OWNER’S MANUAL
Model 6000A
For 12-Volt Batteries
™
SpeedCharge
computer
smart
™
a m p
2C H A R G E 30C H A R G E
a m p
S
L
O
W
R A P I D
a m p
a m p
F
A
S
T
E N G I N E
S T A R T
C H A R G E
10
60
FullyAutomatic
Microprocessor Controlled
Battery Charger with
Engine Starter plus
Battery Tester and
Alternator Tester
CAUTION:
Read all Safety Rules and Operating Instructions,
and follow them with each use of this product.
Schumacher Electric Corporation
Mount Prospect, IL 60056 U.S.A.
Send Warranty Product Repairs to:
Customer Service Returns
P.O. Box 280,1025 E. Thompson, Hoopeston, IL 60942-0280
Questions? Call Customer Service: 1-800-621-5485
0099000399/0104
IMPORTANT SAFETY INSTRUCTIONS
WARNING – RISK OF EXPLOSIVE GASES
WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BAT-
TERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY
OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT
EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL
AND FOLLOW THE INSTRUCTIONS EXACTLY.
To reduce risk of battery explosion, follow these instructions and those published by
battery manufacturer and manufacturer of any equipment you intend to use in vicinity
of battery. Review cautionary marking on these products and on engine.
SAVE THESE INSTRUCTIONS
• WARNING: Handling the cord on this
product or cords associated with
accessories sold with this product, will
expose you to lead, a chemical known
to the State of California to cause
cancer and birth defects or other
reproductive harm. Wash hands after
handling.
• To reduce risk of electrical shock,
unplug the SpeedCharge from the
outlet before attempting any mainte-
nance or cleaning.
• Always charge battery in a well-
ventilated area.
• WARNING: Battery chargers get hot
during operation and must have
proper ventilation. Air needs to flow
around entire charger. Do not set
charger on flammable materials like
carpeting, upholstery, paper, card-
board, etc. Charger may damage
leather and melt plastic and rubber.
• Read all instructions and cautions
printed on the battery charger,
battery, and vehicle or equipment
using battery.
• Use charger only on lead-acid type
rechargeable batteries, such as those
used in cars, trucks, tractors, air-
planes, vans, RV’s, trolling motors,
etc. This charger is not intended to
supply power to a low voltage
HELP US HELP YOU ——
Remember:
Place charger as far away from the
battery being charged as the charger
cables will permit.
electrical system other than in a
starter-motor application.
• Never use charger for charging dry
cell batteries that are commonly used
with home appliances like radios,
stereos, remote controls, etc. These
batteries may burst and cause
personal injury.
Do not expose charger to rain or snow.
Never charge a frozen battery. If battery
fluid (electrolyte) becomes frozen, bring
battery into a warm area to thaw before
you begin charging.
Never allow battery acid to drip on
charger when reading specific gravity or
filling battery.
• Do not disassemble charger. Take it
to a qualified service professional if
service or repair is required. Incorrect
assembly may result in fire or
electrical shock.
Never set a battery on top of the
charger.
3
Never place charger directly above
battery being charged. The gases from
the battery will corrode and damage the
charger.
Be sure to position the charger power
cord to prevent it from being stepped
on, tripped over, or damaged.
Never pull out the plug by the cord
when unplugging the SpeedCharge.
Pulling on the cord may cause damage
to the cord or the plug.
Never touch the battery clamps together
when the charger is on. You could
cause a spark.
Never operate charger if it has received
a hard blow, been dropped, or otherwise
damaged. Take it to a qualified profes-
sional for inspection and repair.
Do not operate the SpeedCharge if it
has a damaged power cord or plug.
Have the cord replaced.
PERSONAL SAFETY PRECAUTIONS
• Wear complete eye and clothing
protection when working with lead-
acid batteries.
• Remove all personal metal items
from your body such as rings,
bracelets, necklaces and watches,
while working with a lead-acid battery.
A battery can produce a short circuit
current high enough to weld a ring (or
the like) to metal, causing a severe
burn.
• Make sure that someone is within
range of your voice to come to your
aid if needed while you work with or
are near a lead-acid battery.
• Have plenty of fresh water and
soap nearby for use in case battery
acid contacts your eyes, skin, or
clothing. If this happens, wash
immediately with soap and water.
Then get medical attention.
• Take care not to drop any metal tool
or metal object onto the battery. This
may spark or short circuit the battery
or another electrical device that may
cause an explosion.
• Always operate the battery charger in
an open, well-ventilated area.
• Avoid touching your eyes while
working with a battery. Acid particles
(corrosion) may get into your eyes. If
this occurs, flush eyes immediately
with running cold water for at least 10
minutes. Then immediately get
medical attention.
• Never smoke or allow a spark or
flame in the vicinity of the battery or
engine. Batteries generate explosive
gases.
• Neutralize any acid spills thoroughly
with baking soda before attempting to
clean up.
• Never charge a frozen battery.
4
BEFORE USING YOUR BATTERY CHARGER
It is important to understand the charger’s requirements. This section explains the
charger’s electrical requirements and how to prepare a battery for charging.
extension cord, please make sure that
you follow these guidelines:
PLUGGING IT IN
Your charger requires a 120V AC
receptacle installed according to all local
codes and ordinances.
• Make sure that pins on plug of
extension cord are the same number,
size, and shape as those of plug on
charger.
• Check that the extension cord is
properly wired and in good electrical
condition.
• Make sure that the wire size is large
enough for its length and for the AC
ampere rating, as specified in the
chart below.
MINIMUM RECOMMENDED EXTENSION CORD
USING AN EXTENSION CORD
The use of an extension cord is not
recommended. If you must use an
Length of Cord, in Feet
25 50 100 150
18 16 12 10
AWG* Size of Cord
*AWG=American Wire Gauge
PREPARING YOUR BATTERY TO BE CHARGED
It is important that you read and follow these guidelines while you are preparing to
charge the battery.
• Make sure that you have a 12 volt
lead-acid battery. Determine voltage
of battery by referring to vehicle
owner’s manual. Charge battery
initially at charger’s lowest rate.
• Take time to read all of the battery
manufacturer’s specific precautions,
such as removing or not removing
vent caps while charging, and
recommended rates of charge.
• Clean the battery terminals. Be care-
ful to keep corrosion from getting in or
around your eyes.
• Be sure that the area around the bat-
tery is well ventilated while it is being
charged. Gas can be forcefully blown
away by using a piece of cardboard or
other nonmetallic material as a fan.
• Wear safety glasses. See additional
“Personal Safety Precautions” on
page 4.
• If it is necessary to remove the battery
from the vehicle to charge it, always
remove the grounded terminal from
the battery first. Turn off all vehicle
accessories to avoid sparks from
occurring.
• For batteries with removable vent
caps, if required, add distilled water to
each cell until the battery acid reach-
es the level recommended by the
manufacturer. This will help purge
excessive gases from the cells. Be
careful not to overfill. If you have a
sealed battery with non-removable
vent caps, no action is necessary.
• NOTE: A marine (boat) battery
installed in a boat must be removed
and charged on shore.
5
OPERATING INSTRUCTIONS
IMPORTANT: Follow all safety instructions and precautions when charging your
battery. Wear complete eye protection and clothing protection. Charge your battery in
a well-ventilated area.
CHARGING BATTERY IN THE
VEHICLE:
heavy, unpainted metal part of the
chassis or engine block, away from
the battery (see figure above). DO
NOT connect clamp to negative
battery post, carburetor, fuel line or
sheet metal part.
1. Avoid personal injury by keeping
clear of fan blades, belts, pulleys and
other engine parts.
2. Avoid damaging the Charger by
keeping the power cord and output
cords away from the hood, door or
moving engine parts.
Connectingtoapositive-grounded
system: Connect the black (NEGA-
TIVE) output clamp to the NEGA-
TIVE post of the battery. Rock and
twist the clamp back and forth to be
sure a solid electrical connection is
made. Then connect the red (POSI-
TIVE) output clamp to a heavy,
unpainted metal part of the chassis
or engine block, away from the
battery. DO NOT connect clamp to
positive battery post, carburetor, fuel
line or sheet metal part.
3. Note the polarity of the battery posts
by checking the identification marks
on the battery: POSITIVE (POS, P or
+) and NEGATIVE (NEG, N or -). The
positive post is usually larger than
the negative post.
4. Identify which battery post is
grounded or connected to the
chassis. THIS IS NORMALLY THE
NEGATIVE POST.
6. Plug power cord into an AC outlet.
The charger will be set to the default
state of 2A charge rate and REGU-
LAR battery type (tester).
7. Press the appropriate control buttons
to select the desired charge rate and
battery type. Within a few seconds,
the CHARGING (yellow) LED should
light and the charging process should
start. If the CHECK (red) LED is on,
check for correct cable connections.
8. To disconnect the Charger, unplug its
power cord before attempting to
disconnect the output clamps. Then,
standing away from the battery,
remove the output clamp from the
chassis or engine block. Finally,
remove the output clamp from the
battery post.
NEGATIVE GROUNDED SYSTEM
5. Connecting to a negative-
grounded system: Connect the red
(POSITIVE) output clamp to the
POSITIVE post of the battery. Rock
and twist the clamp back and forth to
be sure a solid electrical connection
is made. Then connect the black
(NEGATIVE) output clamp to a
9. Clean and store the Charger in a dry
location.
6
7. To disconnect the Charger, unplug
its power cord before attempting to
disconnect the charger clamps. Then,
standing away from the battery,
remove the output clamp from the
NEGATIVE battery post. Finally,
remove the output clamp from the
POSITIVE battery post.
CHARGING BATTERY REMOVED
FROM THE VEHICLE:
POSITIVE
NEGATIVE
HARGER
BAT
POWER
CORD
8. Clean and store the charger in a dry
location.
TO
GROUNDED
POWER
USING ENGINE START
OUTLET
Your battery charger can be used to
jump start your car if the battery is low.
Follow these instructions on how to use
the ENGINE START feature.
1. Note the polarity of the battery posts
by checking the identification marks
on the battery: POSITIVE (POS, P or
+) and NEGATIVE (NEG, N or -). The
positive post is usually larger than
the negative post.
IMPORTANT: Follow all safety instruc-
tions and precautions when charging
your battery. Wear complete eye
protection and clothing protection.
Charge your battery in a well-ventilated
area.
2. Attach at least a 24-inch-long, 6-
gauge (AWG), insulated battery
cable to NEGATIVE (NEG, N or -)
battery post. Rock and twist the
clamp back and forth to be sure a
solid electrical connection is made.
IMPORTANT: Using the ENGINE
START feature WITHOUT a battery
installed in the vehicle could cause
damage to the vehicle’s electrical
system.
3. Connect the red (POSITIVE) output
clamp to the POSITIVE battery post.
Rock and twist the clamp back and
forth to be sure a solid electrical
connection is made.
1. With the charger plugged in and
connected to the battery of the
vehicle, set the CHARGE RATE to
60A START. Only the 60A START
and CHARGING LEDs (both yellow)
should be lit.
4. Position yourself as far away from
the battery as possible, and then
connect the black (NEGATIVE)
output clamp to the free end of the
cable.
2. Crank the engine for no more than 8
seconds. If engine does not start,
5. Plug the power cord into an AC
outlet. The charger will be set to the
default state of 2A charge rate and
REGULAR battery type (tester).
wait 2 minutes before cranking again.
3. After the engine starts, unplug the
power cord before disconnecting the
output clamps from the battery.
6. Press the appropriate control buttons
to select the desired charge rate and
battery type. Within a few seconds,
the CHARGING (yellow) LED should
light and the charging process should
start. If the CHECK (red) LED is on,
check for correct cable connections.
4. Clean and store the charger in a dry
location.
7
SPEEDCHARGE CONTROL
Charge
Rate
LEDs
Display
Mode
LEDs
Battery
Type
LEDs
™
SpeedCharge
Digital
LED
Status LEDs
Switch Buttons
6000A CONTROL PANEL
run down battery. Always use in
combination with a battery.
DISPLAY MODE SWITCH
Use this switch to set the function of the
digital LED to one of the following three.
• BATTERY %: The digital LED
displays an estimate of the percent of
charge of the battery connected to
the SpeedCharge battery clamps.
• VOLTAGE: The digital LED displays
the voltage at the SpeedCharge
battery clamps in DC volts.
BATTERY TYPE SWITCH
Use this switch button to set the type of
battery to be charged to one of the
following three.
• DEEP CYCLE: Deep cycle batteries
are usually marked as “deep cycle” or
“marine”. Deep cycle batteries are
usually larger than the other types.
• ALTERNATOR %: The digital LED
displays an estimate of the output of
the vehicle charging system con-
nected to the SpeedCharge battery
clamps as compared to a properly
functioning system.
• AGM, GEL CELL: AGM and gel cell
batteries have sealed cases without
vent caps. Such batteries are often
smaller than the other types.
• REGULAR: This is the type of battery
usually used in cars, trucks, and
motorcycles. These batteries have
vent caps and are often marked “low
maintenance” or “maintenance-free”.
CHARGE RATE SWITCH
Use this switch button to set the charge
rate to one of the following three.
• 2A CHARGE RATE: Intended for
charging small batteries such as
those commonly used in garden
tractors, snow mobiles and motor-
cycles. The 2A rate is not intended to
be used as a trickle charger for larger
batteries.
• 30Aꢀꢁ10A CHARGE RATE: Use for
charging automotive batteries,
marine batteries, and deep cycle
batteries. Not intended for industrial
applications.
With the exception of AGM and gel cell
batteries, all other battery types may or
may not have vent caps. Vent caps are
located on top of the battery and provide
a means to add distilled water when
needed. Batteries should be marked
with their type. If charging a battery that
is not marked, check the manual of the
item that uses the battery. If the battery
type is unknown, use the REGULAR
setting. Make sure the battery complies
with the safety instructions on page 3.
• 60A START: Provides 60 amps for
cranking an engine with a weak or
8
CONTROL PANEL GUIDE
l
,
l
e
C
l
e
G
M
G
A
e
l
c
y
C
-
p
e
e
D
R
6
r
a
l
u
g
e
t
r
a
t
S
A
0
A
0
1
A
0
3
A
2
%
r
o
t
a
n
r
e
t
l
A
V
B
C
C
C
e
g
a
t
l
o
a
h
h
h
%
y
r
e
t
t
k
c
e
a
a
g
n
i
g
r
d
e
g
r
9
USING THE BUILT-IN BATTERY TESTER
OVERVIEW
TESTINGAFTERCHARGING
The SpeedCharge has a built-in battery
tester that displays either an accurate
battery voltage or an estimate of the
battery’s relative charge based on the
battery voltage and the Battery Council
International scale.
After the unit has been changed from
tester to charger (by selecting a charge
rate), it remains a charger as long as it
has power. Disconnect and reconnect
the power to change the unit back to a
tester.
TESTING SEQUENCE
TESTERSTATUSLEDs
There are four basic steps required to
use the 6000A as a battery tester.
1. Connect the SpeedCharge battery
clamps to the battery. Be sure to follow
all of the precautions listed under
“OPERATING INSTRUCTIONS”.
2. Connect the SpeedCharge power cord
to a 120 VAC outlet. Again, be sure to
follow all of the precautions listed under
“OPERATING INSTRUCTIONS”.
3. If necessary, press the Battery Type
button until the correct type is indi-
cated.
When the 6000A is operating as a
battery tester, the status LEDs light
under the following conditions.
• The CHARGED (green) LED will light
if a charged battery is tested.
• The CHARGING (yellow) LED does
not light in the battery test mode.
• The CHECK (red) LED lights unless a
properly connected battery is de-
tected.
• When the tester display mode is set
to voltage, none of the Status LEDs
light (it could be testing a battery or
an alternator).
4. Read the voltage on the digital LED or
press the display mode button to set
the tester to “Battery %” and read the
battery percent.
INITIAL PERCENT CALCULATION
When a battery % is calculated for the
first time after connecting a battery, the
digital LED will show two dashes (“--”)
for a period as long as several seconds
while the tester analyzes the battery.
TESTER AND CHARGER
When first turned on, the 6000A oper-
ates only as a tester, not as a charger.
To continue to use it as only a tester,
avoid pressing the CHARGE RATE
switch button. Selecting a charge rate
activates the battery charger and
deactivates the tester.
NOTES FOR TESTING BATTERY %
A recently charged battery could have a
temporarily high voltage due to what is
known as “surface charge”. The voltage
of such a battery will gradually drop
during the period immediately after the
charging system is disengaged.
Consequently, the tester could display
inconsistent values for such a battery.
For a more accurate reading, the
surface charge should be removed by
temporarily creating a load on the
battery, such as by turning on lights or
other accessories.
POWER-UP IDLE TIME LIMIT
If no switch button is pressed within ten
minutes after the unit is first powered
up, the unit will automatically switch
from tester to charger, if a battery is
connected. In that case, the unit will be
set for the 2A charge rate and REGU-
LAR battery type.
TESTER WITHOUT TIME LIMIT
If either the DISPLAY MODE or BAT-
TERY TYPE button is pressed within the
first ten minutes after the unit is
powered up, the unit will remain a tester
(not a charger) indefinitely, unless a
charge rate is selected.
The battery % ranges from 0 to 100.
The battery tester is only designed to
test batteries. Testing a device with a
rapidly changing voltage could yield
unexpected or inaccurate results.
10
USING THE BUILT-IN ALTERNATOR TESTER
The SpeedCharge has a built-in
display mode button to set the tester
alternator tester that displays either an
accurate alternator voltage or an
to “Alternator %” and read the
alternator percent.
estimate of the alternator’s relative
output compared to normal alternators.
The Alternator % values displayed
should be taken as general reference,
not precise diagnosis. The alternator
tester functions the same as the battery
tester (see previous section of this
TESTERSTATUSLEDs
When the 6000A is operating as an
alternator tester, the status LEDs light
under the following conditions.
• The CHARGED (green) LED will light
if the output of the charging system is
at the normally desired level.
manual for details) with a few differences.
• The CHARGING (yellow) LED does
not light in the alternator test mode.
• The CHECK (red) LED lights if the
voltage is much higher or lower than
normally desired.
• When the tester display mode is set
to voltage, none of the status LEDs
light (it could be testing a battery or
an alternator).
TESTING SEQUENCE
There are three basic steps required to
use the 6000A as an alternator tester.
1. Connect the SpeedCharge battery
clamps to the battery or charging
system. Be sure to follow all of the
precautions listed under “OPERAT-
ING INSTRUCTIONS”.
2. Connect the SpeedCharge power
cord to a 120 VAC outlet. Again, be
sure to follow all of the precautions
listed under “OPERATING INSTRUC-
TIONS”.
ALTERNATOR TESTING NOTES
• The alternator percent display can
range from 0 to 199.
• The display mode cannot be set to
“Alternator %” during charging.
3. Start the vehicle and turn on the
vehicle’s headlights. Read the voltage
on the digital LED or press the
USING YOUR ENGINE STARTER
OVERVIEW
listed under “OPERATING INSTRUC-
TIONS”.
The 6000A has an engine start function
that can be used to jump start your
vehicle if the battery is low by providing
60 amps of current to assist engine
cranking.
3. Press the CHARGE RATE button
until the 60 START indicator is lit.
4. Crank the engine until it starts or 8
seconds passes.
STARTINGSEQUENCE
There are a few basic steps involved
when using the engine start function.
5. If the engine did not start, wait for the
SpeedCharge to cool then repeat
step 4.
1. Connect the SpeedCharge battery
clamps to the battery or charging
system. Be sure to follow all of the
precautions listed under “OPERAT-
ING INSTRUCTIONS”.
During the starting sequence listed
above, the charger is set to one of three
states.
1. Wait for cranking - The charger
waits until the engine is actually
being cranked before delivering 60
amps for engine start. The charger
delivers charge at a rate of 10 amps
2. Connect the SpeedCharge power
cord to a 120 VAC outlet. Again, be
sure to follow all of the precautions
11
while waiting and will reset if the
engine is not cranked within 10
display indicates the remaining cool
down time in seconds. It starts at 120
and counts down to 0. The 60A
START LED blinks once every
minutes. (If the charger resets, it sets
itself for a 2A charge and REGULAR
battery.) While waiting for cranking,
the digital display shows the battery
voltage (it can’t be set to percent).
second. During the cool down period,
the charger delivers charge at a rate
of 10A and the CHARGING LED is
lit. After 2 minutes, the 60A START
LED will stop blinking and will light
continuously, indicating that another
crank cycle can be started. The
digital LED will change from display-
ing the countdown back to displaying
the battery voltage.
2. Cranking - When cranking is
detected, the SpeedCharge will
automatically deliver up to its
maximum output (at least 60A) as
required by the starting system for up
to 8 seconds or until the engine
cranking stops. The digital display
shows a countdown of the remaining
crank time in seconds. It starts at 8
and counts down to 0.
ENGINE STARTING NOTES:
• When the 60A START rate has been
selected, the battery type selected
does not matter and no battery type
LED will be lit.
• If the battery is disconnected during
the cool down period, the charger will
reset.
3. Cool Down - After cranking, the unit
enters a mandatory 2-minute (120
second) cool down state. During this
period, no settings can be changed.
The buttons are ignored. The digital
USING YOUR BATTERY CHARGER
OVERVIEW
ABORTED CHARGE: If charging can’t
be completed normally, charging will be
aborted. When charging is aborted, the
charger’s output is shut off and the red
CHECK LED and digital LED blink on
and off (at opposite times). In that state,
the SpeedCharge ignores all buttons. To
reset from after an aborted charge,
either disconnect the battery or unplug
the charger.
Using the SpeedCharge battery charger
is very simple. First, connect the battery
and AC power following the precautions
listed under “OPERATING INSTRUC-
TIONS”. Then select the appropriate
BATTERY TYPE and CHARGE RATE
for your battery. The SpeedCharge will
then do everything automatically. This
section explains a few details.
CHARGING: If the charger does not
detect a properly connected battery, the
CHECK (red) LED will light continuously
until such a battery is detected. Charg-
ing will not begin while the CHECK light
is on. When charging begins, the
CHARGING LED will be lit.
DESULFATION MODE: If a battery is
left discharged for an extended period, it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch
to a special mode of operation designed
for such batteries. Activation of the spe-
cial desulfation mode is indicated by
blinking the CHARGING LED. If suc-
cessful, normal charging will resume af-
ter the battery is desulfated. The
CHARGING LED will then stop blinking
and light continuously. Desulfation could
take up to 10 hours. If desulfation fails,
charging will be aborted and the CHECK
(red) LED will blink.
AUTOMATIC SHUT OFF: When the 2A
or 30Aꢀꢁ10A charge rate is selected,
the charger is set to perform an auto-
matic charge. When an automatic
charge is performed, the charger stops
charging automatically after the battery
is charged.
12
30A CHARGE RATE: When set to
30Aꢀꢁ10A, the unit will charge the
battery for a few minutes at 10A. The
charger will determine whether to
increase the current to 30A, based on
factors including the battery voltage and
type selected. If the current is increased
from 10A to 30A, the 30Aꢀꢁ10A LED
will change from yellow to orange.
Eventually, the current will decrease
from 30A back down to 10A and the
LED will change from orange back to
yellow. The charge current may be
increased to 30A and decreased back
down to 10A several times during the
charging process. After the battery has
been charged enough for the display to
indicate 77%, the current will not be
increased to 30A.
MAINTAIN MODE: When the
CHARGED (green) LED is lit, the
charger has started Maintain Mode. This
mode of operation is also known as
Float-Mode Monitoring. In this mode,
the charger keeps the battery fully
charged by delivering a small current,
when necessary. The voltage is main-
tained at a level determined by the
BATTERY TYPE selected.
GENERAL CHARGING NOTES:
The unit is designed to control its
cooling fan for efficient operation.
Consequently, it is normal for the fan to
start and stop when maintaining a fully
charged battery. The fan does not run in
Tester Mode.
If the charge mode is changed after
charging has started (by pressing the
CHARGE RATE or BATTERY TYPE
button), the charging process will be
restarted.
COMPLETION OF CHARGING: Charge
completion is indicated by the
CHARGED (green) LED; when lit, the
charger has stopped charging and
switched to the Maintain Mode of
operation.
The voltage displayed during charging is
the charging voltage and usually will be
higher than the battery’s resting voltage.
CHARGING TIPS
Read this entire manual before using your charger. The tips below serve only as a
guide for specific situations.
If your vehicle won’t start: You don’t
need to fully charge a battery to start
your vehicle. If the charger won’t start
your vehicle using the 60A START rate,
try charging the battery using the
30Aꢀꢁ10A rate for 10 or 15 minutes.
That should charge the battery enough
to allow the 60A START rate to start the
vehicle. If the vehicle will then be
Reviving your battery: If you only wish
to charge your battery enough to
operate your vehicle, you don’t need to
wait for the entire charging process to
be completed. When the charger
displays a battery % of 77 or more (see
page 14), the battery has usually been
charged enough for the vehicle to start
and operate normally.
operated continuously for an extended
period (such as a long drive), the
vehicle could charge the battery back to
normal during that period. If the vehicle
will only be operated for a short period
(short drive), the battery might need to
be charged again before it could start
the vehicle again.
Completing an interrupted charge: If
the charging process has been inter-
rupted and restarted after the charger
displays a battery % of 85 or more, the
charger could go straight to Maintain
Mode (see top of this page). However, if
the original charge was started using
30Aꢀꢁ10A, the charge can often be
completed using the 2A rate.
13
BATTERY PERCENT AND CHARGE TIME
This charger adjusts the charging time
There are some important facts to keep
in order to charge the battery com-
pletely, efficiently and safely. The
microprocessor automatically makes
the necessary decisions. However, this
section includes guidelines that can be
used to estimate charging times.
in mind when charging a battery.
• When the display indicates 77%
charged, the battery has been
charged enough to start most vehicles
and has already been charged as
much as by many other battery
chargers.
The duration of the charging process
depends on three factors:
• When the display indicates 85%
charged, the battery has already been
charged at least as much as by most
other battery chargers.
1. Battery State – If a battery has only
been slightly discharged, it can be
charged in less than a few hours. The
same battery could take up to 10
hours if very weak. The battery state
can be estimated by using the built-in
tester (see page 10). The lower the
reading the longer charging will take.
• The battery % shown in tester mode
is an estimate based on the battery
voltage and the Battery Council
International scale. The battery %
shown in charger mode is an estimate
of the relative charge in the battery
compared to the charge it should
have if the charging process is
allowed to complete.
2. Battery rating – A higher rated
battery will take longer to charge than
a lower rated battery under the same
conditions. A battery is rated in
ampere-hours (AH), reserve capacity
(RC) and cold cranking amps (CCA).
The lower the rating the quicker the
battery will be charged.
• The battery % shown in tester mode
can be used to estimate the relative
charge time. The lower the % shown,
the longer the charge time. The lower
the % shown, the longer the charge
time for a given battery.
3. Charge rate – The charge rate is
measured in amps. This charger
provides charge rates of 2A and
30Aꢀꢁ10A. The 60A rate is for
• The battery % shown in charger mode
is an indication of the relative
progress of the charging process. The
higher the battery % displayed, the
less charge time remains.
engine start only. The 2A rate is for
charging smaller batteries such as
those used for motorcycles and
garden tractors. Such batteries
should not be charged using the
30Aꢀꢁ10A rate. The 30Aꢀꢁ10A rate
is for charging larger batteries. The
6000A charges at the selected
charge rate and eventually reduces
the charge rate in a controlled
• The more a battery is discharged, the
faster it absorbs charge from a
charger. That means that the battery
% increases faster at the beginning of
the charging process than at the end.
In other words, it takes longer for the
battery to absorb the last few percent
of charge than the first several
percent.
manner. After the charging process
has started, the digital display can be
used to determine charging progress
by selecting the BATTERY % mode.
14
TROUBLESHOOTING
Performance problems often can be corrected by the user. Please read through this
chart for a possible solutions to common problems.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The battery is connected
and the charger is on,
but it isn’t charging.
The SpeedCharge is in
tester mode, not charger button to activate charging
mode.
Press the CHARGE RATE
and select a charge rate.
Indicator lights are lit in an The charger may be
Return to place of pur-
chase for replacement.
erratic manner not
explained in the “Using
Your Battery Charger”
section.
defective.
You might have
Make sure nothing is
accidentally activated a
touching the control panel,
special diagnostic mode. then unplug the unit and
plug it in again.
The CHECK (red) light
This will happen if the
Reset the charger by un-
always flashes before the battery did not reach full plugging it or briefly
battery is completely
charged.
charge within 24 hours.
May be due to a very
disconnecting it or briefly
disconnecting the negative
large battery or a bank of battery clip. Select the
batteries requiring more desired charge rate and
power than a 30/10 Amp battery type again, if
charger can deliver within necessary.
24 hours. The battery
may also be faulty.
Engine crank time is less
than specified.
Starter motor may be
drawing more than 60
Amps.
Charge the battery at the
30Aꢀꢁ10A rate for 10 to
15 minutes then crank the
engine.
The green CHARGED
light turns on a few
minutes after connecting
to the battery.
The battery may be fully
charged or recently
charged, leaving the
battery voltage high
enough to appear to be
fully charged.
If the battery is in a vehicle,
turn the headlights on for a
few minutes to reduce the
battery voltage and try
charging again.
MAINTENANCE AND CARE
A minimal amount of care can keep your battery charger working properly for years.
1. Clean the clamps each time you are finished charging. Wipe off any battery fluid
that may have come in contact with the clamps to prevent corrosion.
2. Coil the input and output cords neatly when storing the charger. This will help
prevent accidental damage to the cords and charger.
3. Occasional cleaning of the case of the charger with a soft cloth will keep the finish
shiny and help prevent corrosion.
15
LIMITED WARRANTY
SCHUMACHER ELECTRIC CORPORATION,
801 BUSINESS CENTER DRIVE,
MOUNT PROSPECT, ILLINOIS 60056-2179
MAKES THIS LIMITED WARRANTY TO THE ORIGINAL PURCHASER AT RETAIL
OF THIS PRODUCT. THIS LIMITED WARRANTY IS NOT TRANSFERABLE.
Schumacher Electric Corporation warrants this battery charger for five years from
date of purchase at retail against defective material or workmanship. If such should
occur, the unit will be repaired or replaced at the option of the manufacturer. It is the
obligation of the purchaser to forward the unit together with proof of purchase,
transportation and/or mailing charges prepaid to the manufacturer or its authorized
representative.
This limited warranty is void if the product is misused, subjected to careless handling,
or repaired by anyone other than the manufacturer or its authorized representative.
The manufacturer makes no warranty other than this limited warranty and expressly
excludes any implied warranty including any warranty for consequential damages.
THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER
NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY
OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS
LIMITED WARRANTY. THE MANUFACTURER MAKES NO WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PURPOSE OF THIS PRODUCT AND
EXPRESSLY EXCLUDES SUCH FROM THIS LIMITED WARRANTY.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDEN-
TAL OR CONSEQUENTIAL DAMAGES OR LENGTH OF IMPLIED WARRANTY SO
THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
WARRANTY VALIDATION: The enclosed “Warranty Validation Card” must be
completed and mailed within 10 days of product purchase to activate this limited
warranty.
16
|