Craftsman Propane Heater User Manual

PROPANE  
CONSTRUCTION HEATER  
USER’S MANUAL AND OPERATING INSTRUCTIONS  
Dyna-Glo™DELUX RMC-FA40DGD  
(40,000 BTU/HR,  
FORCED - AIR)  
RMC-FA50DGD  
RMC-FA60DGD  
RMC-FA100DGD  
(30,000/50,000 BTU/HR, FORCED - AIR)  
(30,000/60,000 BTU/HR, FORCED - AIR)  
(70,000/100,000 BTU/HR, FORCED - AIR)  
MODELS:  
RMC-FA125DGD/LPFA125DGD (70,000/125,000 BTU/HR, FORCED - AIR)  
RMC-FA150DGD  
(120,000/150,000 BTU/HR, FORCED - AIR)  
RMC-FA40/DGP/DGP-01  
RMC-FA50/DGP/DGP-01  
RMC-FA60/DGP/DGP-01  
RMC-FA100/DGP/DGP-01  
RMC-FA125/DGP/DGP-01  
LPFA125H/LPFA125H-01  
RMC-FA150/DGP/DGP-01  
(40,000 BTU/HR, FORCED - AIR)  
Dyna-Glo™Pro  
MODELS:  
(30,000/50,000 BTU/HR, FORCED - AIR)  
(30,000/60,000 BTU/HR, FORCED - AIR)  
(70,000/100,000 BTU/HR, FORCED - AIR)  
(70,000/125,000 BTU/HR, FORCED - AIR)  
(120,000/150,000 BTU/HR, FORCED - AIR)  
FA40DGP-01  
C
US  
ANS Z83.7-2011 CSA 2.14-2011  
adequate ventilation must be provided.  
GHP Group, Inc.  
6440 w howard St  
niles, il 60714-3302  
FA60DGP/DGP-01  
LPFA125H/H-01  
GENERAL HAZARD WARNING  
Failure To CoMply wiTh The preCauTionS and inSTruCTionS provided wiTh  
ThiS heaTer, Can reSulT in deaTh, SeriouS Bodily injury and properTy loSS,  
or daMage FroM The hazardS oF Fire, exploSion, Burn. aSphyxiaTion, CarBon  
Monoxide poiSoning, and/or eleCTriCal ShoCk.  
only perSonS who Can underSTand and Follow The inSTruCTionS Should  
uSe or ServiCe ThiS heaTer.  
iF you need aSSiSTanCe or heaTer inForMaTion SuCh aS an inSTruCTion  
Manual, laBelS, eTCeTera, ConTaCT The ManuFaCTurer.  
CONSUMER: retain this manual for future reference.  
Questions, problems, missing parts? Before returning to your retailer, call our customer  
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday  
or email us at [email protected]  
Printed in China  
50-10-104  
Rev. 2013-06-05  
PROPANE CONSTRUCTION HEATER  
TABLE OF CONTENTS  
Introduction & Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
• General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
• Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
• Unpacking Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6  
• Size & Capacity Of Propane Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
• Installation To The Propane Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
• Refilling The Propane Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
• Leak Checking & Positioning Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
• Lighting & Shutdown Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10  
Test Firing Heater & Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
• Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
• Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 - 13  
Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15, 17, 19  
propane ConSTruCTion heaTer illuSTraTed / parTS Breakdown:  
RMC-FA40, 50 & 60 SeRIeS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
RMC-FA100DGD, RMC-FA125DGD, LPFA125H & RMC-FA150DGD . . . . . . . . . . . . . . . . . . . . . . 16  
RMC-FA100DGP/DGP-01, RMC-FA125DGP/DGP-01 & LPFA125DGD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
• Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
: Fire, Burn, inhalaTion, and exploSion hazard, keep Solid  
CoMBuSTiBleS, SuCh aS Building MaTerialS, paper or CardBoard, a SaFe  
WARNING  
diSTanCe away FroM The heaTer aS reCoMMended By The inSTruCTionS.  
never uSe The heaTer in SpaCeS whiCh do or May ConTain volaTile or  
airBorne CoMBuSTiBleS, or produCTS SuCh aS gaSoline, SolvenTS, painT  
ThinnerS, duST parTiCleS or unknown CheMiCalS.  
CALIFORNIA PROPOSITION 65: Fuels used in gas or oil fired appliances and the products of  
combustion of such fuels, contain chemicals known to the State of California to cause cancer,  
birth defects or other reproductive harm. This product contains chemicals, including lead and lead  
compounds, known to the State of California to cause cancer, birth defects or other reproductive  
harm. Wash hands after handling.  
: using this heater in a residential garage requires that the heater is positioned  
WARNING  
so that it is protected against any possible damage by a moving vehicle, etc. it must be  
positioned so that the base of the heater is no less than 18 in (450 mm) above the garage floor or  
8 ft (2450 mm) in repair garages. The heater must be placed on a stable surface. Do not place it on  
a chair, ladder, etc. raising the heater will reduce BuT noT eliminate the possibility of lighting the  
vapor of any flammable liquids which may be improperly stored or accidentally spilled. If the smell of  
gasoline is present, do noT operate this heater until the area has been properly ventilated.  
WARNING: CONSTRUCTION HEATERS ARE NOT FOR USE IN  
GARAGES IN CANADA.  
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
2
PROPANE CONSTRUCTION HEATER  
Dyna-Glo ProPane ForceD air construction Heaters  
The heater is designed and approved for use as a construction heater under anS z83.7 CSa 2.14. it is hard  
to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY  
AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.  
Other standards govern the use of fuel gases and heat producing products in specific applications.  
your local authority can advise you about these.  
IMPORTANT: read ThiS uSer’S Manual CareFully and CoMpleTely BeFore Trying  
To operaTe or ServiCe ThiS heaTer. iMproper uSe oF ThiS heaTer Can CauSe  
SeriouS injury or deaTh FroM Fire, exploSion and CarBon Monoxide poiSoning.  
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended  
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. all the  
products of combustion generated by the heater are forced through the heater and released into the area being  
heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount  
of carbon monoxide. humans can tolerate small amounts of carbon monoxide for short periods. Carbon  
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning  
or death.  
: noT For uSe wiTh duCT work.  
WARNING  
sPeciFications  
ModelꢀNo.  
RMC‐FA40DGP/  
DGP‐01  
FA50ꢀSeries  
FA60ꢀSeries  
RMC‐FA100DGD/  
DGP/DGP‐01  
LPFA125DGD/  
RMC‐FA125DGP/  
DGP‐01  
LPFA125H/  
RMC‐FA125DGD  
RMC‐FA150DGD  
30,000ꢀBTU/hr  
50,000ꢀBTU/hr  
30,000ꢀBTU/hr  
60,000ꢀBTU/hr  
70,000ꢀBTU/hr  
100,000ꢀBTU/hr  
70,000ꢀBTU/hr  
125,000ꢀBTU/hr  
70,000ꢀBTU/hr  
125,000ꢀBTU/hr  
120,000ꢀBTU/hr  
150,000ꢀBTU/hr  
InputꢀRating  
TypeꢀofꢀGas  
40,000ꢀBTU/hr  
Propane  
Propane  
Propane  
Propane  
Propane  
Propane  
Propane  
GasꢀSupplyꢀPressureꢀtoꢀ  
RegulatorꢀMaximum  
CylinderꢀPressure  
5psig  
CylinderꢀPressure  
CylinderꢀPressure  
CylinderꢀPressure  
CylinderꢀPressure  
CylinderꢀPressure  
CylinderꢀPressure  
Minimumꢀ(forꢀpurposeꢀofꢀ  
InputꢀAdjustment)  
5psig  
5psig  
5psig  
5psig  
5psig  
5psig  
ManifoldꢀPressure  
GasꢀConsumption  
ElectricalꢀInput  
11"ꢀW.C  
11"ꢀW.C  
11"ꢀW.C  
11"ꢀW.C  
11"ꢀW.C  
11"ꢀW.C  
11"ꢀW.C  
1.4lbs/hr  
2.3lbs/hr  
1.4lbs/hr  
2.8lbs/hr  
3.3lbs/hr  
4.6lbs/hr  
3.3lbs/hr  
5.8lbs/hr  
3.3lbs/hr  
5.8lbs/hr  
5.6lbs/hr  
7.0lbs/hr  
1.9lbs/hr  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.68amps  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.65amps  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.65amps  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.7amps  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.7amps  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.7amps  
120V,ꢀ60Hz,ꢀ1Øꢀ  
0.7amps  
Amperage ꢀꢀLoad  
ꢀꢀUnload  
ꢀꢀLoad  
3550rpm  
3000rpm  
3570rpm  
3300rpm  
3570rpm  
3300rpm  
3580rpm  
3300rpm  
3580rpm  
3300rpm  
3580rpm  
3300rpm  
3580rpm  
3300rpm  
Fan  
Ignition  
Piezo/ManualꢀSpark  
0.16"ꢀ(4mm)  
ContinuousꢀSpark  
0.16"ꢀ(4mm)  
ContinuousꢀSpark  
0.16"ꢀ(4mm)  
ContinuousꢀSpark  
0.16"ꢀ(4mm)  
ContinuousꢀSpark  
0.16"ꢀ(4mm)  
ContinuousꢀSpark  
0.16"ꢀ(4mm)  
ContinuousꢀSpark  
0.11"ꢀ(2.8mm)  
SparkꢀGap  
25.6"x12.7"x15.6"  
(650x323x396)mm  
25.6"x11.8"x16.1"  
(650x300x409)mm  
26.6"x13.0"x17.3"  
(676x330x439)mm  
25.6"x11.8"x16.1"  
(650x300x409)mm  
26.2"x11.5"x17.2"  
(666x292x436)mm  
25.6"x12.7"x15.6"  
(650x323x396)mm  
19.3"x8.3"x15.2"  
(490x211x386)mm  
19.3"x8.3"x15.2"  
(490x211x386)mm  
19.3"x8.3"x15.2"  
(490x211x386)mm  
25.6"x11.8"x16.1"  
(650x300x409)mm  
Sizeꢀ(LxWxH)  
Weight  
13.7lbs/14lbs  
(6.2kg/6.35kg)  
21.5lbs/21lbs/20.8lbs  
(9.75kg/9.5kg/9.4kg)  
21.9lbs/21lbs/20.8lbs  
(9.9kg/9.5kg/9.4kg)  
20.3lbs/21.5lbs  
(21.9kg/9.75kg)  
14.3lbsꢀ(6.48kg)  
14.3lbsꢀ(6.48kg)  
21.2lbsꢀ(9.6kg)  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
3
PROPANE CONSTRUCTION HEATER  
General saFety instruction  
accidents are always tragic especially because so many of them could have been prevented with little care  
and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.  
iMPortant saFety instruction  
• Children should be carefully supervised, when they are in the area.  
• Always maintain proper clearance from combustible materials. Minimum clearance from combustibles:  
Side - 24” (61cm); Top - 36” (91cm); Front - 72” (1.8M). Floor - combustible. Not for use on finished floors.  
• Heater must be placed on level and stable surface.  
• Never place anything including clothes or other flammable items on the heater.  
• The appliance area shall be kept clear and free from combustible materials, gasoline and other flammable  
vapours and liquids.  
• Do not modify or operate a heater which has been modified.  
• Adequate clearance for accessibility and for combustion & ventilation air supply must be maintained at all  
times when the heater is operating.  
• Service and repair should be done by a qualified service person. The heater should be inspected  
before each use and at least annually by a qualified person. More frequent cleaning may be required as  
necessary. do not service while hot or operating.  
• Never connect heater to an unregulated gas supply.  
• The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only,  
do not convert heater to any other gas. installation must conform to local codes or, in the absence of local  
codes, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the  
Natural Gas and Propane Installation Code CSA B149.1  
• The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure,  
respectively. use only the regulator & hose assembly provided with the heater. inspect the regulator/hose  
assembly prior to each use of the heater. if there is excessive abrasion or wear, or hose is cut, replace with  
regulator/hose assembly listed on the parts list prior to using this heater.  
• Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame  
to check for gas leaks.  
• The electrical connection & grounding must comply with National electrical Code. ANSI/NFPA 70 or in  
Canada CSa C22.1, Canadian electrical Code, part 1. use only a properly grounded three  
(3) prong receptacle.  
• Do not restrict inlet or outlet by any means. The flow of combustion and ventilation air is not to be obstructed.  
• This heater should not be directed toward any propane-gas container within 20 ft (6M). The heater must be  
located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container.  
• The propane cylinder supply system must be arranged to provide for vapour withdrawal from the  
operating cylinder.  
• This heater is not to be used with external thermostats, timers or other devices that control or alter electrical  
supply to the heater.  
: Motor and fan must be running before lighting, during operation and at shutdown,  
in order to prevent a flame-out condition which could result in personal injury or property damage.  
WARNING  
ProDuct Features  
• Portable & Stable  
• 100% Safety Shutoff System  
• Continuous Adjustable Input Ratings  
(except FA40)  
• Wind Resistant & Rain Protected  
• Continuous Spark Ignition or  
Piezo electric Spark Ignition  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
4
PROPANE CONSTRUCTION HEATER  
unPacKinG Heater  
1. remove heater from carton.  
2. Remove all protective packing applied to heater for shipment.  
3. Retain cartons and packaging material until unit is operated and found in good condition.  
4. Check heater for any shipping damage. If heater shows any external or internal  
damage, promptly inform dealer/distributor where you purchased heater.  
Assembly Components and Instructions for Steel Base Units:  
Contents:  
Tools required for assembly:  
All Models: adjustable wrench  
FA100 - FA150: phillips head  
Screw driver  
Assembly Time:  
5 Minutes  
All Models: unit, Manual, hose and regulator  
assembly  
FA100 - FA150 Series Includes:  
2 Cord Wrap Attachments, 4 Screws (ST3.5x10)  
1. Assembling the Cord Wrap Attachments:  
(FA100 - FA150 Series Only)  
Parts Required:  
4 Screws (ST3.5x10),  
and 2 Cord wrap attachments  
place the cord wrap attachment  
as shown, then use phillips  
screwdriver to tighten the  
screws and secure the  
cord wrap attachments.  
2. Regulator and Hose Connection:  
(All Models)  
See figure on right.  
Connect the hose tightly to  
the heater using a wrench.  
please also refer to  
page 8 in the manual.  
hose assembly  
Tighten, clockwise,  
use a wrench  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
5
PROPANE CONSTRUCTION HEATER  
Assembly Components and Instructions for Plastic Base Units:  
Contents:  
Tools required for assembly:  
All Models: adjustable wrench  
FA125 Series: phillips head  
Screw driver  
Assembly Time:  
5 Minutes  
All Models: unit, Manual, hose and regulator  
assembly, adjustable leg, 2 height Control Screws  
FA125 Series Includes:  
2 Cord Wrap Attachments, 4 Screws (ST3.5x10)  
1. Assemble the Leg:  
Parts Required: adjustable leg  
place the heater as shown,  
insert the leg into holes of  
the base, then adjust  
to the desired height.  
2. Assemble the Height Control Screw:  
Parts Required: height Control Screw 2 pcs  
Turn the height Control Screw  
clockwise to lock it. Turn the  
height Control Screw counter-  
clockwise to unlock it.  
Lock, clockwise  
3. Assembling the Cord Wrap Attachments:  
Parts Required: 4 Screws (ST3.5X10)  
and 2 Cord wrap attachments  
place the cord wrap attachments  
as shown, then use phillips  
screwdriver to tighten the screws  
and secure the cord wrap attachments.  
4. Regulator and Hose Connection:  
hose assembly  
See figure on right.  
Connect the hose tightly to  
the heater using a wrench.  
please also refer to  
Tighten, clockwise,  
page 8 in the manual.  
use a wrench  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
6
PROPANE CONSTRUCTION HEATER  
inForMation on siZe * caPacity oF ProPane Gas cylinDers:  
The chart below shows the number and size of propane tanks needed to run this heater.  
*Less gas is vaporized at lower temperatures.  
You may need two or more 100 pound tanks or one larger tank in colder weather.  
(See the parts list for your model of heater to get the specified regulator assembly.)  
Number of Tanks  
Temperature  
100,000 -  
(°F) At tank  
40,000-60,000 BTu/h  
150,000 BTU/h  
125,000 BTU/h  
above 32°F  
1 - 20lb  
1 - 20lb  
2 - 100lb  
2 - 100lb  
2 - 100lb  
32°F  
2 - 100lb  
20°F  
10°F  
-10°F  
-20°F  
1 - 20lb  
1 - 20lb  
2 - 20lb  
1 - 100lb  
2 - 100lb  
3 - 100lb  
3 - 100lb  
3 - 100lb  
Use Larger Tank  
Use Larger Tank  
Use Larger Tank  
Use Larger Tank  
The propane (LP) gas tank must also be equipped with the following:  
• A collar to protect the Propane gas valve.  
• A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the  
american national Standards for Compressed gas Cylinder valve outlets and inlet  
Connections.  
• A safety relief valve having direct communications with the vapor space of the tank.  
• An arrangement of vapor withdrawal.  
The propane (LP) gas pressure regulator and hose assembly supplied with  
this heater must be used without alteration.  
The hose assembly shall be visually inspected prior to each use of the heater. if it is evident  
that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the  
heater being put into operation. The replacement hose assembly shall be that specified  
by the manufacturer.  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
7
PROPANE CONSTRUCTION HEATER  
installation to tHe ProPane Gas tanK  
IMPORTANT: you must use a propane/lp gas supply cylinder that is compatible with the connection device  
provided with the hose and regulator.  
regulator  
propane/lp  
Supply valve  
propane/lp  
Tank  
Fuel gas  
Fitting  
hose to  
heater  
hose to regulator  
hose Fitting  
Connector inlet  
FIGURE 2  
FIGURE 3  
FIGURE 1  
1. Provide propane/LP supply system. ensure that the valve on the cylinder is fully closed by turning the knob  
fully clockwise ( ). ensure that the cylinder is fully upright for vapor withdrawl. (see size/capacity, page 7).  
2. Connect hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.  
3. Connect fuel gas fitting hose/regulator assembly to propane LP tank(s).  
3a. For units with a POL fitting (see figure 1) turn fuel fitting counterclockwise into threads on tank. Tighten  
firmly using a wrench. Some models have a hand wheel that can be used to tighten the fitting. This hand  
wheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT:  
Position regulator so that hose leaving the regulator is in a horizontal position.  
3b. For units with a QCC fitting (see figure 2) turn QCC gas fitting clockwise onto threads on tank. Tighten  
firmly using your hand (DO NOT USe A WReNCH). IMPORTANT: Position regulator so that the regulator  
vent is pointing down toward the floor and the arrow on the regulator is visible.  
4. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTe: If not opened slowly, excess flow  
device in regulator may stop gas flow. If this happens, close propane/LP supply valve, wait one minute  
(or until you hear a click) and open again slowly.  
5. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints.  
Bubbles forming show a leak that must be corrected.  
6. Close propane / lp supply valve before attempting to repair connection.  
: Purging and filling of LP gas tanks must be performed by personnel who  
has been thoroughly trained in accepted lp gas industry procedures. Failure to follow  
WARNING  
these instructions may result in explosion, fire, severe personal injury, or death.  
reFillinG tHe ProPane Gas tanK  
ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.  
• Turn heater gas valve knob and gas tank valve to OFF position.  
• Propane tank valve equipped with the old style fitting has LeFT HANDeD THReADS. Turn POL fitting  
CLOCKWISe to loosen. Protect POL fitting when disconnected from tank.  
• Have tank filled by your local Propane gas supplier.  
• Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTeRCLOCKWISe.  
• With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks  
with soap solution.  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
8
PROPANE CONSTRUCTION HEATER  
ProPane saFety  
Propane is safe to use when properly handled. Careless handling of the Propane gas tank could  
result in fire and/or an explosion. Therefore:  
• Always keep tank/cylinder securely fastened in an upright position.  
• Avoid tipping tank on its side when connected to a regulator since this may cause damage to  
diaphragm in regulator.  
• Handle valves with care.  
• Never connect an unregulated Propane tank to construction heater.  
• Do not subject Propane tank to excessive heat.  
• Tightly close the gas shutoff valve on the Propane tank after each use.  
• The POL fitting must be protected when disconnected from the propane tank.  
• Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance.  
THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING, GARAGE  
OR ANY OTHER ENCLOSED AREA.  
leaK cHecKinG  
Check all gas connections with a soap solution to be sure they are tight and leak proof.  
• The installation of your heater must meet all local codes and/or gas utility requirements or, in the  
absence of local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA  
58 and the Natural and Propane Installation Code, CSA B149.1.  
• The minimum clearances to combustible construction: Side - 24” (61cm); Top - 36” (91cm);  
Front - 72” (1.8M); Floor - combustible, must be maintained at all times.  
• The hose assembly should be visually inspected prior to each use of the heater. If it is evident that  
there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being  
put into operation.  
• The replacement hose assembly shall be that specified by the manufacturer (Refer to parts list).  
liGHtinG instructions  
: Motor and fan must be running before lighting, during operation and shutdown, in  
WARNING  
order to prevent a flame-out condition which could result in personal injury or property damage.  
NOTE: This heater uses a continuous spark ignition system. This unit will continue to make a clicking/  
ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob  
positioning.  
1. Connect power cord to a properly grounded three (3) prong 120V, 60Hz, single phase receptacle.  
2. Turn gas valve knob clockwise  
3. Wait five (5) minutes to clear any gas. Then smell for gas, if you don’t smell gas, go to next step.  
4. Turn gas supply ON by turning Propane tank valve counterclockwise  
5. Push in and turn gas control knob counterclockwise to “LOW/IGN”. This will light the burner. If  
to OFF position.  
.
needed, keep pressing control knob until the burner lights and keep depressing and turning from  
OFF to LOW/IGN on Piezo electric spark models. (“HIGH/IGN”: In case of FA40 series)  
6. Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds  
release valve knob.  
7. if burner does not stay lit, repeat the lighting procedure.  
8. When burner is lit, turn gas valve knob counterclockwise  
FA40 series).  
to desired setting. (All models, except  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
9
PROPANE CONSTRUCTION HEATER  
sHutDoWn instructions  
: Motor and fan must be running before lighting, during operation and at shutdown,  
in order to prevent a flame-out condition which could result in personal injury or property damage.  
WARNING  
Turn gas valve knob clockwise  
to OFF position.  
Turn gas supply OFF by turning Propane tank valve clockwise  
to close.  
disconnect the power cord once the heater has cooled to ambient temperature.  
test FirinG Heater  
Test fire your construction heater, following the lighting instructions applicable to the gas control sys-  
tem employed. Leak test all gas connections with soap solution. Soap bubbles indicate gas leakage.  
DO NOT use a match or flame to test for gas leaks.  
storaGe  
Never store a Propane gas tank inside a building or in the vicinity of any gas or oil burning appliance.  
When the Propane tank is not disconnected from the construction heater, the gas tank and heater  
must be stored outdoors in a well ventilated area, out of the reach of children. if for any reason the  
heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well ventilated  
area out of reach of children, in accordance with the standard for the the Storage and handling of  
Liquefied Petroleum Gases, ANSI / NFPA 58 and CSA B149.1, Natural Gas and Propane Installation  
Code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is  
disconnected from the heater.  
Maintenance instructions  
1. Turn unit off, allow heater to fully cool and disconnect propane hose before performing any Mainte-  
nance  
functions. unplug the unit from the 120v receptacle.  
2. Keep unit clean and keep the inside of the torpedo housing debris free.  
3. Have unit checked by a qualified technician at least once a year, preferably prior to the heating  
season.  
rePlaceMent Parts  
Warning: Use only original replacement  
parts. This Heater must use design-specific  
parts. Do not substitute or use generic parts.  
Improper replacement parts could cause  
serious or fatal injuries.  
when calling ghp group inc., have ready:  
your name  
your address  
how heater was malfunctioning  
serial number of heater  
model number of heater  
replacement part number  
This will also protect your warranty coverage  
for parts replaced under warranty.  
parts warranty and non-warranty: Contact au-  
thorized dealers of this product. If they can not  
supply original replacement part(s), either con-  
tact your nearest parts Central or ghp group  
inc., Technical Service department at 1-877-  
447-4768.  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
10  
PROPANE CONSTRUCTION HEATER  
troublesHootinG  
PROBLEM  
POSSIBLEꢀCAUSE  
CORRECTIVEꢀACTION  
1. Controlꢀdialꢀisꢀoffꢀandꢀunitꢀis  
clicking/4cking  
1. Thisꢀheaterꢀusesꢀaꢀcon4nuousꢀspark  
igni4onꢀsystem.ꢀThisꢀunitꢀwillꢀcon4nue  
toꢀmakeꢀaꢀclicking/4ckingꢀsoundꢀatꢀall  
4mesꢀbeforeꢀigni4on,ꢀaAerꢀigni4on  
andꢀduringꢀopera4on,ꢀregardlessꢀof  
valveꢀknobꢀposi4oning.  
1. Noꢀcorrec4veꢀac4onꢀisꢀneeded.  
2. Theꢀunitꢀisꢀ4cking/clickingꢀ  
whileꢀtheꢀheaterꢀisꢀlit.  
1. Thisꢀheaterꢀusesꢀaꢀcon4nuousꢀspark  
igni4onꢀsystem.ꢀThisꢀunitꢀwillꢀcon4nue  
toꢀmakeꢀaꢀclicking/4ckingꢀsoundꢀatꢀall  
4mesꢀbeforeꢀigni4on,ꢀaAerꢀigni4on  
andꢀduringꢀopera4on,ꢀregardlessꢀof  
valveꢀknobꢀposi4oning.  
1. Noꢀcorrec4veꢀac4onꢀisꢀneeded.  
3. Fanꢀdoesꢀnotꢀturnꢀwhen  
electricalꢀconnec4onꢀisꢀmade.  
1. Noꢀelectricꢀpowerꢀtoꢀheater.  
1. Checkꢀcurrentꢀtoꢀelectricꢀoutlet.ꢀIfꢀvoltageꢀisꢀcorrect,  
checkꢀpowerꢀcordꢀandꢀextensionꢀcordꢀfor  
2. Fanꢀbladeꢀcontactsꢀinsideꢀofꢀheaterꢀhousing. 2. Beꢀsureꢀthatꢀhousingꢀisꢀnotꢀdamaged.ꢀMakeꢀsure  
thereꢀareꢀnoꢀobstruc4onsꢀtoꢀtheꢀfan.  
3. Fanꢀblade(s)ꢀbent  
4. Fanꢀmotorꢀdefec4ve.  
3. Straightenꢀblade(s)ꢀtoꢀmatchꢀothers.  
4. Replaceꢀmotor.  
4. Heaterꢀwillꢀnotꢀfire.  
1. Noꢀsparkꢀatꢀignitor.  
1. Checkꢀignitorꢀwire.ꢀReꢁaQachꢀorꢀ4ghtenꢀifꢀloose.  
CheckꢀSparkꢀmodule.ꢀReplaceꢀifꢀnecessary.  
2. Setꢀgapꢀ(Seeꢀspecifica4onsꢀforꢀgap).ꢀ  
3. ReplaceꢀSparkꢀPlug.  
2. Improperꢀsparkꢀgap.  
3. Badꢀelectrode.  
5. Heaterꢀquitsꢀwhile  
running.  
1. Internalꢀtemperatureꢀtooꢀhighꢀcausingꢀlimitꢀ  
switchꢀtoꢀshutꢀdownꢀopera4on.  
1. Ifꢀtheꢀheatersꢀoutputꢀisꢀrestricted,ꢀinternalꢀtemperature  
becomesꢀtooꢀhigh.ꢀMoveꢀheaterꢀawayꢀfrom  
anyꢀobstruc4ons.  
2. DamagedꢀControlꢀValve.  
2. ReplaceꢀControlꢀValve.  
3. Dustꢀorꢀdebrisꢀbuildꢁupꢀinsideꢀofꢀheater.  
3. Cleanꢀinsideꢀofꢀheater.  
Always be sure to follow proper maintenance procedures, by cleaning the heater once per  
month during regular usage, and check spark gap at least once per season.  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
11  
PROPANE CONSTRUCTION HEATER  
WirinG DiaGraMs  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
12  
PROPANE CONSTRUCTION HEATER  
WirinG DiaGraMs  
*100K,125K & 150K Models only  
*100K,125K & 150KSólo modelos  
*100K,125K & 150K Les modèles Seulement  
*
* *  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
13  
PROPANE CONSTRUCTION HEATER  
rePlaceMent Parts list  
MODELS: FA40 Series  
FA50 Series  
FA60 Series  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
14  
PROPANE CONSTRUCTION HEATER  
rePlaceMent Parts list  
PARTꢀNUMBER  
ITEMꢀNo.ꢀ  
DESCRIPTION  
QTY  
40ꢀSERIES  
50ꢀSERIES  
60ꢀSERIES  
1
2
3
4
5
6
7
8
9
INNERꢀSHELLꢀꢀASSEMBLY  
NOZZLE  
FLAMEꢀCAP  
THERMALꢀSWITCHꢀBRACKET  
THERMALꢀSWITCHꢀ  
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2304818  
*2304829  
2304819  
2304826  
2201373  
2304578  
2201375  
2304885  
2304830  
2305403  
2315915  
2315956  
2315312  
N/A  
2101447  
2305426  
2001355  
2001077  
2000384  
2304823  
2001332  
2304949  
2305909  
2304821  
2304828  
2305411  
2304937  
5050200  
N/A  
2304624  
2304923  
2305405  
2201368  
2304831  
2201372  
2304925  
2305407  
2101451  
2305466  
2304927  
2305409  
2304510  
2305467  
2201371  
N/A  
2201369  
*5002199  
*5002540  
TYQ‐9C‐3000  
*5055297  
*5055414  
TYQ‐9C‐4572  
2304818  
*2304942  
2304819  
2304826  
2201563  
2304578  
2201375  
2304885  
2304830  
2305403  
2315915  
2315956  
2315312  
N/A  
2101447  
2305426  
2001355  
2001077  
2000384  
2304823  
2001332  
2304949  
2305447  
2304821  
2304828  
2305411  
2304937  
5050510  
N/A  
2304624  
2304923  
2305405  
2101670  
2304831  
2201372  
2304925  
2305407  
2101451  
2305466  
2304927  
2305409  
2304510  
2305467  
2201371  
2201391  
2201369  
*5002614  
*5055533  
TYQ‐10C‐3000  
*5055298  
*5055415  
TYQ‐10C‐4572  
2304818  
*2325121  
2325120  
2304826  
2201599  
2304578  
2206033  
2304885  
2304830  
2305403  
2315915  
2315956  
2315312  
N/A  
2101447  
2305426  
2001355  
2001077  
2000384  
2304823  
2001332  
2304949  
2304547  
2304821  
2304828  
2305411  
2304937  
5051033  
N/A  
2304624  
2304923  
2305405  
2101670  
2304831  
2201372  
2304925  
2305407  
2101451  
2305466  
2304927  
2305409  
2304510  
2305467  
2201371  
2201391  
2201369  
*5002614  
*5055533  
TYQ‐10C‐3000  
*5055298  
*5055415  
TYQ‐10C‐4572  
NOZZLEꢀNUT  
SPARKꢀPLUGꢀASSEMBLY  
THERMOCOUPLEꢀASSEMBLYꢀ(1130/1474‐425L)  
GASꢀTUBINGꢀASSEMBLY  
OUTERꢀSHELLꢀ‐ꢀORANGE  
OUTERꢀSHELLꢀ‐ꢀBLACK  
10  
OUTERꢀSHELLꢀ‐ꢀGRAY  
OUTERꢀSHELLꢀ‐ꢀBLUE  
11  
12  
CORDꢀWRAPꢀ(selectꢀmodelsꢀonly)  
HANDLEꢀASSEMBLYꢀ‐ꢀBLACK  
HANDLEꢀASSEMBLYꢀ‐ꢀGRAY  
SCREWꢀ‐ꢀHANDLEꢀFRONT  
SCREWꢀ‐ꢀHANDLEꢀFRONT  
NUTꢀ‐ꢀHANDLEꢀREAR  
MOTORꢀSUPPORT  
MOTORꢀ‐ꢀMOUNTINGꢀBOLT  
SLEEVE  
12.1  
12.2  
12.3  
13  
13.1  
13.2  
14  
MOTORꢀASSEMBLY  
MOTORꢀ‐ꢀFAN  
FANꢀGUARDꢀ‐ꢀBLACK  
FANꢀGUARDꢀ‐ꢀGRAY  
MOTORꢀBRACKET  
VALVEꢀ‐ꢀGAS  
PRESSUREꢀSWITCH  
VALVEꢀBRACKET  
BASEꢀASSEMBLYꢀ‐ꢀBLACK  
BASEꢀASSEMBLYꢀ‐ꢀGREY  
POWERꢀCORDꢀASSEMBLY  
GASꢀCONNECTORꢀINLET  
CAPACITORꢀ  
14.1  
15  
16  
17  
18  
19  
20  
21  
22  
23  
BASEꢀLOWERꢀ‐BLACK  
BASEꢀLOWERꢀ‐ꢀGREY  
24  
25  
26  
27  
KNOBꢀGASꢀVALVEꢀ‐ꢀBLACK  
KNOBꢀGASꢀVALVEꢀ‐ꢀORANGE  
HEIGHTꢀCONTROLLERꢀ‐ꢀBLACK  
HEIGHTꢀCONTROLLERꢀ‐ꢀGREY  
HEIGHTꢀCONTROLꢀSCREWꢀ‐ꢀBLACK  
HEIGHTꢀCONTROLꢀSCREWꢀ‐ꢀORANGE  
LEADꢀWIREꢀASSEMBLY  
SPARKꢀMODULE  
28  
29  
30  
PCBꢀASSEMBLY  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐ꢀ10FTꢀ(3M)  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐ꢀ10FTꢀ(3M)ꢀw/HANDWHEEL  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ(QCC)ꢀ‐ꢀ10FTꢀ(3M)  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐15FTꢀ(4.6M)  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐15FTꢀ(4.6M)ꢀw/HANDꢀWHEEL  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ(QCC)ꢀ‐ꢀ15FTꢀ(4.6M)  
31  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
* VERSION NOT SHOWN IN EXPLODED VIEW  
15  
PROPANE CONSTRUCTION HEATER  
ProPane construction Heater illustrateD / Parts breaKDoWn  
MODELS: RMC-FA100DGD  
RMC-FA125DGD/LPFA125H  
RMC-FA150DGD  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
16  
PROPANE CONSTRUCTION HEATER  
rePlaceMent Parts list  
PARTꢀNUMBER  
ITEMꢀꢀꢀꢀꢀ  
No.ꢀ  
DESCRIPTION  
QTY  
100ꢀSERIESꢀꢀꢀꢀꢀꢀ 125ꢀSERIESꢀꢀꢀꢀꢀꢀ 150ꢀSERIES  
1
2
3
4
5
6
7
8
9
INNERꢀSHELLꢀASSEMBLY  
NOZZLE  
FLAMEꢀCAP  
THERMALꢀSWITCHꢀBRACKET  
THERMALꢀSWITCHꢀ  
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2304929  
*2304943  
2304930  
2304826  
2201373  
2304578  
2201392  
2304885  
2304946  
N/A  
2304929  
5030077  
2325122  
2315515  
2201373  
2304945  
2206034  
2304885  
2325138  
2305971  
N/A  
2304929  
2304944  
2304931  
2001355  
2201373  
2304945  
2201393  
2304885  
2304947  
N/A  
NOZZLEꢀNUT  
SPARKꢀPLUGꢀASSEMBLY  
THERMOCOUPLEꢀASSEMBLYꢀ(1130/1474ꢁ425L)  
GASꢀTUBINGꢀASSEMBLY  
OUTERꢀSHELLꢀꢁꢀORANGE  
OUTERꢀSHELLꢀꢁꢀBLACK  
N/A  
2315916  
N/A  
N/A  
2315916  
N/A  
10  
2315916  
N/A  
OUTERꢀSHELLꢀꢁꢀGRAY  
OUTERꢀSHELLꢀꢁꢀBLUE  
11  
12  
2101423  
2101447  
2305426  
2001355  
2001077  
2000384  
2304823  
2001332  
2304949  
2304548  
2304936  
2304939  
2305412  
2304938  
5050474  
2305976  
2304624  
2304924  
N/A  
2101673  
2304831  
2301390  
2304926  
N/A  
2101451  
N/A  
2304928  
N/A  
2101423  
2101447  
2305426  
2001355  
2001077  
2000384  
2304823  
2001332  
2304949  
2304548  
2304936  
2304939  
2305412  
2304938  
5051036  
2305976  
2304624  
2304924  
2403354  
2101673  
2304831  
2301390  
2304926  
2403355  
2101451  
2305466  
2304928  
2403356  
2304510  
2305467  
2201371  
2201391  
2201369  
*5055549  
*5055551  
TYQꢁ6D1ꢁ3000  
*5055550  
*5055552  
TYQꢁ6D1ꢁ4572  
2101423  
2101447  
2305426  
2001355  
2001077  
2000384  
2304823  
2001332  
2304949  
2304548  
2304936  
2304939  
2305412  
2304938  
5050475  
2305976  
2304624  
2304924  
N/A  
2101673  
2304831  
2301390  
2304926  
N/A  
2101451  
N/A  
2304928  
N/A  
CORDꢀWRAPꢀ(selectꢀmodelsꢀonly)  
HANDLEꢀASSEMBLYꢀꢁꢀBLACK  
HANDLEꢀASSEMBLYꢀꢁꢀGRAY  
SCREWꢀꢁꢀHANDLEꢀFRONT  
SCREWꢀꢁꢀHANDLEꢀFRONT  
NUTꢀꢁꢀHANDLEꢀREAR  
MOTORꢀSUPPORT  
MOTORꢀꢁꢀMOUNTINGꢀBOLT  
SLEEVE  
12.1  
12.2  
12.3  
13  
13.1  
13.2  
14  
MOTORꢀASSEMBLY  
MOTORꢀꢁꢀFAN  
FANꢀGUARDꢀꢁꢀBLACK  
FANꢀGUARDꢀꢁꢀGRAY  
MOTORꢀBRACKET  
VALVEꢀꢁꢀGAS  
PRESSUREꢀSWITCH  
VALVEꢀBRACKET  
BASEꢀASSEMBLYꢀꢁꢀBLACK  
BASEꢀASSEMBLYꢀꢁꢀGREY  
POWERꢀCORDꢀASSEMBLY  
GASꢀCONNECTORꢀINLET  
CAPACITORꢀ  
14.1  
15  
16  
17  
18  
19  
20  
21  
22  
23  
BASEꢀLOWERꢀꢁꢀBLACK  
BASEꢀLOWERꢀꢁꢀGREY  
24  
25  
26  
27  
KNOBꢀGASꢀVALVEꢀꢁꢀBLACK  
KNOBꢀGASꢀVALVEꢀꢁꢀORANGE  
HEIGHTꢀCONTROLLERꢀꢁꢀBLACK  
HEIGHTꢀCONTROLLERꢀꢁꢀGREY  
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀBLACK  
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀORANGE  
LEADꢀWIREꢀASSEMBLY  
SPARKꢀMODULE  
2304510  
N/A  
2304510  
N/A  
28  
29  
30  
2201371  
2201391  
2201369  
*TYQꢁ6E1ꢁLL38ꢁ00  
*TYQꢁ6D1ꢁLL38ꢁ00  
TYQꢁ6D1ꢁ3000  
*5002785  
*5055548  
TYQꢁ6D1ꢁ4572  
2201371  
2201391  
2201369  
*TYQꢁ6E1ꢁLL38ꢁ00  
N/A  
TYQꢁ6E1ꢁ3000  
*5002785  
N/A  
PCBꢀASSEMBLY  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁꢀ10FTꢀ(3M)  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁꢀ10FTꢀ(3M)ꢀw/HANDWHEEL  
REGꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁꢀ10FTꢀ(3M)  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁ15FTꢀ(4.6M)  
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁ15FTꢀ(4.6M)ꢀw/HANDꢀWHEEL  
REGꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁ15FTꢀ(4.6M)  
31  
TYQꢁ6E1ꢁ4572  
*ꢀVERSIONꢀNOTꢀSHOWNꢀINꢀEXPLODEDꢀVIEW  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
17  
PROPANE CONSTRUCTION HEATER  
ProPane construction Heater illustrateD / Parts breaKDoWn  
MODELS: RMC-FA100/DGP/DGP-01  
RMC-FA125/DGP/DGP-01  
LPFA125DGD  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
18  
PROPANE CONSTRUCTION HEATER  
rePlaceMent Parts list  
PARTꢀNUMBER  
ITEMꢀꢀꢀꢀꢀ  
No.ꢀ  
DESCRIPTION  
QTY  
FA100DGP  
FA125DGP  
LPFA125DGD  
1
2
3
4
5
6
7
8
9
INNERꢀSHELLꢀꢀASSEMBLY  
NOZZLE  
FLAMEꢀCAP  
THERMALꢀSWITCHꢀBRACKET  
THERMALꢀSWITCHꢀ  
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
2304929  
*2304943  
2304930  
2304826  
2201373  
2304578  
2201392  
2304885  
2305975  
2305971  
N/A  
2101423  
2304823  
2001332  
2304949  
2304548  
2304936  
2305412  
N/A  
2304938  
2306000  
2315002  
2301390  
2305976  
2101673  
2304831  
2315001  
2305973  
5051234  
2305999  
2101588  
N/A  
2304929  
5030077  
2325122  
2315515  
2201373  
2304945  
2206034  
2304885  
2325137  
2305971  
N/A  
2101423  
2304823  
2001332  
2304949  
2304548  
2304936  
2305412  
N/A  
2304938  
2306000  
2315002  
2301390  
2305976  
2101673  
2304831  
2315001  
2305973  
5051235  
2305999  
2101588  
N/A  
2304929  
5030077  
2325122  
2315515  
2201373  
2304945  
2206034  
2304885  
2325137  
N/A  
2403443  
2101423  
2304823  
2001332  
2304949  
2304548  
2304936  
N/A  
2304939  
2304938  
2306000  
2315002  
2301390  
2305976  
2101673  
2304831  
2315001  
2305973  
5051235  
2305999  
N/A  
NOZZLEꢀNUT  
SPARKꢀPLUGꢀASSEMBLY  
THERMOCOUPLEꢀASSEMBLYꢀ(1130/1474ꢁ425L)  
GASꢀTUBINGꢀASSEMBLY  
OUTERꢀSHELLꢀꢁꢀORANGE  
OUTERꢀSHELLꢀꢁꢀBLACK  
CORDꢀWRAP  
10  
11  
12  
12.1  
12.2  
13  
MOTORꢀSUPPORT  
MOTORꢀꢁꢀMOUNTINGꢀBOLT  
SLEEVE  
MOTORꢀASSEMBLY  
MOTORꢀꢁꢀFAN  
FANꢀGUARDꢀꢁꢀGRAY  
FANꢀGUARDꢀꢁꢀBLACK  
MOTORꢀBRACKET  
BASEꢀRIGHTꢀSIDE  
LEGꢀHOLDER  
CAPACITORꢀ  
13.1  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
PRESSUREꢀSWITCH  
POWERꢀCORDꢀASSEMBLY  
GASꢀCONNECTORꢀINLET  
BASEꢀBOTTOM  
VALVEꢀBRACKET  
VALVEꢀꢁꢀGAS  
BASEꢀLEFTꢀSIDE  
KNOBꢀGASꢀVALVEꢀꢁꢀORANGE  
KNOBꢀGASꢀVALVEꢀꢁꢀBLACK  
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀORANGE  
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀBLACK  
REGULATORꢀ&ꢀHOSEꢀASSEMBLYꢀꢁꢀ10FTꢀ(3M)  
REGULATORꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁꢀ10FTꢀ(3M)  
REGULATORꢀ&ꢀHOSEꢀASSEMBLYꢀꢁ15FTꢀ(4.6M)  
REGULATORꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁ15FTꢀ(4.6M)  
LEGꢀ  
26  
27  
2101451  
N/A  
2403444  
N/A  
TYQꢁ6D1ꢁ3000  
N/A  
TYQꢁ6D1ꢁ4572  
2305972  
2201371  
2201391  
2201369  
2315003  
NA  
*TYQꢁ6D1ꢁLL38ꢁ00  
N/A  
2315003  
NA  
*TYQꢁ6D1ꢁLL38ꢁ00  
N/A  
28  
*5055548  
N/A  
2305972  
2201371  
2201391  
2201369  
*5055548  
N/A  
2305972  
2201371  
2201391  
2201369  
29  
30  
31  
32  
LEADꢀWIREꢀASSEMBLY  
SPARKꢀMODULE  
PCBꢀASSEMBLY  
*ꢀVERSIONꢀNOTꢀSHOWNꢀINꢀEXPLODEDꢀVIEW  
NEVER LEAVE THE HEATER  
UNATTENDED WHILE BURNING!  
19  
Warranty  
LIMITED WARRANTY:  
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any  
defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either  
provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers  
as directed by GHP Group, Inc., within one (1) year of retail purchase. (Shipping costs, labour costs, etc. are the responsibility of the purchaser.)  
DUTIES OF THE OWNER:  
This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse  
the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled  
check or payment record must be kept to verify purchase date and establish warranty period. Original carton should be kept in case of warranty  
return of unit.  
WHAT IS NOT COVERED:  
1.  
2.  
3.  
4.  
5.  
6.  
Damage resulting from use of improper fuel.  
Damage caused by misuse or use contrary to the owners manual and safety guidelines.  
Damage caused by a lack of normal maintenance.  
Fuses  
Use of non-standard parts or accessories.  
Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.  
This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of  
routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of  
maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM  
GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.  
THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,  
INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE  
REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL  
GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.  
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not  
allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.  
CLAIMS HANDLED AS FOLLOWS:  
1. Contact your retailer and explain the problem.  
2. If the retailer is unable to resolve the problem, contact ourCustomer Service Dept. detailing the heater model, the problem, and proof  
of date of purchase.  
3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative.  
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.  
TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY  
NAME: ______________________________________ PHONE: (  
) __________________ EMAIL: ____________________________  
ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________  
MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________  
DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________  
CITY & STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________  
Please Take a Minute To Give Us Your Answers To The Following Questions.  
All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.  
Who primarily decided this purchase?  
Male  
Female  
18-24  
25-39  
40-59  
60 and over  
Purpose of Purchase? _______________________________________________________________________________________________  
Do you own any other portable heaters? Yes No If yes, type____________________________brand_____________________  
How do you intend to use your new heater?  
How did you become aware of this heater?  
Construction Site  
In-Store Display  
Farm  
Newspaper Ad  
Warehouse/Commercial  
Garage/Outbuilding Other  
Friend/Relative  
Magazine Ad  
TV Commercial  
What made you select this heater?  
Do you: own rent Would you recommend this heater to a friend?  
Store Salesperson Other ___________________________  
Style  
Size/Portability  
Price  
Package  
No  
Brand  
Other ___________________  
Yes  
Please give us your comments:________________________________________________________________________________________  
THANK YOU FOR COMPLETING THIS FORM!  
Information will be held confidential.  
20  
WARRANTY REGISTRATION  
IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14)  
days of date of purchase. You can also register your warranty on the internet at  
for your records.  
GHP Group, Inc.  
6440 W Howard St  
Niles, IL 60714-3302  
Tel: (877) 447-4768  
SAVE THIS CARD!  
Place  
Postage  
Stamp  
Here  
GHP Group, Inc.  
6440 W Howard St  
Niles, IL 60714-3302  

Universal Power Group 12v 2a User Manual
Tekkeon Mypower Go Mp1500 User Manual
Ricoh Aficio Sp 4110sf User Manual
Philips M2922a User Manual
NEC NP62 User Manual
Mitsubishi Motors Automobile Parts V4a51 User Manual
HAMILTON BEACH STACK PRESS 72860 CN User Manual
EMERSON HIGHPOINT CF205BS01 User Manual
BROTHER HL L2340DW 03 User Manual
BLACK DECKER COFFEEMATIC DCM94WH User Manual