SIZE: 19-1/4 in. (48.90 cm) H x 9-1/2 in. (24.13 cm) W x 9-1/2 in. (24.13 cm) D  
The Skuttle Make-Up Air Diffuser allows clean, fresh  
air to enter your home whenever there is a negative  
air pressure buildup or a need for replacement (make-  
up) air.  
(e.g., an exhaust vent, sewer vent, dryer vent or  
combustion outlet.  
3. Install the 6 in. (15.24 cm) flexible duct (not sup-  
plied) between the Diffuser and the inlet hood.  
NOTE: The Diffuser may be attached directly to the  
furnace cabinet. It may also be installed on a nearby  
wall or substantial support structure, but must be in-  
stalled within 1 ft. (30.48 cm) of the furnace cabi-  
net. (See diagram above.)  
NOTE: Flexible duct tubing is not supplied be-  
cause lengths vary greatly from home to home.  
4. Tape and seal all joints. Insulate the tubing in ar-  
eas where outdoor winter temperatures drop to  
32°F (0°C) or lower, or where water damage could  
occur.  
CAUTION: Be sure to follow all local codes and or-  
dinances.  
CAUTION: In homes with extreme negative pres-  
sures, the influx of cold outdoor air into the Diffuser  
may reduce temperatures in the surrounding area,  
possibly resulting in freezing conditions. In cold re-  
gions where this could occur, insulate plumbing  
or supply additional heat to the area.  
INSTALLATION INSTRUCTIONS  
1. Mount the Diffuser in a vertical position with the #8  
sheet metal screws provided.  
DANGER: Do not drill into electrical wiring or re-  
frigeration lines during installation.  
2. Select a location for the outside air intake vent. Cut  
the outside opening to allow room for a 6 in. (15.24  
cm) diameter duct to be installed.  
CAUTION: To prevent contaminated air from en-  
tering the inlet, make sure the Diffuser is at least  
10 ft. (3.05 m) from any discharge source  
Phone: 888-SKUTTLE (758-8853) or 740-373-9169  
© Skuttle Mfg. Co., 2008 • WEB-0756-251 • 4/08  

Mitsubishi Electronics Mitsubishi Digital Electronics Air Conditioner Muz Ana User Manual
Mitsubishi Electronics Msh 24nv User Manual
Savin 9965dp User Manual
Simplicity Sac8017ee User Manual
Toshiba Air Conditioner Rav Sm454mut Tr User Manual
Toshiba Air Conditioner Rav Sp804atzg E User Manual
Toshiba Carrier Rav Sp300ut Ul User Manual
Trion Cartridge Cleaning Systems User Manual
Whirlpool Acq122 User Manual
Xpelair 91174aa User Manual