Operating Manual - English
FUJITSU Server PRIMERGY RX1330 M4
Operating Manual
October 2018
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this
product.
Carefully read the manual before using this product. Pay particular attention to
the accompanying manual "Safety Notes and Regulations" and ensure that
these safety notes are understood before using the product. Keep this manual
and the "Safety Notes and Regulations" manual in a safe place for easy
reference while using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a
domestic environment this product may cause radio interference, in which case
the user may be required to take appropriate measures.
VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the printed circuit board
assemblies of the product and in the mouse and keyboard are limited-life
components. Use of these components beyond their operating life may result in
electrolyte leakage or depletion, potentially causing emission of foul odor or
smoke.
As a guideline, in a normal office environment (25°C) operating life is not
expected to be reached within the maintenance support period (5 years).
However, operating life may be reached more quickly if, for example, the
product is used in a hot environment. The customer shall bear the cost of
replacing replaceable components which have exceeded their operating life.
Note that these are only guidelines, and do not constitute a guarantee of
trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial
and/or industrial areas as a server.
When used as visual display workplace, it must not be placed in the direct field
of view to avoid incommoding reflections (applies only to TX server systems).
RX1330 M4
Operating Manual
The device has not been designed or manufactured for uses which demand an
extremely high level of safety and carry a direct and serious risk of life or body
if such safety cannot be assured.
These uses include control of nuclear reactions in nuclear power plants,
automatic airplane flight control, air traffic control, traffic control in mass
transport systems, medical devices for life support, and missile guidance
control in weapons systems (hereafter, "high safety use"). Customers should
not use this product for high safety use unless measures are in place for
ensuring the level of safety demanded of such use. Please consult the sales
staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply
caused by lightning. To prevent a momentary voltage drop, the use of an
uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal
Computer issued by JEITA, the Japan Electronics and Information Technology
Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade
Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which
contain such technology should not be exported from Japan or transferred to
non-residents of Japan without first obtaining authorization in accordance with
the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for Japan:
About SATA HDDs
The SATA version of this server supports HDDs with SATA/BC-SATA storage
interfaces. Please note that the usage and operation conditions differ
depending on the type of HDD used.
OperatingManual
RX1330 M4
For more information on the usage and operation conditions of each available
type of HDD, see the following internet address:
RX1330 M4
Operating Manual
OperatingManual
RX1330 M4
Content
RX1330 M4
Operating Manual
Content
5.6
Configuring the server with
5.7
Configuring the server without
OperatingManual
RX1330 M4
Content
RX1330 M4
Operating Manual
Content
OperatingManual
RX1330 M4
1
Introduction
This operating manual describes how to install, set up and operate your server.
This operating manual is intended for those responsible for installing the
hardware and ensuring that the system runs smoothly. It contains all the
information you need to put your PRIMERGY RX1330 M4 into operation.
To understand the various expansion options, you will need to be familiar with
the fields of hardware and data transmission and you will require a basic
knowledge of the underlying operating system.
1.1
Notational conventions
The following notational conventions are used in this manual:
Text in bold
Indicates references to names of interface elements.
Indicates commands.
Text in
monospace
"Quotation marks" Indicate names of chapters and terms that are being
emphasized.
Ê
Describes activities that must be performed in the order
shown.
V
CAUTION! Pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
I
Indicates additional information, notes and tips.
RX1330 M4
Operating Manual
11
Introduction
12
OperatingManual
RX1330 M4
2
Before you start
Before you start to install, set up and operate your server, please proceed as
follows:
Ê
Carefully read the safety instructions in chapter "Important information" on
2.1
Documentation overview
To get an overview on all documents for your server, see the following table.
I
All documentation on PRIMERGY hardware and ServerView software is
available online from the Fujitsu manuals server at:
For Japan:
The complete PRIMERGY documentation set can also be downloaded
as a DVD ISO image at:
For Japan:
Document
Description
"Safety Notes and Regulations"
manual
" 安全上のご注意 " for Japan
Important safety information, available
online, or as a printed copy
"FUJITSU Server PRIMERGY
Information how to install, set up and
RX1330 M4 Operating Manual" operate your server, available online
"FUJITSU Server PRIMERGY
RX1330 M4 Upgrade and
Maintenance Manual"
Instructions for upgrading the server
configuration or replacing defective
hardware, available online
"D3675 BIOS Setup Utility for
FUJITSU Server PRIMERGY
RX1330 M4 Reference Manual"
Information on configurable BIOS options
and parameters, available online
Table 1: Documentation overview
RX1330 M4
Operating Manual
13
Before you start
Document
Description
Label inside the top cover outlining
connectors, indicators and jumper
System foil
Various system information, such as the
product name, serial number, order
number, MAC addresses and DNS name
(for Japan, only the product name and the
serial number)
ID card
The location of the ID card can be found in
the overview of the server.
–
–
–
–
"ServerView Suite Local Service
Concept (LSC)" user guide
"ServerView Operations Manager -
Server Management" user guide
"iRMC S5 - Concepts and Interfaces“
user guide
Software documentation
"iRMC S5 - Configuration and
Maintenance" user guide
–
–
"iRMC S5 - Web Interface" user guide
"ServerView embedded Lifecycle
Management (eLCM)" user guide
Spare parts identification and information
system (not valid for Japan), available for
online use or download (Windows OS) at
ares or from the CSS component view of
the ServerView Operations Manager
Illustrated Spares catalog
Glossary
Contains abbreviations and explanations,
available online
Important information on warranty
regulations, recycling and service,
available online, or as a printed copy
"Warranty" manual
" 保証書 " for Japan
Table 1: Documentation overview
14
OperatingManual
RX1330 M4
Before you start
Document
Description
"Returning used devices"
manual
Recycling and contact information,
available online at
http://ts.fujitsu.com/recycling, or as a
printed copy
"Service Desk" leaflet
Not applicable in Japan and other countries
that have different regulations for recycling
"サポー ト &サービス " for Japan
RAID documentation, available online at
Servers - Expansion Cards - Storage
Adapters
Additional documentation
For Japan:
–
Operating system documentation,
online help
Third party documentation
–
Peripherals documentation
Table 1: Documentation overview
RX1330 M4
Operating Manual
15
Before you start
16
OperatingManual
RX1330 M4
Product description
3.1
Overview of the server
Figure 1: Server front
Pos. Component
1
2
3
ODD
ID card
Front panel module (not on 10x HDD/SSD version)
HDD/SSD:
4x 3.5-inch HDD OR
4
5
8x 2.5-inch HDD/SSD OR
4x 2.5-inch PCIe SSD and 4x 2.5-inch HDD/SSD OR
10x 2.5-inch HDD/SSD
Front panel on QRL (only on 10x HDD/SSD version)
18
OperatingManual
RX1330 M4
Product description
3.2
Features
Customer Self Service (CSS)
The PRIMERGY Customer Self Service (CSS) concept enables you to identify
and replace the affected component yourself in the case of certain error
scenarios.
In the CSS concept, you can replace the following components yourself in the
event of an error:
–
–
–
–
–
Hot-plug HDD/SSD modules
Hot-plug PSUs
Memory modules
System fans
Expansion cards
For more information on replacing these components, see the "FUJITSU Server
PRIMERGY RX1330 M4 Upgrade and Maintenance Manual".
CSS indicators on the front panel and I/O panel of the PRIMERGY server
provide you with information if a CSS event arises.
In addition, CSS errors are displayed in the ServerView Operations Manager,
the server management software from Fujitsu.
In the event of errors, the ServerView Operations Manager refers you directly
to the affected component and its order information in the Illustrated Spares
catalog of the server in question. (This feature is not available for Japan.)
I
More information on the CSS concept is provided in the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual on the Fujitsu
manuals server.
For the latest information on optional products provided for the
RX1330 M4, see the configurator tool of the server:
For Japan:
RX1330 M4
Operating Manual
19
Product description
System board
The features of the system board are described in the "FUJITSU Server
PRIMERGY RX1330 M4 Upgrade and Maintenance Manual". The setup
possibilities are described in the "D3675 BIOS Setup Utility for FUJITSU Server
PRIMERGY RX1330 M4 Reference Manual".
Trusted Platform Module (TPM)
A TPM for safer storage of keys can be implemented as an option. This module
enables programs from third party manufacturers to store key information (e.g.
drive encryption using Windows Bitlocker Drive Encryption).
The TPM is activated via the BIOS (for more information, see the “D3675 BIOS
Setup Utility for FUJITSU Server PRIMERGY RX1330 M4 Reference Manual").
V
CAUTION!
–
When using the TPM, note the program descriptions provided by the
third party manufacturers.
–
You must also create a backup of the TPM content. To do this, follow
the third party manufacturer instructions. Without this backup, if the
TPM or the system board is faulty, you will not be able to access your
data.
–
If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them
with your backup copies of the TPM content.
20
OperatingManual
RX1330 M4
Product description
Power supply unit (PSU)
The server can be equipped with:
–
–
One standard PSU
The PSU adjusts automatically to any mains voltage in the range of 100 V -
240 V.
Up to two hot-plug PSUs
The hot-plug PSU adjusts automatically to any mains voltage in the range
100 V - 240 V. In addition, a second hot-plug PSU can be installed optionally
to serve as a redundant power supply. If one PSU fails, the second PSU in
the redundant configuration ensures operation can continue uninterrupted
and the defective PSU can be replaced during operation (hot-plug).
–
One hot-plug PSU and one FJBU
Fujitsu battery unit (FJBU)
FJBU behaves as a modular UPS in the server. When power fail happened, the
server can operate by FJBU for a while. FJBU supports hot-plugging, and can
be replaced during operation.
Advanced Thermal Design (ATD)
The ATD option allows you to operate the system with a wider temperature
range either of 5 °C to 40 °C or 5 °C to 45 °C, depending on your system and
configuration.
This option can only be ordered from the
manufacturer and is indicated by the respective
logo on the identification rating plate.
V
CAUTION
In a system that is configured with ATD, only certain components which
support the respectively increased higher operating temperature range
may be installed and used. For applicable restrictions, see the official
configurator tool.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory
and automatically corrected with the Error Correcting Code (ECC) method.
RX1330 M4
Operating Manual
21
Product description
Automatic Server Reconfiguration and Restart (ASR&R) restarts the system in
the event of an error and automatically "hides" the defective system
components.
The Prefailure Detection and Analysis (PDA) technology from Fujitsu analyzes
and monitors all components that are critical for system reliability.
A RAID controller supports different RAID levels and increase the availability
and data security of the system.
The HDD/SSD modules provide additional availability.
iRMC S5 with integrated management LAN connector
The iRMC S5 (integrated Remote Management Controller) is a Baseboard
Management Controller (BMC) with integrated management LAN connector
and expanded functionality that was previously only available with additional
plug-in cards. In this way, the iRMC S5 enables complete control of PRIMERGY
servers, regardless of system status, and thus particularly the control of
PRIMERGY servers that are in the "out-of-band" system status.
Major functions supported by the iRMC S5 include the following:
●
●
●
Browser access via the own Web server of the iRMC S5
Secure communication (SSH, SSL)
Power Management for the managed server (depending on its system
status)
●
●
●
●
●
●
●
●
●
Power Consumption Management
Connecting virtual drives as remote storage
Text-based and graphic console bypass (Advanced Video Redirection)
Remote Storage
Command Line Interface (CLI)
Simple, interactive or script-based iRMC S5configuration
Customer Self Service (CSS)
User management of the iRMC S5
Multi-computer, global iRMC S5 user administration using an LDAP
Directory Service
●
Automatic network configuration via DNS / DHCP
22
OperatingManual
RX1330 M4
Product description
●
●
●
●
●
●
Power supply of the iRMC S5 via the system standby supply
Full-coverage alarm management
System Event Log (SEL) reading and processing
IPMI support
CIM / WS-MAN support
Internal Event Log for user login / logout auditing
More information about the iRMC S5 can be found in the iRMC S5 user guides
(on the Fujitsu manuals server under x86 Servers - Software -
ServerView Suite - Out-Of-Band Management).
Server management
Server management is implemented using the ServerView Operations Manager
supplied and the PDA technology from Fujitsu. PDA reports the threat of a
system error or overload at an early stage, allowing preventive measures to be
taken.
The ServerView Operations Manager enables the management of all
PRIMERGY servers in the network via a central console. The ServerView
Operations Manager supports the following functions:
●
●
Round-the-clock monitoring, regardless of server status
High-performance, graphical console bypass (AVR) protected by
HTTPS/SSL (128 bit)
●
●
●
●
●
●
Remote storage via USB
Remote power on
Intrusion detection in the floorstand model
Temperature monitoring of the CPU and the surrounding area
Detailed status and error reports for CPUs and main memory
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)
in the event that memory modules or CPUs fail
●
●
●
Power monitoring
End-of-life monitoring of fans with prompt notification before failure
Watchdog timer for monitoring the operating system with ASR&R
RX1330 M4
Operating Manual
23
Product description
More information on the ServerView Operations Manager is provided in the
associated documentation.
ServerView Installation Manager
You can configure the PRIMERGY server quickly and precisely with the
ServerView Installation Manager software provided. User-guided menus are
available for installing the server operating system (for more information, see
Service and support
PRIMERGY servers are easy to maintain and modular, thus enables quick and
simple maintenance.
The handles and locks (touch points) used to exchange components are
colored green to ensure simple and immediate recognition.
In order to prevent the components from being damaged by incorrect handling
when they are being installed and removed, the areas of all components that
can be touched without damaging them are also marked green.
PRIMERGY diagnostic LEDs fitted on the system board indicate which
component (memory module, CPU, fan or expansion card) is not functioning
properly.
The Flash EPROM program supplied with the Fujitsu utilities supports a fast
BIOS update.
With the iRMC on the system board, the server can also be maintained and
serviced remotely. This enables remote diagnosis for system analysis, remote
configuration and remote restart should the operating system or hardware fail.
ServerView Remote Management
ServerView Remote Management is the remote management solution from
Fujitsu for PRIMERGY servers. ServerView Remote Management and the
relevant hardware components integrated on the system board allow remote
monitoring and maintenance as well as fast restoration of operation in the event
of errors.
Remote monitoring and maintenance avoids time-consuming and costly on-site
repairs and reduces service costs. This leads to a reduction in the total cost of
ownership and an excellent return on investment for the remote management
solution.
24
OperatingManual
RX1330 M4
Product description
The administrator can access all system information and information from the
sensors such as fan speeds or voltages via the iRMC web interface. You can
also start the text-based or graphic console bypass (Advanced Video
Redirection, AVR) and connect virtual drives as remote storage.
I
More information about the iRMC can be found in the iRMC user guides
ServerView Suite - Out-Of-Band Management.
Property and data protection
The rack model is protected against unauthorized access by a lockable rack
door.
BIOS setup security functions
The Security menu in BIOS Setup offers various options for protecting your
data from unauthorized access. By combining these options, you can also
achieve optimum protection for your system.
I
A detailed description of the Security menu and how to assign
passwords can be found in the "D3675 BIOS Setup Utility for FUJITSU
Server PRIMERGY RX1330 M4 Reference Manual".
RX1330 M4
Operating Manual
25
Product description
10 HDD/SSD variant
Figure 3: Connectors on the front panel on QRL
1
1x USB 2.0 connector
The USB 2.0 connector on the front supports activities carried out by
the service technician. The maximum length of the external cable is
two meters for the USB connector on the front.
RX1330 M4
Operating Manual
27
Product description
3.3.1.2 Server rear
Figure 4: Connectors on the I/O panel
1
2
2 x USB 2.0 connectors
4
5
Standard LAN connector (LAN1)
Shared LAN connector (LAN2)
2 x USB 3.1 Gen 2
connectors
3
Video connector (VGA)
6
Management LAN connector (for
iRMC server management function)
The corresponding indicators are explained in section "Indicators on the server
I
Depending on the BIOS settings, the shared LAN connector may also be
used as a management LAN connector. For more information, see the
I corresponding BIOS Setup Utility reference manual.
Some of the devices connected require special software (e.g. drivers)
(see documentation for the connected device).
28
OperatingManual
RX1330 M4
Product description
Pos.
Label
Button
Function
Reboots the system.
Press the reset button with a straightened
end of a paper clip.
1
RESET Reset button
V
CAUTION!
Risk of data loss!
Used to troubleshoot software and device
driver errors.
Press the NMI button with a straightened end
of a paper clip.
2
NMI
ID
NMI button
ID button
V
CAUTION!
Use this button only if directed to do so
by qualified certified maintenance
personnel!
Highlights the ID indicator on the front panel
and I/O panel for easy server identification.
3
4
Used to switch the server on or off.
I
If the system is running an ACPI-
compliant operating system, pressing
the On/Off button will perform a
graceful shutdown.
On/Off
button
30
OperatingManual
RX1330 M4
Product description
3.3.2.2 Indicators on the front panel
Figure 7: Indicators on the front panel module
Figure 8: Indicators on the front panel on QRL
Pos. Label
Indicator
Status
Description
The server has been highlighted
using ServerView Operations
Manager, iRMC web interface or the
ID button on the front panel for easy
identification.
ID
indicator,
see also
"iRMC-
related
blue on
1
ID
The server has been highlighted for
easy identification using the iRMC
with disabled local VGA output.
flashing
blue
signals" on
RX1330 M4
Operating Manual
31
Product description
Pos. Label
Indicator
Status
Description
No critical event detected (CSS
component).
off
Prefailure event detected (CSS
component).
CSS
indicator
orange
on
2
[CSS]
For HDDs/SSDs, see also
flashing
orange
CSS component failure detected.
No critical event detected (non CSS
component).
off
orange
on
Prefailure event detected (non CSS
component).
Global
Error
indicator,
see also
"iRMC-
related
Non CSS component failure
detected.
Possible causes:
!
3
–
System is out of the specified
temperature range
Defective sensor
CPU error
Error detected by server
management software
flashing
orange
signals" on
–
–
–
HDD/SSD
activity
indicator
flashing
green
4
5
Data access in progress.
off
The server is switched off.
–
–
The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
The server is switched on and
operating normally.
green on
Power-on
indicator
flashing
green
slowly
The BMC firmware is starting up after
the server has been connected to the
mains.
32
OperatingManual
RX1330 M4
Product description
Pos. Label
Indicator
Status
Description
–
The server is switched off and
connected to the mains (standby
mode).
–
The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
green on
AC
connected
indicator
I
After connecting the server to
the mains, it will take about 60
seconds until the server will
enter standby mode and can
be switched on.
6
–
–
The server is switched off and not
connected to the mains.
The server is switched on and
operating normally.
off
RX1330 M4
Operating Manual
33
Product description
iRMC-related status signals
Global error
ID indicator
Description
indicator
A remote connection has been
flashing blue
flashing blue
off
established. Local VGA output has been
disabled during the remote session.
An emergency flash of the iRMC firmware
is in progress.
I
For more information on the
emergency flash of the iRMC
firmware, see the "FUJITSU Server
PRIMERGY RX1330 M4 Upgrade
and Maintenance Manual".
flashing orange
HDD/SSD prefailure detection
Depending on your hardware configuration HDD/SSD prefailure detection will
be supported.
The requirements are:
–
–
iRMC S5 Firmware 1.2 or later
supported OOB RAID system
34
OperatingManual
RX1330 M4
Product description
3.3.2.4 Indicators on the hot-plug HDD/SSD module
Figure 10: Indicators on the hot-plug HDD/SSD module
Pos. Label
Indicator
Status
Description
off
The HDD/SSD is inactive.
Access
1
indicator
green on The HDD/SSD being accessed
off
No HDD/SSD error detected.
An HDD/SSD error has been
detected.
Possible causes:
–
–
–
The drive is defective and
needs replacing.
orange
on
!
Error
indicator
A RAID rebuild process has
failed.
2
The HDD/SSD module has not
been inserted correctly.
HDD/SSD RAID rebuild is in
flashing
orange
slowly
progress. Data is being restored
after replacing a drive that has
been combined into a RAID array.
36
OperatingManual
RX1330 M4
Product description
3.3.3 Indicators on the server rear
3.3.3.1 Indicators on the I/O panel
ID, CSS and Global Error indicators
Figure 11: Indicators on the I/O panel: ID, CSS and Global Error indicators
Pos. Label
Indicator
Status
Description
The server has been highlighted
using ServerView Operations
Manager, iRMC web interface or
the ID button on the front panel for
easy identification.
ID
indicator,
see also
"iRMC-
related
blue on
ID
The server has been highlighted
for easy identification using the
iRMC (AVR) with disabled local
VGA output.
flashing
blue
signals" on
1
No critical event detected (CSS
component).
off
CSS
indicator
orange
on
Prefailure event detected (CSS
component).
[CSS]
flashing
orange
CSS component failure detected.
RX1330 M4
Operating Manual
37
Product description
Pos. Label
Indicator
Status
Description
No critical event detected (non
CSS component).
off
Prefailure event detected (non
CSS component).
Global
Error
orange on
indicator,
see also
"iRMC-
related
Non CSS component failure
detected.
Possible causes:
!
–
System is out of the specified
range
flashing
orange
signals" on
–
–
–
Defective sensor
CPU error
Error detected by server
management software
I
Note on CSS and Global Error indicators on the I/O panel:
If CSS and Global Error indicators are located in the same place on the
I/O panel of the server, also check the indicators on the front panel to
I determine if a CSS or Global Error event has been detected.
For more information on detected errors, see the System Event Log or
use the ServerView Operations Manager or iRMC web interface.
38
OperatingManual
RX1330 M4
Product description
iRMC-related status signals
Global error
ID indicator
Description
indicator
A remote connection has been
flashing blue
flashing blue
off
established. Local VGA output has been
disabled during the remote session.
An emergency flash of the iRMC firmware
is in progress.
I
For more information on the
emergency flash of the iRMC
firmware, see the "FUJITSU Server
PRIMERGY RX1330 M4 Upgrade
and Maintenance Manual".
flashing orange
RX1330 M4
Operating Manual
39
Product description
LAN indicators
Figure 12: LAN indicators
Pos. Indicator
Status
green on
off
Description
A LAN connection has been
established.
LAN
1
2
link/transfer
indicator
LAN is not connected.
flashing
green
LAN data transfer is in progress.
yellow on
Data traffic at a transfer rate of 1 Gbit/s.
Data traffic at a transfer rate of
100 Mbit/s.
LAN speed
indicator
green on
Data traffic at a transfer rate of
10 Mbit/s.
off
40
OperatingManual
RX1330 M4
Product description
3.3.3.2 Indicator on hot-plug PSU
0
Figure 13: Indicator on hot-plug PSU
Pos. Indicator
Status
Description
flashing
green
The server is switched off, but mains
voltage is present (standby mode).
The server is switched on and operating
properly.
green on
An overload has been detected. The
PSU is still running, but failure might be
imminent.
flashing
orange
PSU status
indicator
1
An PSU failure has been detected.
Possible causes:
orange on
–
–
–
Over/under voltage
Overheating
Fan failure
RX1330 M4
Operating Manual
41
Product description
3.3.3.3 Indicator on FJBU
Figure 14: Indicator on FJBU
Pos. Indicator
Status
Description
flashing
green
The battery unit is charging.
flashing
green
slowly
The battery unit is discharging.
The battery unit is fully charged.
FJBU status
indicator
green on
1
A battery unit failure has been detected.
Possible causes:
flashing
orange
–
–
Capacity failure
Overheating
orange on A general battery failure has occurred.
42
OperatingManual
RX1330 M4
4
Important information
In this chapter you will find essential information regarding safety when working
on your server.
I
Depending on your server or the installed options some information is not
V valid for your server.
CAUTION!
Before installing and starting up a server, please observe the safety
instructions listed in the following section. This will help you to avoid
making serious errors that could impair your health, damage the server
and endanger the data base.
4.1
Safety instructions
I
The following safety instructions are also provided in the manual "Safety
Notes and Regulations" or " 安全上のご注意 ".
This server meets the relevant safety regulations for IT equipment. If you have
any questions about whether you can install the server in the intended
environment, please contact your sales outlet or our customer service team.
●
●
●
●
The actions described in this manual shall be performed by technical
specialists. A technical specialist is a person who is trained to install the
server including hardware and software.
Repairs to the server that do not relate to CSS failures shall be performed
by service personnel. Please note that unauthorized interference with the
server will void the warranty and exempt the manufacturer from all liability.
Any failure to observe the guidelines in this manual, and any improper
repairs could expose the user to risks (electric shock, energy hazards, fire
hazards) or damage the equipment.
Only valid for non hot-plug components
Before installing/removing internal components to/from the server, turn off
the server, all peripheral devices, and any other connected devices. Also
unplug all power cords from the power outlet. Failure to do so can cause
electric shock or damage.
RX1330 M4
Operating Manual
43
Important information
Before starting up
●
During installation and before operating the server, observe the instructions
on environmental conditions for your server.
●
If the server is brought in from a cold environment, condensation may form
both inside and on the outside of the server.
Wait until the server has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the server if this
requirement is not observed.
●
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Installation and operation
●
This server should not be operated in ambient temperatures above 35 °C.
For servers with Advanced Thermal Design the ambient temperature can
increase to 40 °C or 45 °C.
●
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
●
The server automatically adjusts itself to a mains voltage, see the type label
of your server. Ensure that the local mains voltage lies within these limits.
This server must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution server with
tested and approved power cords.
●
●
●
Ensure that the server is connected to a properly grounded power outlet
close to the server.
Ensure that the power sockets on the server and the properly grounded
power outlets are easily accessible.
The On/Off button or the main power switch (if present) does not isolate the
server from the mains power supply. In case of repair or servicing disconnect
the server completely from the mains power supply, unplug all power plugs
from the properly grounded power outlets.
44
OperatingManual
RX1330 M4
Important information
●
●
Always connect the server and the attached peripheral devices to the same
power circuit. Otherwise you run the risk of losing data if, for example, the
server is still running but a peripheral device (e.g. memory subsystem) fails
during a power outage.
The adequately shielded data cables must be used.
All data and signal cables must have sufficient shielding. The use of cable
type S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission
of interference and/or reduced fault-tolerance of the device.
●
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
Route the cables in such a way that they do not create a potential hazard
(ensure that no-one can trip over them) and that they cannot be damaged.
When connecting the server, see the relevant instructions in this manual.
●
●
●
Never connect or disconnect data transmission lines during a storm (risk of
lightning hazard).
Ensure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside
the server (risk of electric shock, short circuit).
In emergencies (e.g. damaged casing, controls or cables, penetration of
liquids or foreign bodies), contact the server administrator or your customer
service team. Only disconnect the server from the mains power supply if
there is no risk of harming yourself.
●
●
Proper operation of the server (in accordance with IEC 60950-1 resp.
EN 60950-1) is only ensured if the server is completely assembled and the
rear covers for the installation slots have been fitted (electric shock, cooling,
fire protection, interference suppression).
Only install server expansions that satisfy the requirements and rules
governing safety and electromagnetic compatibility and those relating to
telecommunication terminals. If you install other expansions, they may
damage the server or violate the safety regulations. Information on which
server expansions are approved for installation can be obtained from our
customer service center or your sales outlet.
●
The components marked with a warning notice (e.g. lightning symbol) may
only be opened, removed or exchanged by authorized, qualified personnel.
Exception: CSS components can be replaced.
RX1330 M4
Operating Manual
45
Important information
●
●
The warranty is void if the server is damaged during installation or
replacement of server expansions.
Only set screen resolutions and refresh rates that are specified in the
operating manual for the monitor. Otherwise, you may damage your monitor.
If you are in any doubt, contact your sales outlet or customer service center.
●
Only valid for non hot-plug components
Before installing/removing internal components to/from the server, turn off
the server, all peripheral devices, and any other connected devices. Also
unplug all power cords from the power outlet. Failure to do so can cause
electric shock or damage.
Internal devices remain hot after shutdown. Wait for a while after shutdown
before installing or removing internal options.
●
●
Do not damage or modify internal cables or internal devices. Doing so may
cause a server failure, fire, or electric shock and will void the warranty and
exempt the manufacturer from all liability.
The circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. To ensure reliable protection, you must
wear an earthing band on your wrist when working with this type of module
and connect it to an unpainted, conducting metal part of the server.
●
●
Do not touch the circuitry on boards or soldered parts. Hold the metallic
areas or the edges of the circuit boards.
Install the screw removed during installation/detaching internal options in
former position. To use a screw of the different kind can cause a breakdown
of equipment.
●
The procedure of installation on this notes might change depending on a
configuration of option.
Batteries
●
Incorrect replacement of batteries may lead to a risk of explosion. The
batteries may only be replaced with identical batteries or with a type
recommended by the manufacturer.
●
Do not throw batteries into the trash can.
Batteries must be disposed of in accordance with local regulations
concerning special waste.
●
Ensure that you insert the battery the right way round.
46
OperatingManual
RX1330 M4
Important information
●
●
●
The battery used in this server may present a fire or chemical burn hazard if
mistreated. Do not disassemble, heat about 100 °C (212F), or incinerate the
battery.
Replace the lithium battery on the system board in accordance with the
instructions in the corresponding Upgrade and Maintenance Manual,
chapter "System board and components" > "CMOS battery".
All batteries containing pollutants are marked with a symbol (a crossed-out
garbage can). In addition, the marking is provided with the chemical symbol
of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium
Hg Mercury
Pb Lead
Working with optical disk drives (ODDs) and media
When working with ODDs, these instructions must be followed.
V
CAUTION!
●
●
Only use CDs/DVDs/BDs that are in perfect condition, in order to
prevent data loss, equipment damage and injury.
Check each CD/DVD/BD for damage, cracks, breakages etc. before
inserting it in the drive.
Note that any additional labels applied may change the mechanical
properties of a CD/DVD/BD and cause imbalance and vibrations.
Damaged and imbalanced CDs/DVDs/BDs can break at high drive
speeds (data loss).
Under certain circumstances, sharp CD/DVD/BD fragments can
pierce the cover of the ODD (equipment damage) and can fly out of
the drive (danger of injury, particularly to uncovered body parts such
as the face or neck).
●
High humidity and airborne dust levels are to be avoided. Electric
shocks and/or server failures may be caused by liquids such as
water, or metallic items, such as paper clips, entering a drive.
●
●
Shocks and vibrations are also to be avoided.
Do not insert any objects other than the specified CDs/DVDs/BDs.
RX1330 M4
Operating Manual
47
Important information
●
Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray
roughly.
●
●
●
Do not disassemble the ODD.
Before use, clean the ODD tray using a soft, dry cloth.
As a precaution, remove disks from the ODD when the drive is not to
be used for a long time. Keep the ODD tray closed to prevent foreign
matter, such as dust, from entering the ODD.
●
●
Hold CDs/DVDs/BDs by their edges to avoid contact with the disk
surface.
Do not contaminate the CD/DVD/BD surface with fingerprints, oil,
dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to
the edge. Do not use benzene, thinners, water, record sprays,
antistatic agents, or silicone-impregnated cloth.
●
●
●
●
●
Be careful not to damage the CD/DVD/BD surface.
Keep the CDs/DVDs/BDs away from heat sources.
Do not bend or place heavy objects on CDs/DVDs/BDs.
Do not write with ballpoint pen or pencil on the label (printed) side.
Do not attach stickers or similar to the label side. Doing so may cause
rotational eccentricity and abnormal vibrations.
●
When a CD/DVD/BD is moved from a cold place to a warm place,
moisture condensation on the CD/DVD/BD surface can cause data
read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth
then let it air dry. Do not dry the CD/DVD/BD using devices such as a
hair dryer.
●
●
To avoid dust, damage, and deformation, keep the CD/DVD/BD in its
case whenever it is not in use.
Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to
prolonged direct sunlight or near heating appliances are to be
avoided.
I
You can prevent damage from the ODD and the CDs/DVDs/BDs, as well
as premature wear of the disks, by observing the following suggestions:
–
–
Only insert disks in the drive when needed and remove them after
use.
Store the disks in suitable sleeves.
48
OperatingManual
RX1330 M4
Important information
–
Protect the disks from exposure to heat and direct sunlight.
Laser information
The ODD complies with IEC 60825-1 laser class 1.
V
CAUTION!
The ODD contains a light-emitting diode (LED), which under certain
circumstances produces a laser beam stronger than laser class 1.
Looking directly at this beam is dangerous.
Never remove parts of the ODD casing!
Modules with Electrostatic-Sensitive Devices (ESD modules)
ESD modules are identified by the following sticker:
Figure 15: ESD label
I
The ESD label can be different.
When you handle ESD modules, you must always observe the following points:
●
Switch off the server and remove the power plugs from the power outlets
before installing or removing ESD modules.
●
The circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. To ensure reliable protection, you must
wear an earthing band on your wrist when working with ESD modules and
connect it to an unpainted, conducting metal part of the server.
●
●
Any devices or tools that are used must be free of electrostatic charge.
Wear a suitable grounding cable that connects you to the external chassis
of the server.
●
Always hold ESD modules at the edges or at the points marked green (touch
points).
RX1330 M4
Operating Manual
49
Important information
●
●
Do not touch any connectors or conduction paths on an ESD module.
Place all the components on a pad which is free of electrostatic charge.
I
For a detailed description of how to handle ESD modules, see the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).
Transporting the server
V
CAUTION!
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Do not unpack the server until it is at its installation location.
If you need to lift or transport the server, ask other people to help you.
Never lift or carry the server by the handles or the Quick Release Levers
(QRLs) on the front panel.
Notes on installing the server in the rack
V
CAUTION!
●
For safety reasons, at least 2 people are required to install the server
in the rack because of its weight and size.
(For Japan, see " 安全上のご注意 ".)
●
●
Never lift the server into the rack using the QRLs on the front panel.
When connecting and disconnecting cables, observe the relevant
instructions in the "Important Information" chapter of the technical
manual for the corresponding rack. The technical manual is supplied
with the corresponding rack.
●
●
When installing the rack, ensure that the anti-tilt mechanism is
correctly fitted.
Do not extend more than one server out of the rack simultaneously
even if the tilt protection is in place. If several servers are
simultaneously extended from the rack, there is a risk that the rack
could tip over. See the safety information of the rack and the warning
label.
50
OperatingManual
RX1330 M4
Important information
●
●
If the server/rack is intended for permanent connection to the mains
only an authorized specialist (electrician) is allowed to work.
Please follow the regulation of each country.
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 type connector, the
power supply's fuse protection must comply with the requirements for
non-industrial power supply networks for the type A connector.
Other important information
●
During cleaning, observe the instructions in the corresponding Operating
Manual chapter "Starting up and operation" > "Cleaning the server".
●
Keep all manuals close to the server. All documentation must be included if
the equipment is passed on to a third party.
4.2
ENERGY STAR
Products that have been certified compliant with ENERGY STAR
and labelled are in full compliance with the specification at
shipping. Note that energy consumption can be affected by
software that is installed or any changes that are made to the
hardware configuration or BIOS or energy options subsequently.
In such cases, the properties guaranteed by ENERGY STAR can
no longer be assured.
The "ServerView Operations Manager" user guide contains
instructions for reading out measurement values, including those
relating to current energy consumption and air temperatures.
Either the Performance Monitor or the Task Manager can be
used to read out CPU utilization levels.
RX1330 M4
Operating Manual
51
Important information
4.3
CE conformity
The system complies with the requirements of European
Regulations. Find the CE declaration on certificate portal:
To open the CE declaration applicable for your system, proceed
as follows:
Ê
Ê
Ê
Ê
Select Industry Standard Servers.
Select your model, e.g. Rack server.
Select your system, e.g. PRIMERGY RX2530 M1.
Select CE Cert <your system>.
V
CAUTION!
This is a Class A product. In a domestic environment this
product may cause RF interference, in which case the
user may be required to take adequate measures.
52
OperatingManual
RX1330 M4
Important information
4.4
FCC Class A Compliance Statement
If there is an FCC statement on the device, it applies to the products covered in
this manual, unless otherwise specified herein. The statement for other
products will appear in the accompanying documentation.
NOTE:
This equipment has been tested and found to comply with the limits for a
"Class A" digital device, pursuant to Part 15 of the FCC rules and meets all
requirements of the Canadian Interference-Causing Equipment Standard
ICES-003 for digital apparatus. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in strict accordance with the instructions, may cause harmful
interference to radio communications. However, there is no warranty that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
●
●
●
Reorient or relocate the receiving antenna.
Increase the separation between equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
●
Consult the dealer or an experienced radio/TV technician for help.
Fujitsu is not responsible for any radio or television interference caused by
unauthorized modifications of this equipment or the substitution or attachment
of connecting cables and equipment other than those specified by Fujitsu. The
correction of interferences caused by such unauthorized modification,
substitution or attachment will be the responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to
any and all optional peripheral or host devices. Failure to do so may violate FCC
and ICES rules.
RX1330 M4
Operating Manual
53
Important information
4.5
Environmental protection
Environmentally-friendly product design and development
This product has been designed in accordance with the Fujitsu standard for
"environmentally friendly product design and development". This means that
key factors such as durability, selection and labeling of materials, emissions,
packaging, ease of dismantling and recycling have been taken into account.
This saves resources and thus reduces the harm done to the environment.
More information can be found at:
For Japan:
Energy-saving information
Devices that do not need to be constantly switched on should be switched off
until they are needed as well as during long breaks and after completion of work.
Packaging information
This packaging information does not apply in Japan and APAC.
Do not throw away the packaging. You may need it later for transporting the
server. If possible, the equipment should only be transported in its original
packaging.
Information on handling consumables
Please dispose of printer consumables and batteries in accordance with the
applicable national regulations.
In accordance with EU directives, batteries must not be disposed of with
unsorted domestic waste. They can be returned free of charge to the
manufacturer, dealer or an authorized agent for recycling or disposal.
All batteries containing pollutants are marked with a symbol (a crossed-out
garbage can). They are also marked with the chemical symbol for the heavy
metal that causes them to be categorized as containing pollutants:
Cd Cadmium
Hg Mercury
Pb Lead
54
OperatingManual
RX1330 M4
Important information
Labels on plastic casing parts
Please avoid sticking your own labels on plastic parts wherever possible, since
this makes it difficult to recycle them.
Returns, recycling and disposal
Please handle returns, recycling and disposal in accordance with local
regulations.
The device must not be disposed of with domestic waste. This
device is labeled in compliance with European directive
2012/19/EU on waste electrical and electronic equipment (WEEE).
This directive sets the framework for returning and recycling used
equipment and is valid across the EU. When returning your used
device, please use the return and collection systems available to
you.
More information can be found at:
Details regarding the return and recycling of devices and consumables within
Europe can also be found in the "Returning used devices" manual, via your local
Fujitsu branch, or at:
RX1330 M4
Operating Manual
55
Important information
56
OperatingManual
RX1330 M4
5
Starting up
V
CAUTION!
●
Follow the safety instructions in chapter "Important information" on
●
Do not expose the server to extreme environmental conditions (see
humidity and heat.
●
Ensure that the server is acclimatized for the time indicated in this
table before putting it into operation.
Temperature difference (°C) Minimum acclimatization time
(hours)
5
3
5
10
15
7
20
8
25
30
9
10
Table 2: Acclimatization time
to the difference between the operating environment temperature and
the temperature to which the server was exposed previously (outside,
transport or storage temperature).
RX1330 M4
Operating Manual
57
Starting up
5.1
Installation steps, overview
Ê
First of all, carefully read the safety instructions in "Important information" on
page 43 and following.
Ê
Ê
Transport the server to the place where you want to set it up.
Unpack the system, check the contents of the package for visible transport
damage and check whether the items delivered correspond to the details on
Ê
Ê
Ê
Ê
Ensure that you have all necessary manuals, see "Documentation overview"
on page 13; print out the PDF files if required.
Components that have been ordered additionally may be delivered loose
with the server. For installing, see the original component documentation.
Install the server in the rack, see section "Installing the server in the rack" on
Ê
Ê
Ê
Ê
Connect the server to the mains, see section "Connecting the power cord"
If applicable, install the HDD/SSD modules, see "Installing HDD/SSD
If applicable, install a second PSU, see "Installing a second PSU" on
Familiarize yourself with the controls and indicators on the front and rear of
58
OperatingManual
RX1330 M4
Starting up
Ê
Configure the server and install the desired operating system and
applications. The following options are available:
Installation with ServerView Installation Manager
–
–
Local configuration and installation, see section "Configuring the server
Remote installation, see section "Configuring the server with ServerView
I
For more information on installing the server (remote or local), see
the "ServerView Installation Manager" user guide at
ServerView Suite - Server Installation and Deployment.
Installation without ServerView Installation Manager
–
Local configuration and installation, see section "Configuring the server
RX1330 M4
Operating Manual
59
Starting up
5.2
Unpacking the server
V
CAUTION!
The server must always be lifted or carried by at least two people.
(For Japan, see " 安全上のご注意 ")
Do not unpack the server until it is at its installation location.
Ê
Ê
Transport the server to the place where you want to set it up.
Unpack all individual parts.
Keep the original packaging in case you want to transport the server again
(does not apply to Japan).
Ê
Ê
Check the delivery for any damage during transport.
Check whether the items delivered match the details on the delivery note.
The product name and serial number of the product can be found on the ID card
Ê
Notify your supplier immediately should you discover that the items
delivered do not correspond to the delivery note.
Ê
Remove all scratching protection foils from the front panel, HDD/SSD
frames, Fujitsu and PRIMERGY logo, VGA dummy and ODD dummy in
case they are still sticked to the server system.
60
OperatingManual
RX1330 M4
Starting up
5.3
Installing the server in the rack
V
CAUTION!
●
Please observe the safety information and notes on rack mounting in
●
●
At least two people are needed to install / remove the server in the
rack. (For Japan, see " 安全上のご注意 ".)
Do not extend more than one unit out of the rack simultaneously even
if the tilt protection is in place. If several units are simultaneously
extended out of the rack, there is a risk that the rack could tip over.
Fujitsu rack systems
The rack systems from Fujitsu support the installation of PRIMERGY servers:
–
–
–
–
–
PRIMECENTER rack
PRIMECENTER M1 rack
DataCenter rack
19-inch standard rack (for Japan)
19-inch slim rack (for Japan)
I
For information on mounting the server in the rack, see the "Mounting
Instructions" provided with the Rack Mounting Kit. For more information,
see the manual of your rack system.
I For Japan, see also to the "Rack system structure guide".
Online documentation for rack installation can be found on:
For Japan:
RX1330 M4
Operating Manual
61
Starting up
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack (not valid
for Japan).
The main features of Fujitsu rack systems are as follows:
–
–
rail systems that can be mounted without tools
support systems having a linear alignment feature to ensure that they can
be adjusted to different rack depths
Asymmetrical PRIMECENTER rack and DataCenter rack provide an enhanced
cable management in the lateral rack area.
3rd party racks
I
Installation in most current rack systems from other manufacturers
(3rd party racks) is also supported. For details please contact your sales
representative.
–
Wire the server. Read the information in section "Connecting devices to the
–
Connect the system to the mains, see section "Connecting the power cord"
62
OperatingManual
RX1330 M4
Starting up
5.3.1 Installing the server in the rack
V
CAUTION!
At least two people are needed to position the server on the rack rails.
(For Japan, see " 安全上のご注意 ".)
For configurations below 32 kg:
At least two people are needed to lift the server
into the rack cabinet.
For configurations below 55 kg:
At least three people are needed to lift the server
into the rack cabinet.
For configurations above 55 kg:
At least four people are needed to lift the server
into the rack cabinet.
Additionally, a lifter is required in the following cases:
–
–
The server weighs more than 50 kg.
The server weighs more than 21 kg and is to be installed above the
height of 25 U.
When using a lifter, this installation procedure needs to be carried out by
maintenance personnel.
RX1330 M4
Operating Manual
63
Starting up
ቤ
ባ
ባ
ቢ
ቢ
ብ
Figure 16: Inserting the server into the rack rails
Ê
Fully extend the rack rails until they lock in place (1).
I
The rack rails must click into place so that they can no longer be
moved.
Ê
Ê
At a slight angle, lower the server onto the rear mounting point on the rack
rails (2).
Fold down the server, while pressing the rail to the server side (3). Ensure
that all six rack mounting bolts are properly seated in the mounting points on
the rack rails and that the locking bars engage (4).
64
OperatingManual
RX1330 M4
Starting up
ባ
ባ
ቢ
ቤ
Figure 17: Sliding the server into the rack
Ê
Ê
Release the locking mechanism of both rails (1).
Push the server as far as it will go into the rack (2) until the quick-release
levers engage (3).
V
CAUTION!
Be careful with your fingers. You can pinch them when the quick-
release levers change to the release position.
Ê
Reconnect all cables except the power cord to the server rear.
RX1330 M4
Operating Manual
65
Starting up
5.4
Connecting cables
5.4.1 Notes on connecting/disconnecting cables
V
CAUTION!
Always read the documentation supplied with the device you wish to
connect.
Never connect, or disconnect cables during a thunderstorm.
Never pull on a cable when disconnecting it. Always take hold of the
cable by the plug.
Follow the sequence described below to connect or disconnect external
devices to or from the server:
Ensure that you wait for 10 seconds or more after shutdown before
turning the server on.
Connecting cables
Ê
Ê
Ê
Ê
Ê
Switch off the server and equipment switches.
Disconnect all power cords from the properly grounded power outlets.
Connect all cables to the server and peripherals.
Connect all data communication cables into the utility sockets.
Connect all power cords into the properly grounded power outlets.
Disconnecting cables
Ê
Ê
Ê
Ê
Switch off the server and equipment switches.
Disconnect all power cords from the properly grounded power outlets.
Disconnect all data communication cables from the utility sockets.
Disconnect the relevant cables from the server and all the peripherals.
I
For connecting or disconnecting LAN cables, the server does not need
to be powered off. To avoid loss of data teaming function has to be
enabled.
66
OperatingManual
RX1330 M4
Starting up
Information for ensuring electromagnetic compatibility
All data and signal cables must have sufficient shielding. The use of cable type
S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission of
interference and/or reduced fault-tolerance of the device.
5.4.2 Connecting devices to the server
The connectors for external devices are on the front and rear of the server, see
I
For a remote installation using the ServerView Installation Manger a LAN
I connection is necessary.
Some of the devices that can be connected may require special
software, e.g. drivers (see the documentation for the connected device).
Connecting the keyboard, mouse and monitor
Ê
Ê
Connect the keyboard and mouse to the USB connectors of the server.
Connect the monitor to one of the two video connectors at the front or rear.
I
The front video connector is designed for maintenance issues. If you
connect a monitor to the video connector at the front, the video
connector at the rear is deactivated. A monitor connected to the front
must have at least the same resolution as the monitor connected to
the rear. A console bypass is not possible via the video connector at
I the front.
If a separate graphics card is installed in a slot, the graphic controller
on the system board is automatically deactivated. The corresponding
video connector can not be used. Connect the video cable of the
monitor to the video connector of the graphics card.
Ê
Connect the power cord of the monitor to a power outlet of the rack socket
strip.
I
The rated current for the monitor is indicated on the technical data label
on the monitor or in the operating manual for the monitor.
RX1330 M4
Operating Manual
67
Starting up
5.4.3 Connecting the power cord
In its basic configuration the server has a permanently installed PSU or a hot-
plug PSU. Besides the hot-plug PSU, a second hot-plug PSU can be installed
optionally to serve as a redundant power supply. If one PSU fails, the second
PSU in the redundant configuration ensures operation can continue
uninterrupted.
V
CAUTION!
The server is automatically set to a mains voltage in the range 100 V -
240 V. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Ê
Ê
Connect the power cord to the PSU.
Connect the mains connector to an outlet on the socket strip of the rack.
I
I
It will take about 60 seconds until the server can be switched on.
For more information, see the technical manual for the rack.
68
OperatingManual
RX1330 M4
Starting up
5.4.3.1 Using cable ties (standard PSU)
You can secure the power cord using a cable tie to ensure that the insulated
connector cannot be disconnected from the server accidentally. The cable tie is
included in the accessories pack that is delivered together with the server.
ባ
ቢ
Figure 18: Using cable ties
Ê
Ê
Thread the cable tie through the eye (1).
Pull the cable tie tight to secure the power cord.
The insulated connector cannot now be disconnected from the server
accidentally.
You can loosen the cable tie by opening the small locking lever (2).
RX1330 M4
Operating Manual
69
Starting up
5.4.3.2 Using the cable clamp
You can secure the power cord with a cable clamp to ensure that the power cord
cannot be disconnected from the server by mistake. The cable clamp is
included in the accessories pack that is delivered together with the server.
Figure 19: Using cable clamps
Ê
Ê
Ê
Pull the cable clamp up (1).
Thread the power cord through the cable clamp (2).
Press the cable clamp down until it engages to secure the cable (3).
70
OperatingManual
RX1330 M4
Starting up
5.5
Switching on the server for the first time
V
CAUTION!
●
If nothing appears on the screen but flickering stripes after switching
on the server, switch off the server immediately (see chapter
●
The On/Off button does not disconnect the server from the mains. To
completely disconnect it from the mains, remove the power cords
from the PSUs.
●
●
Do not move, strike, or shake the server when it is switched on. This
can damage the HDD/SSD in the server and cause data loss.
Switch the server on when the temperature is in the specified
temperature range. For more information on the operating
the server out of the specified temperature range, the server may
operate improperly and data loss may occur. Furthermore, Fujitsu
cannot be held responsible for any related damage, malfunction, or
loss of data, etc.
●
●
Ensure that you wait for 10 seconds or more after power off before
switching on the server again.
After connecting all power cords, wait at least 10 seconds before
pressing the On/Off button.
Switching the server on
The AC connected indicator lights up green (standby mode) when the server is
connected to the mains.
I
It will take about 60 seconds until the server can be switched on.
–
Starting up
For Japan, see " はじめにお読み く だ さい ".
Ê
Ê
Press the On/Off button.
Configure your server and install the operating system, see section
RX1330 M4
Operating Manual
71
Starting up
5.6
Configuring the server with ServerView
Installation Manager
I
Ensure that the power saving functions are disabled in the Power menu
of the BIOS setup during operation.
Advantages of the ServerView Installation Manager
–
–
–
Wizard-assisted configuration of your server hardware and disk arrays.
Wizard-assisted installation of all leading server operating systems.
Wizard-assisted creation of configuration files for unattended installation of
several PRIMERGY servers with identical hardware configurations.
–
Installation of drivers and additional software.
I
The software that can be installed depends on the hardware
configuration of your server. This configuration is detected automatically.
5.6.1 Configuring the server and installing the operating
system
I
When using the ServerView Installation Manager you can configure the
I onboard controller either before or during installation.
Descriptions of operating systems not covered in the RAID controller
manual are provided in the corresponding readme files under:
For Japan:
72
OperatingManual
RX1330 M4
Starting up
5.6.1.1 Configuring the controllers
Ê
Ê
Configure the RAID controllers using the ServerView RAID Manager.
If applicable, configure the onboard SATA controller, see "Notes on
Ê
If applicable, configure the SAS/SATA RAID controller with MegaRAID
5.6.1.2 Installing the operating system
I
For more information on installing the server, see the
"ServerView Installation Manager" user guide at
ServerView Suite - Server Installation and Deployment.
Ê
Ê
Open this manual.
For the remote or local installation, follow the instruction in this manual and
on the screen.
Ê
Configure the settings for the general system behavior of the server using
the Server Configuration Manager.
RX1330 M4
Operating Manual
73
Starting up
5.7
Configuring the server without ServerView
Installation Manager
5.7.1 Configuring the server and installing the operating
system
5.7.1.1 Configuring the onboard SAS/SATA controller
Ê
If applicable, configure the onboard SATA controller, see "Notes on
Ê
If applicable, configure the SAS/SATA RAID controller with MegaRAID
5.7.1.2 Installing the operating system
Ê
Ê
Ê
Insert the DVD for the operating system you want to install.
Reboot the server.
Follow the instructions on screen and in the manual for the operating
system.
74
OperatingManual
RX1330 M4
Starting up
5.8
Notes on configuring controllers
I
Ensure that the power saving functions are disabled in the Power menu
I of the BIOS setup during operation.
Descriptions of operating systems not covered in the controller manual
are provided in the corresponding readme under:
For Japan:
5.8.1 Notes on onboard SATA controllers
I
The controller has its own configuration utility. For more information, see
the “Embedded MegaRAID Software User’s Guide” (on the Fujitsu
manuals server under x86 Servers - Expansion Cards - Storage
I Adapters - LSI Configuration Software).
In the BIOS the onboard SATA controller can be configured as RAID
(default) or non-RAID.
5.8.2 Notes on SAS/SATA RAID controllers
I
A separate utility is available to the controller for MegaRAID
configuration. For more information, see the "SAS Software User’s
Guide" (on the Fujitsu manuals server under x86 Servers - Expansion
Cards - Storage Adapters - LSI Configuration Software).
More information on modular RAID controllers is provided in the
"Modular RAID Controller Installation Guide" (on the Fujitsu manuals
server under x86 Servers - Expansion Cards - Storage Adapters - LSI
SAS / SCSI RAID Controllers).
RX1330 M4
Operating Manual
75
Starting up
5.9
Note on operating system
Open the Windows operating system / Restoring the preinstalled
environment
For the procedure to open the Windows operation system or to restore the
preinstalled environment, see the manuals on the Fujitsu manual download site
attached manuals.
Linux operating system support
About the Fujitsu Support Pack for Linux (FJ-LSP)
The FJ-LSP can only be used from customers who have an contracted support
as a tool to create an Fujitsu recommended Linux support environment.
The FJ-LSP can be downloaded from the Fujitsu SupportDesk subscriber site
The FJ-LSP have to be used with the application wizard of the ServerView
Installation Manager.
76
OperatingManual
RX1330 M4
6
Operation
V
CAUTION!
Follow the safety instructions in chapter "Important information" on
6.1
Switching the server on and off
V
CAUTION!
●
If nothing appears on the screen but flickering stripes after switching
on the server, switch off the server immediately (see chapter
●
The On/Off button does not disconnect the server from the mains. To
completely disconnect it from the mains, remove the power cords
from the PSUs.
●
●
Do not move, strike, or shake the server when it is switched on. This
can damage the HDD/SSD in the server and cause data loss.
Switch the server on when the temperature is in the specified
temperature range. For more information on the operating
the server out of the specified temperature range, the server may
operate improperly and data loss may occur. Furthermore, Fujitsu
cannot be held responsible for any related damage, malfunction, or
loss of data, etc.
●
●
Ensure that you wait for 10 seconds or more after power off before
switching on the server again.
After connecting all power cords, wait at least 10 seconds before
pressing the On/Off button.
RX1330 M4
Operating Manual
77
Operation
Switching the server on
The AC connected indicator lights up green (standby mode) when the server is
connected to the mains.
I
It will take about 60 seconds until the server can be switched on.
Ê
Press the On/Off button.
The server is switched on, performs a system test and boots the operating
system.
I
In the case of configurations with a large memory size, the boot
process may be prolonged and the screen may remain dark for
several minutes.
Switching the server off
The power-on indicator lights up green.
Ê
Shut down the operating system properly.
The server is switched off automatically and enters standby mode. The AC
connected indicator lights up green.
I
If the operating system does not turn off the server automatically, press
the On/Off button for at least four seconds and/or send a corresponding
V control signal for power button override.
CAUTION!
There is a risk that data may be lost.
Other On/Off options
Besides the On/Off button, the server can be switched on and off in the following
ways:
–
–
Timer-controlled turn-on/off
Using the ServerView Operations Manager or iRMC, you can configure that
the server is turned on/off controlled by an internal timer.
Ring indicator
The server is turned on by an internal or external modem.
78
OperatingManual
RX1330 M4
Operation
–
–
Wake up On LAN (WOL)
The server is turned on by a command via the LAN (Magic Packet™).
After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC).
–
Power button override
The system can be switched off (hard power off) by keeping the On/Off
button (approximately 4 - 5 seconds).
V
CAUTION!
There is a risk that data may be lost.
–
iRMC
iRMC offers various options for switching the server on and off, e.g. via the
System power button on the Global icons of the iRMC web interface.
V
CAUTION when switching off the power!
The operation of the power switch can be specified as "Do Nothing",
"Stand by", "Hibernate", and "Shutdown" depending on the OS settings.
The default is "Shutdown".
On this server, functions corresponding to "Stand by" and "Hibernate" are
supported as BIOS and hardware functions. However, some drivers and
software installed in the server do not support these functions. For this
reason, functions corresponding to "Stand by" and "Hibernate" are
unavailable on this server. When the operating mode is set to "Stand by"
or "Hibernate", the system may operate improperly or HDD/SSD data
may be corrupted.
For more information about operating mode settings, see the manual
supplied with the OS.
RX1330 M4
Operating Manual
79
Operation
6.2
Installing HDD/SSD modules
6.2.1 Installing 2.5-inch HDD/SSD modules
6.2.1.1 Removing a 2.5-inch HDD/SSD dummy module
Figure 20: Removing a 2.5-inch HDD/SSD dummy module
Ê
Press both tabs together (1) and pull the dummy module out of its bay (2).
V
CAUTION!
Keep the dummy module for future use.
Always replace dummy modules into unused HDD/SSD bays to comply
with applicable EMC regulations and satisfy cooling requirements.
80
OperatingManual
RX1330 M4
Operation
6.2.1.2 Installing a 2.5-inch HDD/SSD module
Figure 21: Opening the 2.5-inch HDD/SSD module locking lever
Ê
Pinch the green locking clip (1) and open the locking lever (2).
Figure 22: Installing the 2.5-inch HDD/SSD module
Ê
Insert the HDD/SSD module into a drive bay and carefully push back as far
as it will go (1).
Ê
Ê
Close the locking lever to lock the HDD/SSD module in place (2).
When using a RAID array, add the additional HDD/SSD to the RAID array.
I
Configuring the RAID array, see the documentation of the RAID
controller, used in your configuration, see section "Documentation
RX1330 M4
Operating Manual
81
Operation
6.2.2 Installing 3.5-inch HDD modules
6.2.2.1 Removing a 3.5-inch HDD dummy module
Figure 23: Removing a 3.5-inch dummy module
Ê
Press both tabs together (1) and pull the dummy module out of its bay (2).
V
CAUTION!
Keep the dummy module for future use.
Always replace dummy modules into unused HDD bays to comply with
applicable EMC regulations and satisfy cooling requirements.
6.2.2.2 Installing a 3.5-inch HDD module
Figure 24: Opening the 3.5-inch HDD module locking lever
Ê
Pinch the green locking clip (1) and open the locking lever (2).
82
OperatingManual
RX1330 M4
Operation
Figure 25: Installing the 3.5-inch HDD module
Ê
Insert the HDD module into a drive bay and carefully push back as far as it
will go (1).
Ê
Ê
Close the locking lever to lock the HDD module in place (2).
When using a RAID array, add the additional HDD/SSD to the RAID array.
I
Configuring the RAID array, see the documentation of the RAID
controller, used in your configuration, see section "Documentation
RX1330 M4
Operating Manual
83
Operation
6.3
Installing a second PSU
6.3.1 Removing the dummy cover
Figure 26: Removing the PSU dummy cover
Ê
Press in on both release latches (1) and remove the dummy cover (2).
V
CAUTION!
Keep the dummy cover for future use. If a PSU is removed and not
immediately replaced by a new one, a dummy cover must be installed in
the bay again to comply with applicable EMC regulations and satisfy
cooling requirements.
6.3.2 Installing a PSU
Figure 27: Folding up the handle
84
OperatingManual
RX1330 M4
Operation
Ê
Push the handle of the PSU halfway upward in the direction of the arrow.
Figure 28: Installing a PSU
Ê
Push the PSU into its bay (1) as far as it will go until the release latch snaps
in place.
Ê
Fold down the handle on the PSU (2).
I
Ensure that the PSU engages correctly in the bay and is locked in
position. This is the only way to prevent the PSU from sliding out of its
bay and being damaged during transportation.
Figure 29: Installing the cable tie
Ê
Ê
Push the cable tie into the corresponding hole until it clicks in.
If applicable, configure the redundant power supply.
RX1330 M4
Operating Manual
85
Operation
6.4
Cleaning the server
V
CAUTION!
Switch off the server and disconnect the power plugs from the properly
grounded power outlets.
Do not clean any interior parts yourself; leave this job to a service
technician.
Do not use any cleaning agents that contain abrasives or may corrode
plastic.
Ensure that no liquid enters the system. Ensure that the ventilation areas
of the server and the monitor are clear.
Do not use any cleaning sprays (including flammable types). It may
cause a device failure or a fire.
Clean the keyboard and the mouse with a disinfecting cloth.
Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a
cloth that has been moistened in a mild domestic detergent and then carefully
wrung out.
86
OperatingManual
RX1330 M4
7
Troubleshooting and tips
V
CAUTION!
Follow the safety instructions in the "Safety Notes and Regulations"
If a fault occurs, attempt to resolve it using the measures described:
–
–
–
in this chapter,
in the documentation for the connected devices,
in the help systems of the software used.
If you fail to correct the problem, proceed as follows:
Ê
Make a list of the steps performed and the circumstances that led to the fault.
Also make a list of any error messages that were displayed.
Ê
Ê
Switch off the server.
Contact our customer service team.
I
The meaning of the error message is explained in the documentation for
the relevant components and programs, available online at
Power-on indicator remains unlit after you have switched on your device
Cause
Troubleshooting
Power cable
incorrectly connected
Ê
Ensure that the power cable(s) is/are correctly
connected to the server and the grounded power
outlet(s).
Power supply
overloaded
Ê
Ê
Ê
Disconnect the server power plug(s) from the
grounded power outlet(s).
Wait a few minutes before you plug it/them into
the grounded power outlet(s) again.
Switch on your server.
RX1330 M4
Operating Manual
87
Troubleshooting and tips
The system will not boot after installing a new HDD
Cause
Troubleshooting
SAS configuration
incorrect
Ê
Check the settings for the HDDs (SAS Device
Configuration) and the additional settings in the
SAS configuration menu.
Screen remains blank
Cause
Troubleshooting
Monitor is switched off Ê Switch on your monitor.
Screen has gone blank Ê Press any key on the keyboard.
or
Ê
Deactivate screen saver and enter the
appropriate password.
Brightness control is Ê Set the brightness control on the monitor to light.
set to dark
For more information, see the operating manual
supplied with your monitor.
No screen display or display drifts
Cause
Troubleshooting
Wrong horizontal
frequency or resolution
selected
Ê
Find out which horizontal frequency your monitor
screen supports. You will find the horizontal
frequency (also known as line frequency or
horizontal deflection frequency) in the
documentation for your monitor.
Ê
See the documentation for your operating system
or the software for the screen controller for more
information of how to set the correct horizontal
frequency for your monitor, and follow the
procedure accordingly.
88
OperatingManual
RX1330 M4
Troubleshooting and tips
Server switches itself off
Cause
Troubleshooting
Server Management Ê Check the error list of System Event Log in
has detected an error
ServerView Operations Manager or in the iRMC
web interface, and attempt to eliminate the error.
No mouse pointer displayed on screen
Cause
Troubleshooting
Mouse driver not
loaded
Ê
Check whether the mouse driver is properly
installed and is activated when the application
program is started. Detailed information can be
found in the user manuals for the mouse, the
operating system and the application program.
No effect of keyboard or mouse
Cause
Troubleshooting
Typing the keyboard Ê Check to see whether the keyboard and mouse
does not display any
characters, or the
mouse cursor does not
move
are connected properly. If they are not connected
or you replaced them yourself, then connect the
cables to the server.
RX1330 M4
Operating Manual
89
Troubleshooting and tips
Time and/or date is incorrect
Cause
Troubleshooting
Time and date is
incorrect
Ê
Set the correct time and date in the operating
system.
or
Ê
Set the correct time and date in the BIOS Main
menu, using System Date and System Time
respectively.
I
Note that the operating system may affect the
system time. For example, the operating
system time may deviate from the system time
under Linux, and would overwrite the system
time in the default setting on shutdown.
The lithium battery is Ê If the date and time are still wrong after the server
discharged
has been switched off and back on again, replace
the lithium battery (see the "FUJITSU Server
PRIMERGY RX1330 M4 Upgrade and
Maintenance Manual") or contact our customer
service team.
90
OperatingManual
RX1330 M4
Troubleshooting and tips
Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message.
This warning is issued by ServerView when the ambient temperature exceeds
the upper limit of the temperature boundaries. The upper limit is 35°C for
standard server and 40°C or 45°C with Advanced Thermal Design.
Cause
Troubleshooting
The ambient
Ê
Although continued use within the temperature
boundaries poses no problems within itself,
reconsider the surrounding environment
conditions if this log is output or if ServerView
issues this notification.
temperature exceeds
the upper limit of the
temperature
boundaries
Added drive reported as defective
Cause
Troubleshooting
RAID controller is not The drive was probably installed when the system
configured for this
drive
was switched off.
Ê
Reconfigure the RAID controller for the drive
using the corresponding utility. Information is
provided in the documentation for the RAID
controller.
or
Ê
Remove and reinstall the drive while the system is
switched on.
If the HDD/SSD continues to be shown as
defective, then replace it (see the "FUJITSU
Server PRIMERGY RX1330 M4 Server Upgrade
and Maintenance Manual").
RX1330 M4
Operating Manual
91
Troubleshooting and tips
Expansion cards or onboard devices not recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Cause
Troubleshooting
Expansion cards or
onboard devices not
recognized
Ê
Reinstall the drivers for the expansion cards or
onboard devices that are not recognized.
Expansion cards or onboard devices not recognized
Various HDD/SSD error messages may occur when the system is rebooted.
These error messages are caused by modifications in the selected RAID
configuration.
Cause
Troubleshooting
RAID controller
configuration incorrect
Ê
Check and correct the settings for the drives using
the RAID controller configuration program.
I
For more information, see the "Integrated
RAID for SAS User’s Guide" available online
Servers - Expansion Cards - Storage
Adapters - LSI SAS / SCSI RAID Contollers
or in the "Modular RAID Controller Installation
Guide" available online at
Servers - Expansion Cards - Storage
Adapters - LSI SAS / SCSI RAID Contollers.
92
OperatingManual
RX1330 M4
Troubleshooting and tips
ODD cannot read data
Cause
Troubleshooting
ODD cannot read data Ê Check to see whether the CD/DVD/BD is inserted
properly. If the CD/DVD/BD is not inserted,
correctly insert the disk so that the label is facing
up.
Ê
Check to see whether the CD/DVD/BD is not dirty.
If the CD/DVD/BD is dirty, wipe it in a radial way
with a soft, dry cloth.
Ê
Check to see whether the CD/DVD/BD is not
scratched or bent. If scratched or damaged,
replace the CD/DVD/BD.
RX1330 M4
Operating Manual
93
Troubleshooting and tips
94
OperatingManual
RX1330 M4
8
Technical data
This section explains the specifications for the server. The specifications for this
server are liable to be updated without any notice. Please be forewarned.
I
The data sheets for this server contain more technical data. The data
sheets are available online at:
For more information, see the Documents tab under e.g. Rack Servers.
For Japan:
System board
System board type
Chipset
D3675
Intel® C246
Processor (CPU)
CPU quantity and type 1x Intel® Xeon® CPU E21xx or Pentium or Core i3,
up to 95 W, up to 6 cores
Memory modules configuration
Memory slots
Memory type
4
UDIMM (DDR4)
4 GB - 64 GB
Memory capacity
(min. - max.)
Memory protection
Memory notes
ECC
2667 MHz memory modules with 4, 8 or 16 GB
RX1330 M4
Operating Manual
95
Technical data
Interfaces
USB
Rear: 2 x USB 2.0, 2 x USB 3.1 Gen 2
(not on 10x HDD/SSD Front: 2 x USB 3.1 Gen 1
version)
Internal: 1 x USB 3.1 Gen 1
USB
Rear: 2 x USB 2.0, 2 x USB 3.1 Gen 2
(for up to 10
HDDs/SSDs)
Front: 1 x USB 2.0
Internal: 1 x USB 3.1 Gen 1
Graphics (15-pin)
Serial 1 (9-pin)
1 x VGA (rear), 1 x front VGA (optional)
1 x serial RS-232-C, usable for iRMC or system or
shared (optional)
LAN / Ethernet
2 x Intel® i210 Gbit/s Ethernet
Management LAN
(RJ45)
1 x dedicated management LAN port for iRMC
(10/100/1000 Mbit/s). Management LAN traffic can
be switched to shared onboard converged network
adapter.
96
OperatingManual
RX1330 M4
Technical data
Onboard or integrated controllers
RAID controller
PSAS CP400i with "Integrated RAID" (IR)
RAID levels 0 and 1 are supported for internal HDD
configurations.
Modular RAID controller (based on LSI SAS3108)
SAS/SATA HDD/SSD up to 12 Gbit/s SAS, 6 Gbit/s
SATA, 8 ports internal/external
RAID level: 0, 1, 1E, 10, 5, 50, 6, 60
1/2/4 GB cache, optional FBU
Modular RAID controller (based on LSI SAS3508)
SAS/SATA/PCIe HDD/SSD up to 12 Gbit/s SAS,
6 Gbit/s SATA, 8 Gbit/s PCIE, 8 ports internal
RAID level: 0, 1, 1E, 10, 5, 50, 6, 60
2 GB cache, optional FBU
Modular RAID controller (based on LSI SAS3516)
SAS/SATA/PCIe HDD/SSD up to 12 Gbit/s SAS,
6 Gbit/s SATA, 8 Gbit/s PCIE, 16 ports internal /
8 ports external
RAID level: 0, 1, 1E, 10, 5, 50, 6, 60
4/8 GB cache, optional FBU
SATA controller
1x SATA controller integrated on the system board;
up to four SATA HDDs/SSDs can be connected to
the controller. The LSI Embedded MegaRAID
software (Software RAID) supports RAID levels 0, 1,
10.
1x single SATA3 connector for ODD
2x M.2 connector with support for SATA and PCIe
2 x 1Gbit/s LAN connector onboard (RJ45)
LAN controller
Remote Management Integrated Remote Management Controller
Controller
(iRMC S4/S5), 256 MB DDR3-800 SRAM for video,
IPMI 2.0 compatible
Trusted Platform
Module (TPM)
Infineon / separate module; TCG V2.0 compliant,
SPI support (option)
RX1330 M4
Operating Manual
97
Technical data
Slots - standard
Slot 1: PCIe Gen3 x8
(mechanical x8)
notched, up to 167,65 mm length, low profile
notched, up to 167,65 mm length, low profile
notched, up to 167,65 mm length, low profile
Slot 2: PCIe Gen3 x4
(mechanical x8)
Slot 3: PCIe Gen3 x8
(mechanical x8)
Slot notes
As an option, a full height riser module can be
installed. In this case the slot 2 is not available and
slot 3 can be equipped with a full height expansion
card.
Drive bays
HDD bay configuration up to 4x 3.5-inch HDD
up to 8x 2.5-inch HDD/SSD
up to 4x 2.5-inch PCIe SSD + 4x 2.5-inch HDD/SSD
up to 10x 2.5-inch HDD/SSD
1x 1.6-inch for Ultra Slim ODD
Accessible drive bay
98
OperatingManual
RX1330 M4
Technical data
Dimension/Weight
Rack (W x D x H)
482.6 mm (bezel) / 435,4 mm (body) x 610.1 mm x
42.85 mm
Height unit rack
1 HU
Installation depth in
rack
558,75 mm
Weight
8.3 - 13.5 kg
Weight notes
Rack mounting kit
Weight may vary depending on actual configuration
Rack mounting kit as option
Ventilation clearance
There must be a clearance of at least 200 mm in front of and behind the server
to ensure adequate ventilation of the subsystem.
Ambient conditions
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
10 °C ... 35 °C
5 °C ... 40 °C (with Cool-safe® ATD 40 °C)
5 °C ... 45°C (with Cool-safe® ATD 45 °C)
-25°C ... 60°C
Transport (2K2)
Humidity
10% ... 85% (non condensing)
Condensation during operation must be avoided!
RX1330 M4
Operating Manual
99
Technical data
Noise level (depending on the configuration)
The acoustic noise values are depending on the system configuration.
Standard configuration
SATA systems
SAS systems
(4x 2.5-inch HDD/SSD,
standard PSU)
(10x 2.5-inch SAS HDD,
redundant PSU)
Sound power level 4.2 B (standby)
LWAd (ISO 9296) 4.2 B (operation)
5.8 B (standby)
5.8 B (operation)
Sound pressure
level at adjacent
workstation LpAm
(ISO 9296)
26 dB (A) (standby)
26 dB (A) (operation)
40 dB (A) (standby)
40 dB (A) (operation)
Declared noise
emission
Standby
Operating (ISO 7779)
according to ISO ETSI 300 753 Class 3.1
9296
Electrical data: 300 W (standard PSU)
Rated voltage range
Rated frequency range
Max. rated current
100 - 240 V
50 Hz - 60 Hz
3.0 - 1.5 A (100 - 240 V)
Electrical data: 450 W (hot-plug PSU)
Rated voltage range
Rated frequency range
Max. rated current
100 - 240 V
50 Hz - 60 Hz
4.5 - 2.0 A (100 - 240 V)
100
OperatingManual
RX1330 M4
Technical data
Electrical data: Fujitsu battery unit (FJBU)
Max. output
380 W
Backup duration
Max. 2 seconds (380W), 4 minutes (280W)
with FJBU M2
Charge duration
Battery spec.
Battery life time
Input/Output voltage
Weight
4 hours to 90%, 5 hours to 100%
Nickel Metal-Hydride battery
5 years
12 V DC
1.2 kg
RX1330 M4
Operating Manual
101
Technical data
Compliance with standards
Product safety and ergonomics
International
IEC 60950-1 2nd Edition am 1 + am 2
IEC 62368-1:2014 (Second Edition)
Europe
Safety
EN 60950-1 2nd Edition
EN 62368-1:2014
EN 62479
Ergonomics
ISO 9241-3xx
EN 9241-3xx
EK1-ITB 2000:2018
USA / Canada
CSA-C22.2 No. 60950-1-07 2nd Edition am 1+
am 2
CAN/CSA-C22.2 No. 62368-1:2014
UL 60950-1 2ed. am1 + am2
UL 62368-1:2014
Australia / New Zealand AS/NZS 62368.1
AS/NZS 60950.1
Taiwan
CNS 14336-1
GB 4943.1
IS 13252-1
China
India
Electromagnetic compatibility
International
CISPR 32
CISPR 24
Europe
EN 55032 Class A
EN 55024
EN 61000-3-2
EN 61000-3-3
EN 300386 (on demand)
USA / Canada
FCC 47CFR part 15 Class A / ICES-003
Australia / New Zealand AS/NZS CISPR32 Class A
Taiwan
China
Japan
CNS 13438 Class A
GB 9245 / GB 17625
VCCI Class A / JEITA
102
OperatingManual
RX1330 M4
Technical data
Korea
KN 32 / KN 35
CE marking to EU directives
Europe
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility 2004/30/EU
RoHS Compliance
Europe
EN 50581
Taiwan
CNS 15663
V
CAUTION!
This device meets the requirements of Class A CISPR 22/32. This device
can cause radio interference in residential areas.
RX1330 M4
Operating Manual
103
Technical data
104
OperatingManual
RX1330 M4
9
Warranty and service
Warranty
The warranty regulations can be found online at:http://manuals.ts.fujitsu.com
under x86 Servers - Safety / Eco / Warranty
For Japan:
For the warranty regulations select " 製品保証ご案内 ( 無償修理期間 )"
Service
Telephone numbers of the local service partner can be found online at:
RX1330 M4
Operating Manual
105
Warranty and service
106
OperatingManual
RX1330 M4
|