EMERSON ROXAR User Manual

User Manual  
ROXA20034733  
March 2019  
Roxar Sacrificial Probe User Manual  
User Manual  
Contents  
ROXA20034733  
March 2019  
Contents  
3
Contents  
User Manual  
March 2019  
ROXA20034733  
4
User Manual  
Introduction  
ROXA20034733  
March 2019  
1
Introduction  
This manual provides general information and procedures for using the Roxar Sacrificial  
Probe, and is intended for use by qualified personnel. The information presented in this  
manual is not specific to a particular application, installation or process, and must be  
evaluated on a case-by-case basis by the operator. Contact Emerson for more information.  
1.1  
1.2  
Conformity to standards  
This document has been issued in compliance with the most common international  
standards for user manual documentation.  
Warnings  
WARNING  
The instructions and procedures described in this document may require special  
precautions to ensure the safety of the personnel performing the operations. Information  
that potentially raises safety issues is indicated by a warning symbol followed by a safety  
message.  
1.3  
1.4  
Acronyms and definitions  
Acronym  
Definition  
PPE  
Personal Protective Equipment  
Material Safety Data Sheet  
MSDS  
Personnel qualifications and safety  
You must read and follow all instructions, warnings and cautions to avoid personal injury  
or damage to property during system operation. Emerson is not responsible for damage or  
injury resulting from unsafe use of the product, lack of maintenance, incorrect installation  
of equipment, or system operation. Contact Emerson if you have questions about any  
applications and safety precautions described in this manual.  
Ensure that operators working on the equipment are following the end-user guidelines on  
the use of protective equipment including, but not limited to the following:  
Safety helmet/hard hat  
Steel-toed shoes  
Safety glasses  
Working gloves (suitable for mechanical operations)  
Chemical resistant latex gloves, or equivalent  
5
         
Introduction  
User Manual  
March 2019  
ROXA20034733  
Long sleeved fire-retardant shirt and fire-retardant trousers, or full-length fire-  
retardant coveralls  
Additional Personal Protective Equipment (PPE) may be required depending on facility  
requirements and Material Safety Data Sheet (MSDS) requirements. Failure to do so may  
result in personnel injury.  
1.5  
Warranty restrictions  
You must visually inspect all components for shipping damage and notify the carrier, if you  
find any shipping damage. Shipping damage is not covered by the warranty. The carrier is  
responsible for all repair and replacement costs resulting from shipment damage.  
1.6  
1.7  
Additional documentation and resources  
ROX000295904 - Roxar Mechanical Retrieval Tool User Manual  
ROX000337352 - Roxar Hydraulic Retrieval Tool User Manual  
Assistance  
The Roxar Global Service Centre is organized through a network of service centers  
worldwide, and supports all service requirements or technical queries.  
For the Product Support Help Desk, contact [email protected].  
6
     
User Manual  
Technical description  
ROXA20034733  
March 2019  
2
Technical description  
The term "probe" is collective noun for the equipment used to provide information relating  
to process changes and their effect on metal loss from corrosion and/or erosion. There are  
different types of probes with different measurement techniques.  
This manual describes the Roxar Sacrificial Probe. Contact Emerson for more information  
on other types of Roxar probes.  
2.1  
Roxar Sacrificial Probe  
The early detection of sand production in fields is one of the biggest challenges faced by  
oil and gas companies. High sand production can cause damage to pipes and instruments,  
pose a safety risk, and be very costly for operators. Therefore, the early warnings and  
detection of erosion is crucial for operators. The Roxar Sacrificial Sand Probe is used to  
provide information when sand erosion has exceeded the element thickness of the probe,  
in order to avoid erosion damage, or control sand production.  
The Roxar Sacrificial Probe is an intrusive sand probe that consists of a hollow tube and a  
holder. The Roxar Sacrificial Probe is inserted into a high velocity flow, and an indication is  
given by a pressure gauge, or a pressure transmitter, once the pressure has penetrated the  
sacrificial tube due to the wear caused by sand and other particles in the flow.  
The Roxar Sacrificial Probe can be installed in two ways:  
The Roxar Sacrificial Probe (Retrievable) is installed in an tee-type 2 in access fitting.  
The Roxar Sacrificial Probe (Non-retrievable ) is installed in taps welded directly onto  
the pipe or vessel (welding bosses or threadolets).  
Note  
If the Roxar Sacrificial Probe is installed in an tee-type 2 in access fitting system, the probe  
can be retrieved and replaced without any interruptions to the mainstream flow, or the  
need to depressurize the pipe.  
The sensing element of the Roxar Sacrificial Probe consists of a tube made from corrosion  
resistant material. The tube is closed at one end and threaded at the other end to mate  
with the probe nut. The nut enables the Roxar Sacrificial Probe to be attached to a solid  
plug and used in a Roxar Access Fitting Assembly with a tee.  
Emerson recommends placement of the probe within the pipeline, so that the midpoint of  
the sacrificial tube is placed approximately 60% into the pipeline diameter (ID). This  
placement allows for maximum theoretical sand impingement at center of line where the  
sand concentration and flow rates are often greatest. It also allows for heavier suspended  
participles flowing slightly lower in the flow stream to also contact the sacrificial tube.  
If there is sufficient flow velocity, the effect of sand and solids erodes through the  
Sacrificial Probe sensing element over time, and exposes the sealed system to the working  
pressure of the line. The pressure passes through a valve assembly and is registered by the  
pressure gauge.  
The Non-retrievable sacrificial system is available in a fixed configuration and can only be  
removed and replaced when the process line is not exposed to pressure. The Retrievable  
7
   
Technical description  
User Manual  
March 2019  
ROXA20034733  
sacrificial system can be removed and replaced under full operation, with the support of  
the Roxar Mechanical Retriever Tool or the Roxar Hydraulic Retriever Tool.  
Figure 2-1 shows the different ways in which the Roxar Sacrificial Probe can be installed.  
Figure 2-1: Roxar Sacrificial Probe Assembly  
A. Sacrificial Probe Assembly (Retrievable) mounted in a tee-type flareweld mechanical  
access fitting  
B. Sacrificial Probe Assembly (Retrievable) mounted in a tee-type flanged hydraulic access  
fitting  
C. Sacrificial Probe Assembly (Non-retrievable) mounted in a threadolet  
8
 
User Manual  
Technical description  
ROXA20034733  
March 2019  
2.2  
Main components  
The Roxar Sacrificial Probe (Retrievable) system in a 2 in tee-type hydraulic flanged access  
fitting consists of the following parts:  
Figure 2-2: Complete Hydraulic Retrievable Sacrificial Probe Assembly  
A. Plug  
B. Injection nut  
C. Cover  
D. Locking pins  
E. Pressure gauge  
F. Tee-type 2 in access fitting  
G. Flanged connection  
H. Sacrificial Probe  
9
 
Technical description  
User Manual  
March 2019  
ROXA20034733  
Figure 2-3: Complete Mechanical Retrievable Sacrificial Probe Assembly  
Figure 2-3 shows a Retrievable Sacrificial Probe system in a tee-type 2 in mechanical  
flareweld access fitting.  
A. Plug  
B. Injection nut  
C. Cover  
D. Shut-off valve  
E. Pressure gauge  
F. Tee-type 2 in access fitting, flareweld  
G. Sacrificial Probe  
10  
 
User Manual  
Technical description  
ROXA20034733  
March 2019  
Figure 2-4: Complete Roxar Sacrificial Probe (Non-retrievable) Assembly  
Figure 2-4 shows the parts of a Roxar Sacrificial Probe (Non-retrievable).  
A. Pressure gauge  
B. Shut-off valve  
C. Threadolet or welding boss  
D. Sacrificial Probe  
11  
 
Technical description  
User Manual  
March 2019  
ROXA20034733  
2.3  
Specifications and dimensions  
Specifications  
Value  
Probe body material  
Diameter of sacrificial tube  
Wall thickness of sacrificial tube  
Probe length  
Stainless Steel AISI 316L/316 (dual certification)  
Ø16 mm  
1 mm  
From 80 mm to 390 mm (depending on the  
type of probe)  
Probe installation in pipe  
Installed approximately 60% into the pipe  
diameter (ID)  
Maximum operating temperature  
Maximum operating pressure  
Mechanical interface  
204 °C  
6,000 psi  
½ in NPT (retrievable) and ¾ in NPT (non-  
retrievable)  
12  
 
User Manual  
Preparation  
ROXA20034733  
March 2019  
3
Preparation  
This section describes the prerequisites and preparations (including observations) to be  
carried out before installing the different parts of the equipment. The instructions cover  
the following equipment:  
Roxar Sacrificial Probe (Retrievable and Non-retrievable)  
Injection nut  
You can install the Roxar Sacrificial probe in two ways:  
Manually, by using hand tools before the system starts up, or during shut down when  
the line or vessel is empty and depressurized.  
By using a special retrieval tool during full operational conditions of the system. For  
more information, see Additional documentation and resources.  
Note  
The guidelines provided in this manual are based on the 2 in hydraulic or mechanical  
system that is being operated. If you are using a retrievable system, make sure you read  
and follow the instructions in the user manual of your system, including the  
recommendations for spare parts.  
3.1  
Tools  
Retrievable Probe with tee-type 2 in access fitting system  
In addition to the tools listed in the manuals for the applicable Retriever Tool (mechanical  
or hydraulic), you will need a 23 mm spanner to assemble the Sacrificial Probe into the  
injection nut.  
WARNING  
DANGER TO PERSONNEL AND EQUIPMENT. Make sure that the length of retriever tool  
available for the operation is compatible with the length of the Sacrificial Probe.  
Non-retrievable Probe  
You will need a 23 mm spanner to assemble the Roxar Sacrificial Probe into the pipe tap. A  
set of two adjustable spanners is also required to assemble the shut-off valve and the  
pressure gauge (or pressure transmitter, if applicable).  
WARNING  
DANGER TO PERSONNEL AND EQUIPMENT. Installation or replacement of a non-  
retrievable probe requires a depressurized, drained and ventilated pipe or vessel.  
13  
   
Preparation  
User Manual  
March 2019  
ROXA20034733  
3.2  
Consumables  
You do not need any additional consumables for non-retrievable sacrificial probes that are  
installed in a welding boss or threadolet.  
If the probe is installed in a retrievable type 2 in access fitting, you will need the spare parts  
that are listed under operational instructions for the applicable retriever tool (mechanical  
or hydraulic).  
In addition, a new probe and the following spares shall be available:  
Figure 3-1: Consumables for Roxar Sacrificial Probe Nut (Retrievable)  
A. Position 1  
B. Position 2  
C. Position 1  
3.2.1  
Part numbers for consumables  
Position  
Description  
Backup ring  
O-ring  
Material  
Part number  
Pos.1  
PTFE  
ROX000323092  
ROX000278467  
ROX000323093  
ROX000342560  
ROXA20035755  
ROX000339898  
ROXA20035756  
Pos.2  
VITON 75  
FKM938  
HNBR90  
ELAST-O-LION  
FR25/90  
FKM 75  
14  
 
User Manual  
Operating instructions  
ROXA20034733  
March 2019  
4
Operating instructions  
Introduction  
Generally, the Roxar Sacrificial Probe is operated only during the replacement of probe  
itself. Due the nature of the sensor, a local indication is provided by the pressure gauge (or  
a signal is sent to control room, if a pressure transmitter is applied) once the probe tube is  
eroded. That means if 1 mm of metal loss is eroded, the rate can be calculated by dividing  
the thickness of the tube (1 mm) by the time that elapsed since the probe was exposed to  
flow and until the indication came on the pressure gauge.  
It is important to highlight the importance of replacing the Sacrificial Probe as soon as  
there is metal loss due to erosion, which must be taken into consideration for assessment  
of pipe integrity and future production of the actual well.  
4.1  
Roxar Sacrificial Probe (Retrievable)  
Note  
To replace a Roxar Sacrificial Probe (Retrievable) installed in a 2 in access fitting, refer to  
the user manuals for the applicable retriever tool and 2 in access fittings.  
After you have retrieved the plug, injection nut and probe, replace the sealing device at  
the plug, the O-ring and the back-up ring at the injection nut and the Sacrificial Probe.  
The Sacrificial Probes are equipped with NPT threads. This means the threads have a  
tapered design, and in most cases that is enough to seal the connection. In order to  
prevent spiral leakage and avoid galling, Emerson recommends that you use some type of  
sealant (tape or paste) and apply the sealant to the male thread only.  
When using the tape sealant, wrap the threads in a clockwise motion starting at the first  
thread. As the layers are applied, work towards the imperfect (vanishing) thread. If the  
system that the connection being made to cannot tolerate foreign matter, leave the first  
thread exposed and apply the tape sealant as outlined above.  
When using paste sealant, apply to the threads with a brush, using the brush to work the  
sealant into the threads. Apply enough sealant to fill in all the threads all the way around.  
Follow the instructions on retrieval procedure to install the probe into the pipe.  
4.2  
Roxar Sacrificial Probe (Non-retrievable)  
To replace a Roxar Sacrificial Probe (Non-retrievable), you must first depressurize and drain  
the pipe. Once the pipe is confirmed to be depressurized and drained, unscrew the  
pressure gauge (or pressure transmitter), the shut-off valve and the eroded probe.  
The Sacrificial Probes are equipped with NPT threads. This means the threads have a  
tapered design, and in most cases that is enough to seal the connection. In order to  
prevent spiral leakage and avoid galling, Emerson recommends that you use some type of  
sealant (tape or paste) and apply the sealant to the male thread only.  
When using the tape sealant, wrap the threads in a clockwise motion starting at the first  
thread. As the layers are applied, work towards the imperfect (vanishing) thread. If the  
15  
     
Operating instructions  
User Manual  
March 2019  
ROXA20034733  
system that the connection being made to cannot tolerate foreign matter, leave the first  
thread exposed and apply the tape sealant as outlined above.  
When using paste sealant, apply to the threads with a brush, using the brush to work the  
sealant into the threads. Apply enough sealant to fill in all the threads all the way around.  
Install the new probe into the existing pipe tap, followed by the shut-off valve and pressure  
gauge (or pressure transmitter).  
16  
User Manual  
Maintenance  
ROXA20034733  
March 2019  
5
Maintenance  
The Roxar Sacrificial Probe does not require any maintenance during normal operational  
conditions.  
Emerson recommends limited routine inspections to ensure that there are no visual  
damages on pressure gauges, covers, shut-off valves and access points.  
WARNING  
DANGER TO PERSONNEL AND EQUIPMENT. Do not remove the pressure gauge or the  
pressure transmitter with the shut-off valve on its open position, even if the probe is still  
sealed, and the pressure indication is zero.  
17  
 
*ROXA20034733*  
ROXA20034733  
2019  
Roxar  
Head Office Roxar products:  
+47 51 81 8800  
CIS: +7 495 504 3405  
Europe: +47 51 81 8800  
North America: +1 281 879 2300  
Middle East: +971 4811 8100  
Asia Pacific: +60 3 5624 2888  
Australia: 1 300 55 3051  
Latin America:  
Portuguese: +55 15 3413 8888  
Spanish: + 52 55 5809 5000  
©
2019 Roxar AS. All rights reserved.  
The Emerson logo is a trademark and service mark of Emerson Electric Co. Roxar is a trademark of  
Roxar ASA. All other marks are property of their respective owners.  
Roxar supplies this publication for informational purposes only. While every effort has been made to  
ensure accuracy, this publication is not intended to make performance claims or process  
recommendations. Roxar does not warrant, guarantee, or assume any legal liability for the accuracy,  
completeness, timeliness, reliability, or usefulness of any information, product, or process described  
herein. All sales are governed by our terms and conditions, which are available on request. We  
reserve the right to modify or improve the designs or specifications of our products at any time  
without notice. For actual product information and recommendations, please contact your local  
Roxar representative.  
Roxar products are protected by patents. See http://www.emerson.com/en-us/automation/brands/  

York Air Conditioner 035 09319 User Manual
Xerox Workcentre 7675 User Manual
Whirlpool 1172397 User Manual
Sanyo Uf652436f User Manual
Sanyo Ch1852 User Manual
Sanyo 36u72r User Manual
Quasar Hq 2121rh User Manual
Mitsubishi Electronics Lossnay Lgh 200rx4 E User Manual
MAKITA MAC500 User Manual
LG LPTP1231W User Manual