Portable Air Conditioner and Heater
With Heat Pump Technology
PH3-09R-03 / PH3-10R-03
Operating Instructions
3046364
Model No. PH3-09R / PH3-10R
© 2006 Soleus Air International
PACKAGE CONTENTS
Portable Air Conditioner
Exhaust Hoses (1)
Hose Adapters (1)
Window Kit Adapter (1)
Remote Control
AAA Batteries (2)
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)
Owner’s Manual
SPECIFICATIONS
•
•
•
•
•
The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature,
the air conditioner may not work properly.
MODEL
PH3-09R-03
9,000 BTU/Hr
9,200 BTU/Hr
55 pts/day
1200 W
PH3-10R-03
10,000 BTU/Hr
10,500 BTU/Hr
60 pts/day
1256W
Cooling Capacity
Heating Capacity
Dehumidifying Capacity
Cooling
Power Consump-
tion
Heating
1050 W
1179W
Air Flow Volume
Power Source
285CFM
285CFM
115 V / 60 HZ
11.0 A
115 V / 60 HZ
11.5A
Cooling
Heating
Rated Current
9.5 A
10.8A
Sound Pressure Level
Weight
<45 db(A)
68.3lbs
<45 db(A)
68.3lbs
12.98” x 22.17”x 27.78”
12.98” x 22.17” x 27.78”
Dimensions (WxDxH)
Refrigerant
R22
R22
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE
PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
3
PRODUCT DIAGRAM (Actual product design may differ slightly from images below)
FRONT
A. Control panel
B. Vertical air louvers
C. Air outlet
D. Horizontal air louvers
E. Casters
F. Power Cord & Plug
BACK
A. Hot air outlet grill
B. Lower air inlet grill
ACCESSORIES
Flexible exhaust hose with 2 adapters
• 3-piece set
• stretches from 14 1/4” to 60 5/8”
(36cm to 150cm)
Adjustable window slider kit
• 3-piece set
• adjusts 33 1/2” to 70” (85cm to 177.8cm)
Drain tube
Drain pan
4
INSTALLATION
SELECTING THE LOCATION
Place the unit in a flat location where the air out-
lets are not obstructed. Place the unit at least
20” (50cm) away from a wall or other obstacle.
MOUNTING THE EXHAUST HOSE
Slide the square end of the exhaust duct over the
hot air outlet on the back of the unit.
The exhaust hose should be kept as short and
straight as possible. Prevent any sharp bends in
the exhaust hose, as this will trap hot exhaust air.
The hot exhaust air can be vented through the
wall or out a window. If mounting in the wall, the
height of the hole should be 16 to 50 inches
(40cm to 130cm).
Soleus Air does not provide a venting kit for
through the wall ventilation. Venting through the
wall requires a custom installation.
5
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord
with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk
of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must
be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed
metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting
recommendations.
RESET
TEST
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
6
WINDOW KIT INSTALLATION
WINDOW KIT INSTALLATION
The window kit is designed to fit into most standard
vertical and horizontal windows, as well as some
sliding glass doors. However, it may be necessary to
modify some aspects of the installation process for
certain window types.
Open the window or sliding door and adjust the
length of the window kit to fit the opening. If the
window kit is not long enough, connect the extra
window kit panel to fit the opening. Mark and cut
down a single panel of the window kit if neces-
sary.
Window Slider Kit
Minimum: 33 1/2” (85cm)
Maximum: 70” (177.8cm)
Place the window kit between the window and the
window frame as shown in the images to the right.
Close the window onto the window kit to form a
tight seal.
Attach the exhaust duct adapter to the window kit.
Tabs located on the adapter will lock into place
securing the adapter to the window kit.
Window Slider Kit
Minimum: 33 1/2” (85cm)
Maximum: 70” (177.8cm)
7
WINDOW KIT INSTALLATION (cont’d)
NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images
show general directions for all Soleus Air single hose portable air conditioners.
8
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS
CONTROL PANEL & MULTI-COLOR DISPLAY
MULTI-COLOR DISPLAY
A. Auto Mode
B. Cool Mode
C. Dehumidify Mode
D. Fan Mode
E. Heat Mode
F. Fan Speed (Low, High, Me-
dium)
G. Temperature
H. Swing Mode
I. Sleep Mode
J. Clock and Timer
K. Timer On
L. Timer Off
M. Compressor is on
9
OPERATING INSTRUCTIONS
CONTROL PANEL BUTTONS (Refer to the images on page 9)
1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER
button once more to turn the unit off.
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode,
Air Conditioner, Dehumidifier, and Fan.
3) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High,
Medium, and low. The fan speed can be visually distinguished by the speed of the digital air segments
progressing out from the windmill fan image on the Multi-color display. There is an additional auto speed
setting that is enabled in only heating and cooling modes. This speed is next setting after low when press-
ing the speed control button. The speeds will cycle through in this order: Low, Medium, High, Auto. Each
change in speed will be associated with a “beep” sound from the unit.
4) Temperature - Select the desired temperature by pressing either ▼ or ▲ button when using the unit in
cooling or heating mode. The temperature indicator flashes to display the desired temperature setting. After
the temperature is set, the unit will display this temperature setting until it is changed by the user. The
Multi-color display shows temperature in Celsius or Fahrenheit. Press the ▼ or ▲ buttons simultaneously
on the control panel to select the desired temperature setting.
5) Timer - To program the timer, press the TIMER ON button until the display shows a flashing “
”.
Press the ▲ or ▼ buttons to change the clock to the desired time for the unit to automatically turn on.
Press the TIME OFF button and the display on the unit will flash “
”. Press the ▲ or ▼ but-
tons to change the clock to the desired time for the unit to automatically turn off. The TIME OFF
indicator will flash for 3 seconds to activate your programmed on and off times.
6) Time Display - In the diagram on page 9, the letter “J” points to the adjustable time display. To adjust the
time, Press FAN SPEED and SWING together (at the same time). This will activate the time display fea-
ture. Next, let go of the FAN SPEED and SWING buttons, and press the ▲ button to adjust the hours, and
press ▼ to adjust the minutes.
7) Swing - To start horizontal oscillation, press the Swing button once. ‘‘
“ icon will appear on the
multi-color display. To stop oscillation, press the Swing button again. Vertical air flow direction can be
adjusted manually.
NOTE: The timer will remember your settings when it is set. If you set the timer while in Air Conditioning
mode, the timer will automatically turn the unit on and off in air conditioning mode according to the desired
programmed times. The timer will also remember the temperature settings, fan speed, and oscillation setting.
The timer works when the unit is in Air Conditioner mode, Dehumidifier mode, Fan mode, and Auto mode.
10
OPERATING THE UNIT USING THE CONTROL PANEL
Air Conditioner Mode
1) Install the exhaust hose and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER button on the control panel.
4) Press the Mode button until the “
” icon appears on the Multi-color display
5) Press the ▲ or ▼ buttons until the desired room temperature appears on the control panel
display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).
6) Select the desired fan speed by pressing the FAN SPEED button.
NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest
setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and
window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.
NOTE: When the unit is running on cooling mode, the exhaust hoses are required and must be vented outside
using the supplied window kit.
Dehumidifier Mode
1) Install the exhaust hoses and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER Button on the control panel.
4) Press the MODE button until the “
” appears on the control panel display.
NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly during
the dehumidification. Keep the windows and doors closed to aid the effectiveness of the unit in removing the
moisture from the room.
NOTE: When the unit is running in dehumidifier mode, the exhaust hoses are required and must be vented
outside using the supplied window kit. The unit will not perform in dehumidifier mode when the room tem-
perature is lower than 61°F .
Fan Mode
1) Plug the Power Cord into an electrical outlet.
2) Turn on the unit by pressing the POWER button on the control panel.
3) Press the MODE button until the “
” icon appears on the control panel display.
4) Select the fan speed by pressing the FAN SPEED button.
5) To circulate more air, press the SWING button on the remote control. The louvers will oscillate in our
exclusive WAVEFLO® pattern; back and forth and up and down, spreading more air throughout the
11
room.
NOTE: It is not necessary for the exhaust hoses and window kit to be installed to operate the unit in fan mode.
Heat Mode
1) Install the exhaust hoses and window kit properly (see pages 7 & 8).
2) Plug the power cord into a grounded outlet.
3) Turn on the unit by pressing the On/Off button on the control panel.
4) Press the Mode button until “
” icon appears on the multi-color display.
5) Press the Ù or Ú button until the desired room temperature appears on the multi-color display. The tem-
perature ranges from 61°F - 88°F (16°C - 31°C).
6) Select the fan speed by pressing the Fan button. It is recommended to use the low fan speed.
NOTE: When the unit is running on heating mode, the exhaust hoses are required and must be vented outside
using the supplied window kit.
Auto Mode
1) Install the exhaust hoses and window kit properly (see pages 7 & 8).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the
4) Press the MODE button until the “
by pressing the FAN button.
POWER button on the control panel.
” icon appears on the control panel display. Select the fan speed
NOTE: During AUTO mode, the unit operates in Heating mode when the room temperature is below 68 °F,
Dehumidifier mode when the room temperature is between 68 °F to 80 °F. And Air Conditioner mode when
the room temperature is above 80 °F.
Sleep Mode (This mode can only be selected when using the Remote control )
1) To set Sleep mode, make sure the unit is in Air Con-
ditioner mode.
2) Press the SLEEP Button on the remote control. The “
” icon appears on the control panel display.
3) When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.
4) When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above the original set
temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.
5) When in Heating mode, the temperature setting will gradually decrease to 2°F below the original set tem-
perature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.
6) When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.
12
Compressor Indicator
The “
” icon will light up on the control panel display when the compressor turns on. The “
” icon will
turn off when the compressor shuts off.
Emergency Condensate Holding Tank
When the unit is in cooling mode, unwanted water is extracted from the air. Most of this water is used to cool the unit
and make it run more efficiently. When the unit is used in extremely humid environments, water will collect in a water
container at the bottom of the unit. When the water container is full, the compressor will stop but the fan will continue to
run.
When the water container is full, the unit will display ‘
’ on the control panel until the tank is emptied. To resume
operation, empty the water container according to the following steps:
1. Turn the unit off. Do not move the unit when the water container is full.
2. Place the drain pan accessory under the drainage port at the back of the unit.
3. Remove the rubber plug from the drain hole. The condensate water will drain out automatically. When the drain pan
is full, replace the rubber plug into the drainage hole to stop the water flow. Empty the drain pan. Repeat until all the
water is emptied.
Once the water container has been emptied, replace the rubber plug into the drain hole firmly. Do not
allow the water to drip continuously into the drain pan, as it might easily overflow.
13
OPERATING THE UNIT USING THE REMOTE CONTROL
TIMER/TEMP INCREASE
REMOTE CONTROL
SWING (LOUVER
OSCILLATION)
MODE BUTTON
°C /°F BUTTON
FAN SPEED
SLEEP MODE
POWER BUTTON
TIMER BUTTON
TIMER/TEMP DECREASE
REMOTE CONTROL OPERATING INSTRUCTIONS
1) Power On and Off - Press the ON/OFF button on the remote to turn the unit on or off.
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto, Air
Conditioner, Dehumidifier, Fan only, and Heater mode.
3) Fan Speed - Press the FAN speed button to cycle through low, medium, and high fan speeds.
4) Temperature Setting - When the unit is in Air Conditioner mode you can select your desired tempera-
ture. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the multi-color
display on the control panel will increase or decrease accordingly. Pressing the °F/°C button will change
the temperature select between °F and °C.
5) Sleep Mode - See “SLEEP MODE” on page 12.
6) Swing - To turn on oscillation, press the SWING button on the remote control. Once you press SWING,
the louvers on the unit will oscillate back and forth.
7) Timer - To program the timer, press the TIMER button on the remote control. Press the ▲ or ▼ buttons
to change the clock to the desired time for the unit to automatically turn on. Press the TIMER button
again to set the time for the unit to shut-off. Press the ▲ or ▼ buttons to change the clock to the desired
time for the unit to automatically turn off. The TIMER OFF indicator on the multi-color display will
flash for 3 seconds to activate your programmed on and off times.
14
MAINTENANCE
Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to
performing any maintenance on the unit.
Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is
recommended to clean the filter once every two weeks or as needed.
1) Remove the filter from the filter compartment on the back of the unit.
2) Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter
and dry it thoroughly out of sunlight.
3) Slide the filter back into the filter compartment after it is thoroughly dried.
4) If the filter is torn or unusable, order a new filter by calling the customer service number on the
warranty page of this manual.
Clean the unit Housing
1) Keep the unit from being exposed directly to the sun to prevent color fading.
2) Clean the surface with a damp cloth and dry it with a soft towel.
Storing the Unit for an Extended Period of Time or Transporting the unit
1) Empty any excess water by unplugging the water drainage stop in the back of the unit (located at
the bottom).
2) Unplug the unit.
3) The unit should be stored in a cool dry place.
15
WARRANTY
One Year Limited Warranty
Soleus International Inc. warrants the accompanying Soleus Air PH3-09R-03 / PH3-10R-03 Portable Air Conditioner
with Heat Pump technology to be free of defects in material and workmanship for the applications specified in its op-
eration instruction for a period of ONE (1) year from the date of original retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of
charge within a reasonable time after the unit is returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a
copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
•
Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in
material or workmanship.
•
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions
in the instructions.
•
•
Damage to the finish of the case, or other appearance parts caused by wear.
Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-
tional Inc.
•
Freight and Insurance cost for the warranty service.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-
vaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights that vary from state to state.
For Technical Support and Warranty Service
Please Call (888) 876-5387
Or Write To:
Soleus International Inc.
9451 Telstar Ave.
El Monte, CA 91731 USA
16
|