ONE YEAR LIMITED WARRANTY &
FIVE YEAR WARRANTY ON COMPRESSOR
ThisWHYNTER SNO portable air conditioner is warranted, to the original owner within
the 48 continental states, for one year from the date of purchase against defects in material
and workmanship under normal use and service. Should your SNO portable air conditioner
prove defective within one year from the date of purchase, return the defective part or unit,
freight prepaid (within two months of purchase;after two months to one year, customer will
be responsible for freight cost toWhynter’s service department), along with an explanation.
Please ship the SNO portable air conditioner in its original packaging material to avoid damage
in transit. Please retain original box and packaging material. Under this warranty,Whynter
will repair or replace any parts found defective.This warranty is not transferable.After the
expiration of the warranty,the cost of labor and parts will be the responsibility of the original
owner of the unit.
Owner’s Manual
For models ARC-12D & ARC-12H
THISWARRANTY DOES NOT COVER:
-Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
- Damage, accidental or other wise, to the portable air conditioner while in the possession
of a consumer not caused by a defect in material or workmanship;
- Damage caused by consumer misuse, tampering, or failure to follow the care and special
handling provisions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
1) Filter.
2) Damage caused by repairs or alterations of the unit by anyone other than authorized
by the manufacturer.
3) Freight and Insurance cost for the warranty service.
To obtain service or information, contact
Whynter Innovations Group via Email at [email protected] or call
866-WHYNTER.
It is important that you read
these instructions before
using your new purchase and
we strongly recommend that
you keep them in a safe place
for future reference.
14
Maintenance
Before Use
Always unplug the unit from the wall outlet before beginning
the cleaning.
Important!
• Transport the unit in an upright position only, or leave it in an upright position
for at least 2 hours before first use.
Cleaning the Housing
Use a soft, damp cloth to wipe the body clean.
• Always place the unit on an even surface (Figure 1).
• The power cord is UL listed. It has a built-in
L.C.D.I. (Leakage, Current, Detection, Interruption)
circuit breaker for added safety.
Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other
cleaning solutions.These could possibly damage the cabinet.
Figure 1
If the power supply is interrupted, press the reset
button to reconnect the unit to the power source.
Cleaning the Filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then
rinse them thoroughly under running water (no hotter than 104°F).
Dry thoroughly before replacing.
• Make sure the unit is connected to a correctly grounded power supply
(refer to the rating label located at the back of the unit).
Do not wet the activated carbon filter, remove from frame before rinsing.
• An opening in a window or wall is required to accommodate
the exhaust hose (kit supplied) to expel the warm air.
IMPORTANT! Never operate the unit without the filters.
• Do not cover or obstruct the appliance inlet or outlet grilles (Figure 2).
End of Season Storage
Unplug the unit.
• To avoid the risk of shock, the product should never be used
in bathrooms, shower rooms or in any other steamy or wet areas.
Drain the condensed water COMPLETELY (please refer to page 9).
Clean or change the filter.
• The unit will cool when the room temperature is between
64°F and 110°F depending on the thermostat setting.
On a warm day, turn the unit to fan mode for a couple of hours so that the
inside can dry out completely.
Figure 2
• Do not sit or place objects on the unit.
It is recommended that the unit be put back into its original carton for storage.
Do not stack heavy objects on top of the unit.
• Do not touch the unit with wet/damp hands or when standing barefoot.
• Avoid all contact with chemical based materials.
• The filter must be used with the product at all times.
StoringThe Power Cord
When the unit is not in use, please store the power cord away as shown in Figure 3.
When removing for cleaning, always disconnect the unit from the mains first.
• Turn off the appliance when not in use.
• At the end of each season all water must be drained and the unit and filters cleaned before storage.
• Drainage of the water container is required before moving the unit or
putting it into storage.
• If the electric socket is different from the plug provided, have a professionally qualified electrician
replace the plug with a suitable one. Avoid the use of adaptor plugs, multiple sockets and/or extension
leads; if their use is necessary, ensure that they conform to the current safety regulations.
• Do not pull the supply cable or place it near a source of heat; always unroll it completely
to avoid the possibility of dangerous overheating.
Figure 3
• If the supply cord is damaged, it must be replaced by the service agent or a similarly qualified person.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IFTHE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED.
10
3
Installation
Operation
Setting The Fan Speed
Press the SPEED button to choose the fan speed you require, high or low. The indicator of high
or low fan will light up at the same time.
If the unit is in AUTO mode, it will select the fan speed automatically according to the
ambient temperature (the related indicators, cool, fan or heat will light up), at this time the
fan speed switch is invalid.
Setting theTimer
Press theTIMER button to set the operating hours you desire (1 to 12 hours, the timer
indicator will light up). When the set time has elapsed, the machine will turn off
automatically. The display window will show the hour(s) you set as you press theTIMER button.
If the timer button is not pressed, the unit will work continuously.
By pressing the timer button but without turning on the unit, you can PRE-SET the time for
the machine to work. For example, if you press the timer to ‘2’, the unit will come on
automatically after 2 hours.
Window Kit Installation
In order for this unit to function
properly, it must be vented to the
outside.
2.Attach Slide Bar Connector,
(Round Connector) to the
other end of the Hose by
extending hose at least 6".
Then tighten Hose by turing
the (Round Connector)
clockwise.
3. Place Adjustable Slide Bar in
the wondow and expand so it
fits tightly.
All the above functions can also be performed with the supplied remote
control. This remote control requires 2 AAA batteries to operate.
Fitting the Exhaust Hose through
the window is easy. Please see
below.
4. Lower the windwo.
Regulating the airflow direction
5. Make sure the Hose has no
kinks.
1. Extend Hose at least 6" and
insert it into back of the unit,
tightening into place by turning
it clockwise.
Slide Bar has 3 sections which
allows installation in windows up
to 48" in width.
Turn the roller on the air vent to control
the airflow direction from the vertical louvres.
IMPORTANT!
• The compressor will start approximately 3 minutes after the unit is turned on (this will
help prolong the life of the compressor). After switching the unit off, please wait at least
3 minutes before turning the unit back on.
• The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps
working at the set level. If the ambient temperature rises above the chosen temperature +/-5°F,
the cooling will resume.
Wall Connection
1. Make a hole (5.1" in diameter)
in the wall.
• In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set
(the fan keeps working at the set level). When the room temperature drops 5°F below the chosen
temperature, heating will resume.
3. Extend one end of the exhaust
pipe (part #11) and screw into
the Round Connector by
turning clockwise.
5. Push Adaptor to fit firmly
over the opening on the back
of the unit.
2. Insert the Round Connector
(part #14) into the hole and
hold in place by using 4 small
screws (not supplied).
• This machine is equipped with an ANTI-FROST function. Sometimes, while using the heating function
during low temperatures, the heating will stop for a while to melt the internal frost. When this occurs,
wait for heating to resume.
**When not in use, cover the
Round Connector and hole
with Cap (part #15).
4. Extend other end of exhaust
pipe and screw inAdaptor (part
#10) by turning clockwise.
• As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.
8
5
Operation
Installation
Control Panel
Mounting the exhaust pipe
9. Timer operation indicator
10. Compressor Indicator
11. Temperature up selector
12. Temperature down selector
13. Fan speed selector
1. Set temperature indicator
2. Room temperature indicato
3. Low fan speed indicator
4. High fan speed indicator
5. Automatic mode indicator
6. Cooling mode indicator
7. Fan mode indicator
• The supplied exhaust hose can be
extended from 1 foot to 5 feet
for mounting. It is recommended that
you use the shortest possible length of hose.
14. Mode (function)
option selector
• Take care to prevent any kink or
bend in the middle of the exhaust
hose, as this will trap hot exhaust air,
which will radiate back into the room.
15. Timer selector
8. Heating mode indicator
16. ON/OFF (power) selector
17. Display window
(for models with heating options)
Setting Mode/Function
Press the MODE button to select the required working mode:Automatic, Cooling, Fan or Heating (Heating is only
available for ARC-12H).The green indicator illustrating your selected mode lights up. It is recommended to select
Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please
see below) that cannot be changed.
The indicators of the functions in progress come on at the same time,e.g.Cool and Lo = Cooling mode with Low fan speed.
Auto Mode
When this mode is selected, the unit is preset to the following temperature settings and unit will only start to:
• Cool when room temperature is higher than 75ºF
• Heat when room temperature is lower than 68ºF (ARC-12H only)
If room temperature is between 68ºF and 75ºF, unit will stay in Fan mode. Again, when inAuto Mode, the temperature
settings cannot be changed.
WARNING!
The length of the exhaust pipe is specially
designed according to the specification of
this product.
Do not replace or extend it with your own hose
as this could cause the unit to malfunction.
Setting theTemperature in Cooling or Heating Mode
The display window’s default is to display the ambient room temperature. The green indicator light under RT is on.
(RT = RoomTemperature)
To set your desired temperature, press theTemperature up or down buttons (ranging from 62ºF to 90ºF). Each
press will increase or decrease your set temperature by 1ºF. When pressing the temperature up or down buttons,
the window will change to display your set temperature.At this time, the green indicator will light under ST (Set
Temperature). Once the temperature up or down buttons is released, the window will return to displaying the
ambient temperature after a second.
Note: When unit is in the following modes: Auto, Cool, or Heat - the compressor will cool/heat the room to
reach the set temperature. Once the ambient temperature has reached the set temperature, the compressor will
stop and unit will run in Fan mode. To conserve energy, the compressor will not start immediately after a couple
degrees increase or decrease, but will wait for a 5ºF allowance. For example:
Installation of the Carbon Filter
1. Remove the filter frame from the unit by
pressing down on tabs and pulling forward.
2. Separate the filter from the filter frame.
3. Remove the active carbon filter
from its plastic bag.
4. Insert the active carbon filter
into the filter frame.
5. Fix the filter by reassembling
the fixer onto the filter frame.
2
3
4
5
In Cooling Mode with a set temperature of 70ºF
When compressor first stops after reaching 70ºF, unit will auto-switch to Fan.
Compressor will start cooling again when ambient temperature increases to 75ºF or above.
In Heating Mode with a set temperature of 72ºF
When compressor first stops after reaching 72ºF, unit will auto-switch to Fan.
Compressor will start heating again when ambient temperature drops to 67ºF or below.
6. Re-fit the filter frame
inside the unit.
7. It is recommended to
replace the carbon filter
every 3 to 6 months.
In Auto Mode (with preset temperature of 68ºF for heat and 75ºF for cool)
Compressor will start cooling again when ambient temperature reaches above 80ºF or will start heating when
ambient temperature drops below 63ºF.
7
6
Parts
Drainage
During the process of cooling, some water will be extracted from the air into the unit. Most of this water
is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air
Conditioners. If the unit is operated inVERY HUMID air, water will collect in the container inside the unit.
If the water container is full, the compressor will stop, but the fan will continue to circulate the air. The
POWER indicator will blink to inform you to empty the internal container. To make the cooling function
work again, please empty the water by one of the following methods:
Front
Back
By the Draining into a Container
Use a Shallow Container or Dish
1. Turn off the unit.
2. Position a flat container or dish under the drain hole.
Do not allow the water to drip continuously into the container,
as it might easily overflow.
3. Remove the drain knob & rubber plug from the drain hole.
The condensed water will drain out automatically.
1. Control Panel
2. Cooling Air Outlet
3. Handle
5. Air Inlet
4. When the container is almost full, replace the rubber plug
into the drain hole to stop the water. Empty the container.
6. Air Filter
5. Repeat steps 2, 3 & 4 until all the condensed water is emptied.
7. Exhaust Air Outlet
8. Cord Hanger
6. Once all the condensed water has been removed,
replace the rubber plug into the drain hole firmly.
The FullWater indicator should be off now.
4. Castors
9. Water Stopper (Rubber Plug Inside)
7. Replace the drain knob.
ByWater Tube (Continuous Drainage)
1. Remove the drain knob and rubber plug and keep them
for future use.
Accessories
10. Adaptor - for insertion over the
hose and into the back of the
air conditioner
2. Connect a suitable water tube
(of 3/4" internal diameter - supplied) to the water hole.
The condensed water will drain out automatically.
11. Exhaust Hose
3. If you want to extend the water tube you can connect
it with another tube (outside diameter 3/4").
12. Adjustable Slide Bar
13. Round Connector
14. Cap for Round Connector
15. Remote Control
Special Caution for Heating Function!
While using the heating function, please note:
1. Install the exhaust pipe securely in order to exhaust
the cool air to the outside (please see page 6).
2. Use the continuous drainage option as described above.
3. The warmer the outside air the more heat will be
pumped into the room. Working range for heat pump
function is 41°F to 81°F. When used in room temperatures
outside this range, the unit may not function properly.
4. While using the heating function during low temperatures,
sometimes the heating will stop for a while in order to melt the
internal frost. When this occurs, just wait for heating to resume.
This is normal for compressor operated devices.
4
9
Specifications
Troubleshooting
Model Number
Cooling Capacity
Heating Capacity (1)(2)
Power Consumption
Humidity Removal Capacity
Recommended room size*
Power Supply
ARC-12D
ARC-12H
12,000 BTU/hr
N/A
12,000 BTU/hr
12,000 BTU/hr
950W / 8.4A
65 Pts. / Day
400 sq. ft.
950W / 8.4A
65 Pts. / Day
400 sq. ft.
115V / 60Hz / 1 Phase
Rotary
115V / 60Hz / 1 Phase
Rotary
Compressor
Refrigerant
R-22
R-22
Fan Speed
2
2
Timer
1-12 hours
62°F - 90°F
65 lbs.
1-12 hours
62°F - 90°F
68 lbs.
Thermostat
NetWeight
Dimensions
16"W x 17"D x 30"H
Cooling: 62°F to 110°F
16"W x 17"D x 30"H
WorkingTemperature
Cooling: 62°F to 110°F
Heating: 41°F to 81°F
REMARKS:
1. The data may vary, please refer to the rating label on the back of the unit.
2. The above conditions are measured at:
Cooling - Indoor: RT 81°F, RH 60%
Heating - Indoor: RT 68°F, RH 60%
* Uninsulated rooms such as sunrooms, garages, or attics should be less than 400 sq. ft.
2
11
Table of Contents
THANK YOU...............................................................................................................................1
Energy SavingTips.........................................................................................................................................1..............
SPECIFICATIONS .......................................................................................................................2
BEFORE USE.................................................................................................................................3
PARTS
4
Front................................................................................................................................................................4................
Accessorie.s.....................................................................................................................................................4...............
INSTALLATION..........................................................................................................................5
Mounting the Uni.t........................................................................................................................................5..............
Mounting the Exhaust Pip.e..........................................................................................................................6............
Installation of the Carbon Filt.e..r................................................................................................................6............
OPERATION................................................................................................................................7
Control Pane..l................................................................................................................................................7...............
Turning On/O.f.f.............................................................................................................................................7...............
Setting Mode / Functio.n...............................................................................................................................7.............
Auto Mode......................................................................................................................................................7...............
Setting theTemperatur..e..............................................................................................................................7.........
Setting Fan Speed..........................................................................................................................................8..............
Setting theTime.r...........................................................................................................................................8..............
Regulating Airflow Directi.o..n.......................................................................................................................8............
DRAINAGE...................................................................................................................................9
By Draining into a Contain.e..r.....................................................................................................................9............
ByWaterTube (continuous drainag..e..)......................................................................................................9...........
MAINTENANCE........................................................................................................................10
Cleaning the Housin.g..................................................................................................................................1..0...........
Cleaning the Filte.r.......................................................................................................................................1..0............
End of Season Storage.................................................................................................................................1..0...........
Storing the Power Co..r.d............................................................................................................................1..0...........
TROUBLESHOOTING..............................................................................................................11
WARRANTY...............................................................................................................................14
13
|