Xerox All In One Printer User Manual

Product Safety Data Sheet  
XEROX  
Product:  
DocuColor 70  
PSDS No.:  
0907  
ISSUE DATE: 02/16/98  
REV. DATE: 04/29/03  
Section I - Product Identification  
Manufacturer's Name  
Emergency No. EH&S Inquiries  
Xerox Corporation  
(585) 422-2177 (800) 828-6571  
Manufacturer's Address  
Rochester, New York 14644  
Product Designation  
Product Identifier:  
DocuColor 70  
DCP-1-60  
Section II - Electrical Information  
Line Voltage  
(Volts)  
208-240 V, 3 phase  
3 wire, delta  
Line Current  
Freq.  
(Hertz)  
60  
50/60  
50/60  
50/60  
50/60  
50/60  
Branch Cir. Protection  
(Amps)  
(Amps)  
35A - DCP-1-60  
10A - Console  
0.5A - Exhaust  
7A -TWR htr  
15A - GEM  
1.2A -Stacker  
Line Cord/Plug Specification  
Power Consumption (Watts)*  
Hard Wired  
Printer -  
Cooling Unit - 1,500  
GEM - 3,500  
10,000  
Agency Approvals  
UL  
File Number E160792  
CSA (cUL) File Number E160792  
Section III - Supplies  
Xerox Part No.  
Material Safety Data Sheet  
Black Dry Ink  
Cyan Dry Ink  
Yellow Dry Ink  
Magenta Dry Ink  
Black Developer  
Cyan Developer  
Yellow Developer  
Magenta Developer  
6R895  
6R896  
6R897  
6R898  
5R601  
5R602  
5R603  
5R604  
A-0608  
A-0609  
A-0610  
A-0611  
B-0307  
B-0308  
B-0309  
B-0310  
Section IV - Environmental Information (Configuration: w/o Sorter and ADF)  
Heat Emission*  
Environmental Limitations  
(BTU/HR)  
Printer:  
Cooling Unit: 5,119  
Min  
15  
10  
Max  
85  
32  
34,129  
Relative Humidity (%):  
Ambient Temp. (oC):  
GEM:  
11,945  
* Based on a five minute average  
www.xerox.com Reference "About Xerox"  
Product: DocuColor 70  
PSDS No.: 0907  
Section V - Emission/Exposure Information**  
Light Source  
LED  
Electromagnetic Emissions  
US  
Canada  
FCC: Class A  
DOC: Class A  
Audible Noise  
Run  
Standby  
TLV  
85.0 dB(A)  
<72 dB(A)  
<65 dB(A)  
Ozone  
Concentration Based on Simulation Model:  
Daily Copy Volume  
Room Size  
20,450 copies  
250 m3  
1/2 Air Room Change per Hour  
Ozone filter replacement at 900,000 copies.  
1,720 ug/min  
TLV  
0.017 ppm (TWA)  
0.1 ppm  
Total Dust  
TLV  
0.022 mg/m3  
10 mg/m3  
Toner  
<1.5 ug/m3  
Organics  
< 1 ppb individual, <47 ppb Toluene equiv. by Tenax GC/MS  
Section VI - Product Recycling and Disposal  
Xerox operates a worldwide equipment takeback and reuse/recycle program. Contact your Xerox  
sales representative (1-800-ASK-XEROX) to determine whether this Xerox product is part of the  
"About Xerox" section). If your product is not part of the Xerox program and you are managing its  
disposal, please note that the product may contain lead, mercury and other materials whose disposal  
may be regulated due to environmental considerations. For recycling and disposal information,  
contact your local authorities. In the United States, you may also refer to the Electronic Industries  
* Based on a five minute average  
** TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference  
of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are  
considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a  
normal eight hour workday.  
All measurements were made on products performing within established operating specifications and received recommended  
maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.  
www.xerox.com Reference "About Xerox"  

Minolta Bizhub C352 User Manual
Samsung Aw25ecb User Manual
Sanyo Eco I 07ahx52 User Manual
Soleus Air Ky 320 User Manual
Sunbeam 2585 User Manual
Toshiba 6520c User Manual
Trion Air Boss Dc 4m User Manual
Whirlpool Acq082xk1 User Manual
White Rodgers 2sd1 User Manual
York Tcgd12 Thru 60 User Manual