3Com® Switch 8800 Family
Installation Guide
Switch 8807
Switch 8810
Switch 8814
www.3Com.com
Part No. 10015593, Rev. AB
Published: June, 2007
CONTENTS
ABOUT THIS GUIDE
This guide describes the 3Com® Switch 8800 and how to install hardware,
configure and boot software, and maintain software and hardware. This guide
also provides troubleshooting and support information for your switch.
This guide is intended for Qualified Service personnel who are responsible for
configuring, using, and managing the switches. It assumes a working knowledge
of local area network (LAN) operations and familiarity with communication
protocols that are used to interconnect LANs.
Always download the Release Notes for your product from the 3Com World Wide
Web site and check for the latest updates to software and product
documentation:
n
http://www.3com.com
Conventions
Table 1 Notice Icons
Icon
Notice Type
Description
Information that describes important features or
instructions.
nInformation note
Information that alerts you to potential loss of data
or potential damage to an application, system, or
device.
cCaution
wWarning
Information that alerts you to potential personal
injury.
Table 2 Text Conventions
Convention
Description
Screen displays
This typeface represents information as it appears on the
screen.
Keyboard key names
If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+), for example:
Press Ctrl+Alt+Del
The words “enter” and “type” When you see the word “enter” in this guide, you must type
something, and then press Return or Enter. Do not press
Return or Enter when an instruction simply says “type.”
6
ABOUT THIS GUIDE
Table 2 Text Conventions
Convention
Description
Words in italics
Italics are used to:
Emphasize a point.
Denote a new term at the place where it is defined in the
text.
Identify menu names, menu commands, and software
button names.
Examples:
From the Help menu, select Contents.
Click OK.
Words in bold
Boldface type is used to highlight command names. For
example, “Use the display user-interfacecommand
to...”
Related
Documentation
The following manuals offer additional information necessary for managing your
Switch 8800:
■
Switch 8800 Command Reference Guide — Provides detailed descriptions of
command line interface (CLI) commands, that you require to manage your
Switch 8800.
■
■
Switch 8800 Configuration Guide— Describes how to configure your Switch
8800 using the supported protocols and CLI commands.
Switch 8800 Release Notes — Contains the latest information about your
product. If information in this guide differs from information in the release
notes, use the information in the Release Notes.
These documents are available in Adobe Acrobat Reader Portable Document
Format (PDF) on the 3Com World Wide Web site:
http://www.3com.com/
About this Document
3Com supports only the commands that are described in this document set. You
may encounter commands in the device’s command line interface (CLI) that are
not described in this guide. Any command that you see in the CLI but is not
described in this guide is not supported in this version of the software.
Unsupported commands may result in a loss of data and you enter them at your
own risk.
c
PRODUCT OVERVIEW
1
Preface
The 3Com Switch 8800 Family of Routing Switches (referred to as the Switch 8800
Family) are intelligent, multi-layer modular LAN switches and are ideal for
enterprise environments where non-stop availability of critical applications and the
highest performance, security, and granular control are required. The Switch 8800
Family delivers high density Gigabit and 10 Gigabit switching in an integrated
chassis platform. Built-in support for IPv6, MPLS, Power over Ethernet (PoE), and
1.44 Tbps backplane capacity ensures unprecedented investment protection.
Resilient Layer-3 routing, hot-swap modules, and redundant power, along with
sub one-second fabric fail over on the Switch 8800, ensure (24 x 7) availability to
support the most demanding enterprise core and campus environments.
Advanced Quality of Service features such as bandwidth management and packet
classification optimize quality for real-time voice and video applications. Intrusion
prevention security capabilities such as IEEE 802.1X Network Login and Access
Control Lists ensure that only authorized users can access network resources.
The Switch 8800 is focused on delivering functionality towards the higher end of
the large Enterprise, with a 4-port 10 Gigabit Module, high density 48-port
Gigabit Modules, as well as a group of Advanced Modules with support for larger
routing tables and/or MPLS. Power over Ethernet (PoE) is built into all Switch
8800s.
Application modules for the Switch 8800 provide the flexibility to add a firewall,
IPsec encryption, network monitoring with NetFlow, and Layer 2 VPN networking
using Virtual Private LAN Service (VPLS) by simply adding a module to the chassis.
8
CHAPTER 1: PRODUCT OVERVIEW
Currently, the Switch 8800 Family include the following models:
■
Switch 8807: This model provides up to 600 Gbps switching capacity. It
supports (for example) up to 240 GE ports and 20 x 10GE ports.
Figure 1 3Com Switch 8807 (7-Slot Chassis)
■
Switch 8810: This model provides up to 960 Gbps switching capacity. It
supports (for example) up to 192 GE ports and 32 x 10GE ports.
Figure 2 3Com Switch 8810 (10-Slot Chassis)
Preface
9
■
Switch 8814: This model provides up to 1.44 Tbps switching capacity. It
supports (for example) up to 576 GE ports and 48 x 10GE ports.
Figure 3 3Com Switch 8814 (14-Slot Chassis)
10
CHAPTER 1: PRODUCT OVERVIEW
General Architecture
The Switch 8800 Family use integrated chassis, which can be subdivided into
power area, board area, backplane and fan area.
Chassis and Slots Switch 8807
Figure 4 Switch 8807 slots
Fabric
Fabric
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
PoE
Entry
AC PSU
AC PSU
■
The Switch 8807 chassis provides seven slots in its board area: The top two
accommodate fabrics, which can operate in 1+1 redundancy mode; the
remaining five accommodate I/O or application modules, which you can select
from various available models. All modules in this area are hot-swappable.
■
■
At the bottom of the chassis is the power area that can accommodate one PoE
entry module and two PSUs. The two PSUs are online-swappable; they can
operate in 1+1 redundancy mode. The switch supports AC power inputs.
On the right of the chassis is the fan area that contains one vertical
hot-swappable fan tray. The fan tray draws and exhausts air from left to right.
General Architecture
11
Switch 8810
Figure 5 Switch 8810 slots
I/O Module
I/O Module
I/O Module
I/O Module
Fabric
Fabric
I/O Module
I/O Module
I/O Module
I/O Module
PoE
Entry
AC PSU
AC PSU
■
The Switch 8810 chassis provides ten slots in its board area: The middle two
accommodate fabric modules, which can operate in 1+1 redundancy mode;
the remaining eight accommodate I/O or application modules, which you can
select from various available models. All modules in this area are
hot-swappable.
■
■
At the bottom of the chassis is the power area that can accommodate one PoE
entry module and two PSUs. The two PSUs are online-swappable; they can
operate in 1+1 redundancy mode. The switch supports AC power inputs.
On the right of the chassis is the fan area that contains one vertical
hot-swappable fan tray. The fan tray draws and exhausts air from left to right.
12
CHAPTER 1: PRODUCT OVERVIEW
Switch 8814
Figure 6 Switch 8814 slots
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
Fabric
Fabric
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
PoE
entry
AC PSU
AC PSU
■
The Switch 8814 chassis provides 14 slots in its board area: The middle two
accommodate fabric modules, which can operate in 1+1 redundancy mode;
the remaining 12 accommodate I/O or application modules, which you can
select from various available models. All modules in this area are
hot-swappable.
■
■
At the bottom of the chassis is the power area that can accommodate one PoE
entry module and two PSUs. The two PSUs are online-swappable. The switch
supports AC power inputs.
On the right of the chassis is the fan area that contains two vertical
hot-swappable fan trays. The fan trays draw and exhaust air from left to right.
Backplane The backplane of the Switch 8800 Family allows high-speed data exchange
between fabrics and I/O modules, as well as the exchange of various management
and control signals in the system.
Functions
The following are the main functions of the backplane:
■
■
■
■
Providing communication channels for signal exchange between boards
Supporting board hot-swapping
Supporting auto-discovering boards in slots
Connecting PSUs, distributing power and providing monitor channels to
various components (PSUs, fabrics and I/O modules) in the chassis.
Structure
Switch 8807
■
General Architecture
13
The Switch 8807 uses a passive backplane, which provides five I/O module
interfaces, two fabric interfaces, one fan interface, and three -48V power
interfaces (two for PSUs and one for PoE entry module).
■
Switch 8810
The Switch 8810 uses a passive backplane, which provides eight I/O module
interfaces, two fabric interfaces, one fan interface, and three -48V power
interfaces (two for PSUs and one for PoE entry module).
■
Switch 8814
The Switch 8814 uses a passive backplane, which provides 12 I/O module
interfaces, two fabric interfaces, two fan interfaces, and three -48V power
interfaces (two for PSUs and one for PoE entry module).
AC Power System
■
■
■
The Switch 8800 Family supports AC power inputs.
n
The Switch 8800 Family supports 1+1 power supply redundancy.
The PSUs of the Switch 8800 Family are online-swappable.
The Switch 8800 Family supports AC power inputs. The power frame is at the
bottom of the chassis, with a height of 3U. In the same slot, you can insert an AC
PSU. The power frame is in different compartment from the functional board
frame and connected to the latter with cables, which are routed along the back of
the chassis. The power supply is cooled by built-in fans of the PSUs, which draw air
into the chassis from the front and exhaust air out of the chassis from the back.
Table 1 Specifications for AC PSUs
Specifications
Item
Switch 8807
Switch 8810
Switch 8814
Rated voltage
range
100 to 240 VAC,
50/60 Hz
100 to 120 VAC, 60 Hz 100 to 120 VAC, 60 Hz
200 to 240 VAC, 50 Hz 200 to 240 VAC, 50 Hz
Max voltage range 90 to 264 VAC, 50/60 90 to 264 VAC, 50/60 90 to 264 VAC, 50/60
Hz
Hz
Hz
Max input current 15 A
Max output power 1200 W
15 A
15 A
1200 W (90 to 160 V) 1200 W (90 to 160 V)
2000 W (160 to 264 V) 2000 W (160 to 264 V)
PoE Power Supply The Switch 8800 Family supports Power over Ethernet (PoE). With this feature, a
Switch 8800 Family switch equipped with an external PoE power supply and
PoE-capable modules can deliver 48 VDC to its remotely powered devices (PDs,
such as IP phones, WLAN APs and network cameras) through twisted pairs.
■
The Switch 8800 Family can supply power to remote PDs through the Ethernet
electrical ports on the I/O modules. Each I/O module can simultaneously supply
power to up to 48 PDs with the maximum distance of 100 m (328.1 feet).
■
Each Ethernet port can deliver up to 15.4 W to its PD.
14
CHAPTER 1: PRODUCT OVERVIEW
■
A Switch 8800 supports up to 4500 W (220 V)/2250 W (110 V) power to its
PDs. It determines whether to deliver power to a newly detected PD depending
on the power it currently supplied.
PoE entry area
The PoE-supported Switch 8807/Switch 8810/Switch 8814 chassis has a PoE entry
area between the two power supply units. You can insert a PoE 3C17510 Switch
8800 PoE Entry Module into this area, and connect this module to a 3C17509
Switch 8800 External PoE Power Rack so as to import the output power of the
External Power Rack unit.
Figure 7 PoE entry module
External PoE Power Rack (3C17509)
The Switch 8800 External Power Rack is available for the Switch 8807, Switch
8810, and Switch 8814. The External Power Rack has three AC inputs and one DC
Figure 8 Front panel of the 3C17509 Switch 8800 External Power Rack PoE power supply
The external PoE power system supports 2+1 redundancy and online-swapping of
PSUs.
n
To implement the PoE function on the Switch 8800 Family, PoE-capable interface
module is required. There are two modules are PoE-capable:
■
■
3C17528 Switch 8800 48-port 10/100/1000BASE-T
3C17532 Switch 8800 48-port 10/100/1000BASE-T Access
Both of these I/O Modules are PoE-capable, and will function with the addition of
a 3C17529 PoE Option (PoE DIMM Module).
General Architecture
15
PoE power system.
Table 2 Typical equipment configurations and specifications of external PoE power system
Item
Description
Physical dimensions (H x W x D)
System controller
177 x 486 x 320.5 mm (7.0 x 19.1 x 12.6 in.)
One
Rectifier
Two NP2500UAC (required) + one redundant
NP2500UAC (optional)
AC accessory
Three AC inputs and switches
Three-phase AC voltage detection circuit
Input voltage range: 90 to 290 VAC; rated voltage
and current: 250 VAC, 20 A
DC accessory
A single DC output, with max output current of
93 A
Max power consumption
4500 W
The external PoE power system has monitor function. It provides one system
monitoring module, one RS232 and two RS485 monitoring interfaces. The system
monitoring module reports the running information of the PSUs in the system to a
fabric through RS232 or RS485 interface and indicates alarm status by the alarm
LED (ALM). You can connect cables to the interfaces from the front as well as the
rear of the frame.
The external PoE power system for the Switch 8800 Family only supports the
RS485 monitoring interface.
n
Table 3 LEDs of external PoE power system
Normal Abnormal
LED
Label Color state
state
Abnormal reason
Input power LED
AC
Green ON
OFF
Loss of AC input power, or blown
fuse
Output power LED DC
Fault LED
Green ON
OFF
ON
No DC output from PSU
Fault Red
OFF
Irreversible fault occurred in PSU
Running status LED RUN
Green ON
OFF
PSU shutdown or PSU running
trouble
Alarm LED
ALM Red
OFF
ON
Loss of AC input power,
under-voltage or over-voltage
input, under-voltage or
over-voltage output, or PSU fault
MBUS Introduction
The MBUS is a service-independent maintenance and test bus. No service traffic
goes through the MBUS. The shutdown and reset of the MBUS does not affect the
services on the switch, and faults that have occurred on modules do not affect the
MBUS.
Through the MBUS, the system instructs the MBUS modules on individual cards to
power on/off the cards one by one in turn, thus prevent power surging. The MBUS
module software must support online upgrade.
16
CHAPTER 1: PRODUCT OVERVIEW
Role and function
The MBUS system is powered by 5 V from the MBUS on the fabric. The 5 V power
on the two fabrics are redundant to each other.
Each MBUS module is attached to the MBUS, which contains two control lines:
MBUS0 and MBUS1.
Each card has an independent MBUS module, those on the fabrics are primary
MBUS modules, and those on application modules are secondary MBUS modules.
When the fabrics operate in redundancy mode, the MBUS module on the active
fabric is the active module, and the one on the standby fabric is the standby
module.
The MBUS uses a controller area network (CAN) bus as its control bus, that uses
the 1:1 hot backup and transfers control information at 1 Mbps.
Fan Tray
■
■
■
The Switch 8807 uses one 25 W fan tray, which contains four 120 x 120 x 25.4
mm (4.7 x 4.7 x 1.0 in.) axial fan units. The fans can be governed in two
modes: fabric-controlled or temperature-controlled. They operate at -48 VDC
supplied from the backplane.
The Switch 8810 uses one 35 W fan tray, which contains six 120 x 120 x 25.4
mm (4.7 x 4.7 x 1.0 in.) axial fan units. The fans can be governed in two
modes: fabric-controlled or temperature-controlled. They operate at -48 VDC
supplied from the backplane.
The Switch 8814 uses two 25 W fan trays, each of which contains four 120 x
120 x 25.4 mm (4.7 x 4.7 x 1.0 in.) axial fan units (and totally eight for the two
fan trays). The fans can be governed in two modes: fabric-controlled or
temperature-controlled. They operate at -48 VDC supplied from the backplane.
Figure 9 Fan tray panel of the Switch 8800 Family
Fabric Modules
17
Table 4 LEDs on fan tray panel
LED
Color Status Status
RUN
Green OFF
ON
The fan tray is faulty.
The fan tray is operating normally.
The fan tray is operating normally.
The fan tray is faulty.
ALM
Red
OFF
ON
Fabric Modules
The Switch Fabric serves as the core of the Switch 8800 Family.The following fabric
models are available to the Switch 8800 Family:
■
■
3C17508 - 3Com Switch 8800 360 Gbps Fabric
3C17539 - 3Com Switch 8800 720 Gbps Fabric
These fabric modules provide:
■
■
Route calculating and forwarding table maintenance.
Integrating Crossbar switching fabric to accomplish service exchange between
different boards.
■
System configuration and monitoring functions, which allows the system to
monitor other boards and upgrade/reset service board software.
360 Gbps Switch Fabric Technical specifications
Table 5 360 Gbps Switch Fabric specifications
Item
Specifications
MPC755
CPU
Boot ROM
SDRAM
512 KB
512 MB (expandable to 1 GB)
Physical dimensions (W x D) 366.7 x 340 mm (14.4 x 13.4 in.)
Port
One Console port, for local configuration management
One AUX port, for remote dialup configuration management
One 10Base-T/100Base-TX port, for software upgrade and
network management
One RS232/485 port, for connecting external PoE power frame
to provide the PoE function
One hot-swap-supported CF port
Max power consumption
60 W
Panel
On its panel, the 360 Gbps Switch Fabric provides a CF port, CF LED (CFS),
10Base-T/100Base-TX port, RS232/485 port, Console port, AUX port, RESET
button, I/O module status LEDs, and 360 Gbps Switch Fabric status LEDs (SFS,
18
CHAPTER 1: PRODUCT OVERVIEW
Figure 10 360 Gbps Switch Fabric panel
Compact Flash (CF slot)
The 360 Gbps Switch Fabric module provides a CF slot to accommodate a
standard CF card, where you can save logging information, host version
information, alarming and other diagnostic information and conveniently upgrade
software online. The fabric ships with a CF memory card.
Management Ports
The Management 10Base-T/100Base-TX port uses an RJ-45 connector. It can
connect a background terminal for system program loading and debugging, or
connect a network management station for remote system management.
Table 6 Management 10Base-T/100Base-TX port specifications
Item
Description
Connector
Number of ports
Rate
RJ-45
One
10 Mbps, half duplex/full duplex
100 Mbps, half duplex/full duplex
Max. transmission segment over the selected 100 m (328 ft.) over the category-5 twisted
medium
pair cable (crossover cable is required).
Service
System program upgrade and network
management
The following table describes the status LEDs for the management
10Base-T/100Base-TX port.
Table 7 Status LEDs for the management 10Base-T/100Base-TX port
LED
Status
OFF
LINK
No link is present.
ON
A link is present.
ACT
OFF
No packets are transmitted/received on the port.
Packets are being transmitted/received on the port.
Blinking
■
RS232/485 port
The RS232/485 port uses RJ-45 connector, for connecting external PoE power
frame when supported and monitoring its status.
Table 8 RS232/485 port specifications
Item
Description
Connector
Number of ports
RJ-45
One RS 232 port and one RS485 port
Fabric Modules
19
Table 8 RS232/485 port specifications
Item
Description
Service
The port for monitoring and communication with the external subsystem,
such as external PoE power supply module
■
Console port
The Console port uses an RJ-45 connector. It can be connected to a background
terminal for system debugging, maintenance, management, and host software
loading.
Table 9 Console port specifications
Item
Description
Connector
Standard
Baud rate
RJ-45
Asynchronous EIA/TIA-232
9600 bps (default)
15 m (49 ft.)
Transmission
segment
Service
Connects a serial port of a local PC and runs terminal emulation on the
PC.
You can choose your own baud rate for the Console port.
n
■
AUX port
The AUX port uses an RJ-45 connector. The port can serve as a backup port for the
Console port to connect a background terminal, or directly connect a modem
device, for remote system debugging, configuration, maintenance and
management.
Table 10 AUX port specifications
Item
Description
Connector RJ-45
Standard
Service
Asynchronous EIA/TIA-232
Connects a serial port of a PC (through a Modem pair for a remote PC) and runs
terminal emulation on the PC.
RESET button
You can press the RESET button on the panel to reset the 360 Gbps Switch Fabric
module.
Status LEDs
■
CF status LED
You can learn the operating status of the CF card by reading the CF status LED on
the panel.
20
CHAPTER 1: PRODUCT OVERVIEW
Table 11 CF status LED
LED
CFS
Status
ON
The CF card is in position and is idle. You cannot remove the card.
Blinking
The CF card is in position and reading/writing data. You cannot remove
the card.
OFF
The CF card is out of position or offline (you can force the in-position CF
card to go offline using the appropriate background command). You can
remove/insert the card.
■
Status LEDs for I/O module
The 360 Gbps Switch Fabric module has 12 pairs of LEDs to indicate the operating
status of 12 I/O module.
Table 12 Status LEDs for I/O module
LED
Status
ON
RUN
The module is faulty.
OFF
The module is faulty or out of position.
The module is running normally.
Blinking (1s)
Fast blinking (125 ms) The module is booting or not registered successfully.
ALM
ON
The module has alarms.
OFF
The module has no alarms or is out of position.
0~5,
Indicate slots 0 through 5 and slots 8 through 13
8~13
■
Status LEDs for the 360 Gbps Switch Fabric module
You can learn the operating status of 360 Gbps Switch Fabric module by reading
the SFS, ACT, ALM and RUN LEDs on it. The following table gives a summary of
the four LEDs.
Table 13 Status LEDs for the 360 Gbps Switch Fabric module
360 Gbps Switch
Fabric LED
Status
ON
SFS
The switching fabric unit is active.
OFF
The switching fabric unit is standby.
RUN
Green
OFF
The 360 Gbps Switch Fabric module is faulty.
The 360 Gbps Switch Fabric module is faulty.
Green blinking The 360 Gbps Switch Fabric module runs normally.
ALM
ACT
Red
The 360 Gbps Switch Fabric module has alarms.
The 360 Gbps Switch Fabric module has no alarms.
The 360 Gbps Switch Fabric module is active.
The 360 Gbps Switch Fabric module is standby.
OFF
Green
OFF
Fabric Modules
21
720 Gbps Switch Fabric Technical specifications
Table 14 720 Gbps Switch Fabric specifications
Item
Specifications
MPC755
CPU
Boot ROM
SDRAM
512 KB
512 MB (expandable to 1 GB)
Physical dimensions (W x D) 366.7 x 340 mm (14.4 x 13.4 in.)
Port
One Console port, for local configuration management
One AUX port, for remote dialup configuration management
One 10Base-T/100Base-TX port, for software upgrade and
network management
One RS232/485 port, for connecting external PoE power frame
to provide the PoE function
One hot-swap-supported CF port
Max power consumption
110 W
Panel
On its panel, the 720 Gbps Switch Fabric provides a CF slot, CF LED (CFS),
10Base-T/100Base-TX port, RS232/485 port, Console port, AUX port, RESET
button, I/O module status LEDs, and 360 Gbps Switch Fabric status LEDs (SFS,
card.
Figure 11 720 Gbps Switch Fabric panel
Compact Flash (CF slot)
The 720 Gbps Switch Fabric module provides a CF port to accommodate a
standard CF card, where you can save logging information, host version
information, alarming and other diagnostic information and conveniently upgrade
software online.
Management Ports
The Management 10Base-T/100Base-TX port uses an RJ-45 connector. It can
connect a background terminal for system program loading and debugging, or
connect a network management station for remote system management.
Table 15 Management 10Base-T/100Base-TX port specifications
Item
Description
Connector
Number of ports
Rate
RJ-45
One
10 Mbps, half duplex/full duplex
100 Mbps, half duplex/full duplex
22
CHAPTER 1: PRODUCT OVERVIEW
Table 15 Management 10Base-T/100Base-TX port specifications
Item Description
Max. transmission segment over the selected 100 m (328 ft.) over the category-5 twisted
medium
pair cable (crossover cable is required).
Service
System program upgrade and network
management
The following table describes the status LEDs for the management
10Base-T/100Base-TX port.
Table 16 Status LEDs for the management 10Base-T/100Base-TX port
LED
Status
OFF
LINK
No link is present.
ON
A link is present.
ACT
OFF
No packets are transmitted/received on the port.
Packets are being transmitted/received on the port.
Blinking
■
RS232/485 port
The RS232/485 port uses RJ-45 connector, for connecting external PoE power
frame when supported and monitoring its status.
Table 17 RS232/485 port specifications
Item
Description
Connector
Number of ports
Service
RJ-45
One RS 232 port and one RS485 port
The port for monitoring and communication with the external subsystem,
such as external PoE power supply module
■
Console port
The Console port uses an RJ-45 connector. It can be connected to a background
terminal for system debugging, maintenance, management, and host software
loading.
Table 18 Console port specifications
Item
Description
Connector
Standard
Baud rate
RJ-45
Asynchronous EIA/TIA-232
9600 bps (default)
15 m (49 ft.)
Transmission
segment
Service
Connects a serial port of a local PC and runs terminal emulation on the
PC.
You can choose your own baud rate for the Console port.
AUX port
n
■
Fabric Modules
23
The AUX port uses an RJ-45 connector. The port can serve as a backup port for the
Console port to connect a background terminal, or directly connect a modem
device, for remote system debugging, configuration, maintenance and
management.
Table 19 AUX port specifications
Item
Description
Connector RJ-45
Standard
Service
Asynchronous EIA/TIA-232
Connects a serial port of a PC (through a Modem pair for a remote PC) and runs
terminal emulation on the PC.
RESET button
You can press the RESET button on the panel to reset the 720 Gbps Switch Fabric
module.
Status LEDs
■
CF status LED
You can learn the operating status of the CF card by reading the CF status LED on
the panel.
Table 20 CF status LED
LED
Status
ON
CFS
The CF card is in position and is idle. You cannot remove the card.
Blinking
The CF card is in position and reading/writing data. You cannot remove
the card.
OFF
The CF card is out of position or offline (you can force the in-position CF
card to go offline using the appropriate background command). You can
remove/insert the card.
■
Status LEDs for I/O module
The 720 Gbps Switch Fabric module has 12 pairs of LEDs to indicate the operating
status of 12 I/O module.
Table 21 Status LEDs for I/O module
LED
Status
ON
RUN
The module is faulty.
OFF
The module is faulty or out of position.
The module is running normally.
Blinking (1s)
Fast blinking (125 ms) The module is booting or not registered successfully.
ALM
ON
The module has alarms.
OFF
The module has no alarms or is out of position.
0~5,
Indicate slots 0 through 5 and slots 8 through 13
8~13
■
Status LEDs for the 720 Gbps Switch Fabric module
24
CHAPTER 1: PRODUCT OVERVIEW
You can learn the operating status of 720 Gbps Switch Fabric module by reading
the SFS, ACT, ALM and RUN LEDs on it. The following table gives a summary of
the four LEDs.
Table 22 Status LEDs for the 720 Gbps Switch Fabric module
360 Gbps Switch
Fabric LED
Status
ON
SFS
The switching fabric unit is active.
OFF
The switching fabric unit is standby.
RUN
Green
OFF
The 720 Gbps Switch Fabric module is faulty.
The 720 Gbps Switch Fabric module is faulty.
Green blinking The 720 Gbps Switch Fabric module runs normally.
ALM
ACT
Red
The 720 Gbps Switch Fabric module has alarms.
The 720 Gbps Switch Fabric module has no alarms.
The 720 Gbps Switch Fabric module is active.
The 720 Gbps Switch Fabric module is standby.
OFF
Green
OFF
RESET button
You can press the RESET button on the panel to reset the 720 Gbps Switch Fabric.
Status LEDs
System Specifications
The following table summarizes the physical specifications of the Switch 8800
Family.
Table 23 Technical specifications of the Switch 8800 Family
Item
Switch 8807
Switch 8810
Switch 8814
Dimensions
(H x W x D)
486 x 436 x 450 mm 619 x 436 x 450 mm 753 x 436 x 450 mm
(19.1 x 17.2 x 17.7
in.)
(24.4 x 17.2 x 17.7
in.)
(29.6 x 17.2 x 17.7 in.)
Weight (full load) 600 kg (143 lb)
80 kg (176 lb)
2000 W
100 kg (220 lb)
2000 W
Max power
1200 W
consumption
Switching
capacity (see
Note 1)
Fab360: 600 Gbps
(see Note 2)
Fab360: 480Gbps
Fab360: 720Gbps
Fab720: 960Gbps
Fab720: 1440Gbps
Number of
VLANs
4 K
Maximum MAC 14 K/per module, total 14 K x number of modules
address table size
See Note 3
Forwarding table 128 K/256 K
entries
Number of fabric
slots
2
2
2
Software Features
25
Table 23 Technical specifications of the Switch 8800 Family
Item
Switch 8807
Switch 8810
Switch 8814
fabric module
type
360 Gbps Fabric
360 Gbps Switch
Fabric
360 Gbps Switch Fabric
720 Gbps Switch Fabric
720 Gbps Switch
Fabric
Number of I/O
module slots
5
8
12
User interface
10/100/1000BASE-TX RJ45
1000BASE-X (SFP)
10BASE-X (XENPAK)
10BASE-X (XFP)
Operating
0 to 40C (32 to 104F)
temperature
Operating
10% to 90%
humidity
(noncondensing)
Storage
-10 to 70C (14 to 158F)
temperature
Storage humidity 10% to 90%
Note 1: The switching capacity in the above table is calculated based on two
load-sharing fabrics.
n
Note 2: The 7-slot has additional backplane traces per slot compared to the
14-slot and the 10- slot chassis. The additional traces enable higher capacity per
slot using the 360G Fabric compared to the 10-slot and 14-slot chassis.
Note 3: See the Switch 8800 Configuration Guide for rules and limitations.
Software Features
The software of the Switch 8800 Family uses fully distributed processing and runs
on 3Com network operating system Comware. The following table summaries the
supported software features.
Table 24 Software features of the Switch 8800 Family
Item
Description
VLAN
IEEE 802.1Q-compliant VLAN
Port-based, protocol-based (8 groups), IP subnet-based
VLAN division
GARP VLAN registration protocol (GVRP)
Super VLAN
Isolate user VLAN
Guest VLAN
Dynamic VLAN
STP
IEEE 802.1d/IEEE 802.1w/IEEE 802.1s-compliant
spanning tree protocol (STP)/rapid STP (RSTP)/multiple
STP (MSTP)
26
CHAPTER 1: PRODUCT OVERVIEW
Table 24 Software features of the Switch 8800 Family
Item
Description
Flow control
IEEE 802.3x flow control (full duplex)
Back pressure flow control (half duplex)
Broadcast/multicast suppression
Multicast
Supported
Internet group management protocol (IGMP) snooping
IGMP
Internet group management protocol (IGMP) v2
Protocol-independent multicast-dense mode (PIM-DM)
Protocol-independent multicast-sparse mode (PIM-SM)
Multicast source discovery protocol (MSDP)
Multiprotocol border gateway protocol (MBGP)
Any-RP
IP routing
Static routing
Routing information protocol (RIP) v1/v2
Open shortest path first (OSPF) v2
Border gateway protocol (BGP)
Intermediate system-to-intermediate system (IS-IS)
Equal cost route forwarding
Routing policy
Policy routing
OSPF/IS-IS/BGP graceful restart (GR)
Aggregation across cards
Link aggregation
DHCP
LACP
DHCP server
DHCP relay
DHCP Option 82
Mirroring
Port-based mirroring
Multiprotocol Label Switching (MPLS) L3 MPLS VPN, inter-domain MPLS VPN, hierarchy of PE
(HoPE), CE dual homing, MCE, multi-role host
VLL: Martini, Kompella, and CCC mode
VPLS
QoS
Traffic classification based on port, MAC address,
VLAN, IP address, IP priority, TCP/UDP port number,
DSCP priority, Type of service (ToS) priority, class of
service (CoS) priority, etc.
Traffic monitoring, with granularity of 8 Kbps
Traffic shaping
Priority mark/remark
Queue scheduling: strict priority (SP), weighted round
Robin (WRR) and SP + WRR <par
8 priority queues for each port
Congestion avoidance algorithms: tail drop (TD) and
weighted random early detection (WRED)
Software Features
27
Table 24 Software features of the Switch 8800 Family
Item
Description
Security
Hierarchical user management and password
protection
Password control
802.1x authentication
Packet filtering
Port-based broadcast frame suppression, speed
calculation in bytes or packets
Protection from attacks by virus packets, such as DOS
attacks
AAA/RADIUS/HWTACACS
SSH 2.0 (security shell)
Firewall
IPsec
Education network accounting
Port VLAN VPN
QinQ
Flexible QinQ
Network Monitoring feature
NetFlow v5/v8/v9
Management and maintenance
Configuration through the command line interface
(CLI)
Configuration through the Console/AUX port
Telnet configuration/maintenance through Ethernet
ports
Modem dialup configuration/maintenance through
AUX port
SNMP management, with the 3Com network
management application, RMON (remote monitoring),
and 1/2/3/9 groups of MIBs.
System logging
Hierarchical alarming
Debugging information output
ping and tracert commands
NQA
Loading and upgrade
Loading and upgrade using the XModem protocol
Loading and upgrade using FTP/TFTP
Loading of BootROM and host software
All specifications are subject to changes without notice. For up-to-date
information, please contact 3Com marketing or technical support personnel.
n
28
CHAPTER 1: PRODUCT OVERVIEW
I/O AND APPLICATION MODULES
2
Overview
The Switch 8800 Family are modular switches that are designed following industry
standards. The following I/O modules are available to the Switch 8800 Family:
Table 25 I/O modules available to the Switch 8800 Family
I/O module
3C17511
3C17512
3C17513
3C17514
3C17516
3C17525
3C17526
3C17527
3C17528
3C17530
3C17531
3C17532
3C17533
3C17534
3C17536
3C17537
3C17538
3C17542
3C17546
3CR1754766
3C17548
User interface
1-port 10GBASE-X (XENPAK)
2-port 10GBASE-X (XFP)
12-port 1000BASE-X (SFP)
24-port 1000BASE-X (SFP)
24-port 10/100/1000BASE-T (RJ-45)
1-port 10GBASE-X (XENPAK) Advanced
4-port 10GBASE-X (XFP)
2-port 10GBASE-X (XFP) Advanced
48-port 10/100/1000 BASE-T (RJ-45)
24-port 1000BASE-X (SFP) Advanced
24-port 10/100/1000BASE-T (RJ-45) Advanced
48-port 10/100/1000BASE-T (RJ-45) Access
24-port 1000BASE-X (SFP) IPv6 Module
24-port 10/100/1000BASE-T (RJ-45) IPv6 Module
4-port 10GBASE-X (XFP) QUAD IPv6
2-port 10GBASE-X (XFP)
48-port 1000BASE-X (SFP) IPv6
Network Monitoring Module
Firewall Module
IPsec Module
Virtual Private LAN Service (VPLS)
3C17511 1-port
10GBASE-X (XENPAK)
Specifications This section provides specifications for the 1-port 10GBASE-X (XENPAK) 3C17511
module.
Table 26 3C17511 module specifications
Item
Specification
CPU
MPC8245
30
CHAPTER 2: I/O AND APPLICATION MODULES
Table 26 3C17511 module specifications
Item
Specification
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm(14.4 x 13.4 in.)
45 W
One
XENPAK/SC
10 Gbps
Rate
Panel and LEDs Figure 12 3C17511 module panel
The 3C17511 module has two port LEDs for the 10GE port on its panel.
Table 27 Port LEDs on the 3C17511 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green ON
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
XENPAK/SC optical/electrical port on the 3C17511 module and their matching
cable types, which you can select as required.
3C17512 2-port
10GBASE-X (XFP)
Module
This section provides specifications for the 2-port 10GBASE-X (XFP) module
(3C17512).
Specifications The 3C17512 modules provide two 10GBASE-X XFP/LC ports.
Table 28 3C17512 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
87 W
Two
XFP
3C17513 12-port 1000BASE-X (SFP) Module
31
Table 28 3C17512 module specifications
Item
Specification
Rate
10 Gbps
Panel and LEDs Figure 13 3C17512 module panel
The 3C17512 module has two LEDs for each optical port on its panel.
Table 29 1000 Mbps optical port LEDs on the 3C17512 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
optical ports on the 3C17512 module and their matching cable types, which you
can select as required.
3C17513 12-port
1000BASE-X (SFP)
Module
This section provides specifications for the 12-port 1000BASE-X (SFP) module
(3C17513)
Specifications The 3C17513 module provides 12 x 1000 Mbps SFP/LC optical ports.
Table 30 3C17513 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
55 W
12
SFP/LC
1.25 Gbps
Rate
Panel and LEDs Figure 14 3C17513 module panel
32
CHAPTER 2: I/O AND APPLICATION MODULES
The 3C17513 module has two LEDs for each port on its panel.
Table 31 Port LEDs on the 3C17513 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
ports on the 3C17513 module and their matching cable types, which you can
select as required.
3C17514 24-port
1000BASE-X (SFP)
Module
This section provides specifications for the 24-port 1000BASE-X (SFP) module
(3C17514).
Specifications The 3C17514 module provides 24 1000BASE-X (SFP) ports.
Table 32 3C17514 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
100 W
24
SFP/LC
1.25 Gbps
Rate
Panel and LEDs Figure 15 3C17514 module panel
The 3C17514 module has two LEDs for each 1000 Mbps optical port on its panel.
Table 33 Port LEDs on the 3C17514 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
3C17516 24-port 10/100/1000BASE-T Module
33
Matching Cable You can select appropriate SFP optical modules for the 1000 Mbps SFP optical
ports on the 3C17514 module according to your needs. For description of SFP
optical modules available to the SFP optical ports and their matching cable types,
3C17516 24-port
10/100/1000BASE-T
Module
This section provides specifications for the 24-port 10/100/1000BASE-T module
(3C17516).
Specifications The 3C17516 module provides 24 10/100/1000BASE-T (RJ45) ports.
Table 34 3C17516 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
110 W
24
RJ-45
Rate
10/100/1000 Mbps
Panel and LEDs Figure 16 3C17516 module panel
The 3C17516 module has one LED for each port on its panel.
Table 35 Port LEDs on the 3C17516 module
LED
Status
ON
Meaning
LINK/ACT
No link is present.
A link is present.
OFF
Blinking Packets are being transmitted/received on the port.
3C17525 1-port
10GBASE-X Advanced
(XENPAK) Module
This section provides specifications for the 1-port 10GBASE-X (XENPAK) Advanced
module (3C17525).
Specifications The 3C17525 module provides one 10GE XENPAK/SC optical/electrical port.
34
CHAPTER 2: I/O AND APPLICATION MODULES
Table 36 3C17511 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm(14.4 x 13.4 in.)
45 W
One
XENPAK/SC
10 Gbps
Rate
Panel and LEDs Figure 17 3C17525 module panel
The 3C17525 module has two port LEDs for the 10GE port on its panel.
Table 37 Port LEDs on the 3C17525 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green ON
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
XENPAK/SC optical/electrical port on the 3C17525 module and their matching
cable types, which you can select as required.
3C17526 4-port
10GBASE-X (XFP)
Module
This section provides specifications for the 4-port 10GBASE-X (XFP) module
(3C17526).
Specifications The 3C17526 module provides four 10GBASE-X (XFP) ports.
Table 38 3C17526 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Number of ports
Max power consumption
366.7 x 340 mm (14.4 x 13.4 in.)
Four
160 W
3C17527 2-port 10GBASE-X (XFP) Advanced Module
35
Table 38 3C17526 module specifications
Item
Specification
XFP
Connector
Rate
10 Gbps
Panel and LEDs Figure 18 3C17526 module panel
The 3C17526 module has two LEDs for each optical port on its panel.
Table 39 1000 Mbps optical port LEDs on the 3C17526 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
Matching Cable For details about XFP optical modules available to the XFP optical ports on the
3C17527 2-port
10GBASE-X (XFP)
Advanced Module
This section provides specifications for the 2-port 10GBASE-X (XFP) Advanced
module (3C17527).
Specifications The 3C17527 module provide two 10GBASE-X XFP/LC ports.
Table 40 3C17527 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
87 W
Two
XFP
Rate
10 Gbps
Panel and LEDs Figure 19 3C17527 module panel
36
CHAPTER 2: I/O AND APPLICATION MODULES
The 3C17527 module has two LEDs for each optical port on its panel.
Table 41 1000 Mbps optical port LEDs on the 3C17527 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
Gbps XFP optical ports on the 3C17527 module and their matching cable types,
which you can select as required.
3C17528 48port
10/100/1000 BASE-T
(RJ-45) Module
This section provides specifications for the 48-port 10/100/1000 BASE-T (RJ-45)
module (3C17528).
Specifications The 3C17528 module provides 48 10/100/1000 BASE-T auto-sensing PoE-capable
RJ-45 ports.
Table 42 3C17528 module specifications
Item
Specification
CPU
MPC8245
BootROM
512 KB
SDRAM
128 MB
Physical dimensions (W x D)
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
48
RJ-45
Rate
10/100/1000 Mbps
Panel and LEDs Figure 20 3C17528 module panel
The 3C17528 module has one LED for each port on its panel.
Table 43 1000 Mbps electrical port LEDs on the 3C17528 module
LED
Status
ON
Meaning
LINK/ACT
A link is present.
No link is present.
OFF
Blinking Packets are being transmitted/received on the port.
3C17530 24-port 1000BASE-X (SFP) Advanced Module
37
3C17530 24-port
1000BASE-X (SFP)
Advanced Module
This section provides specifications for the 24-port 1000BASE-X (SFP) Advanced
module (3C17530).
Specifications The 3C17530 Advanced Module provide 24 1000BASE-X (SFP) ports.
Table 44 3C17530 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
100 W
24
SFP/LC
1.25 Gbps
Rate
Panel and LEDs Figure 21 3C17530 module panel
The 3C17530 module has two LEDs for each 1000 Mbps optical port on its panel.
Table 45 Port LEDs on the 3C17530 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
Matching Cable You can select appropriate SFP optical modules for the 1000 Mbps SFP optical
ports on the 3C17530 module according to your needs. For a description of SFP the
optical modules available for the SFP optical ports and their matching cable types,
3C17531 24-port
10/100/1000BASE-T
Advanced Module
This section provides specifications for the 24-port 10/100/1000BASE-T module
(3C17531).
Specifications The 3C17531 module provides 24 10/100/1000BASE-T (RJ45) ports.
Table 46 3C17531 module specifications
Item
Specification
CPU
MPC8245
38
CHAPTER 2: I/O AND APPLICATION MODULES
Table 46 3C17531 module specifications
Item
Specification
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
110 W
24
RJ-45
Rate
10/100/1000 Mbps
Panel and LEDs Figure 22 3C17531 module panel
The 3C17531 module has one LED for each port on its panel.
Table 47 Port LEDs on the 3C17531 module
LED
Status
ON
Meaning
LINK/ACT
No link is present.
A link is present.
OFF
Blinking Packets are being transmitted/received on the port.
3C17532 48-port
10/100/1000 BASE-T
(RJ-45) Access Module
This section provides specifications for the 48-port 10/100/1000 BASE-T (RJ-45)
Access module (3C17532).
Specifications The 3C17532 module provides 48 10/100/1000 BASE-T auto-sensing PoE-capable
RJ-45 ports.
Table 48 3C17532 module specifications
Item
Specification
CPU
MPC8245
BootROM
512 KB
SDRAM
128 MB
Physical dimensions (W x D)
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
48
RJ-45
Rate
10/100/1000 Mbps
3C17533 24-port 1000BASE-X (SFP) IPv6 Module
39
Panel and LEDs Figure 23 3C17532 module panel
The 3C17532 module has one LED for each port on their panel.
Table 49 1000 Mbps electrical port LEDs on the 3C17532 module
LED
Status
ON
Meaning
LINK/ACT
A link is present.
No link is present.
OFF
Blinking Packets are being transmitted/received on the port.
3C17533 24-port
1000BASE-X (SFP) IPv6
Module
This section provides specifications for the 24-port 1000BASE-X (SFP) IPv6 module
(3C17533).
Specifications The 3C17533 IPv6 module provides 24 1000BASE-X (SFP) ports.
Table 50 3C17533 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
100 W
24
SFP/LC
1.25 Gbps
Rate
Panel and LEDs Figure 24 3C17533 module panel.
The 3C17533 module has two LEDs for each 1000 Mbps optical port on its panel.
Table 51 Port LEDs on the 3C17533 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
40
CHAPTER 2: I/O AND APPLICATION MODULES
Matching Cable You can select appropriate SFP optical modules for the 1000 Mbps SFP optical
ports on the 3C17533 module according to your needs. For a description of SFP the
optical modules available for the SFP optical ports and their matching cable types,
3C17534 24-port
10/100/1000BASE-T
IPv6 Module
This section provides specifications for the 24-port 10/100/1000BASE-T IPv6
module (3C17534).
Specifications The 3C17534 module provides 24 10/100/1000BASE-T (RJ45) ports.
Table 52 3C17534 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
110 W
24
RJ-45
Rate
10/100/1000 Mbps
Panel and LEDs The 3C17534 module has one LED for each port on its panel.
Figure 25 3C17534 module panel
Table 53 Port LEDs on the 3C17534 module
LED
Status
ON
Meaning
LINK/ACT
No link is present.
A link is present.
OFF
Blinking Packets are being transmitted/received on the port.
3C17536 4-port
10GBASE-X (XFP)
QUAD IPv6 Module
This section provides specifications for the 4-port 10GBASE-X (XFP) QUAD IPv6
module (3C17536).
Specifications The 3C17536 module provides four 10GBASE-X (XFP) ports.
Table 54 3C17536 module specifications
Item
Specification
CPU
MPC8245
3C17537 2-port 10GBASE-X (XFP) IPv6 Module
41
Table 54 3C17536 module specifications
Item
Specification
Boot ROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Number of ports
366.7 x 340 mm (14.4 x 13.4 in.)
Four
Max power consumption (with bottom plate) 160 W
Connector
Rate
XFP
10 Gbps
Panel and LEDs Figure 26 3C17536 module panel
The 3C17536 module has two LEDs for each optical port on its panel.
Table 55 1000 Mbps optical port LEDs on the 3C17536 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
Matching Cable For details about XFP optical modules available to the XFP optical ports on the
3C17537 2-port
10GBASE-X (XFP) IPv6
Module
This section provides specifications for the 2-port 10GBASE-X (XFP) IPv6 module
(3C17537).
Specifications The 3C17537 modules provide two 10GBASE-X XFP/LC ports.
Table 56 3C17537 module specifications
Item
Specification
CPU
MPC8245
Boot ROM
512 KB
SDRAM
128 MB/256MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
87 W
Two
XFP
Rate
10 Gbps
42
CHAPTER 2: I/O AND APPLICATION MODULES
Panel and LEDs Figure 27 3C17537 module panel
The 3C17537 module has two LEDs for each optical port on its panel.
Table 57 1000 Mbps optical port LEDs on the 3C17537 module
LED
Status
OFF
Meaning
LINK
No link is present.
Green
OFF
A link is present.
ACT
No packets are transmitted/received on the port.
Orange blinking Packets are being transmitted/received on the port.
optical ports on the 3C17537 module and their matching cable types, which you
can select as required.
3C17538 48-port
1000BASE-X (SFP) IPv6
Module
This section provides specifications for the 48-port 1000BASE-X (SFP) IPv6 module
(3C17538).
Specifications The 3C17538 module provides 48 1000BASE-X (SFP) ports.
Table 58 3C17538 module specifications
Item
Specification
CPU
MPC8245
BootROM
512 KB
SDRAM
128 MB/256 MB
Physical dimensions (W x D)
Max power consumption
Number of ports
Connector
366.7 x 340 mm (14.4 x 13.4 in.)
100 W
48
SFP/LC
1000 Mbps
Rate
Panel and LEDs Figure 28 3C17538 module panel
The 3C17538 module has one LED for each 1000 Mbps optical port on its panel.
Application Modules
43
Table 59 Port LEDs on the 3C17538 module
LED
Status
Meaning
LINK/ACT
Solid on
Solid off
Blinking
A link is present.
No link is present.
The port is transmitting or
receiving data.
Matching Cable You can select appropriate SFP optical modules for the 1000 Mbps SFP/LC optical
for the available SFP optical modules and their matching cable types.
Application Modules
Each Application Module is specially designed for high-speed processing of a
certain network service and shares some features with the I/O Modules.
Currently, the following application module are available to the Switch 8800
Family:
■
■
■
■
3C17542: Network Monitoring Application Module
3C17546: Firewall Application Module
3C1754766: Network Monitoring Application Module
3C17548: VPLS Application Module
3C17542 Network Technical specifications
Monitoring Application
The 3C17542 Network Monitoring Application Module provides no I/O ports.
Module
Table 60 Technical specifications for the 3C17542
Item
Specifications
CPU
MPC755
Boot ROM
512 KB
SDRAM
256 MB
Physical dimensions (W x D)
366.7 x 340 mm (14.4 x 13.4 in.)
Front panel
Figure 29 Front panel of the 3C17542
44
CHAPTER 2: I/O AND APPLICATION MODULES
3C17546 Firewall Technical specifications
Application Module
The 3C17546 Firewall Application Module provides eight Gigabit SFP/LC optical
ports.
Table 61 Technical specifications for the 3C17546
Item
Specifications
CPU
BCM1250
Boot ROM
512 KB
SDRAM
1 Gbps
Physical dimensions (W x D)
366.7 x 340 mm (14.4 x 13.4 in.)
Front panel
Figure 30 Front panel of the 3C17546
The 3C17546 provides eight 1000Base-X ports, one Console port, one AUX port,
three 10/100Base-TX ports and four status LEDs (ATTACK, ACT, ALM and RUN)
from left to right on the front panel.
Table 62 Status LEDs on the 3C17546
LED
Color Status
Meaning
ATTACK
Red
OFF
ON
The module is not attacked.
The module is attacked.
The module is in standby mode.
ACT
ALM
RUN
Green OFF
Blinking The module is in active mode.
Red
OFF
ON
There is no link alarm.
There is a link alarm.
The module is faulty.
Green OFF
Blinking The module operates normally.
Available cables
1000BASE-X SFP ports.
3CR1754766 IPsec Technical specifications
Module
The 3CR1754766 IPsec Module provides eight Gigabit SFP optical ports.
Table 63 Technical specifications for the 3CR1754766
Item
Specifications
BCM1250
512 KB
CPU
Boot ROM
Application Modules
45
Table 63 Technical specifications for the 3CR1754766
Item
Specifications
512 MB
366.7 x 340 mm (14.4 x 13.4 in.)
SDRAM
Physical dimensions (W x D)
Front panel
Figure 31 Front panel of the 3CR1754766
The 3CR1754766 provides eight 1000Base-X ports, one Console port, one AUX
port, three 10/100Base-TX ports and four status LEDs (ATTACK, ACT, ALM and
RUN) from left to right on the front panel.
Table 64 Status LEDs on the 3CR1754766
LED
Color Status
Meaning
ATTACK
Red
OFF
ON
The module is not attacked.
The module is attacked.
The module is in standby mode.
ACT
ALM
RUN
Green OFF
Blinking The module is in active mode.
Red
OFF
ON
There is no link alarm.
There is a link alarm.
The module is faulty.
Green OFF
Blinking The module operates normally.
Available cables
1000BASE-X SFP ports.
3C17548 VPLS Technical specifications
Application Module
The 3C17548 Virtual Private LAN Service (VPLS) Application Module provides no
I/O ports.
Table 65 Technical specifications for the 3C17548
Item
Specifications
CPU
MPC755
Boot ROM
512 KB
SDRAM
512 MB
Physical dimensions (W x D)
366.7 x 340 mm (14.4 x 13.4 in.)
46
CHAPTER 2: I/O AND APPLICATION MODULES
Front panel
Figure 32 Front panel of the 3C17548
Transceivers
Table 66 Transceiver Specifications
Optical Power Range (dBm)
Model
3Com Transceiver
Name
Ordering
Number
Cable Core Size Bandwidth Transmission Wavelength
Type
(microns) (MHz - Km) Range
(nm)
Output
Input
Connector
XENPAKs
3Com 10GBASE-LR
XENPAK
3CXENPAK92
3CXENPAK94
3CXENPAK96
SMF
MMF
SMF
9
50
9
–
2,000
–
2 m – 10 km
(6.6 ft – 6 mi)
1,300
850
-8.2 to 0.5
-14.4 to
0.5
SC
LC
SC
3Com 10GBASE-SR
XENPAK
2 m - 300 m
(3.2 ft - 990 ft)
-7.3 to
-1.3
-11.1 to
-1.0
3Com 10GBASE-ER
XENPAK
2 m – 40 km
(6.6 ft – 25 mi)
1,550
-4.7 to 4
-15.8 to -1
XFPs
3Com 10GBASE-LR XFP 3CXFP92
SMF
9
62.5
62.5
50
–
160
200
400
500
2,000
–
2 m – 10 km
(6.6 ft – 6 mi)
1,300
-8.2 to 0.5
-14.4 to
0.5
LC
3Com 10GBASE-SR XFP 3CXFP94
MMF
MMF
MMF
MMF
MMF
SMF
0.5 – 26 m
(1.7 – 85 ft)
0.5 – 33 m
(1.7 – 108 ft)
0.5 – 66 m
(1.7 – 217 ft)
-4.0 to
-1.1
850
-9.9 to -1.0
-15.8 to -1
LC
LC
50
0.5 – 100 m
(1.7 – 328 ft)
50
0.5 – 300 m
(1.7 – 984 ft)
3Com 10GBASE-ER XFP 3CXFP96
9
2 m – 40 km
(6.6 ft – 25 mi)
1,550
-4.7 to 4
1000 Mbps SFPs
3Com 1000BASE-SX
SFP
3CSFP91
MMF
MMF
MMF
MMF
MMF
MMF
MMF
SMF
62.5
62.5
50
50
62.5
50
50
9
160
200
400
500
500
400
500
–
2 – 220 m
(6.6 – 721 ft)
2 – 275 m
(6.6 – 902 ft)
850
-9.5 to 0
-17 to 0
LC
2 – 500 m
(6.6 – 1,640 ft)
2 – 550 m
(6.6 – 1,804 ft)
3Com 1000BASE-LX
SFP
3CSFP92
2 – 550 m
(6.6 – 1,804 ft)
2 – 550 m
(6.6 – 1,804 ft)
1,300
-9.5 to -3
-20 to -3
LC
2 – 550 m
(6.6 – 1,804 ft)
2 m – 10 km
(6.6 ft – 6 mi)
3Com 1000BASE-LH70 3CSFP97
SFP
SMF
9
–
2 m – 70 km
1,550
–
0 to 3
–
-24 to -3
–
LC
(6.6 ft – 43 mi) ft
3Com 1000BASE-T SFP 3CSFP93
CAT5
–
–
100 m (328 ft)
RJ-45
Switch 8800 Port Densities
47
Switch 8800 Port
Densities
maximum port densities, and whether or not the module supports MPLS or IPv6.
Table 67 Switch 8800 Available Modules
Max Port
Density*
Fabric
SKU
Description
MPLS
No
No
No
No
No
Yes
No
Yes
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
IPv6
No
Adapters
3C17511
3C17512
3C17513
3C17514
3C17516
3C17525
3C17526
3C17527
3C17528
3C17530
3C17531
3C17532
3C17533
3C17534
3C17536
3C17537
3C17538
3C17542
3C17546
3CR1754766
3C17548
1-port 10GBASE-X (XENPAK)
2-port 10GBASE-X (XFP)
12
1
2
1
2
2
1
2
2
1
2
2
1
2
2
4
2
1
1
1
1
1
24
No
12-port 1000BASE-X (SFP)
144
288
288
12
No
24-port 1000BASE-X (SFP)
No
24-port 10/100/1000BASE-T (RJ-45)
1-port 10GBASE-X (XENPAK) Advanced
4-port 10GBASE-X (XFP)
No
No
48
No
2-port 10GBASE-X (XFP) Advanced
48-port 10/100/1000 BASE-T (RJ-45)
24-port 1000BASE-X (SFP) Advanced
24-port 10/100/1000BASE-T (RJ45) Advanced
48-port 10/100/1000BASE-T (RJ45) Access
24-port 1000BASE-X (SFP) IPv6 Module
24-port 10/100/1000BASE-T (RJ-45) IPv6 Module
4-port 10GBASE-X (XFP) QUAD IPv6
2-port 10GBASE-X (XFP) IPv6
48-port 1000BASE-X (SFP) IPv6
Network Monitoring Module
Firewall Module
24
No
576
288
288
576
288
288
48
Yes**
No
No
Yes**
Yes**
Yes**
Yes**
Yes
24
576
Yes**
No
8
8
No***
No***
No
IPsec Module
Virtual Private LAN Service (VPLS)
*Maximum port densities stated for largest chassis model, the Switch 8814 (14
slots)
**IPv6 capable hardware module; advanced software upgrade required for IPv6
routing.
*** The Firewall, IPsec, and VPLS Modules do not support IPv6 in the first IPv6
release.
48
CHAPTER 2: I/O AND APPLICATION MODULES
INSTALLATION PREPARATION
3
Safety
Recommendations
To avoid possible bodily injury and device impairment, please read the following
safety recommendations carefully before installing the Switch 8800 Family. The
recommendations do not cover every possible hazardous condition.
General Safety
Recommendations
■
The Switch 8800 Family use redundant PSUs. Turn off all PSUs and remove all
the power cords before opening the chassis.
■
■
Keep the chassis clean and dust-free.
Keep the chassis and installation tools away from walk areas.
Safety
Recommendations
against Electricity
■
■
Look carefully for possible hazards in your work area, such as ungrounded
power extension cables, missing safety grounds, and moist floors.
Locate the emergency power-off switch in the room before installation. Shut
the power off at once in case accident occurs.
■
■
■
Unplug all the power cords and external cables before moving the chassis.
Do not maintain the equipment alone when it has been powered.
Never assume but check each time that power has been disconnected from a
circuit.
■
Do not place the switch on a moist area and avoid liquid flowing into the
switch.
Safety The Switch 8800 Family are rather big and heavy, so follow the recommendations
Recommendations in below when moving it.
Moving the Switch 8800
Family
■
Remove all the external cables (including power cords) before moving the
chassis.
■
■
■
Do not move the switch alone. Work with another person.
Move the switch slowly and stably. Never move suddenly or twist your body.
Move the switch at stable and consistent paces with your peer. Keep balance of
your body.
CAUTION: You can only hold the handles at both sides of the chassis when
moving the switch, but not the plastic panel of the chassis, the handle of the fan
frame, the handle of the PSUs or the air vents of chassis.
c
As these parts are not designed for bearing the weight of the entire chassis, any
attempt trying to carry the switch with these parts may impair the switch and even
injure yourself.
50
CHAPTER 3: INSTALLATION PREPARATION
Wearing an To prevent the electronic components from being damaged by the electrostatic
ESD-Preventive Wrist discharge (ESD), take ESD measures for the area where the switch is located and
Strap note the issues below:
■
■
Always wear an ESD-preventive wrist strap when installing the parts, especially
the electric printed circuit boards.
Hold the circuit board by the edge. Do not touch the components or the
electric printed circuit.
Take the following steps to use the ESD-preventive wrist strap.
Step 1: Wear the wrist strap on your wrist.
Step 2: Lock the wrist strap tight around your wrist to keep good contact with the
skin.
Step 3: Insert it into the hole peculiar to ESD-preventive wrist strap in the chassis
or attach it to the grounding screw of the chassis the alligator clips.
Step 4: Make sure that the ESD-preventive wrist strap is well grounded.
CAUTION: For the sake of safety, check the resistance of the ESD-preventive wrist
strap. The resistance reading should be in the range of 1 to 10 Mohm between
human body and the ground.
c
Safety Some I/O modules of the Switch 8800 Family have optical interfaces. In operating
Recommendations status, it is dangerous to stare into the open optical interface because the laser
against Laser being transmitted through the optical fiber produces a small beam of light which
has very high power density and is invisible to human eyes; when a beam of light
enters the eye, retina may be burned.
CAUTION: The laser inside the optical fiber may hurt your eyes.
c
Examining Installation
Site
The Switch 8800 Family can only be used indoors. To ensure that the switch works
normally and to prolong its service lifetime, the following requirements should be
met in terms of installation environment.
Temperature/Humidity To ensure the normal operation and service lifetime of a switch, proper
Requirements temperature and humidity should be maintained in the equipment room.
Long-lasting high humidity in the equipment room is prone to poor insulation or
even leakage of the insulating material. Sometimes, the mechanical performance
deterioration, the rustiness and corrosion of some metal parts are also more likely
to occur. If the relative humidity is too low, the captive screws may become loose
due to the insulation washer contraction. Meanwhile, the electrostatic is likely to
be produced in the dry environment, which will jeopardize the CMOS circuit of the
switch. The higher the temperature, the greater the damage it will do to the
switch. Long-lasting high temperature will speed up the aging process of the
insulating materials, greatly lower the reliability of the switch, and therefore affect
its service life seriously.
Examining Installation Site
51
Cleanness Requirements Dust is a hazard to the operating safety of the switch. The indoor dust
accumulated on the chassis can cause electrostatic absorption, which may result in
the poor contact of the connector or metal contact point. This happens more
frequently when indoor relative humidity is low, which will not only shorten the
service life of the switch, but also cause communication failure.
The required specifications on dust content and particle diameter in an equipment
room are shown in the following table.
Table 68 Limitation on dust content in equipment room
Mechanical active material Unit
Content
Dust particle
particles/m3
‚≤3 x 104
(No visible dust on desk in three days)
Note: Dust particle diameter ‚≥ 5µm
Besides the dust specifications, the equipment room of the switch should also
meet the rigorous requirements for the content of salt, acid and sulfide in the air.
These harmful gases could accelerate the metal erosion and the aging process of
some parts. Incursion of harmful gases, such as SO2, H2S, NO2, NH3, and Cl2,
should be prevented. The specific limitation values of these harmful gases are
given in the following table.
Table 69 Harmful gas limits in an equipment room
Gas
SO2
H2S
NO2
NH3
Cl2
Average (mg/m3)
Max. (mg/m3)
0.3
1.0
0.5
0.15
3
0.1
0.004
1.0
0.1
0.3
Anti-Static Any possible interference sources, no matter outside or inside the system, affect
Requirements the switch in use in a way of capacitive coupling, inductive coupling,
electromagnetic radiation, common impedance (including the grounding system)
coupling or conducting line (power line, signaling line and transmission line etc.).
To prevent the interference, you should:
■
Take effective measures against electrical net interference for power supply
system.
■
Separate the working ground of the switch from the grounding device of the
power supply equipment or lightning-protection grounding device as far as
possible.
■
■
Keep the switch far away from the radio launcher, radar launcher, and
high-frequency devices working in the high current.
Adopt electromagnetic shielding if necessary.
Grounding A good grounding system is not only the basis essential to the stable and reliable
Requirements switch operation, but also an important guarantee of lightning protection,
anti-interference and ESD-prevention. The user must provide good grounding
system for the switch.
52
CHAPTER 3: INSTALLATION PREPARATION
Power Supply The Switch 8800 Family adopts redundant PSUs for AC PSU:
Requirements
Rated voltage: 100 VAC to 240 VAC, 50 Hz or 60 Hz
Maximum tolerance: 90 VAC to 264 VAC, 50 Hz or 60 Hz
Maximum power output: 1200 W (Switch 8807)/2000 W (Switch 8810/Switch
8814)
Space Requirements For the sake of adequate ventilation and easy equipment maintenance, you are
recommended to keep one meter of clearance between the rear/front of the
switch cabinet and the wall surface or other devices. If the optional cabinet is
desired, the clear height of the equipment room must be more than 3 meters
inclusive.
Cabinet-Mounting Before cabinet-mounting the switch, make sure that the cabinet meets the
Requirements following requirements:
■
■
■
Better mount the switch in an open cabinet. However, if you want to mount it
in a closed cabinet, make sure of the availability of a good ventilation system.
Make sure that the cabinet stands steadily enough to support the weight of the
switch and the accessories.
Make sure that the switch fits the cabinet size. Leave some clearance beside
the left and right panels of the switch for chassis ventilation.
Installation Tools
Table 70 Required installation tools
Long tape, ruler (1 meter in length), marking pen, powder
marker, pencil
Measure and
lineation tools
One percussion drill, several drill bits, one vacuum cleaner
Flat-module screwdriver P4 -- 75 mm
Drills
Phillips screwdriver P1 -- 100mm, P2 -- 150mm and P3 --
250mm
General
tools
Fastening tools
Socket wrench M5
Box-end wrench M6
Double ring spanner (10-12) or open-end wrench (10-12)
Sharp-nose pliers, diagonal pliers, vices, hand-held electric
drill, file, handsaw, crowbar, rubber hammer
Small tools
Brush, tweezers, paper knife, hand bellows, electric iron,
solder wire, fork, ladder
Auxiliary tools
ESD-preventive wrist strap, cable stripper, crimping pliers,
RJ-45 crimping pliers, wire punchdown tool
Special tools
Meters
Multimeter, 500V Meg-ohmmeter (used for measuring the
insulation resistance), error detector, optical power meter,
earth resistance tester
The instruments and tools are not shipped with the Switch 8800 Family and it is
up to the users to ensure their availability.
n
SWITCH INSTALLATION
4
The Switch 8800 Family shall be installed indoors in a fixed place.
Confirming
Installation
Preparation
■
■
Make sure that you have read Chapter 3 Installation Preparation carefully.
All requirements mentioned in Chapter 3 Installation Preparation have been
met.
Installation Flow
Figure 33 Installation Flow
Start
Confirm preparations
Check installation site
Install cabinet
Install chassis and
other components
Connect PGND wire/power cord
Power distribution box in cabinet
Cabling rack and fan tray
Insert I/O modules or
Application modules
Connect cables to I/O modules
or Application modules
54
CHAPTER 4: SWITCH INSTALLATION
Mounting the Switch
in User-Supplied
Cabinet
Cabinet Configuration
Guideline
CAUTION:
c
■
■
■
Even if no PoE external power supply is installed, it is recommended that you
reserve the PoE power supply slot (just cover a 4 U blank filler panel) in the
cabinet for later PoE expansion.
For components of 4 U or higher, such as chassis and PoE power supply, more
screws are required to secure the slide rails in the cabinet considering their
weight.
You can adjust the specific height of every slot as needed. The following
guideline is just for reference.
One Switch 8807 chassis in a cabinet
The components and their height are as follows (from bottom up):
■
■
■
Blank filler panel (2U)
Cabling frame (2U)
External PoE power supply (or blank filler panel if no external PoE power supply
is installed) (4U)
■
■
■
■
■
Blank filler panel (1U)
Back cabling frame (1U)
New Switch 8807 chassis (11U)
Blank filler panel (1U)
Cabling frame (2U)
Mounting the Switch in User-Supplied Cabinet
55
Figure 34 One Switch 8807 chassis in a cabinet
Switch 8807 11U
(1) Blank filler panel
(3) Backward cabling frame
(2) Cabling frame
(4) Reserved for external PoE power supply
at your disposal.
Two Switch 8807 chassis in a cabinet
The components and their height are as follows (from bottom up):
■
■
■
Blank filler panel (2U)
Cabling frame (2U)
External PoE power supply (or blank filler panel if no external PoE power supply
is installed) (4U)
■
■
■
■
■
■
Blank filler panel (1U)
Back cabling frame (1U)
Switch 8807 chassis (11U)
Blank filler panel (1U)
Cabling frame (2U)
Switch 8807 chassis (11U)
56
CHAPTER 4: SWITCH INSTALLATION
Figure 35 Two Switch 8807 chassis in a cabinet
Switch 8807 11U
Switch 8807 11U
(1) Blank filler panel
(2) Cabling frame
(3) Backward cabling frame
(4) Reserved for external PoE power supply
at your disposal.
One Switch 8810 chassis in a cabinet
The components and their height are as follows (from bottom up):
■
■
■
Blank filler panel (2U)
Cabling frame (2U)
External PoE power supply (or blank filler panel if no external PoE power supply
is installed) (4U)
■
■
■
■
■
Blank filler panel (1U)
Back cabling frame (1U)
Switch 8810 chassis (14U)
Blank filler panel (1U)
Cabling frame (2U)
Mounting the Switch in User-Supplied Cabinet
57
Figure 36 One Switch 8810 chassis in a cabinet
Switch 8810 14U
(1) Blank filler panel
(2) Cabling frame
(4) Reserved for external PoE power supply
(3) Backward cabling frame
at your disposal.
One Switch 8814 chassis in a cabinet
The components and their height are as follows (from top down):
■
■
■
Blank filler panel (2U)
Cabling frame (2U)
External PoE power supply (or blank filler panel if no external PoE power supply
is installed) (4U)
■
■
■
■
■
Blank filler panel (1U)
Back cabling frame (1U)
Switch 8814 chassis (17U)
Blank filler panel (1U)
Cabling frame (2U)
58
CHAPTER 4: SWITCH INSTALLATION
Figure 37 One Switch 8814 chassis in a cabinet
Switch 8814 17U
(1) Blank filler panel
(2) Cabling frame
(3) Backward cabling frame
(4) Reserved for external PoE power supply
at your disposal.
Mounting the Switch in Take the following steps to install the Switch 8800 Family in a 19-inch cabinet.
the Cabinet
Step 1: Confirm before installation
■
Make sure that the cabinet has been well fixed. The layout inside the cabinet
for switch installation has been well done and there is no obstruction inside or
around the cabinet.
■
Make sure that the switch is ready for installation and has been carried to a
place convenient for further moving near the cabinet.
Step 2: Mount a shelf inside the cabinet depending on the position where you
want to put the switch.
Step 3: Install the cabling rack and attach the mounting ears shipped with the
switch onto the switch.
Step 4: Carry the switch at both sides with another person to the place in front of
the cabinet slowly.
Step 5: Lift the switch a little higher than the cabinet shelf, put it on the shelf, and
push it into the cabinet.
Connecting PGND Wire and Power Cord
59
Step 6: Align the mounting ears with the square holes in the posts of the cabinet,
and fasten the screws in the holes to fix the switch in the cabinet.
Connecting PGND
Wire and Power Cord
Connecting PGND Wire
CAUTION: For the safety of operators and equipment, the switch must be well
grounded. The resistance reading between switch chassis and the ground must be
less than 1 ohm.
c
Common grounding environment
Step 1: Remove the screw from the grounding hole in the switch chassis.
Step 2: Wear the connector of the PGND wire accompanied with the switch on
the grounding screw.
Step 3: Insert the grounding screw into the grounding hole and screw it down.
Step 4: Connect the other end of the ground wire to the ground bar of the switch.
Generally, the cabinets installed in equipment rooms are equipped with ground
bar. In this case, you can connect the PGND wire of the switch to the ground bar
for it.
n
n
Other grounding environment
Following are some methods for grounding the switch in different grounding
environments that you are likely to encounter when installing the switch at
different places.
Rather than specifying the switch model or showing the actual location of the
switch power input or grounding screw, the following figures are primarily
intended for illustrating the switch grounding, either via grounding screw or
power input, in specific grounding environments.
■
If a ground bar is available, attach one end of the yellow-green PGND wire of
the switch to a grounding bolt of the ground bar and fasten the captive nuts.
Note that the fire main and lightning rod of a building are not suitable for
grounding the switch. The PGND wire of the switch should be connected to
the grounding device in the equipment room. (For the Switch 8800 Family, the
60
CHAPTER 4: SWITCH INSTALLATION
Figure 38 Ground the switch when ground bar is available
5
˄ ˅
1
˄ ˅
2
˄ ˅
3
˄ ˅
4
˄ ˅
(1) Air filter
(2) Grounding screw
(3) PGND wire
(4) Ground bar of the equipment room
(5) Rear panel of the switch
■
If there is no ground bar but earth nearby and the grounding body is allowed
to be buried, you can simply hammer an angle iron or steel pipe no shorter
than 0.5 m into the earth. In this case, the yellow-green PGND wire should be
welded with the angle iron (steel pipe) and the joint should be processed
against eroding. (For the Switch 8800 Family, the grounding screw is on the
Figure 39 Ground the switch when allowed to bury grounding body nearby
˄6˅
˄1˅
˄2˅
˄3˅
˄4˅
˄5˅
(1) Air filter
(2) Grounding screw
(3) PGND wire
(5) Angle steel
(4) Ground bar of the equipment room
(6) Rear panel of the switch
■
If both ground bar and the conditions for burying the grounding body are not
available, an AC-powered Ethernet switch can be grounded using the PE wire
of the AC power supply. In this case, make sure that the PE wire of the AC
Connecting PGND Wire and Power Cord
61
power supply has been well grounded at the power distribution room or AC
power supply transformer side.
Figure 40 Ground the switch via AC PE wire
(7)
(6)
(5)
(1) (2)
(3)
(4)
(1) Live line
(3) PE line
(2) Neutral line
(4) 3-core AC input cable
(6) AC power input
(5) Transformer
(7) Front panel of the switch
Connecting AC Power
Cord
CAUTION:
c
■
For lightning protection, the AC power should be led through an external
lightning device into the switch.
■
Make sure the power switch on the PSU is at OFF position before connecting
the power cord.
On the front panel of AC PSU, there is a plug-retention clamp.
Take the following steps to connect the AC power cord (coming with the switch)
to the Switch 8807/Switch 8810/Switch 8814:
Step 1: Turn the clamp at the left of the PSU front panel to the right.
Step 2: Insert the plug at one end of the AC power cord into the socket on the
PSU.
Step 3: Turn the clamp to the left until it grips the plug.
Step 4: Insert the other end of the power cord into an external power socket.
62
CHAPTER 4: SWITCH INSTALLATION
Figure 41 Connect AC power cord to the Switch 8807
(5)
(1) Connector-retention clamp
(2) Input LED
(4) Fail LED
(3) Output LED
(5) Power switch
Figure 42 Connect AC power cord to the Switch 8810/Switch 8814
(1)
(2)
(3)
(4)
(5)
(1) Connector-retention clamp
(3) Output LED
(2) Input LED
(4) Fail LED
(5) Power switch
Connecting PGND Wire and Power Cord
63
Connecting PoE Power The Switch 8807/Switch 8810/Switch 8814 uses PSE4500-A external PoE power
Cord supply, which is connected to the switch through the PoE module at the front
bottom of the switch to provide power to PDs (powered devices) under the switch.
This section only focuses on the cable connection between the external PoE
power supply and the Switch 8800 Family switch. For the installation of the
external PoE power supply, see the manual shipped with the power supply.
n
Grounding PoE chassis
You must ground the PoE chassis before connecting the PoE power cord to it.
Follow these steps:
Connect the 6 AWG cable of the wiring terminal (with M6 hole) to the grounding
Connect the other end of the cable to the grounding bar or other grounding
terminals.
Figure 43 Ground PoE chassis
(1) Chassis grounding screw
Connecting PoE power cable
Loosen the mounting screw of the PoE entry module with a cross screwdriver.
Insert the -48V OT terminal (blue) of the DC power cord to the NEG (-) terminal of
the PoE entry module and fasten the mounting screw; insert the other end to the
NEG (-) terminal of the external PoE power supply.
Insert the GND OT terminal (black) of the DC power cord to the RTN (+) terminal
of the PoE entry module and fasten the mounting screw; insert the other end to
the NEG (-) terminal of the external power supply.
CAUTION:
c
■
Observe the signs on devices and connect the cables correctly.
Choose right cables based on the load.
■
64
CHAPTER 4: SWITCH INSTALLATION
Figure 44 Front panel of external PoE Power Rack (3C17509)
(1) DC output terminal: NEG(-)
(3) AC input switch
(2) DC output terminal: RTN(+)
(4) AC input socket
Installing Cabling Rack For your convenience, cabling racks are shipped with the Switch 8800 Family. Take
the following steps to install the rack.
Step 1: Face the I/O module slots of the switch;
Step 2: Attach the left mounting ear (the one with an elliptical hole on one surface
and a recessed hole on the other) onto the cabling rack and fix it with screws (one
cabling rack for Switch 8807/Switch 8810 and two for Switch 8814);
Step 3: Install mounting ears onto the both sides of the switch.
Figure 45 The position of the cabling rack
Installing Fan Tray
The fan tray is hot swappable.
Installing PoE Lightning Protection Box
65
CAUTION: In case of bodily injuries, do not touch any naked wire, terminal or
other parts of the product with hazardous voltage labels.
c
Step 1: Wear the ESD-preventive wrist strap, making sure that it makes good skin
contact; take the fan tray out from the packing bag.
Step 2: Hold the fan tray in right direction (just check the direction of instructional
words, and if you insert it upside down, the plug of the fan tray cannot touch the
right socket inside the chassis), with one hand on its handle and the other hand at
its bottom the ejector levers on the fan tray with both hands and pull them
outward. Align the fan tray with the guides in the chassis and slide it gently into
the slot until its plug touches the chassis socket.
Step 3: Fasten the mounting screws on the panel of the fan tray with a screw
driver.
The above installation steps are just for replacing your fan tray, since the fan tray
is delivered together with the chassis and no initial installation is required.
n
Installing PoE
The 3C17510 PoE Entry Module is hot-swappable.
Lightning Protection
Box
CAUTION: Do not touch any exposed wires, terminals, and device parts marked as
hazard to avoid hurting your body.
c
1 Wear an ESD-preventive wrist strap and ensure it is well grounded. Unpack the
Figure 46 PoE Entry Module
2 Keep the PoE Entry Module in the right direction, that is, correct letter direction
(do not turn it upside down, or you will not be able to fully insert it into the chassis
due to the limitation on the back structure of the box, nor can you fasten the
chassis fixing screw), hold it with one hand at the bottom and with another hand
66
CHAPTER 4: SWITCH INSTALLATION
at the front panel, and then slide it smoothly along the guide rail to the slot, until
it fits into the chassis, with its plug fully touching the socket inside the chassis. See
Figure 47 Install PoE lightning protection box
3 Fasten the screw on top of the PoE lightning protection box.
Generally, the PoE lightning protection box is shipped with the chassis of the
switch you ordered. So you need not to install the box. The above installation
procedure is needed only when you are changing the fan frame.
n
Installing I/O modules
The I/O modules of the Switch 8800 Family are hot-swappable.
Step 1: Wear the ESD-preventive wrist strap, making sure that you have grounded
it well. Take the I/O module out of the packing bag.
Step 2: Unscrew the mounting screws holding the blank filler panel in the slot
where you plan to install the I/O module, and remove the panel from the slot.
Step 3: Hold the ejector levers on the fan tray with both hands and pull them
outward. Align the I/O module with the guides in the chassis and slide it gently
into the slot until the positioning pin of the I/O module touches the hole in the
chassis.
Step 4: Pull the ejector levers inward, locking the positioning pin into the hole.
Step 5: Fix the I/O module by fastening the mounting screws on the I/O module
with a screw driver.
Put the removed blank filler panel away for future use.
n
For the Switch 8800 Family, the Application Module can be installed in the I/O
module slot in the same way as installing the I/O module board.
Connecting Interface Cables
67
Connecting Interface
Cables
Connecting Console Introduction
Cable
Console cable is an 8-core shielded cable. At one end of the cable is a crimped
RJ-45 connector that is to be plugged into the console port of the switch. At the
other end of the cable are a DB-9 (female) connector and a DB-25 (female)
connector. You can plug either of them into the 25-pin (male) or 9-pin (male) serial
port on the console terminal as needed. The following figure illustrates the
console cable.
Figure 48 Console cable
Enlarged A side
Pos. 25
DB 25 Female
8P8C Plug
Enlarged B side
A
B
Pos.8
Pos.1
DB9 Female
Enlarged C side
Pos.1
C
Pos.1
Pos.9
Table 71 Console cable pinouts
RJ-45
Signal
RTS
Direction
DB-25
DB-9
1
2
3
4
5
6
7
8
←
←
←
→
−
4
7
4
3
1
5
2
6
8
DTR
TXD
CD
20
2
8
GND
RXD
DSR
CTS
7
→
→
→
3
6
5
Connecting console cable
Take the following steps to connect the console cable, when configuring the
switch on the terminal.
Step 1: Plug the DB-9 or DB-25 female connector of the console cable into the
serial port of the PC/terminal where the switch is to be configured.
Step 2: Connect the RJ-45 connector of the console cable to the console port of
the switch.
68
CHAPTER 4: SWITCH INSTALLATION
The PC serial port is not hot-swappable, so you are not allowed to insert or
remove the console cable into or from the PC serial port.
n
When connecting the console cable, first connect the DB9/DB25 end to the PC
serial port and then the RJ45 end to the console port of the switch. And removing
the console cable is just in inverse order.
When removing the console cable, first remove the RJ-45 end and then the
DB9/DB25 end.
Connecting AUX Cable You need an AUX cable when configuring the Switch 8800 Family with the remote
modem dial-up approach.
Introduction
AUX cable is an 8-core shielded cable. At one end of the cable is an
RS-232-compliant RJ-45 connector that can be plugged into the console port of
the switch. At the other end are DB-9 (male) connector and DB-25 (male)
connector. You can plug either of them into the DB-9 (female) or DB-25 (female)
port of the modem as needed. The following figure illustrates the AUX cable.
Figure 49 AUX cable
Enlarged A side
Pos.1
DB25 Male
8P8C PLUG
Enlarged B side
Label
B
A
Pos.1
Pos.8
Enlarged C side
Pos.9
DB9 Male
Pos.25
C
Pos.1
Table 72 AUX cable pinouts
RJ-45
Signal
RTS
Direction
DB-25
DB-9
1
2
3
4
5
6
7
→
→
→
←
-
4
7
4
3
1
5
2
6
DTR
TXD
CD
20
2
8
GND
RXD
DSR
7
←
←
3
6
Connecting Interface Cables
69
Table 72 AUX cable pinouts
RJ-45
Signal
Direction
DB-25
DB-9
8
CTS
←
5
8
Connecting AUX cable
Step 1: Plug the RJ-45 connector of the AUX cable into the AUX port of the
switch.
Step 2: Plug the DB-25 (male) or DB-9 (male) connector at the other end into the
serial port of the analog modem.
Connecting Category-5 Introduction to RJ-45 connector
Shielded Cable
Being RJ-45 connector, the 10Base-T/100Base-TX port of the Switch 8800 Family
supports MDI/MDIX auto-sensing and will be connected using the category-5
shielded cable. The following figure illustrates an RJ-45 connector.
Figure 50 RJ45 connector
PIN #8
PIN #1
Connecting category-5 shielded cable
Step 1: Plug one end of the network cable into the desired Ethernet RJ-45
connector on the switch.
Step 2: Plug the other end of the cable into the RJ-45 port of the peer device.
Connecting Fiber
All the megabit and gigabit optical modules available for the Switch 8800 Family
are SFP modules that provide LC user ports.
n
Introduction to fiber connector
■
When selecting a fiber network facility, make sure that the type of the
connector and the fiber match the adopted optical port.
n
■
Before connecting the fiber, make sure that the receive-end optical power does
not exceed the upper threshold of the receiving optical power. Excessive
receiving optical power is very likely to burn the optical module.
Fiber connectors are indispensable passive components in an optical fiber
communication system. Their application allows the removable connection
between optical channels, which makes the optical system debugging and
maintenance more convenient and the transit dispatching of the system more
flexible. Among various fiber connectors, only LC connector will be introduced
here.
■
LC fiber connector
70
CHAPTER 4: SWITCH INSTALLATION
Figure 51 LC connector
Connecting fiber
Step 1: Plug one end of the fiber into the SFP optical module of the Switch 8800
Family.
Step 2: Connect the other end of the fiber into the corresponding device.
CAUTION: When the optical interface has not been connected with a fiber
connector or its dust-proof mesh is open, there might be some invisible radiation
emitted from the optical interface. So do not look into the optical interface
directly.
c
Cover the optical interface if there is no connector plugged in.
Cable Routing
Recommendations
Freestanding Switch on For only selling an integrated chassis, you do not have to care about the cabling
Tabletop inside or outside the cabinet. All the I/O module cables are routed from the left
side of the chassis (along the cabling channel), and the chassis power cords
(AC/DC power cords) are routed in the front of the chassis.
Cabinet-Mounting If the switch is mounted in a 19-inch standard cabinet or B68-22 cabinet, the I/O
Switch module cables are bound on the cabling rack at the left side of the chassis and are
routed up or down to pass through the chassis top or the raised floor depending
on the available equipment room condition (that is, the signal cables are routed
into the chassis either from the cabling rack on the chassis top or from the cabling
trough under the floor) of the exchange office. The power cords run along the
left-front of the chassis and out of the chassis either from the top or the raised
floor depending on the equipment room conditions (DC power distribution
cabinet, lightning protection box, and terminal block, etc.) of the exchange office.
Cable Management
Cable Management
Requirements
■
Bundle and put the cables inside the cabinet in a straight and neat way. No
intertwinement or bending is allowed.
Cable Management
71
Figure 52 Cable bundling example I
Intertwined
Bent
■
■
The bending radius of cable body cannot be less than twice of the cable
diameter. The bending radius of the cable cannot be less than 5 times of its
diameter at the place where it is led out of the connector;
Different cables (power cord, signal cable, PGND wire, etc.) should be cabled
and bundled separately rather than together in the cabinet. If they are close to
each other, you can cable them in cross-shape. For parallel cabling, the space
between power cord and signal cable should be no less than 30 mm (1.2 in);
■
■
■
The cable binding rack and cabling channel inside and outside the cabinet
should be smooth and without sharp edges or tips;
The metal cable management hole should have a smooth and fully rounded
surface or wear a insulating bush;
Use the right type of ties to bundle the cables. Do not bundle cables with
joined ties. 3Com Corporation provides the following types of ties: 100 x 2.5
mm (3.9 in x 0.1 in), 150 x 3.6 mm (5.9 x 0.1 in), 300 x 3.6 mm (11.8 x 0.1 in),
530 x 9 mm (20.9 x 0.4 in), and 580 x 13 mm (22.8 x 0.5 in);
■
Cut the extra parts of the ties neatly after bundling the cables, leaving no sharp
or angular tips. See the following figure:
Figure 53 Cable bundling example II
72
CHAPTER 4: SWITCH INSTALLATION
■
Bundle the cables wherever cable bending cannot be avoided. However, the
cable ties cannot be placed inside the bending area in case of the likelihood of
cable core break due to excessive stress. See the following figure.
Figure 54 Cable bundling example III
■
The spare cables or excessive cable parts should be folded and bundled and
placed at a right place in the cabinet or on the cabling channel. A “right place”
refers to the place where the cables will not affect the operation of the device
or impair the device, or be damaged;
■
■
The power cords cannot be tied on the guides of any mobile components;
Reserve some redundancy for the cables connecting to the mobile parts, the
PGND wire of the door for example, to free the cables from possible stress.
Such a mobile part should be installed in such a way that the extra cable
segments will be kept from contacting the heat source, sharp points or edges.
Use high temperature cables near the heat sources;
■
For the cable terminals fixed using screw threads, the screws or nuts should be
securely fastened and prevented from loosing. See the following figure;
Figure 55 Cable fixing example
Flat
washer washer
Flat
Spring
washer
Nut
Verifying the Installation
73
■
When using a hard power cord, fix it near its terminal so as to free the terminal
and the cable from stress;
■
■
Do not use tapping screws to fasten the connecting terminals;
The power cords of the same type and in the same direction should be bundled
together and kept neatly and straight;
The following table lists the requirements in the bundling with cable ties.
Table 73 Tie-binding parameters
Cable bundle diameter (mm)
Space between bundles (mm)
80 to 150
10
10 to 30
30
150 to 200
200 to 300
■
No cable or bundle can tie a knot;
■
The metal parts of the crimped cold-pressed terminal blocks (such as air switch)
cannot stretch beyond the blocks.
Verifying the
Installation
CAUTION: Confirm that you have turned off the power before checking,
otherwise, improper connection will hurt people or impair the components of the
switch.
c
After installing the switch, verify the installation by the following list, ensuring all
the checking results are normal.
Table 74 Installation checking list
Item
Normal
Abnormal (Description)
ESD-preventive wrist strap
Console cable
PGND wire
Power cord
fabric
I/O module/Application
Module
Fan tray
PSU
74
CHAPTER 4: SWITCH INSTALLATION
DEBUGGING THE SYSTEM
5
Setting up
Configuration
Environment
Figure 56 Networking environment for switch configuration
Switch
To the console port
To the serial port
Console cable
PC
Connecting the Cables
1 Insert the DB-9 (or DB-25) female connector of the Console cable into the serial
port on the PC (the Console terminal).
2 Insert the RJ-45 connector of the cable into the Console port on the switch.
Setting the Terminal Set baud rate to 9600, data bits to 8, parity check to none, stop bits to 1, flow
Parameters control to none, and terminal emulation to VT100.
This section will tell you how to set the terminal parameters, taking a PC running
Windows 98 Hyper Terminal as an example.
Step 1: Start PC, and run terminal emulation program (such as Terminal of
Windows3.1, or Hyper Terminal of Windows 95/Windows 98/Windows
2000/Windows NT/Windows XP/Windows ME) on PC.
Step 2: Set parameters in the Hyper Terminal of Windows98.
76
CHAPTER 5: DEBUGGING THE SYSTEM
You must set the baud rate to 9600, data bits to 8, no parity check, stop bit to 1,
and flow control to none, and select VT100 for terminal emulation. Specifically,
1 Click Start→Programs→Accessories→Communications→HyperTerminal to
access the Hyper Terminal window. The Connection Description dialog box
displays.
2 Click the red phone icon in the window to set up a new connection.
3 Enter the name of the new connection in the Name field and OK. The Properties
dialog box displays.
4 Select the target serial port to be used in Connect using field, and click OK. The
Port Settings Properties dialog box display.
5 Set the connecting serial interface parameters. Set the bits per second to 9600,
data bits to 8, Parity to None, stop bits to 1, and flow control to None, then click
OK. The HyperTerminal dialog box displays.
6 Select File→Properties to access the 3Com Properties Window.
7 Click the Settings tab, select VT100 for terminal emulation, and click OK to
confirm the settings.
It is recommended that you set the function, arrow, and Ctrl keys to act as
Windows keys.
n
Powering and Booting
the Switch
Verifying Installation You should verify the installation of the switch before powering it on, to make
before Powering the sure that:
Switch
■
■
■
The switch is stable enough.
All the boards have been correctly installed.
All the communication cables, fibers, power cords, and grounding wires are
correctly connected.
■
■
The proper power voltage is used as required by the switch.
The Console cable has been correctly connected, the PC or terminal for
configuration has been in service and all the required terminal parameters have
been set.
CAUTION: Before powering on the switch, locate the position of the power
switch for the equipment room where you will operate so that you can switch off
the power supply promptly if needed.
c
Powering on the Switch
■
■
Turn on the power switch of the power source providing power to the switch.
Turn on the power switch.
Verifying after Power-on To ensure the configuration works that you will make on the switch, you are
(Recommended) recommended to check the switch after powering it on to make sure that:
■
The cooling system is working. In this case, you can hear the noise caused by
fan rotation and feel that there is air exhausted out.
Powering and Booting the Switch
77
■
All the system LEDs on the fabrics function normal.
Boot Interface The Switch 8807 is used as an example in this section.
The following is the information that will be output at the Console terminal when
you power on the switch.
ZBB_TEST
Starting...
******************************************
*
*
* 3Com Switch 8800 Family Bootrom, Version 106
*
*
*
******************************************
Copyright(C) 2001-2005 by 3Com CORPORATION
Creation date: Jun 6 2003, 19:28:01
CPU type
CPU L2 Cache
: MPC755
: 1024KB
CPU Clock Speed : 400MHz
BUS Clock Speed : 100MHz
Memory Size
: 512MB
Flash file system init....done
Switch 8800 Family 3C17508 board self testing.....................
The board is steady
SlotNo of this 3C17508 is 0
BootRom main system CRC check is OK
82559 register testing is OK
EPLD1 testing is OK
EPLD2 testing is OK
16c2552 register testing is OK
Please check LEDs......................LED testing finished
The switch Mac address is 00e0.fc00.00a1
Press Ctrl+B to enter Boot Menu... 0
Auto-booting...
Booting from Flash...
Decompress Image...................................................
.......................................................OK!
Starting at 0x10000...
User interface Con 0 is available
Press ENTER to get started.
The above prompt information appears when the switch completes its boot
sequence. Press Enter to begin configuring the switch.
The Switch 8800 Family provide abundant command views. For more information
about the configuration commands and the Command Line Interface (CLI), see
3Com Switch 8800 Family Routing Switches Operation Manual.
n
78
CHAPTER 5: DEBUGGING THE SYSTEM
SWITCH MONITORING AND
MAINTENANCE
6
Monitoring the Switch Although the Switch 8800 Family has undergone a comprehensive factory test
before delivery, an improper installation may cause problems. This chapter
describes how to troubleshoot the Switch 8800 Family.
Troubleshooting Console If the system running properly, when you power on the switch, you will see the
Terminal boot information on the console terminal. If the switch is configured incorrectly,
the console terminal may display illegible output or nothing at all.
If the console does not display anything after you power on the switch, check that
the:
■
■
■
Power system is working normally.
Fabric is working normally.
Console cable is connected to the console port on the fabric.
If you find no issues with these items, the problem is most likely one of the
following:
■
The console cable is not connected to the right serial port. That is, the port in
use is not the one configured on the terminal.
■
There are console terminal parameter errors. (According to the parameter
setting requirements, you should set the baud rate to 9600, data bits to 8,
parity to None, stop bits to 1, flow control to None, and select VT100 as your
terminal emulation protocol.)
■
The console cable is not in good condition.
If the terminal displays illegible characters, it is most likely a console terminal
setting error. Check that you have set the baud rate to 9600, data bits to 8, parity
to None, stop bits to 1, flow control to None, and select VT100 as your terminal
emulation protocol.
Troubleshooting the PSU
Table 75 LEDs on the PSU
LED
Description
INPUT
It stays ON if the power input is normal and the PSU switch is at the ON position.
It stays OFF if the power input has failed or if there is no power input at all.
OUTPUT
FAIL
It stays ON if the power output is normal, otherwise it is OFF.
It stays ON if the PSU has failed, otherwise it is OFF.
80
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
The following PSU faults may appear on the switch. Follow the instructions
provided to resolve the problem.
Display Power Command Indicates the PSU is Not in Position
The Input LED (green) and Output LED (green) stay ON, but the display power
command shows that the PSU is not in position (but the other PSU operates
normally). This problem is likely caused by a poor connection (badly seated)
between the PSU and the backplane. To correct this:
1 Switch off the power supply
2 Loosen the screws on the PSU
3 Push the PSU into the chassis a little bit
4 Tighten the screws
5 Switch on the power supply to check that the normal state is resumed
The Input LED (green) and Output LED (green) are OFF
Check that the power cords are connected correctly, the power cords are in good
condition, and the power switch has been put in the ON position.
The Fail LED (red) is ON
Check that the:
■
■
Correct power voltage is in use (90 to 264VAC, 50-60 Hz for AC PSU).
Air filter protecting the fan tray is clean. Excessive dust accumulated on the air
filter may block the fan tray from free ventilation and can lead to power supply
failure.
If the problem persists, contact 3Com technical support engineers. Do not
disassemble the PSU yourself.
w
Troubleshooting Fan The Switch 8800 Family provides two LEDs on the fan tray as described in
Table 76 Fan tray LEDs
Indicator State description
RUN
Green indicates that the fan tray is operating normally.
OFF indicates that the fan tray has failed.
ALM
Red indicates that the fan tray has failed.
OFF indicates that the fan tray is in operating normally.
The ALM LED on the fan tray stays ON for two to three seconds when the switch is
powered on.
n
If the RUN LED is OFF, check that:
■
■
The fan tray has been well seated.
All the cables connecting the fan tray to the backplane are connected and are
in good condition.
Hardware Maintenance
81
■
■
■
The fans are working normally.
The rotation of the fans has not been blocked.
The blank filler panels have been inserted into the I/O module slots.
Troubleshooting I/O The Switch 8800 Family provides I/O moduleX LEDs on the fabric so that you can
Module check the state of these I/O modules.
Table 77 I/O Module LEDs
Indicator
State description
RUN
ON indicates an I/O module failure.
OFF indicates that the I/O module has failed or it is not in position
at all.
Blinking indicates that the I/O module is working normally.
ALM
OFF indicates that there is no I/O module alarm or that the I/O
module is not in position at all.
ON indicates that there is an I/O module alarm.
2~6 (Switch 8807)
On the Switch 8807, I/O module 0 through I/O module 4
respectively correspond to slots 2 through 6.
0~3, 6~9 (Switch 8810)
0~5, 8~13 (Switch 8814)
On Switch 8810, I/O module 0 through I/O module 7 respectively
correspond to slots 0 through 3 and 6 through 9.
On Switch 8814, I/O module 0 through I/O module 11 respectively
correspond to Slots 0 through 5 and 8 through 13.
Hardware
Maintenance
Replacing AC PSU
CAUTION: The Switch 8800 Family’s PSU is hot-swappable. Refer to the
document entitled “3Com Switch Family Safety and Regulatory Information,” part
number 10015300, for information about how to install and set up your switch
safely. Also:
c
■
The Switch 8800 Family uses multiple power systems, and you must turn off all
of them when removing the AC PSU.
■
The PSU of the Switch 8800 Family is heavy. Use both hands to pull it out
slowly and gently, with one holding its handle and the other holding its
bottom.
■
If you are not installing a replacement PSU, insert a blank filler panel into the
PSU slot so that dust cannot get into the unit and to allow proper ventilation
Removing an AC PSU
To remove an AC PSU:
1 Change the power switch on the PSU from the ON position into the OFF position.
2 Pull right the clamp holding the power cord connector and unplug the power
cord.
3 Unscrew the screws on the both sides of the PSU panel with a flathead
screwdriver.
82
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
4 Hold the handle of the PSU and pull the PSU gently out of the chassis along the
guides.
Figure 57 Remove and install the AC PSU
Installing an AC PSU
1 Hold the handle of the PSU with one hand and the bottom of the PSU with
another hand, and gently slide the PSU into the chassis along the guides until it is
secure in the backplane.
2 Fasten the screws at both sides of the PSU panel with a flathead screwdriver.
3 Check that the power switch on the panel is in the “OFF” position and the clamp
holding the power cord connector is pulled up.
4 Insert the AC power cord included with the switch into the socket on the PSU.
5 Pull the clamp down to hold the power cord.
Replacing and Cleaning This section describes how to clean and replace the Switch 8800’s AC PSU air filter.
the PCU’s Air Filter
CAUTION: We strongly recommend that you clean the air filter semimonthly to
guarantee adequate ventilation.
c
Removing and cleaning the air filter of PSU
1 Hold the air filter by the upper and lower edges with your index finger and thumb.
2 Gently pull the air filter out of the chassis.
3 Take the black air filter mesh out.
4 Clean and dry (but do not rub) the mesh.
5 Place the dry black mesh back into position.
Hardware Maintenance
83
Figure 58 Remove the air filter of AC PSU
(1) PSU
(2) Air filter
(3) Air filter cover
Installing the air filter of PSU
To install the PCU’s air filter:
1 Ensure that the black mesh is contained within the air filter cover.
Figure 59 Installing the PSU Air Filter
2 Hold the air filter cover by the upper and lower edges with your index finger and
thumb and push it inside the PSU.
Replacing and Cleaning
the Chassis’s Air Filter
CAUTION: We recommended that you clean the air filter semimonthly to
guarantee adequate ventilation.
c
You install the Switch 8800’s air filter at the chassis’s air intake vents. If you do not
clean the air filter often, the accumulated dust blocks the filter’s holes and affects
the chassis’s ventilation. Use one of the following two methods to clean the filter,
but do not rub the air filter when you wash it. Allow it to air dry.
84
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
Removing and Cleaning the Chassis’s Air Filter
1 Unscrew the screws at the top and bottom of the air filter with a flathead
screwdriver.
2 Hold the air filter at the left-rear by its upper and lower edges, pull part of it out of
the chassis, put one hand underneath the air filter to hold it, and pull it out slowly
along the guides.
CAUTION: Because the air filter is rather long, you should hold its front end with
one hand, and bear its weight by putting another hand underneath it when sliding
the air filter out of the chassis.
c
3 Rather than taking the air filter mesh out, directly wash the air filter after removing
it from the chassis, allow it to air dry, and insert it back into the chassis.
Installing the Chassis’s Air Filter
1 Hold the front end of the air filter with one hand and put the other hand
underneath it, align it with the guides, and slide it into the chassis along the
guides.
2 Fix the air filter by fastening the screws at the top and bottom of the air filter with
a flathead screwdriver.
CAUTION: As the air filter is rather long, you should hold its front end with one
hand, and bear its weight by putting another hand underneath it when sliding the
air filter into the chassis.
c
Replacing a Module The Switch 8800’s fabric, I/O modules, and application modules are similar in
structure and you can install and remove them in the same way. This section
describes the general procedures for removing and installing these modules.
The Switch 8800 Family modules are hot-swappable.
Required tools
■
ESD-preventive wrist strap
Screwdriver
■
Removing a Module
To remove a module:
1 Wear the ESD-preventive wrist strap and unscrew the screws on the module with a
flathead screwdriver.
2 Hold the ejector levers on the module with both hands and press them outward to
separate the module’s locking pin from the backplane.
3 Gently pull the module out of the slot along the guides.
Figure 60 Removing a Module
Hardware Maintenance
85
Installing a Module
1 Wear the ESD-preventive wrist strap and unscrew the mounting screws fixing the
blank filter panel in the slot where you want to install the module, and remove the
blank filler panel.
2 Hold the ejector levers of the card with both hands and pull them outward, align
the card with the guides in the chassis, and slide it gently into the slot until its
positioning pin touches the positioning hole in the chassis.
3 Pull the ejector levers inward to lock the positioning pin of the card into the
positioning hole in the chassis.
4 Fasten the screws to fix the card.
Figure 61 Installing a Module
Replacing the Fan Tray
CAUTION: To avoid bodily injury, do not touch exposed wires, terminals, or the
switch parts where a dangerous voltage warning label is indicated.
c
Required tools
■
ESD-preventive wrist strap
Screwdriver
■
Replacing the Fan Tray
To replace the fan tray:
1 Wear the ESD-preventive wrist strap.
2 Remove the screws from both sides of the fan tray.
3 Pull the fan tray out with one hand on the top and the other hand around the
handle of the fan tray to separate the fan tray positioning pin from the backplane.
CAUTION: When you replace the fan tray of an operating switch, pull the fan tray
out from the chassis only after the fans stop rotating. In this case, there is still the
possibility that fans are still rotating. Therefore do not put your hand into the fan
tray to avoid bodily injury.
c
4 Gently pull the fan tray out of the slot along the guides and place fan tray into the
packing bag.
5 Hold the fan tray’s handle with one hand and its bottom with the other and pull
them outward.
6 Align the fan tray with the guides in the chassis and slide it gently into the slot
until its positioning pin touches the positioning hole in the chassis.
7 Insert screws on both sides of the fan tray.
CAUTION: Install a new fan tray soon after removing the old one to ensure that
the switch operates normally.
c
86
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
Upgrading the
Software
This section describes how to updated the software on the Switch 8800.
Required cables
■
■
■
Console cable (for serial interface)
One crossover and one standard network cables
Debug cable (for serial interface)
To upgrade the software:
1 Confirm that the host program is loaded before initiating the software upgrade.
2 Check the current version of the host and Boot ROM programs.
3 Back up the current host program, Boot ROM program, and configuration file (to
you PC) so that you can roll back a failed upgrade.
4 Load the host and Boot ROM program files to the switch. If the switch has two
fabrics, you can copy the host and Boot ROM program files to the standby fabric.
5 Upgrade the Boot ROM program on the fabric and I/O module (optional).
6 If the switch has two fabrics, specify the load programs for the active and standby
fabrics.
7 Reboot the switch.
8 Check that the board version is correct.
9 Load the software through command line interface (CLI) or the Boot menu. You
can load it through CLI using FTP or TFTP. You can load it locally from the Boot
menu using:
■
■
■
XModem and through Console port
TFTP and through Ethernet port
FTP and through Ethernet port
Each method is described below.
Upgrading Locally After powering on the switch, run the Boot ROM program. The terminal displays
through the Boot Menu the following information:
ZBB_TEST
Starting...
*************************************************
*
*
*
3Com Switch 8800 Family Bootrom, Version 109
*
*
*
*************************************************
Copyright(C) 2001-2005 by 3Com CORPORATION
Creation date: Dec 9 2003, 16:19:42
CPU type
CPU L2 Cache
: MPC755
: 1024KB
CPU Clock Speed : 400MHz
BUS Clock Speed : 100MHz
Memory Size
: 512MB
Flash file system init....done
Board type: Switch 8800 Family 3C17539
Upgrading the Software
87
Board self testing...........................
The board is steady
SlotNo of this board is 6
The MCX is exist
BootRom main system CRC check is OK
82559 register testing is OK
EPLD1 testing is OK
EPLD2 testing is OK
16c2552 register testing is OK
Please check LEDs......................LED testing finished
The switch Mac address is 00e0.fc00.1111
Press Ctrl+B to enter Boot Menu... 5
Password :
1 Press <Ctrl+B> as prompted to display the system Password : prompt.
To enter the Boot menu, you must press <Ctrl+B> within five seconds after the
appearance of the “Press Ctrl-B to enter Boot menu...” prompt. Otherwise, the
program decompression process begins. To access the Boot menu after the switch
enters the program decompression process, you need to restart the switch.
n
c
2 Enter the Boot ROM password (the switch’s default is no password). The Boot
menu displays as follows:
CAUTION: Make sure you have Boot ROM password.
MAIN MENU
1. Boot with default mode
2. Boot from Flash
3. Boot from HardDisk
4. Enter serial submenu
5. Enter ethernet submenu
6. Modify Flash description area
7. Modify bootrom password
0. Reboot
Enter your choice(0-7):
3 Ensure that the upgraded host program is compatible with the existing I/O
module’s Boot ROM program. Otherwise, you must upgrade it during a host
program upgrade.
4 When loading the host program through the Boot menu, configure the serial
not respond.
88
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
Figure 62 Hyper Terminal serial interface attribute settings
Upgrading software XModem is a file transfer protocol used for its simplicity and performance. It
through console port transmits files through serial interfaces, supporting 128 bytes and 1Kbytes in data
(XModem) units, checksum and CRC checking modes, and multiple transmissions attempts
(usually 10 attempts) when packet errors are found.
XModem completes the transmission by the receiving program (receiver) and the
sending program (sender). In XModem, the transmission begins by sending
negotiation characters from the receiver for the purpose of check mode
negotiation. After passing the negotiation, the sender is allowed to send the first
data packet. Upon receiving the complete packet, the receiver checks the packet
using the agreed upon check mode and sends an ACK if the packet has passed
the check and a NAK if it did not. After receiving the ACK, the sender sends the
next packet; if it receives a NAK, the sender retransmits the previously sent packet.
To run the Xmodem application:
1 In the Boot menu, type 4, press Enter, and the system accesses the serial interface
submenu as follows:
SERIAL SUBMENU
1. Download file to SDRAM through serial interface and boot
2. Download file to Flash through serial interface
3. Download file to HardDisk through serial interface
4. Modify serial interface boot parameter
0. Return to main menu
Enter your choice(0-4):4
Upgrading the Software
89
2 Type 4 in the serial interface submenu and press Enter to set the serial interface
download parameters from the following menu:
1: 9600(default)
2: 19200
3: 38400
4: 57600
5: 115200
please select an appropriate baudrate:
Enter your choice(1-5): 5
3 Select the download speed as needed. For example, enter 5 to select the
download speed of 115200 bps, then press Enter. The system displays the
following information:
BaudRate is 115200 bps. Please change the terminal’s speed to 115200
bps
4 Change the baud rate on the Console terminal to match your specification,
disconnect the terminal, connect it again, then press Enter. The terminal displays
the serial interface submenu again:
SERIAL SUBMENU
1. Download file to SDRAM through serial interface and boot
2. Download file to Flash through serial interface
3. Download file to HardDisk through serial interface
4. Modify serial interface boot parameter
0. Return to main menu
Enter your choice(0-4):2
■
■
After changing the baud rate, you must close the terminal emulation program
and start it again at least once in order to validate the new baud rate.
n
In Windows 98, you can disconnect and reconnect the terminal after changing
the baud rate. In Windows 2000, you must disconnect the terminal before
setting the baud rate and reconnect the terminal after it is complete.
5 Choose where you wish to store the downloaded file. For example, enter 2 to
download the file into the switch’s Flash memory then, press Enter. The system
displays the following information as it is downloading the file:
Please Select File .
XMODEM downloading ...CCC
6 Select [Transfer/Send File] in the terminal window. The Send File dialog box
7 Click Browse, and select the application, and change the protocol to XModem.
90
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
Figure 63 Send File dialog box
8 Click Send. The Xmodem dialog box displays.
9 After downloading the program successfully, the system begins to write the data
into the Flash memory. When the download is finished, the serial interface displays
the following submenu again.
XMODEM downloading ...CCC download successfully!
flash:/ s8500.app already exist,
delete it?(Y/N):y
Deleting file------------------------------------------------------
---------------------------------------------------------------Done
Free flash Space : 15862784 bytes
Writing flash------------------------------------------------------
-------------------------------------------------------Done
SERIAL SUBMENU
1. Download file to SDRAM through serial interface and boot
2. Download file to Flash through serial interface
3. Download file to HardDisk through serial interface
4. Modify serial interface boot parameter
0. Return to main menu
Enter your choice(0-4):
Upgrading the Software Trivial File Transfer Protocol (TFTP) transmissions are initiated by the client. When
Using TFTP downloading a file, the client sends a read request packet to the TFTP server,
receives the data packets from the server, and sends the ACK to the server. When
uploading a file, the client sends a write request packet to the TFTP server, then
sends the data packets to the server, and receives the ACK from the server. The
TFTP transmission files have two forms; binary for program transmission and ASCII
for text transmission.
To upgrade the software using TFTP perform the following steps.
This procedure uses a Switch 8814 work as the TFTP client.
n
1 Connect the switch to a PC where the file is located using the
management/upgrade Ethernet port. (You need the IP address of the PC. At the
same time, connect the switch to an external PC (that can be the same one that
contains the file) using the console port.
2 Run the TFTP server program on the PC connected to the management/upgrade
Ethernet port and specify the path for upgrading the application files.
3 Run the terminal emulation program on the PC connected to the console port,
and boot the switch to access the Boot menu.
Upgrading the Software
91
4 Enter 5 at Boot menu prompt and press Enter. The system displays the download
application program menu:
ETHERNET SUBMENU
1. Download file to SDRAM through ethernet interface and boot
2. Download file to Flash through ethernet interface
3. Download file to HardDisk through ethernet interface
4. Modify ethernet interface boot parameter
0. Return to main menu
Be sure to select 4 to modify boot parameter before downloading!
Enter your choice(0-4): 4
5 Enter 4 to select TFTP for upgrading the software and press Enter to set the
related TFTP parameters:
Note: Two protocols for download, tftp & ftp.
You can modify the flags following the menu.
tftp--0x80, ftp--0x0.
The message prompts you to set the flags to 0x80 when you download files using
TFTP and to 0x0 if you are using FTP.
n
’.’ = clear field; ’-’ = go to previous field; ^D = quit
boot device
processor number
host name
:fei0
:
: 8500 ,
: 8500.app
file name
inet on ethernet (e) : 1.1.1.1
inet on backplane (b):
host inet (h)
gateway inet (g)
user (u)
: 1.1.1.2
:
:
ftp password (pw) (blank = use rsh):
flags (f)
target name (tn)
:0x80
:
startup script (s) :
other (o)
:
Write flash...done!
6 After you provide the required information, the system accesses the Ethernet
interface submenu appears again:
ETHERNET SUBMENU
1. Download file to SDRAM through ethernet interface and boot
2. Download file to Flash through ethernet interface
3. Download file to HardDisk through ethernet interface
4. Modify ethernet interface boot parameter
0. Return to main menu
Enter your choice(0-4): 2
7 Specify where you wish to download the file (2 if you which to download the file
to Flash), press Enter. Upon successful completion, the system display the
following information:
Attached TCP/IP interface to fei0.
Attaching network interface lo0... done.
boot device
unit number
processor number
host name
: fei0
: 0
: 0
: 8500
: 8500.app
file name
92
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
inet on ethernet (e) : 1.1.1.1
host inet (h)
flags (f)
: 1.1.1.2
: 0x80
Prepare for loading....OK
Loading......done
flash:/s8500.app already exist,
delete it?(Y/N):y
Deleting file------------------------------------------------------
-------------------------------------------------Done
Free flash Space : 15862784 bytes
Writing Flash------------------------------------------------------
--------------------------------------------------------------------
--------------------------------------------------Done
8 The system accesses the Ethernet interface submenu again as shown below.
ETHERNET SUBMENU
1. Download file to SDRAM through ethernet interface and boot
2. Download file to Flash through ethernet interface
3. Download file to HardDisk through ethernet interface
4. Modify ethernet interface boot parameter
0. Return to main menu
Enter your choice(0-4):
Upgrading software The Switch 8800 Family applications can also be updated through the Ethernet
Using (FTP) port using FTP.
This procedure uses a Switch 8814 work as the FTP client.
n
1 Connect the switch to the PC containing the file using the management/upgrade
Ethernet port. (You need the IP address of the PC.) Connect the switch to an
external PC (that can be the same one that contains the file) through the console
port.
2 Run the FTP server on the PC connected to the management/upgrade Ethernet
port. Specify the path to the upgrade file and set the login username and
password.
3 Run the terminal emulation program on the PC connected to the Console port,
and boot the Switch to access the Boot menu.
4 See the corresponding steps (4 through 8) in the upgrading procedure using TFTP
above.
If you want to download files using FTP, please set the flags to 0x0 when setting
the Ethernet interface parameters.
n
5 After downloading the host program through the Boot menu, you must specify it
as the next boot program. In the following example, the host program is Switch
8800 Family-Comware 310-R1212.app.
MAIN MENU
1. Boot with default mode
2. Boot from Flash
3. Boot from CF card
4. Enter serial submenu
5. Enter ethernet submenu
6. Modify Flash description area
7. Modify bootrom password
Upgrading the Software
93
0. Reboot
Enter your choice(0-7):
Enter your choice(0-7): 6
Please input ’0’ or ’1’ (’0’:Boot from Flash, ’1’:Boot from CF card)
BootDev = 0
FlashFileName = Switch 8800 Family-Comware 310-R1212.app
Upgrading the Software If your terminal is connected to the switch over a network, you can load the Boot
Using the CLI ROM and host programs remotely through the CLI using FTP. or TFTP
Using FTP
1 Run the FTP server on a local PC, provided you have configured username and
password and have set the correct file directory. Specify the PC’s IP address (for
example, 10.10.110.1 in the example below).
2 Log on to the switch using Telnet or through the Console port to send host
program to the switch using FTP.
3 Using the Get command, download the main boot file (SWITCH002.app in the
example below), the active host program (SWITCH001.app in the example below),
and the Boot ROM program (SWITCHbtm.btm in the example below.
<3Com> 10.19.110.1
Trying ...
Press CTRL+K to abort
Connected.
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User(none):8500
331 Give me your password, please
Password:
230 Logged in successfully
[ftp] get SWITCH002.app SWITCH002.app
[ftp] get Switchbtm.btm Switchbtm.btm
[ftp] bye
If the switch has two fabrics, you also can copy the host and Boot ROM program
files to the standby Fabric.
n
4 Specify the next boot program. If the switch has two fabrics, specify the load
programs respectively for the active and standby fabrics (the current standby fabric
is in slot 7 in the example below).
a Load Boot ROM program
<3Com> boot bootrom flash:/Switchbtm.btm slot 6
<3Com> boot bootrom slot7#flash:/Switchbtm.btm slot 7
b Load host program
<3Com> boot boot-loader flash:/SWITCH002.app
<3Com>boot boot-loader slot7#flash:/SWITCH002.app
The URL form of the files in the standby fabric file system must start with
“slot[No.]#flash:/”, where [No.] is the standby fabric number.
n
<3Com> display boot-loader
The app to boot of board 6 at the next time is: flash:/SWITCH002.app
The app to boot of board 6 at this time is: flash:/SWITCH002.app
The app to boot of board 7 at the next time is: flash:/SWITCH002.app
The app to boot of board 7 at this time is: flash:/SWITCH002.app
<3Com> reboot
94
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
CAUTION:
c
■
You must reboot the switch using the reboot command to validate the host
program. If Flash memory space is not enough, you can delete some of the
program files in Flash after completing the Boot ROM loading. (3Com
recommends that you delete the host program that is no longer in use.) Then
upload the host program to the switch using FTP.
■
■
Make sure that you have saved other the configuration before rebooting.
Do not power the switch off during the loading process.
The Boot ROM and host program loading process is now complete.
Using TFTP
Using the CLI to upgrade using TFTP is similar to using FTP. The only difference is
that you use the tftp get command to download software to the switch. In this
case, the switch can only be used as a TFTP client to download the software to its
Flash memory from the TFTP server. Once the download is complete all remaining
steps are the same.
Upgrading the If you have the 360G Fabric (3C17508), download the application software image
Application Module files to the compact flash (CF) and then boot from the CF.
Program
If you have the 720G Fabric (3C17539), download the application software image
files directly to the Fabric’s onboard flash.
Troubleshooting the This section describes the problems may occur during the software upgrade.
Software Upgrade
No response from the fabric serial interface
Make sure the serial interface cable is in good condition and that its attributes are
set correctly.
Uploading the configuration file or host program using FTP fails
Check that the:
■
■
■
Configuration is correct and that the FTP server is started.
Flash has enough space for the target files.
TFTP flag is selected (TFTP is not supported).
The configuration did not save during the I/O module reboot
Before saving the configuration, you must check the operating status of the I/O
module. Do not save the configuration during the I/O module reboot. Otherwise,
the configuration you want to save may be lost.
I/O module program loading fails or you cannot register for a long period
■
■
■
■
Check that the I/O module type is supported on the current host program.
Check that the I/O module Boot ROM program matches the host program.
Check that the I/O modules are well seated.
Insert an I/O module to other slots to make sure it is not defective.
Password Loss
95
■
Check that the host program exists and that the current host program is
running.
Insufficient Flash memory
■
Empty the recycle bin when the I/O module starts.
Delete the unused files in the Flash.
■
Password Loss
If the switch’s Super password or Boot ROM password, contact your local support
representative.
96
CHAPTER 6: SWITCH MONITORING AND MAINTENANCE
LIGHTNING PROTECTION OF THE
SWITCH
A
Installing a Lightning
Arrester for the AC
Power
This appendix describes how to install the lightning arrester for the AC power (a
socket strip with lightning protection)
CAUTION: A lightning arrester is not shipped with the switch. You must purchase
it separately, if needed.
c
Make sure, when connecting an outdoor AC power cord directly to the switch,
that you connect a lightning arrester to the AC power (a socket strip with
lightning protection) before you plug the AC power cord into the switch. This
helps to prevent damage in the event of a lightning strike. Install your lightening
arrester according to its manufacturer’s instructions.
Figure 64 A Lightning Arrester
Grounding and polarity indicator (red) :
On means that the lines are incorrectly connected
(either the ground wire is not well connected, or the live and zero lines are incorrectly connected).
Check the power supply circuit.
Power switch
Normal operation indicator (green):
On means that the arrester is working. Otherwise, it
means that the protection circuit has been damaged.
Power socket (compliant with the IEC standard),
connected to the equipment room’s power supply
through power cord
Mainboard
Overload auto protector,
Multipurpose power socket connected to the device
which can be manually reset.
protected by the arrester
CAUTION:
c
■
Make sure that the arrester is well grounded before using the lightning arrester
for power.
■
After inserting the switch’s AC power cord plug into the lightening arrester’s
socket, if the green LED is on and the red LED does not alarm, it means that the
lightning arrester’s power is running and the lightning protection function is
active.
■
Make sure that the red LED is on. If there is a problem, determine if the
arrester’s ground wire is well grounded and the live and zero wires are
98
CHAPTER A: LIGHTNING PROTECTION OF THE SWITCH
connected in right direction. When the red LED is on, use a multimeter to
examine the polarity at the arrester’s power socket. If it is same as that of the
power socket in the equipment room, it means that the arrester is not well
grounded. If it is adverse to that of the power socket in the equipment room, it
means that the arrester’s power socket is set to the reverse polarity. In this case,
you should open the arrester’s power socket and correct the polarity. After
that, if the red LED still alarms, it means that the arrester is still not well
grounded.
Installing a Lightning
Arrester for the
Network Port
A network port lightning arrester is specifically designed for an 10/100M electrical
interface (an RJ-45 connector in this case) Ethernet port.
n
Make sure, when connecting an outdoor AC power cord directly to the switch,
that you connect a lightning arrester to the AC power (a socket strip with
lightning protection) before you plug the AC power cord into the switch. This
helps to prevent damage in the event of a lightning strike. Install your lightening
arrester according to its manufacturer’s instructions.
Required tools
■
■
■
Phillips screwdriver or flat-module screwdriver
Multimeter
Tilted wire cutter
Installation procedure
1 Remove the protection paper from one side of the double-faced adhesive tape,
and stick the tape to the surface of the arrester. Remove the protection paper from
the other side, and stick the arrester onto the switch’s chassis as close to the
grounding screw as possible.
2 Cut the arrester’s ground wire to the length of the distance between the arrester
and the switch’s grounding screw so that you can securely tighten the ground wire
to the switch’s grounding screw.
3 Use the multimeter determine if the arrester’s ground wire connects properly
chassis’s grounding screw.
4 According to the instructions provided with your network port arrester, connect
the arrester to switch using the cables (Make sure to insert the outdoor network
cable into the arrester‘s IN end, and the cable that is connected to the switch into
the arrester’s OUT end). Check that the arrester’s indicators display correctly.
5 Use the nylon ties to bundle the cables neatly.
Installing a Lightning Arrester for the Network Port
99
Figure 65 Installation diagram of a network port’s lightning arrester
Network cable indoors
Network cable from outdoors
Lightning arrester for the network port
(attached onto the chassis)
Switch
Lightning arrester ground wire
Power input
Switch grounding screw
Metal cabinet that contains the switch
Installation precautions
To ensure that the network port’s lightning arrester does not affect performance,
make sure that the lightning arrester for network port is:
■
Connected properly (see Step 4 in the previous section).
■
Well grounded. The ground wire for the arrester should be as short as possible.
Ensure that it is has proper contact with the switch’s grounding screw using the
multimeter.
■
Installed completely. If the switch has more than one network ports to
interconnect with other devices using outdoor cables, you should install
lightning arresters for all network ports for protection.
100
CHAPTER A: LIGHTNING PROTECTION OF THE SWITCH
3COM NETWORK MANAGEMENT
B
3Com has a range of network management applications to address
networks of all sizes and complexity, from small and medium businesses
■
■
■
■
■
3Com Network Director
3Com Network Access Manager
3Com Enterprise Management Suite
Integration Kit with HP OpenView Network Node Manager
Details of these and other 3Com Network Management Solutions can be
found at www.3com.com/network_management
3Com Network
Supervisor
3Com® Network Supervisor (3NS) is an easy-to-use management
application that graphically discovers, maps, and monitors the network
and links. It maps devices and connections so you can easily:
■
■
■
■
■
Monitor stress levels
Set thresholds and alerts
View network events
Generate reports in user-defined formats
Launch embedded device configuration tools
3NS is configured with intelligent defaults and the ability to detect
network misconfigurations. It can also offer optimization suggestions,
making this application ideal for network managers with all levels of
experience.
To find out more about 3Com Network Supervisor and to download a
trial version, go to: www.3com.com/3ns
102
APPENDIX B: 3COM NETWORK MANAGEMENT
3Com Network
Director
3Com Network Director (3ND) is a standalone application that allows you
to carry out key management and administrative tasks on midsized
networks. By using 3ND you can discover, map, and monitor all your
3Com devices on the network. It simplifies tasks such as backup and
restore for 3Com device configurations as well as firmware and agent
upgrades. 3ND makes it easy to roll out network-wide configuration
changes with its intelligent VLAN configuration tools and the powerful
template based configuration tools. Detailed statistical monitoring and
historical reporting give you visibility into how your network is
performing.
To find out more about how 3Com Network Director can help you
manage your 3Com network and to download a trial version, go to:
www.3com.com/3nd
3Com Network
Access Manager
3Com Network Access Manager is installed seamlessly into Microsoft
Active Directory and Internet Authentication Service (IAS). It simplifies the
task of securing the network perimeter by allowing the administrator to
easily control network access directly from the “Users and Computers”
console in Microsoft Active Directory. With a single click, a user (or even
an entire department) can be moved to a different VLAN, or a computer
can be blocked from connecting to the network.
3Com Network Access Manager leverages the advanced desktop security
capabilities of 3Com switches and wireless access points (using IEEE
802.1X or RADA desktop authentication) to control both user and
computer access to the network.
To find out more about 3Com Network Access Manager, go to:
www.3com.com/NAM
3Com Enterprise Management Suite 103
3Com Enterprise
Management Suite
3Com Enterprise Management Suite (EMS) delivers comprehensive
management that is flexible and scalable enough to meet the needs of
the largest enterprises and advanced networks.
This solution provides particularly powerful configuration and change
control functionalities, including the capability to:
■
■
■
Customize scheduled bulk operations
Create a detailed audit trail of all network changes
Support multiple distributed IT users with varying access levels and
individualized network resource control
The client-server offering operates on Windows and UNIX (Linux and
Solaris) systems.
3Com EMS is available in four packages, varying in the maximum number
of devices actively managed. These include SNMP-capable devices such as
switches, routers, security switches, the 3Com VCX™ IP Telephony server,
and wireless access points:
■
■
■
■
Up to 250 devices
Up to 1,000 devices
Up to 5,000 devices
An unlimited number of devices
To find out more about 3Com Enterprise Management Suite, go to:
www.3com.com/ems
Integration Kit with
HP OpenView
Network Node
Manager
3Com Integration Kit for HP OpenView Network Node Manager offers
businesses the option of managing their 3Com network directly from HP
OpenView Network Node Manager. The kit includes Object IDs, icons,
MIBs, and traps for 3Com devices. The package supports both Windows
platforms and UNIX or Solaris platforms. It can be installed as a
standalone plug-in to HP OpenView, or used with a 3Com management
application such as 3Com Enterprise Management Suite (EMS).
To find out more about 3Com Integration Kit for HP OpenView Network
Node Manager, go to: www.3com.com/hpovintkit
104
APPENDIX B: 3COM NETWORK MANAGEMENT
|