York Stellar 2000 H Da012 User Manual

036-21105-004 Rev. A (0902)  
DESCRIPTION  
®
The HDA Series condensing unit is the outdoor part of a ver-  
satile system of air conditioning. It is designed to be custom-  
matched with one of UPG's complete line of evaporator sec-  
tions, each designed to serve a specific function. Matching  
Air Handlers are available for upflow, downflow or horizontal  
application to provide a complete system. Electric heaters are  
available if required.  
TECHNICAL GUIDE  
STELLAR 2000  
FEATURES  
QUALITY CONDENSER COILS - The coil is constructed  
of enhanced copper tube and aluminum fins.  
COIL PROTECTION - Coils are protected from damage by  
a polymer mesh applied between the coil face, and a PVC  
coated steel coil guard.  
SPLIT-SYSTEM AIR CONDITIONERS  
10 SEER 50 HZ  
PROTECTED COMPRESSOR - The compressor is inter-  
nally protected against high pressure and temperature.  
This is accomplished by the simultaneous operation of  
high pressure relief valve and a temperature sensor which  
protect the compressor if undesirable operating conditions  
occur.  
MODELS: H*DA012 THRU H*DA076  
(1 & 3 PHASE)  
(1 THRU 7.5 NOMINAL TONS)  
DURABLE FINISH - Cabinet is made of pre-painted steel.  
The pre-treated flat galvanized steel provides a better  
paint to steel bond, which resists corrosion and rust creep.  
Special primer formulas and glossy earth tone finish insure  
less fading when exposed to sunlight.  
LOWER INSTALLED COST - Installation time and costs  
are reduced by easy power and control wiring connec-  
tions. Discharge line heat exchanger knockouts are pro-  
vided, if required. Both quick connect and sweat connect  
models are available. Both service valves are firmly affixed  
to the unit. The sweat unit contains enough refrigerant for  
matching indoor coils and 15 feet of interconnecting pip-  
ing. The small base dimension means less space is  
required on the ground or roof.  
TOP DISCHARGE - The warm air from the top mounted  
fan is blown up away from the structure and any landscap-  
ing. This allows compact location on multi-unit applica-  
tions.  
LOW OPERATING SOUND LEVEL - The upward air flow  
carries the normal operating noise up away from the living  
area. The rigid top panel effectively isolates any motor  
sound. Isolator mounted compressor and the rippled fins  
of the condenser coil muffle the normal fan motor and  
compressor operating sounds.  
LOW MAINTENANCE - Long life permanently lubricated  
motor- bearings need no annual servicing.  
EASY SERVICE ACCESS - Fully exposed refrigerant con-  
nections and a single panel covering the electrical controls  
make servicing easy.  
Due to continuous product improvement, specifica-  
tions are subject to change without notice.  
up-to-date technical information.  
SECURED SERVICE VALVES - Secured re-usable ser-  
vice valves are provided on both the liquid and vapor  
sweat connections for ease of evacuating and charging.  
FACTORY TESTED - to verify system operation and con-  
trol functioning before shipment.  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
036-21105-004 Rev. A (0902)  
COOLING PERFORMANCE  
AIR TEMP ON CONDENSER  
95°F 115°F  
MBH  
SUCT.T/P @ COMPR.  
MODEL  
75 °F  
125°F  
TEMP  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
35  
40  
45  
50  
PSIG  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
61.5  
68.5  
76.0  
84.0  
MBH  
13.0  
14.5  
16.1  
17.7  
18.7  
20.8  
22.9  
25.2  
21.9  
24.3  
26.7  
29.3  
27.6  
30.4  
33.3  
36.3  
33.6  
37.3  
40.9  
44.8  
46.7  
51.7  
56.8  
62  
KW  
1.31  
1.36  
1.41  
1.44  
1.83  
1.90  
1.97  
2.05  
2.34  
2.41  
2.47  
2.53  
2.64  
2.71  
2.78  
2.85  
3.07  
3.09  
3.23  
3.37  
3.87  
4.07  
4.28  
4.49  
5.16  
5.33  
5.51  
5.71  
5.55  
5.69  
5.84  
5.99  
MBH  
10.9  
12.3  
13.7  
15.2  
15.6  
17.6  
19.6  
21.8  
18.7  
20.9  
23.2  
25.6  
23.9  
26.5  
29.2  
31.9  
28.8  
32.1  
35.2  
39.1  
39.1  
43.5  
48  
KW  
1.41  
1.49  
1.54  
1.58  
1.99  
2.07  
2.17  
2.27  
2.54  
2.63  
2.73  
2.82  
2.88  
2.99  
3.08  
3.18  
3.43  
3.48  
3.69  
3.85  
4.82  
5.08  
5.34  
5.6  
KW  
1.53  
1.62  
1.69  
1.74  
2.09  
2.20  
2.31  
2.43  
2.71  
2.84  
2.97  
3.10  
3.11  
3.24  
3.37  
3.49  
3.82  
3.88  
4.13  
4.35  
57.8  
6.14  
6.51  
6.89  
7.25  
7.41  
7.58  
7.76  
7.98  
8.14  
8.30  
8.48  
MBH  
8.0  
9.1  
KW  
1.59  
1.69  
1.76  
1.82  
2.13  
2.24  
2.37  
2.49  
2.77  
2.91  
3.06  
3.20  
3.20  
3.34  
3.48  
3.62  
4.01  
4.08  
4.36  
4.60  
6.39  
6.83  
7.28  
7.73  
7.92  
8.08  
8.25  
8.43  
8.82  
8.98  
9.15  
9.32  
9.0  
10.2  
11.3  
12.4  
12.5  
14.3  
16.2  
18.3  
15.6  
17.6  
19.7  
21.9  
20.2  
22.5  
25.0  
27.5  
24.0  
26.9  
30.2  
33.3  
31.9  
35.7  
39.6  
43.7  
43.4  
47.5  
51.8  
56.1  
58.3  
64.3  
70.5  
76.9  
H3DA012  
H3DA018  
H3DA024  
H3DA030  
H3DA036  
H3DA048  
H3DA060  
10.1  
11.1  
10.9  
12.6  
14.5  
16.5  
14.0  
15.9  
18.0  
20.0  
18.3  
20.5  
22.8  
25.5  
21.6  
24.3  
27.5  
30.4  
28.3  
31.8  
35.4  
39.2  
40.8  
44.7  
48.7  
52.9  
54.4  
60.2  
66.2  
72.4  
52.7  
48.7  
53.1  
57.8  
62.5  
66.2  
72.5  
79.1  
86.1  
53.8  
58.9  
64.1  
69.6  
73.9  
80.7  
87.7  
95.1  
6.09  
6.25  
6.43  
6.61  
6.60  
6.75  
6.91  
7.07  
H3DA076  
NOTES:  
1. For condensing unit only. Does not include effect of evaporator motor power or heat.  
2. Performance based on 1superheat and 1sub-cooling at condensing unit.  
a. Increase capacity 1% for each increase in sub-cooling.  
b. Decrease capacity 1% for each decrease in sub-cooling.  
3. Sub-cooling in excess of 2may result in excessively high condensing temperature with air on condenser above 115°F.  
Maximum recommended condensing temperature is 140°F.  
ACCESSORIES  
SOUND RATINGS  
Refer to Price Manual for specific model numbers.  
Off Cycle Timer - Provides a 5 minute off cycle to prevent  
rapid recycling of the compressor.  
Room Thermostats - A wide selection of matching thermo-  
stats is available to provide features required for any installa-  
tion.  
Start Assist Kit - Provides increased starting torque for  
areas with low voltage conditions.  
Compressor Blanket - Designed to further reduce the nor-  
mal operating sounds of H3DA units.  
H*DA  
MODEL  
SOUND RATING  
DECIBELS  
H3DA012  
H3DA018  
H3DA024  
H3DA030  
H3DA036  
H3DA048  
H3DA060  
H3DA076  
7.8  
7.8  
7.8  
7.8  
7.8  
8.0  
8.2  
8.2  
Unitary Products Group  
3
036-21105-004 Rev. A (0902)  
COOLING CAPACITY  
AIR HANDLER  
COOLING  
NET MBH  
COIL MODEL  
RATED  
CFM  
UNIT MODEL  
MODEL  
SEER  
(EER)  
ELECTRIC HEAT KW  
W
KW  
TOTAL  
SENS.  
1 & 3 PHASE HDA WITH N1AH AIR HANDLER & G2FD COILS  
H3DA018S78  
N1AHB12  
N1AHB12  
N1AHB12  
2,5,7.5,10  
17  
G2FD024S17  
G2FD024S17  
G2FD030S17  
G2FD030S17  
G2FD036S17  
G2FD036S17  
G2FD046S17  
G2FD048S21  
G2FD048S24  
G2FD060S24  
G2FD060S24  
650  
800  
20.4  
23.5  
24.0  
30.0  
30.2  
34.2  
-
14.9  
17.1  
17.5  
21.9  
22.0  
24.9  
-
2.23  
3.07  
2.79  
3.32  
3.35  
4.05  
-
9.60  
8.90  
9.00  
9.70  
9.70  
9.00  
-
H3DA024S78  
2,5,7.5,10  
17  
800  
5,7.5,10,15,18  
-
17  
17  
17  
21  
21  
24  
24  
24  
1025  
1025  
1200  
1200  
1550  
1550  
1550  
1800  
H3DA0308S78  
H3DA036S50  
N1AHB12  
N1AHB12  
5,7.5,10,15,18  
N1AHC16  
N1AHD20  
N1AHD20  
N1AHD20  
5,7.5,10,15,20  
7.5,10,15,20,25,30  
7.5,10,15,20,25,30  
7.5,10,15,20,25,30  
46.2  
46.2  
47.8  
60.0  
34.7  
34.7  
35.9  
43.9  
5.06  
5.06  
5.16  
6.45  
9.90  
9.90  
9.90  
9.40  
H3DA048S50  
H3DA060S50  
1 & 3 PHASE HDA WITH F2RP SINGLE PIECE AIR HANDLERS  
H3DA018S78  
H3DA024S78  
H3DA030S78  
H3DA036S50  
H3DA048S50  
H3DA060S50  
2,5,7.5,10  
2,5,7.5,10  
18  
18  
-
-
-
-
-
-
650  
850  
16.9  
21.0  
28.0  
35.3  
42.9  
54.1  
12.5  
15.5  
20.8  
23.8  
31.7  
24.5  
2.0  
2.5  
3.2  
4.2  
5.3  
6.4  
-
F2RP024  
F2RP024  
F2RP036  
F2RP036  
F2RP048  
F2RP060  
-
5,7.5,10,15,19  
5,7.5,10,15,19  
10,15,20,25  
10,15,20,25  
21.5  
21.5  
24  
1090  
1090  
1490  
1735  
-
8.5  
8.2  
8.4  
24  
3 PHASE HDA WITH COMMERCIAL BELT DRIVE K*EU EVAPORATOR BLOWER UNIT  
H3DA060S50  
H3DA076S50  
K2EU060  
K5EU090  
10,16,25  
36  
52  
-
-
2000  
2550  
55.5  
74.6  
39.5  
53.7  
6.30  
7.61  
10.00  
9.80  
10,16,26,36  
MBH based on 80°F entering air temperature, 50% RH, and rated air flow.  
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.  
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided  
by the total electric power input inwatt-hours during the same period.  
(EER) = Energy Efficiency Ratio-steady state total BTUH/electric power input.  
4
Unitary Products Group  
036-21105-004 Rev. A (0902)  
TYPICAL FIELD WIRING  
POWER  
WIRING  
CONTROL  
WIRING  
GROUND  
LUG  
LOW VOLTAGE  
JUNCTION BOX  
ALL OUTDOOR WIRING MUST BE WEATHERPROOF.  
USE COPPER CONDUCTORS ONLY.  
TYPICAL FIELD WIRING - 1 PHASE  
POWER WIRING  
CONTROL WIRING  
FACTORY WIRING  
POWER WIRING  
24 VOLT CONTROL WIRING  
MINIMUM 18GA. WIRE  
(NEC CLASS 2)  
230-1-50  
FURNACE OR AIR HANDLER TERMINAL BLOCK  
Y R G W  
C
*
TERMINAL W IS  
ONLY REQUIRED  
ON SYSTEMS  
WITH HEAT.  
CONTACTOR  
TERMINALS  
GND.  
LUG  
*
COIL  
Y
R
G
W
ROOM THERMOSTAT  
CONDENSING UNIT  
TYPICAL FIELD WIRING - 3 PHASE  
POWER WIRING  
380/415-3-50  
POWER WIRING  
CONTROL WIRING  
FACTORY WIRING  
24 VOLT CONTROL WIRING  
MINIMUM 18GA. WIRE  
(NEC CLASS 2)  
FURNACE OR AIR HANDLER TERMINAL BLOCK  
C
Y R G W  
TERMINAL W IS  
ONLY REQUIRED  
ON SYSTEMS  
WITH HEAT.  
*
CONTACTOR  
TERMINALS  
GND.  
LUG  
*
COIL  
Y
R
G
W
ROOM THERMOSTAT  
CONDENSING UNIT  
Unitary Products Group  
5
036-21105-004 Rev. A (0902)  
TYPICAL INSTALLATION  
THERMOSTAT  
WEATHERPROOF  
DISCONNECT  
SWITCH  
TO  
POWER  
SUPPLY  
48” OVERHEAD  
CLEARANCE  
TO  
INDOOR  
BLOWER  
NEC  
CLASS 1  
WIRING  
12” REAR AND  
SIDES  
NEC  
CLASS 2  
WIRING  
TO COIL  
24” SERVICE ACCESS  
CLEARANCE  
NOTE: All outdoor wiring must be weatherproof  
Seal opening(s) with permagum  
or equivalent  
MATCHING INDOOR COMPONENTS  
ADD-ON COILS - FOR FURNACE APPLICATIONS  
G2FD*  
MULTI-POSITION  
(UPFLOW, HORIZONTAL  
AND DOWNFLOW)  
AIR HANDLERS - FOR NON-FURNACE APPLICATIONS  
N1AH  
MODULAR BLOWER  
(UPFLOW, HORIZONTAL  
AND DOWNFLOW)  
K*EU060,090  
LIGHT COMMERCIAL  
APPLICATIONS  
F2RP  
FAN COIL UNITS  
(UPFLOW, HORIZONTAL)  
G2FD  
COIL  
6
Unitary Products Group  
036-21105-004 Rev. A (0902)  
NOTES  
Unitary Products Group  
7
Subject to change without notice. Printed in U.S.A.  
036-21105-004 Rev. A (0902)  
Copyright © by York International Corp. 2002. All rights reserved.  
Supersedes: 036-21105-003 Rev. C (0901)  
Unitary  
Product  
Group  
5005  
York  
Drive  
Norman  
OK  
73069  

Lifebreath 1200ddpool User Manual
Ohlins 07235 01a5lP65 User Manual
Panasonic Hybrid Ip Pbx Kx Tda200 User Manual
Remote Technologies Bdsv3 User Manual
Ricoh Aficio Mp C1500 User Manual
Royal Sovereign Arp 1200dm User Manual
Sharp Al 2040cs User Manual
Source Technologies 1352 Micr 40 User Manual
Toshiba Air Conditioner Ceiling Type User Manual
Toshiba EStudio E Studio 523 User Manual