Sanyo 42tw72r User Manual

Print Form  
Split System Submittal Data  
System: 42TW72R  
Indoor/Outdoor: THW4272R/C4272R  
Ceiling Suspended Air Conditioner  
Job Name:  
Location:  
Approval:  
Date:  
Engineer:  
Construction:  
Unit #:  
Drawing #:  
Submitted to:  
Submitted by:  
Reference:  
General Data (at 230V)  
Power  
Circuit Ampacity  
Fuse Size, Max.  
V/PH/Hz  
(A)  
(A)  
230/208/1/60  
15-40 Indoor-Outdoor  
15-40 Indoor-Outdoor  
Refrigerant  
Lbs. - R410a (outdoor unit)  
Control  
R410A  
7.94  
Electric Expansion Valve  
Compressor  
No. used  
R.L. Amps - L.R.  
Crankcase Heater  
DC Rotary Inverter  
1
18.1-31.0  
-
Flare  
165  
Connection  
(A)  
(W)  
Line Length, Max  
Lift Difference, Max  
Line Size  
50 (Outdoor lower), 100 (Outdoor higher)  
Outdoor Unit  
Fan type  
Dia. (in.) - No. Speeds  
Type Drive - No. Speeds  
No. Poles  
(in. O.D. Discharge)  
(in. O.D. Suction)  
3/8”  
5/8”  
Line Size  
Propeller  
18-7/64-2  
Direct Inverter  
8 - 830  
Dimensions  
(in.)  
H x W x D  
Indoor Unit  
(RPM)  
(W)  
(Uncrated)  
(Crated)  
9-7/16 x 62-1/32 x 26-3/8  
12-15/32 x 66-1/16 x 31-1/6  
48-7/16 x 37 x 13-3/8  
No. Motors  
2-90  
(High)  
3531  
CFM  
Outdoor Unit  
(Uncrated)  
(A)  
19.7  
F.L. Amps  
(Crated)  
52-3/8 x 39-31/32 x 16-3/32  
Aluminum Fin & Copper Pipe  
Coil Type  
Weight  
Net  
Shipping  
Indoor  
84  
Outdoor  
220  
Slit Plate - Inner Rifed  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
(lbs.)  
(lbs.)  
2-12.7  
11.62  
3/8”  
97  
240  
(sq.ft.)  
(in.)  
Tube Size  
Indoor  
14.8  
Outdoor  
19.5  
Shipping Volume  
(cu.ft.)  
Indoor Unit  
Fan type  
Dia. & Length (in.) - No. Speeds  
No. Speeds  
No. Poles  
No. Motors  
Performance Data @ ARI Standard Conditions (230V)  
Cooling  
Centrifugal  
5-29/32 - 4  
3 & Auto  
Total Capacity  
Sensible Capacity  
Latent Capacity  
SEER  
(BTU/H)  
(BTU/H)  
(BTU/H)  
39,000 (9,500-39,000)  
(RPM, High)  
(W)  
(HI/Med/Lo)  
4-1099  
1-100  
1130/950/775  
23,560  
15,440  
15.6  
CFM  
Indoor Sound Rating  
F.L. Amps  
Dehumidification  
Amps  
(Pints/H)  
(A)  
12.6  
21.1/23.3  
(Hi) (dB-A)  
(A)  
44  
0.8  
Power Inputs  
Outdoor Sound Rating  
(W)  
4,140/4,140  
53  
Coil Type  
Aluminum Fin & Copper Tube  
(dB-A)  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
Slit Plate - Inner Rifed  
3-14.9  
3.51  
(sq.ft.)  
Tube Size  
Drain Connection Size  
(in.)  
(in.)  
9/32”  
(1-1/4)  

Panasonic Cu E21cke User Manual
Plh Products Geappliances G158 User Manual
Roland Automobile Parts Cy 5 User Manual
Samsung As12hpbn User Manual
Sanyo 12khs71 User Manual
Thomas Betts 20 User Manual
Universal All Pro 100r Ng User Manual
Whirlpool X12002v0 User Manual
York 145 Seer Tcgf60 User Manual
York Dh 180 User Manual