F565373
Operating Instructions
Air Conditioner
POWE
R
TIM
ER
QU
IET
POW
ERFUL
CS-E24FKR
CS-E28FKR
CU-E24FKR
CU-E28FKR
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Manufactured by:
© 2006 Panasonic HA Air-Conditioning (M) Sdn Bhd
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site,
40300 Shah Alam, Selangor, Malaysia.
REGULATORY INFORMATION
■ Operation Condition
The appliance is not intended for use by young children or the infirm person without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Use this air conditioner under the
following temperature range.
Indoor
Temperature (°C)
Environmental Reeqquuiirreemmeennttss
*DBT *WBT
Maximum
Minimum
Maximum
Minimum
32
16
30
16
23
11
–
COOLING
HEATING
Battery Disposal
The batteries must be recycled or disposed of properly.
–
Outdoor
Temperature (°C)
Maximum
End-oof-Liffe Disspposal
*DBT *WBT
43
16
24
-5
26
11
18
-6
COOLING
Minimum
Maximum
Minimum
HEATING
“Instructions for end-user” for air conditioners:
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact
your installer, dealer or local authority and ask for the correct method of disposal.
Note:
The illustrations in this manual
are for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice for
future improvement.
3
PRODUCT OVERVIEW
■ About
Remote Control Preparation
Air intake
Indoor Unit
1. Pull out
the cover.
Supersonic air
purifying device
Front panel
Auto OFF/ON
button
2. Insert AAA or R03
batteries.
Receiver
3. Close the cover.
4. Press CLOCK.
Air filter
TIMER
ON
5. Press to
set time.
SET
3
1
2
Indicator
Airflow direction
louver
OFF
CANCEL
AC
RC
SET CHECK
CLOCK
RESET
6. Press again.
Discharged air
• Timer operation will be based on
current time set.
Outdoor Unit
• The batteries can be used for
approximately 1 year.
Air inlet (rear)
Remote Control Signal
• Make sure it is not obstructed.
• Maximum distances : 10m.
Air inlet (side)
• Certain fluorescent lights may
interfere with signal transmission.
Please consult your nearest dealer.
Air outlet
Auto OFF/ON Button
Remote Control
Transmitter
Action
Press once.
Mode
Automatic
Press and hold until
you hear one beep,
then release.
Cooling
LCD display
Press until you hear
one beep then release.
Press again until you
hear two beeps then
release.
Off/On
Operation mode
Quiet operation
Powerful operation
Heating
Temperature setting
Fan speed selection
Airflow direction
adjustment
• To turn off, press the AUTO OFF/
ON button again.
Timer setting
Clock setting
Check
* For normal operation, the and reset buttons are not in use.
* Press reset to restore the remote control’s default setting.
Troubleshooting
● In the event of an error, the unit will stop and the timer indicator will blink.
2. Press until you hear beep
sound, then jot down the
error code.
Notes:
1. Press for 5 seconds.
• The unit may be operable (with 4 beeps)
on a limited basis, depending on the error.
TIMER
ON
SET
3
3. Press for 5 seconds to quit
checking.
1
2
OFF
CANCEL
AC
RC
4. Turn the unit off and reveal the
error code to your nearest dealer.
SET CHECK
CLOCK
RESET
4
AUTO, HEAT, COOL, DRY
■ Operation Details
AUTO - Automatic Operation
• Unit selects the operation mode
according to temperature setting,
outdoor and room temperature.
• The power indicator blinks during
operation.
• Operation mode is reselected
every 30 minutes.
HEAT - Heating Operation
• In heating mode, it takes a while
for the unit to warm up. The
power indicator blinks during this
operation.
FAN
SPEED
AUTO
HEAT
COOL
DRY
AIR
SWING
OFF/ON
COOL - Cooling Operation
MODE
2
• Enjoy cool air at your desired
temperature.
1
OFF/ON
MODE
Start the
operation.
DRY - Soft Dry Operation
• Keeps your environment
dehumidified by running a very
gentle cooling operation.
Select the
desired
operation.
QUIET
TEMP
POWERFUL
FAN SPEED
• During soft dry operation, the
indoor fan operates at low fan
speed.
AIR SWING
TIMER
ON
4%-0
SET
3
3
1
2
Set the
temperature.
(16°C~30°C)
OFF
CANCEL
■ Hint
AC
RC
• A temperature setting 1°C higher
in cooling operation or 2°C lower in
heating operation than the desired
temperature equates to a 10%
power saving.
SET CHECK
CLOCK
RESET
● Supersonic air purifying device operates automatically once
the unit is switched on.
and QUIET operations are available in all modes.
POWERFUL
●
OFF/ON
● Press
again to stop the operation.
Troubleshooting
● Mist emerges from indoor unit.
► Condensation effect due to cooling process.
► Ensure temperature is set correctly.
● Heating/Cooling operation does not work.
► Make sure windows and doors are closed.
► Make sure filters are cleaned and replaced.
► Make sure inlet and outlet vents are cleared.
● Water flowing sound during operations.
► Cause by refrigerant flow inside the unit.
● The power indicator blinks during the operation and
► The unit is in defrost mode, and the melted frost is drained from the
the indoor fan is stopped.
outdoor unit.
5
FAN SPEED, AIR SWING
■ Operations Details
FAN SPEED
• There are 5 fan speeds, as well as
automatic*.
* For automatic fan speed, the
speed of the indoor fan is
automatically adjusted according
to the operation.
FAN SPEED
AIR SWING
AIR SWING
• Keeps the room ventilated.
FAN
SPEED
AUTO
HEAT
COOL
DRY
• There are 5 options for vertical/
horizontal airflow direction.
Select fan
speed.
AIR
• Do not adjust the vertical and
horizontal louvers by hand.
SWING
Adjust the
airflow
direction
louver.
OFF/ON
MODE
• If automatic vertical airflow direction
has been set, the louvers swing up
and down automatically.
QUIET
TEMP
POWERFUL
FAN SPEED
• For HEATING operation, the air
blows horizontally for a while, then
starts to blow downwards.
AIR SWING
TIMER
ON
SET
3
1
2
• If automatic horizontal airflow
direction has been set, the louvers
swing left and right automatically.
OFF
CANCEL
AC
RC
• For HEATING operation, the airflow
louvers start to swing left/right after
the temperature rises.
SET CHECK
CLOCK
RESET
Troubleshooting
● The room has a peculiar odour.
► This may be a damp smell emitted by the wall, carpet, furniture or
clothing.
● Indoor fan stops occasionally during automatic fan
► This helps to remove the surrounding odours.
speed setting.
● Indoor fan stops occasionally during heating
► To avoid unintended cooling effect.
operation.
6
POWERFUL, QUIET
■ Operation Details
POWERFUL
• To reach the desired set
temperature quickly.
QUIET
QUIET
• To provide a quiet surrounding
Enables
quiet
operation.
FAN
SPEED
AUTO
HEAT
COOL
DRY
AIR
SWING
■ Hint
• To reduce power consumption
during cooling operation, close the
curtains to prevent the sunlight and
heat from coming in.
OFF/ON
MODE
QUIET
TEMP
POWERFUL
FAN SPEED
AIR SWING
TIMER
ON
SET
3
POWERFUL
1
2
OFF
CANCEL
Enables
powerful
operation.
AC
RC
SET CHECK
CLOCK
RESET
POWERFUL
QUIET
QUIET
●
●
and
operations could not be activated at the
operations could be cancelled by pressing
same time.
POWERFUL
and
the respective button again.
Troubleshooting
● Noisy during operation.
► The unit may have been installed at an incline, or the front panel is not
closed properly.
► The delay is a protection to the unit’s compressor.
● Operation is delayed a few minutes after restart.
► Condensation or evaporation occurs on pipes.
● Outdoor unit emits water/steam.
7
TIMER
■ Operation Details
• The timer allows you to turn the air
conditioner on or off automatically.
• The unit may start in preliminary
operation before the actual set time
when ON timer has been set.
• The set timer repeats daily once
set.
• If there is a power failure, you can
restore the previous setting (once
power is resumed) by pressing the
SET
button.
1
SET
FAN
SPEED
AUTO
HEAT
COOL
DRY
• If the timer is cancelled, press
to restore the previous setting.
AIR
Select ON or
OFF timer.
2
SWING
2
Set the
OFF/ON
MODE
■ Hints
• Press and hold the
desired time.
QUIET
for
CLOCK
approximately 5 seconds to set
either 12-hour (am/pm) or 24-hour
time indication.
TEMP
POWERFUL
FAN SPEED
• To dim the indicator display:
3
AIR SWING
TIMER
ON
SET
3
Confirm the
setting.
1
2
Press and hold for
5 seconds.
OFF
CANCEL
TIMER
AC
RC
ON
SET
3
To cancel, press
the again for
5 seconds.
SET CHECK
CLOCK
1
2
RESET
CANCEL
OFF
CANCEL
Cancel the
selected timer.
AC
RC
SET CHECK
CLOCK
RESET
• To switch the temperature setting
to °C or °F, press and hold
for approximately 10 seconds.
● The timer is valid only when the clock is set correctly.
● You can set your preferred time for ON and OFF timers.
The unit will turn ON or OFF automatically.
/.
● To cancel ON or OFF timer, press
press
or
, then
OFF
.
#!.#%,
Troubleshooting
● Timer indicator always on.
● Remote control does not work.
● The unit does not work.
► The timer setting repeats daily once set.
► The batteries are inserted incorrectly or need replacing.
► The circuit breaker is tripped or the timer is set incorrectly.
● Power indicator blinks before the unit is switched on. ► This is a preliminary step in preparation for the operation when the ON
timer has been set.
8
CARE & CLEANING
■ Washing Instructions
• Do not use benzene, thinner or
scouring powder.
Switch ooff tthhee ppoowweerr ssuuppppllyy
before cleaning
• Use only soaps ( pH7) or neutral
≃
household detergent.
• Do not use water hotter than 40°C.
FRONT PANEL
INDOOR UNIT
Raise and pull to remove.
• Wipe the unit gently with a soft, dry
cloth.
Wash and dry.
AIR FILTER
AIR FILTER
Vacuum, wash and dry.
• Air filters cleaning is needed every
two weeks.
• Replace any damaged filter.
Part no: CWD001137
CWD001138
SUPER ALLERU-BUSTER AND
DEODORIZING FILTERS
Remove
• It is recommended to vacuum the
filters every 6 months.
• For best perfomance, place the
deodorizing filter under direct
sunlight for at least six hours every
six months.
Remove
• Replace the filter every 3 years or
replace any damaged filters.
Part no: CZ-SAD13P
INDOOR
UNIT
SUPERSOONIC AIR
PURIFYINGG DEVICE
Wipe gently.
■ Hints
• Clean the filter regularly for best
performance and to reduce power
consumption.
• Please consult your nearest dealer
for seasonal inspection.
Remove
Vacuum the super
alleru-buster filter.
Vacuum the deodorizing
filter and place under
direct sunlight.
Vacuum, wash and
dry the frame.
■ For extended non-use
• Activate heating for 2~3 hours to thoroughly dry the unit.
• Turn off the power supply.
• Remove the remote control batteries.
9
SEASONAL INSPECTION AFTER EXTENDED NON-USE:
• Checking of remote control batteries.
• No obstruction at inlet and outlet vents.
• After 15 minutes of operation, it is normal to have the following temperature difference between inlet and outlet vents:
Cooling: ≥ 8°C
Heating: ≥ 14°C
10
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions:
• Abnormal noise during operation
• Water/foreign particles have entered the Remote Control
• Water leak from Indoor unit
• Circuit breaker switches off frequently
• Power cord becomes unnaturally warm
• Switches or buttons are not functioning properly
11
Printed in Malaysia
OPSC0606-01
Matsushita Electric Industrial Co., Ltd.
F565373
|