PROPANE
CONSTRUCTION HEATER
USER’S MANUAL AND OPERATING INSTRUCTIONS
Dyna-Glo™DELUX RMC-FA40DGD
(40,000 BTU/HR,
FORCED - AIR)
RMC-FA50DGD
RMC-FA60DGD
RMC-FA100DGD
(30,000/50,000 BTU/HR, FORCED - AIR)
(30,000/60,000 BTU/HR, FORCED - AIR)
(70,000/100,000 BTU/HR, FORCED - AIR)
MODELS:
RMC-FA125DGD/LPFA125DGD (70,000/125,000 BTU/HR, FORCED - AIR)
RMC-FA150DGD
(120,000/150,000 BTU/HR, FORCED - AIR)
RMC-FA40/DGP/DGP-01
RMC-FA50/DGP/DGP-01
RMC-FA60/DGP/DGP-01
RMC-FA100/DGP/DGP-01
RMC-FA125/DGP/DGP-01
LPFA125H/LPFA125H-01
RMC-FA150/DGP/DGP-01
(40,000 BTU/HR, FORCED - AIR)
Dyna-Glo™Pro
MODELS:
(30,000/50,000 BTU/HR, FORCED - AIR)
(30,000/60,000 BTU/HR, FORCED - AIR)
(70,000/100,000 BTU/HR, FORCED - AIR)
(70,000/125,000 BTU/HR, FORCED - AIR)
(120,000/150,000 BTU/HR, FORCED - AIR)
FA40DGP-01
C
US
ANS Z83.7-2011 CSA 2.14-2011
adequate ventilation must be provided.
GHP Group, Inc.
6440 w howard St
niles, il 60714-3302
FA60DGP/DGP-01
LPFA125H/H-01
GENERAL HAZARD WARNING
Failure To CoMply wiTh The preCauTionS and inSTruCTionS provided wiTh
ThiS heaTer, Can reSulT in deaTh, SeriouS Bodily injury and properTy loSS,
or daMage FroM The hazardS oF Fire, exploSion, Burn. aSphyxiaTion, CarBon
Monoxide poiSoning, and/or eleCTriCal ShoCk.
only perSonS who Can underSTand and Follow The inSTruCTionS Should
uSe or ServiCe ThiS heaTer.
iF you need aSSiSTanCe or heaTer inForMaTion SuCh aS an inSTruCTion
Manual, laBelS, eTCeTera, ConTaCT The ManuFaCTurer.
CONSUMER: retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
or email us at [email protected]
Printed in China
50-10-104
Rev. 2013-06-05
PROPANE CONSTRUCTION HEATER
TABLE OF CONTENTS
Introduction & Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
• General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
• Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
• Unpacking Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6
• Size & Capacity Of Propane Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
• Installation To The Propane Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
• Refilling The Propane Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
• Leak Checking & Positioning Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
• Lighting & Shutdown Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10
• Test Firing Heater & Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
• Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
• Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 - 13
Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15, 17, 19
propane ConSTruCTion heaTer illuSTraTed / parTS Breakdown:
RMC-FA40, 50 & 60 SeRIeS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
RMC-FA100DGD, RMC-FA125DGD, LPFA125H & RMC-FA150DGD . . . . . . . . . . . . . . . . . . . . . . 16
RMC-FA100DGP/DGP-01, RMC-FA125DGP/DGP-01 & LPFA125DGD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
• Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
: Fire, Burn, inhalaTion, and exploSion hazard, keep Solid
CoMBuSTiBleS, SuCh aS Building MaTerialS, paper or CardBoard, a SaFe
WARNING
diSTanCe away FroM The heaTer aS reCoMMended By The inSTruCTionS.
never uSe The heaTer in SpaCeS whiCh do or May ConTain volaTile or
airBorne CoMBuSTiBleS, or produCTS SuCh aS gaSoline, SolvenTS, painT
ThinnerS, duST parTiCleS or unknown CheMiCalS.
CALIFORNIA PROPOSITION 65: Fuels used in gas or oil fired appliances and the products of
combustion of such fuels, contain chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm. This product contains chemicals, including lead and lead
compounds, known to the State of California to cause cancer, birth defects or other reproductive
harm. Wash hands after handling.
: using this heater in a residential garage requires that the heater is positioned
WARNING
so that it is protected against any possible damage by a moving vehicle, etc. it must be
positioned so that the base of the heater is no less than 18 in (450 mm) above the garage floor or
8 ft (2450 mm) in repair garages. The heater must be placed on a stable surface. Do not place it on
a chair, ladder, etc. raising the heater will reduce BuT noT eliminate the possibility of lighting the
vapor of any flammable liquids which may be improperly stored or accidentally spilled. If the smell of
gasoline is present, do noT operate this heater until the area has been properly ventilated.
WARNING: CONSTRUCTION HEATERS ARE NOT FOR USE IN
GARAGES IN CANADA.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
2
PROPANE CONSTRUCTION HEATER
Dyna-Glo ProPane ForceD air construction Heaters
The heater is designed and approved for use as a construction heater under anS z83.7 CSa 2.14. it is hard
to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY
AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications.
your local authority can advise you about these.
IMPORTANT: read ThiS uSer’S Manual CareFully and CoMpleTely BeFore Trying
To operaTe or ServiCe ThiS heaTer. iMproper uSe oF ThiS heaTer Can CauSe
SeriouS injury or deaTh FroM Fire, exploSion and CarBon Monoxide poiSoning.
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. all the
products of combustion generated by the heater are forced through the heater and released into the area being
heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount
of carbon monoxide. humans can tolerate small amounts of carbon monoxide for short periods. Carbon
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning
or death.
: noT For uSe wiTh duCT work.
WARNING
sPeciFications
ModelꢀNo.
RMC‐FA40DGP/
DGP‐01
FA50ꢀSeries
FA60ꢀSeries
RMC‐FA100DGD/
DGP/DGP‐01
LPFA125DGD/
RMC‐FA125DGP/
DGP‐01
LPFA125H/
RMC‐FA125DGD
RMC‐FA150DGD
30,000ꢀBTU/hr
50,000ꢀBTU/hr
30,000ꢀBTU/hr
60,000ꢀBTU/hr
70,000ꢀBTU/hr
100,000ꢀBTU/hr
70,000ꢀBTU/hr
125,000ꢀBTU/hr
70,000ꢀBTU/hr
125,000ꢀBTU/hr
120,000ꢀBTU/hr
150,000ꢀBTU/hr
InputꢀRating
TypeꢀofꢀGas
40,000ꢀBTU/hr
Propane
Propane
Propane
Propane
Propane
Propane
Propane
GasꢀSupplyꢀPressureꢀtoꢀ
RegulatorꢀMaximum
CylinderꢀPressure
5psig
CylinderꢀPressure
CylinderꢀPressure
CylinderꢀPressure
CylinderꢀPressure
CylinderꢀPressure
CylinderꢀPressure
Minimumꢀ(forꢀpurposeꢀofꢀ
InputꢀAdjustment)
5psig
5psig
5psig
5psig
5psig
5psig
ManifoldꢀPressure
GasꢀConsumption
ElectricalꢀInput
11"ꢀW.C
11"ꢀW.C
11"ꢀW.C
11"ꢀW.C
11"ꢀW.C
11"ꢀW.C
11"ꢀW.C
1.4lbs/hr
2.3lbs/hr
1.4lbs/hr
2.8lbs/hr
3.3lbs/hr
4.6lbs/hr
3.3lbs/hr
5.8lbs/hr
3.3lbs/hr
5.8lbs/hr
5.6lbs/hr
7.0lbs/hr
1.9lbs/hr
120V,ꢀ60Hz,ꢀ1Øꢀ
0.68amps
120V,ꢀ60Hz,ꢀ1Øꢀ
0.65amps
120V,ꢀ60Hz,ꢀ1Øꢀ
0.65amps
120V,ꢀ60Hz,ꢀ1Øꢀ
0.7amps
120V,ꢀ60Hz,ꢀ1Øꢀ
0.7amps
120V,ꢀ60Hz,ꢀ1Øꢀ
0.7amps
120V,ꢀ60Hz,ꢀ1Øꢀ
0.7amps
Amperage ꢀꢀLoad
ꢀꢀUnload
ꢀꢀLoad
3550rpm
3000rpm
3570rpm
3300rpm
3570rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
Fan
Ignition
Piezo/ManualꢀSpark
0.16"ꢀ(4mm)
ContinuousꢀSpark
0.16"ꢀ(4mm)
ContinuousꢀSpark
0.16"ꢀ(4mm)
ContinuousꢀSpark
0.16"ꢀ(4mm)
ContinuousꢀSpark
0.16"ꢀ(4mm)
ContinuousꢀSpark
0.16"ꢀ(4mm)
ContinuousꢀSpark
0.11"ꢀ(2.8mm)
SparkꢀGap
25.6"x12.7"x15.6"
(650x323x396)mm
25.6"x11.8"x16.1"
(650x300x409)mm
26.6"x13.0"x17.3"
(676x330x439)mm
25.6"x11.8"x16.1"
(650x300x409)mm
26.2"x11.5"x17.2"
(666x292x436)mm
25.6"x12.7"x15.6"
(650x323x396)mm
19.3"x8.3"x15.2"
(490x211x386)mm
19.3"x8.3"x15.2"
(490x211x386)mm
19.3"x8.3"x15.2"
(490x211x386)mm
25.6"x11.8"x16.1"
(650x300x409)mm
Sizeꢀ(LxWxH)
Weight
13.7lbs/14lbs
(6.2kg/6.35kg)
21.5lbs/21lbs/20.8lbs
(9.75kg/9.5kg/9.4kg)
21.9lbs/21lbs/20.8lbs
(9.9kg/9.5kg/9.4kg)
20.3lbs/21.5lbs
(21.9kg/9.75kg)
14.3lbsꢀ(6.48kg)
14.3lbsꢀ(6.48kg)
21.2lbsꢀ(9.6kg)
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
3
PROPANE CONSTRUCTION HEATER
General saFety instruction
accidents are always tragic especially because so many of them could have been prevented with little care
and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.
iMPortant saFety instruction
• Children should be carefully supervised, when they are in the area.
• Always maintain proper clearance from combustible materials. Minimum clearance from combustibles:
Side - 24” (61cm); Top - 36” (91cm); Front - 72” (1.8M). Floor - combustible. Not for use on finished floors.
• Heater must be placed on level and stable surface.
• Never place anything including clothes or other flammable items on the heater.
• The appliance area shall be kept clear and free from combustible materials, gasoline and other flammable
vapours and liquids.
• Do not modify or operate a heater which has been modified.
• Adequate clearance for accessibility and for combustion & ventilation air supply must be maintained at all
times when the heater is operating.
• Service and repair should be done by a qualified service person. The heater should be inspected
before each use and at least annually by a qualified person. More frequent cleaning may be required as
necessary. do not service while hot or operating.
• Never connect heater to an unregulated gas supply.
• The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only,
do not convert heater to any other gas. installation must conform to local codes or, in the absence of local
codes, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the
Natural Gas and Propane Installation Code CSA B149.1
• The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure,
respectively. use only the regulator & hose assembly provided with the heater. inspect the regulator/hose
assembly prior to each use of the heater. if there is excessive abrasion or wear, or hose is cut, replace with
regulator/hose assembly listed on the parts list prior to using this heater.
• Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame
to check for gas leaks.
• The electrical connection & grounding must comply with National electrical Code. ANSI/NFPA 70 or in
Canada CSa C22.1, Canadian electrical Code, part 1. use only a properly grounded three
(3) prong receptacle.
• Do not restrict inlet or outlet by any means. The flow of combustion and ventilation air is not to be obstructed.
• This heater should not be directed toward any propane-gas container within 20 ft (6M). The heater must be
located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container.
• The propane cylinder supply system must be arranged to provide for vapour withdrawal from the
operating cylinder.
• This heater is not to be used with external thermostats, timers or other devices that control or alter electrical
supply to the heater.
: Motor and fan must be running before lighting, during operation and at shutdown,
in order to prevent a flame-out condition which could result in personal injury or property damage.
WARNING
ProDuct Features
• Portable & Stable
• 100% Safety Shutoff System
• Continuous Adjustable Input Ratings
(except FA40)
• Wind Resistant & Rain Protected
• Continuous Spark Ignition or
Piezo electric Spark Ignition
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
4
PROPANE CONSTRUCTION HEATER
unPacKinG Heater
1. remove heater from carton.
2. Remove all protective packing applied to heater for shipment.
3. Retain cartons and packaging material until unit is operated and found in good condition.
4. Check heater for any shipping damage. If heater shows any external or internal
damage, promptly inform dealer/distributor where you purchased heater.
Assembly Components and Instructions for Steel Base Units:
Contents:
Tools required for assembly:
All Models: adjustable wrench
FA100 - FA150: phillips head
Screw driver
Assembly Time:
5 Minutes
All Models: unit, Manual, hose and regulator
assembly
FA100 - FA150 Series Includes:
2 Cord Wrap Attachments, 4 Screws (ST3.5x10)
1. Assembling the Cord Wrap Attachments:
(FA100 - FA150 Series Only)
Parts Required:
4 Screws (ST3.5x10),
and 2 Cord wrap attachments
place the cord wrap attachment
as shown, then use phillips
screwdriver to tighten the
screws and secure the
cord wrap attachments.
2. Regulator and Hose Connection:
(All Models)
See figure on right.
Connect the hose tightly to
the heater using a wrench.
please also refer to
page 8 in the manual.
hose assembly
Tighten, clockwise,
use a wrench
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
5
PROPANE CONSTRUCTION HEATER
Assembly Components and Instructions for Plastic Base Units:
Contents:
Tools required for assembly:
All Models: adjustable wrench
FA125 Series: phillips head
Screw driver
Assembly Time:
5 Minutes
All Models: unit, Manual, hose and regulator
assembly, adjustable leg, 2 height Control Screws
FA125 Series Includes:
2 Cord Wrap Attachments, 4 Screws (ST3.5x10)
1. Assemble the Leg:
Parts Required: adjustable leg
place the heater as shown,
insert the leg into holes of
the base, then adjust
to the desired height.
2. Assemble the Height Control Screw:
Parts Required: height Control Screw 2 pcs
Turn the height Control Screw
clockwise to lock it. Turn the
height Control Screw counter-
clockwise to unlock it.
Lock, clockwise
3. Assembling the Cord Wrap Attachments:
Parts Required: 4 Screws (ST3.5X10)
and 2 Cord wrap attachments
place the cord wrap attachments
as shown, then use phillips
screwdriver to tighten the screws
and secure the cord wrap attachments.
4. Regulator and Hose Connection:
hose assembly
See figure on right.
Connect the hose tightly to
the heater using a wrench.
please also refer to
Tighten, clockwise,
page 8 in the manual.
use a wrench
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
6
PROPANE CONSTRUCTION HEATER
inForMation on siZe * caPacity oF ProPane Gas cylinDers:
The chart below shows the number and size of propane tanks needed to run this heater.
*Less gas is vaporized at lower temperatures.
You may need two or more 100 pound tanks or one larger tank in colder weather.
(See the parts list for your model of heater to get the specified regulator assembly.)
Number of Tanks
Temperature
100,000 -
(°F) At tank
40,000-60,000 BTu/h
150,000 BTU/h
125,000 BTU/h
above 32°F
1 - 20lb
1 - 20lb
2 - 100lb
2 - 100lb
2 - 100lb
32°F
2 - 100lb
20°F
10°F
-10°F
-20°F
1 - 20lb
1 - 20lb
2 - 20lb
1 - 100lb
2 - 100lb
3 - 100lb
3 - 100lb
3 - 100lb
Use Larger Tank
Use Larger Tank
Use Larger Tank
Use Larger Tank
The propane (LP) gas tank must also be equipped with the following:
• A collar to protect the Propane gas valve.
• A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the
american national Standards for Compressed gas Cylinder valve outlets and inlet
Connections.
• A safety relief valve having direct communications with the vapor space of the tank.
• An arrangement of vapor withdrawal.
The propane (LP) gas pressure regulator and hose assembly supplied with
this heater must be used without alteration.
The hose assembly shall be visually inspected prior to each use of the heater. if it is evident
that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the
heater being put into operation. The replacement hose assembly shall be that specified
by the manufacturer.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
7
PROPANE CONSTRUCTION HEATER
installation to tHe ProPane Gas tanK
IMPORTANT: you must use a propane/lp gas supply cylinder that is compatible with the connection device
provided with the hose and regulator.
regulator
propane/lp
Supply valve
propane/lp
Tank
Fuel gas
Fitting
hose to
heater
hose to regulator
hose Fitting
Connector inlet
FIGURE 2
FIGURE 3
FIGURE 1
1. Provide propane/LP supply system. ensure that the valve on the cylinder is fully closed by turning the knob
fully clockwise ( ). ensure that the cylinder is fully upright for vapor withdrawl. (see size/capacity, page 7).
2. Connect hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.
3. Connect fuel gas fitting hose/regulator assembly to propane LP tank(s).
3a. For units with a POL fitting (see figure 1) turn fuel fitting counterclockwise into threads on tank. Tighten
firmly using a wrench. Some models have a hand wheel that can be used to tighten the fitting. This hand
wheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT:
Position regulator so that hose leaving the regulator is in a horizontal position.
3b. For units with a QCC fitting (see figure 2) turn QCC gas fitting clockwise onto threads on tank. Tighten
firmly using your hand (DO NOT USe A WReNCH). IMPORTANT: Position regulator so that the regulator
vent is pointing down toward the floor and the arrow on the regulator is visible.
4. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTe: If not opened slowly, excess flow
device in regulator may stop gas flow. If this happens, close propane/LP supply valve, wait one minute
(or until you hear a click) and open again slowly.
5. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints.
Bubbles forming show a leak that must be corrected.
6. Close propane / lp supply valve before attempting to repair connection.
: Purging and filling of LP gas tanks must be performed by personnel who
has been thoroughly trained in accepted lp gas industry procedures. Failure to follow
WARNING
these instructions may result in explosion, fire, severe personal injury, or death.
reFillinG tHe ProPane Gas tanK
ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
• Turn heater gas valve knob and gas tank valve to OFF position.
• Propane tank valve equipped with the old style fitting has LeFT HANDeD THReADS. Turn POL fitting
CLOCKWISe to loosen. Protect POL fitting when disconnected from tank.
• Have tank filled by your local Propane gas supplier.
• Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTeRCLOCKWISe.
• With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks
with soap solution.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
8
PROPANE CONSTRUCTION HEATER
ProPane saFety
Propane is safe to use when properly handled. Careless handling of the Propane gas tank could
result in fire and/or an explosion. Therefore:
• Always keep tank/cylinder securely fastened in an upright position.
• Avoid tipping tank on its side when connected to a regulator since this may cause damage to
diaphragm in regulator.
• Handle valves with care.
• Never connect an unregulated Propane tank to construction heater.
• Do not subject Propane tank to excessive heat.
• Tightly close the gas shutoff valve on the Propane tank after each use.
• The POL fitting must be protected when disconnected from the propane tank.
• Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance.
THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING, GARAGE
OR ANY OTHER ENCLOSED AREA.
leaK cHecKinG
Check all gas connections with a soap solution to be sure they are tight and leak proof.
• The installation of your heater must meet all local codes and/or gas utility requirements or, in the
absence of local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA
58 and the Natural and Propane Installation Code, CSA B149.1.
• The minimum clearances to combustible construction: Side - 24” (61cm); Top - 36” (91cm);
Front - 72” (1.8M); Floor - combustible, must be maintained at all times.
• The hose assembly should be visually inspected prior to each use of the heater. If it is evident that
there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being
put into operation.
• The replacement hose assembly shall be that specified by the manufacturer (Refer to parts list).
liGHtinG instructions
: Motor and fan must be running before lighting, during operation and shutdown, in
WARNING
order to prevent a flame-out condition which could result in personal injury or property damage.
NOTE: This heater uses a continuous spark ignition system. This unit will continue to make a clicking/
ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob
positioning.
1. Connect power cord to a properly grounded three (3) prong 120V, 60Hz, single phase receptacle.
2. Turn gas valve knob clockwise
3. Wait five (5) minutes to clear any gas. Then smell for gas, if you don’t smell gas, go to next step.
4. Turn gas supply ON by turning Propane tank valve counterclockwise
5. Push in and turn gas control knob counterclockwise to “LOW/IGN”. This will light the burner. If
to OFF position.
.
needed, keep pressing control knob until the burner lights and keep depressing and turning from
OFF to LOW/IGN on Piezo electric spark models. (“HIGH/IGN”: In case of FA40 series)
6. Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds
release valve knob.
7. if burner does not stay lit, repeat the lighting procedure.
8. When burner is lit, turn gas valve knob counterclockwise
FA40 series).
to desired setting. (All models, except
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
9
PROPANE CONSTRUCTION HEATER
sHutDoWn instructions
: Motor and fan must be running before lighting, during operation and at shutdown,
in order to prevent a flame-out condition which could result in personal injury or property damage.
WARNING
Turn gas valve knob clockwise
to OFF position.
Turn gas supply OFF by turning Propane tank valve clockwise
to close.
disconnect the power cord once the heater has cooled to ambient temperature.
test FirinG Heater
Test fire your construction heater, following the lighting instructions applicable to the gas control sys-
tem employed. Leak test all gas connections with soap solution. Soap bubbles indicate gas leakage.
DO NOT use a match or flame to test for gas leaks.
storaGe
Never store a Propane gas tank inside a building or in the vicinity of any gas or oil burning appliance.
When the Propane tank is not disconnected from the construction heater, the gas tank and heater
must be stored outdoors in a well ventilated area, out of the reach of children. if for any reason the
heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well ventilated
area out of reach of children, in accordance with the standard for the the Storage and handling of
Liquefied Petroleum Gases, ANSI / NFPA 58 and CSA B149.1, Natural Gas and Propane Installation
Code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is
disconnected from the heater.
Maintenance instructions
1. Turn unit off, allow heater to fully cool and disconnect propane hose before performing any Mainte-
nance
functions. unplug the unit from the 120v receptacle.
2. Keep unit clean and keep the inside of the torpedo housing debris free.
3. Have unit checked by a qualified technician at least once a year, preferably prior to the heating
season.
rePlaceMent Parts
Warning: Use only original replacement
parts. This Heater must use design-specific
parts. Do not substitute or use generic parts.
Improper replacement parts could cause
serious or fatal injuries.
when calling ghp group inc., have ready:
•
•
•
•
•
•
your name
your address
how heater was malfunctioning
serial number of heater
model number of heater
replacement part number
This will also protect your warranty coverage
for parts replaced under warranty.
parts warranty and non-warranty: Contact au-
thorized dealers of this product. If they can not
supply original replacement part(s), either con-
tact your nearest parts Central or ghp group
inc., Technical Service department at 1-877-
447-4768.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
10
PROPANE CONSTRUCTION HEATER
troublesHootinG
PROBLEM
POSSIBLEꢀCAUSE
CORRECTIVEꢀACTION
1. Controlꢀdialꢀisꢀoffꢀandꢀunitꢀis
clicking/4cking
1. Thisꢀheaterꢀusesꢀaꢀcon4nuousꢀspark
igni4onꢀsystem.ꢀThisꢀunitꢀwillꢀcon4nue
toꢀmakeꢀaꢀclicking/4ckingꢀsoundꢀatꢀall
4mesꢀbeforeꢀigni4on,ꢀaAerꢀigni4on
andꢀduringꢀopera4on,ꢀregardlessꢀof
valveꢀknobꢀposi4oning.
1. Noꢀcorrec4veꢀac4onꢀisꢀneeded.
2. Theꢀunitꢀisꢀ4cking/clickingꢀ
whileꢀtheꢀheaterꢀisꢀlit.
1. Thisꢀheaterꢀusesꢀaꢀcon4nuousꢀspark
igni4onꢀsystem.ꢀThisꢀunitꢀwillꢀcon4nue
toꢀmakeꢀaꢀclicking/4ckingꢀsoundꢀatꢀall
4mesꢀbeforeꢀigni4on,ꢀaAerꢀigni4on
andꢀduringꢀopera4on,ꢀregardlessꢀof
valveꢀknobꢀposi4oning.
1. Noꢀcorrec4veꢀac4onꢀisꢀneeded.
3. Fanꢀdoesꢀnotꢀturnꢀwhen
electricalꢀconnec4onꢀisꢀmade.
1. Noꢀelectricꢀpowerꢀtoꢀheater.
1. Checkꢀcurrentꢀtoꢀelectricꢀoutlet.ꢀIfꢀvoltageꢀisꢀcorrect,
checkꢀpowerꢀcordꢀandꢀextensionꢀcordꢀfor
2. Fanꢀbladeꢀcontactsꢀinsideꢀofꢀheaterꢀhousing. 2. Beꢀsureꢀthatꢀhousingꢀisꢀnotꢀdamaged.ꢀMakeꢀsure
thereꢀareꢀnoꢀobstruc4onsꢀtoꢀtheꢀfan.
3. Fanꢀblade(s)ꢀbent
4. Fanꢀmotorꢀdefec4ve.
3. Straightenꢀblade(s)ꢀtoꢀmatchꢀothers.
4. Replaceꢀmotor.
4. Heaterꢀwillꢀnotꢀfire.
1. Noꢀsparkꢀatꢀignitor.
1. Checkꢀignitorꢀwire.ꢀReꢁaQachꢀorꢀ4ghtenꢀifꢀloose.
CheckꢀSparkꢀmodule.ꢀReplaceꢀifꢀnecessary.
2. Setꢀgapꢀ(Seeꢀspecifica4onsꢀforꢀgap).ꢀ
3. ReplaceꢀSparkꢀPlug.
2. Improperꢀsparkꢀgap.
3. Badꢀelectrode.
5. Heaterꢀquitsꢀwhile
running.
1. Internalꢀtemperatureꢀtooꢀhighꢀcausingꢀlimitꢀ
switchꢀtoꢀshutꢀdownꢀopera4on.
1. Ifꢀtheꢀheatersꢀoutputꢀisꢀrestricted,ꢀinternalꢀtemperature
becomesꢀtooꢀhigh.ꢀMoveꢀheaterꢀawayꢀfrom
anyꢀobstruc4ons.
2. DamagedꢀControlꢀValve.
2. ReplaceꢀControlꢀValve.
3. Dustꢀorꢀdebrisꢀbuildꢁupꢀinsideꢀofꢀheater.
3. Cleanꢀinsideꢀofꢀheater.
Always be sure to follow proper maintenance procedures, by cleaning the heater once per
month during regular usage, and check spark gap at least once per season.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
11
PROPANE CONSTRUCTION HEATER
WirinG DiaGraMs
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
12
PROPANE CONSTRUCTION HEATER
WirinG DiaGraMs
*100K,125K & 150K Models only
*100K,125K & 150KSólo modelos
*100K,125K & 150K Les modèles Seulement
*
* *
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
13
PROPANE CONSTRUCTION HEATER
rePlaceMent Parts list
MODELS: FA40 Series
FA50 Series
FA60 Series
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
14
PROPANE CONSTRUCTION HEATER
rePlaceMent Parts list
PARTꢀNUMBER
ITEMꢀNo.ꢀ
DESCRIPTION
QTY
40ꢀSERIES
50ꢀSERIES
60ꢀSERIES
1
2
3
4
5
6
7
8
9
INNERꢀSHELLꢀꢀASSEMBLY
NOZZLE
FLAMEꢀCAP
THERMALꢀSWITCHꢀBRACKET
THERMALꢀSWITCHꢀ
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2304818
*2304829
2304819
2304826
2201373
2304578
2201375
2304885
2304830
2305403
2315915
2315956
2315312
N/A
2101447
2305426
2001355
2001077
2000384
2304823
2001332
2304949
2305909
2304821
2304828
2305411
2304937
5050200
N/A
2304624
2304923
2305405
2201368
2304831
2201372
2304925
2305407
2101451
2305466
2304927
2305409
2304510
2305467
2201371
N/A
2201369
*5002199
*5002540
TYQ‐9C‐3000
*5055297
*5055414
TYQ‐9C‐4572
2304818
*2304942
2304819
2304826
2201563
2304578
2201375
2304885
2304830
2305403
2315915
2315956
2315312
N/A
2101447
2305426
2001355
2001077
2000384
2304823
2001332
2304949
2305447
2304821
2304828
2305411
2304937
5050510
N/A
2304624
2304923
2305405
2101670
2304831
2201372
2304925
2305407
2101451
2305466
2304927
2305409
2304510
2305467
2201371
2201391
2201369
*5002614
*5055533
TYQ‐10C‐3000
*5055298
*5055415
TYQ‐10C‐4572
2304818
*2325121
2325120
2304826
2201599
2304578
2206033
2304885
2304830
2305403
2315915
2315956
2315312
N/A
2101447
2305426
2001355
2001077
2000384
2304823
2001332
2304949
2304547
2304821
2304828
2305411
2304937
5051033
N/A
2304624
2304923
2305405
2101670
2304831
2201372
2304925
2305407
2101451
2305466
2304927
2305409
2304510
2305467
2201371
2201391
2201369
*5002614
*5055533
TYQ‐10C‐3000
*5055298
*5055415
TYQ‐10C‐4572
NOZZLEꢀNUT
SPARKꢀPLUGꢀASSEMBLY
THERMOCOUPLEꢀASSEMBLYꢀ(1130/1474‐425L)
GASꢀTUBINGꢀASSEMBLY
OUTERꢀSHELLꢀ‐ꢀORANGE
OUTERꢀSHELLꢀ‐ꢀBLACK
10
OUTERꢀSHELLꢀ‐ꢀGRAY
OUTERꢀSHELLꢀ‐ꢀBLUE
11
12
CORDꢀWRAPꢀ(selectꢀmodelsꢀonly)
HANDLEꢀASSEMBLYꢀ‐ꢀBLACK
HANDLEꢀASSEMBLYꢀ‐ꢀGRAY
SCREWꢀ‐ꢀHANDLEꢀFRONT
SCREWꢀ‐ꢀHANDLEꢀFRONT
NUTꢀ‐ꢀHANDLEꢀREAR
MOTORꢀSUPPORT
MOTORꢀ‐ꢀMOUNTINGꢀBOLT
SLEEVE
12.1
12.2
12.3
13
13.1
13.2
14
MOTORꢀASSEMBLY
MOTORꢀ‐ꢀFAN
FANꢀGUARDꢀ‐ꢀBLACK
FANꢀGUARDꢀ‐ꢀGRAY
MOTORꢀBRACKET
VALVEꢀ‐ꢀGAS
PRESSUREꢀSWITCH
VALVEꢀBRACKET
BASEꢀASSEMBLYꢀ‐ꢀBLACK
BASEꢀASSEMBLYꢀ‐ꢀGREY
POWERꢀCORDꢀASSEMBLY
GASꢀCONNECTORꢀINLET
CAPACITORꢀ
14.1
15
16
17
18
19
20
21
22
23
BASEꢀLOWERꢀ‐BLACK
BASEꢀLOWERꢀ‐ꢀGREY
24
25
26
27
KNOBꢀGASꢀVALVEꢀ‐ꢀBLACK
KNOBꢀGASꢀVALVEꢀ‐ꢀORANGE
HEIGHTꢀCONTROLLERꢀ‐ꢀBLACK
HEIGHTꢀCONTROLLERꢀ‐ꢀGREY
HEIGHTꢀCONTROLꢀSCREWꢀ‐ꢀBLACK
HEIGHTꢀCONTROLꢀSCREWꢀ‐ꢀORANGE
LEADꢀWIREꢀASSEMBLY
SPARKꢀMODULE
28
29
30
PCBꢀASSEMBLY
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐ꢀ10FTꢀ(3M)
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐ꢀ10FTꢀ(3M)ꢀw/HANDWHEEL
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ(QCC)ꢀ‐ꢀ10FTꢀ(3M)
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐15FTꢀ(4.6M)
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ‐15FTꢀ(4.6M)ꢀw/HANDꢀWHEEL
REGꢀ&ꢀHOSEꢀASSEMBLYꢀ(QCC)ꢀ‐ꢀ15FTꢀ(4.6M)
31
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
* VERSION NOT SHOWN IN EXPLODED VIEW
15
PROPANE CONSTRUCTION HEATER
ProPane construction Heater illustrateD / Parts breaKDoWn
MODELS: RMC-FA100DGD
RMC-FA125DGD/LPFA125H
RMC-FA150DGD
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
16
PROPANE CONSTRUCTION HEATER
rePlaceMent Parts list
PARTꢀNUMBER
ITEMꢀꢀꢀꢀꢀ
No.ꢀ
DESCRIPTION
QTY
100ꢀSERIESꢀꢀꢀꢀꢀꢀ 125ꢀSERIESꢀꢀꢀꢀꢀꢀ 150ꢀSERIES
1
2
3
4
5
6
7
8
9
INNERꢀSHELLꢀASSEMBLY
NOZZLE
FLAMEꢀCAP
THERMALꢀSWITCHꢀBRACKET
THERMALꢀSWITCHꢀ
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2304929
*2304943
2304930
2304826
2201373
2304578
2201392
2304885
2304946
N/A
2304929
5030077
2325122
2315515
2201373
2304945
2206034
2304885
2325138
2305971
N/A
2304929
2304944
2304931
2001355
2201373
2304945
2201393
2304885
2304947
N/A
NOZZLEꢀNUT
SPARKꢀPLUGꢀASSEMBLY
THERMOCOUPLEꢀASSEMBLYꢀ(1130/1474ꢁ425L)
GASꢀTUBINGꢀASSEMBLY
OUTERꢀSHELLꢀꢁꢀORANGE
OUTERꢀSHELLꢀꢁꢀBLACK
N/A
2315916
N/A
N/A
2315916
N/A
10
2315916
N/A
OUTERꢀSHELLꢀꢁꢀGRAY
OUTERꢀSHELLꢀꢁꢀBLUE
11
12
2101423
2101447
2305426
2001355
2001077
2000384
2304823
2001332
2304949
2304548
2304936
2304939
2305412
2304938
5050474
2305976
2304624
2304924
N/A
2101673
2304831
2301390
2304926
N/A
2101451
N/A
2304928
N/A
2101423
2101447
2305426
2001355
2001077
2000384
2304823
2001332
2304949
2304548
2304936
2304939
2305412
2304938
5051036
2305976
2304624
2304924
2403354
2101673
2304831
2301390
2304926
2403355
2101451
2305466
2304928
2403356
2304510
2305467
2201371
2201391
2201369
*5055549
*5055551
TYQꢁ6D1ꢁ3000
*5055550
*5055552
TYQꢁ6D1ꢁ4572
2101423
2101447
2305426
2001355
2001077
2000384
2304823
2001332
2304949
2304548
2304936
2304939
2305412
2304938
5050475
2305976
2304624
2304924
N/A
2101673
2304831
2301390
2304926
N/A
2101451
N/A
2304928
N/A
CORDꢀWRAPꢀ(selectꢀmodelsꢀonly)
HANDLEꢀASSEMBLYꢀꢁꢀBLACK
HANDLEꢀASSEMBLYꢀꢁꢀGRAY
SCREWꢀꢁꢀHANDLEꢀFRONT
SCREWꢀꢁꢀHANDLEꢀFRONT
NUTꢀꢁꢀHANDLEꢀREAR
MOTORꢀSUPPORT
MOTORꢀꢁꢀMOUNTINGꢀBOLT
SLEEVE
12.1
12.2
12.3
13
13.1
13.2
14
MOTORꢀASSEMBLY
MOTORꢀꢁꢀFAN
FANꢀGUARDꢀꢁꢀBLACK
FANꢀGUARDꢀꢁꢀGRAY
MOTORꢀBRACKET
VALVEꢀꢁꢀGAS
PRESSUREꢀSWITCH
VALVEꢀBRACKET
BASEꢀASSEMBLYꢀꢁꢀBLACK
BASEꢀASSEMBLYꢀꢁꢀGREY
POWERꢀCORDꢀASSEMBLY
GASꢀCONNECTORꢀINLET
CAPACITORꢀ
14.1
15
16
17
18
19
20
21
22
23
BASEꢀLOWERꢀꢁꢀBLACK
BASEꢀLOWERꢀꢁꢀGREY
24
25
26
27
KNOBꢀGASꢀVALVEꢀꢁꢀBLACK
KNOBꢀGASꢀVALVEꢀꢁꢀORANGE
HEIGHTꢀCONTROLLERꢀꢁꢀBLACK
HEIGHTꢀCONTROLLERꢀꢁꢀGREY
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀBLACK
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀORANGE
LEADꢀWIREꢀASSEMBLY
SPARKꢀMODULE
2304510
N/A
2304510
N/A
28
29
30
2201371
2201391
2201369
*TYQꢁ6E1ꢁLL38ꢁ00
*TYQꢁ6D1ꢁLL38ꢁ00
TYQꢁ6D1ꢁ3000
*5002785
*5055548
TYQꢁ6D1ꢁ4572
2201371
2201391
2201369
*TYQꢁ6E1ꢁLL38ꢁ00
N/A
TYQꢁ6E1ꢁ3000
*5002785
N/A
PCBꢀASSEMBLY
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁꢀ10FTꢀ(3M)
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁꢀ10FTꢀ(3M)ꢀw/HANDWHEEL
REGꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁꢀ10FTꢀ(3M)
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁ15FTꢀ(4.6M)
REGꢀ&ꢀHOSEꢀASSEMBLYꢀꢁ15FTꢀ(4.6M)ꢀw/HANDꢀWHEEL
REGꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁ15FTꢀ(4.6M)
31
TYQꢁ6E1ꢁ4572
*ꢀVERSIONꢀNOTꢀSHOWNꢀINꢀEXPLODEDꢀVIEW
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
17
PROPANE CONSTRUCTION HEATER
ProPane construction Heater illustrateD / Parts breaKDoWn
MODELS: RMC-FA100/DGP/DGP-01
RMC-FA125/DGP/DGP-01
LPFA125DGD
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
18
PROPANE CONSTRUCTION HEATER
rePlaceMent Parts list
PARTꢀNUMBER
ITEMꢀꢀꢀꢀꢀ
No.ꢀ
DESCRIPTION
QTY
FA100DGP
FA125DGP
LPFA125DGD
1
2
3
4
5
6
7
8
9
INNERꢀSHELLꢀꢀASSEMBLY
NOZZLE
FLAMEꢀCAP
THERMALꢀSWITCHꢀBRACKET
THERMALꢀSWITCHꢀ
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
2304929
*2304943
2304930
2304826
2201373
2304578
2201392
2304885
2305975
2305971
N/A
2101423
2304823
2001332
2304949
2304548
2304936
2305412
N/A
2304938
2306000
2315002
2301390
2305976
2101673
2304831
2315001
2305973
5051234
2305999
2101588
N/A
2304929
5030077
2325122
2315515
2201373
2304945
2206034
2304885
2325137
2305971
N/A
2101423
2304823
2001332
2304949
2304548
2304936
2305412
N/A
2304938
2306000
2315002
2301390
2305976
2101673
2304831
2315001
2305973
5051235
2305999
2101588
N/A
2304929
5030077
2325122
2315515
2201373
2304945
2206034
2304885
2325137
N/A
2403443
2101423
2304823
2001332
2304949
2304548
2304936
N/A
2304939
2304938
2306000
2315002
2301390
2305976
2101673
2304831
2315001
2305973
5051235
2305999
N/A
NOZZLEꢀNUT
SPARKꢀPLUGꢀASSEMBLY
THERMOCOUPLEꢀASSEMBLYꢀ(1130/1474ꢁ425L)
GASꢀTUBINGꢀASSEMBLY
OUTERꢀSHELLꢀꢁꢀORANGE
OUTERꢀSHELLꢀꢁꢀBLACK
CORDꢀWRAP
10
11
12
12.1
12.2
13
MOTORꢀSUPPORT
MOTORꢀꢁꢀMOUNTINGꢀBOLT
SLEEVE
MOTORꢀASSEMBLY
MOTORꢀꢁꢀFAN
FANꢀGUARDꢀꢁꢀGRAY
FANꢀGUARDꢀꢁꢀBLACK
MOTORꢀBRACKET
BASEꢀRIGHTꢀSIDE
LEGꢀHOLDER
CAPACITORꢀ
13.1
14
15
16
17
18
19
20
21
22
23
24
25
PRESSUREꢀSWITCH
POWERꢀCORDꢀASSEMBLY
GASꢀCONNECTORꢀINLET
BASEꢀBOTTOM
VALVEꢀBRACKET
VALVEꢀꢁꢀGAS
BASEꢀLEFTꢀSIDE
KNOBꢀGASꢀVALVEꢀꢁꢀORANGE
KNOBꢀGASꢀVALVEꢀꢁꢀBLACK
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀORANGE
HEIGHTꢀCONTROLꢀSCREWꢀꢁꢀBLACK
REGULATORꢀ&ꢀHOSEꢀASSEMBLYꢀꢁꢀ10FTꢀ(3M)
REGULATORꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁꢀ10FTꢀ(3M)
REGULATORꢀ&ꢀHOSEꢀASSEMBLYꢀꢁ15FTꢀ(4.6M)
REGULATORꢀ&ꢀHOSEꢀASSEMBLY(QCC)ꢀꢁ15FTꢀ(4.6M)
LEGꢀ
26
27
2101451
N/A
2403444
N/A
TYQꢁ6D1ꢁ3000
N/A
TYQꢁ6D1ꢁ4572
2305972
2201371
2201391
2201369
2315003
NA
*TYQꢁ6D1ꢁLL38ꢁ00
N/A
2315003
NA
*TYQꢁ6D1ꢁLL38ꢁ00
N/A
28
*5055548
N/A
2305972
2201371
2201391
2201369
*5055548
N/A
2305972
2201371
2201391
2201369
29
30
31
32
LEADꢀWIREꢀASSEMBLY
SPARKꢀMODULE
PCBꢀASSEMBLY
*ꢀVERSIONꢀNOTꢀSHOWNꢀINꢀEXPLODEDꢀVIEW
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
19
Warranty
LIMITED WARRANTY:
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any
defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either
provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers
as directed by GHP Group, Inc., within one (1) year of retail purchase. (Shipping costs, labour costs, etc. are the responsibility of the purchaser.)
DUTIES OF THE OWNER:
This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse
the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled
check or payment record must be kept to verify purchase date and establish warranty period. Original carton should be kept in case of warranty
return of unit.
WHAT IS NOT COVERED:
1.
2.
3.
4.
5.
6.
Damage resulting from use of improper fuel.
Damage caused by misuse or use contrary to the owners manual and safety guidelines.
Damage caused by a lack of normal maintenance.
Fuses
Use of non-standard parts or accessories.
Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.
This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of
routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of
maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM
GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.
THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE
REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL
GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not
allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.
CLAIMS HANDLED AS FOLLOWS:
1. Contact your retailer and explain the problem.
2. If the retailer is unable to resolve the problem, contact ourCustomer Service Dept. detailing the heater model, the problem, and proof
of date of purchase.
3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY
NAME: ______________________________________ PHONE: (
) __________________ EMAIL: ____________________________
ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________
MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________
DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________
CITY & STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________
Please Take a Minute To Give Us Your Answers To The Following Questions.
All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.
Who primarily decided this purchase?
Male
Female
18-24
25-39
40-59
60 and over
Purpose of Purchase? _______________________________________________________________________________________________
Do you own any other portable heaters? Yes No If yes, type____________________________brand_____________________
How do you intend to use your new heater?
How did you become aware of this heater?
Construction Site
In-Store Display
Farm
Newspaper Ad
Warehouse/Commercial
Garage/Outbuilding Other
Friend/Relative
Magazine Ad
TV Commercial
What made you select this heater?
Do you: own rent Would you recommend this heater to a friend?
Store Salesperson Other ___________________________
Style
Size/Portability
Price
Package
No
Brand
Other ___________________
Yes
Please give us your comments:________________________________________________________________________________________
THANK YOU FOR COMPLETING THIS FORM!
Information will be held confidential.
20
WARRANTY REGISTRATION
IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14)
days of date of purchase. You can also register your warranty on the internet at
for your records.
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
Tel: (877) 447-4768
SAVE THIS CARD!
Place
Postage
Stamp
Here
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
|