unit when storing for an extended period of time.
1. When the unit is unplugged and cool, empty all Fog Liquid from the machine. Plug in unit
and allow to warm as usual.
2. Run unit in a well-ventilated area for 10-seconds to confirm tank is empty and dry.
3. Store on a flat, level surface. Keep in a well-ventilated, cool and dry location.
For best performance, operate unit for 10-minutes every 3 months. Follow the Operation
Instructions and storage instructions accordingly.
04252019_2008693
MADE IN CHINA
7
|