CRU DATA EXPRESS DX175 User Manual

Data Express® DX175  
User Manual  
Features  
Short frame length is ideal for fitting in smaller computers  
Toolless entry into the drive carrier  
Temperature Control Cooling System auto-adjusts fan speed  
depending on need  
Push-button carrier ejection mechanism  
Keylock secures the carrier from accidental ejection  
Rated for up to 50,000 carrier insertions  
Data Express DX175 User Manual  
3
2 Frame Installation  
a. Slide the DX175 receiving frame into an open 5.25-inch drive bay on your computer.  
b. Secure the frame to the chassis with the mounting screws provided.  
c. Attach a SAS or SATA data cable to the SAS/SATA data connector on the rear of the frame and attach  
the other end to the appropriate SAS or SATA host inside your computer.  
d. Attach a SATA power connector from your computer to the rear of the frame.  
3 Drive Installation  
a. Unlock the carrier if it is locked into the frame. Insert a Data Express Key into the lock and turn it 90  
degrees counterclockwise.  
b. Push in on the ejection button of the carrier to pop it out.  
c. Press in on the button securing the cover to the rear of the carrier and lift the cover upwards to remove  
it.  
d. Mount a 3.5-inch or 2.5-inch drive inside of the carrier.  
e. With one hand on top of the drive, turn the carrier over. Then secure the drive to the carrier using the  
screws provided.  
f. Reattach the carrier cover. Insert the front of the carrier into the front of the cover while simultaneously  
lowering the cover over the top of the carrier.  
4 Operating Your DX175  
4.1 Powering on the DX175  
a. Insert the DX175 carrier into the frame. Push it in until the carrier clicks.  
b. You may optionally secure the carrier to the frame. Insert the provided Data Express Key into the  
keylock and turn it 90 degrees clockwise.  
c. To power the DX175 on, press and hold the power button until the Drive Ready LED begins to  
flash.  
If a carrier containing a drive is already installed into the receiving frame before a system  
power up, you do not have to press and hold the switch to power on the drive. The DX175  
will turn on automatically when the system is powered on.  
4
Data Express DX175 User Manual  
Your DX175 removable drive enclosure is now ready to use! If the drive inside is already formatted, it  
can be used right away. If the drive is brand new or its format is not compatible with your computer, the  
drive will need to be formatted before being used.  
Formatting a drive will erase all data on the drive, so be sure to back up your data before  
beginning this operation.  
4.2 Ejecting A Carrier  
a. Turn off the computer or properly dismount the drive from the system. To dismount the drive,  
ensure there are no file transfers in progress and the white Drive Activity LED is off before turning  
the DX175 off.  
b. Unlock the carrier if it is locked into the frame. Insert a Data Express Key into the lock and turn it  
90 degrees counterclockwise.  
c. Press in on the eject button to eject the carrier.  
5 Other Configuration Options  
5.1 Error Reporting Disable Switch  
This switch (see Figure 1) is located right below the power switch on the front of the DX175 and  
allows the user to disable the red error LED on the Drive Ready/Error LED. Insert a paper clip or similar  
object into the hole to activate the switch and disable error reporting.  
5.2 Drive Activity LED Polling  
Some SATA PC systems and host controllers provide support for the Drive Activity LED feature. The  
Drive Activity LED can be enabled via host connection (cable not included) to the “Remote LED” pin  
located on the rear of the DX175 frame. Refer to your SATA PC system or host controller manufac-  
turer’s documentation for further information.  
5.3 Drive Auto Spinup  
To disable the drive from spinning up automatically when the host computer is turned on, place a  
jumper on the “Auto Start” pins located on the rear of the DX175 frame.  
Data Express DX175 User Manual  
5
5.4 Fan Speed  
Adjust the fan speed by adjusting the “Fan” jumper located on the rear of the DX175 frame.  
Fan Jumper Settings  
High - Fan is set to high speed  
Low - Fan is set to low speed  
Auto - Fan speed is automatically adjusted depending on the internal temperature of the DX175.  
Product Models  
Data Express DX175  
Interface Types &  
Speeds  
SATA: up to 6 Gbps  
SAS: up to 6 Gbps  
Supported Drive Types  
2.5-inch and 3.5-inch SATA hard drives and SSDs  
2.5-inch and 3.5-inch SAS hard drives and SSDs  
Data Connectors  
Insertion Rating  
Torque  
One (1) SATA connector  
Up to 50,000 carrier insertions  
2.5-inch drives, M3 screws: 4 inch-pounds max.  
3.5-inch drives, #6-32 screws: 6 inch-pounds max.  
Supported Operating  
Systems  
Windows 10, 8, and 7  
Windows Server 2016, 2012 and 2008 product families  
OS X/macOS 10.11 “El Capitan” or newer  
Linux distributions that support the connection type used  
Compliance  
EMI Standard: FCC Part 15 Class B  
EMC Standard: EN55024, EN55032  
CE, RoHS, RCM  
Product Weight  
1.2 pounds (0.54 kg)  
Product Dimensions  
With Fan: 5.75in W x 7.37in L x 1.66in H (147mm W x 187mm L x 42mm H)  
Without Fan: 5.75in W x 6.77in L x 1.66in H (147mm W x 172mm L x 42mm H)  
Technical Support  
Your investment in CRU products is backed up by our free technical support for the lifetime  
of the product. Contact us through our website, cru-inc.com/support or call us at 1-800-  
260-9800 or +1-360-816-1800.  
©2018 CRU Acquisition Group LLC, ALL RIGHTS RESERVED. CRU® and Data Express® are trademarks of CRU Acquisition Group, LLC and are  
protected by trademark law.  
Product Warranty  
CRU warrants this product to be free of significant defects in material and workmanship for a period of five years from the original date of purchase.  
CRU’s warranty is nontransferable and is limited to the original purchaser.  
Limitation of Liability  
The warranties set forth in this agreement replace all other warranties. CRU expressly disclaims all other warranties, including but not limited to, the  
implied warranties of merchantability and fitness for a particular purpose and non-infringement of third-party rights with respect to the documenta-  
tion and hardware. No CRU dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty. In no event will  
CRU or its suppliers be liable for any costs of procurement of substitute products or services, lost profits, loss of information or data, computer mal-  
function, or any other special, indirect, consequential, or incidental damages arising in any way out of the sale of, use of, or inability to use any CRU  
product or service, even if CRU has been advised of the possibility of such damages. In no case shall CRU’s liability exceed the actual money paid  
for the products at issue. CRU reserves the right to make modifications and additions to this product without notice or taking on additional liability.  
FCC Compliance Statement: “This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1)  
This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause  
undesired operation.”  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits  
are designed to provide reasonable protection against harmful interference when the equipment is operated in a home or commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,  
may cause harmful interference to radio communications.  
In the event that you experience Radio Frequency Interference, you should take the following steps to resolve the problem:  
1)  
2)  
3)  
4)  
Ensure that the case of your attached drive is grounded.  
Use a data cable with RFI reducing ferrites on each end.  
Use a power supply with an RFI reducing ferrite approximately 5 inches from the DC plug.  
Reorient or relocate the receiving antenna.  
Part Number: A9-175-0000 Rev. 2.1  
1000 SE Tech Center Dr. Suite 160, Vancouver WA, 98683  

York Champion D2eb User Manual
Trion Air Boss Dc 96 User Manual
Trane Air Conditioner Unitrane Fan Coil Force Flo Air Conditioners User Manual
Sears Air Conditioner Lt143cnr User Manual
Ricoh Pro 1357ex User Manual
KENWOOD K25CB12 User Manual
HP 2620 User Manual
Hampton Bay Southwind 52 User Manual
CRAFTSMAN 917.270912 User Manual
ACER B122D User Manual