Sony Ac Vq800 User Manual

English  
3-866-121-12(1)  
Thank you for purchasing the Sony AC adaptor/charger.  
Charging time  
The following table shows the charging time for the battery pack which is  
discharged completely.  
A
Specifications  
To Operate Video Equipment  
Before operating the unit, please read this manual thoroughly and retain it  
for future reference.  
Power requirements  
Power consumption  
100 - 240 V AC, 50/60 Hz  
25 W  
See illustration C.  
Use the nearest wall outlet in case a problem occurs and you need to  
unplug this unit.  
Use the supplied DK-415 or DK-215 connecting cord.  
For details of the connection, refer to the instruction manual of the video  
equipment.  
The AC-VQ800 AC adaptor/charger can be used as follows:  
To charge a lithium ion type battery pack. Ni-Cd/Nickel hydrogen type  
batteries are not rechargeable.  
The following functions are available with the InfoLITHIUM battery pack:  
– Quickly charging  
– Remaining charge time display  
Charge mode:  
35 VA (100 V AC), 50 VA (240 V AC)  
Operating mode:  
1
2
Battery pack  
Charging time  
Battery pack  
Charging time  
4
5
(InfoLITHIUM L series)  
(InfoLITHIUM M series)  
40 VA (100 V AC), 50 VA (240 V AC)  
DC OUT:  
AC Adaptor/Charger  
NP-F550  
NP-F750  
NP-F950  
115 (55)  
170 (110)  
225 (165)  
NP-FM50  
NP-FM70  
NP-FM90  
105 (45)  
150 (90)  
195 (135)  
Output voltage  
Application  
8.4 V, 2.0 A in operating mode  
Battery charge terminal:  
8.4 V, 1.4 A in charge mode  
Sony battery pack NP-FM50/FM70/FM90/  
F530/F550/F730/F750/F930/F950  
0°C to 40°C (32°F to 104°F)  
–20°C to 60°C (–4°F to 140°F)  
Approx. 136 × 48 × 90 mm (w/h/d)  
(5 / × 1  
including projecting parts  
Approx. 250 g (8.8oz)  
Connecting cord DK-415 (1), DK-215 (1),  
AC power cord (1)  
1
2
3
Set the mode change switch to VTR/CAMERA.  
Connect the power cord to a wall outlet.  
To enable the power supply to the video equipment with the house  
current, connection cords are included with this unit.  
6
7
3
Operating Instructions  
Mode d’emploi  
What is the “InfoLITHIUM”  
Connect the connecting cord A to the DC OUT connector of this  
unit.  
Approximate minutes to charge an empty battery pack fully (Full charge).  
Approximate minutes in parentheses indicate the time when you charge  
normally (Normal charge).  
To ascertain the battery life, refer to the instruction manual of the video  
equipment which you use.  
The charging time may differ depending on the condition of the battery  
pack or the temperature of the environment.  
The “InfoLITHIUM” is a lithium ion battery pack which can exchange data  
with compatible video equipment about its battery consumption. Sony  
recommends that you use the “InfoLITHIUM” battery pack with video  
Operating temperature  
Storage temperature  
Dimensions  
Manual de instrucciones  
4
Connect the connecting cord to the video equipment.  
equipment having the  
mark.  
1
10  
1
When using the connecting cord DK-415  
3
16  
/
2
× 3 / inches)  
(DCR-TRV9, etc.) (ill.C-1)  
8
qs  
qd  
Mass  
Supplied accessories  
While pressing the connecting plate B , slide it down.  
To remove the connecting plate, slide it up while pressing the battery  
release lever C.  
Notes  
WARNING  
VTR/CAMERA  
BATTERY LIFE  
When the mode change switch is set to VTR/CAMERA during charging,  
charging stops.  
WARNING  
TIME TO CHG  
NORMAL FULL  
9
0
To prevent fire or shock hazard, do not expose the unit to rain or moisture.  
qf  
qg  
When using the connecting cord DK-215  
(DCR-TRV10, etc.) (ill.C-2)  
Open the cover, and insert the connecting plug D.  
To remove the connecting plug, pull it out.  
Design and specifications are subject to change without notice.  
To avoid electrical shock, do not open the cabinet.  
Refer servicing to qualified personnel only.  
If the CHARGE lamp does not light or flash, check that the battery pack is  
correctly attached to the AC adaptor/charger. If it is not attached it will  
not be charged.  
h
m
Use a commercially available AC plug adaptor, if necessary, depending on  
the design of the wall outlet.  
qa  
Wall outlet  
AC power cord must be changed only at the qualified service shop.  
TM  
SERIES  
Notes  
When the CHARGE lamp flashes  
If a problem occurs during charging, the CHARGE lamp flashes and  
WARNING appears on the display.  
Check through the following chart.  
AC-VQ800  
For the customers in Canada  
If you set the mode change switch to CHARGE while operating the video  
equipment, the power supply to the video equipment stops.  
You cannot charge the battery pack attached to this unit while supplying  
the power to the video equipment.  
TM  
CAUTION  
AC plug adaptor  
SERIES  
B
TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO  
WIDE SLOT, FULLY INSERT.  
AC-VQ800  
Sony Corporation © 1999 Printed in Japan  
Keep this unit away from the video equipment if the picture is disturbed.  
This mark indicates that this product is a genuine  
accessory for Sony video products. When purchasing  
Sony video products, Sony recommends that you  
purchase accessories with this “GENUINE VIDEO  
ACCESSORIES” mark.  
Remove the battery pack from this unit, then install the same battery  
pack again.  
3
2
4
Notes on Use  
About the AC power cord plug  
The AC-VQ800 comes in two models, differentiated by the shape of the AC  
power cord plug.  
If the CHARGE lamp flashes  
again:  
Install another battery pack.  
If the CHARGE lamp lights and  
does not flash again:  
If the CHARGE lamp goes out  
because the charging time has  
passed, there is no problem.  
Identifying the parts  
Owner’s Record  
1
See illustration A.  
The model and serial numbers are located on the bottom of the unit.  
Record the serial number in the space provided below.  
Refer to these numbers whenever you call upon your Sony dealer  
regarding this product.  
Model  
Shape of the plug  
Polarized  
1 Terminal shutter (InfoLITHIUM L series)  
2 Terminal shutter (InfoLITHIUM M series)  
3 DC OUT connector  
4 CHARGE lamp  
5 Mode change switch  
If the CHARGE lamp flashes  
again:  
The problem is with this unit.  
If the CHARGE lamp lights and  
does not flash again:  
If the CHARGE lamp goes out  
because the charging time has  
passed, the problem is with the  
battery pack first installed.  
Model for USA/Canada  
Model for other countries  
Non polarized  
The model for USA and Canada: One blade of the plug is wider than the  
other for the purpose of safety and will fit into the power outlet only one  
way. If you are unable to insert the plug fully into the outlet, contact your  
dealer.  
Model No. AC-VQ800 Serial No.  
To remove  
1
6 DISPLAY CHANGE button  
7 Display window  
WARNING  
To prevent fire or shock hazard, do not  
expose the unit to rain or moisture.  
Display window  
8 InfoLITHIUM indicator  
9 WARNING indicator  
0 TIME TO CHG (charge) indicator  
qa Time indicator  
qs BATTERY LIFE (battery remaining time) indicator  
qd VTR/CAMERA indicator  
qf Full charge indicator  
qg Remaining battery indicator  
Please contact your nearest Sony dealer in connection with the product  
with the problem.  
About the remaining battery time  
While charging the battery pack, this unit will show the remaining battery  
time with your video equipment, etc. on the following conditions.  
Using the InfoLITHIUM battery pack  
Using the video equipment having the  
Make sure that you use the battery pack having the  
Consult the operating instructions supplied with your video equipment if it  
is applied to InfoLITHIUM.  
To remove the battery pack  
mark  
mark.  
NP-F550, etc. (ill. B-1)  
Slide the battery pack in the direction of the arrow, then lift it straight out.  
To remove  
2
NP-FM50, etc. (ill. B-2)  
Slide the battery pack in the direction of the arrow, then lift it straight out.  
Though the following models are applied to InfoLITHIUM, the  
remaining battery time is not displayed on this unit.  
DCR- SC100/SC100E/TRV7/TRV7E  
To Charge the Battery Pack  
To Check Charging  
While charging, you can check the charging time on the display. After  
starting charging in a minute, BATTERY LIFE lights up on the display.  
CCD-TR555/TR555E/TR610E/TR710/TR710E/TR760E/TR790E/TR810E/  
TR820E/TR825E/TR910/TR910E/TR920E/TR930/TR1100E/  
TR2200E/TR2300/TR2300E/TR3100E/TR3300/TR3300E/TR3400/  
TRV31/TRV31E/TRV41/TRV41E/TRV51/TRV51E/TRV54E/  
TRV56E/TRV61E/TRV62/TRV64E/TRV72/TRV81/TRV81E/  
TRV82/TRV91E/TRV94/TRV94E/TRV101/TRV101E/  
SC55/SC55E/SC65/SC65E  
See illustration B.  
1
2
3
Set the mode change switch to CHARGE.  
Connect the power cord to this unit.  
Press DISPLAY CHANGE while charging.  
Each time you press DISPLAY CHANGE, the display changes as follows.  
This symbol is intended to alert the user to the presence  
of uninsulated “Dangerous voltage” within the  
product’s enclosure that may be of sufficient magnitude  
to constitute a risk of electric shock to persons.  
Connect the power cord to a wall outlet.  
The beep sounds and the display window lights up.  
GV-A500/A500E  
The remaining battery time  
BATTERY LIFE  
when the battery pack being  
4
Install the battery pack.  
If you use the video equipment having the  
mark, the remaining battery  
charged is attached to your  
m
Charging begins. When the remaining battery indicator becomes  
and the CHARGE lamp lights up, normal charge is completed. For full  
charge, which allows you to use the battery slightly longer than “normal  
charge”, leave the battery pack attached until the CHARGE lamp goes  
out.  
time display of the battery pack being charged corresponds to the video equipment  
InfoLITHIUM video equipment  
having the  
mark which is last attached to the battery pack.  
The time is not displayed when the  
DISPLAY  
CHANGE  
This symbol is intended to alert the user to the presence  
of important operating and maintenance (servicing)  
instructions in the literature accompanying the  
appliance.  
remaining battery time is less than 5  
C
minutes.  
Charging  
Remove the battery pack when required. It can be used even if the  
charging is not completed.  
The remaining time until normal  
charge is completed  
Use only a lithium ion type battery pack. This unit cannot be used to  
charge a Ni-Cd/Nickel hydrogen type battery pack.  
Attach the battery pack firmly.  
2
TIME TO CHG  
CAUTION  
NORMAL  
m
m
Remaining battery indicator  
Charge the battery pack on a flat surface without vibration.  
You are cautioned that any changes or modifications not expressly  
approved in this manual could void your authority to operate this  
equipment.  
DISPLAY  
CHANGE  
Normal charge  
Full charge  
Charging temperature  
The remaining time until full  
charge is completed  
The temperature range for charging is 0°C to 40°C (32°F to 104°F).  
However, to provide maximum battery efficiency, the recommended  
temperature range when charging is 10°C to 30°C (50°F to 86°F).  
The Graphical Symbols with Supplemental Marking is located on the  
bottom of the unit.  
1
TIME TO CHG  
FULL  
h
DISPLAY  
CHANGE  
Note:  
2
Others  
To Install the battery pack  
This equipment has been tested and found to comply with the limits for a  
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits  
are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment generates, uses,  
and can radiate radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful interference to radio  
communications.  
However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference  
to radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
The nameplate indicating operating voltage, power consumption, etc. is  
located on the bottom.  
InfoLITHIUM L series (NP-F550, etc.) (ill. B-1)  
1 Place the battery pack on this unit with the b mark facing the  
terminal shutter (L series).  
2 Slide the battery pack in the direction of the arrow.  
Press the battery pack until the terminal shutter enters completely  
into this unit.  
Notes  
The negligible amount of electric current will flow into the AC adaptor/  
charger as long as the AC adaptor/charger is plugged into the wall outlet.  
Unplug the unit from the wall outlet if it will not be used for extended  
period of time. To disconnect the cord, pull it out by the plug. Never pull  
the cord itself.  
Do not operate the unit with a damaged cord or if it has been dropped or  
damaged.  
The time display shows the approximate time when charging at 10°C -  
30°C. The time display may differ from the actual charging time  
depending on using conditions and circumstances.  
The time display may show “– – – –” in the following cases. However, the  
unit is not malfunctioning.  
– The remaining battery time is less than 5 minutes.  
3
A
– There is a difference between the displayed time and actual charging  
time. Even if this happens, continue charging.  
Full charge requires about 1 hour after normal charge is completed. If you  
remove the battery pack between normal charge and full charge, the  
charging time may not be displayed properly in the next charging.  
If the charging time is not displayed properly, fully charge the battery  
pack. The charging time will be displayed properly.  
When you attach a fully charged battery pack to this unit, “TIME TO CHG  
FULL 1h” may appear on the display. However, this is not a malfunction.  
The remaining battery time may not be displayed depending on using  
conditions and circumstances of your video camera recorder and of the  
battery. See “About the remaining time” for more details.  
You may wait for a while after pressing DISPLAY CHANGE until the  
display shows the time indication.  
• To display the remaining battery time of a new battery, attach it to your  
video camera recorder and use it for about 20 seconds. Then, charge the  
battery with this unit.  
1
B
C
Be sure that nothing metallic comes into contact with the metal parts of  
the unit or connecting plate. If it does, a short may occur and the unit  
may be damaged.  
InfoLITHIUM M series (NP-FM50, etc.) (ill. B-2)  
1 Place the battery pack on this unit with the B mark facing the  
terminal shutter (M series).  
2 Slide the battery pack in the direction of the arrow.  
Press the battery pack until the terminal shutter lifts completely.  
Always keep the metal contacts clean.  
– Reorient or relocate the receiving antenna.  
Do not disassemble or convert the unit.  
Do not apply mechanical shock or drop the unit.  
While the unit is in use, it gets warm. But this is normal.  
Keep the unit away from AM receivers, because it will disturb AM  
reception.  
– Increase the separation between the equipment and receiver.  
– Connect the equipment into an outlet on a circuit different from that to  
which the receiver is connected.  
Note  
– Consult the dealer or an experienced radio/TV technician for help.  
When you install the battery pack, be sure to not strike it to the terminal of  
the AC adaptor/charger.  
Do not place the unit in a location where it is:  
— Extremely hot or cold  
NOTICE FOR THE CUSTOMERS IN THE UNITED KINGDOM  
A moulded plug complying with BS 1363 is fitted to this equipment for  
your safety and convenience.  
— Dusty or dirty  
— Very humid  
— Vibrating  
2
D
If any difficulty should arise, unplug the unit and contact your nearest Sony  
dealer.  
Should the fuse in the plug supplied need to be replaced, a 5 AMP fuse  
approved by ASTA or BSI to BS 1362, (i.e., marked with  
mark) must be used.  
or  
If the plug supplied with this equipment has a detachable fuse cover,  
be sure to attach the fuse cover after you change the fuse. Never use  
the plug without the fuse cover. If you should lose the fuse cover,  
please contact your nearest Sony service station.  

Samsung Aw2402m User Manual
Sanyo Twicell Hr 3uhs User Manual
Schumacher Inc 800a User Manual
Schumacher Se 3004 User Manual
Schumacher Ssc 1000a User Manual
Soleus Air Gm Wac 12ese C User Manual
Symbol Technologies Ls2208 User Manual
Whirlpool Amq062 User Manual
Xerox Wc5230 User Manual
York Sunline Magnadry Wr240 User Manual